055000_FL.pdf

PDF 67 KB Posted

Attached to
Install Security Door- BLDG 128 Federal contract opportunity
Solicitation number
W912JB-18-R-5010
Issued by
Department of the Army Michigan Army National Guard

About this file

Specs 055000

View the file

Other files for this federal contract opportunity

Other files attached to Install Security Door- BLDG 128, newest first.
File Type Posted
site_visit_attendance_12807-17-2018-140922.pdf PDF
Site_Visit_Minutes_128_door.pdf PDF
amendment_2.pdf PDF
NAICS_amendment.pdf PDF
092216_FL.pdf PDF
Vetting_Access_Request_List.pdf PDF
084113.pdf PDF
172013_-_Install_Security_Dr_B-128_Sheet_1_dwg.pdf PDF
092900_FL.pdf PDF
Final_Solicitation.pdf PDF
088000.pdf PDF
099123_FL.pdf PDF
087100_FL.pdf PDF
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SELFRIDGE ANGB, MICHIGAN

05 50 00 1 METAL FABRICATIONS

SECTION 05 50 00 - METAL FABRICATIONS

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

1.2 SUMMARY

A. Section Includes:

1. Steel framing and supports for applications where framing and supports are not specified in other Sections.

2. Shelf angles.

3. Metal ladders.

4. Miscellaneous steel trim including steel angle corner guards, steel edgings.

5. Metal bollards.

6. Loose bearing and leveling plates for applications where they are not specified in other

Sections.

B. Products furnished, but not installed, under this Section:

1. Loose steel lintels.

2. Anchor bolts, steel pipe sleeves, and wedge-type inserts indicated to be cast into concrete or built into unit masonry.

3. Steel weld plates and angles for casting into concrete for applications where they are not specified in other Sections.

C. Related Sections:

1. Section 03 30 00, Cast-in-Place Concrete, for installing anchor bolts, steel pipe sleeves, slotted-channel inserts, wedge-type inserts, and other items cast into concrete.

2. Section 04 20 00, Unit Masonry, for installing loose lintels, anchor bolts, and other items built into unit masonry.

3. Section 05 12 00, Structural Steel Framing.

1.3 PERFORMANCE REQUIREMENTS

A. Delegated Design: Design ladders, including comprehensive engineering analysis by a qualified professional engineer, using performance requirements and design criteria indicated.

05 50 00 2 METAL FABRICATIONS

B. Thermal Movements: Allow for thermal movements from ambient and surface temperature changes acting on exterior metal fabrications by preventing buckling, opening of joints, overstressing of components, failure of connections, and other detrimental effects.

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

1.4 SUBMITTALS

A. Product Data: For the following:

1. Grout.

B. Submittals:

1. Building Submittal Requirements:

1) Product Data and Cut Sheets: Data and cut sheets shall be submitted for each product and accessory specified. Product data and cut sheets shall be marked with the Contractor’s stamp as confirmation that the submitted products are the products installed on the project.

C. Shop Drawings: Show fabrication and installation details for metal fabrications.

1. Include plans, elevations, sections, and details of metal fabrications and their connections. Show anchorage and accessory items.

D. Delegated-Design Submittal: For installed products indicated to comply with performance requirements and design criteria, including analysis data signed and sealed by the qualified professional engineer responsible for their preparation.

E. Qualification Data: For qualified professional engineer.

F. Welding certificates.

1.5 QUALITY ASSURANCE

A. Welding Qualifications: Qualify procedures and personnel according to AWS D1.1/D1.1M, "Structural Welding Code - Steel."

1.6 PROJECT CONDITIONS

A. Field Measurements: Verify actual locations of walls and other construction contiguous with metal fabrications by field measurements before fabrication.

05 50 00 3 METAL FABRICATIONS

1.7 COORDINATION

A. Coordinate selection of shop primers with topcoats to be applied over them. Comply with paint and coating manufacturers' written recommendations to ensure that shop primers and topcoats are compatible with one another.

B. Coordinate installation of anchorages and items embedded into concrete and masonry. Furnish setting drawings, templates, and directions for installing anchorages, including sleeves, concrete inserts, anchor bolts, and items with integral anchors, that are to be embedded in concrete or masonry. Deliver such items to Project site in time for installation.

PART 2 - PRODUCTS

2.1 METALS, GENERAL

A. Metal Surfaces, General: Provide materials with smooth, flat surfaces unless otherwise indicated. For metal fabrications exposed to view in the completed Work, provide materials without seam marks, roller marks, rolled trade names, or blemishes.

2.2 FERROUS METALS

A. Recycled Content of Steel Products: Provide products with average recycled content of steel products so postconsumer recycled content plus one-half of preconsumer recycled content is not less than 25 percent.

B. Steel Plates, Shapes, and Bars: ASTM A 36/A 36M.

C. Steel Tubing: ASTM A 500, Grade B structural tubing.

D. Steel Pipe: ASTM A 53/A 53M, Type E or S, Grade B.

2.3 FASTENERS

A. General: Unless otherwise indicated, provide Type 304 stainless-steel fasteners for exterior use and zinc-plated fasteners with coating complying with ASTM B 633 or ASTM F 1941 (ASTM F 1941M), Class Fe/Zn 5, at exterior walls. Select fasteners for type, grade, and class required.

B. Steel Bolts and Nuts: Regular hexagon-head bolts, ASTM A 307, Grade A (ASTM F 568M, Property Class 4.6); with hex nuts, ASTM A 563 (ASTM A 563M); and, where indicated, flat washers.

C. Stainless-Steel Bolts and Nuts: Regular hexagon-head annealed stainless-steel bolts, ASTM F 593 (ASTM F 738M); with hex nuts, ASTM F 594 (ASTM F 836M); and, where indicated, flat washers; Alloy Group 1 (A1).

05 50 00 4 METAL FABRICATIONS

D. Anchor Bolts: ASTM F 1554, Grade 36, of dimensions indicated; with nuts, ASTM A 563;

and, where indicated, flat washers.

1. Hot-dip galvanize or provide mechanically deposited, zinc coating where item being fastened is indicated to be galvanized.

E. Plain Washers: Round, ASME B 18.22.1 (ASME B 18.22M).

F. Post-Installed Anchors: Wedge anchors, screw anchors, and adhesive anchors as indicated in the Drawings.

1. General:

a. Material for Interior Locations: Carbon-steel components zinc plated to comply with ASTM B 633 or ASTM F 1941 (ASTM F 1941M), Class Fe/Zn 5, unless otherwise indicated.

b. Material for Exterior Locations and Where Stainless Steel is Indicated: Alloy Group 1 (A1) stainless-steel bolts, ASTM F 593 (ASTM F 738M), and nuts, ASTM F 594 (ASTM F 836M).

c. Current evaluation and acceptance report by ICC or other similar code organization.

2. Wedge Anchors:

a. Manufacturers and Products:

1) ITW Ramset/Red Head, Addison, IL; Trubolt Wedge Anchor.

2) Hilti, Inc., Tulsa, OK; Kwik-Bolt-3 (KB-3) or Kwik-Bolt TZ Anchor.

3) Simpson Strong-Tie Co., Inc., Pleasanton, CA; Wedge-All or Strong-Bolt

Wedge Anchor.

4) Or approved equal.

3. Adhesive Anchors:

a. Threaded Rod:

1) ASTM F593 stainless steel threaded rod, diameter as shown on Drawings.

2) Length as required, to provide minimum depth of embedment.

3) Clean and free of grease, oil, or other deleterious material.

4) For hollow-unit masonry, provide galvanized or stainless steel wire cloth screen tube to fit threaded rod.

b. Adhesive:

1) Adhesives shall pass the ICC-ES AC 308 test for long-term creep.

2) Two-component, designed to be used in adverse freeze/thaw environments, with gray color after mixing.

3) Cure Temperature, Pot Life, and Workability: Compatible for intended use and environmental conditions.

4) Nonsag, with selected viscosity base on installation temperature and overhead application where applicable.

05 50 00 5 METAL FABRICATIONS

c. Packaging and Storage:

1) Disposable, self-contained cartridge system capable of dispensing both components in the proper mixing ratio and fitting into a manually or pneumatically operated caulking gun.

2) Store adhesive cartridges on pallets or shelving in covered storage area, in accordance with manufacturer’s written instructions.

3) Cartridge Markings: Include manufacturer’s name, product name, material type, batch or serial number, and adhesive expiration date.

4) Dispose of cartridges if shelf life has expired.

d. Manufacturers and Products:

1) No “fast-set” epoxies shall be used.

2) Hilti, Inc., Tulsa, OK; HIT-HY-150-MAX Epoxy Adhesive Anchor System or HIT-RE-500SD Adhesive Anchors.

3) Simpson Strong-Tie Co., Inc., Pleasanton, CA; SET-XP Epoxy-Tie

Adhesive.

4) Or approved equal.

4. Screw Anchors:

a. Manufacturers and Products:

1) Simpson Strong Tie Co., Inc., Pleasanton, CA; Titen HD Screw Anchor.

2) Or approved equal.

2.4 MISCELLANEOUS MATERIALS

A. Shop Primers: Provide primers that comply with Division 09 painting Sections.

B. Nonshrink, Nonmetallic Grout: Factory-packaged, nonstaining, noncorrosive, nongaseous grout complying with ASTM C 1107. Provide grout specifically recommended by manufacturer for interior and exterior applications.

2.5 FABRICATION, GENERAL

A. Shop Assembly: Preassemble items in the shop to greatest extent possible. Disassemble units only as necessary for shipping and handling limitations. Use connections that maintain structural value of joined pieces. Clearly mark units for reassembly and coordinated installation.

B. Cut, drill, and punch metals cleanly and accurately. Remove burrs and ease edges to a radius of approximately 1/32 inch (1 mm) unless otherwise indicated. Remove sharp or rough areas on exposed surfaces.

C. Form bent-metal corners to smallest radius possible without causing grain separation or otherwise impairing work.

05 50 00 6 METAL FABRICATIONS

D. Form exposed work with accurate angles and surfaces and straight edges.

E. Weld corners and seams continuously to comply with the following:

1. Use materials and methods that minimize distortion and develop strength and corrosion resistance of base metals.

2. Obtain fusion without undercut or overlap.

3. Remove welding flux immediately.

4. At exposed connections, finish exposed welds and surfaces smooth and blended so no roughness shows after finishing and contour of welded surface matches that of adjacent surface.

F. Form exposed connections with hairline joints, flush and smooth, using concealed fasteners or welds where possible. Where exposed fasteners are required, use Phillips flat-head (countersunk) fasteners unless otherwise indicated. Locate joints where least conspicuous.

G. Fabricate seams and other connections that will be exposed to weather in a manner to exclude water. Provide weep holes where water may accumulate.

H. Cut, reinforce, drill, and tap metal fabrications as indicated to receive finish hardware, screws, and similar items.

I. Provide for anchorage of type indicated; coordinate with supporting structure. Space anchoring devices to secure metal fabrications rigidly in place and to support indicated loads.

1. Where units are indicated to be cast into concrete or built into masonry, equip with integrally welded steel strap anchors, 1/8 by 1-1/2 inches (3.2 by 38 mm), with a minimum 6-inch (150-mm) embedment and 2-inch (50-mm) hook, not less than 8 inches (200 mm) from ends and corners of units and 24 inches (600 mm) o.c., unless otherwise indicated.

2.6 MISCELLANEOUS FRAMING AND SUPPORTS

A. General: Provide steel framing and supports not specified in other Sections as needed to complete the Work.

B. Fabricate units from steel shapes, plates, and bars of welded construction unless otherwise indicated. Fabricate to sizes, shapes, and profiles indicated and as necessary to receive adjacent construction.

1. Fabricate units from slotted channel framing where indicated.

2. Furnish inserts for units installed after concrete is placed.

C. Prime miscellaneous framing and supports with Division 09 painting Sections.

2.7 METAL LADDERS

A. General: Comply with ANSI A 14.3 and OSHA requirements unless otherwise indicated.

05 50 00 7 METAL FABRICATIONS

B. Steel Ladders:

1. Space siderails 18 inches (457 mm) apart unless otherwise indicated.

2. Siderails: Continuous, 3/8-by-2-1/2-inch (9.5-by-64-mm) steel flat bars, with eased edges.

3. Rungs: 1-inch- (25-mm-) diameter steel bars.

4. Fit rungs in centerline of siderails; plug-weld and grind smooth on outer rail faces.

5. Provide nonslip surfaces on top of each rung by coating with abrasive material metallically bonded to rung.

6. Support each ladder at top and bottom and not more than 60 inches (1500 mm) o.c. with welded or bolted steel brackets.

7. Prime interior ladders, including brackets and fasteners, with primer specified in

Division 09 painting Sections.

8. Exterior ladders shall be hot dip galvanized after fabrication, then primed, as specified in

Division 09 painting Sections.

2.8 MISCELLANEOUS STEEL TRIM

A. Unless otherwise indicated, fabricate units from steel shapes, plates, and bars of profiles shown with continuously welded joints and smooth exposed edges. Miter corners and use concealed field splices where possible.

B. Provide cutouts, fittings, and anchorages as needed to coordinate assembly and installation with other work.

1. Provide with integrally welded steel strap anchors for embedding in concrete or masonry construction.

C. Prime miscellaneous steel trim with primer specified in Division 09 painting Sections.

2.9 METAL BOLLARDS

A. Fabricate metal bollards from Schedule 40 steel pipe.

1. Where bollards are indicated to receive controls for door operators, provide necessary cutouts for controls and holes for wire.

2. Where bollards are indicated to receive light fixtures, provide necessary cutouts for fixtures and holes for wire.

B. Prime bollards with primer specified in Division 09 painting Sections.

2.10 LOOSE STEEL LINTELS

A. Fabricate loose steel lintels from steel angles and shapes of size indicated for openings and recesses in masonry walls and partitions at locations indicated. Fabricate in single lengths for each opening unless otherwise indicated. Weld adjoining members together to form a single unit where indicated.

05 50 00 8 METAL FABRICATIONS

B. Galvanize loose steel lintels located in exterior walls.

2.11 STEEL WELD PLATES AND ANGLES

A. Provide steel weld plates and angles not specified in other Sections, for items supported from concrete construction as needed to complete the Work. Provide each unit with no fewer than two integrally welded steel strap anchors for embedding in concrete.

2.12 FINISHES, GENERAL

A. Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations for applying and designating finishes.

B. Finish metal fabrications after assembly.

C. Finish exposed surfaces to remove tool and die marks and stretch lines, and to blend into surrounding surface.

2.13 STEEL AND IRON FINISHES

A. Galvanizing: Hot-dip galvanize items as indicated to comply with ASTM A 153/A 153M for steel and iron hardware and with ASTM A 123/A 123M for other steel and iron products.

1. Do not quench or apply post galvanizing treatments that might interfere with paint adhesion.

B. Shop prime iron and steel items not indicated to be galvanized unless they are to be embedded in concrete, or masonry, or unless otherwise indicated.

1. Shop prime with primers specified in Division 09 painting Sections.

C. Preparation for Shop Priming: Prepare surfaces to comply with SSPC-SP 3, "Power Tool Cleaning."

D. Shop Priming: Apply shop primer to comply with SSPC-PA 1, "Paint Application Specification No. 1: Shop, Field, and Maintenance Painting of Steel," for shop painting.

1. Stripe paint corners, crevices, bolts, welds, and sharp edges.

PART 3 - EXECUTION

3.1 INSTALLATION, GENERAL

A. Cutting, Fitting, and Placement: Perform cutting, drilling, and fitting required for installing metal fabrications. Set metal fabrications accurately in location, alignment, and elevation; with edges and surfaces level, plumb, true, and free of rack; and measured from established lines and levels.

05 50 00 9 METAL FABRICATIONS

B. Fit exposed connections accurately together to form hairline joints. Weld connections that are not to be left as exposed joints but cannot be shop welded because of shipping size limitations.

Do not weld, cut, or abrade surfaces of exterior units that have been hot-dip galvanized after fabrication and are for bolted or screwed field connections.

C. Field Welding: Comply with the following requirements:

1. Use materials and methods that minimize distortion and develop strength and corrosion resistance of base metals.

2. Obtain fusion without undercut or overlap.

3. Remove welding flux immediately.

4. At exposed connections, finish exposed welds and surfaces smooth and blended so no roughness shows after finishing and contour of welded surface matches that of adjacent surface.

D. Fastening to In-Place Construction: Provide anchorage devices and fasteners where metal fabrications are required to be fastened to in-place construction. Provide threaded fasteners for use with concrete and masonry inserts, toggle bolts, through bolts, lag screws, wood screws, and other connectors.

E. Provide temporary bracing or anchors in formwork for items that are to be built into concrete, masonry, or similar construction.

F. Corrosion Protection: Coat concealed surfaces of aluminum that will come into contact with grout, concrete, masonry, wood, or dissimilar metals with the following:

1. Cast Aluminum: Heavy coat of bituminous paint.

2. Extruded Aluminum: Two coats of clear lacquer.

3.2 INSTALLING MISCELLANEOUS FRAMING AND SUPPORTS

A. General: Install framing and supports to comply with requirements of items being supported, including manufacturers' written instructions and requirements indicated on Shop Drawings.

3.3 INSTALLING METAL BOLLARDS

A. Anchor bollards in place as indicated on Drawings. Place concrete and vibrate or tamp for consolidation. Support and brace bollards in position until concrete has cured.

B. Fill bollards solidly with concrete, mounding top surface to shed water.

3.4 ADJUSTING AND CLEANING

A. Touchup Painting: Immediately after erection, clean field welds, bolted connections, and abraded areas. Paint uncoated and abraded areas with the same material as used for shop painting to comply with SSPC-PA 1 for touching up shop-painted surfaces.

1. Apply by brush or spray to provide a minimum 2.0-mil (0.05-mm) dry film thickness.

05 50 00 10 METAL FABRICATIONS

B. Touchup Painting: Cleaning and touchup painting of field welds, bolted connections, and abraded areas of shop paint are specified in Division 09 painting Sections.

C. Galvanized Surfaces: Clean field welds, bolted connections, and abraded areas and repair galvanizing to comply with ASTM A 780.

3.5 FIELD QUALITY CONTROL

A. Testing Agency: Contractor shall engage a qualified independent testing and inspecting agency to inspect field welds and bolted connections and to perform field tests and inspections and prepare test and inspection reports. All testing and inspections shall be performed in accordance with Section 01 40 00, Quality Requirements.

B. Field welds will be visually inspected according to AWS D1.1/D1.1M.

C. In addition to visual inspection, field welds will be tested according to AWS D1.1/D1.1M and the following procedures, as applicable:

1. Radiographic Testing: ASTM E 94.

2. Magnetic Particle Inspection: ASTM E 709.

3. Ultrasonic Testing: ASTM E 164.

4. Liquid Penetrant Inspection: ASTM E 165.

D. Bolted connections will be visually inspected.

E. Installation of all post-installed anchors shall be inspected in accordance with the manufacturer’s instructions beyond code requirements.

F. Correct deficiencies in Work that test and inspection reports have indicated are not in compliance with specified requirements.

END OF SECTION 05 50 00

PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
1. Steel framing and supports for applications where framing and supports are not specified in other Sections.
2. Shelf angles.
3. Metal ladders.
4. Miscellaneous steel trim including steel angle corner guards, steel edgings.
5. Metal bollards.
6. Loose bearing and leveling plates for applications where they are not specified in other Sections.
B. Products furnished, but not installed, under this Section:
1. Loose steel lintels.
2. Anchor bolts, steel pipe sleeves, and wedge-type inserts indicated to be cast into concrete or built into unit masonry.
3. Steel weld plates and angles for casting into concrete for applications where they are not specified in other Sections.
C. Related Sections:
1. Section 03 30 00, Cast-in-Place Concrete, for installing anchor bolts, steel pipe sleeves, slotted-channel inserts, wedge-type inserts, and other items cast into concrete.
2. Section 04 20 00, Unit Masonry, for installing loose lintels, anchor bolts, and other items built into unit masonry.
3. Section 05 12 00, Structural Steel Framing.
1.3 PERFORMANCE REQUIREMENTS
A. Delegated Design: Design ladders, including comprehensive engineering analysis by a qualified professional engineer, using performance requirements and design criteria indicated.
B. Thermal Movements: Allow for thermal movements from ambient and surface temperature changes acting on exterior metal fabrications by preventing buckling, opening of joints, overstressing of components, failure of connections, and other detrimental...
1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.
1.4 SUBMITTALS
A. Product Data: For the following:
1. Grout.
B. Submittals:
1. Building Submittal Requirements:
1) Product Data and Cut Sheets: Data and cut sheets shall be submitted for each product and accessory specified. Product data and cut sheets shall be marked with the Contractor’s stamp as confirmation that the submitted products are the products insta...
C. Shop Drawings: Show fabrication and installation details for metal fabrications.
1. Include plans, elevations, sections, and details of metal fabrications and their connections. Show anchorage and accessory items.
D. Delegated-Design Submittal: For installed products indicated to comply with performance requirements and design criteria, including analysis data signed and sealed by the qualified professional engineer responsible for their preparation.
E. Qualification Data: For qualified professional engineer.
F. Welding certificates.
1.5 QUALITY ASSURANCE
A. Welding Qualifications: Qualify procedures and personnel according to AWS D1.1/D1.1M, "Structural Welding Code - Steel."
1.6 PROJECT CONDITIONS
A. Field Measurements: Verify actual locations of walls and other construction contiguous with metal fabrications by field measurements before fabrication.
1.7 COORDINATION
A. Coordinate selection of shop primers with topcoats to be applied over them. Comply with paint and coating manufacturers' written recommendations to ensure that shop primers and topcoats are compatible with one another.
B. Coordinate installation of anchorages and items embedded into concrete and masonry. Furnish setting drawings, templates, and directions for installing anchorages, including sleeves, concrete inserts, anchor bolts, and items with integral anchors, ...
PART 2 - PRODUCTS
2.1 METALS, GENERAL
A. Metal Surfaces, General: Provide materials with smooth, flat surfaces unless otherwise indicated. For metal fabrications exposed to view in the completed Work, provide materials without seam marks, roller marks, rolled trade names, or blemishes.
2.2 FERROUS METALS
A. Recycled Content of Steel Products: Provide products with average recycled content of steel products so postconsumer recycled content plus one-half of preconsumer recycled content is not less than 25 percent.
B. Steel Plates, Shapes, and Bars: ASTM A 36/A 36M.
C. Steel Tubing: ASTM A 500, Grade B structural tubing.
D. Steel Pipe: ASTM A 53/A 53M, Type E or S, Grade B.
2.3 FASTENERS
A. General: Unless otherwise indicated, provide Type 304 stainless-steel fasteners for exterior use and zinc-plated fasteners with coating complying with ASTM B 633 or ASTM F 1941 (ASTM F 1941M), Class Fe/Zn 5, at exterior walls. Select fasteners fo...
B. Steel Bolts and Nuts: Regular hexagon-head bolts, ASTM A 307, Grade A (ASTM F 568M, Property Class 4.6); with hex nuts, ASTM A 563 (ASTM A 563M); and, where indicated, flat washers.
C. Stainless-Steel Bolts and Nuts: Regular hexagon-head annealed stainless-steel bolts, ASTM F 593 (ASTM F 738M); with hex nuts, ASTM F 594 (ASTM F 836M); and, where indicated, flat washers; Alloy Group 1 (A1).
D. Anchor Bolts: ASTM F 1554, Grade 36, of dimensions indicated; with nuts, ASTM A 563; and, where indicated, flat washers.
1. Hot-dip galvanize or provide mechanically deposited, zinc coating where item being fastened is indicated to be galvanized.
E. Plain Washers: Round, ASME B 18.22.1 (ASME B 18.22M).
F. Post-Installed Anchors: Wedge anchors, screw anchors, and adhesive anchors as indicated in the Drawings.
1. General:
a. Material for Interior Locations: Carbon-steel components zinc plated to comply with ASTM B 633 or ASTM F 1941 (ASTM F 1941M), Class Fe/Zn 5, unless otherwise indicated.
b. Material for Exterior Locations and Where Stainless Steel is Indicated: Alloy Group 1 (A1) stainless-steel bolts, ASTM F 593 (ASTM F 738M), and nuts, ASTM F 594 (ASTM F 836M).
c. Current evaluation and acceptance report by ICC or other similar code organization.
2. Wedge Anchors:
a. Manufacturers and Products:
1) ITW Ramset/Red Head, Addison, IL; Trubolt Wedge Anchor.
2) Hilti, Inc., Tulsa, OK; Kwik-Bolt-3 (KB-3) or Kwik-Bolt TZ Anchor.
3) Simpson Strong-Tie Co., Inc., Pleasanton, CA; Wedge-All or Strong-Bolt Wedge Anchor.
4) Or approved equal.
3. Adhesive Anchors:
a. Threaded Rod:
1) ASTM F593 stainless steel threaded rod, diameter as shown on Drawings.
2) Length as required, to provide minimum depth of embedment.
3) Clean and free of grease, oil, or other deleterious material.
4) For hollow-unit masonry, provide galvanized or stainless steel wire cloth screen tube to fit threaded rod.
b. Adhesive:
1) Adhesives shall pass the ICC-ES AC 308 test for long-term creep.
2) Two-component, designed to be used in adverse freeze/thaw environments, with gray color after mixing.
3) Cure Temperature, Pot Life, and Workability: Compatible for intended use and environmental conditions.
4) Nonsag, with selected viscosity base on installation temperature and overhead application where applicable.
c. Packaging and Storage:
1) Disposable, self-contained cartridge system capable of dispensing both components in the proper mixing ratio and fitting into a manually or pneumatically operated caulking gun.
2) Store adhesive cartridges on pallets or shelving in covered storage area, in accordance with manufacturer’s written instructions.
3) Cartridge Markings: Include manufacturer’s name, product name, material type, batch or serial number, and adhesive expiration date.
4) Dispose of cartridges if shelf life has expired.
d. Manufacturers and Products:
1) No “fast-set” epoxies shall be used.
2) Hilti, Inc., Tulsa, OK; HIT-HY-150-MAX Epoxy Adhesive Anchor System or HIT-RE-500SD Adhesive Anchors.
3) Simpson Strong-Tie Co., Inc., Pleasanton, CA; SET-XP Epoxy-Tie Adhesive.
4) Or approved equal.
4. Screw Anchors:
a. Manufacturers and Products:
1) Simpson Strong Tie Co., Inc., Pleasanton, CA; Titen HD Screw Anchor.
2) Or approved equal.
2.4 MISCELLANEOUS MATERIALS
A. Shop Primers: Provide primers that comply with Division 09 painting Sections.
B. Nonshrink, Nonmetallic Grout: Factory-packaged, nonstaining, noncorrosive, nongaseous grout complying with ASTM C 1107. Provide grout specifically recommended by manufacturer for interior and exterior applications.
2.5 FABRICATION, GENERAL
A. Shop Assembly: Preassemble items in the shop to greatest extent possible. Disassemble units only as necessary for shipping and handling limitations. Use connections that maintain structural value of joined pieces. Clearly mark units for reassem...
B. Cut, drill, and punch metals cleanly and accurately. Remove burrs and ease edges to a radius of approximately 1/32 inch (1 mm) unless otherwise indicated. Remove sharp or rough areas on exposed surfaces.
C. Form bent-metal corners to smallest radius possible without causing grain separation or otherwise impairing work.
D. Form exposed work with accurate angles and surfaces and straight edges.
E. Weld corners and seams continuously to comply with the following:
1. Use materials and methods that minimize distortion and develop strength and corrosion resistance of base metals.
2. Obtain fusion without undercut or overlap.
3. Remove welding flux immediately.
4. At exposed connections, finish exposed welds and surfaces smooth and blended so no roughness shows after finishing and contour of welded surface matches that of adjacent surface.
F. Form exposed connections with hairline joints, flush and smooth, using concealed fasteners or welds where possible. Where exposed fasteners are required, use Phillips flat-head (countersunk) fasteners unless otherwise indicated. Locate joints whe...
G. Fabricate seams and other connections that will be exposed to weather in a manner to exclude water. Provide weep holes where water may accumulate.
H. Cut, reinforce, drill, and tap metal fabrications as indicated to receive finish hardware, screws, and similar items.
I. Provide for anchorage of type indicated; coordinate with supporting structure. Space anchoring devices to secure metal fabrications rigidly in place and to support indicated loads.
1. Where units are indicated to be cast into concrete or built into masonry, equip with integrally welded steel strap anchors, 1/8 by 1-1/2 inches (3.2 by 38 mm), with a minimum 6-inch (150-mm) embedment and 2-inch (50-mm) hook, not less than 8 inches...
2.6 MISCELLANEOUS FRAMING AND SUPPORTS
A. General: Provide steel framing and supports not specified in other Sections as needed to complete the Work.
B. Fabricate units from steel shapes, plates, and bars of welded construction unless otherwise indicated. Fabricate to sizes, shapes, and profiles indicated and as necessary to receive adjacent construction.
1. Fabricate units from slotted channel framing where indicated.
2. Furnish inserts for units installed after concrete is placed.

C. Prime miscellaneous framing and supports with Division 09 painting Sections.

2.7 METAL LADDERS
A. General: Comply with ANSI A 14.3 and OSHA requirements unless otherwise indicated.
B. Steel Ladders:
1. Space siderails 18 inches (457 mm) apart unless otherwise indicated.
2. Siderails: Continuous, 3/8-by-2-1/2-inch (9.5-by-64-mm) steel flat bars, with eased edges.
3. Rungs: 1-inch- (25-mm-) diameter steel bars.
4. Fit rungs in centerline of siderails; plug-weld and grind smooth on outer rail faces.
5. Provide nonslip surfaces on top of each rung by coating with abrasive material metallically bonded to rung.
6. Support each ladder at top and bottom and not more than 60 inches (1500 mm) o.c. with welded or bolted steel brackets.
7. Prime interior ladders, including brackets and fasteners, with primer specified in Division 09 painting Sections.
8. Exterior ladders shall be hot dip galvanized after fabrication, then primed, as specified in Division 09 painting Sections.
2.8 MISCELLANEOUS STEEL TRIM
A. Unless otherwise indicated, fabricate units from steel shapes, plates, and bars of profiles shown with continuously welded joints and smooth exposed edges. Miter corners and use concealed field splices where possible.
B. Provide cutouts, fittings, and anchorages as needed to coordinate assembly and installation with other work.
1. Provide with integrally welded steel strap anchors for embedding in concrete or masonry construction.

C. Prime miscellaneous steel trim with primer specified in Division 09 painting Sections.

2.9 METAL BOLLARDS
A. Fabricate metal bollards from Schedule 40 steel pipe.
1. Where bollards are indicated to receive controls for door operators, provide necessary cutouts for controls and holes for wire.
2. Where bollards are indicated to receive light fixtures, provide necessary cutouts for fixtures and holes for wire.

B. Prime bollards with primer specified in Division 09 painting Sections.

2.10 LOOSE STEEL LINTELS
A. Fabricate loose steel lintels from steel angles and shapes of size indicated for openings and recesses in masonry walls and partitions at locations indicated. Fabricate in single lengths for each opening unless otherwise indicated. Weld adjoining...
B. Galvanize loose steel lintels located in exterior walls.
2.11 STEEL WELD PLATES AND ANGLES
A. Provide steel weld plates and angles not specified in other Sections, for items supported from concrete construction as needed to complete the Work. Provide each unit with no fewer than two integrally welded steel strap anchors for embedding in co...
2.12 FINISHES, GENERAL
A. Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations for applying and designating finishes.
B. Finish metal fabrications after assembly.
C. Finish exposed surfaces to remove tool and die marks and stretch lines, and to blend into surrounding surface.
2.13 STEEL AND IRON FINISHES
A. Galvanizing: Hot-dip galvanize items as indicated to comply with ASTM A 153/A 153M for steel and iron hardware and with ASTM A 123/A 123M for other steel and iron products.
1. Do not quench or apply post galvanizing treatments that might interfere with paint adhesion.
B. Shop prime iron and steel items not indicated to be galvanized unless they are to be embedded in concrete, or masonry, or unless otherwise indicated.
1. Shop prime with primers specified in Division 09 painting Sections.
C. Preparation for Shop Priming: Prepare surfaces to comply with SSPC-SP 3, "Power Tool Cleaning."
D. Shop Priming: Apply shop primer to comply with SSPC-PA 1, "Paint Application Specification No. 1: Shop, Field, and Maintenance Painting of Steel," for shop painting.
1. Stripe paint corners, crevices, bolts, welds, and sharp edges.
PART 3 - EXECUTION
3.1 INSTALLATION, GENERAL
A. Cutting, Fitting, and Placement: Perform cutting, drilling, and fitting required for installing metal fabrications. Set metal fabrications accurately in location, alignment, and elevation; with edges and surfaces level, plumb, true, and free of r...
B. Fit exposed connections accurately together to form hairline joints. Weld connections that are not to be left as exposed joints but cannot be shop welded because of shipping size limitations. Do not weld, cut, or abrade surfaces of exterior units...
C. Field Welding: Comply with the following requirements:
1. Use materials and methods that minimize distortion and develop strength and corrosion resistance of base metals.
2. Obtain fusion without undercut or overlap.
3. Remove welding flux immediately.
4. At exposed connections, finish exposed welds and surfaces smooth and blended so no roughness shows after finishing and contour of welded surface matches that of adjacent surface.
D. Fastening to In-Place Construction: Provide anchorage devices and fasteners where metal fabrications are required to be fastened to in-place construction. Provide threaded fasteners for use with concrete and masonry inserts, toggle bolts, through...
E. Provide temporary bracing or anchors in formwork for items that are to be built into concrete, masonry, or similar construction.
F. Corrosion Protection: Coat concealed surfaces of aluminum that will come into contact with grout, concrete, masonry, wood, or dissimilar metals with the following:
1. Cast Aluminum: Heavy coat of bituminous paint.
2. Extruded Aluminum: Two coats of clear lacquer.
3.2 INSTALLING MISCELLANEOUS FRAMING AND SUPPORTS
A. General: Install framing and supports to comply with requirements of items being supported, including manufacturers' written instructions and requirements indicated on Shop Drawings.
3.3 INSTALLING METAL BOLLARDS
A. Anchor bollards in place as indicated on Drawings. Place concrete and vibrate or tamp for consolidation. Support and brace bollards in position until concrete has cured.
B. Fill bollards solidly with concrete, mounding top surface to shed water.
3.4 ADJUSTING AND CLEANING
A. Touchup Painting: Immediately after erection, clean field welds, bolted connections, and abraded areas. Paint uncoated and abraded areas with the same material as used for shop painting to comply with SSPC-PA 1 for touching up shop-painted surfaces.
1. Apply by brush or spray to provide a minimum 2.0-mil (0.05-mm) dry film thickness.
B. Touchup Painting: Cleaning and touchup painting of field welds, bolted connections, and abraded areas of shop paint are specified in Division 09 painting Sections.
C. Galvanized Surfaces: Clean field welds, bolted connections, and abraded areas and repair galvanizing to comply with ASTM A 780.
3.5 FIELD QUALITY CONTROL
A. Testing Agency: Contractor shall engage a qualified independent testing and inspecting agency to inspect field welds and bolted connections and to perform field tests and inspections and prepare test and inspection reports. All testing and inspec...
B. Field welds will be visually inspected according to AWS D1.1/D1.1M.
C. In addition to visual inspection, field welds will be tested according to AWS D1.1/D1.1M and the following procedures, as applicable:
1. Radiographic Testing: ASTM E 94.
2. Magnetic Particle Inspection: ASTM E 709.
3. Ultrasonic Testing: ASTM E 164.
4. Liquid Penetrant Inspection: ASTM E 165.
D. Bolted connections will be visually inspected.
E. Installation of all post-installed anchors shall be inspected in accordance with the manufacturer’s instructions beyond code requirements.
F. Correct deficiencies in Work that test and inspection reports have indicated are not in compliance with specified requirements.