K. TE_05_Gas Systems_OMA_W912PB26RA011.xlsx
XLSX spreadsheet 25 KB Posted
- Attached to
- Inspection, Maintenance and Repair Work on Fire Extinguisher Systems at USAG Bavaria, Germany
- Solicitation number
- W912PB26RA011
About this file
This is an inventory and equipment specifications document for gas-based fire suppression systems located at multiple U.S. Army installations in Bavaria, Germany, specifically supporting the solicitation W912PB26RA011 for maintenance, inspection, and repair services.
The document details gas fire extinguisher and suppression system inventories across three military installations: Rose Barracks in Vilseck, Tower Barracks in Grafenwoehr, and Hohenfels. Systems documented include Minimax and Tyco nitrogen-based units with specifications such as agent capacity (ranging from 3 to 18 cylinders of 80-140 liters each), blowing agent quantities, spray nozzles, manual release mechanisms, alarm horns, and detection components. Equipment is tracked with manufacturer information, serial numbers, build years (primarily 2020-2023), battery specifications (predominantly 12V 18Ah or 24Ah units with manufacture years noted), and maintenance history including extinguishing agent replacement dates and scheduled future maintenance intervals. Additional system components documented include pressure reducers, discharge hoses, check valves, flow switches, sprinkler systems (both wet and dry types), foam and pressurized water storage containers with capacity ratings, pumps with flow rate specifications, compressors, and alarm bells. The inventory identifies fire suppression infrastructure with pipe diameter specifications (DN80-DN200), temperature thresholds, and pressure switch ratings. This baseline inventory data supports the upcoming IDIQ contract for inspections, maintenance, and repair services with a Period of Performance beginning August 1, 2026.
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
05.1 Vilseck OMA
| TE 05.01_Gas Systems_Rose Barracks Vilseck – OMA | |||
| Inventory # | System | ||
| Discription | Military | ||
| Community | Location | ||
| Detail | Build.# | Building | |
| Detail / Room | Cons. | ||
| Equ.# | Manufacturer | Type | Serial # |
| Manufacturer # | Make |
| Year | # Systems | Lösc hmittel / Extinguish. Agent | Inhalt US Pfund | Inhalt in kg | Treibgas in g | ||||||||||||||||||||
| Blowing Agent | Sprühdüsen | ||||||||||||||||||||||||
| Spray noozle | Handauslösung | ||||||||||||||||||||||||
| Manual release | Signalhupe | ||||||||||||||||||||||||
| Alarm horn | Inhalt Liter | ||||||||||||||||||||||||
| Content litre | Schmelzlot 74 °C | Schmelzlot 100 °C | Schmelzlot 138 °C | Schmelzlot 260 °C | 12 Volt - Akku - Bj | Akkutausch | Sprinkler wet | Sprinkler trocken | NAV "with delay device" | TAV with quick opener | Trennstation / Kombitrenner | Rohrtrenner | Rückschlagklappe ≥ DN80≤DN200 / >DN80 | Steinfänger/Filter | Alarmglocke | Auslösetemperatur | Nenninhalt Vorratsbehälter | Nenninhalt Vorlagebehälter | Sprinklerpumpe | Druckhaltepumpe | Kompressor | Strömungsmelder Standard | Strömungsmeler Zone Check | Überwachungsanlage | Löschmittelflasche |
| Baujahr | Löschmittelflasche | ||||||||||||||||||||||||
| Nr. | Löschmittel | ||||||||||||||||||||||||
| ausgetauscht | Löschmittel | ||||||||||||||||||||||||
| nächster Tausch | Löschmittelbehäl- | ||||||||||||||||||||||||
| ter ausgetauscht | Löschmittelbehäl- |
ter nächster Tausch
| 105 | |||||||||
| B 00116 GAS 001 | Gas System | Rose Barracks | 116 | 1 | Minimax | MX 1230 | 1 | 4 x 71,3 | 20 |
05.2 Grafenwöhr OMA
| TE 05.02_Gas Systems_Tower Barracks Grafenwoehr – OMA | |||
| Inventory # | System | ||
| Discription | Military | ||
| Community | Location | ||
| Detail | Build.# | Building | |
| Detail / Room | Cons. | ||
| Equ.# | Manufacturer | Type | Serial # |
| Manufacturer # | Make |
Year # Systems Lösc hmittel / Extinguish. Agent Löschmittelinhalt in Liter
| Extinguishing Agent in Ltr | Inhalt in kg | Treibgas in g | |||
| Blowing Agent | Sprühdüsen | ||||
| Spray noozle | Handauslösung | ||||
| Manual release | Signalhupe | ||||
| Alarm horn | Inhalt Liter | ||||
| Content litre | Schmelzlot 74 °C | Schmelzlot 100 °C | Schmelzlot 138 °C | Schmelzlot 183°C | Schmelzlot 260 °C |
Löschmittel ausgetauscht
| Extinguishing Agent replaced | nächster Tausch | |
| next change | Flaschen-Nr. | Löschmittelbehaelter, |
Druckminder, Druckschlauch gewechselt / Agent Container, Pressure
Löschmittelbehaelter- , Druckminder-, Druckschlauch
| nächster Wechsel / Agent | Wärmemelder / Heat Sensor | 12 Volt - Akku - Bj | Akkutausch | Sprinkler wet | Sprinkler trocken | NAV "with delay device" | TAV with quick opener | Länge der Rohrleitungen m | Auslösetemperatur °C | Trennstation / Kombitrenner | Rohrtrenner | Rückschlagklappe ≥ DN80≤DN200 / >DN80 | Steinfänger/Filter | Alarmglocke | Strömungsmelder Standard | Strömungsmelder Zone Check | Überwachungsanlage | Schaumbehälter | Nenninhalt Druckluftwasserbehälter | Nenninhalt Vorratsbehälter | Sprinklerpumpe | Förderstrom Sprinklerpumpe | Druckhaltepumpe | Förderstrom Druckhaltepumpe | Kompressor | Strömungswächter | Druckschalter Störung Stadtwasser | Druckschalter Störung Sprinkler | Druckschalter alarm | Löschmittelflasche |
| Baujahr | Löschmittelflasche | |||||||||||||||||||||||||||||
| Nr. | Löschmittel | |||||||||||||||||||||||||||||
| ausgetauscht | Löschmittel | |||||||||||||||||||||||||||||
| nächster Tausch | Löschmittelbehäl- | |||||||||||||||||||||||||||||
| ter ausgetauscht | Löschmittelbehäl- |
ter nächster Tausch
| m³ | m³ | m³ | KW | m³/h | KW | l/min | Liter | Stück | bar | bar | bar | ||||||||||||||||||||||||||||||||||
| A 00308 GAS 001 | Gas Systems | Grafenwöhr | Tower Barracks | 308 | 1 | Minimax | Gas (MX 200) | 1 | 4x 71.3kg | 20 | 18Rauchm. | 2x12V 18Ah Bj 16 | 2020 | ||||||||||||||||||||||||||||||||
| A 00805 GAS 001 | Gas Systems | Grafenwöhr | Tower Barracks | 805 | 1 | Tyco | Stickst. C N2 | 1 | 18 x80 Liter 1x 27 Liter | 10 | 6 | 2x12V 18Ah Bj17 | 2021 | - | DN 80 | - | 68 | FMZ 4100 | - | - | - | - | - | - | - | 50 | 4 | 1.7 | 3.5 | 3.0 | |||||||||||||||
| A 00825 GAS 001 | Gas Systems | Grafenwöhr | Tower Barracks | 825 | 1 | Tyco | Stickst. C N2 | 1 | 14 x140 Liter 1x 27 Liter | 10 | 6 | 2x12V 18Ah Bj17 | 2021 | 120 | DN 80 | DN 80 | 68 | FMZ 4100 | - | - | - | - | - | - | - | 40 | 2 | 1.5 | 4.0 | 3.5 | |||||||||||||||
| A 00855 GAS 001 | Gas Systems | Grafenwöhr | Tower Barracks | 855 | 1 | Tyco | Stickst. C N2 | 1 | 14 x140 Liter 1x 27 Liter | 10 | 6 | 2x12V 18Ah Bj17 | 2021 | - | DN 80 | - | 68 | FMZ 4100 | - | - | - | - | - | - | - | 40 | 6 | 2.5 | 3.5 | 3.0 | |||||||||||||||
| A 00905 GAS 001 | Gas Systems | Grafenwöhr | Tower Barracks | 905 | 1 | Tyco | Stickst. C N2 | 1 | 3 x 140 Liter 1 x 27 Liter | 3 | 3 | 2x12V 18Ah Bj17 | 2021 | - | DN 80 | - | 68 | FMZ 4100 | - | - | - | - | - | - | - | 50 | 6 | 2.5 | 3.5 | 3.0 | |||||||||||||||
| A 00915 GAS 001 | Gas Systems | Grafenwöhr | Tower Barracks | 915 | 1 | Tyco | Stickst. C N2 | 1 | 14 x 140 Liter 1 x 27 Liter | 10 | 6 | 2x12V 18Ah Bj17 | 2021 | - | DN 80 | - | 68 | FMZ 4100 | - | - | - | - | - | - | - | 40 | 6 | 2.2 | 3.5 | 3.0 | |||||||||||||||
| A 00935 GAS 001 | Gas Systems | Grafenwöhr | Tower Barracks | 935 | 1 | Tyco | Stickst. C N2 | 1 | 18 x80 Liter 1x 27 Liter | 10 | 6 | 2x12V 18Ah Bj 16 | 2020 | DN 100 | 68 | FMZ 5000 | - | - | 12.5 | 33 | 135 | 1.1 | 41 | - | 6 | N.V. | - | 7.5 | |||||||||||||||||
| A 0308A GAS 001 | Gas Systems | Grafenwöhr | Tower Barracks | 308A | 1 | Kidde Deugra | Gas (MX 200) | 1 | 8 x 120,4 Kg | ||||||||||||||||||||||||||||||||||||
| 1 x 115 Kg | 18 | 40Rauchm. | 2x12V 24Ah Bj 19 | 2023 | 21 | DN 100 | DN 80 | 68 | FMZ 4100 | - | - | - | - | - | - | - | 90 | 5 | 2.5 | 2.5 | 0.55 |
8.5 HTA OMA
| TE 05.03_Gas Systems_Hohenfels – OMA | |||
| Inventory # | System | ||
| Discription | Military | ||
| Community | Location | ||
| Detail | Build.# | Building | |
| Detail / Room | Cons. | ||
| Equ.# | Manufacturer | Type | Serial # |
| Manufacturer # | Make |
| Year | # Systems | Lösc hmittel / Extinguish. Agent | Inhalt US Pfund | Inhalt in kg | Treibgas in g | ||||||||||||||||||||
| Blowing Agent | Sprühdüsen | ||||||||||||||||||||||||
| Spray noozle | Handauslösung | ||||||||||||||||||||||||
| Manual release | Signalhupe | ||||||||||||||||||||||||
| Alarm horn | Inhalt Liter | ||||||||||||||||||||||||
| Content litre | Schmelzlot 74 °C | Schmelzlot 100 °C | Schmelzlot 138 °C | Schmelzlot 260 °C | 12 Volt - Akku - Bj | Akkutausch | Sprinkler wet | Sprinkler trocken | NAV "with delay device" | TAV with quick opener | Trennstation / Kombitrenner | Rohrtrenner | Rückschlagklappe ≥ DN80≤DN200 / >DN80 | Steinfänger/Filter | Alarmglocke | Auslösetemperatur | Nenninhalt Vorratsbehälter | Nenninhalt Vorlagebehälter | Sprinklerpumpe | Druckhaltepumpe | Kompressor | Strömungsmelder Standard | Strömungsmeler Zone Check | Überwachungsanlage | Löschmittelflasche |
| Baujahr | Löschmittelflasche | ||||||||||||||||||||||||
| Nr. | Löschmittel | ||||||||||||||||||||||||
| ausgetauscht | Löschmittel | ||||||||||||||||||||||||
| nächster Tausch | Löschmittelbehäl- | ||||||||||||||||||||||||
| ter ausgetauscht | Löschmittelbehäl- |
ter nächster Tausch
| tbd | Gas System | 54 | 1 |
| tbd | Gas System | 1123 | 1 |
File details come from the government source that posted it. Updated .