Generators
| FORT JACKSON REAL PROPERTY GENERATORS | ||||||||||||||||
| Building Number | Serviced By | Specific Location | Building Function | Engine Manufacturer | Engine Model Number | Engine Serial Number | Genset Manufacturer | Genset Model Number | Genset Serial Number | Fuel | Generator Output (kW) | Engine HP | Manufacture Date | Stack configuration | ||
| (vertical, horizontal) | Associated Fuel Storage Tank | |||||||||||||||
| (AST, UST or None) | Capacity | |||||||||||||||
| (gallons) | Needed Service | |||||||||||||||
| 2400 | DPW | Behind building | Headquarters | Cummins | TD400-01 | P-8376 | Diesel | 400 | 536 | Jun-15 | In addition to regular maintenance, the following services need to occur: |
a. Oil and filter every 500 hours or annually
b. Inspect air cleaner every 1000 hours or annually. Change as needed
c. Inspect all hoses and belts every 500 hours or annually. Change as needed.
d. Document maintenance and include meter reading at the time of maintenance. Submit documentation to Fort Jackson 2609 DPW Behind building, inside fence NEC Mitsubishi 4D34-T(?) Unknown Generac 3931290100 2076879 Diesel 60 80 Apr-04 Vertical AST Unknown In addition to regular maintenance, the following services need to occur:
a. Oil and filter every 500 hours or annually
b. Inspect air cleaner every 1000 hours or annually. Change as needed
c. Inspect all hoses and belts every 500 hours or annually. Change as needed.
d. Document maintenance and include meter reading at the time of maintenance. Submit documentation to Fort Jackson 3100 DPW Next to building, inside fence NEC Cummins Unknown Unknown Cummins DSFAE-7295859 F110221737 Diesel 80 107 Jun-11 Vertical AST Unknown In addition to regular maintenance, the following services need to occur:
a. Oil and filter every 500 hours or annually
b. Inspect air cleaner every 1000 hours or annually. Change as needed
c. Inspect all hoses and belts every 500 hours or annually. Change as needed.
d. Document maintenance and include meter reading at the time of maintenance. Submit documentation to Fort Jackson J4236 DPW Next to building, inside fence NEC Mitsubishi 4D34-T 0D5825 Generac 3617980100 2074860 Diesel 80 107 Nov-03 In addition to regular maintenance, the following services need to occur:
a. Oil and filter every 500 hours or annually
b. Inspect air cleaner every 1000 hours or annually. Change as needed
c. Inspect all hoses and belts every 500 hours or annually. Change as needed.
d. Document maintenance and include meter reading at the time of maintenance. Submit documentation to Fort Jackson 4282 DPW Behind building NEC Cummins Q5X15-G9 79635574 Cummins DFEH-1220445 A130452520 Diesel 354 475? Jan-13 In addition to regular maintenance, the following services need to occur:
a. Oil and filter every 500 hours or annually
b. Inspect air cleaner every 1000 hours or annually. Change as needed
c. Inspect all hoses and belts every 500 hours or annually. Change as needed.
d. Document maintenance and include meter reading at the time of maintenance. Submit documentation to Fort Jackson 5499 DPW N/A EMS/Fire Department Cummins GTA855C1 25273798 Elliot Power Systems 180RN BX01J193 Natural Gas 180 293 Nov-01 Vertical None N/A In addition to regular maintenance, the following services need to occur:
a. Oil and filter every 500 hours or annually
b. Inspect spark plugs every 1000 hours or annually. Change as needed
c. Inspect all hoses and belts every 500 hours or annually. Change as needed.
d. Document maintenance and include meter reading at the time of maintenance. Submit documentation to Fort Jackson 5615 DPW Behind building, inside fence NEC Cummins QSM11-G4NR3 2003245 Cummins DQHAB-8086897 J110256725 Diesel 300 402 Sep-11 Vertical AST 600 In addition to regular maintenance, the following services need to occur:
a. Oil and filter every 500 hours or annually
b. Inspect air cleaner every 1000 hours or annually. Change as needed
c. Inspect all hoses and belts every 500 hours or annually. Change as needed.
d. Document maintenance and include meter reading at the time of maintenance. Submit documentation to Fort Jackson 12020 DPW N/A NEC Cummins Unknown Unknown Cummins DSFAE-7295845 F110221739 Diesel 80 107 Jun-11 Vertical AST Unknown In addition to regular maintenance, the following services need to occur:
a. Oil and filter every 500 hours or annually
b. Inspect air cleaner every 1000 hours or annually. Change as needed
c. Inspect all hoses and belts every 500 hours or annually. Change as needed.
d. Document maintenance and include meter reading at the time of maintenance. Submit documentation to Fort Jackson JRR DPW Johnson Rifle Road NEC Unknown Unknown Generac 14861230100 2118091 Diesel 50 67 Dec-16 Vertical AST Unknown In addition to regular maintenance, the following services need to occur:
a. Oil and filter every 500 hours or annually
b. Inspect air cleaner every 1000 hours or annually. Change as needed
c. Inspect all hoses and belts every 500 hours or annually. Change as needed.
d. Document maintenance and include meter reading at the time of maintenance. Submit documentation to Fort Jackson 7533 DPW N/A Emergency Operations Center (EOC) MTU 6R1600G70S 16301001230 MTU/Marathon Electric 433PSL6216 MX159004 PH Diesel 275 369 2010 In addition to regular maintenance, the following services need to occur:
a. Oil and filter every 500 hours or annually
b. Inspect air cleaner every 1000 hours or annually. Change as needed
c. Inspect all hoses and belts every 500 hours or annually. Change as needed.
d. Document maintenance and include meter reading at the time of maintenance. Submit documentation to Fort Jackson
| 4500 | MACH | Rm. 1-112D | Hospital | Waukesha | L6670DSTU | 363969 | Kato Engineering | 1000-693361111 | 88612 | Diesel | 1,000 | 1,341 | ~1982 | Vertical | UST | 20,000 | Hospital Maintains |
| 4500 | MACH | Rm. 1-112B | Hospital | GM Power | 12-645-E1 | 69-E1-1773 | Electric Machinery Manufacturing Co. | BEMACII | 168199511 | Diesel | 1,000 | 1,341 | ~1969 | Vertical | UST | 20,000 | Hospital Maintains |
| 4500 | MACH | Outside west of bldg | Hospital | Mitsubishi | S12H-Y2PTAW-1 | 31530 | Katolight | D1000FRY4T235128 | 142023-0907 | Diesel | 1,000 | 1,528 | Jun-07 | Vertical | AST | 3,400 | Hospital Maintains |
USTs
| FORT JACKSON UNDERGROUND STORAGE TANKS | ||||||
| USTs | Bldg No | No. | Type | Capacity (gal) | Permit No. | Services needed. |
| Gate 1 Shoppette | 2420 | 1 | Gasoline (Reg) | 12000 | 18458 | 1. Regular maintenance and repair as needed. |
2. Annual line and tank tightness testing.
3. Veeder Root leak detector tests
4. Overfill protection system tests.
5. All sensors inspected and checked.
| Gate 1 Shoppette | 2420 | 2 | Gasoline (Reg) | 12000 | 18458 | |
| Gate 1 Shoppette | 2420 | 3 | Gasoline (Prem) | 12000 | 18458 | |
| Gate 1 Veeder Roort System 450 Plus | ||||||
| Gate 2 Shoppette | 4120 | 1 | Gasoline (Reg) | 12000 | 13033 | 1. Regular maintenance and repair as needed. |
2. Annual line and tank tightness testing.
3. Veeder Root leak detector tests
4. Overfill protection system tests.
5. All sensors inspected and checked.
| Gate 2 Shoppette | 4120 | 2 | Gasoline (Reg) | 12000 | 13033 | |
| Gate 2 Shoppette | 4120 | 3 | Gasoline (Reg) | 12000 | 13033 | |
| Gate 2 Shoppette | 4120 | 4 | Gasoline (Prem) | 12000 | 13033 | |
| Gate 2 Veeder Roort System 450 Plus | ||||||
| Moncrief Hospital | 4500 | Diesel | 20000 | 16333 | Regular maintenance is performed by the hospital. |
Need to perform cathodic protection testing in 2017.
| Hospital Maintains | ||||||
| Energy Plant 1 | 2288 | 1 | No. 6 Fuel Oil | 50000 | N/A | May be removed |
| Energy Plant 1 | 2288 | 2 | No. 6 Fuel Oil | 50000 | N/A | May be removed |
| Energy Plant 1 | 2288 | 3 | No. 6 Fuel Oil | 50000 | N/A | May be removed |
| Energy Plant 1 | 2288 | 4 | No. 6 Fuel Oil | 50000 | N/A | May be removed |
| Energy Plant 2 | 4333 | 1 | No. 6 Fuel Oil | 50000 | N/A | May be removed |
| Energy Plant 2 | 4333 | 2 | No. 6 Fuel Oil | 50000 | N/A | May be removed |
| Energy Plant 2 | 4333 | 3 | No. 6 Fuel Oil | 50000 | N/A | May be removed |
| Energy Plant 2 | 4333 | 4 | No. 6 Fuel Oil | 50000 | N/A | May be removed |
| Energy Plant 2 | 4333 | 5 | No. 6 Fuel Oil | 50000 | N/A | May be removed |
| Energy Plant 2 | 4333 | 6 | No. 6 Fuel Oil | 50000 | N/A | May be removed |
| Energy Plant 2 | 4333 | 7 | No. 6 Fuel Oil | 50000 | N/A | May be removed |
| Energy Plant 2 | 4333 | 8 | No. 6 Fuel Oil | 50000 | N/A | May be removed |
ASTs
| FORT JACKSON ABOVEGROUND STORAGE TANKS | |||||
| Bldg No | No. | Type | Capacity (gal) | Description | Notes |
| 4282 | Diesel | 3000 | NEC | Needs painting, labeling and integrity testing. | |
| 4500 | Diesel | 500 | Hospital Basement | Maintained by the hospital | |
| 4500 | Diesel | 500 | Hospital Basement | Maintained by the hospital | |
| K5520 | Diesel | Ammo Supply Point | Needs painting, labeling and integrity testing. | ||
| N7651 | Diesel | 1000 | Wanat Range | Needs painting, labeling and integrity testing. |
OWS
| FORT JACKSON OIL WATER SEPERATORS | |||||||||||||
| Building | Organization | Sediment Trap/ Grit Chamber | Location | Type | Configuration | Construction Material | Accessibility (Top Of Tank) | OWS Size | Holding capacity | Alarm | Effluent Discharge To: | Recommend Cleaning Frequency | Recommend Cleaning |
| 2604 | TACOM Motor Pool | NO | OWS west of building | Standard Gravity | Cylindrical | Steel | Closed w/ manholes (Bolted) | ***** | ***** | Yes | Sanitary sewer POTW | Annually | OWS |
| 2607 | DPW Bus Wash | YES | OWS located immediately west of bus wash rack building. (location also has Grit Chamber located west of bus wash) | Coalescing Standard Gravity-Parallel plates/ Corrugated Plates | Cylindrical | Steel | Closed w/ manholes (Bolted) | 350 gallons | 140 gallons | Yes | Sanitary sewer POTW | Annually | OWS & Grit Chamber |
| 2610 | DPW/ LRC maintenance Complex | NO | OWS located next to wash rack | Coalescing Standard Gravity-Parallel plates/ Corrugated Plates | Cylindrical | Steel | Closed w/ manholes (Bolted) | 2000 gallons | 800 gallons (Integral) | Yes | Sanitary sewer POTW | Annually | OWS |
| 5669 | FMWR Autocraft Shop | NO | OWS at west end of building | Standard Gravity | Rectangular | Reinforce Concrete | Closed w/ manhole | 1000 gallons | ? | No | Sanitary sewer POTW | Annually | OWS |
| 5672 | Car Wash | NO | Not yet installed | Expected to be Standard Gravity | Expected to be Rectangular | Reinforced Concrete | Closed w/ manhole | Approx 1500 gal | ? | Yes | Sanitary sewer POTW | Semiannual | OWS |
| 9408 | AMC/ Tacom Motor Pool | NO | OWS south of wash rack | Coalescing Standard Gravity-Parallel plates/ Corrugated Plates | Cylindrical | Steel | Closed w/ manholes (Bolted) | 2000 gallons | 800 gallons (Integral) | No | Sanitary sewer POTW | Annually | OWS |
&"Arial Narrow,Bold"&24&K03+000 Fort Jackson OWS and Washrack Inventory
Washracks
| FORT JACKSON WASH RACKS | ||||||
| Building | Organization | Sediment Trap/ Grit Chamber | Location | Effluent Discharge To: | Recommend Cleaning Frequency | Recommend Cleaning |
| 2607 (Bus wash) | DPW Bus Wash | YES | Location also has Grit Chamber located west of bus wash) | Sanitary sewer POTW | Annually | Washrack |
| 2610 (Washrack) | DPW/ LRC maintenance Complex | Yes | OWS located next to wash rack | Sanitary sewer POTW | Annually | Washrack |
| 9408 (Washrack) | AMC/ Tacom Motor Pool | NO | OWS south of wash rack | Sanitary sewer POTW | Annually | Washrack |
&"Arial Narrow,Bold"&24&K03+000 Fort Jackson OWS and Washrack Inventory
Crane
| FJ Overhead Cranes | |||||||
| Building | Hoist Manufacturer | Crane Manufacturer | Crane Type | Rated Capacity | Span | Lift | Voltage |
| 2604 | Yale | RJ Mack | UHSG | 7.5 ton | 54 ft | 20 ft | 460 |
| 2602 | Yale | RJ Mack | UHSG | 7.5 ton | 54 ft | 20 ft | 460 |
| 2602 | R&M | Cleveland Tamrail | UHSG | 2 ton | 18 | 15 | 230 |
| 2603 | Yale | RJ Mack | UHSG | 7.5 ton | 54 ft | 20 ft | 460 |
| 2603 | Yale | RJ Mack | UHSG | 7.5 ton | 54 ft | 20 ft | 460 |