This document package includes construction drawings and specifications for an addition to an F-22 Composite Repair Facility at Joint Base Pearl Harbor-Hickam in Hawaii. The project involves demolishing existing structures and pavements, installing new micropiles and pile caps, and constructing a new addition with reinforced concrete and structural steel framing. The Army National Guard is the contracting agency. The construction is for a project awarded under contract number W9133L-15-D-0003. The drawings provide details for demolition plans, pavement layout and construction, foundation plans and details, and structural framing plans. Fire suppression system requirements are also included.
Addendum 01 Drawings
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FEBRUARY 2019
FINAL SUBMITTAL
CONTRACT: W9133L-15-D-0003
GUARDING AMERICA
DEFENDING FREEDOM
TFI - F-22 Squadron
CNS ADD TO F-22
LOCRF, B3408
Oahu, Hawaii
JOINT BASE PEARL HARBOR - HICKAM
Hawaii Air National Guard
Project No. - KNMD189008
BID ADDENDUM 01
AUGUST 2019
D
C
B
D
C B
T
T
T
E
S
E
S
G G
G
G
G
G G
G G
G
G
G G
GG
G G
G
E
S
E
S
S W
B D
G
E
S
E
S
E S
ES
ES
E
S
E
S
E
S
E
S
E
S
ES
ES
E
S
E
S
E
S
E
S
J
J
M
J
HBHB
HB
HB
HB
HD
E
U
E
U
S
HA
HA
HA
HA
LC3
HA
E
U
E
U
C B
REMOVE WATER LINE
N 55634.20
E 1655766.29
WEAPONS
LOADING
TRAINING
(WLT)
EXISTING
LO/CRF BAY 2
12.65m
[41.48'] m m
N 55534.09
E 1655643.42
3.40m
[11.15']
E 1655503.21
N 55560.98
E 1655524.81
N 55580.64
E 1655556.00
N 55580.64
E 1655591.68
REMOVE WATER LINE
N 55626.55
2.98m
[9.78']
REMOVE ELECTRICAL HANDHOLE
AND CONDUIT BENEATH PROPOSED
SITE LAYOUT
N 55591.20
E 1655598.21
EXISTING FIRE
HYDRANT
TO REMAIN
REMOVE UNDERGROUND
200mm [8"] PVC STORM DRAIN LINE
RELOCATE EXISTING LOW-PROFILE
FIRE HYDRANT AND
150mm [6"] WATER LINE
REMOVE 300mm [12"]
HDPE WATER LINE
SEE ENLARGED DEMOLITION
PLAN ON SHEET CD101
BID OPTION 6: SUNSHADE REMOVAL
CONTRACTOR SHALL DISASSEMBLE
EXISTING AIRCRAFT SUNSHADE,
PALLETIZE, AND RETURN TO THE
GOVERNMENT
EXISTING
SCREEN WALL
AND
FOUNDATION
TO REMAIN
EXISTING SUNSHADES TO REMAIN
EXISTING
SUNSHADES TO
REMAIN
BID OPTION 6
SUNSHADE REMOVAL:
REMOVE AIRFIELD
PAVEMENT MARKING
REMOVE LANDSCAPE
AND DECORATIVE
LANDSCAPE CURBING
m
E 1655574.18
N 55597.80
REMOVE EXISTING SIDEWALK
PAVEMENT FOR MECHANICAL PAD
FOUNDATION (SEE SHEET CS101)
CLEARING FOR
MECHANICAL
ENCLOSURE
FIREWATER LINE (SEE NOTE 2)
VERIFY LOCATION WITH
CONTRACTING OFFICER PRIOR
TO ANY DEMOLITION WORK
AIRFIELD CONCRETE PAVEMENT DEMOLITION
(SEE NOTE 15)
AIRFIELD ASPHALT SHOULDER DEMOLITION
(SEE NOTE 15)
SITE CONCRETE PAVEMENT DEMOLITION
(SEE NOTE 16)
SIDEWALK PAVEMENT DEMOLITION
(SEE NOTE 16)
DEMOLITION LEGEND
PAVEMENT MARKING REMOVAL
UTILITY REMOVAL
date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
C O
P Y
R I G
H T
B
U R
N S
A
M c D
O N
N E
L L
E
N G
I N
E E
R I N
G
C
O M
P A
N Y
I N
C
C
DATEREV.
REVISIONS
DESCRIPTION INIT
HAWAII AIR NATIONAL GUARD
JOINT BASE PEARL HARBOR - HICKAM
OAHU, HAWAII
KANSAS CITY, MISSOURI
ENGINEERS ARCHITECTS & CONSULTANTS
88276
Project No. - KNMD189008
W9133L-15-D-0003
CONSTRUCT ADDITION TO
F-22 LO/CRF, B3408
FEBRUARY 2019
5 6
D
C
A
B
1 2 3 4
E
D
C
A
B
E
5 61 2 3 4
AP0
REVISED FINAL
SUBMITTAL (CODE CHECK)02/14/2019
N
1. BUILDING DEMOLITION INCLUDES ALL INTERIOR WALLS, ROOF STRUCTURE,
MECHANICAL, ELECTRICAL EQUIPMENT AND ALL EXTERIOR WALLS. CONTRACTOR
SHALL REMOVE BUILDING SLAB, FOUNDATION, PAVEMENTS AND BELOW GRADE
STRUCTURES IN THEIR ENTIRETY. FILL ALL EXCAVATIONS WITH COMPACTED
SATISFACTORY MATERIAL IN ACCORDANCE WITH SPECIFICATION SECTION 31 20 00
SITE PREPARATION AND EARTHWORK. CONTRACTOR TO FOLLOW ALL FEDERAL,
STATE, LOCAL AND SPECIFICATION REQUIREMENTS IN THE DEMOLITION, HANDLING,
DISPOSAL OF CONTAMINATED OR HAZARDOUS MATERIAL AND WASTE.
2. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING UTILITY LOCATIONS BEFORE
BEGINNING DEMOLITION. EXISTING UTILITIES NOTED TO BE ABANDONED IN PLACE
SHALL BE CAPPED AND PLUGGED WITH WATER TIGHT SEAL. UTILITY MANHOLES AND
INLETS ON LINES TO BE ABANDONED IN PLACE SHALL BE REMOVED. CONTRACTOR
SHALL REMOVE ANY EXISTING UTILITIES, NOTED TO BE ABANDONED, IF THEY
INTERFERE WITH NEW CONSTRUCTION OF UTILITIES OR BUILDING FOUNDATIONS,
CONTACT CONTRACTING OFFICER IF UNKNOWN UTILITIES ARE ENCOUNTERED.
CONTRACTING OFFICER TO NOTIFY IN WRITING OF REQUIRED ACTION.
3. PAVEMENT INDICATED FOR DEMOLITION INCLUDES COMPLETE REMOVAL OF ASPHALT
PAVEMENT, CONCRETE PAVEMENT, CURB AND GUTTER AND AGGREGATE BASE
MATERIAL.
4. ALL SCRAP METAL SHALL BE RECYCLED OFF BASE. CONTRACTOR SHALL PROVIDE THE
WEIGHT OF ALL DEMOLITION DEBRIS AND RECYCLED SCRAP METAL TO THE
CONTRACTING OFFICER.
5. THE WEIGHT OF CONCRETE TAKEN OFF BASE FOR RECYCLING SHALL BE REPORTED
TO THE CONTRACTING OFFICER. THE WEIGHT OF ALL CONCRETE THAT IS DISPOSED
OF AS SOLID WASTE SHALL ALSO BE REPORTED TO THE CONTRACTING OFFICER AS
DEMOLITION DEBRIS.
6. SEE SPECIFICATION SECTION 02 41 00 FOR ADDITIONAL INFORMATION ON DEMOLITION
WORK FOR BUILDINGS, PAVEMENTS, UTILITIES, ETC.
7. ALTHOUGH NOT ANTICIPATED, IF CONTRACTOR ENCOUNTERS CONTAMINATED
SOIL/FUEL; CONTACT CONTRACTING OFFICER AND BASE ENVIRONMENTAL
DEPARTMENT, AND IF REQUIRED BY HAWAII DEPARTMENT OF ENVIRONMENTAL
PROTECTION REGULATIONS AND CONTRACTING OFFICER. REMOVE ALL
CONTAMINATED MATERIAL PER STATE AND FEDERAL REGULATIONS AND CONTRACT
SPECIFICATIONS.
8. CONTRACTOR IS REQUIRED TO OBTAIN A STORMWATER GENERAL PERMIT FOR LAND
DISTURBANCE OF MORE THAN 1 ACRE FROM DEPARTMENT OF ENVIRONMENTAL
QUALITY. SEE ENVIRONMENTAL PROTECTION AND DRAFT STORMWATER POLLUTION
PREVENTION PLAN INCLUDED IN THE SPECIFICATIONS.
9. SEE TYPICAL DETAIL ON CU500 FOR ANY TRENCHING OF EXISTING PAVEMENTS FOR
UTILITY INSTALLATIONS.
10. SEE SITE ELECTRICAL DEMOLITION DRAWING FOR DEMOLITION OF ELECTRICAL,
GROUNDING AND COMMUNICATION LINES.
11. ANY DAMAGE TO PAVEMENT AREAS DESIGNATED TO REMAIN SHALL BE REPAIRED OR
REPLACED AT THE CONTRACTOR'S EXPENSE.
12. EXISTING VEGETATION WHICH ARE TO REMAIN SHALL BE PROTECTED FROM
DEMOLITION OR OTHER CONSTRUCTION ACTIVITIES.
13. SAWCUT THE EXISTING PAVEMENT FULL DEPTH AT THE DEMOLITION LIMITS TO
MINIMIZE DAMAGE TO THE PAVEMENT TO REMAIN AROUND THE PAVEMENT REMOVAL
LIMITS. CONTRACTOR SHALL COORDINATE LIMITS OF SAWCUT AND PAVEMENT
REMOVAL WITH PROPOSED PAVEMENT LAYOUT AND JOINTING PLAN. PAVEMENT
DESIGNATED FOR SAWCUT SHALL BE SAWCUT FULL DEPTH. EXISTING PAVEMENT
EDGES SHALL BE SAWCUT IN LOCATIONS SHOWN TO PROVIDE CLEAN EDGE FOR
CONSTRUCTION OF PROPOSED PAVEMENT. EXISTING AIRFIELD PAVEMENTS THAT
NEED TO BE REMOVED SHALL BE DOUBLE SAWCUT. INITIAL FULL DEPTH SAWCUT AT
THE LIMITS OF REMOVAL AND A SECOND FULL DEPTH SAWCUT 450mm [18"] FROM THE
INITIAL SAWCUT. SAWCUT EXISTING CONCRETE AT EXISTING JOINT LINES TO THE
MAXIMUM EXTENT POSSIBLE TO PREVENT PARTIAL PANEL REMOVAL UNLESS
INDICATED OTHERWISE ON THE DEMOLITION DRAWINGS.
14. PAVEMENT REMOVAL SHALL INCLUDE REMOVAL OF PAVEMENT AND ANY SUBBASE
MATERIAL PRESENT. EXISTING AIRFIELD CONCRETE PAVEMENT IS APPROXIMATELY
355mm [14"] PCC ON 180mm [7"] AGGREGATE BASE. EXISTING AIRFIELD ASPHALT
SHOULDER PAVEMENT IS APPROXIMATELY 150mm [6"] ASPHALT ON 150mm [6"]
AGGREGATE BASE.
15. SITE PAVEMENT REMOVAL SHALL INCLUDE REMOVAL OF PAVEMENT, BASE ROCK, AND
ANY SUBBASE MATERIAL PRESENT. EXISTING SITE CONCRETE PAVEMENT IS
APPROXIMATELY 225mm [9"] CONCRETE ON 150mm [6"] AGGREGATE BASE EXISTING
SIDEWALK PAVEMENT IS APPROXIMATELY 100mm [4"] CONCRETE ON 100mm [4"]
AGGREGATE BASE.
16. ANY DAMAGE TO PAVEMENT AREAS DESIGNATED TO REMAIN SHALL BE REPAIRED OR
REMOVED AND REPLACED AT THE CONTRACTOR'S EXPENSE. REPAIRED/REPLACED
PAVEMENT SECTION SHALL MATCH ADJACENT SECTION AND SHALL BE DONE IN FULL
PANELS.
17. EXISTING FACILITIES WHICH ARE NOT INDICATED TO BE REMOVED SHALL BE
PROTECTED FROM DEMOLITION OR OTHER CONSTRUCTION ACTIVITIES.
18. SPECIAL HANDLING AND CONSIDERATION SHALL BE REQUIRED FOR EXCAVATED SOILS
THOUGHT TO CONTAIN PETROLEUM-BASED/CONTAMINATED/HAZARDOUS
SUBSTANCES. CONTRACTOR SHALL MONITOR EXCAVATED SOILS. SOILS SHALL BE
TREATED ON SITE OR DISPOSED OF PROPERLY IN ACCORDANCE WITH ALL FEDERAL,
STATE, AND LOCAL REQUIREMENTS AND THE PROJECT SPECIFICATIONS.
CONTRACTOR SHALL COORDINATE REMOVAL OF PETROLEUM-BASED /
CONTAMINATED / HAZARDOUS MATERIALS WITH CONTRACTING OFFICER.
19. THE WEIGHT (IN TONS) OF ALL MATERIALS TAKEN OFF BASE FOR REMOVAL SHALL BE
REPORTED TO THE CONTRACTING OFFICER ON A WEEKLY BASIS.
20. CONTRACTOR SHALL COORDINATE WITH THE CONTRACTING OFFICER PRIOR TO
REMOVAL OF EXISTING UTILITIES IN SERVICE. RELOCATED UTILITIES SHALL BE
CONSTRUCTED BEFORE REMOVAL OF EXISTING UTILITIES TO ENSURE
UNINTERRUPTED SERVICE TO THE FACILITIES SERVED BY THE UTILITY. ALL
RELOCATIONS SHALL BE COORDINATED WITH THE CONTRACTING OFFICER A MINIMUM
OF 3 WEEKS PRIOR TO ANTICIPATED UTILITY WORK.
21. ALL STRUCTURES, VALVES, ETC. TO REMAIN SHALL BE PROTECTED AND ADJUSTED TO
FINISH GRADE.
22. THE LOCATIONS OF STRUCTURES AND UNDERGROUND UTILITIES AS INDICATED HAVE
BEEN OBTAINED FROM EXISTING RECORDS AND FIELD SURVEYS. UNDERGROUND
STRUCTURES AND UTILITIES MAY BE PRESENT WHICH ARE NOT DOCUMENTED OR
LOCATED.
23. THE CONTRACTOR IS RESPONSIBLE FOR PROTECTING ITEMS NOT TO BE DAMAGED
DURING DEMOLITION AND CONSTRUCTION. THE CONTRACTOR SHALL REPAIR OR
REPLACE DAMAGED OR DISTURBED ITEMS TO THE SATISFACTION OF THE
CONTRACTING OFFICER.
DEMOLITION NOTES:
40'10'0 20'
KNMD159060CD100.DWG
R. BARUTHK. WARTA
D. MUETING
0CD100
AutoCAD SHX Text
YELLOW LINE
AutoCAD SHX Text
UG
AutoCAD SHX Text e
AutoCAD SHX Text
UG
AutoCAD SHX Text e
AutoCAD SHX Text
OVERALL SITE DEMOLITION PLAN
kwarta Cloud
F
P
R
E
L
I
M
F
P
E
L
I
M
D
D
EXISTING LO/CRF BAY 2
C B
LO/CRF
7.62m
[25.00']
EXISTING
CONCRETE SIDEWALK
EXISTING AIRFIELD
ASPHALT SHOULDER
REMOVE
STORMWATER
CATCH BASIN
EXISTING
CONCRETE SIDEWALK
REMOVE WATER LINE
REMOVE WATER LINE
RELOCATE
EXISTING
LOW-PROFILE
FIRE HYDRANT
(SEE CU100)
REMOVE
UNDERGROUND
200mm[8"] PVC
STORM DRAIN LINE
SEE NOTE 2
BID OPTION 6 SUNSHADE REMOVAL:
CONTRACTOR SHALL DISASSEMBLE
EXISTING AIRCRAFT SUNSHADE,
PALLETIZE, AND RETURN TO
GOVERNMENT.
SEE SHEET
CD100 FOR SITE
CONCRETE
DEMOLITION
EXISTING CONCRETE
SIDEWALK TO
REMAIN
REMOVE WATER LINE
N 55534.32
E 1655643.41
N 55522.70
E 1655697.25
N 55541.36
E 1655704.06
N 55521.67
E 1655757.83
N 55540.56
E 1655764.72
N 55522.44
E 1655814.45
N 55609.64
E 1655808.71
E 1655815.70
N 55628.44
N 55647.26
E 1655764.23
N 55666.16
E 1655771.00
N 55672.91
E 1655752.19
N 55678.43
E 1655749.45
N 55681.32
E 1655736.02
N 55683.19
E 1655643.30
N 55533.79
E 1655617.59
N 55542.25
E 1655643.47
N 55597.98
E 1655583.81
N 55598.43
E 1655617.69
N 55598.76
E 1655642.11
N 55683.59
E 1655673.21
N 55638.38
E 1655673.81
N 55603.69
E 1655825.55
E 1655590.66
CUT, CAP, AND GROUT FILL
EXISTING WATER LINE TO EAST
N 55626.61
E 1655644.03
CUT, CAP, AND GROUT FILL
EXISTING WATER LINE TO WEST
N 55627.16
N 55565.89
E 1655811.97
N 55559.83
E 1655828.45
REMOVE ROOF DRAIN
DOWNSPOUT SEE
ARCHITECTURAL SHEETS
GROUT FILL
WATER LINE
REMOVE SITE CONCRETE
FOR ELECTRICAL DUCT
BANK, INSTALL H-20
TRAFFIC RATED STEEL
PLATE OVER SIDEWALK
PANEL REMOVED UNTIL
CONCRETE IS POURED
REMOVE WATER
LINE REDUCER AND
150mm [6mm] ALINE
AND BEND TO FIRE
HYDRANT
EXISTING FIRE
HYDRANT TO
REMAIN
SAWCUT FULL DEPTH
REMOVE ROOF
DRAIN/DOWNSPOUT - SEE
ARCHITECTURAL SHEETS
CUT AND REMOVE EXISTING
DOWNSPOUT/DOWNSPOUT
DRAIN TO GRADE
CUT,CAP, AND GROUT FILL
UNDERGROUND 200m [8"] PVC DRAIN
LINE TO EAST
N 55676.80
E 1655723.45
EXISTING WATER LINE
BENEATH AIRFIELD
PAVEMENT TO REMAIN
N 55634.69
E 1655766.41
DOUBLE SAWCUT FULL
DEPTH CONCRETE AT
EXISTING PAVEMENT
JOINTS SEE (SEE NOTE
ON SHEET CD100)
SAWCUT AND REMOVE
SIDEWALK PAVEMENT FOR
MECHANICAL PAD LEGS - 6
TOTAL (SEE CS101 FOR
LOCATIONS)
REMOVE EXISTING
CONDENSATE PIT
E 1655635.21
N 55617.52
CAP EXISTING STORM
DRAIN LINE TO THE EAST OF
ROOF DRAIN CONNECTS
SEE NOTE 3
FIREWATER LINE (SEE NOTE 2 ON
SHEET CD100) VERIFY LOCATION
WITH CONTRACTING OFFICER PRIOR
TO ANY DEMOLITION WORK
AIRFIELD CONCRETE PAVEMENT DEMOLITION
(SEE NOTE 15)
AIRFIELD ASPHALT SHOULDER DEMOLITION
(SEE NOTE 15)
SITE CONCRETE PAVEMENT DEMOLITION
(SEE NOTE 16)
SIDEWALK PAVEMENT DEMOLITION
(SEE NOTE 16)
DEMOLITION LEGEND
PAVEMENT MARKING REMOVAL
UTILITY REMOVAL
, SHEET CD100)
, SHEET CD100)
, SHEET CD100)
, SHEET CD100)
date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
C O
P Y
R I G
B
U R
D
O N
N E
L L
E
N G
I N
E E
R I N
G
C
O M
P A
N Y
I N
C
C
DATEREV.
REVISIONS
DESCRIPTION INIT
HAWAII AIR NATIONAL GUARD
JOINT BASE PEARL HARBOR - HICKAM
OAHU, HAWAII
KANSAS CITY, MISSOURI
ENGINEERS ARCHITECTS & CONSULTANTS
88276
Project No. - KNMD189008
W9133L-15-D-0003
CONSTRUCT ADDITION TO
F-22 LO/CRF, B3408
FEBRUARY 2019
5 6
D
C
A
B
1 2 3 4
E
D
C
A
B
E
5 61 2 3 4
AP0
REVISED FINAL
SUBMITTAL (CODE CHECK)02/14/2019
0 20'10'
N
1. SEE GENERAL DEMOLITION NOTES ON CD100.
2. FOR FINAL LOCATION AND INTERIM LOCATION OF MECHANICAL EQUIPMENT
SEE MECHANICAL DRAWINGS.
3. ALL AREAS DISTURBED BY ANY CONSTRUCTION ACTIVITIES INCLUDING
BORROW AREAS, STOCKPILE AREAS, MATERIAL LAYDOWN , EQUIPMENT
PARKING, CONTRACTOR PARKING, EARTHWORK ACTIVITIES, UTILITY
TRENCHING, OVERHEAD UTILITY WORK, ETC SHALL BE RESTORED TO BETTER
THAN EXISTING CONDITIONS. ALL GRASS AREAS DISTURBED SHALL BE
COVERED WITH A MINIMUM 100mm [4"] OF TOPSOIL, SEEDED, AND
IRRIGATED/MAINTAINED FOR A MINIMUM OF 90 DAYS AND UNTIL 70%
COVERAGE OF AROUND COVER.
NOTES:
KNMD159060CD101.DWG
0CD101
AutoCAD SHX Text
ENLARGED DEMOLITION PLAN
HB
B
D
D
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
A
E
E
E
E
A
E
E
E
E
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
E
E
E
E
E
E
E
E
E
E
E
B
B
E
E
E
E
E
E
E
A
A
A
A
A
A
A
E
A
A
A
A
A
A A
A
A
A
A
A
A
E
D
E
E
E
E
B
E
E
E
E
E
E
E
A
A
A
A
A
A
A
G
C
C
C
C
C
C
G
C
C
B
B
B
B
C
C
G
C
C
C
C
C
C
G
G
E
E
E
E
E
E
E
E
E
E
G
C
C
E
E
B
B
B
B
E
E
E
B
B
B
B
E
E
B
E
A
A
A A
E
E
D D
D D
D
D D
D D
D
D D
D D
D
D D
D D
D
D
D
D
D
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
F
F F
D
D
E
D
D
D
D
D
D
D
D
E
D
E
E
E
E
E
E
D
D
D
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
D
E
D
D
D D
D
A
A
A
A
A
B
B
B
B
B
B
B
D
D
B
B
B
B
B
B
B
D
A
D
A
A
A
A
A
A
A
A
A
G
G
G
G
G
G
G
G
G
E
E
E
G
G
B
B
D
B
B
A
AA
A
A
A
A
B
B
A
A
A
E
E
A
A
A
A
A
A A
A
A
A
A
A
A
EXISTING
CONCRETE
SIDEWALK
(TO REMAIN)
EXISTING SITE
VEHICULAR CONCRETE
PAVEMENT (TO REMAIN)
EXISTING CONCRETE
SIDEWALK
(TO REMAIN)
CONCRETE
PAVEMENT
JOINTING FOR DOOR TRACK/SLAB
PER MANUFACTURER'S
RECOMMENDATIONS
FOR ADDITIONAL INFORMATION
SEE STRUCTURAL SHEET S-112
RELOCATED MECHANICAL
EQUIPMENT
JOINTING FOR DOOR TRACK/SLAB
PER MANUFACTURER'S
RECOMMENDATIONS
FOR ADDITIONAL INFORMATION
SEE STRUCTURAL SHEET S-112
EXISTING LO/CRF
BAY 1
EXISTING
ASPHALT
SHOULDER
(TO REMAIN)
LO/CRF
EXISTING CONCRETE
AIRFIELD PAVEMENT
EXISTING GRASS
AREA
(TO REMAIN)
N 55572.58
E 1655715.86
N 55572.30
E 1655699.79
N 55572.12
E 1655689.87
N 55595.72
E 1655675.64
N 55596.13
E 1655699.37
N 55596.75
E 1655735.16
N 55616.24
E 1655715.06
N 55615.96
E 1655699.03
N 55615.79
E 1655689.10
N 55596.28
E 1655715.41
D date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
C O
P Y
R I G
B
U R
D
O N
N E
L L
E
N G
I N
E E
R I N
G
C
O M
P A
N Y
I N
C
C
DATEREV.
REVISIONS
DESCRIPTION INIT
HAWAII AIR NATIONAL GUARD
JOINT BASE PEARL HARBOR - HICKAM
OAHU, HAWAII
KANSAS CITY, MISSOURI
ENGINEERS ARCHITECTS & CONSULTANTS
88276
Project No. - KNMD189008
W9133L-15-D-0003
CONSTRUCT ADDITION TO
F-22 LO/CRF, B3408
FEBRUARY 2019
5 6
D
C
A
B
1 2 3 4
E
D
C
A
B
E
5 61 2 3 4
AP0
REVISED FINAL
SUBMITTAL (CODE CHECK)02/14/2019
0 20'10'
N
NOTES:
1. CONTRACTOR SHALL REINFORCE ALL CONCRETE SLABS THAT HAVE
MANHOLES, CLEANOUTS, GUARD POSTS, MECHANICAL/ELECTRICAL
PADS, OR ARE IRREGULAR IN SHAPE OR AS DIRECTED BY THE
CONTRACTING OFFICER. SEE DETAIL A5 ON DRAWING CS501.
2. CONTRACTOR SHALL PROVIDE THICKENED EDGE EXPANSION JOINTS
AROUND UTILITY STRUCTURES, INLETS VAULTS AND FOUNDATIONS.
SEE DETAIL E3 ON DRAWING CS502.
3. ALL JOINT CHANGES SHALL BE SUBMITTED TO THE CONTRACTING
OFFICER AND DESIGNER OF RECORD FOR WRITTEN APPROVAL A
MINIMUM OF 14 DAYS PRIOR TO PAVEMENT CONSTRUCTION.
4. CONTRACTOR SHALL VERIFY ELEVATIONS AT TIE-IN AND/OR MATCH
POINTS PRIOR TO STARTING ANY PAVEMENT SECTION CONSTRUCTION
INCLUDING SUBGRADE PREPARATION, BASE COURSE, AND/OR
DRAINAGE COURSE.
5. NOT USED.
6. SEE DETAIL H1 ON SHEET CS500 FOR ADDITIONAL INFORMATION ON
JOINTS NEAR FILLETS AND ODD SHAPED PANELS.
7. ALL JOINT SEALANT FOR VEHICULAR SITE CONCRETE PAVEMENT SHALL
BE PER SPECIFICATION 32 01 19 AND DETAILS B1, B2, AND B3 ON CS502.
LEGEND:
DOWELED CONSTRUCTION JOINT
DOWELED CONTRACTION JOINT
DUMMY CONTRACTION JOINT
REINFORCED SLAB
TIE DOWN
UTILITY MANHOLE/STRUCTURE
THICKENED EDGE ISOLATION JOINT
C
E
B
AIRCRAFT GROUNDING POINTS
(SEE ELECTRICAL DRAWINGS)
F NEW CONCRETE TO AC TRANSITION
N2
CS500
K3
CS500
N1
CS500
K2
CS500
N4
CS500
A ISOLATION JOINT AT FOUNDATION
K4
CS500
THICKENED EDGE AT DOOR TRACK
B1 S-112
N3
CS500
G
KNMD159060CS401.DWG
0CS401
AGGREGATE BASE COURSE (GCA)
PORTLAND CEMENT CONCRETE
CONSTRUCT A TYPE D JOINT WHENEVER
PAVING OPERATIONS ARE DELAYED OR STOPPED.
OF DOWEL
GREASE ONE END
AT LEAST 48 HOURS AFTER PAVEMENT
CONCRETE SHALL NOT BE DRILLED UNTIL
"T"
WITH "R" ONLY
DESIGNATED
FOR SLABS
PLACEMENT.
NOTES:
2.
1.
GRADED CRUSHED AGGREGATE
PORTLAND CEMENT CONCRETE
T
SEE TABLE A
L/2
T mm [IN]
GRADED, CRUSHED
NON-EXTRUDING
PREMOLDED
COMPRESSIBLE
MATERIAL
EXISTING ADJOINING
PAVEMENT/SIDEWALK
SEE TABLE B
TABLE B: REINFORCED SLABS
TO NEAREST JOINT
NON-EXTRUDING PREFORMED
COMPRESSIBLE MATERIAL
FOUNDATION OR
STRUCTURE
BUT NOT LESS THAN
3.05mm [10'-0']
T
T
6"X6"(W5xW5 WWF)
NEW APRON
CONCRETE
T
NOTES:
BASE COURSE (GCA)
3.05m [10'-0"]
3.05m [10'-0"] OR
TO NEAREST JOINT
300mm [1'-0"]
T
T/4 ± 25mm [1"] BUT
NOT LESS THAN T/3
FOR 200mm [8"] OR
THINNER PAVEMENTS
NEW
CONCRETE
AIRFIELD PAVEMENT
SITE PAVEMENT
LOCATION
1.25 T OR 300mm
[1'-0"] MINIMUM
THICKENED EDGE
AS SHOWN ON CS401
m m m m m m
300mm [1'-0"] COMPACTED
SUBGRADE
SUBGRADE
NOTE:
SEE SPECIFICATIONS FOR SUBGRADE
PREPARATION.
1.
m m m m m m
40mm [1 1/2"]
EDGE DROP
(TYP)
300mm [1'-0"] COMPACTED
SUBGRADE
SUBGRADE
NOTE:
SEE SPECIFICATIONS FOR SUBGRADE
PREPARATION.
1.
DOWEL HOLES SHALL BE DRILLED AND
DOWELS EPOXIED INTO CURED
CONCRETE. DRILL HOLES SHALL BE
3.2mm [1/8"] LARGER THAN DOWEL
DIAMETER. NO HAND OPERATED
DRILLS ALLOWED. ONLY DRILLS ON
MOUNTED FRAMES SHALL BE USED TO
PREVENT MISALIGNMENT OF HOLES
200 [8"]
300 [12"]
6"X6"(W5xW5 WWF)
1. FOR SLABS DESIGNATED WITH "R"
2. FOR RAMP LOCATIONS, PROVIDE REINFORCMENT 100mm [4"]
BELOW TOP OF CONCRETE. MATCH SLOPE OF RAMP.
1. PLACE SCORE LINES AT INTERVALS EQUAL TO 1 TO 1 1/2 TIMES THE WIDTH OF THE SIDEWALK UNIFORMLY PLACED
ALONG LENGTH OF SIDEWALK.
2. USE 12mm [1/2"] EXPANSION JOINT FILLER WHERE WALK ABUTS CONCRETE CURBS, DRIVES, STRUCTURES AND
WHERE WALK CHANGES DIRECTION. INSTALL EXPANSION JOINTS AT 7.5m - 10m [25'-0" TO 30'-0"] INTERVALS ALONG
SIDEWALKS.
3. EDGE SIDEWALK WITH 12mm [1/2"] RADIUS EDGING TOOL. ROUND EDGES AT EXPANSION JOINTS TO A RADIUS OF
12mm [1/2"].
4. MEDIUM BROOM FINISH SHALL BE APPLIED PERPENDICULAR TO TRAFFIC FLOW.
5. FOR SIDEWALKS WIDER THAN 1.50m [5'-0"] PROVIDE LONGITUDINAL CONTRACTION JOINTS AT 1.50m TO 1.85m [5'-0" TO
6'-0"] MAXIMUM SPACING.
6. TYPE A JOINTS TO BE LOCATED TO MAINTAIN AN APPROXIMATE SQUARE SLAB AS INDICATED ON PLANS.
7. TYPE B JOINTS TO BE LOCATED WHERE WALK ABUTS CONCRETE CURBS, DRIVES, STRUCTURES AND WHERE WALK
CHANGES DIRECTION (MAXIMUM 7.60m [25'-0"] CENTERS).
m m
NOTES:
COMPACTED
SUBGRADE
REINFORCEMENT 150mm X
150mm [6" x 6"] - W3 x W3
WELDED WIRE MESH
SECTION
100mm [4"] CRUSHED
ROCK BASE
BROOM FINISH
100mm [4"] PCC
BUILDING
FLOOR
TYPE B JOINT - EXPANSION
PRE-FORMED EXP.
JOINT MATERIAL
SMOOTH
DOWEL
BAR
12mm
[1/2"] RAD
12mm [1/2"]
REINFORCEMENT
3mm [1/8"]
3mm
[1/8"] RAD
TYPE A JOINT - TOOLED
m m
M I N
REINFORCEMENT
NEW CONCRETE 9mm [0.362"]
DIA "VEE" LEG CHAIRS WELDED
AT ALL INTERSECTION TO TOP
AND BOTTOM SPACER BAR
4.5mm [0.177"] DIA SPREADER WIRES
WELDED TO TOP SPACER BARS 3 PER
ASSEMBLY TO BE CLIPPED AFTER STAKING
DOWELS WELDED ALTERNATELY
TO TOP SPACER BARS
9.20mm [0.362"] DIA TOP SPACER BARS
WELDED TO LEG CHAIRS - 2 PER ASSEMBLY
9.20mm [0.362"] DIA BOTTOM
SPACER WELDED TO LEG
CHAIRS - 2 PER ASSEMBLY
SCALE: NTSN1
DOWELED CONSTRUCTION JOINT - TYPE E
SCALE: NTSN2
DUMMY CONTRACTION
JOINT - TYPE D
SCALE: NTSN3
CONCRETE SLAB REINFORCED
SCALE: NTSH3
DOWELED BAR ASSEMBLY
SCALE: NTSK2
THICKENED EDGE EXPANSION JOINT - TYPE B
SCALE: NTSK4
ISOLATION JOINT AT FOUNDATION
OR STRUCTURE - TYPE A
SCALE: NTSH4
SIDEWALK PAVEMENT
SCALE: NTSD1
VEHICULAR SITE CONCRETE PAVEMENT
SCALE: NTSD2
AIRFIELD APRON CONCRETE PAVEMENT
AGGREGATE BASE COURSE (GCA)
PORTLAND CEMENT CONCRETE
GRADED, CRUSHED
T
3.05m [10'-0"]
THICKENED EDGE
AS SHOWN ON CS401
m m m m m m
300mm [1'-0"] COMPACTED
SUBGRADE
SUBGRADE
NOTE:
SEE SPECIFICATIONS FOR SUBGRADE
PREPARATION.
1.
SCALE: NTSD3
INTERIOR LO BAY AIRFIELD
CONCRETE PAVEMENT
T
T
APPROVED DOWEL
BAR ASSEMBLY FOR
TRANSVERSE JOINTS
GREASE ONE
END OF DOWEL
BAR CLEARANCE AT EDGE OF
PANEL SHALL BE A MINIMUM OF
0.6 TIMES THE LENGTH OF THE
BAR. SEE TABLE A, THIS SHEET
L
M I N
DOWEL
JOINT
0.6L
MIN.
THICKNESS
OF SLAB (T)
DIAM LENGTH SPACING
25mm[1"]200mm[8"]
300mm[12"]
405mm[16"] 300mm[12"]
380mm[15"]
DETAIL D1, CS501 FOR SITE
AND AIRFIELD PAVEMENT
DOWEL BAR SIZE
NOTES:
1. SEE SPECIFICATION SECTION 32 13 11 CONCRETE PAVEMENT FOR AIRFIELDS
AND OTHER HEAVY DUTY PAVEMENTS FOR ADDITIONAL DOWEL BAR SPACING
REQUIREMENTS.
2. WHEN DOWELED JOINTS ARE REQUIRED BETWEEN PAVEMENTS OF DIFFERING
THICKNESS, THE DOWELS SHALL BE SIZED FOR THE THINNER SECTION, AND
PLACED AT T/2 ± D/2 OF THE THINNER PAVEMENT.
L
S=DEPTH OF INITIAL SAWCUT SEE TABLE C, SHEET CS501
S
SCALE: NTSK1
DOWEL BAR LOCATION AND SIZES
SCALE: NTSK3
DOWELED CONTRACTION JOINT - TYPE C
TABLE A
31.75mm
[1.25"]
508mm
[20"]
DETAIL D3, CS501 FOR SITE
AND AIRFIELD PAVEMENT
T R
A F
F I C
F I L L E
T
FILLET
m m
LANE
TRAFFIC
EXISTING
FILLET
L A
N E
FILLET
DETAIL A DETAIL B DETAIL C
R. OF FILLET
THICKENED-EDGE
EXPANSION JOINT
DOWELED
CONTRACTION
JOINT
R. OF
FILLET
CONSTRUCTION OR
CONTRACTION JOINT
WITH TIE BARS
DOWELED
CONTRACTION
JOINT
DOWELED
CONTRACTION
JOINT
R. OF
FILLET
m m
SCALE: NTSH1
RIGID PAVEMENT FILLET DETAILS
DETAIL D3, CS501 FOR SITE
AND AIRFIELD PAVEMENT
DETAIL D2, CS501 FOR SITE
AND AIRFIELD PAVEMENT
DETAIL D1, CS501 FOR SITE
AND AIRFIELD PAVEMENT
900mm
[3']
3.05m [10'-0"]
THICKENED EDGE AS
SHOWN ON CS401
SAWCUT FULL DEPTH, REMOVE
EXISTING ASPHALT
SHOULDER
PAVEMENT
(TO REMAIN)
MIN
TACK COAT
PROPOSED
CONCRETE PAVEMENT
EDGE OF EXISTING
PAVEMENT,
DIMENSION OR
LOCATION
OF SAWCUT
INDICATED ON
PLANS
THICKENED EDGE
1.52m [5.00']
COMPACTED SUBGRADE
(SEE NOTE 1)
T
600mm
[2.00']
T
EXISTING
UNDERLYING
PAVEMENT
LIMITS OF REMOVAL
SHOWN ON PLANS
MATCH EXISTING
ASPHALT DEPTH
NOTE:
1. REMOVE EXISTING MATERIAL AND CONSTRUCT IN
ACCORDANCE WITH SPEC SECTION 31 23 13.
SCALE: NTSN4
NEW CONCRETE TO AC TRANSITION
SEE SPECIFICATION SECTION 31 20 00
CAPILLARY MOISTURE BARRIER -
date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
C O
P Y
R I G
B
U R
D
O N
N E
L L
E
N G
I N
E E
R I N
G
C
O M
P A
N Y
I N
C
C
DATEREV.
REVISIONS
DESCRIPTION INIT
HAWAII AIR NATIONAL GUARD
JOINT BASE PEARL HARBOR - HICKAM
OAHU, HAWAII
KANSAS CITY, MISSOURI
ENGINEERS ARCHITECTS & CONSULTANTS
88276
Project No. - KNMD189008
W9133L-15-D-0003
CONSTRUCT ADDITION TO
F-22 LO/CRF, B3408
FEBRUARY 2019
5 6
D
C
A
B
1 2 3 4
E
D
C
A
B
E
5 61 2 3 4
AP0
REVISED FINAL
SUBMITTAL (CODE CHECK)02/14/2019
KNMD159060CS500.DWG
0CS500
AutoCAD SHX Text
AutoCAD SHX Text
PAVEMENT DETAILS
1. THE FIRE SUPPRESSION SYSTEM SHALL BE SERVED
FROM THE EXISTING FIRE PUMPS IN B3406. CONTRACTOR
SHALL PERFORM PUMP TESTS, AND INCORPORATE THE
RESULTS INTO THE HYDRAULIC CALCULATIONS. TESTING
SHALL BE IN ACCORDANCE WITH NFPA 25, AND THE
RESULTS OF THE TESTING SHALL BE SUBMITTED IN
ACCORDANCE WITH SECTION 21 13 13.00 10.
FOR INFORMATION ONLY: B3406 FIRE PUMPS
QUANTITY 3
CAPACITY 1500 GPM (EACH)
RATED PRESSURE 120 PSI
2. EXISTING EQUIPMENT MAY BE REUSED IF FOUND TO BE IN
WORKING ORDER AND IT MEETS THE REQUIREMENTS OF THIS
CONTRACT. ALL EXISTING CONDITIONS ALONG WITH ALL NEW WORK
SHALL BE SHOWN IN THE DESIGN AND CALCULATIONS. FINAL TESTING
WILL NOT DIFFERENTIATE BETWEEN NEW AND EXISTING, ALL SHALL
BE TESTED AS NEW. THE CONTRACTOR SHOULD ASSUME THE
EXISTING CONDITIONS ARE DEFICIENT UNTIL FOUND TO BE
SATISFACTORY.
3. THE FIRE SUPPRESSION SYSTEM SHALL BE DESIGNED AND
INSTALLED BY A LICENSED / CERTIFIED COMPANY WHERE
EMPLOYEES ARE LICENSED / CERTIFIED TO INSTALL FIRE
PROTECTION EQUIPMENT IN THE STATE OF HAWAII.
4. ALL COMPONENTS AND ASSEMBLIES USED IN THIS FIRE
PROTECTION SYSTEM MUST BE SPECIFICALLY UL LISTED
OR FM APPROVED FOR THEIR INTENDED USE.
5. FIRE WATER AND FOAM SOLUTION PIPING USED ON THIS
PROJECT SHALL BE SCHEDULE 40 BLACK STEEL. FOAM
CONCENTRATE PIPING SHALL BE STAINLESS STEEL.
6. COMPLY WITH UFC 4-211-01 HEF DESIGN CRITERIA. SEE
SPECIFICATION SECTIONS 21 13 13.00 10 AND 21 13 25.00 10.
FOAM MUST COVER 90% OF THE AIRCRAFT SILHOUETTE
AREA IN ONE MINUTE OR LESS AFTER SYSTEM ACTIVATION.
FOAM MUST COVER THE ENTIRE HANGAR BAY TO A DEPTH
OF 3.2 FT IN FOUR MINUTES OR LESS AFTER SYSTEM
ACTIVATION.
1. UNDERGROUND FIRE WATER MAIN
A) PROVIDE PIPING ROUTED THROUGH THE FLOOR SLAB
WITH A SLEEVE.
2. FIRE PROTECTION EQUIPMENT ROOM
A) PROVIDE LABELS ON ALL PIPING (E.G. FIRE PROTECTION
WATER, FDC, BYPASS, TEST HEADER, FIRE SPRINKLER,
FOAM SYSTEM).
B) LOCATE ALL FOAM CONCENTRATE TANKS, PUMPING
EQUIPMENT, AND RISER CONTROL VALVES ASSOCIATED
WITH THE PROTECTION OF THE HANGAR BAY IN A
DEDICATED FIRE PROTECTION ROOM WITH A MINIMUM 1-
HOUR FIRE BARRIER.
C) PROVIDE A NEW FIRE PUMP TO SUPPORT HIGHER
PRESSURES FROM UPGRADED FOAM SYSTEM.
3. SUPPORT AREA WET-PIPE SPRINKLER RISERS – SUPPORT SPACE,
BAY 1 MECH SPACE, AND BAY 2 MECH SPACE
A) PROVIDE PIPING WITH FLEXIBLE COUPLINGS WITHIN 12
INCHES OF EACH SIDE OF A MASONRY WALL PENETRATION
OR 4 INCH ANNULAR SPACE DUE TO THE PROJECT
LOCATION BEING IN A SEISMIC ZONE.
4. HANGAR BAY WET-PIPE SPRINKLER RISER - HANGAR BAY 1 AND 2
A) PROVIDE HYDRAULIC NAMEPLATE INFORMATION.
5. HANGAR BAY WET-PIPE SPRINKLER SYSTEM
A) ADD SPRINKLERS SO THAT SPRINKLER COVERAGE IS
PROVIDED THROUGHOUT 100% OF THE AREA PROTECTED
BY THE RISER.
B) PROVIDE AUTOMATIC AIR VENT AT THE HIGH POINT(S) OF
THE SPRINKLER SYSTEM.
6. HANGAR BAY FOAM/WATER RISER - HANGAR BAY 1 AND 2
A) PROVIDE A REMOTE RESETTING FLOW CONTROL VALVE
WITH RECLOSING FEATURE, SPEED CONTROL SETTINGS,
AND FIELD ADJUSTABLE PRESSURE REDUCING TRIM.
B) PROVIDE HYDRAULIC NAMEPLATE INFORMATION.
7. HANGAR BAY FOAM SYSTEMS - HANGAR BAY 1 AND 2
A) MODIFY THE FOAM SYSTEMS AS REQUIRED TO MEET
UFC 4-211-01 PERFORMANCE CRITERIA.
8. FOAM CONCENTRATE STORAGE
A) PROVIDE A CLOSED CELL DOUBLE WALL POLYETHYLENE
CONCENTRATE STORAGE TANK COMPATIBLE WITH THE
REQUIRED CONCENTRATE.
B) PROVIDE A SINGLE FOAM INDUCTOR PER FOAM/WATER
RISER.
1. MODIFY THE EXISTING WET-PIPE SPRINKLER SYSTEMS AND HIGH
EXPANSION FOAM SYSTEMS FOR THE EXISTING HANGAR BAYS. AT
A MINIMUM PROVIDE COMPONENTS AS INDICATED ON THESE
DRAWINGS. CONTRACTOR SHALL PROVIDE ADDITIONAL
COMPONENTS AND MODIFICATIONS AS REQUIRED TO PROVIDE
A FULLY FUNCTIONING FIRE SUPPRESSION SYSTEM.
2. ALL SYSTEMS WHICH REQUIRE COORDINATION BETWEEN
TRADES SHALL BE TO THE SATISFACTION OF THE ENGINEER
AND AUTHORITY HAVING JURISDICTION. ANY DEFICIENCIES,
INCONSISTENCIES, OR POORLY COORDINATED INSTALLATIONS
SHALL BE CORRECTED BY THE CONTRACTOR AT NO ADDITIONAL
COST.
3. FINAL DESIGN REQUIREMENTS (DEVICE QUANTITY, SIZE, AND
LOCATIONS) ARE THE SOLE RESPONSIBILITY OF THE FIRE
SUPPRESSION CONTRACTOR. DRAWINGS INDICATE MINIMUM
REQUIREMENTS; THE FIRE SUPPRESSION CONTRACTOR WILL
BE RESPONSIBLE FOR VERIFYING AND COORDINATING FINAL
DESIGN REQUIREMENTS WITH THESE CONSTRUCTION
DOCUMENTS, SPECIFICATIONS, REFERENCE DOCUMENTS,
APPLICABLE CODES, AND FACILITY USER REQUIREMENTS.
4. INSTALL FIRE PROTECTION PIPE HANGERS PER THE FOLLOWING
LIMITATIONS:
A) THE EQUIPMENT DEAD LOAD APPLIED TO ANY
STRUCTURAL BAR JOIST SHALL NOT EXCEED 200 LBS.
THE EQUIPMENT DEAD LOAD APPLIED TO ANY
STRUCTURAL BEAM SHALL NOT EXCEED 300 LBS.
PROVIDE TRAPEZE HANGERS TO DISTRIBUTE THE
LOAD BETWEEN STRUCTURAL MEMBERS WHERE A
SINGLE HANGER EXCEEDS THE LIMITATIONS.
B) SWAY BRACES FOR PIPING LATERAL LOADS
SHALL NOT BE ATTACHED TO ROOF JOIST
BOTTOM CHORDS. BRACE LOADS (WORKING
STRESS) SHALL BE LIMITED TO THE FOLLOWING:
1. 500 LBS. WHEN ATTACHED TO JOIST
TOP CHORD.
5. ALL VALVES INCLUDING CONTROL AND TRIM VALVES SHALL BE
MAXIMUM 6 FT AFF.
6. ALL FIRE SUPPRESSION WATER AND FOAM / WATER PIPING
INSTALLED AS PART OF THIS PROJECT SHALL BE IN
ACCORDANCE WITH NFPA 13 PROTECTION OF PIPING DAMAGE
IN AREAS SUBJECT TO EARTHQUAKES. SHORT PERIOD
RESPONSE FACTOR Ss 0.566 PER STRUCTURAL SHEET S-001.
7. FOR WORK IN PAINT BAYS, ANY HARD SURFACES THAT REQUIRE
MODIFICATION SHALL BE CLEANED OF CHROMIUM AND SILVER BY
CONTRACTOR. CONTRACTOR SHALL DISPOSE OF USED CLEANING
MATERIALS VIA GOVERNMENT-PROVIDED USED MATERIALS DISPOSAL
AREA ON SITE. CONTRACTOR SHALL NOT TAKE USED MATERIALS OFF
SITE.
8. ALL EXPOSED FIRE ALARM JUNCTION BOXES, COVERS AND CONDUITS IN
UNFINISHED AREAS ARE TO BE PROVIDED PRE-FINISHED RED FROM THE
FACTORY. PAINT EXPOSED CONDUIT AND JUNCTION BOXES IN FINISHED
AREAS TO MATCH ADJACENT SURFACES. JUNCTION BOXES INSIDE COVER
LABELED, "FIRE ALARM". WHERE CONDUIT PENETRATES A WALL, RED 3/4
INCH WIDE BANDS SHALL BE PAINTED EVERY 20FT AND BOTH SIDES OF
PENETRATIONS PER UFC 3-600-01.
SECTION, DETAIL OR
ELEVATION IDENTIFICATION
MARK
PLATE NUMBER WHERE SECTION,
DETAIL OR ELEVATION IS TAKEN
SECTION, DETAIL OR ELEVATION TITLE
DETAIL NUMBER
PLATE NUMBER WHERE
DETAIL IS DRAWN
DETAIL CALLOUT SYMBOL
DETAIL/SECTION TITLE
AFF ABOVE FINISHED FLOOR
AHJ AUTHORITY HAVING JURISDICTION
FDC FIRE DEPARTMENT CONNECTION
FM FM GLOBAL
HEF HIGH EXPANSION FOAM
HSCP HORIZONTAL SPLIT CASE PUMP
(M) MECHANICALLY SUPERVISED
MSC MULTI-STAGE CENTRIFUGAL
NC NORMALLY CLOSED
(S) ELECTRICALLY SUPERVISED
SPR SPRINKLER PIPE
SQ FT SQUARE FOOT
TYP TYPICAL
UL UNDERWRITERS LABORATORIES
NEW WORK
EXISTING
TO REMAIN
CONSTRUCTION INTERFACE
PRESSURE RELIEF VALVE
OUTSIDE SCREW AND YOKE
VALVE (OS&Y)
VALVE
INDICATING BUTTERFLY VALVE
CHECK VALVE
BASKET STRAINER
FIRE DEPARTMENT
CONNECTION
PRESSURE GAUGE
PROPORTIONER
PRESSURE SWITCH
DELUGE VALVE
SOL
SOLENOID VALVE
FIRE SUPPRESSION LEGEND FIRE SUPPRESSION ABBREVIATIONS FIRE SUPPRESSION DESIGN CRITERIA FIRE SUPPRESSION GENERAL NOTES
DRAIN PIPING
PIPING SYMBOLS
AUTOMATIC AIR RELEASE
VALVE
FIRE SUPPRESSION SYSTEM
WET SYSTEM
SYSTEM PIPING
HAZARD CLASSIFICATION
NOTE 1: MODIFY THE EXISTING SYSTEM AS REQUIRED TO MEET DESIGN CRITERIA.
NOTE 2: PROVIDE AREA OF COVERAGE NEEDED IF ROOF SLOPE IS NOT 3:12.
HATCH SYSTEM
TYPE
WET/
HEF
REMOTE
AREA
SQ FT
HOSE
DEMAND
GPM
TEMPERATURE
RATING
SPRINKLER
TYPE
175º F QUICK RESPONSE WHITE
RECESSED PENDENT
NOTES
DENSITY
GPM/
SQ FT
0.20
MAXIMUM AREA
PER SPRINKLER
SQ FT
FIRE PROTECTION SPRINKLER SYSTEM DESIGN CRITERIA
HANGAR BAY
(UFC 4-211-01)
NO NEW SUPPRESSION
REQUIRED
FOAM SYSTEM
ANGLE VALVE
HEF GENERATOR
REDUCER
SURGE ARRESTER
EXISTING
TO REMAIN DEMOLITION
1,2
TEST HEADER
SYMBOL IDENTIFICATION LEGEND
EXISTING EQUIPMENT
NEW EQUIPMENT
DEMOLISH/REMOVE EQUIPMENT
SCOPE OF WORK
A1
FXxxx
PRESSURE RELIEF VALVE
PRESSURE REGULATING VALVE
UNDERGROUND FIRE WATER
FIRE PUMP SCHEDULE
PUMP
TYPE
FP-1
MARK
ELECTRICAL DATA
HSCP
DRIVE
TYPE
ELECTRIC
SERVICE
TYPE
FLOW
RATE
(GPM)
TOTAL
HEAD
(PSI) HP V/Ph/Hz
FIRE PUMP
JOCKEY PUMP
500 120 75 460/3/60
JP-1 MSC ELECTRIC 5 130 3 460/3/60
FIRE PUMP HOUSE
14" FW
F W
F W
LO HANGARS
F W
F W
F W
F W
FIRE DRAIN PUMP SCHEDULE
TYPE
PP-01
TAG NO.
VERTICAL
CENTRIFUGAL
SERVICE
FIRE WATER
CAPACITY
(GPH)
HEAD
(TDH)
DISCHARGE
SIZE (IN.) MOTOR - HP
150 10 3/8 1/50
ELECTRICAL
(V/PH/HZ)
115/1/60
RESERVOIR
CAPCITY
(GALLONS)
NOTE 1: PROVIDE WITH 6 FOOT, 3-CONDUCTOR CABLE WITH GROUNDED 3-PRONG PLUG, THERMAL OVERLOAD PROTECTOR, ABS SUMP PAN, AND CONTROL FLOAT.
(SEE DIVISION 23 FOR DETAILED REQUIREMENTS)
BASIS OF
DESIGN
LITTLE GIANT
MODEL VCL-14
date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
REV. DATE DESCRIPTION INIT
C O
P Y
R
IG
H T
O M
P A
N Y
C O
N T
R A
C T
IN
G
E N
T
IT
Y
TFI - F-22 SQUADRON
W9133L-15-D-0003-3M07
HAWAII AIR NATIONAL GUARD
KANSAS CITY, MISSOURI
REVISIONS
JOINT BASE PEARL HARBOR - HICKAM
OAHU, HAWAII
Project No. KNMD16-2546
ENGINEERS ARCHITECTS & CONSULTANTS
REPAIR FIRE
SUPPRESSION SYSTEM, B3408
D
C
A
B
E
D
C
A
B
E
5 61 2 3 4
5 61 2 3 4
/5
/2
:0
:2
P M
FX001
103072
FIRE SUPPRESSION NOTES, LEGEND AND
ABBREVIATIONS
05/18/18
A. DAHL C. CAHILL
A.HANKINS
0 08/20/18 B.3 SUBMITTAL AD
N.T.S.SCALE:A1
FIRE WATER SITE PLAN
GENERAL NOTES:
1. GENERAL:
A. THESE NOTES, AND OTHER DRAWING NOTES CONTAINED WITHIN, ARE PROVIDED
TO MEET SPECIFIC REQUIREMENTS AND TO SUPPLEMENT THE CONTRACT
SPECIFICATIONS. THESE NOTES NEITHER REPLACE NOR OVERRIDE THE
PROVISIONS AND REQUIREMENTS OF THE CONTRACT SPECIFICATIONS.
B. CONTRACTOR SHALL COORDINATE ALL STRUCTURAL WORK WITH WORK SHOWN
ON ALL OTHER DRAWINGS.
C. CONTRACTOR SHALL VERIFY ALL DIMENSIONS OF EXISTING CONSTRUCTION AND
REPORT ANY DISCREPANCIES FROM THE CONTRACT OR REFERENCE DRAWINGS
TO THE CONTRACTING OFFICER'S REPRESENTATIVE PRIOR
TO COMMENCING WITH WORK. SCALING OF WORKING DIMENSIONS FROM THE
STRUCTURAL DRAWINGS IS PROHIBITED.
D. CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED
STRUCTURE. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS
OF CONSTRUCTION INCLUDING, BUT NOT LIMITED TO, SHORING AND TEMPORARY
BRACING. CONTRACTOR SHALL UNDERTAKE ALL NECESSARY MEASURES TO ENSURE
SAFETY OF ALL PERSONS AND STRUCTURES AT THE SITE AND ADJACENT TO THE SITE.
VISITS TO THE SITE BY THE CONTRACTING OFFICER'S REPRESENTATIVE SHALL
NOT RELIEVE THE CONTRACTOR OF SUCH RESPONSIBILITY.
E. IF CERTAIN FEATURES ARE NOT FULLY SHOWN OR CALLED FOR ON THE CONTRACT
DRAWINGS OR SPECIFICATIONS, THEIR CONSTRUCTION SHALL BE OF THE SAME
CHARACTER AS FOR SIMILAR CONDITIONS THAT ARE SHOWN OR CALLED FOR, WITH
THE APPROVAL OF THE CONTRACTING OFFICER'S REPRESENTATIVE.
WHERE SECTIONS VARY, CONTRACTOR SHALL PROVIDE FOR SMOOTH TRANSITIONS
BETWEEN THEM, UNLESS NOTED OTHERWISE.
F. ALL PRODUCTS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS'
WRITTEN INSTRUCTIONS AND RECOMMENDATIONS, UNLESS NOTED OTHERWISE.
G. ELEVATION 100'-0" CORRESPONDS TO ELEVATION OF 9.17' AS SHOWN ON CIVIL DRAWINGS CG100.
2. DESIGN STANDARDS
A. PRINCIPAL CODE OF RECORD: INTERNATIONAL BUILDING CODE 2015.
B. ASCE 7, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, 2010.
C. ACI 318, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, 2014.
D. ACI 530/ASCE 5/TMS 402, BUILDING CODE REQUIREMENTS FOR MASONRY
STRUCTURES, 2013.
E. AISC 325, STEEL CONSTRUCTION MANUAL, 14th EDITION, 2011.
F. AISI COLD-FORMED STEEL DESIGN MANUAL, 2012.
5. GEOTECHNICAL INFORMATION
A. SOURCE: SUBSURFACE INFORMATION FOR F-22 LOCRF ADDITION, JOINT BASE
PEARL HARBOR-HICKHAM AIR FORCE BASE, OAHU, HAWAII. SEPTEMBER 2016.
B. SITE PREPARATION
1. EXCAVATION, FILL, AND BACKFILL SHALL BE IN ACCORDANCE WITH THE CONTRACT
DRAWINGS AND SPECIFICATIONS, DIVISION 31.
2. CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER WHEN
LOOSE OR SOFT SOILS ARE EXPOSED WHERE SLABS, MATS, OR FOOTINGS ARE
TO BE PLACED SO THAT A DETERMINATION MAY BE MADE REGARDING
IMPROVEMENT OF THIS POTENTIALLY UNDESIRABLE CONDITION.
3. CONTRACTOR TO PROVIDE TEMPORARY SUPPORT FOR THE EXIST FDN DURING
CONSTRUCTION OF THE NEW GRADE BEAMS. ADDITIONALLY, THE
CONTRACTOR SHALL PROVIDE SETTLEMENT AND LATERAL DEFLECTION MONITORING
POINTS ALONG THE EXIST FDN TO MONITOR ANY MOVEMENT OF THE EXIST STRUCTURE
DURING CONSTRUCTION.
C. SOIL CHARACTERISTICS
1. UNIT WEIGHT: 18.85 kN/m³ (120 PCF) DRY.
2. WATER TABLE DEPTH: 1.86M TO 1.987M (6.1 to 6.5 FEET) BELOW THE EXISTING
PAVEMENT DEPTH
D. LATERAL EARTH PRESSURE
1. AT-REST CONDITION, Ko: 8.64 kN/m³ (55 PCF), EQUIVALENT FLUID.
2. ACTIVE CONDITION, Ka: 5.81 kN/m³ (37 PCF), EQUIVALENT FLUID.
3. PASSIVE CONDITION, Kp: 51.84 kN/m³ (330 PCF), EQUIVALENT FLUID.
E. SLAB, MAT, AND FOOTING DESIGN PARAMETERS
1. MODULUS OF SUBGRADE REACTION: 250 PCI.
2. ALLOWABLE BEARING CAPACITIES (MINOR EQUIPMENT PADS)
a. GRAVITY LOADS: 120 KPa (2500 PSF).
3. FROST DEPTH: 0".
4. CONCRETE-SOIL COEFFICIENT OF FRICTION: 0.40.
5. MINIMUM STABILITY FACTORS OF SAFETY
a. OVERTURNING: 1.5.
b. UPLIFT: 1.5.
c. SLIDING: 1.5.
F. PILING
1. FOUNDATION PILING (MICROPILES) AND ASSOCIATED STATIC PILE LOAD TESTING
SHALL BE PROVIDED IN ACCORDANCE WITH THE CONTRACT SPECIFICATIONS,
SECTIONS 310916.23, 0310916.24 AND 316333.
2. MINIMUM PILE DESIGN CAPACITIES
a. COMPRESSION: 400 kN [90 KIPS] STRUCTURAL PLUS 45 kN [10 KIP] DRAG LOAD
(ALLOWABLE). 890 kN [200 KIPS] (ULTIMATE). LOAD TEST TO 1335 kN [300 KIPS].
b. UPLIFT: 267 kN [60 KIPS] (ALLOWABLE); 534 kN [120 KIPS] (ULTIMATE).
c. SHEAR: 58 kN [13 KIPS] (ALLOWABLE); 116 kN [26 KIPS] (ULTIMATE). LOAD TEST
TO 116 kN [26 KIPS].
3. SPECIAL INSPECTIONS
A. STATEMENT OF SPECIAL INSPECTIONS
1. SEE STATEMENT OF SPECIAL INSPECTIONS ON DRAWING S-003.
4. DESIGN LOADS
A. RISK CATEGORY: II PER ASCE 7-10.
B. LIVE LOADS PER ASCE 7-10
1. ROOF LIVE LOAD: 0.96 kPa [20 PSF].
2. CATWALK LIVE LOAD: 1.92 kPa [40 PSF].
C. COLLATERAL LOADS:
1. ROOF: 0.43 kPa [9 PSF]
2. CEILING: 0.57 kPa [12 PSF]
3. PV: 0.24 kPa [5 PSF]
D. EQUIPMENT LOADS
1. AS INDICATED FOR EQUIPMENT WEIGHING IN EXCESS OF 300 LBS. FRAMING AND
FOUNDATIONS ARE DESIGNED FOR EQUIPMENT WHICH SATISFIES THE CONTRACT
SPECIFICATIONS.
2. IF EQUIPMENT FURNISHED IS HEAVIER THAN THE WEIGHTS INDICATED, OR
REQUIRES STRUCTURAL CHANGES FOR ANY OTHER REASON, CONTRACTOR SHALL
PROVIDE ENGINEERING DESIGN CALCULATIONS AND ADDITIONAL STRUCTURAL
WORK NECESSARY TO SUPPORT ALL LOADS IN ACCORDANCE WITH THE DESIGN
STANDARDS SPECIFIED ABOVE, AT NO ADDITIONAL COST TO THE OWNER AND WITH
NO INCREASE IN CONTRACT TIME.
E. SNOW LOAD PER ASCE 7-10
1. GROUND SNOW LOAD: 0 kPa [0 PSF].
F. WIND LOAD PER ASCE 7-10
1. ULTIMATE DESIGN WIND SPEED: 209 km/h [130 MPH] 3-SECOND GUST.
2. NOMINAL DESIGN WIND SPEED: 163 km/h [101 MPH] 3-SECOND GUST.
3. RISK CATEGORY: II.
4. EXPOSURE CATEGORY: D.
5. BUILDING CONDITION: PARTIALLY ENCLOSED, GCpi = +/-0.55.
6. TOPOGRAPHIC FACTOR: 1.0.
7. DESIGN PRESSURES FOR COMPONENTS AND CLADDING ARE INDICATED ON
DRAWING S-004.
G. SEISMIC LOAD PER PER ASCE 7-10
1. MAXIMUM CONSIDERED EARTHQUAKE SPECTRAL RESPONSE
ACCELERATIONS Ss = 0.566, S1 = 0.162.
2. DESIGN EARTHQUAKE SPECTRAL RESPONSE ACCELERATIONS Sds = 0.593, Sd1 = 0.361.
3. RISK CATEGORY: II.
4. SITE CLASS: E.
5. SEISMIC DESIGN CATEGORY: D.
6. BASIC SEISMIC FORCE RESISTING SYSTEM:
a. HANGAR BAY: ORDINARY CONCENTRIC BRACED FRAMES (OCBF), R=3.25.
b. SHOPS: OCBF, R=3.25 & SPECIAL REINFORCED MASONRY SHEAR WALLS (SRMSW), R=5.
c. FIRE PROTECTION AND ELECTRICAL ROOM: (OCBF), R=3.25.
7. SEISMIC RESPONSE COEFFICIENT: Cs = 0.182 (OCBF) and 0.119 (SRMSW).
8. DESIGN BASE SHEAR: 87 KIPS - HANGAR (OCBF), 25.2 KIPS - SHOPS (OCBF) AND
16.4 KIPS SHOPS (SRWSW).
9. ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE.
6. MATERIALS: SEE THE CONTRACT SPECIFICATIONS FOR COMPLETE REQUIREMENTS
AND COMPLY WITH ALL APPLICABLE OSHA REGULATIONS
A. REINFORCED CONCRETE: SECTIONS 03 10 00, 03 15 50, 03 20 00 AND 03 30 00
1. REINFORCED CONCRETE SHALL BE PREPARED AND PLACED IN
ACCORDANCE WITH ACI MANUAL OF CONCRETE PRACTICE.
2. CONCRETE
a. UNLESS NOTED OTHERWISE: MINIMUM 28-DAY COMPRESSIVE STRENGTH f'c = 27.6 MPa [4000 PSI], NORMAL WEIGHT.
b. INTERIOR SLABS WITH TROWEL FINISH SHALL NOT HAVE AIR ENTRAINMENT.
3. FORMWORK
a. CONTRACTOR SHALL BE RESPONSIBLE FOR DESIGN, ENGINEERING, STRUCTURAL
ADEQUACY, AND CONSTRUCTION OF ALL CONCRETE FORMWORK IN ACCORDANCE
WITH THE CONTRACT SPECIFICATIONS.
b. COORDINATE ALL CONCRETE WORK WITH THE PLACEMENT OF PIPING, INSERTS, FLOOR DRAINS, AND OTHER EMBEDDED ITEMS INDICATED ON THE CONTRACT
DRAWINGS OR IN THE CONTRACT SPECIFICATIONS.
c. ALL NEW OR EXISTING PIPING OR UTILITIES PASSING THROUGH NEW CONCRETE
SHALL BE SLEEVED 13 [1/2"] CLEAR ALL AROUND, UNLESS NOTED
OTHERWISE. SEE OTHER DISCIPLINE DRAWINGS FOR SLEEVE DETAILS.
CONTRACTOR SHALL PROVIDE MEASURES TO ENSURE THAT SLEEVES REMAIN
FREE OF DEBRIS AND WATER DURING CONSTRUCTION.
d. PROVIDE 19 [3/4"] CHAMFER STRIPS ON ALL EDGES OF EXPOSED CONCRETE, UNLESS
NOTED OTHERWISE.
e. WITH THE EXPLICIT PRIOR APPROVAL IN WRITING OF THE CONTRACTING OFFICER'S
REPRESENTATIVE, COLUMN AND WALL FOOTINGS MAY BE EARTH-FORMED USING
UNDISTURBED NATIVE SOIL. PROVIDE A MINIMUM EXCAVATION WIDTH 102 [4"] GREATER
THAN INDICATED, AND A DEPTH 51 [2"] GREATER THAN INDICATED.
4. REINFORCING STEEL
a. BARS: ASTM A615 GRADE 60.
b. WELDED WIRE REINFORCEMENT: ASTM A1064.
c. ALL CONCRETE SHALL BE REINFORCED UNLESS SPECIFICALLY MARKED "NOT
REINFORCED" OR "UNREINFORCED".
d. CONTRACTOR SHALL DETAIL AND PLACE ALL REINFORCEMENT IN ACCORDANCE
WITH ACI SP-66, ACI 301, ACI 318, AND CRSI MANUAL OF STANDARD PRACTICE.
e. MINIMUM CONCRETE CLEAR COVER OVER REINFORCEMENT SHALL BE AS
FOLLOWS, UNLESS NOTED OTHERWISE:
(1) CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 76 [3"].
(2) CONCRETE EXPOSED TO EARTH OR WEATHER: #6 THROUGH #11 BARS - 76 [3"];
#5 AND SMALLER BARS, WELDED WIRE FABRIC - 76 [3"].
(3) CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND:
SLABS AND WALLS - 25 [1"]; BEAMS AND COLUMNS, PRIMARY REINFORCEMENT,
TIES, STIRRUPS, SPIRALS - 51 [2"].
f. EMBEDMENT AND LAP SPLICE LENGTHS FOR ALL REINFORCING STEEL BARS SHALL
CONFORM TO THE FOLLOWING PROVISIONS, UNLESS NOTED OTHERWISE.
(1) MINIMUM STRAIGHT EMBEDMENT LENGTHS:
(a) #10 - 305 [#3 - 12"] #19 - 457 [#6 - 18"] #29 - 914 [#9 - 36"]
(b) #13 - 305 [#4 - 12"] #22 - 635 [#7 - 25"] #32 - 1118 [#10 - 44"]
(c) #16 - 381 [#5 - 15"] #25 - 737 [#8 - 29"] #36 - 1346 [#11 - 53"]
(2) MINIMUM LAP SPLICE LENGTHS:
(a) #10 - 305 [#3 - 12"] #19 - 584 [#6 - 23"] #29 - 1168 [#9 - 46"]
(b) #13 - 381 [#4 - 15"] #22 - 838 [#7 - 33"] #32 - 1448 [#10 - 57"]
(c) #16 - 423 [#5 - 19"] #25 - 940 [#8 - 37"] #36 - 1727 [#11 - 68"]
(3) MINIMUM HOOK EMBEDMENT LENGTHS:
(a) #10 - 203 [#3 - 8"] #19 - 381 [#6 - 15"] #29 - 559 [#9 - 22"]
(b) #13 - 254 [#4 - 10"] #22 - 432 [#7 - 17"] #32 - 635 [#10 - 25"]
(c) #16 - 305 [#5 - 12"] #25 - 483 [#8 - 19"] #36 - 686 [#11 - 27"]
(4) HORIZONTAL BARS HAVING MORE THAN 12" OF CONCRETE PLACED BELOW
THEM SHALL BE CONSIDERED TOP REINFORCEMENT AND SHALL HAVE
MINIMUM STRAIGHT EMBEDMENT AND LAP SPLICE LENGTHS INCREASED BY
NOT LESS THAN 30% OVER THOSE GIVEN ABOVE.
(5) HOOK EMBEDMENT IS THE MINIMUM STRAIGHT LINE DISTANCE FROM THE
CRITICAL SECTION OF THE BAR TO THE FARTHEST EDGE OF THE HOOK.
(6) EPOXY-COATED BARS SHALL HAVE MINIMUM STRAIGHT EMBEDMENT, LAP
SPLICE, AND HOOK EMBEDMENT LENGTHS INCREASED BY NOT LESS THAN
20% OVER THOSE GIVEN ABOVE.
(7) EPOXY GROUT: CONFORM TO ASTM C881, TYPE IV, GRADE 3, EXCEPT GEL
TIMES. PROVIDE MINIMUM EMBEDMENT LENGTH REQUIRED TO DEVELOP
ULTIMATE STRENGTH OF BAR.
g. PROVIDE ADDITIONAL REINFORCEMENT AT ALL OPENINGS AND CORNER BARS AT
ALL INTERSECTING GRADE BEAMS, WALLS, AND CURBS IN ACCORDANCE WITH THE
STANDARD DETAILS ON DRAWING S-005, UNLESS NOTED OTHERWISE.
5. JOINTS
a. LOCATE ALL CONSTRUCTION, CONTRACTION, ISOLATION, EXPANSION, AND OTHER
JOINTS AS INDICATED OR SPECIFIED, OR OTHERWISE APPROVED BY THE
CONTRACTING OFFICER.
b. SURFACES OF ALL HORIZONTAL AND VERTICAL CONSTRUCTION JOINTS SHALL BE
CLEANED OF LAITANCE AND SHALL EXPOSE CLEAN COARSE AGGREGATE SOLIDLY
EMBEDDED IN MORTAR MIX. JUST PRIOR TO DEPOSITING CONCRETE, SURFACE OF
CONSTRUCTION JOINT SHALL BE THOROUGHLY CLEANED AND WETTED.
c. THESE PROVISIONS SHALL ALSO APPLY WHEN NEW CONCRETE IS PLACED AGAINST
EXISTING CONCRETE. IN ADDITION, EXISTING CONCRETE SURFACE SHALL BE
ADEQUATELY PREPARED BY APPLICATION OF A BONDING AGENT.
d. PROVIDE WATERSTOPS AT CONCRETE JOINTS WHERE INDICATED ON THE
CONTRACT DRAWINGS.
B. REINFORCED MASONRY: SECTION 04 20 00
1. SEE S-007.
C. STRUCTURAL STEEL: SECTIONS 05 12 00
1. STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH AISC STEEL
CONSTRUCTION MANUAL, 14th EDITION.
2. TEMPORARY ERECTION BRACING SHALL BE DESIGNED AND PROVIDED BY THE CONTRACTOR
AS REQUIRED AND SHALL NOT BE REMOVED UNTIL ALL PERMANENT LATERAL-LOAD-RESISTING
ELEMENTS AND CONNECTIONS ARE COMPLETELY INSTALLED.
3. WIDE FLANGE SHAPES AND TEES: ASTM A992, Fy = 344 MPa [50 KSI].
4. OTHER SHAPES, PLATES, AND THREADED RODS
a. ASTM A36, Fy = 248 MPa [36 KSI], UNLESS NOTED OTHERWISE.
b. ASTM A572 GRADE 50, Fy = 344 MPa [50 KSI], WHERE INDICATED AS "(50)".
5. SQUARE AND RECTANGULAR HOLLOW STRUCTURAL SECTIONS: ASTM A500 GRADE C,
Fy = 344 MPa [50 KSI].
6. ROUND HOLLOW STRUCTURAL SECTIONS: ASTM A500 GRADE C, 344 MPa [50 KSI].
7. PIPE: ASTM A53 TYPE E OR S, GRADE B, Fy = 241MPa [35 KSI].
8. BOLTS
a. 19 [3/4"] DIAMETER ASTM A325, UNLESS NOTED OTHERWISE.
b. FRAMING CONNECTIONS: PRETENSIONED JOINTS WITH STANDARD HOLES, UNLESS
NOTED OTHERWISE.
c. BRACING CONNECTIONS: SLIP-CRITICAL JOINTS WITH STANDARD HOLES, UNLESS
NOTED OTHERWISE.
d. SLIP-CRITICAL JOINTS SHALL HAVE CLASS A FAYING SURFACES.
e. ON ONE SIDE OF EACH DOUBLE CONNECTION OF BEAMS TO A COLUMN WEB OR A
GIRDER WEB DIRECTLY OVER A COLUMN, PROVIDE A TEMPORARY SEAT ANGLE
ATTACHED TO COLUMN OR GIRDER WEB AND TO BOTTOM FLANGE OF BEAM. MINIMUM
SEAT CONNECTION SHALL BE L4x3x3/8 LLH WITH TWO 19 [3/4"] DIAMETER A307 OR A325-ST
BOLTS EACH LEG. SINGLE AND DOUBLE STAGGERED CONNECTIONS ARE PROHIBITED
WITHOUT THE EXPLICIT PRIOR APPROVAL IN WRITING OF THE STRUCTURAL ENGINEER OF
RECORD.
9. WELDING: IN ACCORDANCE WITH AWS D1.1 USING E70 ELECTRODE WITH LOW HYDROGEN.
10. ALL DOUBLE ANGLE MEMBERS SHALL HAVE SPACER PLATES TO COMPLY WITH AISC
PARAGRAPH E6.2.
a. THICKNESS: TO MATCH END GUSSET PLATES.
b. MINIMUM ATTACHMENT: CONNECT TO HEEL AND TOE OF EACH ANGLE USING 5 x 25 [3/16" x 1"]
LONG FILLET WELDS.
11. HEADED STUDS
a. COLD-FINISHED STEEL CONFORMING TO ASTM A108, GRADE 1015 OR 1020.
b. ALL STUDS LOCATED SO AS TO OBSTRUCT WALKING SURFACES OF BEAMS OR JOISTS
SHALL BE FIELD INSTALLED.
12. ANCHOR BOLTS
a. ASTM F1554 GRADE 36 UNLESS NOTED OTHERWISE.
b. LOCATE ANCHOR BOLTS ACCURATELY, SET WITH TEMPLATES, AND SECURELY HOLD IN
POSITION WHILE PLACING IN CONCRETE. PROTECT IN-PLACE ANCHOR BOLTS FROM
CONSTRUCTION ACTIVITY.
c. THE FOLLOWING ARE PROHIBITED WITHOUT THE EXPLICIT PRIOR APPROVAL IN WRITING
OF THE STRUCTURAL ENGINEER OF RECORD:
(1) INSERTING ANCHOR BOLTS INTO FRESH OR PARTIALLY HARDENED CONCRETE.
(2) SUBSTITUTING POST-INSTALLED ANCHORS WHERE EMBEDDED ANCHOR BOLTS
ARE INDICATED.
(3) REPAIRING, REPLACING, OR MODIFYING INSTALLED ANCHOR BOLTS.
13. POST-INSTALLED ANCHORS: AS INDICATED.
14. GROUT: CEMENTITIOUS NONSHRINK.
D. STEEL DECK: SECTIONS 05 31 23
1. STEEL DECK, ATTACHMENTS, AND ACCESSORIES SHALL BE DESIGNED, FABRICATED,
AND INSTALLED IN ACCORDANCE WITH SDI MANUALS AND AISI COLD-FORMED STEEL
DESIGN MANUAL.
2. ROOF DECK
a. 1 1/2", 18 GAGE, WIDE RIB WITH
Fy = 33 KSI, Imin = 0.289 IN^4/FT, Smin = 0.318 IN^3/FT, GALVANIZED G90.
3. ALL STEEL ROOF DECK AND ROOF DECK ATTACHMENTS SHALL BE CAPABLE OF RESISTING
THE WIND UPLIFT LOADS INDICATED ON THE CONTRACT DRAWINGS AND A SERVICE
DIAPHRAGM SHEAR OF 1104 PLF.
4. ALL STEEL DECK SHALL CROSS A MINIMUM OF TWO SPANS. MINIMUM LENGTH OF END
LAPS FOR ROOF DECK AND BEARING AT ALL SUPPORTS SHALL BE 2".
5. ALL STEEL DECK SHALL BE SUPPORTED AT EDGES OF OPENINGS AND AROUND
COLUMNS. ADDITIONAL SUPPORT STEEL SHALL BE PROVIDED BY CONTRACTOR AS
REQUIRED AND FABRICATED SO THAT DECK RUNS CONTINOUSLY OVER MINOR
OPENINGS, WHICH SHALL NOT BE CUT UNTIL NEEDED BY OTHER TRADES.
6. MINIMUM STEEL DECK ATTACHMENT SHALL BE AS FOLLOWS:
a. DECK SHALL BE FASTENED AT EACH END AND AT INTERMEDIATE SUPPORTS
BY 5/8" DIAMETER PUDDLE WELDS, IN A 36/7 WELD PATTERN.
b. SIDE LAP CONNECTIONS SHALL BE MADE AT SEAMS USING #10 SCREWS, 9 PER SPAN.
c. CONNECTIONS ALONG SIDE BOUNDARIES, RIDGE PLATES, AND ROOF SUB
FRAMING SHALL BE MADE AT 12" ON CENTER MAXIMUM.
d. PNEUMATIC FASTENERS AND/OR SCREWS SHALL NOT BE SUBSTITUTED WHERE
WELDS ARE SPECIFIED, BUT MAY BE USED IN TEMPORARY ATTACHMENT OF
STEEL DECK.
7. NOTHING SHALL BE SUSPENDED DIRECTLY FROM THE ROOF DECK UNLESS APPROVED IN
WRITING BY THE STRUCTURAL ENGINEER OF RECORD.
E. COLD-FORMED STEEL FRAMING: SECTION 05 40 00
1. COLD-FORMED STEEL FRAMING SHALL BE DESIGNED, FABRICATED, AND ERECTED IN
ACCORDANCE WITH AISI COLD-FORMED STEEL DESIGN MANUAL AND SSMA OR LGSI
PUBLICATIONS AS APPLICABLE.
2. SHAPE DESIGNATIONS FOR STUDS, JOISTS, TRACK, CHANNELS, AND FURRING CHANNELS:
PER SSMA PRODUCT TECHNICAL INFORMATION, INDICATING MEMBER DEPTH, STYLE,
FLANGE WIDTH, AND MATERIAL THICKNESS.
3. FRAMING MEMBERS
a. ASTM A653 GRADE 33, Fy = 228 MPa [33 KSI], UNLESS NOTED OTHERWISE.
b. ASTM A653 GRADE 50, Fy = 344 MPa [50 KSI], FOR MATERIAL THICKNESS 54 MILS OR
GREATER AND WHERE INDICATED AS "(50)".
4. FINISH
a. HOT-DIP GALVANIZE TO PROVIDE A COATING CLASS OF G90.
5. MECHANICAL FASTENERS: CORROSION-RESISTANT-COATED, SELF-DRILLING, SELF-
THREADING STEEL DRILL SCREWS WITH LOW PROFILE HEADS BENEATH SHEATHING AND
MANUFACTURER'S STANDARD HEADS ELSEWHERE.
6. BOLTS: ASTM A325, GALVANIZED.
7. WELDING: IN ACCORDANCE WITH AWS D1.1 OR D1.3, AS APPLICABLE.
F. STEEL BAR GRATING:
1. STEEL BAR GRATING SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH
NAAMM MANUALS.
2. MATERIAL: ASTM A1011, GALVANIZED.
3. CONSTRUCTION: WELDED.
4. MAIN BEARING BARS: 3/16" x 1" AT 1 3/16" CENTERS.
5. CROSS BARS: AT 4" CENTERS.
6. SURFACE: PLAIN.
7. FABRICATE GRATING IN SECTIONS NOT GREATER THAN 5 FT WIDE.
date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
REV. DATE DESCRIPTION INIT
C O
P Y
R
IG
H T
Y
E
M
P A
N Y
C O
N T
R A
C T
IN
G
E N
T
IT
Y
W9133L-15-D-0003
HAWAII AIR NATIONAL GUARD
KANSAS CITY, MISSOURI
REVISIONS
JOINT BASE PEARL HARBOR - HICKAM
OAHU, HAWAII
Project No. KNMD189008
ENGINEERS ARCHITECTS & CONSULTANTS
CONSTRUCTION ADDITION TO
F-22 LO/CRF, B3408
D
C
A
B
E
D
C
A
B
E
5 61 2 3 4
5 61 2 3 4
/5
/2
:0 :4
P
M
88276_S_Central.rvt
S-001
88276
GENERAL NOTES
FEBRUARY 2019
M. VERBEEK W. BAILEY
B. DOWNEY
0 02/14/2019 REVISED FINAL SUBMITTAL
(CODE CHECK)
AP
1 08/06/2019 ADDENDUM 1 AP
PILE CAP
TOP OF COMPETENT
CORAL AND/OR
SANDSTONE AND
LIMESTONE
CENTRALIZER AT
MID-POINT OF BAR
CENTRALIZER
TYPE II MICROPILE 400kN
[90 KIP] CAPACITY
400kN [90 KIPS]COMPRESSION
LATERAL
UPLIFT 267kN [60 KIPS]
CENTRALIZER
PILE CUT -OFF
EL PER SCHEDULE
245 [9 5/8"] DIA STEEL PIPE (GR 80)
14 [0.545"] MIN WALL THICKNESS
(INSTALLED IN SEGMENTS AS REQD)
216 [8 1/2"] MIN DIA
BORED HOLE
#43 [#14] (GR 75) DYWIDAG BAR
(COUPLE AS REQD) FULL LENGTH.
SEE NOTE 9.
27.58 MPa [4000 PSI] GROUT
SEE SPECIFCATIONS
CENTER LINE
MICROPILE
SEE NOTE 8
T/CAP PER SCHEDULE
REINFORCEMENT
PER SCHEDULE
[5 '-0 m m , M
IN
[2 7'
-0 m m
, M
IN
[1 8'
-0
S E
E N
O T
E m m
, M
IN
P
IL
E L
E N
G T
H V
A R
IE
S
[3 '-0
[2 2'
-0
(D E
P T
H V
A R
IE
S
O V
E R
B U
R D
E N
M A
T E
R
IA
L -6
6m m
400kN [90 KIP] 245 [9 5/8 INCH] DIAMETER MICROPILE
[8
PILE CAP
CENTER LINE
MICROPILE
MICROPILE
REINFORCEMENT
T/CAP PER SCHEDULE
REINFORCEMENT
AS INDICATED
[1 '-0
[8
[2
CENTER LINE
MICROPILE
MICROPILE
REINFORCEMENT
PILE CAP
T/CAP PER
SCHEDULE
REINFORCEMENT
AS INDICATED
UPLIFT PLATE:
PL19x2134x178 #22 [PL3/4x7x0'-7" #14] (GR 75)
DYWIDAG BAR W/ HEX NUT ON
TOP AND LOCK NUT ON BOT
[1 '-1
0"
[8
[2
1. PROVIDE STEEL MICROPILE CASING WITH MIN 245mm [9.625"] OUTSIDE DIA, MIN 14mm [0.545"] WALL THICKNESS, AND MIN Fy=551MPa [80 KSI] IN ACCORDANCE WITH SPECIFICATIONS
SECTION 31 63 33.
2. PROVIDE ROCK SOCKET WITH MIN 216 [8.50"] DIA AND #43 [#14] (GRADE 75) CENTER BAR IN
ACCORDANCE WITH SPECIFICATIONS SECTION 31 63 33.
3. PROVIDE GROUT WITH MIN COMPRESSIVE STRENGTH OF 27.58MPa [4,000 PSI] IN
ACCORDANCE WITH SPECIFICATIONS SECTION 31 63 33.
4. PERFORM LATERAL PILE TEST PER SPECIFICATION SECTION 310916.24. PERFORM AXIAL
COMPRESSION PILE TEST PER SPECIFICATION SECTION 310916.23.
5. VERIFY ALL TOP OF PILE ELEVATIONS AND COORDINATE WITH FOUNDATION PLANS,
SECTIONS, DETAILS, AND SCHEDULES.
6. ESTIMATED PILE LENGTHS ARE APPROXIMATE. ACTUAL PILE TIP ELEVATIONS AND LENGTHS
WILL VARY ACCORDING TO SUBSURFACE CONDITIONS ENCOUNTERED.
7. FIELD CASING JOINTS SHALL NOT BE ALLOWED WITHIN 1524 [5'-0"] OF PILE CUT-OFF.
8. LATERAL CAPACITY OF MICROPILE CASING WITH 245 [9.625"] OUTSIDE DIA ARE AS FOLLOWS:
- FOR MPH-1 AND MPH-2: LATERAL CAPACITY = 57.8 kN [13 KIPS]
9. FOR TEST MICROPILES REINFORCEMENT SHALL BE #43 [#14] DYWIDAG BAR. SEE
SPECIFICATIONS FOR ADDITIONAL INFORMATION.
10. * FOR MICROPILE HEAD DETAIL INCLUDING EMBEDMENT AND UPLIFT PLATE
REQUIREMENTS SEE PILE CAP SCHEDULE ON S-600 AND MICROPILE DETAILS THIS SHEET.
MICROPILES NOTES:
date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
REV. DATE DESCRIPTION INIT
C O
P Y
R
IG
H T
Y
E
M
P A
N Y
C O
N T
R A
C T
IN
G
E N
T
IT
Y
W9133L-15-D-0003
HAWAII AIR NATIONAL GUARD
KANSAS CITY, MISSOURI
REVISIONS
JOINT BASE PEARL HARBOR - HICKAM
OAHU, HAWAII
Project No. KNMD189008
ENGINEERS ARCHITECTS & CONSULTANTS
CONSTRUCTION ADDITION TO
F-22 LO/CRF, B3408
D
C
A
B
E
D
C
A
B
E
5 61 2 3 4
5 61 2 3 4
/5
/2
:0 :5
P
M
88276_S_Central.rvt
S-500
88276
FOUNDATION DETAILS
FEBRUARY 2019
M. VERBEEK W. BAILEY
B. DOWNEY
NTSSCALE:C1
TYPICAL SECTION MICROPILE
NTSSCALE:C3
MICROPILE HEAD DETAIL - MPH-1
NTSSCALE:C4
MICROPILE HEAD DETAIL - MPH-2
0 02/14/2019 REVISED FINAL SUBMITTAL
(CODE CHECK)
AP
1 08/06/2019 ADDENDUM 1 AP
5/16
5/16
[1'-4"]
[1 '-8
[2
[1 '-4
[2
[2"]
[1'-0"]
[2"]
PL 19 [3/4"]
[2"]
[10"]
[10"]