McCook Reservoir Stage II Grout Curtain W912P6-09-R-0006
The activities of other contractors and activities at the site have impacted the berm and slope conditions, and the conditions depicted in the drawings with respect to soil slopes may or may not be representative of those encountered upon the start of work under this contract. The Contractor shall survey and assess the areas of his Work Platform prior to submittal of his Work Plan for construction of this feature of the work, and verify the location of the grout curtain with respect to the overburden cutoff wall.
The grades will be esentially restored by others along the east side of the project area prior to execution of Option 1, to the elevations shown in the drawings.
1.3 LOGISTICAL CONSTRAINTS
Access to the area is limited by the location of the ongoing quarrying operations, and the operations of other contractors at the LASMA location.
An access ramp to the berm along the canal side of the site is present from Lagoon 21. It may be possible to obtain very limited access to the berm from the northeast end of Lagoon 1; however, there will be no other access permitted, and the Contractor's access will be restricted to the confines of the work areas defined in the Drawings. Access through the Option 1 area to the Base Bid area will be possible prior to the execution of the Options; however access may be limited by the operations of other contractors during that time, and coordination with the COR will be required throughout the contract duration for this accessThe Contractor shall maintain the ramp in Lagoon 21 and its accessibility for the duration of the Contract.
In addition to congested access, the operations of the other contractors operating in and around LASMA, the Contractor shall consider the constraints of the sludge train tracks and operation of the MWRDGC rail operations immediately adjacent and in close proxmity to the grout curtain on the canalside of the work area in the planning and execution of the work, and conform with safe clearance distances for work in the vicinity of active train tracks mandated by OSHA and the provisions of EM 385 1-1, 2008. The Contractors operations shall not interfere with the operations of the MWRDGC railroad and interruptions or delays of the railroad will not be permitted.
The quarry operator, Vulcan Materials, will also be conducting excavation by drilling and blasting on a regular daily production schedule and there may be interruptions to the work, on a daily basis when blasting occurs.
Blasting occurs at the discretion of the quarry operator. In general, blasting occurs in the afternoon with shutdowns lasting no longer than 30 minutes. All personnel in the blast zone must vacate the area. The blast zone is identified as Lagoons 1 through 10 inclusive. Incurred stand-by due to blasting totaling a whole day will be granted a contract extension. The canalside portion of the Stage 2 Grout Curtain will be constructed on a narrow berm shared with teh MWRDGC's sludge transportation rail line, elevated between the Chicago Sanitary and Ship Canal and the working McCook Reservoir Quarry. Portions of the canal were constructed by excavation that may have included blasting the underlying bedrock. Operations under the Contract shall not impede the work of other contractors at the LASMA site. Based on these conditions, the Contractor's technical approach should consider the potential for blast fracturing influences on grout migration.
DOCUMENT 00 31 19.01 03 - Page 3
AMD-0002
McCook Reservoir Stage II Grout Curtain W912P6-09-R-0006
1.4 EXISTING REPORTS
Existing reports that provide background to the project work area are available to be reviewed in the Chicago District Office and are listed in Section 00 31 32.13 03. Existing reports completed to evaluate soil contamination and/or hazardous materials in the project work area are also available. No potential Hazardous, Toxic, and Radioactive Waste (HTRW) are listed for the project work area. These reports may be reviewed by contacting the U.S. Army Corps of Engineers, Chicago District at 111 North Canal Street, Chicago, Illinois 60606-7206 (Attn: Joe Kissane, 312-846-5453).
PART 2 PRODUCTS (NOT APPLICABLE)
PART 3 EXECUTION (NOT APPLICABLE)
-- End of Section --
DOCUMENT 00 31 19.01 03 - Page 4
SD-02 Shop Drawing
IP Web Camera-1 IP Web Camera-2 P-1 Radio Antenna Pole
Pole Height: 32ft Pole Height: 32ft Pole Height: 32ft
Camera Mounting Height:
28ft
Camera Mounting
Height: 28ft
Camera Mounting
Height: N/A
Antenna Mounting Height:
30ft
Antenna Mounting
Height: 30ft
Antenna Mounting
Height: 30ft
Access Point Mounting
Height: 12ft
Access Point Mounting
Height: 12ft
Access Point Mounting
*ACOE Trailer
McCook Reservoir Stage II Grout Curtain
28 23 29.00 03_ Existing Webcam System
SD-03 Product Data - Manufacturers Data Package
Section 1.3.6
B. System Startup and Shutdown Procedures.
1. Starting and shutting down of the computer.
a. To start the computer you will need to turn it on as well as the monitor connected to it. The computer will boot up to a log-on screen where you will be prompted to enter in your user name and password.
b. To shut down the computer you will need to close all programs that you are running on the computer first. Then press the start button with the mouse and select Shut down from the Start menu.
A new menu should pop up where you will want to select shut down from that menu and press OK. The computer will then shutdown and also turn off the monitor.
C. Manuals for the IP Camera equipment
1. See the included Adobe PDF files:
a. Web Cam Spec Sheet.pdf
b. Instructions for the PFD7CN-9 Webcam.pdf D. Manuals for the Wireless Equipment
1. See the included Adobe PDF files:
a. Cisco 1240 AG Data Sheet.pdf
b. Cisco 1240 Hardware Installation.pdf
c. Cisco 1240 Quick Start guide.pdf
d. Cisco 1240 Configuration Guide.pdf
Additional Equipment and documentation for the equipment
Workstation Server:
See Adobe PDF file: Dimension 3100 Product Details.pdf Surge Protector/Backup :
See Adobe PDF file: UPS Surge Protector.pdf Antennas:
See Adobe PDF file: Yagi Antenna.pdf and Sector Panel Antenna.pdf Equipment Enclosure:
See Adobe PDF file: Nema Enclosure.pdf Fire Wall Equipment:
See Adobe PDF file: Cisco Pix Firewall.pdf
The type of data encryption that will be used is 128-bit WEP encryption between the wireless access points. And the Virus Protection will be by Symantec.
McCook Reservoir Stage II Grout Curtain
28 23 29.00 03_ Existing Webcam System
PRM30G
Aluminum parapet mount bracket with 20” extension, includes 1½” NPT
WM20G
Aluminum gooseneck wall bracket includes
1½” NPT
WM30G
Aluminum parapet mount bracket, includes 1½” NPT
PS2496N
NEMA 4x rated outdoor plastic enclosure, 115Vac input, 24Vac output:
1 Camera output - 1.1A 1 Heater output - 4A (96vA)
CWKFD2
24Vac Cold Weather Kit for an additional heater and blower For Outdoor FusionDomes in extremely cold weather
PB24
Rugged cast aluminum power box with 84vA and 24vA power supply
ACA2
Aluminum corner mount bracket with female inserts
IP Network SView™
PRODUCT DESCRIPTION
The IP S-View™ is Videolarm’s own network pan/tilt/zoom camera system available in five distinguishing enclosures. These camera systems have astonishing capabilities.
Unlike any other IP cameras Videolarm’s is designed for the outdoors with metal gearing and a durable pan/tilt. You can choose from MPEG-4 & MJPEG video compression format with 30/25 FPS video refresh rate at Full D1 resolution. The IP S-View2™ features an auto focus, hi-res, true day/night camera which has a .02 lux minimum illumination when the IR filter is removed. The camera offers 230x zoom (23x optical and 10x digital) with 360° continuous rotation at 180° or 360°/sec.
This unit is capable of 18 presets and auto tour, up to two minutes of recordable pattern, and a host of other features. T he S-View2™ is perfect for perimeter security, parking lots, airports...anyplace day/night capabilities are essential.
PRODUCT FEATURES
• MPEG-4 & MJPEG video compression format
• Adjustable video compression
• 30/25 FPS@ Full D1
(720x480 / 720x576) resolution
• Auto Focus, High-Res Integrated
Day/Night IR sensitive Camera/lens Package
• 230x zoom (23x optical and 10x digital)
• 18 presets
• Automatic flip-over
• 24 vac input
• 360° continuous rotation
• 16 user selectable privacy zones
• Digital zoom on/off
• ±0.1° Preset Accuracy
• 120°/sec Pan and Tilt Preset Speed
• 16 user selectable privacy zones
ACCESSORIES:
MODELS:
Wireless Option
FDW7CN-9: Outdoor dome with ptz IP camera system, wall mount.
23x zoom Day & night camera. MPEG-4 & MJPEG video compression format, Full D1. Clear dome, w/24Vac input, heater/blower
RHW7CN-9: Outdoor vandal resistant dome with ptz IP camera system, wall mount. 23x zoom Day & night camera. MPEG-4 & MJPEG video compression format, Full D1. Clear dome, w/24Vac input, heater/blower
PFD7CN-9: Pressurized Outdoor dome with ptz IP camera system, pendant mount. 23x zoom Day & night camera. MPEG-4 & MJPEG video compression format, Full D1. Clear dome, w/24Vac input, heater/blower
IFDP7CN-9: Indoor dome with ptz IP camera system, pendant mount.
23x zoom Day & night camera. MPEG-4 & MJPEG video compression format, Full D1. Clear dome
MR5TN-9: Indoor recessed dome with ptz IP camera system, pendant mount. 23x zoom Day & night camera. MPEG-4 & MJPEG video compression format, Full D1. Tinted dome
SM7CN-9: Outdoor vandal resistant surface mount ptz IP camera system -that can be mounted facing down or facing towards the sky. 23x zoom Day & night camera. MPEG-4 & MJPEG video compression format, Full D1. Clear dome, w/24Vac input, heater/blower
FDWCN-9
pendant mount avaialble
RHWCN-9
pendant mount avaialble
PFDCN-9
pressurized model
MR5TN-9
indoor model
SM7CN-9
surface mount
APM3
Aluminum pole mount bracket with female inserts
CA15
Ceiling mount adapter, with Junction Box, 1½” NPT
IP Network SView™
IP SView™
McCook Reservoir Stage II Grout Curtain
28 23 29.00 03_ Existing Webcam System
Video Specifications Image Compression: MPEG-4 Simple Profile (SP);
JPEG; MJPEG
Video Adjustment: Brightness, Contrast, Hue, Saturation, Frame rate, Bit rate (Constant Bit Rate (CBR), Variable Bit Rate (VBR) w/ quality levels), Frame Sequence (I-Frame, I- Frame/P-Frame)
Resolutions: Full D1 (4SIF): NTSC=720x480 VGA: 640x480 SIF: NTSC = 352x240 QVGA: 320x240 QSIF: NTSC = 176x 112 QQVGA: 160x112
Lens: 23x optical, (f=3.6mm - 82.8mm), 10x digital zoom
Minimum illumination: 3 kux @ 1/60s, .2 lux @ 1/4s, .02 lux (1/4s, IR cut filter removed)
Network Specifications
Network Interface: 10/100 Base-T Ethernet
Protocols: TCP(UDP)/IP, ICMP, HTTP, TFTP, FTP, Telnet, SMTP, DHCP, NTP, DNS, DDNS, RTSP, RTP/TCP(UDP)
Mechanical Specifications PAN/TILT
Pan Movement: 360° Continuous pan rotation
Vertical Tilt Unobstructed: 2° to -90°
Manual Pan/Tilt Speeds: 0.5°-80°/sec manual operation
Preset Pan/Tilt Speeds: 120°/sec
Positioning: +/-.05 degree
Construction: Aluminum
Motors: Stepper motors
Gearing: Belt-driven, 1/4” wide
Bearings: Precision ball bearings, permanently lubricated bushings
IP Network SView™
ARCHITECTURAL/ENGINEERING SPECIFICATIONS
Camera System (for all models) The camera system shall output MPEG-4 or MJEG image compression.
The user can adjust brightness, contrast, Hue, Saturation, Frame rate, Bit rate, Interlaced/Progressive Scanning. The resolution can be set at full D1 (4SIF): NTSC = 720x480, VGA (SIF), QVGA, QSIF or QQVGA.
The camera shall be a true day/night camera with a 1/4” interline transfer CCD and a resolution of 470 horizontal TV lines. The minimum illumination shall be 3 lux @ 1/60s, .2 lux @ 1/4s for color and .02 lux (1/4s, IR cut filter removed) for black and white. The camera shall be sensitive to infra-red light. The lens shall be 23x optical and 10x digital.
Angle of view shall be 54˚ at the high end and 2.5˚ at the tele end.
The pan/tilt/zoom shall constructed of aluminum and shall contain belt driven stepper motors and precision ball bearings with permanently lubricated bushings. The pan/tilt/zoom shall be capable of 360° continuous rotation at 0.1˚ to 80˚/second, and shall be capable of 180° flip over. Tilt shall be 0˚ to 90˚ at 0.5˚ to 80˚/second. Software programmable pan and tilt limits shall be included. Sixty-four presets shall be available, with preset speeds of 120˚/second for both pan and tilt with an accuracy of +/- .05˚. Auto tour shall also be included, and the unit shall be capable of recording up to two minutes of a set pattern for playback as a preset. Sixteen user selectable privacy zones shall be available. User selectable items shall be available via an on-screen menu.
Metal PTZ
Supported by the following NVR companies:
ONSSI
LuxRiot
Webcam Corp.
D3DATA
Ortega
Visual Sentry
JDS
Planet CCTV
Griffid
McCook Reservoir Stage II Grout Curtain
28 23 29.00 03_ Existing Webcam System
Mechanical Specifications Size:
FD7 wall mount FDW7 FD7 pendant mount FDP7 RH7 pendant mount RHW7 RH7 pendant mount RHP7
PFD7
13.28x10.03x14.69” (337x255x373mm) 13.38x11.42”x11.42” (340 x 290 x 290mm) 13.38x11.42”x11.42” (340 x 290 x 290mm) 13.36”x 9.73”x14.69” (340 x 247 x 373mm) 13.38”x11.42”x11.42” (340x 290 x 290mm)
Weight: FD7
RH7
PFD7
10 lbs (4.6kg) 12 lbs (5.5 kg) 11 lbs (5.0 kg)
Construction Body: FD7
RH7
PFD7
High-impact engineered plastic, UV protected, with a UL flame rating of 94V0
Cast Aluminum
High-impact engineered plastic, UV protected, with a UL flame rating of 94V0
Dome: all OptiClear™ polycarbonate
Mount/ Bracket: all Cast aluminum
Electrical Specifications
Power requirements: FD7
RH7
PFD7
24vac, 47watts (va) 24vac, 76watts (va) 24vac, 76watts (va)
Environmental Specifications Operating Temperature:
FD7
RH7
PFD7
--40º F to 120º F (--40° C to + 50° C)
--20º F to 120º F (--40° C to + 50° C)
-50º F to 120º F (-45° C to + 50° C)
IP Network SView™ FDW7CN-9, RHW7CN-9, PFD7CN-9
ARCHITECTURAL/ENGINEERING SPECIFICATIONS
FD7 (Standard Indoor and Outdoor Housing) The FusionDome™ housings shall be available as an indoor, without electronics, or as outdoor, with heater and blower. It shall be available with a wall or pendant mount. The housing shall be manufactured from a high-impact engineered plastic, UV protected, with a UL flame rating of 94V0. The dome shall be injection molded OptiClearTM polycarbonate; clearest in the industry. It shall be held in place with (3) fasteners, and sealing O-ring shall be included. A safety cable shall be provided to hold the dome while servicing. Access to the enclosure shall be from below. Outdoor models shall have a blower and thermostatically controlled heater, allowing a temperature range of -20˚ F to +140˚ F. These units shall have a 24 vac input.
RH7 (Vandal Resistant Indoor/Outdoor housing) The RH7 vandal resistant dome shall be a wall or Pendant mounted outdoor dome housing. The housing top shall be manufactured from durable cast aluminum. The dome shall be injection molded polycarbonate and polished to be OptiClearTM, guarantee to be the clearest in the industry. It shall be held in place with (3) fasteners, and sealing O-ring shall be included. A safety cable shall be provided to hold the dome while servicing. Access to the enclosure shall be from below. A heater/blower combination shall be available, effective in temperature ranges from -20˚F to +140˚F. The heater shall be thermostatically controlled. Power input shall be 24 vac.
PFD7 (Pressurized housing) The PFD7 housing shall be an outdoor housing comes standard with a pendant mount. A WM20G can be added for wall mount applications A Schraeder valve is located on top of the machined aluminum plate to allow 5psi of nitrogen gas to enter the dome. A second valve, a pressure relief valve, provides an escape for pressure exceeding 5 psi. Two (2) o-ring seals shall be included, 0.136” x 9.25” (inner diameter) and 0.136” x 4.5” (inner diameter).
A 10-pin hermetically sealed connector, located at the top of the pressurized housing shall provide power, video and control functions. The housing shall be constructed of 0.125” durable engineered plastic, UV with a UL flame rating of 94V0. The dome shall be injection molded OptiClearTM polycarbonate;
clearest in the industry. The dome shall be held in place with minimum of (9) fasteners located on the trim ring, and a safety cable shall be provided to hold the dome while servicing. The trim ring is then used to press the dome against a sealing o-ring.
A twist-off feature allows for the final removal of the dome from below. The blower shall draw 1.4 watts continuous power.
The 50 watt heater shall turn on at 40°F and turn off at 60°F.
Enclosures are equipped with blowers and thermostatically controlled heaters, allowing a temperature range of - 50˚ F to +120˚ F. Power input shall be 24 vac.
CERTIFICATIONS AND RATINGS
Pendant mount version IP66, PFD7 is IP67, NEMA 4x, UL, CUL
R 9.53 ( 242.2 )
R 2.37 ( 60.3 )
R 11.67 ( 296.3 )
R 9.25 ( 234.9 )
R 11.74 ( 298.3 )
R 5.00 ( 127 )
R 3.75 ( 95.2 )
2.25 ( 57.2 )
11.42 ( 290 )
13.38 ( 339.8 )
14.68 ( 373 )
R 3.75 ( 95.2 )
7.00 ( 177.8 )
FD7
Wall Mount
FDW7CN-9
RH7
Wall Mount
RHW7CN-9
PFD7
Pendant Mount
PFD7CN-9
FD7, RH7, PFD7
McCook Reservoir Stage II Grout Curtain
28 23 29.00 03_ Existing Webcam System
Mechanical Specifications Size:
SM7
MR5
11.4” x 11.2” x 11.6” (292 x 287 x 297mm) 8.54” x 8.38” x 8.38” (217 x 213 x 213mm)
Weight: SM7
MR5
15 lbs (6.8kg) 10 lbs (4.6 kg)
Construction Body: SM7
MR5
Cast Aluminum
Stamped Metal
Dome: all OptiClear™ polycarbonate
Mount/ Bracket: SM7 Cast aluminum
Electrical Specifications
Power requirements: SM7
MR5
24vac, 76watts (va) 24vac, 24watts (va)
Environmental Specifications Operating Temperature:
SM7
MR5
--20º F to 120º F (--40° C to + 50° C)
32º F to 120º F (0° C to + 50° C)
O .34 ( 8.6 ) O .31
( 7.9 )
R 2.94 ( 74.6 )
5.90 ( 149.9 )
7.21 ( 183.1 )
8.70 (220.9)
R 8.38 ( 212.9 )
R .19 ( 4.8 )
IP Network SView™ SM7CN-9, MR5TN-9
ARCHITECTURAL/ENGINEERING SPECIFICATIONS
SM7 (Surface Mount Indoor/Outdoor housing) The SM7CN-9 vandal resistant housing shall be an outdoor housing available in either wall (using WMSM7) or surface mounted versions.
Blowers and thermostatically controlled heaters shall be standard, allowing a temperature range of -25° F to +120° F. Units will be available with 24 VAC inputs. The housing top shall be manufactured from durable cast aluminum. The dome shall be made of optically clear, injection molded polycarbonate material, and shall be held in place with (3) fasteners, and a sealing O-ring shall be included. A safety cable shall be provided to hold the dome while servicing.
MR5 (Recessed Indoor Ceiling housing) The recessed ceiling mount dome housing shall be a VIDEOLARM model MR5TN-9, MR5CN-9 or equivalent and shall be capable of installation in sheetrock or drop ceilings. The body shall be held in place in the ceiling with two spring clips. The body shall be manufactured from stamped metal and be capable of being installed in its entirety from below the ceiling. The lower acrylic dome will be free-blown using cell-cast clear or tinted acrylic (1 F-stop light reduction for tinted lower dome). A trim ring shall be included, and shall be constructed of ABS plastic.
CERTIFICATIONS AND RATINGS
NEMA 4x, UL, CUL
A
A
11.56 [ 293.8]
10.06 [ 255.6]
10.09 [ 256.3]
11.44 [ 290.5]O
R 3.75 [ 95.2]
7.25 [ 184.1]
7.25 [ 184.1]
5.41 [ 137.5]
6.15 [ 156.2]
SM7
Surface Mount
SM7CN-9
MR5
Recessed
Ceiling Mount
MR5TN-9
SM7, MR5
McCook Reservoir Stage II Grout Curtain
28 23 29.00 03_ Existing Webcam System
TM
81-IN5382R1-
www.videolarm.com
P F D 7 C N - 9 SView Outdoor Pressurized FusionDome
Installation and Operation Instructions for the following models:
PFD7CN-9 IP Network Ready 7” Pressurized Outdoor PTZ Camera System with 23x zoom compression, full D1. Clear dome, with 24Vac input, heater/ blower
PFD7CS-9 (Analog version) IP Network Ready 7” Pressurized Outdoor PTZ Camera System with 23x zoom compression, full D1. Clear dome, with 24Vac input, heater/ blower
B e fo re at te m p t i n g to co n n e c t o r o p e rate t h i s p ro d u c t , p l e a s e re a d t h e s e i n s t r u c t i o n s co m p l e te l y. To b e u s e d w i t h t h e 8 1 - I N 5 4 0 9 I n s t r u c t i o n M a n u a l .
McCook Reservoir Stage II Grout Curtain
28 23 29.00 03_ Existing Webcam System
IMPORTANT SAFEGUARDS SAFETY PRECAUTIONS
UNPACKING
SERVICE
1 Read these instructions.
2 Keep these instructions.
3 Heed all warnings
4 Follow all instructions.
5 Do not use this apparatus near water.
6 Clean only with damp cloth.
7 Do not block any of the ventilation openings. Install in accordance with the manufacturers instructions.
8 Cable Runs- All cable runs must be within permissible distance.
9 Mounting - This unit must be properly and securely mounted to a supporting structure capable of sustaining the weight of the unit.
Accordingly:
a. The installation should be made by a qualified installer.
b. The installation should be in compliance with local codes.
c. Care should be exercised to select suitable hardware to install the unit, taking into account both the composition of the mounting surface and the weight of the unit.
10 Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus ( including amplifiers) that produce heat.
11 Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. When the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
12 Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
13 Only use attachment/ accessories specified by the manufacturer.
14 Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/ apparatus combination to avoid injury from tip-over.
15 Unplug this apparatus during lighting storms or when unused for long periods of time.
16 Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled of objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
Be sure to periodically examine the unit and the supporting structure to make sure that the integrity of the installation is intact. Failure to comply with the foregoing could result in the unit separating from the support structure and falling, with resultant damages or injury to anyone or anything struck by the falling unit.
Unpack carefully. Electronic components can be damaged if improperly handled or dropped. If an item appears to have been damaged in shipment, replace it properly in its carton and notify the shipper.
Be sure to save:
1 The shipping carton and packaging material.
They are the safest material in which to make future shipments of the equipment.
2 These Installation and Operating Instructions.
If technical support or service is needed, contact us at the following number:
The lightning flash with an arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of non-insulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk to persons.
Este símbolo se piensa para alertar al usuario a la presencia del “voltaje peligroso no-aisIado” dentro del recinto de los productos que puede ser un riesgo de choque eléctrico.
Ce symbole est prévu pour alerter I’utilisateur à la presence “de la tension dangereuse” non-isolée dans la clôture de produits qui peut être un risque de choc électrique.
Dieses Symbol soll den Benutzer zum Vorhandensein der nicht-lsolier “Gefährdungsspannung” innerhalb der Produkteinschließung alarmieren die eine Gefahr des elektrischen Schlages sein kann.
Este símbolo é pretendido alertar o usuário à presença “di tensão perigosa non-isolada” dentro do cerco dos produtos que pode ser um risco de choque elétrico.
Questo simbolo è inteso per avvertire I’utente alla presenza “di tensione pericolosa” non-isolata all’interno della recinzione dei prodotti che può essere un rischio di scossa elettrica.
The exclamation point within an equilateral triangle is intended to alert the user to presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Este símbolo del punto del exclamation se piensa para alertar al usuario a la presencia de instrucciones importantes en la literatura que acompaña la aplicación.
Ce symbole de point d’exclamation est prévu pour alerter l’utilisateur à la presence des instructions importantes dans la littérature accompagnant l’appareil.
Dieses Ausruf Punktsymbol soll den Benutzer zum Vorhandensein de wichtigen Anweisungen in der Literatur alarmieren, die das Gerät begleitet.
Este símbolo do ponto do exclamation é pretendido alertar o usuário à presença de instruções importantes na literatura que acompanha o dispositivo.
Questo simbolo del punto del exclamaton è inteso per avvertire l’utente alla presenza delle istruzioni importanti nella letteratura che accompagna l'apparecchio.
TECHNICAL SUPPORT
AVAILABLE 24 HOURS
1 - 800 - 554 -1124
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION
CAUTION: TO REDUCE THE RISK OF
ELECTRIC SHOCK, DO NOT REMOVE
COVER ( OR BACK). NO USER- SERVICE-
ABLE PARTS INSIDE. REFER SEVICING TO
QUALIFIED SERVICE PERSONNEL.
McCook Reservoir Stage II Grout Curtain
28 23 29.00 03_ Existing Webcam System
LIMITED WARRANTY FOR VIDEOLARM INC. PRODUCTS
VIDEOLARM INC. warrants this Product to be free from defects in material or workmanship, as follows:
PRODUCT CATEGORY PARTS LABOR
All Enclosures and Electronics Three (3) Years Three (3) Years Pan/Tilts Three (3) Years **6 months if used in autoscan Three (3) Years **6 months if used in autoscan Poles/PoleEvators Three (3) Years Three (3) Years Warrior/Q-View/I.R. Illuminators/SView Five (5) Years Five (5) Years Controllers Three (3) Years Three (3) Years Power Supplies Three (3) Years Three (3) Years Accessory Brackets Three (3) Years Three (3) Years During the labor warranty period, to repair the Product, Purchaser will either return the defective product, freight prepaid, or deliver it to Videolarm Inc.
Decatur GA. The Product to be repaired is to be returned in either its original carton or a similar package an equal degree of protection with a RMA # (Return Materials Authorization number) displayed on the outer box or packing slip. To obtain a RMA# you must contact our Technical Support Team at 800.554.1124, extension 101. Videolarm will return the repaired Product freight prepaid to Purchaser. Videolarm is not obligated to provide Purchaser with a substitute unit during the warranty period or at any time. After the applicable warranty period, Purchaser must pay all labor and/or parts charges.
The limited warranty stated in these product instructions is subject to all of the following terms and conditions:
1. NOTIFICATION OF CLAIMS: WARRANTY SERVICE: If Purchaser believes that the Product is defective in material or workmanship, then written notice with an explanation of the claim shall be given promptly by Purchaser to Videolarm but all claims for warranty service must be made within the warranty period. If after investigation Videolarm determines that the reported problem was not covered by the warranty, Purchaser shall pay Videolarm for the cost of investigating the problem at its then prevailing per incident billable rate. No repair or replacement of any Product or part thereof shall extend the warranty period as to the entire Product. The warranty on the repaired part only shall be in for a period of ninety (90) days following the repair or replacement of that part or the remaining period of the Product parts warranty, whichever is greater.
2. EXCLUSIVE REMEDY: ACCEPTANCE: Purchaser’s exclusive remedy and Videolarm’s sole obligation is to supply (or pay for) all labor necessary to repair any Product found to be defective within the warranty period and to supply, at no extra charge, new or rebuilt replacements for defective parts.
3. EXCEPTIONS TO LIMITED WARRANTY: Videolarm shall have no liability or obligation to Purchaser with respect to any Product requiring service during the warranty period which is subjected to any of the following: abuse, improper use: negligence, accident, lightning damage or other acts of God (i.e., hurricanes, earthquakes), failure of the end-user to follow the directions outlined in the product instructions, failure of the end-user to follow the maintenance procedures recommended by the International Security Industry Organization, written in product instructions, or recommended in the service manual for the Product. Furthermore, Videolarm shall have no liability where a schedule is for regular replacement or maintenance or cleaning of certain parts (based on usage) and the end-user has failed to follow such schedule; attempted repair by personnel; operation of the Product outside of the published environmental and electrical parameters, or if such Product’s original (trademark, serial number) markings have been defaced, altered, or removed. Videolarm excludes from warranty coverage Products sold
AS IS and/or WITH ALL FAULTS and excludes used Products which have not been sold by Videolarm to the Purchaser. All software and accompanying documentation furnished with, or as part of the Product is furnished “AS IS” (i.e., without any warranty of any kind), except where expressly provided otherwise in any documentation or license agreement furnished with the Product.
4. PROOF OF PURCHASE: The Purchaser’s dated bill of sale must be retained as evidence of the date of purchase and to establish warranty eligibility.
DISCLAIMER OF WARRANTY EXCEPT FOR THE FOREGOING WARRANTIES, VIDEOLARM HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO ANY AND/OR ALL IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND/OR ANY WARRANTY WITH REGARD TO ANY CLAIM OF INFRINGEMENT THAT MAY BE PROVIDED IN SECTION 2-312(3) OF THE UNIFORM COMMERCIAL CODE AND/OR IN ANY OTHER COMPARABLE STATE STATUTE. VIDEOLARM HEREBY DISCLAIMS ANY REPRESENTATIONS OR WARRANTY THAT THE PRODUCT IS COMPATIBLE WITH ANY COMBINATION OF NON-VIDEOLARM PRODUCTS OR NON-VIDEOLARM RECOMMENDED PRODUCTS PURCHASER CHOOSES TO CONNECT TO PRODUCT.
LIMITATION OF LIABILITY THE LIABILITY OF VIDEOLARM, IF ANY, AND PURCHASER’S SOLE AND EXCLUSIVE REMEDY FOR DAMAGES FOR ANY CLAIM OF ANY KIND WHATSOEVER, REGARDLESS OF THE LEGAL THEORY AND WHETHER ARISING IN TORT OR CONTRACT, SHALL NOT BE GREATER THAN THE ACTUAL PURCHASE PRICE OF
McCook Reservoir Stage II Grout Curtain
28 23 29.00 03_ Existing Webcam System
24 VAC
3.3 Amps
Total Power: 80 Watts
Accessories: Heater: 50 Watts/Blower: 2 Watts Camera Power: 28 Watts Tools Required: .100” Flat Head Screwdriver Phillips Head Screwdriver 7/16” Wrench or Socket
3.3 amperios Energía Total: 80 vatios
Accesorios: Calentador: 50 Watts/Blower: 2 vatio Energía De la Cámara fotográfica: 28 vatios Las Herramientas Requirieron: Destornillador Principal Plano Del 100" Destornillador Principal Phillips
24 VCA
3.3 ampères Puissance Totale : 80 watts
Accessoires : Réchauffeur : 50 Watts/Blower : 2 watts Puissance D'Appareil-photo : 28 watts Les Outils besoin : Tournevis Principal Plat De 100" Tournevis Principal Phillips
3.3 Ampere
Gesamtenergie: 80 Watt
Zusatzgeräte: Heizung: 50 Watt/Blower: 2 Watt Kamera-Energie: 28 Watt Werkzeuge Erforderten: 100"Flacher Hauptschraubenzieher Kreuzkopfhauptschraubenzieher
3.3 ampères Poder Total: 80 watts
Acessórios: Calefator: 50 Watts/Blower: 2 watt Poder Da Câmera: 28 watt As Ferramentas Requereram: Chave de fenda Principal Lisa Do 100" Chave de fenda Principal Phillips
3.3 ampère Alimentazione Totale: 80 watt
Accessori: Riscaldatore: 50 Watts/Blower: 2 watt Alimentazione Della Macchina fotografica: 28 watt Attrezzi Richiesti: Cacciavite Capo Piano Del 100" Cacciavite Capo "phillips"
Electrical Specifications Power 24VAC Class 2 Only
PFD7CN-9
PFD7CS-9
Français
Deutsch
Italiano
Portuguese
Español
English
Contents of Box
*** Pan Tilt boxed separately along with its instructions.
McCook Reservoir Stage II Grout Curtain
28 23 29.00 03_ Existing Webcam System
Securely mount bracket to wall. Pull wiring through bracket and position grommet as shown.
• Con seguridad soporte del montaje a emparedar. Tire del cableado a través del soporte y del ojal de la posición según lo demostrado.
• Solidement parenthèse de bâti à murer. Tirez le câblage par la parenthèse et le canon isolant de position comme montré.
• Sicher Einfassung Haltewinkel wall. Ziehen Sie Verdrahtung durch Haltewinkel und Position Gummimuffe, wie gezeigt.
• Firmemente suporte da montagem a wall. Puxe a fiação através do suporte e do ilhó da posição como mostrado.
• Saldamente staffa del supporto da wall. Tiri i collegamenti tramite la staffa ed il gommino di protezione di posizione come indicato.
Screw the (2) bolts into the coupling.
• Atornille (2) los pernos en el acoplador.
• Vissez (2) les boulons dans l'accouplement.
• Schrauben Sie die (2) Schraubbolzen in die Koppe-lung.
• Parafuse (2) os parafusos no acoplamento.
• Avviti (2) i bulloni nell'accoppiamento.
Wrap Teflon tape around the pipe threads to ensure a tight seal.
• La cinta del Teflon del abrigo alrededor de la pipa rosca para asegurar un sello apretado.
• La bande de teflon d'enveloppe autour de la pipe filète pour assurer un joint serré.
• Verpackung Teflonklebeband um das Rohr verlegt, um eine feste Dichtung sicherzustellen.
• A fita adesiva do Teflon do envoltório em torno da tubulação enfía para assegurar um selo apertado.
• Il nastro del Teflon dell'involucro intorno al tubo filetta per accertare una guarnizione stretta.
TM
Screw the coupling onto the pipe threads until it is hand tight.
• Atornille el acoplador sobre los hilos de rosca de la pipa hasta que es mano firmemente.
• Vissez le couplage sur les fils de pipe jusqu'à ce que ce soit main fortement.
• Schrauben Sie die Koppelung auf die Rohrgewinde, bis es Hand fest ist.
• Parafuse o acoplamento nas linhas da tubulação até que esteja mão firmemente.
• Avviti l'accoppiamento sui filetti del tubo fino a che non sia fortemente mano.
SOLD SEPARATELY SOLD SEPARATELY
SOLD SEPARATELY SOLD SEPARATELY
McCook Reservoir Stage II Grout Curtain
28 23 29.00 03_ Existing Webcam System
Loop the lanyard over the set screw to temporarily hold housing.
• Coloque el acollador sobre el tornillo de presión para celebrar temporalmente la cubierta.
• Faites une boucle la lanière au-dessus de la vis de réglage pour tenir temporairement le logement.
• Schlingen Sie die Abzuglinie über der Klemmschraube, um Gehäuse vorübergehend zu halten.
• Dê laços no colhedor sobre o parafuso de fixação para prender temporariamente a carcaça.
• Colleghi la cordicella in circuito sopra la vite di arresto temporaneamente per tenere l'alloggiamento.
Make the appropriate wiring connections from the dome to the gooseneck.
• Haga las conexiones apropiadas del cableado de la bóveda al gooseneck.
• Établissez les rapports appropriés de câblage à partir du dôme au col de cygne.
• Stellen Sie die passenden Verdrahtung Beziehungen von der Haube zum gooseneck her.
• Faça as conexões apropriadas da fiação da abóbada ao gooseneck.
• Faccia i collegamenti adatti dei collegamenti dalla cupola al gooseneck.
Undo the lanyard, pull housing up and twist secure with the locking bolt and washers.
• Deshaga el acollador, tire de contener para arriba y tuerza seguro con el perno y las arandelas de fijación.
• Défaites la lanière, tirez loger vers le haut et tordez bloqué avec le boulon et les rondelles de fermeture.
• Annulieren Sie die Abzuglinie, ziehen Sie oben unterbringen und verdrehen Sie sicheres mit dem verriegelnschraubbolzen und den Unterlegscheiben.
• Undo o colhedor, puxe abrigar acima e torça seguro com o parafuso e as arruelas travando.
• Undo la cordicella, tiri l'alloggio in su e torca sicuro con il bullone e le rondelle di bloccaggio.
Slide the grommet down over the coupling to prevent water from entering and complete the assembly.
• Resbale el ojal abajo sobre el acoplador para evitar que el agua entre y para terminar a la asamblea.
• Glissez le canon isolant vers le bas au-dessus de l'accouplement pour empêcher l'eau d'entrer et pour accomplir l'assemblée.
• Schieben Sie die Gummimuffe unten über der Koppelung, um zu verhindern, daß Wasser und die Versammlung durchzuführen hereinkommt.
• Deslize o ilhó para baixo sobre o acoplamento para impedir que a água entre e para terminar o conjunto.
• Faccia scorrere il gommino di protezione giù sopra l'accoppiamento per impedire l'acqua entrare e per completare il complessivo.
SOLD SEPARATELY SOLD SEPARATELY
SOLD SEPARATELY SOLD SEPARATELY
McCook Reservoir Stage II Grout Curtain
28 23 29.00 03_ Existing Webcam System
RJ45
RJ45
24VAC
Camera/Heater/Blower
Camera/Heater/Blower
Yellow Green
SNC-RZ50/SNC-RZ30
28 Watts
52 Watts
1/0
Alarm 1
Common
Blue
Violet
A B
C
D
Wire as shown below for IP models:(PFD7CN-9; PFD7TN-9)
Make the appropriate male and female connec-tions. Indoor model does not include pre-run cables.
• Haga las conexiones masculinas y femeninas apropiadas. El modelo de interior no incluye pre-funciona los cables.
• Établissez les rapports masculins et femelles appropriés. Le modèle d'intérieur n'inclut pas pré-courent des câbles.
• Stellen Sie die passenden männlichen und weiblichen Beziehungen her. Innenmodell schließt nicht vor-laufen lassen Kabel ein.
• Faça as conexões masculinas e fêmeas apropriadas. O modelo indoor não inclui pre-funciona cabos.
• Faccia i collegamenti maschii e femminili adatti. Il modello dell'interno non include pre-fa funzionare i cavi.
MM2
AWG
,5 ,75 1,0 1,5 2,5 4 6 22 20 18 16 14 12 10
The beam angle may be adjusted on the bottom of the unit.
• Éstos se recomiendan las distancias máximas para 24VAC con una gota del voltage del 10%.
• Ceux-ci sont recommandés des distances maximum pour 24VAC avec une chute de tension de 10%.
• Diese werden maximale Abstände für 24VAC mit einem 10% Spannungsabfall empfohlen.
• Estes são recomendados distâncias máximas para 24VAC com uma queda de tensão de 10%.
• Questi sono suggeriti distanze massime per 24VAC con una differenza de potenziale di 10%.
These are recommended maximum distances for 24VAC with a 10% voltage drop.
Remove Pan/Tilt from shipping carton.
Install in base bracket in housing.
• Quite Pan/Tilt del cartón del envío. Instale en soporte bajo en la cubierta.
• Enlevez Pan/Tilt du carton d'expédition. Installez dans la parenthèse basse dans le logement.
• Entfernen Sie Pan/Tilt vom Verschiffenkarton. Bringen Sie in niedrigen Haltewinkel im Gehäuse an.
• Remova Pan/Tilt da caixa do transporte. Instale no suporte baixo na carcaça.
• Rimuova Pan/Tilt dalla scatola di trasporto. Installi in staffa bassa in alloggiamento.
A B
C
D
RJ45
RJ45
24VAC
Camera/Heater/Blower
Camera/Heater/Blower
Yellow
Green
SNC-RZ50/SNC-RZ30
13 Watts
52 Watts
1/0
RS-485RX A
RS-485RX B
RS-485TX A
RS-485TX B
Blue
Violet
Gray
White
Make the appropriate male and female connec-tions. Indoor model does not include pre-run cables.
• Haga las conexiones masculinas y femeninas apropiadas. El modelo de interior no incluye pre-funciona los cables.
• Établissez les rapports masculins et femelles appropriés. Le modèle d'intérieur n'inclut pas pré-courent des câbles.
• Stellen Sie die passenden männlichen und weiblichen Beziehungen her. Innenmodell schließt nicht vor-laufen lassen Kabel ein.
• Faça as conexões masculinas e fêmeas apropriadas. O modelo indoor não inclui pre-funciona cabos.
• Faccia i collegamenti maschii e femminili adatti. Il modello dell'interno non include pre-fa funzionare i cavi.
Wire as shown below for analog models: (PFD7CS-9; PFD7TS-9)
McCook Reservoir Stage II Grout Curtain
28 23 29.00 03_ Existing Webcam System
To install the dome align the tabs and twist counter clockwise to secure.
• Para instalar la bóveda alinee las lengüetas y tuerza al revés a la derecha para asegurar.
• Pour installer le dôme alignez les étiquettes et tordez contre dans le sens des aiguilles d'une montre pour fixer.
• Um die Haube anzubringen richten Sie die Vorsprünge aus und verdrehen Sie sich entgegengesetzt nach rechts um zu sichern.
• Para instalar a abóbada alinhe as abas e torça-as contra no sentido horário para fixar-se.
• Per installare la cupola allinei le linguette e torca contro in senso orario per fissare.
Hand tighten the screws on the dome.
Recommended torque 12 inches/lb (1.35Nm).
• La mano aprieta los tornillos en la bóveda. Esfuerzo de torsión recomendado 12 inches/lb (el 1.35Nm).
• La main serrent les vis sur le dôme. Couple recom-mandé 12 inches/lb (1.35Nm).
• Hand ziehen die Schrauben an der Haube fest.
Empfohlene Drehkraft 12 inches/lb (1.35Nm).
• A mão aperta os parafusos na abóbada. Torque recomendado 12 inches/lb (1.35Nm).
• La mano stringe le viti sulla cupola. Coppia di torsione suggerita 12 inches/lb (1.35Nm).
When pressurizing unit be sure to set the guage or regulator from 10-20psi (.7-1.4bar).
• Al presurizar la unidad sea seguro fijar la medida o el regulador de 10-20psi (7-1.4bar).
• En pressurisant l'unité soyez sûr de placer la jauge ou le régulateur de 10-20psi (7-1.4bar).
• Wenn Sie Maßeinheit unter Druck setzen, seien Sie sicher, das Eichmaß oder den Regler von 10-20psi (7-1.4bar) einzustellen.
• Ao pressurizar a unidade seja certo ajustar o guage ou o regulador de 10-20psi (7-1.4bar).
• Nel pressurizzare l'unità sia sicuro regolare il misuratore o il regolatore da 10-20psi (7-1.4bar).
PSI0
Nitrogen Tank
Hose
Regulator
Air Chuck Fitting
CAPTIVE SCREW
To secure in place, tighten captive screw.
• Para asegurar en lugar, apriete el tornillo prisionero.
• Pour fixer en place, serrez la vis captive.
• Um im Platz zu sichern, ziehen Sie Sicherheitsschraube fest.
• Para fixar-se no lugar, aperte o parafuso prisioneiro.
• Per fissare sul posto, stringa la vite prigioniera.
McCook Reservoir Stage II Grout Curtain
28 23 29.00 03_ Existing Webcam System
Place the air chuck on the tank valve and begin filling until pressure relief valve opens.
• Coloque la tirada del aire en la válvula del tanque y comience a llenar hasta que la válvula de descarga de presión se abre.
• Placez le mandrin d'air sur la valve de réservoir et commencez à remplir jusqu'à ce que la valve de décompression s'ouvre.
• Setzen Sie die Luftklemme auf das Behälterventil und fangen Sie an zu füllen, bis Druckablaßventil sich öffnet.
• Coloque o mandril do ar na válvula do tanque e comece a encher-se até que a válvula de escape de pressão abra.
• Disponga il mandrino dell'aria sulla valvola del carro armato e cominci a riempirsi fino a che la valvola limitatrice della pressione non si apra.
Air Chuck
Tank Valve
Open the relief valve. Drain all air from the housing and repeat twice to remove all moisture.
• Abra la válvula de descarga. Drene todo el aire de la cubierta y de la repetición dos veces para quitar toda la humedad.
• Ouvrez la soupape de sécurité. Évacuez tout l'air le logement et la répétition deux fois pour enlever toute l'humidité.
• Öffnen Sie das Sicherheitsventil. Lassen Sie alle Luft aus dem Gehäuse und der Wiederholung zweimal ab, um alle Feuchtigkeit zu entfernen.
• Abra a válvula de escape. Drene todo o ar da carcaça e do repeat duas vezes para remover toda a umidade.
• Apra la valvola di sfiato. Vuoti due volte tutta l'aria dall'alloggiamento e dalla ripetizione per rimuovere tutta l'umidità.
The beam angle may be adjusted on the bottom of the unit.
• Energía encima de la unidad.
• Puissance vers le haut de l'unité.
• Energie herauf die Maßeinheit.
• Poder acima da unidade.
• Alimentazione sull'unità.
Power up the unit. After purging check the housing pressure. It should be around 5psi (.34bar).
• Después de purgar el cheque la presión de la cubierta.
Debe estar alrededor de 5psi (34bar).
• Après la purge du contrôle la pression de logement. Elle devrait être autour de 5psi (34bar).
• Nachdem Überprüfung der Gehäusedruck bereinigt worden ist. Sie sollte um 5psi (34bar) sein.
• Após ter removido a verificação a pressão da carcaça.
Deve ser em torno de 5psi (34bar).
• Dopo l'eliminazione dell'inceppo del controllo la pressione dell'alloggiamento. Dovrebbe essere intorno a 5psi (34bar).
PSI0
McCook Reservoir Stage II Grout Curtain
28 23 29.00 03_ Existing Webcam System
PRESSURIZED HO
USIN
G
Replacem ent Parts List
Part N o.
D escription
R
P P
FD
T02
H ousing Top (E xtended)
R
P V
L1938 R em ovable P endent C oupling
R
P V
L1802 P lastic R ain S hroud
R
P V
L1795 Tank Valve G asket
R
P 96R
S O
R G
M ain O -R ing 9.25"
R
P P
FD
TR
Trim
R ing w
/o D om e
R
C P
FD
C lear D om e w ith sealing O -R ing
7b R
C
TP
FD
Tinted D om e w ith sealing O
-R ing
R
P P
FD
T03
Internal S ealing B racket A ssem bly
R
P 96R
S O
R G
S m all O
-R ing 4.5"
R
P 70P
T07a H erm etic C onnector, G asket, C able
R
P
95VA
LV
5 to 7 psi P ressure R elief Valve
R
P
95VA
LV
Tank Valve
R
P
FD
24VA
C H eater
R
P 46P
K H
S pacers P acket
R
P
FD
C onnection P C
B
R
P
FD
M ain B racket A ssem bly
R
P
FD
B low er
N /S
R P
40C A
P P
FD
E xternal Input Video/P ow er C ables
N /S
R P
46P K
H
P acket A ssem bly-H ardw are
N /S
R P
46P K
E
P acket A ssem bly-E lectrical
R P
V L2857
P /T B ase B racket
R
P 76v385A
P /T C onnection C ard (N etw ork M odels O nly)
R
P V
L3097
IP
C ard B racket
R
P 70p14015
IP
C ard
R
P 96P
S G
K
P /T G rom m et (2)
R
P 76P
0F060E
IP
C onnection C ard (N etw ork M odels O nly)
(N etw ork M odels O nly)
N /S
W M
20G G
O O
S E
N E
C K
(S O
LD
S
E P
A R
A
TE
LY)
McCook Reservoir Stage II Grout Curtain
28 23 29.00 03_ Existing Webcam System
All contents are Copyright © 1992–2006 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Data Sheet
Cisco Aironet 1240AG Series 802.11A/B/G Access Point
Cisco ® Aironet ® 1240AG Series Access Points deliver the versatility, high capacity, security, and enterprise-class features demanded by WLAN customers. These IEEE 802.11a/b/g access points are designed specifically for challenging RF environments such as factories, warehouses, and large retail establishments that require the antenna versatility associated with connectorized antennas, a rugged metal enclosure, and a broad operating temperature range. The Cisco Aironet 1240AG
Series provides local as well as inline power, including support for IEEE 802.3af Power over Ethernet (PoE).
The Cisco Aironet 1240AG Series is a component of the Cisco Unified Wireless Network, a comprehensive solution that delivers an integrated, end-to-end wired and wireless network. Using the radio and network management features of the Cisco Unified Wireless Network for simplified deployment, the Cisco Aironet 1240AG Series extends the security, scalability, reliability, ease of deployment, and manageability available in wired networks to the wireless LAN.
The Cisco Aironet 1240AG Series is available in two versions: unified or autonomous. Unified access points operate with the Lightweight Access
Point Protocol (LWAPP) and work in conjunction with Cisco wireless LAN controllers and the Cisco Wireless Control System (WCS). When configured with LWAPP, the Cisco Aironet 1240AG Series can automatically detect the best-available Cisco wireless LAN controller and download appropriate policies and configuration information with no manual intervention. Autonomous access points are based on Cisco IOS® Software and may optionally operate with the CiscoWorks Wireless LAN Solution Engine (WLSE). Autonomous access points, along with the CiscoWorks
WLSE, deliver a core set of features and may be field-upgraded to take advantage of the full benefits of the Cisco Unified Wireless Network as requirements evolve.
McCook Reservoir Stage II Grout Curtain
28 23 29.00 03_ Existing Webcam System
© 2006 Cisco Systems, Inc. All rights reserved.
Important notices, privacy statements, and trademarks of Cisco Systems, Inc. can be found on cisco.com.
AWARD-WINNING SECURITY
The Cisco Aironet 1240AG Series is listed on the National Institute of Standards and Technology (NIST) FIPS 140-2 Pre-Validation List and is in process for Information Assurance validation under the National Information Assurance Partnership (NIAP) Common Criteria program.
The Cisco Aironet 1240AG Series supports 802.11i, Wi-Fi Protected Access (WPA), WPA2, and numerous Extensible Authentication Protocol
(EAP) types. WPA and WPA2 are the Wi-Fi Alliance certifications for interoperable, standards-based WLAN security. These certifications support
IEEE 802.1X for user-based authentication, Temporal Key Integrity Protocol (TKIP) for WPA encryption, and Advanced Encryption Standard
(AES) for WPA2 encryption. These certifications help to ensure interoperability between Wi-Fi-certified WLAN devices from different manufacturers.
The Cisco Aironet 1240AG Series hardware-accelerated AES encryption supports enterprise-class, government-grade secure encryption over the
WLAN without compromising performance. IEEE 802.1X authentication helps to ensure that only authorized users are allowed on the network.
Backward compatibility and support for WPA client devices running TKIP, the RC4 encryption algorithm, is also supported by the Cisco Aironet
1240AG Series.
Cisco Aironet 1240AG Series Access Points operating with LWAPP support Cisco Unified Intrusion Detection System/Intrusion Prevention System
(IDS/IPS), a software feature that is part of the Cisco Self-Defending Network and is the industry’s first integrated wired and wireless security solution. Cisco Unified IDS/IPS takes a comprehensive approach to security—at the wireless edge, wired edge, WAN edge, and through the data center. When an associated client sends malicious traffic through the Cisco Unified Wireless Network, a Cisco wired IDS device detects the attack and sends shun requests to Cisco wireless LAN controllers, which will then disassociate the client device.
Autonomous or unified Cisco Aironet 1240AG Series Access Points support management frame protection for the authentication of 802.11 management frames by the wireless network infrastructure. This allows the network to detect spoofed frames from access points or malicious users impersonating infrastructure access points.