087100_FL.pdf
PDF 117 KB Posted
- Attached to
- Install Security Door- BLDG 128 Federal contract opportunity
- Solicitation number
- W912JB-18-R-5010
About this file
Specs 087100
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Site_Visit_Minutes_128_door.pdf | ||
| site_visit_attendance_12807-17-2018-140922.pdf | ||
| amendment_2.pdf | ||
| NAICS_amendment.pdf | ||
| 088000.pdf | ||
| 055000_FL.pdf | ||
| 099123_FL.pdf | ||
| 092216_FL.pdf | ||
| Vetting_Access_Request_List.pdf | ||
| 084113.pdf | ||
| 172013_-_Install_Security_Dr_B-128_Sheet_1_dwg.pdf | ||
| 092900_FL.pdf | ||
| Final_Solicitation.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SELFRIDGE ANGB, MICHIGAN
08 71 00 1 DOOR HARDWARE
SECTION 08 71 00 – DOOR HARDWARE
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes: Finish Hardware for door openings, except as otherwise specified herein.
1. Door hardware for aluminum doors.
2. Door hardware for other doors indicated.
3. Keyed cylinders as indicated.
B. Related Sections:
1. Division 6: Rough Carpentry.
2. Division 8: Aluminum Doors and Frames.
3. Division 26: Electrical.
4. Division 28: Electronic Security.
C. References: Comply with applicable requirements of the following standards. Where these standards conflict with other specific requirements, the most restrictive shall govern.
1. Builders Hardware Manufacturing Association (BHMA).
2. NFPA 101 Life Safety Code.
3. NFPA 80 Fire Doors and Windows.
4. ANSI-A156.xx Various Performance Standards for Finish Hardware.
5. UL10C Positive Pressure Fire Test of Door Assemblies.
6. ANSI-A117.1 Accessible and Usable Buildings and Facilities.
7. DHI /ANSI A115.IG Installation Guide for Doors and Hardware.
D. Intent of Hardware Groups:
1. Should items of hardware not definitely specified be required for completion of the Work, furnish such items of type and quality comparable to adjacent hardware and appropriate for service required.
2. Where items of hardware aren’t definitely or correctly specified, are required for completion of the Work, a written statement of such omission, error, or other discrepancy to the Contracting Officer, prior to date specified for receipt of bids for clarification by addendum;
or, furnish such items in the type and quality established by this specification, and appropriate to the service intended.
E. N/A
F. Alternates: Refer to Division 1 for Alternates and procedures.
08 71 00 2 DOOR HARDWARE
1.2 SUBSTITUTIONS
A. Comply with Division 1.
1.3 SUBMITTALS
A. Comply with Division 1.
B. Special Submittal Requirements: Combine submittals of this Section with Sections listed below to ensure the "design intent" of the system/assembly is understood and can be reviewed together.
C. Product Data: Manufacturer's specifications and technical data including the following:
1. Detailed specification of construction and fabrication.
2. Manufacturer's installation instructions.
3. Wiring diagrams for each electric product specified. Coordinate voltage with electrical before submitting.
4. Submit 6 copies of catalog cuts with hardware schedule.
D. Shop Drawings - Hardware Schedule: Submit six complete reproducible copy of detailed hardware schedule in a vertical format.
1. List groups and suffixes in proper sequence.
2. Completely describe door and list architectural door number.
3. Manufacturer, product name, and catalog number.
4. Function, type, and style.
5. Size and finish of each item.
6. Mounting heights.
7. Explanation of abbreviations and symbols used within schedule.
8. Detailed wiring diagrams, specially developed for each opening, indicating all electric hardware, security equipment and access control equipment, and door and frame rough-ins required for specific opening.
E. Templates: Submit templates and "reviewed Hardware Schedule" to door and frame supplier and others as applicable to enable proper and accurate sizing and locations of cutouts and reinforcing.
1. Templates, wiring diagrams and "reviewed Hardware Schedule" of electrical terms to electrical for coordination and verification of voltages and locations.
F. Samples:
1. One sample of Lever and Rose/Escutcheon design, (pair).
2. Three samples of metal finishes.
G. Contract Closeout Submittals: Comply with Division 1 including specific requirements indicated.
08 71 00 3 DOOR HARDWARE
1. Operating and maintenance manuals: Submit three sets containing the following.
a. Complete information in care, maintenance, and adjustment, and data on repair and replacement parts, and information on preservation of finishes.
b. Catalog pages for each product.
c. Name, address, and phone number of local representative for each manufacturer.
d. Parts list for each product.
e. Copy of final hardware schedule, edited to reflect, "As installed".
f. Copy of final keying schedule.
g. As installed “Wiring Diagrams” for each piece of hardware connected to power, both low voltage and 110 volts.
h. One set of special tools required for maintenance and adjustment of hardware, including changing of cylinders.
1.4 QUALITY ASSURANCE
A. Comply with Division 1.
1. Statement of qualification for distributor and installers.
2. Statement of compliance with regulatory requirements and single source responsibility.
3. Distributor's Qualifications: Firm with 3 years experience in the distribution of commercial hardware.
a. Distributor to employ full time Architectural Hardware Consultants (AHC) for the purpose of scheduling and coordinating hardware and establishing keying schedule.
b. Hardware Schedule shall be prepared and signed by an AHC.
4. Installer's Qualifications: Firm with 3 years experienced in installation of similar hardware to that required for this Project, including specific requirements indicated.
5. Regulatory Label Requirements: Provide testing agency label or stamp on hardware for labeled openings.
a. Provide UL listed hardware for labeled and 20-minute openings in conformance with requirements for class of opening scheduled.
b. Underwriters Laboratories requirements have precedence over this specification where conflict exists.
6. Single Source Responsibility: Except where specified in hardware schedule, furnish products of only one manufacturer for each type of hardware.
B. Review Project for extent of finish hardware required to complete the Work. Where there is a conflict between these Specifications and the existing hardware, notify the Contracting Officer in writing and furnish hardware in compliance with the Specification unless otherwise directed in writing by the Contracting Officer.
08 71 00 4 DOOR HARDWARE
1.5 DELIVERY, STORAGE, AND HANDLING
A. Packing and Shipping: Comply with Division 1.
1. Deliver products in original unopened packaging with legible manufacturer's identification.
2. Package hardware to prevent damage during transit and storage.
3. Mark hardware to correspond with "reviewed hardware schedule".
4. Deliver hardware to door and frame manufacturer upon request.
B. Storage and Protection: Comply with manufacturer's recommendations.
1.6 PROJECT CONDITIONS
A. Coordinate hardware with other work. Furnish hardware items of proper design for use on doors and frames of the thickness, profile, swing, security and similar requirements indicated, as necessary for the proper installation and function, regardless of omissions or conflicts in the information on the Contract Documents.
B. Door and frame prep: Before hardware installation, verify that all doors and frames are properly prepared to receive the specified hardware. Hollow metal frames shall be prepared for ANSI strike plates per A115.1-2 (4-7/8" high), hinge preps will be mortised and reinforced with a minimum of 10 gauge reinforcement material; minimum of 14 gauge reinforcement material for closer. Hollow metal doors shall be properly prepared and reinforced with a minimum of 16 gauge material for either mortised or cylindrical locks as specified. It is preferred that all hollow metal doors receiving door closers have 14 gauge reinforcement. If this is not possible, the use of sex bolts is mandatory. Review Shop Drawings for doors and entrances to confirm that adequate provisions will be made for the proper installation of hardware.
1.7 WARRANTY
A. Refer to Conditions of the Contract.
B. Manufacturer’s Warranty:
1. Closers: 10 years.
2. Exit Devices: 3 years.
3. Locksets and Cylinders: 3 years.
4. All other Hardware: 2 years.
1.8 OPERATING AND MAINTENANCE
A. Instruct Government’s personnel in operation and maintenance of hardware units.
1.9 MAINTENANCE
A. Extra Service Materials: Deliver to Contracting Officer extra materials from same production run as products installed. Package products with protective covering and identify with descriptive labels.
Comply with Division 1 Closeout Submittals Section.
08 71 00 5 DOOR HARDWARE
1. Special Tools: Provide special wrenches and tools applicable to each different or special hardware component.
2. Maintenance Tools: Provide maintenance tools and accessories supplied by hardware component manufacturer.
3. Delivery, Storage and Protection: Comply with requirements for delivery, storage and protection of extra service materials.
B. Maintenance Service: Submit maintenance service agreement for electronic products installed.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. The following manufacturers are approved subject to compliance with requirements of the Contract Documents. Approval of manufacturers other than those listed shall be in accordance with Division 1.
DOOR HARDWARE
Description Manufacturer Model / Series Finish
Hanging Devices
Continuous Hinge Stanley 661HD/662HD (Geared Type) 628
Alternate Hager/Roton 780-112HD/780-224HD 628
Mortise Hinge Stanley FBB/CB199 x NRP (Heavy use exterior) 626 FBB/CB191 X NRP (Standard use exterior) 626 FBB/CB168 (Heavy use interior) 652
FBB/CB179 (Standard use interior) 652
• NRP at out swinging doors
Securing Devices
Mortise Lock Set Best Mortise - 45H Series, Verify trim design 630
Cylindrical Lock Set Best Cylindrical - 93K-S3 Series, Verify trim design 626
Description Manufacturer Model / Series Finish
Lock Function Room type
45H-N (93KN) Passage Function
08 71 00 6 DOOR HARDWARE
Alternate No Substitute
Auxiliary Dead Locks Best Mortise – 48H (function as required) 626
Tubular- 83T (function as required) 626
Alternate No Substitution
Keying Best Existing "Standard" lnterchangble Core 626
Exit Device Von Duprin CD35A-NL-OP X Pull (narrow door exterior) 626 CD98NL (single door, exterior) 630 CD98NL-OP x Pull X CD98EO X KR4954 (pair, ext) 630 CD3547A-NL-OP x Pull X CD3547A-EO 626
(narrow pr, ext) CD9847NL-OP x Pull X CD9847EO x Pull (Pr, ext) 630 98L-F (rated single door interior) 630 9827L-F X LBR X 9827EO-F X LBR (pr, interior) 630 350 Series Dummy Bar (interior vestibule) 630
• All non-rated exit devices to have hex key dogging
• Vandal Resistant Lever
• SNB
• Offset wire pulls as required
Coordinator Rockwood 1600 Series x Filler Bar x 2/1601AB or 2/1601C 600
Alternate Trimco 3094 Series x Filler Bar x 2/3095 or 2/3096 600 Description Manufacturer Model / Series Finish
Automatic Flush Bolts Rockwood 1842/1845 (Automatic) (metal doors) 626
Alternate Trimco 3810 x 3810 (Automatic) (metal doors) 626
Manual Flush Bolts Rockwood 555 (Manual) (metal doors) 626
Alternate Trimco 555 (Manual) (metal doors) 626
08 71 00 7 DOOR HARDWARE
Closing Device
Surface Closer LCN 4041 EDA (exterior outswinging) 689 4041EDA, 4041 REG (interior) 689
• All door frames to be reinforced
• Hold-open arms HSCNS or H-EDA as required
• Auxiliary stops recommended
Stops & Holders
Overhead Door Holder ABH 1000 Series (Overhead Concealed-Heavy duty) 630 9000 Series (Overhead Concealed-Heavy duty) 630
Alternate Glynn Johnson 100 Series (Overhead Concealed-Heavy duty) 630 900 Series (Overhead Concealed-Heavy duty) 630
Door Stop Rockwood 403/409 Wall Stop (Interior) 626 480 (Interior/Exterior Floor) 626
• Allow for maximum swing of doors
• Backing required at wall stops
• Avoid floor stops where possible
Alternate Trimco 1270CVCP (Wall Stop)
1211 (Interior Floor) 626 1214 (Interior/Exterior Floor)
• Allow for maximum swing of doors
• Backing required at wall stops
• Avoid floor stops where possible
Description Manufacturer Model / Series Finish
Accessories
Push I Pull Plate Rockwood 70C x 106-6" x 70C 4x 16 (CFC where required) 630
Alternate
Trimco
1001-3 x 10138 4 x 16 (CFC where required)
Kick Plate
Rockwood
K1050 10" x 2" LOW x .050 x CSK (Single doors)
Alterrnate
K0050 10" x 2" LOW x .050 x CSK (Single doors)
08 71 00 8 DOOR HARDWARE
Mop Plate
K1050 4" x 1" LOW x .050 x CSK (Single doors)
KM050 4" x 1" LOW x .050 x CSK (Single doors)
Door Silencer
608 (Metal Frames
Gray
1229A (Metal Frames
Gray
Thresholds
Reese
S205A (verify per details)
Pemko
171A (verify per details)
Gasketing
Reese
7978 (at head and jambs)
Pemko
S880 (at head and jambs)
DOOR HARDWARE
Description Manufacturer Model / Series _______Finish
• Applications may vary
Alternate Pemko 303AS (at head and jambs- surface mount) 315CN (at sill on door- surface mount)
• Applications may vary
Alternate National Guard 161SA (at head and jambs –surface mount) 200SA (at sill on door – surface mount)
Astragal Reese Astragal by door manufacturer at HM door.
Alternate Pemko 355CS x HS1000 (Wood Doors) (Where required by fire code)
• Astragal by door manufacturer at HM door.
Sound Seal Reese DS78A (at head and jambs) 370A (at sill on door – mortise)
• Applications may vary.
Alternate Pemko 312CR (at head and jambs) 411ASL (at sill on door – mortise)
• Applications may vary.
08 71 00 9 DOOR HARDWARE
Drip Cap Reese R201A (4” wider than door width)
Alternate Pemko 16A (4” wider than door width)
MATERIALS
B. Hinges: Shall be Five Knuckle Ball bearing hinges.
1. Template screw hole locations.
2. Bearings are to be fully hardened.
3. Bearing shell is to be consistent shape with barrel.
4. Minimum of two permanently lubricated non-detachable bearings on standard weight hinge and four permanently lubricated bearing on heavy weight hinges.
5. Equip with easily seated, non-rising pins.
6. Non-removable pin screws shall be slotted stainless steel screws.
7. Hinges shall be full polished, front, back and barrel.
8. Hinge pin is to be fully plated.
9. Bearing assembly is to be installed after plating.
10. Sufficient size to allow 180-deg swing of door.
11. Furnish five knuckles with flush ball bearings.
12. Provide hinge type as listed in schedule.
13. Furnish three hinges per leaf to 7-foot 6-inch height. Add one for each additional 30 inches in height or fraction thereof.
14. Tested and approved by BHMA for all applicable ANSI Standards for type, size, function and finish.
15. UL10C listed for Fire.
C. Geared Continuous Hinges:
1. Tested and approved by BHMA for ANSI A 156.26-1996 Grade 1.
2. Anti-spinning through fastener.
3. UL10C listed for 3-hour fire rating.
4. Non-handed.
5. Lifetime warranty.
6. Provide fire pins for 3-hour fire ratings.
7. Sufficient size to permit door to swing 180 deg.
D. Mortise Type Locks and Latches:
1. Tested and approved by BHMA for ANSI A 156.13, Series 1000, Operational Grade 1, Extra-Heavy Duty, Security Grade 2 and be UL10C.
2. Fit ANSI A 115.1 door preparation.
3. Functions and design as indicated in the hardware groups.
4. Solid, one-piece, 3/4-inch (19-mm) throw, anti-friction latchbolt made of self-lubricating stainless steel.
5. Deadbolt functions shall have 1 inch (25 mm) throw bolt made of hardened stainless steel.
6. Latchbolt and deadbolt are to extend into the case a minimum of 3/8 inch (9.5 mm) when fully extended.
7. Auxiliary deadlatch to be made of one piece stainless steel, permanently lubricated.
8. Provide sufficient curved strike lip to protect door trim.
08 71 00 10 DOOR HARDWARE
9. Lever handles must be of forged or cast brass, bronze or stainless steel construction and conform to ANSI A 117.1. Levers that contain a hollow cavity are not acceptable.
10. Lock shall have self-aligning, thru-bolted trim.
11. Levers to operate a roller bearing spindle hub mechanism.
12. Mortise cylinders of lock shall have a concealed internal setscrew for securing the cylinder to the lockset. The internal setscrew will be accessible only by removing the core, with the control key, from the cylinder body.
13. Spindle to be designed to prevent forced entry from attacking of lever.
14. Provide locksets with 7-pin removable and interchangeable core cylinders.
15. Each lever to have independent spring mechanism controlling it.
16. Core face must be the same finish as the lockset.
E. Exit Devices Shall:
1. Tested and approved by BHMA for ANSI 156.3, Grade 1.
2. Provide a deadlocking latchbolt.
3. Non-fire rated exit devices shall have cylinder dogging.
4. Touchpad shall be “T” style.
5. Exposed components shall be of architectural metals and finishes.
6. Lever design shall match lockset lever design.
7. Provide strikes as required by application.
8. Fire exit devices to be listed for UL10C.
9. UL listed for Accident Hazard.
10. Provide vandal resistant or breakaway trim.
11. Aluminum vertical rod assemblies are acceptable only when provide with the manufacturers optional top and bottom stainless steel rod guard protectors.
F. Cylinders:
1. Provide the necessary cylinder housings, collars, rings and springs as recommended by the manufacturer for proper installation.
2. Provide the proper cylinder cams or tail piece as required to operate all locksets and other keyed hardware items listed in the hardware sets.
3. Coordinate and provide as required for related sections.
G. Door Closers Shall:
1. Tested and approved by BHMA for ANSI 156.4, Grade 1.
2. UL10C certified.
3. Closer shall have extra-duty arms and knuckles.
4. Conform to ANSI 117.1.
5. Maximum 2-7/16-inch case projection with non-ferrous cover.
6. Separate adjusting valves for closing and latching speed, and backcheck.
7. Provide adapter plates, shim spacers and blade stop spacers as required by frame and door conditions.
8. Full rack and pinion type closer with 1-1/2-inch minimum bore.
9. Mount closers on non-public side of door, unless otherwise noted in specification.
10. Closers shall be non-handed, non-sized and multi-sized.
H. Door Stops: Provide a dome floor or wall stop for every opening as listed in the hardware sets.
1. Wall stop and floor stop shall be wrought bronze, brass or stainless steel.
2. Provide fastener suitable for wall construction.
3. Coordinate reinforcement of walls where wall stop is specified.
08 71 00 11 DOOR HARDWARE
4. Provide dome stops where wall stops are not practical. Provide spacers or carpet riser for floor conditions encountered.
I. Over Head Stops: Provide a Surface mounted or concealed overhead when a floor or wall stop cannot be used or when listed in the hardware set.
1. Concealed overhead stops shall be heavy duty bronze or stainless steel.
2. Surface overhead stops shall be heavy duty bronze or stainless steel.
J. Push Plates: Provide with four beveled edges ANSI J301, 0.050 thickness, size as indicated in hardware set. Furnish oval-head countersunk screws to match finish.
K. Pulls with Plates: Provide with four beveled edges ANSI J301, 0.050 thickness Plate s with ANSI J401 Pull as listed in hardware set. Provide proper fasteners for door construction.
L. Push Pull Bars: Provide ANSI J504, 0.1-inch diameter pull and push bar model and series as listed in hardware set. Provide proper fasteners for door construction.
M. Kickplates: Provide with four beveled edges ANSI J102, 10 inches high by width less 2 inches on single doors and 1 inch on pairs of doors. Furnish oval-head countersunk screws to match finish.
N. Mop Plates: Provide with four beveled edges ANSI J103, 4 inches high by width less 1 inch on single doors and 1 inch on pairs of doors. Furnish oval-head countersunk screws to match finish.
O. Door Bolts: Flush bolts for wood or metal doors.
1. Provide a set of Automatic bolts ANSI/BHMA 156.3 Type 25 for hollow metal label doors.
2. Provide a set of Automatic bolts ANSI/BHMA 156.3 Type 27 at wood label doors.
3. Manual flush bolts ANSI/BHMA 156.16 at openings where allowed local authority.
4. Provide Dust Proof Strike ANSI/BHMA 156.16 at doors with flush bolts without thresholds.
P. Coordinator and Brackets: Provide a surface mounted coordinator when automatic bolts are used in the hardware set.
1. Coordinator shall comply with ANSI/BHMA A1156.3 Type 21A full width of the opening.
2. Provide mounting brackets for soffit applied hardware.
3. Provide hardware preparation (cutouts) for latches as necessary.
Q. Power Supply (14): Provide power supply for (ELR) Electric Latch Retraction exit devices
1. Motherboard will accept up to four plug-in Control Modules. Provide the appropriate necessary control module to operate the number of ELR exit devices used at each opening.
The Control Module shall include a Time delay Feature, variable (0 to 4 minutes) latch retraction period in response to a momentary input.
2. UL Listed for Class II output
3. Include circuit breakers for protection of motherboard,
4. 115- or 230-Volt user selectable switch, with AC input equals 115-volt at 1 amp.
5. Control module shall include fire alarm terminal and auxiliary contacts for remote signaling.
6. Optional card for Battery Backup (BT) power tap module to operate a card reader or when
ELR devices require battery backup (lead acid batteries are not included and is to be furnished by others).
7. Precision ELR150 Series with the required modules.
R. Power Transfer (7): Power transfer device shall be a steel housing and flexible tube. Secure and inconspicuous channel is to bring power from the frame to the door.
08 71 00 12 DOOR HARDWARE
1. Precision EPT-5.
2. Tube shall accept up to 5/16-inch wire bundle and accommodate a door swing of 120 deg.
3. Wires as required by others.
S. Electric Door Strike: ANSI/BHMA 156.31, Grade 1. and listed for Burglary Protection ANSI/UL1034 Grade 1.
1. For General use provide fail-secure electric strike and with fire-rated device.
2. Listed UL10C-1997 fire door assemblies.
3. Latchbolt monitor switch option when specified in hardware sets.
4. Provide the electric strike in the appropriate model that will accept a 5/8-inch or 3/4-inch latchbolt.
T. Door Position Switch: Provide door position switch for door status monitoring as indicated in hardware sets.
1. At all fired rated doors the door and frame hardware preparation will be provided by the door and frame manufacturer or by an authorized label service agent.
U. Seals: All seals shall be finished to match adjacent frame color. Seals shall be furnished as listed in schedule. Material shall be UL listed for labeled openings.
V. Weatherstripping: Provide at head and jambs only those units where resilient or flexible seal strip is easily replaceable. Where bar-type weatherstrip is used with parallel arm mounted closers install weatherstrip first.
1. Weatherstrip shall be resilient seal of (neoprene, polyurethane, vinyl, pile, nylon brush, silicone).
2. UL10C positive pressure rated seal set when required.
W. Door Bottoms/Sweeps: Surface mounted or concealed door bottom where listed in the hardware sets.
1. Door seal shall be resilient seal of (neoprene, polyurethane, nylon brush, silicone).
2. UL10C positive pressure rated seal set when required.
X. Thresholds: Thresholds shall be aluminum beveled type with maximum height of 1/2 inch for conformance with ADA requirements. Furnish as specified and per details. Provide fasteners and screws suitable for floor conditions.
Y. Key Control: Provide one wall mounted key cabinet complete with hooks, index and tags. Hook quantity shall be 50 percent over lock quantity.
Z. Silencers: Furnish silencers on all interior frames, three for single doors, two for pairs. Omit where any type of seals occur.
2.2 FINISH
A. Designations Used in Schedule of Finish Hardware: 3.5, and elsewhere to indicate hardware finishes are those listed in ANSI/BHMA A 156.18 including coordination with traditional U.S. finishes shown by certain manufacturers for their products.
B. Powder coat door closers to match other hardware, unless otherwise noted.
08 71 00 13 DOOR HARDWARE
C. Aluminum items shall be finished to match predominant adjacent material. Seals to coordinate with frame color.
2.3 KEYS AND KEYING
A. Provide keyed brass construction cores and keys during the construction period. Construction control and operating keys and core shall not be part of the Government's permanent keying system or furnished in the same keyway (or key section) as the Government's permanent keying system.
Permanent cores and keys (prepared according to the accepted keying schedule) will be furnished to the Contracting Officer.
B. Cylinders, Removable and Interchangeable Core System: Best Standard 7-pin.
C. Permanent Keys and Cores: Stamped with the applicable key mark for identification. These visual key control marks or codes will not include the actual key cuts. Permanent keys will also be stamped "Do Not Duplicate."
D. Transmit Grand Masterkeys, Masterkeys, and other security keys to Contracting Officer by registered mail, return receipt requested.
E. Furnish keys in the following quantities:
1. 1 each Grand Masterkeys.
2. 2 each Control keys.
3. 4 each Masterkeys.
4. 3 each Change keys each keyed core.
5. 15 each Construction Masterkeys.
6. 2 each Construction Control keys.
F. The Government will install permanent cores and return the construction cores to the Hardware Supplier. Construction cores and keys remain the property of the Hardware Supplier.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Verification of conditions: Examine doors, frames, related items and conditions under which Work is to be performed and identify conditions detrimental to proper and or timely completion.
1. Do not proceed until unsatisfactory conditions have been corrected.
3.2 HARDWARE LOCATIONS
A. Mount hardware units at heights indicated in the following publications except as specifically indicated or required to comply with the governing regulations.
1. Recommended Locations for Builder’s Hardware for Standard Steel Doors and Frames, by the Door and Hardware Institute (DHI).
2. Recommended locations for Architectural Hardware for flush wood doors (DHI).
3. WDMA Industry Standard I.S.-1A-04, Industry Standard for Architectural wood flush doors.
08 71 00 14 DOOR HARDWARE
3.3 INSTALLATION
A. Install each hardware item per manufacturer's instructions and recommendations. Do not install surface mounted items until finishes have been completed on the substrate. Set units level, plumb and true to line and location. Adjust and reinforce the attachment substrate as necessary for proper installation and operation.
B. Conform to local governing agency security ordinance.
C. Install Conforming to ICC/ANSI A 117.1 Accessible and Usable Building and Facilities.
D. Installed hardware using the manufacturers fasteners provided. Drill and tap all screw holes located in metallic materials. Do not use “Riv-Nuts” or similar products.
3.4 FIELD QUALITY CONTROL AND FINAL ADJUSTMENT
A. Contractor/Installers, Field Services: After installation is complete, Contractor shall inspect the completed door openings on site to verify installation of hardware is complete and properly adjusted, in accordance with both the Contract Documents and final Shop Drawings.
1. Check and adjust closers to ensure proper operation.
2. Check latchset, lockset, and exit devices are properly installed and adjusted to ensure proper operation.
a. Verify levers are free from binding.
b. Ensure latchbolts and dead bolts are engaged into strike and hardware is functioning.
3. Report findings, in writing, to Contracting Officer indicating that all hardware is installed and functioning properly. Include recommendations outlining corrective actions for improperly functioning hardware if required.
3.5 SCHEDULE OF FINISH HARDWARE
A. MANUFACTURER LIST
Code Name
AB ABH Manufacturing
BE Best Access Systems
BE BEST
BY By Others
HS Hes
LM Lockmasters, Inc.
PE Pemko
PR Precision
SD Security Door Controls
08 71 00 15 DOOR HARDWARE
ST Stanley
TR Trimco
3.6 OPTION LIST
Code Description
CD CYLINDER DOGGING
FL Fire Exit Hardware
LD Less Dogging
SN Sex Nuts (Pkg. of 4)
TS TOUCHBAR MONITORING SWITCH
B4E BEVELED 4 EDGES
ELR ELECTRIC LATCH RETRACTION
N-GL "N" THRU BUTTON
R703 STRAIGHT CYLINDER RING - 3/16"
EPT Prep EPT Prep (full mortise)
P45-180D Drop Plate for Narrow Top Rail
CSK COUNTER SINKING
(#) Electronic Hardware – See Riser Drawings
3.7 FINISH LIST
Code Description
628 Aluminum
626 Satin Chromium Plated
628 Satin Aluminum, Clear Anodized
630 Satin Stainless Steel
689 Aluminum Painted
652 Chromium Plated, Dull
630 Stainless Steel, Dull
08 71 00 16 DOOR HARDWARE
END OF SECTION 08 71 00
| PART 1 - GENERAL |
| 1.1 SUMMARY |
| A. Section Includes: Finish Hardware for door openings, except as otherwise specified herein. |
| 1. Door hardware for aluminum doors. |
| 2. Door hardware for other doors indicated. |
| 3. Keyed cylinders as indicated. |
| B. Related Sections: |
| 1. Division 6: Rough Carpentry. |
| 2. Division 8: Aluminum Doors and Frames. |
| 3. Division 26: Electrical. |
| 4. Division 28: Electronic Security. |
| C. References: Comply with applicable requirements of the following standards. Where these standards conflict with other specific requirements, the most restrictive shall govern. |
| 1. Builders Hardware Manufacturing Association (BHMA). |
| 2. NFPA 101 Life Safety Code. |
| 3. NFPA 80 Fire Doors and Windows. |
| 4. ANSI-A156.xx Various Performance Standards for Finish Hardware. |
| 5. UL10C Positive Pressure Fire Test of Door Assemblies. |
| 6. ANSI-A117.1 Accessible and Usable Buildings and Facilities. |
| 7. DHI /ANSI A115.IG Installation Guide for Doors and Hardware. |
| D. Intent of Hardware Groups: |
| 1. Should items of hardware not definitely specified be required for completion of the Work, furnish such items of type and quality comparable to adjacent hardware and appropriate for service required. |
| 2. Where items of hardware aren’t definitely or correctly specified, are required for completion of the Work, a written statement of such omission, error, or other discrepancy to the Contracting Officer, prior to date specified for receipt of bids for... |
| E. N/A |
| F. Alternates: Refer to Division 1 for Alternates and procedures. |
| 1.2 SUBSTITUTIONS |
| A. Comply with Division 1. |
| 1.3 SUBMITTALS |
| A. Comply with Division 1. |
| B. Special Submittal Requirements: Combine submittals of this Section with Sections listed below to ensure the "design intent" of the system/assembly is understood and can be reviewed together. |
| C. Product Data: Manufacturer's specifications and technical data including the following: |
| 1. Detailed specification of construction and fabrication. |
| 2. Manufacturer's installation instructions. |
| 3. Wiring diagrams for each electric product specified. Coordinate voltage with electrical before submitting. |
| 4. Submit 6 copies of catalog cuts with hardware schedule. |
| D. Shop Drawings - Hardware Schedule: Submit six complete reproducible copy of detailed hardware schedule in a vertical format. |
| 1. List groups and suffixes in proper sequence. |
| 2. Completely describe door and list architectural door number. |
| 3. Manufacturer, product name, and catalog number. |
| 4. Function, type, and style. |
| 5. Size and finish of each item. |
| 6. Mounting heights. |
| 7. Explanation of abbreviations and symbols used within schedule. |
| 8. Detailed wiring diagrams, specially developed for each opening, indicating all electric hardware, security equipment and access control equipment, and door and frame rough-ins required for specific opening. |
| E. Templates: Submit templates and "reviewed Hardware Schedule" to door and frame supplier and others as applicable to enable proper and accurate sizing and locations of cutouts and reinforcing. |
| 1. Templates, wiring diagrams and "reviewed Hardware Schedule" of electrical terms to electrical for coordination and verification of voltages and locations. |
| F. Samples: |
| 1. One sample of Lever and Rose/Escutcheon design, (pair). |
| 2. Three samples of metal finishes. |
| G. Contract Closeout Submittals: Comply with Division 1 including specific requirements indicated. |
| 1. Operating and maintenance manuals: Submit three sets containing the following. |
| a. Complete information in care, maintenance, and adjustment, and data on repair and replacement parts, and information on preservation of finishes. |
| b. Catalog pages for each product. |
| c. Name, address, and phone number of local representative for each manufacturer. |
| d. Parts list for each product. |
| e. Copy of final hardware schedule, edited to reflect, "As installed". |
| f. Copy of final keying schedule. |
| g. As installed “Wiring Diagrams” for each piece of hardware connected to power, both low voltage and 110 volts. |
| h. One set of special tools required for maintenance and adjustment of hardware, including changing of cylinders. |
| 1.4 QUALITY ASSURANCE |
| A. Comply with Division 1. |
| 1. Statement of qualification for distributor and installers. |
| 2. Statement of compliance with regulatory requirements and single source responsibility. |
| 3. Distributor's Qualifications: Firm with 3 years experience in the distribution of commercial hardware. |
| a. Distributor to employ full time Architectural Hardware Consultants (AHC) for the purpose of scheduling and coordinating hardware and establishing keying schedule. |
| b. Hardware Schedule shall be prepared and signed by an AHC. |
| 4. Installer's Qualifications: Firm with 3 years experienced in installation of similar hardware to that required for this Project, including specific requirements indicated. |
| 5. Regulatory Label Requirements: Provide testing agency label or stamp on hardware for labeled openings. |
| a. Provide UL listed hardware for labeled and 20-minute openings in conformance with requirements for class of opening scheduled. |
| b. Underwriters Laboratories requirements have precedence over this specification where conflict exists. |
6. Single Source Responsibility: Except where specified in hardware schedule, furnish products of only one manufacturer for each type of hardware.
B. Review Project for extent of finish hardware required to complete the Work. Where there is a conflict between these Specifications and the existing hardware, notify the Contracting Officer in writing and furnish hardware in compliance with the Spec...
| 1.5 DELIVERY, STORAGE, AND HANDLING |
| A. Packing and Shipping: Comply with Division 1. |
| 1. Deliver products in original unopened packaging with legible manufacturer's identification. |
| 2. Package hardware to prevent damage during transit and storage. |
| 3. Mark hardware to correspond with "reviewed hardware schedule". |
| 4. Deliver hardware to door and frame manufacturer upon request. |
B. Storage and Protection: Comply with manufacturer's recommendations.
| 1.6 PROJECT CONDITIONS |
| A. Coordinate hardware with other work. Furnish hardware items of proper design for use on doors and frames of the thickness, profile, swing, security and similar requirements indicated, as necessary for the proper installation and function, regardles... |
| B. Door and frame prep: Before hardware installation, verify that all doors and frames are properly prepared to receive the specified hardware. Hollow metal frames shall be prepared for ANSI strike plates per A115.1-2 (4-7/8" high), hinge preps will ... |
| 1.7 WARRANTY |
| A. Refer to Conditions of the Contract. |
| B. Manufacturer’s Warranty: |
| 1. Closers: 10 years. |
| 2. Exit Devices: 3 years. |
| 3. Locksets and Cylinders: 3 years. |
| 4. All other Hardware: 2 years. |
| 1.8 OPERATING AND MAINTENANCE |
| A. Instruct Government’s personnel in operation and maintenance of hardware units. |
| 1.9 MAINTENANCE |
| A. Extra Service Materials: Deliver to Contracting Officer extra materials from same production run as products installed. Package products with protective covering and identify with descriptive labels. Comply with Division 1 Closeout Submittals Section. |
| 1. Special Tools: Provide special wrenches and tools applicable to each different or special hardware component. |
| 2. Maintenance Tools: Provide maintenance tools and accessories supplied by hardware component manufacturer. |
| 3. Delivery, Storage and Protection: Comply with requirements for delivery, storage and protection of extra service materials. |
B. Maintenance Service: Submit maintenance service agreement for electronic products installed.
| PART 2 - PRODUCTS |
| 2.1 MANUFACTURERS |
| A. The following manufacturers are approved subject to compliance with requirements of the Contract Documents. Approval of manufacturers other than those listed shall be in accordance with Division 1. |
| DOOR HARDWARE |
| Description Manufacturer Model / Series Finish |
| Hanging Devices |
| Continuous Hinge Stanley 661HD/662HD (Geared Type) 628 |
| Alternate Hager/Roton 780-112HD/780-224HD 628 |
| Description Manufacturer Model / Series Finish |
| Alternate No Substitute |
| Alternate No Substitution |
| Alternate No Substitution |
| Keying Best Existing "Standard" lnterchangble Core 626 |
| Alternate No Substitution |
| Manual Flush Bolts Rockwood 555 (Manual) (metal doors) 626 |
| Door Stop Rockwood 403/409 Wall Stop (Interior) 626 |
| Description Manufacturer Model / Series Finish |
| Description Manufacturer Model / Series _______Finish |
| MATERIALS |
| B. Hinges: Shall be Five Knuckle Ball bearing hinges. |
| 1. Template screw hole locations. |
| 2. Bearings are to be fully hardened. |
| 3. Bearing shell is to be consistent shape with barrel. |
| 4. Minimum of two permanently lubricated non-detachable bearings on standard weight hinge and four permanently lubricated bearing on heavy weight hinges. |
| 5. Equip with easily seated, non-rising pins. |
| 6. Non-removable pin screws shall be slotted stainless steel screws. |
| 7. Hinges shall be full polished, front, back and barrel. |
| 8. Hinge pin is to be fully plated. |
| 9. Bearing assembly is to be installed after plating. |
| 10. Sufficient size to allow 180-deg swing of door. |
| 11. Furnish five knuckles with flush ball bearings. |
| 12. Provide hinge type as listed in schedule. |
| 13. Furnish three hinges per leaf to 7-foot 6-inch height. Add one for each additional 30 inches in height or fraction thereof. |
| 14. Tested and approved by BHMA for all applicable ANSI Standards for type, size, function and finish. |
| 15. UL10C listed for Fire. |
| C. Geared Continuous Hinges: |
| 1. Tested and approved by BHMA for ANSI A 156.26-1996 Grade 1. |
| 2. Anti-spinning through fastener. |
| 3. UL10C listed for 3-hour fire rating. |
| 4. Non-handed. |
| 5. Lifetime warranty. |
| 6. Provide fire pins for 3-hour fire ratings. |
| 7. Sufficient size to permit door to swing 180 deg. |
| D. Mortise Type Locks and Latches: |
| 1. Tested and approved by BHMA for ANSI A 156.13, Series 1000, Operational Grade 1, Extra-Heavy Duty, Security Grade 2 and be UL10C. |
| 2. Fit ANSI A 115.1 door preparation. |
| 3. Functions and design as indicated in the hardware groups. |
| 4. Solid, one-piece, 3/4-inch (19-mm) throw, anti-friction latchbolt made of self-lubricating stainless steel. |
| 5. Deadbolt functions shall have 1 inch (25 mm) throw bolt made of hardened stainless steel. |
| 6. Latchbolt and deadbolt are to extend into the case a minimum of 3/8 inch (9.5 mm) when fully extended. |
| 7. Auxiliary deadlatch to be made of one piece stainless steel, permanently lubricated. |
| 8. Provide sufficient curved strike lip to protect door trim. |
| 9. Lever handles must be of forged or cast brass, bronze or stainless steel construction and conform to ANSI A 117.1. Levers that contain a hollow cavity are not acceptable. |
| 10. Lock shall have self-aligning, thru-bolted trim. |
| 11. Levers to operate a roller bearing spindle hub mechanism. |
| 12. Mortise cylinders of lock shall have a concealed internal setscrew for securing the cylinder to the lockset. The internal setscrew will be accessible only by removing the core, with the control key, from the cylinder body. |
| 13. Spindle to be designed to prevent forced entry from attacking of lever. |
| 14. Provide locksets with 7-pin removable and interchangeable core cylinders. |
| 15. Each lever to have independent spring mechanism controlling it. |
| 16. Core face must be the same finish as the lockset. |
| E. Exit Devices Shall: |
| 1. Tested and approved by BHMA for ANSI 156.3, Grade 1. |
| 2. Provide a deadlocking latchbolt. |
| 3. Non-fire rated exit devices shall have cylinder dogging. |
| 4. Touchpad shall be “T” style. |
| 5. Exposed components shall be of architectural metals and finishes. |
| 6. Lever design shall match lockset lever design. |
| 7. Provide strikes as required by application. |
| 8. Fire exit devices to be listed for UL10C. |
| 9. UL listed for Accident Hazard. |
| 10. Provide vandal resistant or breakaway trim. |
| 11. Aluminum vertical rod assemblies are acceptable only when provide with the manufacturers optional top and bottom stainless steel rod guard protectors. |
| F. Cylinders: |
| 1. Provide the necessary cylinder housings, collars, rings and springs as recommended by the manufacturer for proper installation. |
| 2. Provide the proper cylinder cams or tail piece as required to operate all locksets and other keyed hardware items listed in the hardware sets. |
| 3. Coordinate and provide as required for related sections. |
| G. Door Closers Shall: |
| 1. Tested and approved by BHMA for ANSI 156.4, Grade 1. |
| 2. UL10C certified. |
| 3. Closer shall have extra-duty arms and knuckles. |
| 4. Conform to ANSI 117.1. |
| 5. Maximum 2-7/16-inch case projection with non-ferrous cover. |
| 6. Separate adjusting valves for closing and latching speed, and backcheck. |
| 7. Provide adapter plates, shim spacers and blade stop spacers as required by frame and door conditions. |
| 8. Full rack and pinion type closer with 1-1/2-inch minimum bore. |
| 9. Mount closers on non-public side of door, unless otherwise noted in specification. |
| 10. Closers shall be non-handed, non-sized and multi-sized. |
| H. Door Stops: Provide a dome floor or wall stop for every opening as listed in the hardware sets. |
| 1. Wall stop and floor stop shall be wrought bronze, brass or stainless steel. |
| 2. Provide fastener suitable for wall construction. |
| 3. Coordinate reinforcement of walls where wall stop is specified. |
| 4. Provide dome stops where wall stops are not practical. Provide spacers or carpet riser for floor conditions encountered. |
| I. Over Head Stops: Provide a Surface mounted or concealed overhead when a floor or wall stop cannot be used or when listed in the hardware set. |
| 1. Concealed overhead stops shall be heavy duty bronze or stainless steel. |
| 2. Surface overhead stops shall be heavy duty bronze or stainless steel. |
| J. Push Plates: Provide with four beveled edges ANSI J301, 0.050 thickness, size as indicated in hardware set. Furnish oval-head countersunk screws to match finish. |
| K. Pulls with Plates: Provide with four beveled edges ANSI J301, 0.050 thickness Plate s with ANSI J401 Pull as listed in hardware set. Provide proper fasteners for door construction. |
| L. Push Pull Bars: Provide ANSI J504, 0.1-inch diameter pull and push bar model and series as listed in hardware set. Provide proper fasteners for door construction. |
| M. Kickplates: Provide with four beveled edges ANSI J102, 10 inches high by width less 2 inches on single doors and 1 inch on pairs of doors. Furnish oval-head countersunk screws to match finish. |
| N. Mop Plates: Provide with four beveled edges ANSI J103, 4 inches high by width less 1 inch on single doors and 1 inch on pairs of doors. Furnish oval-head countersunk screws to match finish. |
| O. Door Bolts: Flush bolts for wood or metal doors. |
| 1. Provide a set of Automatic bolts ANSI/BHMA 156.3 Type 25 for hollow metal label doors. |
| 2. Provide a set of Automatic bolts ANSI/BHMA 156.3 Type 27 at wood label doors. |
| 3. Manual flush bolts ANSI/BHMA 156.16 at openings where allowed local authority. |
| 4. Provide Dust Proof Strike ANSI/BHMA 156.16 at doors with flush bolts without thresholds. |
| P. Coordinator and Brackets: Provide a surface mounted coordinator when automatic bolts are used in the hardware set. |
| 1. Coordinator shall comply with ANSI/BHMA A1156.3 Type 21A full width of the opening. |
| 2. Provide mounting brackets for soffit applied hardware. |
| 3. Provide hardware preparation (cutouts) for latches as necessary. |
| Q. Power Supply (14): Provide power supply for (ELR) Electric Latch Retraction exit devices |
| 1. Motherboard will accept up to four plug-in Control Modules. Provide the appropriate necessary control module to operate the number of ELR exit devices used at each opening. The Control Module shall include a Time delay Feature, variable (0 to 4 min... |
| 2. UL Listed for Class II output |
| 3. Include circuit breakers for protection of motherboard, |
| 4. 115- or 230-Volt user selectable switch, with AC input equals 115-volt at 1 amp. |
| 5. Control module shall include fire alarm terminal and auxiliary contacts for remote signaling. |
| 6. Optional card for Battery Backup (BT) power tap module to operate a card reader or when ELR devices require battery backup (lead acid batteries are not included and is to be furnished by others). |
| 7. Precision ELR150 Series with the required modules. |
| R. Power Transfer (7): Power transfer device shall be a steel housing and flexible tube. Secure and inconspicuous channel is to bring power from the frame to the door. |
| 1. Precision EPT-5. |
| 2. Tube shall accept up to 5/16-inch wire bundle and accommodate a door swing of 120 deg. |
| 3. Wires as required by others. |
| S. Electric Door Strike: ANSI/BHMA 156.31, Grade 1. and listed for Burglary Protection ANSI/UL1034 Grade 1. |
| 1. For General use provide fail-secure electric strike and with fire-rated device. |
| 2. Listed UL10C-1997 fire door assemblies. |
| 3. Latchbolt monitor switch option when specified in hardware sets. |
| 4. Provide the electric strike in the appropriate model that will accept a 5/8-inch or 3/4-inch latchbolt. |
| T. Door Position Switch: Provide door position switch for door status monitoring as indicated in hardware sets. |
| 1. At all fired rated doors the door and frame hardware preparation will be provided by the door and frame manufacturer or by an authorized label service agent. |
| U. Seals: All seals shall be finished to match adjacent frame color. Seals shall be furnished as listed in schedule. Material shall be UL listed for labeled openings. |
| V. Weatherstripping: Provide at head and jambs only those units where resilient or flexible seal strip is easily replaceable. Where bar-type weatherstrip is used with parallel arm mounted closers install weatherstrip first. |
| 1. Weatherstrip shall be resilient seal of (neoprene, polyurethane, vinyl, pile, nylon brush, silicone). |
| 2. UL10C positive pressure rated seal set when required. |
| W. Door Bottoms/Sweeps: Surface mounted or concealed door bottom where listed in the hardware sets. |
| 1. Door seal shall be resilient seal of (neoprene, polyurethane, nylon brush, silicone). |
| 2. UL10C positive pressure rated seal set when required. |
| X. Thresholds: Thresholds shall be aluminum beveled type with maximum height of 1/2 inch for conformance with ADA requirements. Furnish as specified and per details. Provide fasteners and screws suitable for floor conditions. |
| Y. Key Control: Provide one wall mounted key cabinet complete with hooks, index and tags. Hook quantity shall be 50 percent over lock quantity. |
| Z. Silencers: Furnish silencers on all interior frames, three for single doors, two for pairs. Omit where any type of seals occur. |
| 2.2 FINISH |
| A. Designations Used in Schedule of Finish Hardware: 3.5, and elsewhere to indicate hardware finishes are those listed in ANSI/BHMA A 156.18 including coordination with traditional U.S. finishes shown by certain manufacturers for their products. |
| B. Powder coat door closers to match other hardware, unless otherwise noted. |
| C. Aluminum items shall be finished to match predominant adjacent material. Seals to coordinate with frame color. |
| 2.3 KEYS AND KEYING |
| A. Provide keyed brass construction cores and keys during the construction period. Construction control and operating keys and core shall not be part of the Government's permanent keying system or furnished in the same keyway (or key section) as the G... |
| B. Cylinders, Removable and Interchangeable Core System: Best Standard 7-pin. |
| C. Permanent Keys and Cores: Stamped with the applicable key mark for identification. These visual key control marks or codes will not include the actual key cuts. Permanent keys will also be stamped "Do Not Duplicate." |
| D. Transmit Grand Masterkeys, Masterkeys, and other security keys to Contracting Officer by registered mail, return receipt requested. |
| E. Furnish keys in the following quantities: |
| 1. 1 each Grand Masterkeys. |
| 2. 2 each Control keys. |
| 3. 4 each Masterkeys. |
| 4. 3 each Change keys each keyed core. |
| 5. 15 each Construction Masterkeys. |
| 6. 2 each Construction Control keys. |
F. The Government will install permanent cores and return the construction cores to the Hardware Supplier. Construction cores and keys remain the property of the Hardware Supplier.
| PART 3 - EXECUTION |
| 3.1 EXAMINATION |
| A. Verification of conditions: Examine doors, frames, related items and conditions under which Work is to be performed and identify conditions detrimental to proper and or timely completion. |
| 1. Do not proceed until unsatisfactory conditions have been corrected. |
| 3.2 HARDWARE LOCATIONS |
| A. Mount hardware units at heights indicated in the following publications except as specifically indicated or required to comply with the governing regulations. |
| 1. Recommended Locations for Builder’s Hardware for Standard Steel Doors and Frames, by the Door and Hardware Institute (DHI). |
| 2. Recommended locations for Architectural Hardware for flush wood doors (DHI). |
| 3. WDMA Industry Standard I.S.-1A-04, Industry Standard for Architectural wood flush doors. |
| 3.3 INSTALLATION |
| A. Install each hardware item per manufacturer's instructions and recommendations. Do not install surface mounted items until finishes have been completed on the substrate. Set units level, plumb and true to line and location. Adjust and reinforce the... |
| B. Conform to local governing agency security ordinance. |
| C. Install Conforming to ICC/ANSI A 117.1 Accessible and Usable Building and Facilities. |
| D. Installed hardware using the manufacturers fasteners provided. Drill and tap all screw holes located in metallic materials. Do not use “Riv-Nuts” or similar products. |
| 3.4 FIELD QUALITY CONTROL AND FINAL ADJUSTMENT |
| A. Contractor/Installers, Field Services: After installation is complete, Contractor shall inspect the completed door openings on site to verify installation of hardware is complete and properly adjusted, in accordance with both the Contract Documents... |
| 1. Check and adjust closers to ensure proper operation. |
| 2. Check latchset, lockset, and exit devices are properly installed and adjusted to ensure proper operation. |
| a. Verify levers are free from binding. |
| b. Ensure latchbolts and dead bolts are engaged into strike and hardware is functioning. |
3. Report findings, in writing, to Contracting Officer indicating that all hardware is installed and functioning properly. Include recommendations outlining corrective actions for improperly functioning hardware if required.
| 3.5 SCHEDULE OF FINISH HARDWARE |