W912HN-21-B-3007_DRAWINGS_VOL2_AMD3.pdf
PDF 5 MB Posted
- Attached to
- Repair TBUP Building 399 Phase 2
- Solicitation number
- W912HN21B3007
About this file
This document package includes drawings and specifications for repair work on Building 399 at Fort Benning, Georgia under Solicitation Number W912HN21B3007 from the U.S. Army Corps of Engineers Savannah District. The repairs include repointing and repairing masonry, stucco cleaning and patching, roof system coordination, blocking and fixtures, gutter and downspout reinstallation, lightning protection system reinstallation, and verification of existing conditions and dimensions. The specifications provide details on materials and methods for exterior wall repairs, mortar joint repairs, limestone repairs, control joint resealing and other finish work. Repairs are also required for the failed and failing building systems including exterior walls, windows, fire protection, interior walls, doors, interior finishes, floors, ceilings, plumbing, HVAC, building controls, electrical, communications, and site utilities. Demolition and asbestos abatement are included to allow for the repairs. The solicitation is for a 100% competitive full and open acquisition under NAICS 236220 with price evaluation preference for HUBZone small businesses.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A. CONTRACTOR TO FIELD VERIFY ALL DIMENSION AND EXISTING
CONDITIONS PRIOR TO START OF CONSTRUCTION. IF ANY DISCREPANCIES
WITH CONSTRUCTION DOCUMENTS, CONTRACTOR IS TO INFORM
CONTRACTING OFFICER IN WRITING PRIOR TO START OF CONSTRUCTION.
B. CONTRACTOR IS TO PROTECT ALL EXISTING ITEMS TO REMAIN FROM
DAMAGE DURING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR
REPAIRING, AND/ OR REPLACING DAMAGED ITEMS TO REMAIN WITH
EQUAL OR BETTER, TO THEIR ORIGINAL STATE, AT NO COST TO
GOVERNMENT.
C. REPOINT LOOSE MORTAR JOINTS, REPAIR CRACKS AND DAMAGE AT ALL
EXISTING MASONRY WALLS. ALL EXTERIOR MASONRY REPAIRS SHALL
MATCH HISTORIC CHARACTER, COLOR, AND PATTERN OF EXISTING
FACADE. ALL WORK TO BE AS PER HISTORIC PRESERVATION
REQUIREMENTS. FINAL SELECTIONS TO BE APPROVED BY CONTRACTING
OFFICER.
D. CLEAN AND PATCH ALL EXISTING STUCCO. REPAIR CRACKS AND DAMAGE.
ALL EXTERIOR STUCCO REPAIRS SHALL MATCH HISTORIC CHARACTER,
COLOR, AND PATTERN OF EXISTING FACADE. ALL WORK TO BE AS PER
HISTORIC PRESERVATION REQUIREMENTS. FINAL SELECTIONS TO BE
APPROVED BY CONSTRACTING OFFICER.
E. ALL CORE DRILL LOCATIONS ARE TO BE VERIFIED BY GENERAL
CONTRACTOR (GC) PRIOR TO DRILLING. GC IS TO COORDINATE ALL FINAL
CORE DRILL LOCATIONS WITH ASSOCIATED TRADES PRIOR TO START OF
CONSTRUCTION.
F. EXISTING ROOF SYSTEM PENETRATIONS: COORDINATE DETAILS AND
CONSTRUCTION WITH MANUFACTURER AND INSTALLER OF EXISTING
ROOF SYSTEM TO AVOID LOSS OF EXISTING ROOF WARRANTY
G. CONTRACTOR TO PROVIDE BLOCKING AT ALL SURFACE (WALL, CEILING)
MOUNTED FIXTURES AND EQUIPMENT AS REQUIRED.
H. REMOVAL AND REINSTALLATION OF EXISTING GUTTERS AND
DOWNSPOUTS REQUIRED TO COMPLETE NEW WORK IS TO NOT VOID
EXISTING GUTTER AND DOWNSPOUT WARRANTIES.
I. REMOVAL AND REINSTALLATION OF EXISTING LIGHTNING PROTECTION
SYSTEM REQUIRED TO COMPLETE NEW WORK IS TO NOT VOID EXISTING
GUTTER AND DOWNSPOUT WARRANTIES.
GENERAL NOTES:
A. CONTRACTOR IS TO FIELD VERIFY ALL DIMENSIONS AND EXISTING
CONDITIONS PRIOR TO START OF EXTERIOR WALL REPAIR
B. ALL SURFACES SHOULD BE STAGED TO ALLOW FOR HANDS ON INSPECTION
AND ANY REPAIRS IF NECESSARY
C. ALL DAMAGED MASONRY JOINTS OF SECTIONS B AND C ARE TO BE
REPOINTED (TUCK POINTING). ALL DAMAGED MORTAR JOINTS ARE TO BE
GROUND-OUT AND POINTED WITH NEW MORTAR. NEW MORTAR IS TO BE THE
SAME COMPOSITION AS EXISTING MORTAR. ALSO SEE SPECIFICATIONS
SECTION 04 01 20.70
D. ALL LOOSE LIMESTONE AND BRICK TO BE REMOVED, CLEANED AND
REPOSITIONED IN PLACE
E. ALL MISSING, SPALLED, BROKEN AND CHIPPED BRICK TO BE REMOVED AND
REPLACED WITH NEW TO MATCH EXISTING. ALSO SEE BUILDING EXTERIOR
FINISHES ON SHEET AE215.
F. WHEN REPLACING MASONRY OR FILLING IN MASONRY AREAS, NEW
MASONRY IS TO BE KEYED INTO EXISTING MASONRY. USE NEW NON-
CORROSIVE ANCHORS AND/ OR TIES AS REQUIRED.
G. ALL EXTERIOR SURFACES OF SECTIONS B AND C ARE TO BE CLEANED AND
WASHED TO REMOVE GRIME. APPLY CLEAR ANTI-GRAFFITI COATING. ALSO
SEE SPECIFICATIONS SECTIONS 03 01 30 AND 04 01 20.70
H. ALL LIMESTONE WITH CHIPPING LESS THAN 3 INCHES TO BE REPAIRED WITH
COMPOSITE PATCHING/ REPAIR. COMPOSITE PATCHING TO BE DONE WITH
CEMENT TYPE PATCH MATERIAL AND TO MATCH EXISINTG STONE COLOR,
TEXTURE, AND REPLICATE EXISTING SURFACE TOOLING, AND ADHERE WELL
TO EXISTING STONE SUBSTRATE, AND IS TO NOT CAUSE DETERIORATION OF
SURROUNDING STONE(S).
I. ALL LIMESTONE WITH CHIPPING 3 INCHES AND LARGER TO BE PARTIALLY
REPLACED OR TO BE PIECED-IN WITH NATURAL OR PRECAST STONE-
DUTCHMAN REPAIR. FOR DUTCHMAN REPAIR SEE SPECIFICATIONS SECTION
04 01 20.70
J. ALL CONTROL JOINTS IN SECTIONS B AND C, BETWEEN SECTIONS A AND B
AND BETWEEN C AND D, ARE TO BE RESEALED. PREPARE SURFACES
BEFORE RESEALING. SEE SPECIFICATIONS SECTION 07 92 00
K. IN ADDITION TO SPECIFIC LOCATIONS DENOTED ON SHEETS AD401, AD402,
AD403, AND AE215, CONTRACTOR SHALL USE THE FOLLOWING QUANTITIES
WHEN PRICING WALL REPAIRS FOR INTERIOR AND EXTERIOR:
A. 1,060 SF BRICK/ MORTAR/ MASONRY REPAIRS
B. 1,461 SF OF STUCCO REPAIRS
C. 100 SF OF LIMESTONE PRECAST CONCRETE
D. 1,461 SF PAINTED/ PARGED CONCRETE
L. REFER TO STRUCTURAL DRAWINGS TO DEVELOP QUANTITY TAKE-OFF FOR
ABOVE AND BELOW CONCRET FLOOR/ DECK/ BEAMS SPALLING AND
SPALLING WITHIN TUNNELS
EXTERIOR WALL REPAIR NOTES:
305305
LIMESTONE OR BRICK
SURFACE SEAL FOR EPOXY
TO BE REMOVED AFTER
COMPLETED PROCEDURE
EXISTING CRACK OR
MATERIAL DEFECT
GRIND BACK EXISTING TIE.
PRIME W/ RUST INHIBITING
PAINT. FIELD VERIFY
EXISTING CONDITIONS
-GRIND SQUARE EDGE
1/2" DEEP
PRIME EXPOSED SURFACES
WITH EPOXY RESIN BINDER
DRILL-IN 3/8" DIA HILTI
ADHESIVE ANCHOR AT OLD
TIE LOCATIONS
REMOVE LOOSE PIECES
AND DEBRIS. CLEAN
SURFACES AND PREPARE
TO RECEIVE NEW FORM
EPOXY RESIN MORTAR
FORMED TO ORIGINAL
PROFILE OF SPALLED UNIT
ONLY AS NECESSARY
REPAIR JOINT AS
REQUIRED. SEE DETAIL
H5-A/AE215
REPAIR JOINT AS REQUIRED.
SEE DETAIL H5-A/AE215
EXISTING TIE. CLEAN LOOSE RUST, PREPARE
EXPOSED SURFACES, AND COAT W/ EPOXY
BENT SST 1/4" DIA ROD DOWEL.
PROVIDE MIN 2" COVER
PRIME EXPOSED SURFACES WITH
EPOXY RESIN BINDER
GRIND SQUARE EDGE 1/2" DEEP
REMOVE LOOSE PIECES AND DEBRIS.
CLEAN SURFACES AND PREPARE TO
RECEIVE NEW FORM
SINGLE-COMPONENT, CEMENTITIOUS,
MENERAL-BASED MORTAR FORMED TO
ORIGINAL PROFILE OF SPALLED UNIT ONLY AS
NECESSARY. COLOR TO MATCH EXISTING
LIMESTONE. FOLLOW CONTOURS AND PROFILE
OF ADJACENT EXISTING STONE SURFACES
A B C D
EXISTING MORTAR
W
ID
T H
RAKE OUT 2.5 TIMES
THE WIDTH , NOT
LESS THAN 1/2" NOR
LESS THAN
REQUIRED TO
EXPOSE SOUND
MORTAR
EXISTING MORTAR EXISTING MORTAR EXISTING MORTAR
EXISTING BRICK EXISTING BRICK EXISTING BRICK EXISTING BRICK
3/8" MAX LAYERS
OF POINTING
MORTAR
W
ID
T H
W
= W
5/8".
IF WIDTH IS
GREATER THAN
1/2" + BACKER
ROD DIA
3/8" MAX LAYERS
OF POINTING
MORTAR
PATCH
SPALLED
EDGES PRIOR
TO POINTING
BUILDING EXTERIOR FINISHES
APPROVED BY USACE, MATCHING SECTIONS A AND G FOR CONTINUITY OF EASTHETICS
TYPE
MARK
MATERIAL MANUFACTURER PATTERN/ SERIES SIZE COLOR NOTES & COMMENTS
EXTERIOR WALLS
FB-1
GR-2
EXTERIOR WINDOWS
MECHANICAL YARD
EXTERIOR SIGNAGE
STUCCO AT INFILL WINDOWS
LINTELS
GROUT
FACE BRICK
STUCCO
DOORS
MECHANICAL LOUVERS
CURRIES TECHNICAL MANUAL PANEL DOOR SELECTION
SHERWIN-WILLIAMS
SHERWIN-WILLIAMS
SHERWIN-WILLIAMS
CHEROKEE BRICK AND TILE
GREENHECK
ARCHITECTURAL PANELS
MATCH EXISTING CHEROKEE RED TO MATCH SECTIONS A AND G
TO MATCH SECTIONS A AND G
SEE AE601 AND AE602
P: 706-577-3009ARGOS SAHARA
SW-6006 BLACK BEAN
SW-6006 BLACK BEAN
7684 CONCORD BUFF
CLASSIC BRONZE GF108
E6 PANEL DOOR
MATCH EXISTING
MATCH EXISTING
SIGNS SHERWIN-WILLIAMS SW-6006 BLACK BEAN TO MATCH SECTIONS A AND G
SEE AG-SERIES SHEETS
PC-1 PRE-CAST MILLER-MIZE PRECAST, INC.
SHERWIN-WILLIAMS
MMPI (D)
SW-2808 ROCKWOOD DARK BROWN
LIGHT BUFF TO MATCH SECTIONS A AND G
TO MATCH SECTIONS A AND G
AT FRAMES, MULLIONS, MUNTINS. TO MATCH SECTIONS A AND G
AT OPENINGS W/ LOUVER(S). TO MATCH SECTIONS A AND G
TO MATCH SECTIONS A AND G
ALSO SEE DOOR SCHEDULE LEGEND
STANDARD KYNAR
INSULATED PANEL
1" INSULATED PANEL
GLAZING
SPANDREL GLASS
CAULK
CAST STONE SILL
MAPES
MAPES
SOLARBAN
MAPES
PECORA SEALANTS
BELLAVANT
ARCHITECTURAL PANELS
ARCHITECTURAL PANELS
MANSARD BROWN
DARK BRONZE
SOLARBRONZE #2
DARK BRONZE
CLASSIC BRONZE 046
PATINA DSF1-203
GATES
IP-1
IP-2
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
S A
V A
N N
A H
D
IS
T R
IC
T
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
S A
V A
N N
A H
G
E O
R G
IA
JO
N
E S
F R
A N
K
LI
N R
D , S
U
IT
E
R A
LE
IG
H , N
C
-3
(9
1-
(9
1-
F
A X
LI
C
E N
S E
F
-0
F O
R T
B E
N N
IN
G
G
A B
U
IL
D
IN
G
T
R A
IN
E
E B
A R
R A
C K
S U
P G
R A
D E
P R
O G
R A
M
(T B
U P
P
H A
S E
F
Y P
N
FOR OFFICIAL USE ONLY
AE215
E X
T E
R
IO
R F
IN
IS
H E
S A
N D
W A
L L R
E P
A
IR
D E
T A
IL
S
Z K
A S
K Y
D V
A N
L O
O N
K B
R O
D B
E R
K B
R O
D B
E R
J U
L Y
W H
N B
- 7 -1
-2
C
A T
E G
O R
Y C
O D
E
F
IL
E N
A M
E A
E .D
W G
R E
A D
Y T
O A
D V
E R
T
IS
E
R T
A
KEYNOTES
008 EXISTING MASONRY WALL. PATCH, REPAIR AS REQUIRED. FINISH AS
INDICATED. SEE SHEET AE215 FOR ADDITIONAL INFORMATION - TYPICAL
009 EXISTING STUCCO WALL. PATCH, REPAIR AS REQUIRED AND MATCH
ADJACENT FINISH AND TEXTURE. PREPARE SURFACES TO RECEIVE
PAINT AS INDICATED. SEE SHEET AE215 FOR ADDITIONAL INFORMATION
- TYPICAL
020 EXISTING GUTTER AND DOWNSPOUTS. REMOVE AND REINSTALL AS
REQUIRED TO COMPLETE NEW WORK
116 EXISTING HOSE BIB. SEE PLUMBING DRAWINGS
301 EXISTING VINES. REMOVE IN THEIR ENTIRETY, INCLUDING IN BRICK
JOINTS AND AIR SPACE BEHIND BRICK - TYPICAL
302 EXISTING BRICK CRACK. CLEAN, PATCH, REPAIR AS REQUIRED. SEE
SHEET AE215 AND SPECIFICATIONS FOR ADDITIONAL INFORMATION -
TYPICAL
303 EXISTING LIMESTONE. CLEAN, PATCH, REPAIR AS REQUIRED. SEE
SHEET AE215 AND SPECIFICATIONS FOR ADDITIONAL INFORMATION -
TYPICAL
304 AREA OF REMOVAL OF EXISTING BRICK REPAIR AND REPLACE WITH
NEW BRICK TO MATCH ORIGINAL EXISTING BRICK - TYPICAL
305 REMOVE VENT IN ITS ENTIRY. INFILL OPENING TO MATCH ADJACENT
MATERIALS, SURFACES AND FINISH, OR NEW LOUVER. SEE MECHANICAL
DRAWINGS FOR ADDITIONAL INFORMATION - TYPICAL
306 PATCH, REPAIR STUCCO TEXTURE, FINISH, AND APPLICATION METHOD
TO MATCH ORIGINAL EXISTING STUCCO. SEE SHEET AE215 FOR
ADDITIONAL INFORMATION - TYPICAL
307 REMOVE LOUVERS IN THEIR ENTIRY. INFILL OPENING TO MATCH
ADJACENT MATERIALS, SURFACES AND FINISH, OR NEW LOUVER. SEE
MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION - TYPICAL
1" = 1'-0"L1
EXT. FACE BRICK - TYP
1" = 1'-0"L5
EXT. FACE BRICK - TYP
1" = 1'-0"D1
EXT. STUCCO - TYP
1" = 1'-0"L9
EXT. FACE BRICK - TYP
1" = 1'-0"L13
EXT. FACE BRICK - TYP
1" = 1'-0"H1
EXT. FACE BRICK - TYP
NTSD13
LIMESTONE AND BRICK
CRACK REPAIR DETAIL -
TYPICAL
NTSD9
LIMESTONE SPALL REPAIR
DETAIL - TYPICAL
NTSD5
LIMESTONE SPALL REPAIR
DETAIL - TYPICAL
NTSH9
MORTAR JOINT REPAIR DETAILS -
TYPICAL
1" = 1'-0"H5
EXT. FACE BRICK - TYP
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/1
/2
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/3
/2
07/22/21
AE215 EXTERIOR FINISHES AND WALL REPAIR DETAILS
File details come from the government source that posted it. Updated .