K. TE_05_Gas Systems_OMA_W912PB26RA011.xlsx

XLSX spreadsheet 25 KB Posted

Attached to
Inspection, Maintenance and Repair Work on Fire Extinguisher Systems at USAG Bavaria, Germany
Solicitation number
W912PB26RA011
Issued by

About this file

This is an inventory and equipment specifications document for gas-based fire suppression systems located at multiple U.S. Army installations in Bavaria, Germany, specifically supporting the solicitation W912PB26RA011 for maintenance, inspection, and repair services.

The document details gas fire extinguisher and suppression system inventories across three military installations: Rose Barracks in Vilseck, Tower Barracks in Grafenwoehr, and Hohenfels. Systems documented include Minimax and Tyco nitrogen-based units with specifications such as agent capacity (ranging from 3 to 18 cylinders of 80-140 liters each), blowing agent quantities, spray nozzles, manual release mechanisms, alarm horns, and detection components. Equipment is tracked with manufacturer information, serial numbers, build years (primarily 2020-2023), battery specifications (predominantly 12V 18Ah or 24Ah units with manufacture years noted), and maintenance history including extinguishing agent replacement dates and scheduled future maintenance intervals. Additional system components documented include pressure reducers, discharge hoses, check valves, flow switches, sprinkler systems (both wet and dry types), foam and pressurized water storage containers with capacity ratings, pumps with flow rate specifications, compressors, and alarm bells. The inventory identifies fire suppression infrastructure with pipe diameter specifications (DN80-DN200), temperature thresholds, and pressure switch ratings. This baseline inventory data supports the upcoming IDIQ contract for inspections, maintenance, and repair services with a Period of Performance beginning August 1, 2026.

View the file

Other files

File Type Posted
4.4_Attachment 04_OperatManual_Wagner.pdf PDF
4.7_TE_06_Spark Ex_7.6_revised (6Jul26).xlsx XLSX spreadsheet
4.5_Attachment 05 - Manufacturer Guide_GAMA-tronik Kitchen.pdf PDF
4.6_TE_05_Gas Systems_OMA_revised (6Jul26).xlsx XLSX spreadsheet
4.3_Attachment 01 - CLS_411_revised_24JUN.docx DOCX document
4.8_TE_07_Sprinkler_6.7-9.7_revised (30Jun26).xlsx XLSX spreadsheet
4.1_4th Amendment W912PB26RA0110004 SF 30 (2).pdf PDF
4.9_ELIN Sheet_W912PB26RA011_8_6Jul26.xlsx XLSX spreadsheet
4.2 _Vendor Questions - Answers.pdf PDF
Solicitation 3rd Amendment W912PB26RA0110003 SF 30.pdf PDF
Solicitation 2nd Amendment W912PB26RA0110002 SF 30.pdf PDF
S. Site Visit invitation_W912PB26RA011.pdf PDF
S. Solicitation 1st Amendment W912PB26RA0110001 SF 30.pdf PDF
L. TE_06_Spark Extinguishing System_OMA_W912PB26RA011.xlsx XLSX spreadsheet
Q. IRS Form W-14_W9125PB26RA011.pdf PDF
I. TE_03_Dry_Chemical_OMA_W912PB26RA011.xlsx XLSX spreadsheet
B. PWS_FINAL (28Apr26)_W912PB26RA011.pdf PDF
O. TE_09_Wall_Hydrant_OMA_W912PB26RA011.xlsx XLSX spreadsheet
R. IRS Form W-14 - Sample_W912PB26RA011.pdf PDF
E. Attachment 02 - Authorized Personnel Solicitation_W912PB26RA011.pdf PDF
D. Attachment 01 - CLS 411 (21Apr26) FINAL_W912PB26RA011.pdf PDF
M. TE_07_Sprinkler Systems_AFH & OMA_W912PB26RA011.xlsx XLSX spreadsheet
J. TE_04_Fire_Water_Restraint_OMA_W912PB26RA011.xlsx XLSX spreadsheet
F. Attachment 03_Specification_Maintenance_Tasks_Intervals_W912PB26RA011.xlsx XLSX spreadsheet
H. TE_02_Guardian_OMA and AFH_W9125PB26RA011.xlsx XLSX spreadsheet
C. ELIN Sheet_FINAL_W912PB26RA011.xlsx XLSX spreadsheet
P. TE_10_WILO_OMA_W912PB26RA011.xlsx XLSX spreadsheet
N. TE_08_Sprinkler_Dehoust_AFH_W912PB26RA011.xlsx XLSX spreadsheet
G. TE_01_Ansul_OMA_W912PB26RA011.xlsx XLSX spreadsheet
A. Solicitation - W912PB26RA011.pdf PDF
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

05.1 Vilseck OMA

TE 05.01_Gas Systems_Rose Barracks Vilseck – OMA
Inventory #System
DiscriptionMilitary
CommunityLocation
DetailBuild.#Building
Detail / RoomCons.
Equ.#ManufacturerTypeSerial #
Manufacturer #Make
Year# SystemsLösc hmittel / Extinguish. AgentInhalt US PfundInhalt in kgTreibgas in g
Blowing AgentSprühdüsen
Spray noozleHandauslösung
Manual releaseSignalhupe
Alarm hornInhalt Liter
Content litreSchmelzlot 74 °CSchmelzlot 100 °CSchmelzlot 138 °CSchmelzlot 260 °C12 Volt - Akku - BjAkkutauschSprinkler wetSprinkler trockenNAV "with delay device"TAV with quick openerTrennstation / KombitrennerRohrtrennerRückschlagklappe ≥ DN80≤DN200 / >DN80Steinfänger/FilterAlarmglockeAuslösetemperaturNenninhalt VorratsbehälterNenninhalt VorlagebehälterSprinklerpumpeDruckhaltepumpeKompressorStrömungsmelder StandardStrömungsmeler Zone CheckÜberwachungsanlageLöschmittelflasche
BaujahrLöschmittelflasche
Nr.Löschmittel
ausgetauschtLöschmittel
nächster TauschLöschmittelbehäl-
ter ausgetauschtLöschmittelbehäl-

ter nächster Tausch

105
B 00116 GAS 001Gas SystemRose Barracks1161MinimaxMX 123014 x 71,320

05.2 Grafenwöhr OMA

TE 05.02_Gas Systems_Tower Barracks Grafenwoehr – OMA
Inventory #System
DiscriptionMilitary
CommunityLocation
DetailBuild.#Building
Detail / RoomCons.
Equ.#ManufacturerTypeSerial #
Manufacturer #Make

Year # Systems Lösc hmittel / Extinguish. Agent Löschmittelinhalt in Liter

Extinguishing Agent in LtrInhalt in kgTreibgas in g
Blowing AgentSprühdüsen
Spray noozleHandauslösung
Manual releaseSignalhupe
Alarm hornInhalt Liter
Content litreSchmelzlot 74 °CSchmelzlot 100 °CSchmelzlot 138 °CSchmelzlot 183°CSchmelzlot 260 °C

Löschmittel ausgetauscht

Extinguishing Agent replacednächster Tausch
next changeFlaschen-Nr.Löschmittelbehaelter,

Druckminder, Druckschlauch gewechselt / Agent Container, Pressure

Löschmittelbehaelter- , Druckminder-, Druckschlauch

nächster Wechsel / AgentWärmemelder / Heat Sensor12 Volt - Akku - BjAkkutauschSprinkler wetSprinkler trockenNAV "with delay device"TAV with quick openerLänge der Rohrleitungen mAuslösetemperatur °CTrennstation / KombitrennerRohrtrennerRückschlagklappe ≥ DN80≤DN200 / >DN80Steinfänger/FilterAlarmglockeStrömungsmelder StandardStrömungsmelder Zone CheckÜberwachungsanlageSchaumbehälterNenninhalt DruckluftwasserbehälterNenninhalt VorratsbehälterSprinklerpumpeFörderstrom SprinklerpumpeDruckhaltepumpeFörderstrom DruckhaltepumpeKompressorStrömungswächterDruckschalter Störung StadtwasserDruckschalter Störung SprinklerDruckschalter alarmLöschmittelflasche
BaujahrLöschmittelflasche
Nr.Löschmittel
ausgetauschtLöschmittel
nächster TauschLöschmittelbehäl-
ter ausgetauschtLöschmittelbehäl-

ter nächster Tausch

m³m³m³KWm³/hKWl/minLiterStückbarbarbar
A 00308 GAS 001Gas SystemsGrafenwöhrTower Barracks3081MinimaxGas (MX 200)14x 71.3kg2018Rauchm.2x12V 18Ah Bj 162020
A 00805 GAS 001Gas SystemsGrafenwöhrTower Barracks8051TycoStickst. C N2118 x80 Liter 1x 27 Liter1062x12V 18Ah Bj172021-DN 80-68FMZ 4100-------5041.73.53.0
A 00825 GAS 001Gas SystemsGrafenwöhrTower Barracks8251TycoStickst. C N2114 x140 Liter 1x 27 Liter1062x12V 18Ah Bj172021120DN 80DN 8068FMZ 4100-------4021.54.03.5
A 00855 GAS 001Gas SystemsGrafenwöhrTower Barracks8551TycoStickst. C N2114 x140 Liter 1x 27 Liter1062x12V 18Ah Bj172021-DN 80-68FMZ 4100-------4062.53.53.0
A 00905 GAS 001Gas SystemsGrafenwöhrTower Barracks9051TycoStickst. C N213 x 140 Liter 1 x 27 Liter332x12V 18Ah Bj172021-DN 80-68FMZ 4100-------5062.53.53.0
A 00915 GAS 001Gas SystemsGrafenwöhrTower Barracks9151TycoStickst. C N2114 x 140 Liter 1 x 27 Liter1062x12V 18Ah Bj172021-DN 80-68FMZ 4100-------4062.23.53.0
A 00935 GAS 001Gas SystemsGrafenwöhrTower Barracks9351TycoStickst. C N2118 x80 Liter 1x 27 Liter1062x12V 18Ah Bj 162020DN 10068FMZ 5000--12.5331351.141-6N.V.-7.5
A 0308A GAS 001Gas SystemsGrafenwöhrTower Barracks308A1Kidde DeugraGas (MX 200)18 x 120,4 Kg
1 x 115 Kg1840Rauchm.2x12V 24Ah Bj 19202321DN 100DN 8068FMZ 4100-------9052.52.50.55

8.5 HTA OMA

TE 05.03_Gas Systems_Hohenfels – OMA
Inventory #System
DiscriptionMilitary
CommunityLocation
DetailBuild.#Building
Detail / RoomCons.
Equ.#ManufacturerTypeSerial #
Manufacturer #Make
Year# SystemsLösc hmittel / Extinguish. AgentInhalt US PfundInhalt in kgTreibgas in g
Blowing AgentSprühdüsen
Spray noozleHandauslösung
Manual releaseSignalhupe
Alarm hornInhalt Liter
Content litreSchmelzlot 74 °CSchmelzlot 100 °CSchmelzlot 138 °CSchmelzlot 260 °C12 Volt - Akku - BjAkkutauschSprinkler wetSprinkler trockenNAV "with delay device"TAV with quick openerTrennstation / KombitrennerRohrtrennerRückschlagklappe ≥ DN80≤DN200 / >DN80Steinfänger/FilterAlarmglockeAuslösetemperaturNenninhalt VorratsbehälterNenninhalt VorlagebehälterSprinklerpumpeDruckhaltepumpeKompressorStrömungsmelder StandardStrömungsmeler Zone CheckÜberwachungsanlageLöschmittelflasche
BaujahrLöschmittelflasche
Nr.Löschmittel
ausgetauschtLöschmittel
nächster TauschLöschmittelbehäl-
ter ausgetauschtLöschmittelbehäl-

ter nächster Tausch

tbdGas System541