This solicitation is for repair work on Building 399 Sections B and C at Fort Benning, Georgia. The scope of work includes repairs to exterior walls, windows, fire protection, interior walls, doors, interior finishes, floors, ceilings, plumbing, HVAC, building controls, electrical, communications, building information systems, site utilities, and minor parking improvements. Demolition and HAZMAT/asbestos abatement are also required. The acquisition will be awarded as a 100% competitive full and open unrestricted contract, with a price evaluation preference for HUBZone small businesses. The contract value is estimated between $25-100 million. The point of contact is Mr. Hector L. Sierra-Almedina of the Army Corps of Engineers Savannah District. Bids are due in response to Solicitation Number W912HN21B3007.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A. CONTRACTOR TO FIELD VERIFY ALL DIMENSION AND EXISTING
CONDITIONS PRIOR TO START OF CONSTRUCTION. IF ANY DISCREPANCIES
WITH CONSTRUCTION DOCUMENTS, CONTRACTOR IS TO INFORM
CONTRACTING OFFICER IN WRITING PRIOR TO START OF CONSTRUCTION.
B. CONTRACTOR IS TO PROTECT ALL EXISTING ITEMS TO REMAIN FROM
DAMAGE DURING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR
REPAIRING, AND/ OR REPLACING DAMAGED ITEMS TO REMAIN WITH
EQUAL OR BETTER, TO THEIR ORIGINAL STATE, AT NO COST TO
GOVERNMENT.
C. REPOINT LOOSE MORTAR JOINTS, REPAIR CRACKS AND DAMAGE AT ALL
EXISTING MASONRY WALLS. ALL EXTERIOR MASONRY REPAIRS SHALL
MATCH HISTORIC CHARACTER, COLOR, AND PATTERN OF EXISTING
FACADE. ALL WORK TO BE AS PER HISTORIC PRESERVATION
REQUIREMENTS. FINAL SELECTIONS TO BE APPROVED BY CONTRACTING
OFFICER.
D. CLEAN AND PATCH ALL EXISTING STUCCO. REPAIR CRACKS AND DAMAGE.
ALL EXTERIOR STUCCO REPAIRS SHALL MATCH HISTORIC CHARACTER,
COLOR, AND PATTERN OF EXISTING FACADE. ALL WORK TO BE AS PER
HISTORIC PRESERVATION REQUIREMENTS. FINAL SELECTIONS TO BE
APPROVED BY CONSTRACTING OFFICER.
E. ALL CORE DRILL LOCATIONS ARE TO BE VERIFIED BY GENERAL
CONTRACTOR (GC) PRIOR TO DRILLING. GC IS TO COORDINATE ALL FINAL
CORE DRILL LOCATIONS WITH ASSOCIATED TRADES PRIOR TO START OF
CONSTRUCTION.
F. EXISTING ROOF SYSTEM PENETRATIONS: COORDINATE DETAILS AND
CONSTRUCTION WITH MANUFACTURER AND INSTALLER OF EXISTING
ROOF SYSTEM TO AVOID LOSS OF EXISTING ROOF WARRANTY
G. CONTRACTOR TO PROVIDE BLOCKING AT ALL SURFACE (WALL, CEILING)
MOUNTED FIXTURES AND EQUIPMENT AS REQUIRED.
H. REMOVAL AND REINSTALLATION OF EXISTING GUTTERS AND
DOWNSPOUTS REQUIRED TO COMPLETE NEW WORK IS TO NOT VOID
EXISTING GUTTER AND DOWNSPOUT WARRANTIES.
I. REMOVAL AND REINSTALLATION OF EXISTING LIGHTNING PROTECTION
SYSTEM REQUIRED TO COMPLETE NEW WORK IS TO NOT VOID EXISTING
GUTTER AND DOWNSPOUT WARRANTIES.
GENERAL NOTES:
A. CONTRACTOR IS TO FIELD VERIFY ALL DIMENSIONS AND EXISTING
CONDITIONS PRIOR TO START OF EXTERIOR WALL REPAIR
B. ALL SURFACES SHOULD BE STAGED TO ALLOW FOR HANDS ON INSPECTION
AND ANY REPAIRS IF NECESSARY
C. ALL DAMAGED MASONRY JOINTS OF SECTIONS B AND C ARE TO BE
REPOINTED (TUCK POINTING). ALL DAMAGED MORTAR JOINTS ARE TO BE
GROUND-OUT AND POINTED WITH NEW MORTAR. NEW MORTAR IS TO BE THE
SAME COMPOSITION AS EXISTING MORTAR. ALSO SEE SPECIFICATIONS
SECTION 04 01 20.70
D. ALL LOOSE LIMESTONE AND BRICK TO BE REMOVED, CLEANED AND
REPOSITIONED IN PLACE
E. ALL MISSING, SPALLED, BROKEN AND CHIPPED BRICK TO BE REMOVED AND
REPLACED WITH NEW TO MATCH EXISTING. ALSO SEE BUILDING EXTERIOR
FINISHES ON SHEET AE215.
F. WHEN REPLACING MASONRY OR FILLING IN MASONRY AREAS, NEW
MASONRY IS TO BE KEYED INTO EXISTING MASONRY. USE NEW NON-
CORROSIVE ANCHORS AND/ OR TIES AS REQUIRED.
G. ALL EXTERIOR SURFACES OF SECTIONS B AND C ARE TO BE CLEANED AND
WASHED TO REMOVE GRIME. APPLY CLEAR ANTI-GRAFFITI COATING. ALSO
SEE SPECIFICATIONS SECTIONS 03 01 30 AND 04 01 20.70
H. ALL LIMESTONE WITH CHIPPING LESS THAN 3 INCHES TO BE REPAIRED WITH
COMPOSITE PATCHING/ REPAIR. COMPOSITE PATCHING TO BE DONE WITH
CEMENT TYPE PATCH MATERIAL AND TO MATCH EXISINTG STONE COLOR,
TEXTURE, AND REPLICATE EXISTING SURFACE TOOLING, AND ADHERE WELL
TO EXISTING STONE SUBSTRATE, AND IS TO NOT CAUSE DETERIORATION OF
SURROUNDING STONE(S).
I. ALL LIMESTONE WITH CHIPPING 3 INCHES AND LARGER TO BE PARTIALLY
REPLACED OR TO BE PIECED-IN WITH NATURAL OR PRECAST STONE-
DUTCHMAN REPAIR. FOR DUTCHMAN REPAIR SEE SPECIFICATIONS SECTION
04 01 20.70
J. ALL CONTROL JOINTS IN SECTIONS B AND C, BETWEEN SECTIONS A AND B
AND BETWEEN C AND D, ARE TO BE RESEALED. PREPARE SURFACES
BEFORE RESEALING. SEE SPECIFICATIONS SECTION 07 92 00
EXTERIOR WALL REPAIR NOTES:
305305
LIMESTONE OR BRICK
SURFACE SEAL FOR EPOXY
TO BE REMOVED AFTER
COMPLETED PROCEDURE
EXISTING CRACK OR
MATERIAL DEFECT
GRIND BACK EXISTING TIE.
PRIME W/ RUST INHIBITING
PAINT. FIELD VERIFY
EXISTING CONDITIONS
-GRIND SQUARE EDGE
1/2" DEEP
PRIME EXPOSED SURFACES
WITH EPOXY RESIN BINDER
DRILL-IN 3/8" DIA HILTI
ADHESIVE ANCHOR AT OLD
TIE LOCATIONS
REMOVE LOOSE PIECES
AND DEBRIS. CLEAN
SURFACES AND PREPARE
TO RECEIVE NEW FORM
EPOXY RESIN MORTAR
FORMED TO ORIGINAL
PROFILE OF SPALLED UNIT
ONLY AS NECESSARY
REPAIR JOINT AS
REQUIRED. SEE DETAIL
H5-A/AE215
REPAIR JOINT AS REQUIRED.
SEE DETAIL H5-A/AE215
EXISTING TIE. CLEAN LOOSE RUST, PREPARE
EXPOSED SURFACES, AND COAT W/ EPOXY
BENT SST 1/4" DIA ROD DOWEL.
PROVIDE MIN 2" COVER
PRIME EXPOSED SURFACES WITH
EPOXY RESIN BINDER
GRIND SQUARE EDGE 1/2" DEEP
REMOVE LOOSE PIECES AND DEBRIS.
CLEAN SURFACES AND PREPARE TO
RECEIVE NEW FORM
SINGLE-COMPONENT, CEMENTITIOUS,
MENERAL-BASED MORTAR FORMED TO
ORIGINAL PROFILE OF SPALLED UNIT ONLY AS
NECESSARY. COLOR TO MATCH EXISTING
LIMESTONE. FOLLOW CONTOURS AND PROFILE
OF ADJACENT EXISTING STONE SURFACES
A B C D
EXISTING MORTAR
W
ID
T H
RAKE OUT 2.5 TIMES
THE WIDTH , NOT
LESS THAN 1/2" NOR
LESS THAN
REQUIRED TO
EXPOSE SOUND
MORTAR
EXISTING MORTAR EXISTING MORTAR EXISTING MORTAR
EXISTING BRICK EXISTING BRICK EXISTING BRICK EXISTING BRICK
3/8" MAX LAYERS
OF POINTING
MORTAR
W
ID
T H
W
= W
5/8".
IF WIDTH IS
GREATER THAN
1/2" + BACKER
ROD DIA
3/8" MAX LAYERS
OF POINTING
MORTAR
PATCH
SPALLED
EDGES PRIOR
TO POINTING
BUILDING EXTERIOR FINISHES
APPROVED BY USACE, MATCHING SECTIONS A AND G FOR CONTINUITY OF EASTHETICS
TYPE
MARK
MATERIAL MANUFACTURER PATTERN/ SERIES SIZE COLOR NOTES & COMMENTS
EXTERIOR WALLS
FB-1
GR-2
EXTERIOR WINDOWS
MECHANICAL YARD
EXTERIOR SIGNAGE
STUCCO AT INFILL WINDOWS
LINTELS
GROUT
FACE BRICK
STUCCO
DOORS
MECHANICAL LOUVERS
CURRIES TECHNICAL MANUAL PANEL DOOR SELECTION
SHERWIN-WILLIAMS
SHERWIN-WILLIAMS
SHERWIN-WILLIAMS
CHEROKEE BRICK AND TILE
GREENHECK
ARCHITECTURAL PANELS
MATCH EXISTING CHEROKEE RED TO MATCH SECTIONS A AND G
TO MATCH SECTIONS A AND G
SEE AE601 AND AE602
P: 706-577-3009ARGOS SAHARA
SW-6006 BLACK BEAN
SW-6006 BLACK BEAN
7684 CONCORD BUFF
CLASSIC BRONZE GF108
E6 PANEL DOOR
MATCH EXISTING
MATCH EXISTING
SIGNS SHERWIN-WILLIAMS SW-6006 BLACK BEAN TO MATCH SECTIONS A AND G
SEE AG-SERIES SHEETS
PC-1 PRE-CAST MILLER-MIZE PRECAST, INC.
SHERWIN-WILLIAMS
MMPI (D)
SW-2808 ROCKWOOD DARK BROWN
LIGHT BUFF TO MATCH SECTIONS A AND G
TO MATCH SECTIONS A AND G
AT FRAMES, MULLIONS, MUNTINS. TO MATCH SECTIONS A AND G
AT OPENINGS W/ LOUVER(S). TO MATCH SECTIONS A AND G
TO MATCH SECTIONS A AND G
ALSO SEE DOOR SCHEDULE LEGEND
STANDARD KYNAR
INSULATED PANEL
1" INSULATED PANEL
GLAZING
SPANDREL GLASS
CAULK
CAST STONE SILL
MAPES
MAPES
SOLARBAN
MAPES
PECORA SEALANTS
BELLAVANT
ARCHITECTURAL PANELS
ARCHITECTURAL PANELS
MANSARD BROWN
DARK BRONZE
SOLARBRONZE #2
DARK BRONZE
CLASSIC BRONZE 046
PATINA DSF1-203
GATES
IP-1
IP-2
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
S A
V A
N N
A H
D
IS
T R
IC
T
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
S A
V A
N N
A H
G
E O
R G
IA
JO
N
E S
F R
A N
K
LI
N R
D , S
U
IT
E
R A
LE
IG
H , N
C
-3
(9
1-
(9
1-
F
A X
LI
C
E N
S E
F
-0
F O
R T
B E
N N
IN
G
G
A B
U
IL
D
IN
G
T
R A
IN
E
E B
A R
R A
C K
S U
P G
R A
D E
P R
O G
R A
M
(T B
U P
P
H A
S E
F
Y P
N
FOR OFFICIAL USE ONLY
AE215
E X
T E
R
IO
R F
IN
IS
H E
S A
N D
W A
L L R
E P
A
IR
D E
T A
IL
S
Z K
A S
K Y
D V
A N
L O
O N
K B
R O
D B
E R
K B
R O
D B
E R
J U
L Y
W H
N B
- 7 -1
-2
C
A T
E G
O R
Y C
O D
E
F
IL
E N
A M
E A
E .D
W G
R E
A D
Y T
O A
D V
E R
T
IS
E
R T
A
KEYNOTES
008 EXISTING MASONRY WALL. PATCH, REPAIR AS REQUIRED. FINISH AS
INDICATED. SEE SHEET AE215 FOR ADDITIONAL INFORMATION - TYPICAL
009 EXISTING STUCCO WALL. PATCH, REPAIR AS REQUIRED AND MATCH
ADJACENT FINISH AND TEXTURE. PREPARE SURFACES TO RECEIVE
PAINT AS INDICATED. SEE SHEET AE215 FOR ADDITIONAL INFORMATION
- TYPICAL
020 EXISTING GUTTER AND DOWNSPOUTS. REMOVE AND REINSTALL AS
REQUIRED TO COMPLETE NEW WORK
116 EXISTING HOSE BIB. SEE PLUMBING DRAWINGS
301 EXISTING VINES. REMOVE IN THEIR ENTIRETY, INCLUDING IN BRICK
JOINTS AND AIR SPACE BEHIND BRICK - TYPICAL
302 EXISTING BRICK CRACK. CLEAN, PATCH, REPAIR AS REQUIRED. SEE
SHEET AE215 AND SPECIFICATIONS FOR ADDITIONAL INFORMATION -
TYPICAL
303 EXISTING LIMESTONE. CLEAN, PATCH, REPAIR AS REQUIRED. SEE
SHEET AE215 AND SPECIFICATIONS FOR ADDITIONAL INFORMATION -
TYPICAL
304 AREA OF REMOVAL OF EXISTING BRICK REPAIR AND REPLACE WITH
NEW BRICK TO MATCH ORIGINAL EXISTING BRICK - TYPICAL
305 REMOVE VENT IN ITS ENTIRY. INFILL OPENING TO MATCH ADJACENT
MATERIALS, SURFACES AND FINISH, OR NEW LOUVER. SEE MECHANICAL
DRAWINGS FOR ADDITIONAL INFORMATION - TYPICAL
306 PATCH, REPAIR STUCCO TEXTURE, FINISH, AND APPLICATION METHOD
TO MATCH ORIGINAL EXISTING STUCCO. SEE SHEET AE215 FOR
ADDITIONAL INFORMATION - TYPICAL
307 REMOVE LOUVERS IN THEIR ENTIRY. INFILL OPENING TO MATCH
ADJACENT MATERIALS, SURFACES AND FINISH, OR NEW LOUVER. SEE
MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION - TYPICAL
1" = 1'-0"L1
EXT. FACE BRICK - TYP
1" = 1'-0"L5
EXT. FACE BRICK - TYP
1" = 1'-0"D1
EXT. STUCCO - TYP
1" = 1'-0"L9
EXT. FACE BRICK - TYP
1" = 1'-0"L13
EXT. FACE BRICK - TYP
1" = 1'-0"H1
EXT. FACE BRICK - TYP
NTSD13
LIMESTONE AND BRICK
CRACK REPAIR DETAIL -
TYPICAL
NTSD9
LIMESTONE SPALL REPAIR
DETAIL - TYPICAL
NTSD5
LIMESTONE SPALL REPAIR
DETAIL - TYPICAL
NTSH9
MORTAR JOINT REPAIR DETAILS -
TYPICAL
1" = 1'-0"H5
EXT. FACE BRICK - TYP
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/1
/2
DVANLOON
Image
DVANLOON
Image
DVANLOON
Text Box 07/22/21
UNIT-D
B114
BATHROOM - D
/2
AE410 A14
S
IM
K14
S
IM
E14 SIM
A17 SIM
7' - 6 7/8"
2' - 7" 5' - 0"
03 0101
04 09
11A
09A
2' - 0"
/4
1' - 3"
2' - 9"
/8 " 3' - 0"
CORR
C139AE414
L1 SIM
L6
S
IM
AE415
G7
L7
11' - 1"
1' - 8 1/2"
11A
12 03B
02A
C134-A
11A
1' - 6"
ABA UNIT-D
C134
ABA BATH - D
2' - 6"
ALIGN
5' - 0"
UNIT-F
C234
BATHROOM - F
AE415 L12
03C
SEE FLOOR PLANS
FOR PARTITION TYPE
AE414
F13 SIM
A12
G12
A
R
T B
C 084
PT-6
PTB-2
PWT-1
PTB-1
B
C
F
K D
D
PT-6
PTB-2
PTB-1
PWT-1
L B
A
K
E
PT-6
PTB-2
PWT-1
PTB-1
A. SEE SHEET AF601 FOR UNIT BATHROOM TYPICAL FLOOR
FINISH PLAN
B. SEE SHEETS AF601, AF602 AND AF603 FOR FINISH KEY AND
FINISH SCHEDULE
C. SEE SHEET AF601 FOR FLOOR TRANSITION DETAILS
D. SEE SHEET AE413 FOR TOILET ACCESSORY SCHEDULE
E. REFER TO SHEET A-002 FOR ABA MOUNTING HEIGHTS
F. SEE IF111 FOR EQUIPMENT LEGEND
G. SEE IF-SHEETS FOR FURNITURE LAYOUTS
H. SEE SHEET AE504 FOR MILLWORK DETAILS
I. ALL LOCKER ROOM SHOWERS TO HAVE ROLL-IN TYPE
FLOOR TRANSITION. REFER TO SHEET AE503 FOR FLOOR
TRANSITION DETAILS.
J. SEE AE508 FOR CEILING DETAILS
GENERAL NOTES:
LEGEND:
1/2 HOUR SMOKE RATED WALL
1 HOUR FIRE RATED WALL
PARTITION TYPE SYMBOL, REFER
TO SHEETS AE701, AE702, AND
AE703
NEW INFILL WALL
NEW INTERIOR PARTITION
EXISTING WALL TO REMAIN
2 HOUR FIRE RATED WALL,
SEE LIFE SAFETY PLANS
A
B
PT-6
PTB-2
PTB-1
PWT-1
T
D
D
C
PT-6
PTB-2
PWT-1
PTB-1
E
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
S A
V A
N N
A H
D
IS
T R
IC
T
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
S A
V A
N N
A H
G
E O
R G
IA
JO
N
E S
F R
A N
K
LI
N R
D , S
U
IT
E
R A
LE
IG
H , N
C
-3
(9
1-
(9
1-
F
A X
LI
C
E N
S E
F
-0
F O
R T
B E
N N
IN
G
G
A B
U
IL
D
IN
G
T
R A
IN
E
E B
A R
R A
C K
S U
P G
R A
D E
P R
O G
R
U P
P
H A
S E
F
Y P
N
FOR OFFICIAL USE ONLY
AE415
E N
L A
R G
E D
B A
T H
R O
O M
P L A
N S
I
N T
E R
IO
R
E L E
V A
T
IO
N S
T
Y P
IC
A
L U
N
IT
S
D
E
F
A N
D G
Z K
A S
K Y
D V
A N
L O
O N
K B
R O
D B
E R
K B
R O
D B
E R
J U
L Y
W H
N B
- 7 -1
-2
C
A T
E G
O R
Y C
O D
E
F
IL
E N
A M
E A
E .D
W G
R E
A D
Y T
O A
D V
E R
T
IS
E
R T
A
PLAN
NORTH
1/2" = 1'-0"A1
ENLARGED PLAN (BATHROOM - D)
1/2" = 1'-0"A7
ENLARGED PLAN (ABA BATH - D)
0 1' 2' 4'
1/2" = 1'-0"H1
ENLARGED PLAN, BATHROOM - F /
BATHROOM - E (OPP HAND)
1/2" = 1'-0"L12
ELEVATION (BATHROOM - F)
1/2" = 1'-0"G7
ELEVATION (ABA BATH - D)
1/2" = 1'-0"L7
ELEVATION (ABA BATH - D)
KEYNOTES
084 SURFACE MOUNTED LIGHT FIXTURE
103 SHOWER CURB. SEE SHEET AE503 FOR DETAILS
114 12"X12" ACCESS PANEL, 12" AFF. SEE MECHANICAL
DRAWINGS
157 SHELF AND HANGER ROD. SEE SHELF DETAILS ON
SHEET AE503
1/2" = 1'-0"G12
ELEVATION (BATHROOM - F)
1/2" = 1'-0"A12
ELEVATION (BATHROOM - F)
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/1
/2
DVANLOON
Image
DVANLOON
Image
DVANLOON
TYPE F TYPE P TYPE G
GL5 WITH
APPLIED GRID
(SAME FIRE
RATING AS DOOR)
TYPE FG
GL5
(SAME FIRE
RATING AS DOOR)
TYPE N
GL5 4"X24" VISION
PANEL (SAME FIRE
RATING AS DOOR)
4" 6"
4" 4"
KICK PLATE
PER
SCHEDULE
KICK PLATE
PER
SCHEDULE
HM DOOR.
FINISH AS
SCHEDULED
TYPE 1 TYPE 2 TYPE 3A
TYPE 4
P E
R S
C H
E D
U L E
2"
SCHEDULE
PER
2"
P E
R S
C H
E D
U L E
P E
R S
C H
E D
U L E
2"
SCHEDULE
PER
2"
TYPE 5
5' - 7"
'-8
(L
E V
E L
P E
R S
C H
E D
U L E
F V
V
A R
IE
S
PER SCHEDULE
3' - 4"
'-8
(L
E V
E L
P E
R S
C H
E D
U L E
F V
V
A R
IE
S
PER SCHEDULE
3' - 4"
P E
R S
C H
E D
U L E
2" PER SCHEDULE 2"
1' - 11"
TYPE 6
'-8
(L
E V
E L
P E
R S
C H
E D
U L E
F V
V
A R
IE
S
2" PER SCHEDULE 2"
TYPE 3
P E
R S
C H
E D
U L E
2" PER SCHEDULE 2"
TYPE 0
P E
R S
C H
E D
U L E
PER SCHEDULE
GL3 WITH
APPLIED GRID,
TYP.
GL2
GL3 - 1ST FLOOR.
GL2 - 2ND & 3RD
FLOORS, TYP.
GL3 - 1ST FLOOR.
GL2 - 2ND & 3RD
FLOORS, TYP.
ALUMINUM STOREFRONT
SYSTEM WITH HOLLOW
METAL DOOR, TYP. FOR
EXTERIOR DOOR SYSTEMS
SEE AE607 FOR DETAILS
IP-1
AL ALUMINUM
WD WOOD
HM HOLLOW METAL
STC SOUND TRANSMISSION COEFFICIENT
AT/FP ANTI-TERRORISM/ FORCE PROTECTION
F FLUSH
N NARROW LITE
P PANELED
FG FULL GLASS
FL FULL LOUVER
PRE. FIN. PREFINISHED (FACTORY FINISH)
PNT PAINTED
GL1 INSULATED/ LAMINATED 0.030 PVB/TINTED/ LOW-E
GL2 INSULATED/ LAMINATED 0.030 PVB/CLEAR/ LOW-E
GL3 INSULATED/ LAMINATED 0.030 PVB/SPANDREL/ LOW-E
GL4 RATED 1/2" LAMINATED/ CLEAR/ 0.030 PVB
GL5 FIRE RATED GLASS (SAME FIRE RATING AS DOOR)
IP-1 INSULATED PANEL (SEE AE215 FOR FINISH SCHEDULE)
IP-2 INSULATED PANEL (SEE AE215 FOR FINISH SCHEDULE)
DOOR SCHEDULE LEGEND
REMARKS:
1. 1 PR. EQUAL SIZE DOORS WITHIN SPECIFIED WIDTH IN SCHEDULE.
2. VISION PANEL MARKED D-H-90 OR D-H-W-90.
3. UNDERCUT DOOR BY 1-1/2" FOR AIR FLOW
4. FIRE RATED VISION PANEL ON DOOR, SAME FIRE RATING AS DOOR
5. DOOR VIEWER CENTERED ON DOOR AT 5'-6" AFF.
6. VISION PANEL MARKED D-H-45 OR D-H-W-45.
7. BIFOLD DOORS - 4 EQUAL SIZE DOORS WITHIN SPECIFIED WIDTH IN SCHEDULE.
8. DOOR CLOSER WITH HOLD OPEN ARM.
9. DRYWALL OPENING.
10. GLASS LITE/ VISION PANEL WITH BLAST RESISTANT GLASS.
11. FIELD VERIFY EXISTING DOOR SIZE.
12. SEE STRUCTURAL FOR DOOR HEAD DETAILS.
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
S A
V A
N N
A H
D
IS
T R
IC
T
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
S A
V A
N N
A H
G
E O
R G
IA
JO
N
E S
F R
A N
K
LI
N R
D , S
U
IT
E
R A
LE
IG
H , N
C
-3
(9
1-
(9
1-
F
A X
LI
C
E N
S E
F
-0
F O
R T
B E
N N
IN
G
G
A B
U
IL
D
IN
G
T
R A
IN
E
E B
A R
R A
C K
S U
P G
R A
D E
P R
O G
R
U P
P
H A
S E
F
Y P
N
FOR OFFICIAL USE ONLY
AE601
D O
O R
S C
H E
D U
L E
D
O O
R A
N D
F R
A M
E T
Y P
E S
Z K
A S
K Y
D V
A N
L O
O N
K B
R O
D B
E R
K B
R O
D B
E R
J U
L Y
W H
N B
- 7 -1
-2
C
A T
E G
O R
Y C
O D
E
F
IL
E N
A M
E A
E .D
W G
R E
A D
Y T
O A
D V
E R
T
IS
E
R T
A
DOOR SCHEDULE - LEVEL 01 & LEVLEL 02
DOOR
ID
ROOM NAME
ROOM
NUMBER
DOOR
HARDWARE
HEADING NO.
FRAME
REMARKS
SIZE TYPE
MAT'
L
CLASS PERFORMANCE FINISH COATING RATING GLAZING ACCOUST.
MAT'L FINISH COATING TYPE
DETAIL
HEAD JAMB THRESHOLD
TOF
B100-3 EXISTING STORAGE B100-3 2' - 5" x 6' - 3" x 0' - 2" F HM PNT 12 HM PNT 1 DH6/AE608 (SIM) DJ6/AE608 (SIM) - 11
C100-3 EXISTING STORAGE C100-3 2' - 5" x 6' - 3" x 0' - 2" F HM PNT 12 HM PNT 1 DH6/AE608 (SIM) DJ6/AE608 (SIM) - 11
C100b-3 EXISTING STORAGE C100b-3 2' - 5" x 6' - 3" x 0' - 2" F HM PNT 12 HM PNT 1 DH6/AE608 (SIM) DJ6/AE608 (SIM) - 11
1ST FLOOR
B MECH. ENCLOSURE B 9' - 2" x 8' - 0" x 0' - 2" - - - - - - N/A - - -
B100 EXISTING STORAGE B100 5' - 0" x 7' - 0" x 0' - 2" - - - 11 - - N/A - - -
B100-2 EXISTING STORAGE B100 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 12 HM PNT 2 DH6/AE608 (SIM) DJ6/AE608 (SIM) - 11
B109 MECH RM B109 6' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. STC 50 13 HM PNT 3A DH3/AE607 DJ3/AE607 - 1
B111 ELEC RM B111 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. - 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
B127-E CORR B127 3' - 4" x 7' - 6" x 0' - 2" P HM PNT 1 AL PRE. FIN. 4 DH1/AE607; DH1a/AE608 DJ1/AE607 T3/AE607 10
B129 JANITOR B129 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 9 HM PNT 2 DH3/AE607 DJ3/AE607 -
B130-1 EGRESS CORRIDOR B130 3' - 0" x 7' - 0" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH3/AE607 DJ3/AE607 - 6, 8
B130-2 EGRESS CORRIDOR B130 3' - 0" x 7' - 0" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH3/AE607 DJ3/AE607 - 6, 8
B130-E EGRESS CORRIDOR B130 3' - 4" x 7' - 6" x 0' - 1 3/4" P HM PNT 1 AL PRE. FIN. 5 DH1/AE607; DH1a/AE608 DJ5/AE607 (SIM) T4/AE607 10
B131 LAUNDRY B131 3' - 0" x 7' - 0" x 0' - 2" N HM PNT 45 MIN. GL5 9 HM PNT 2 DH3/AE607 DJ3/AE607 - 4
B132 RESTROOM B132 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 20 MIN. 10 HM PNT 1 DH3/AE607 DJ3/AE607 -
B133 STOR. B133 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
B134 TELECOM B134 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. - 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
B135 EGRESS CORRIDOR B130 3' - 0" x 7' - 0" x 0' - 2" N HM PNT 45 MIN. GL5 7 HM PNT 2 DH3/AE607 DJ3/AE607 - 4
B135-E CORR B135 3' - 0" x 7' - 6" x 0' - 1 3/4" P HM PNT 1 AL PRE. FIN. 4 DH1/AE607; DH1b/AE608 DJ5/AE607 T3/AE607 10
B136 STAIR 1 B136 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10
B136-A STAIR 1 B136 3' - 0" x 4' - 10" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 1 - - - 11
B150 STOR. B150 2' - 0" x 5' - 1" x 0' - 2" F HM PNT 12 HM PNT 1 DH6/AE608 (SIM) DJ6/AE608 (SIM) T1/AE607 11
B151 STOR. B151 2' - 0" x 5' - 1" x 0' - 2" F HM PNT 12 HM PNT 1 DH6/AE608 (SIM) DJ6/AE608 (SIM) T1/AE607 12
C MECH. ENCLOSURE C 9' - 2" x 8' - 0" x 0' - 2" - - - - - - N/A - - -
C100 EXISTING STORAGE C100 5' - 0" x 7' - 0" x 0' - 2" - - - 11 - - N/A - - -
C100-2 EXISTING STORAGE C100 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 12 HM PNT 2 DH6/AE608 (SIM) DJ6/AE608 (SIM) - 11
C100b EXISTING STORAGE C100b 5' - 0" x 7' - 0" x 0' - 2" - - - 11 - - N/A - - -
C100b-2 EXISTING STORAGE C100b 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 12 HM PNT 2 DH6/AE608 (SIM) DJ6/AE608 (SIM) - 11
C113 MECH RM C113 6' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. STC 50 13 HM PNT 3A DH3/AE607 DJ3/AE607 - 1
C130 LAUNDRY C130 3' - 0" x 7' - 0" x 0' - 2" N HM PNT 45 MIN. GL5 9 HM PNT 2 DH3/AE607 DJ3/AE607 - 4
C132 LOCKERS (MEN) C132 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 10 HM PNT 1 DH4/AE607 DJ4/AE607 - 3
C133 LOCKERS (WOMEN) C133 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 10 HM PNT 1 DH4/AE607 DJ4/AE607 - 3
C136 OFFICERS LOUNGE C136 3' - 0" x 7' - 0" x 0' - 2" FG HM PNT 20 MIN. 3 HM PNT 2 DH3/AE607 DJ3/AE607 - 4
C137-O VESTIBULE C137 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - 0 - - - 9
C138 LOBBY C138 3' - 0" x 7' - 0" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH3/AE607 DJ3/AE607 - 6, 8
C138-E LOBBY C138 6' - 0" x 7' - 6" x 0' - 1 3/4" P HM PNT 2 AL PRE. FIN. 6 DH1/AE607; DH1a/AE608 DJ1/AE607 T3/AE607 1, 10
C139-O CORR C139 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - - - - 0 - - - 9
C140-E CORR C140 6' - 0" x 7' - 6" x 0' - 1 3/4" P HM PNT 2 AL PRE. FIN. 6 DH1/AE607; DH1b/AE608 DJ5/AE607 T3/AE607 1, 10
C141-E LOBBY C141 6' - 0" x 7' - 6" x 0' - 1 3/4" P HM PNT 2 AL PRE. FIN. 6 DH1/AE607; DH1b/AE608 DJ5/AE607 T3/AE607 1, 10
C142 RESTROOM C142 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 20 MIN. 10 HM PNT 1 DH3/AE607 DJ3/AE607 -
C143 ELEC RM C143 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
C144 STOR. C144 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
C145 TELECOMM C145 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
C146 STAIR 3 C146 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10
C146-A STAIR 3 C146 3' - 0" x 4' - 10" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 1 - - -
C146-E STAIR 3 C146 3' - 8" x 7' - 0" x 0' - 2" P HM PNT - 1 HM PNT 2 DH6/AE608 DJ6/AE608 T3/AE607
C147-O CORR C140 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - - - - - 0 - - - 9
C148-E CORR C148 3' - 4" x 7' - 6" x 0' - 1 3/4" P HM PNT 1 AL PRE. FIN. 4 DH1/AE607; DH1a/AE608 DJ1/AE607 T3/AE607 10
C149 CORR C149 3' - 0" x 7' - 0" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH3/AE607 DJ3/AE607 - 6, 8
C150-E LOBBY C150 6' - 0" x 7' - 6" x 0' - 1 3/4" P HM PNT 2 AL PNT 6 DH1/AE607; DH1b/AE608 DJ5/AE607 T3/AE607 1, 10
C151-E CORR C151 6' - 0" x 7' - 6" x 0' - 1 3/4" P HM PNT 2 AL PRE. FIN. 6 DH1/AE607; DH1b/AE608 DJ5/AE607 T3/AE607 1, 10
C152 RESTROOM C152 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 20 MIN. 10 HM PNT 1 DH3/AE607 DJ3/AE607 -
C153 ELEC RM C153 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
C154 STOR. C154 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
C155 TELECOM C155 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
C157 LAUNDRY C157 3' - 0" x 7' - 0" x 0' - 2" N HM PNT 45 MIN. GL5 9 HM PNT 2 DH3/AE607 DJ3/AE607 - 4
C158 ELEC RM C158 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
C158-0 ELEC RM C158 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - - - 0 - - - 9
C159 STAIR 2 C159 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10
C159-B STAIR 2 C159 3' - 0" x 4' - 10" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 1 - - -
C160 CORR C160 3' - 0" x 7' - 0" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH3/AE607 DJ3/AE607 - 6, 8
C161 CORR C161 3' - 0" x 7' - 0" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH3/AE607 DJ3/AE607 - 6, 8
C161-E CORR C161 3' - 4" x 7' - 6" x 0' - 1 3/4" P HM PNT 1 AL PRE. FIN. 4 DH1/AE607; DH1a/AE608 DJ1/AE607 T3/AE607 10
C170 STOR. C170 2' - 0" x 5' - 1" x 0' - 2" F HM PNT 12 HM PNT 1 DH6/AE608 (SIM) DJ6/AE608 (SIM) - 11
C171 STOR. C171 2' - 0" x 5' - 1" x 0' - 2" F HM PNT 12 HM PNT 1 DH6/AE608 (SIM) DJ6/AE608 (SIM) - 11
C172 STOR. C172 2' - 0" x 5' - 1" x 0' - 2" F HM PNT 12 HM PNT 1 DH6/AE608 (SIM) DJ6/AE608 (SIM) - 11
C173 STOR. C173 2' - 0" x 5' - 1" x 0' - 2" F HM PNT 12 HM PNT 1 DH6/AE608 (SIM) DJ6/AE608 (SIM) - 11
2ND FLOOR
B211 ELEC. RM. B211 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
B227-E CORR B227 3' - 4" x 7' - 6" x 0' - 1 3/4" P HM PNT 1 AL PRE. FIN. 4 DH1/AE607; DH1a/AE608 DJ1/AE607 T1/AE607 10
B229 JANITOR B229 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 9 HM PNT 2 DH3/AE607 DJ3/AE607 -
B230-E VESTIBULE B230 3' - 4" x 7' - 6" x 0' - 1 3/4" p HM PNT 1 AL PRE. FIN. 5 DH1/AE607; DH1a/AE608 DJ5/AE607 T1/AE607 10
B231 LAUNDRY B231 3' - 0" x 7' - 0" x 0' - 2" N HM PNT 45 MIN. GL5 9 HM PNT 2 DH3/AE607 DJ3/AE607 - 4
B232 RESTROOM B232 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 20 MIN. 10 HM PNT 1 DH3/AE607 DJ3/AE607 -
B233 STOR. B233 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
B234 TELECOM B234 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
B236 STAIR 1 B236 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10
C213 LOUNGE C213 6' - 0" x 7' - 0" x 0' - 2" FG HM PNT 20 MIN. GL5 13 HM PNT 3A DH3/AE607 DJ3/AE607 - 1, 4
C230 LAUNDRY C230 3' - 0" x 7' - 0" x 0' - 2" N HM PNT 45 MIN. GL5 9 HM PNT 2 DH3/AE607 DJ3/AE607 - 4
C231 LOUNGE C231 6' - 0" x 7' - 0" x 0' - 2" FG HM PNT 20 MIN. GL5 13 HM PNT 3A DH3/AE607 DJ3/AE607 - 1, 4
C238 CORR C238 3' - 0" x 7' - 0" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH3/AE607 DJ3/AE607 - 6, 8
C238-O CORR C238 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - - - 0 - - - 9
C240-E CORR C240 6' - 0" x 7' - 6" x 0' - 1 3/4" P HM PNT 2 AL PRE. FIN. 6 DH1/AE607; DH1b/AE608 DJ5/AE607 T1/AE607 1, 10
C241 JANITOR C241 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 9 HM PNT 2 DH3/AE607 DJ3/AE607 -
C242 RESTROOM C242 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 10 HM PNT 2 DH3/AE607 DJ3/AE607 -
C243 ELEC RM C243 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
C244 STOR. C244 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
C245 TELECOMM C245 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
C246 STAIR 3 C246 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10
C247-O CORR C247 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - - - 0 - - - 9
C248-E CORR C248 3' - 4" x 7' - 6" x 0' - 1 3/4" P HM PNT 1 AL PRE. FIN. 4 DH1/AE607; DH1a/AE608 DJ1/AE607 T1/AE607 10
C249-O CORR C249 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - - - - 0 - - - 9
C250-E LOBBY C250 6' - 0" x 7' - 6" x 0' - 1 3/4" P HM PNT 2 AL PRE. FIN. 6 DH1/AE607; DH1b/AE608 DJ5/AE607 T1/AE607 1, 10
C252 RESTROOM C252 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 20 MIN. 10 HM PNT 1 DH3/AE607 DJ3/AE607 -
C253 ELEC. RM. C253 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
C254 JC C254 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 9 HM PNT 2 DH3/AE607 DJ3/AE607 -
C255 TELECOM C255 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
C257 LAUNDRY C257 3' - 0" x 7' - 0" x 0' - 2" N HM PNT 45 MIN. GL5 9 HM PNT 2 DH3/AE607 DJ3/AE607 - 4
C258 STOR. C258 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
C259 STAIR 2 C259 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10
C260-O CORR C260 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - - - - 0 - - - 9
C261 CORR C261 3' - 0" x 7' - 0" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH3/AE607 DJ3/AE607 - 6, 8
C261-E CORR C261 3' - 4" x 7' - 6" x 0' - 1 3/4" P HM PNT 1 AL PRE. FIN. 4 DH1/AE607; DH1a/AE608 DJ1/AE607 T1/AE607 10
1/4" = 1'-0"
DOOR TYPES
1/4" = 1'-0"
FRAME TYPES
0 2' 4' 8' 12'
GENERAL NOTES - DOOR SCHEDULE:
A. FIELD VERIFY EXISTING CONDITIONS AT EXTERIOR DOOR
THRESHOLDS. USE APPROPRIATE THRESHOLD TYPES TO
SUIT EXISTING CONDITIONS
B. GENERAL CONTRACTOR IS RESPONSIBLE FOR SELECTING
CORRECT THRESHOLD TYPES TO FACILITATE SITE
CONDITIONS
C. REFER TO SHEET AF601 FOR FLOOR TRANSITION DETAILS
D. WHERE ALUMINUM STOREFRONT SYSTEMS ARE USED WITH
HM DOORS, COAT ALUMINUM FRAMES WITH CORROSION
PREVENTATIVE METAL COATINGS AT DOORWAYS TO
PREVENT DISSIMILAR METAL CORROSION
E. ALSO SEE SHEET AE215 FOR EXTERIOR FINISHES
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/1
/2
DVANLOON
Image
DVANLOON
Image
DVANLOON
TYPE 100
3' - 4"
TYPE 102 TYPE 105 TYPE 106
5' - 7" 7' - 2" 3' - 5 1/2"
TYPE 200/ 300
3' - 4"
TYPE 202/ 302 TYPE 205/ 305 TYPE 206/ 306
5' - 7" 7' - 2" 3' - 5 1/2"
TYPE 400 TYPE 404
" 3
3' - 4"
13' - 8"
IP-1, TYP.IP-1
GL3, TYP.
GL1, TYP.
TYPE W1
5' - 0"
2" 2"
FIRE RATED
GLAZING
NOTE: SEE F12/AE409 FOR
WALL ELEVATION
GL3, TYP.
GL1, TYP.
TYPE 401
/2
F
V
3' - 4" FV.
/2
TYPE 403
/2
F V
5' - 7" FV.
IP-2
IP-2
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
S A
V A
N N
A H
D
IS
T R
IC
T
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
S A
V A
N N
A H
G
E O
R G
IA
JO
N
E S
F R
A N
K
LI
N R
D , S
U
IT
E
R A
LE
IG
H , N
C
-3
(9
1-
(9
1-
F
A X
LI
C
E N
S E
F
-0
F O
R T
B E
N N
IN
G
G
A B
U
IL
D
IN
G
T
R A
IN
E
E B
A R
R A
C K
S U
P G
R A
D E
P R
O G
R
U P
P
H A
S E
F
Y P
N
FOR OFFICIAL USE ONLY
AE602
D O
O R
W
IN
D
O W
A N
D L
O U
V E
R S
C H
E D
U L E
S
Z K
A S
K Y
D V
A N
L O
O N
K B
R O
D B
E R
K B
R O
D B
E R
J U
L Y
W H
N B
- 7 -1
-2
C
A T
E G
O R
Y C
O D
E
F
IL
E N
A M
E A
E .D
W G
R E
A D
Y T
O A
D V
E R
T
IS
E
R T
A
DOOR SCHEDULE -LEVEL 03 & LEVEL 04
DOOR
ID
ROOM NAME
ROOM
NUMBE
R
DOOR HARDWARE
HEADING
NO.
FRAME
REMARKS
SIZE TYPE MAT'L CLASS PERFORMANCE FINISH COATING RATING GLAZING ACCOUST.
MAT'L FINISH COATING TYPE
DETAIL
HEAD JAMB THRESHOLD
3RD FLOOR
B311 ELEC. RM B311 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
B327-E CORR B327 3' - 4" x 7' - 6" x 0' - 1 3/4" P HM PNT 1 AL PRE. FIN. 4 DH1/AE607; DH1a/AE607 DJ1/AE607 T1/AE607 10
B328 JANITOR B328 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 9 HM PNT 2 DH3/AE607 DJ3/AE607 -
B329
ELEVATOR
CONTROLLER
B329 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2
DH3/AE607 DJ4/AE607
B330-E VESTIBULE B330 3' - 4" x 7' - 6" x 0' - 1 3/4" P HM PNT 1 AL PRE. FIN. 5 DH1/AE607; DH1b/AE607 DJ5/AE607 T1/AE607 10
B331 LAUNDRY B331 3' - 0" x 7' - 0" x 0' - 2" N HM PNT 45 MIN. GL5 9 HM PNT 2 DH3/AE607 DJ3/AE607 - 4
B332 RESTROOM B332 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 20 MIN. 10 HM PNT 1 DH3/AE607 DJ3/AE607 -
B333 STOR. B333 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
B334 TELECOM B334 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
B336 STAIR 1 B336 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10
C313 LOUNGE C313 6' - 0" x 7' - 0" x 0' - 2" FG HM PNT 20 MIN. GL5 13 HM PNT 3A DH3/AE607 DJ3/AE607 - 1, 4
C330 LAUNDRY C330 3' - 0" x 7' - 0" x 0' - 2" N HM PNT 45 MIN. GL5 9 HM PNT 2 DH3/AE607 DJ3/AE607 - 4
C331 LOUNGE C331 6' - 0" x 7' - 0" x 0' - 2" FG HM PNT 20 MIN. GL5 13 HM PNT 3A DH3/AE607 DJ3/AE607 - 1, 4
C338 CORR C338 3' - 0" x 7' - 0" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH3/AE607 DJ3/AE607 - 6, 8
C338-O CORR C338 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - - - - 0 - - - 9
C340-E CORR C340 6' - 0" x 7' - 6" x 0' - 1 3/4" P HM PNT 2 AL PRE. FIN. 6 DH1/AE607; DH1b/AE607 DJ5/AE607 T1/AE607 1, 10
C341 JANITOR C341 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 9 HM PNT 2 DH3/AE607 DJ3/AE607 -
C342 RESTROOM C342 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 20 MIN. 10 HM PNT 1 DH3/AE607 DJ3/AE607 -
C343 ELEC RM C343 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
C344 STOR. C344 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
C345 TELECOMM C345 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
C346 STAIR 3 C346 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10
C347-O CORR C347 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - - - - 0 - - - 9
C348-E CORR C348 3' - 4" x 7' - 6" x 0' - 1 3/4" P HM PNT 1 AL PRE. FIN. 4 DH1/AE607; DH1a/AE607 DJ1/AE607 T1/AE607 10
C349-O CORR C349 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - - - - 0 - - - 9
C350-E LOBBY C350 6' - 0" x 7' - 6" x 0' - 1 3/4" P HM PNT 2 AL PRE. FIN. 6 DH1/AE607; DH1b/AE607 DJ5/AE607 T1/AE607 1, 10
C352 RESTROOM C352 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 20 MIN. 10 HM PNT 1 DH3/AE607 DJ3/AE607 -
C353 ELEC RM C353 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
C354 JC C354 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 9 HM PNT 2 DH3/AE607 DJ3/AE607 -
C355 TELECOMM C355 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
C357 LAUNDRY C357 3' - 0" x 7' - 0" x 0' - 2" N HM PNT 45 MIN. GL5 9 HM PNT 2 DH3/AE607 DJ3/AE607 - 4
C358 STOR. C358 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -
C359 STAIR 2 C359 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10
C360-O CORR C360 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - - - - 0 - - - 9
C361 CORR C361 3' - 0" x 7' - 0" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH3/AE607 DJ3/AE607 - 6, 8
C361-E CORR C361 3' - 4" x 7' - 6" x 0' - 1 3/4" P HM PNT 1 AL PRE. FIN. 4 DH1/AE607; DH1a/AE607 DJ1/AE607 T1/AE607 10
4TH FLOOR/ ATTIC
B401 ATTIC B401 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH2/AE607 DJ2/AE607 -
B410 MECHANICAL RM B410 6' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. STC 50 13 HM PNT 3A DH2/AE607 (SIM) DJ2/AE607 (SIM) - 1, 12
B410-1 ATTIC B402 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH2/AE607 DJ2/AE607 -
B430 STORAGE RM B430 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 8 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10
B430-C CLOSET 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 6 HM PNT 1 DH4/AE607 DJ4/AE607 -
C401 ATTIC C401 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH2/AE607 DJ2/AE607 -
C401-1 ATTIC C401 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 8 HM PNT 2 DH2/AE607 DJ2/AE607 -
C402 ATTIC C402 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH2/AE607 DJ2/AE607
C403 ATTIC C403 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH2/AE607 DJ2/AE607 -
C440 MECHANICAL RM C440 6' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. STC 50 13 HM PNT 3A DH2/AE607 (SIM) DJ2/AE607 (SIM) - 1, 12
C445 STORAGE RM C445 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 8 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10
C445-C CLOS. 2' - 6" x 7' - 0" x 0' - 2" F WD STAIN 6 HM PNT 1 DH4/AE607 DJ4/AE607 -
C450 MECHANICAL RM C450 6' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. STC 50 13 HM PNT 3A DH2/AE607 (SIM) DJ2/AE607 (SIM) - 1, 12
C450-1 ATTIC C402 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH2/AE607 DJ2/AE607 -
C452 STORAGE RM C452 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 8 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10
C452-C CLOS. 2' - 6" x 7' - 0" x 0' - 2" F WD STAIN 6 HM PNT 1 DH4/AE607 DJ4/AE607 -
WINDOW SCHEDULE
WINDOW
TYPE
GLAZING MAT'L FINISH ACOUSTCS
DETAIL
REMARKS COUNT
HEAD JAMB SILL
1ST FLOOR
100 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH1/AE605 & WH4/AE606 WJ1/AE605 & WJ4/AE606 WS1/AE605 & WS4/AE606 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 41
102 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH4/AE606 WJ4/AE606 WS4/AE606 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 8
105 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH2/AE605 WJ2/AE605 WS2/AE605 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 19
106 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH2/AE605 & WH4/AE606 WJ2/AE605 & WJ4/AE606 WS2/AE605 & WS4/AE606 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 33
W1 GL5 HM PNT INTERIOR GLAZING, OFFICER'S LOUNGE 1
2ND FLOOR
200 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH1/AE605 & WH4/AE606 WJ1/AE605 & WJ4/AE606 WS1/AE605 & WS4/AE606 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 44
202 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH4/AE606 WJ4/AE606 WS4/AE606 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 8
205 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH2/AE605 WJ2/AE605 WS2/AE605 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 19
206 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH2/AE605 & WH4/AE606 WJ2/AE605 & WJ4/AE606 WS2/AE605 & WS4/AE606 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 33
3RD FLOOR
300 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH1/AE605 & WH4/AE606 WJ1/AE605 & WJ4/AE606 WS1/AE605 & WS4/AE606 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 44
302 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH4/AE606 WJ4/AE606 WS4/AE606 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 8
305 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH2/AE605 WJ2/AE605 WS2/AE605 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 19
306 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH2/AE605 & WH4/AE606 WJ2/AE605 & WJ4/AE606 WS2/AE605 & WS4/AE606 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 33
4TH FLOOR/ ATTIC
400 INSULATED PANEL AL PRE. FIN. WH3/AE605 WJ3/AE605 WS3/AE605 26
404 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH3/AE605 WJ3/AE605 WS3/AE605 32
0 2' 4' 8' 12'
1/4" = 1'-0"
WINDOW TYPES
DOOR SCHEDULE - TYPICAL UNITS
DOOR
ID
ROOM NAME
DOOR HARDWARE
HEADING
NO.
FRAME
REMARKS COUNT
SIZE TYPE MAT'L CLASS PERFORMANCE FINISH COATING RATING GLAZING ACCOUST. MAT'L. FINISH COATING TYPE
DETAIL
HEAD JAMB THRESHOLD
xxxx-A UNIT 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 20 MIN. STC 50 3 HM PNT 1 DH3/AE607 DJ3/AE607 - 5, 12 161 xxxx-B BATHROOM 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 4 HM PNT 1 DH4/AE607 DJ4/AE607 T2/AE607 161 xxxx-C CLOSET 7' - 0" x 7' - 0" x 0' - 2" F WD STAIN 5 - PNT N/A DH7/AE608 DJ7/AE608 - 7 96 xxxx-D CLOSET 7' - 0" x F WD STAIN 5 - PNT N/A DH7/AE608 DJ7/AE608 - 7 64 xxxx-F CLOSET 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 6 HM PNT 1 DH4/AE607 DJ4/AE607 - 1
1/4" = 1'-0"
LOUVER TYPES
LOUVER SCHEDULE
WINDOW
TYPE
GLAZING MAT'L FINISH ACOUSTCS
DETAIL
REMARKS COUNT
HEAD JAMB SILL
4TH FLOOR/ ATTIC
401 N/A AL PRE. FIN. LH1/AE606 LJ1/AE606 LS1/AE606 DRAINABLE METAL LOUVERS. FOR FINISH SEE AE215 BUILDING EXTERIOR FINISHES TABLE 2
403 N/A AL PRE. FIN. LH1/AE606 LJ1/AE606 LS1/AE606 DRAINABLE METAL LOUVERS. FOR FINISH SEE AE215 BUILDING EXTERIOR FINISHES TABLE 2
GENERAL NOTES - WINDOW SCHEDULE:
A. PROVIDE FULL SPANDREL GLAZING FOR WINDOWS IN
TELECOMM ROOMS ON BALCONY SIDE ONLY. SEE FLOOR
PLANS.
B. PROVIDE FULL SPANDREL GLAZING FOR WINDOW ADJACENT
TO SHOWER STALL IN LOCKER ROOM (WOMEN) C133.
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/1
/2
DVANLOON
Image
DVANLOON
Image
DVANLOON
SEALANT W/ BACKER ROD
NEW FLASHING WITH
STAINLESS STEEL DRIP EDGE.
DO NOT BRIDGE GAPS WITH
SUBSTRATE
INSULATED GLAZING UNIT
NEW ALUMINUM WINDOW
SYSTEM
EXISTING STONE WINDOW SILL
EXISTING MASONRY WALL. FACE
BRICK ON FIRST FLOOR AND
TOWERS. STUCCO ON SECOND
AND THIRD FLOORS
SECURE WINDOW FRAME TO
STRUCTURAL STUDS
SOLID SURFACE
WINDOW SILL
5/8" TYPE X GYPSUM BOARD
SEALANT WITH
BACKER ROD
1" GAP/ MTL STUD OFFSET
FROM EXISTING WALL
2 1/2" MTL STUDS AT 24" O.C.
TYPE WS1
STREET SIDE
TREATED WOOD SHIM AND
BLOCKING AS REQUIRED
1"
2" CLOSED CELL SPRAY FOAM
URETHANE AIR BARRIER
INSULATION TO FILL 1" GAP
CONTINUOUS BEHIND MTL
STUDS AND 1" OF STUD SPACE
PROVIDE SEALANT
AT PERIMETER AS
REQUIREDFLUID APPLIED AIR
BARRIER
3/4"
2 1/2"
TYPE WS2
BALCONY SIDE
SOLID SURFACE
WINDOW SILL
NEW ALUMINUM
WINDOW SYSTEM
INSULATED GLAZING UNIT
SEALANT WITH
BACKER ROD
5/8" TYPE X GYPSUM
BOARD
2 1/2" MTL STUDS AT 24" O.C.
2" CLOSED CELL SPRAY FOAM
URETHANE AIR BARRIER
INSULATION TO FILL 1" GAP
CONTINUOUS BEHIND MTL
STUDS AND 1" OF STUD SPACE
EXISTING PAINTED
STUCCO, PATCH AND
REPAIR AS NEEDED
1"
3/4"
PROVIDE SEALANT AT
PERIMETER AS
REQUIRED
1" GAP/ MTL STUD OFFSET
FROM EXISTING WALL
FLUID APPLIED AIR
BARRIER
SECURE WINDOW FRAME
TO STRUCTURAL STUDS
TYPE WS3
STREET SIDE (ATTIC)
INTERIOR EXTERIOR
SEALANT WITH
BACKER ROD
NEW ALUMINUM
WINDOW SYSTEM
FLASHING WITH
STAINLESS STEEL DRIP
EDGE
SEALANT WITH
BACKER ROD
EXISTING
FLOOR SLAB
TREATED WOOD SHIM AND
BLOCKING AS REQUIRED
EXISTING STUCCO WALL
PATCH AND REPAIR AS
REQUIRED. PAINTED
NEW ALUMINUM
WINDOW SYSTEM
INSULATED
GLAZING UNIT
SECURE WINDOW FRAME
TO STRUCTURAL STUDS
2 1/2" MTL STUDS
AT 24" 0.C.
5/8" TYPE X
GYPSUM BOARD
SEALANT WITH
BACKER ROD
1" GAP/ MTL STUD OFFSET
FROM EXISTING WALL
FLASHING WITH STAINLESS
STEEL DRIP EDGE.
1' - 0" FV.1"
2" CLOSED CELL SPRAY FOAM
URETHANE AIR BARRIER
INSULATION TO FILL 1" GAP
CONTINUOUS BEHIND MTL STUDS
AND 1" OF STUD SPACE
ROLLER SHADE, SEE
TYPICAL DETAIL L9/AE605
PROVIDE SEALANT AT
PERIMETER AS REQUIRED
FLUID APPLIED AIR
BARRIER
CONTINUOUS BLOCKING
AS NEEDED TO MOUNT
ROLLER SHADE
TYPE WH2
BALCONY SIDE
EXISTING CONCRETE
BEAM, PAINTED
SEALANT W/
BACKER ROD
NEW ALUMINUM
WINDOW SYSTEM
INSULATED
GLAZING UNIT
FASTENERS THROUGH BACK
OF BRACKET FOR JAMB
MOUNT OPTION
PROVIDE SEALANT AT
PERIMETER AS REQUIRED
TREATED WOOD
SHIM AND BLOCKING
AS NEEDED
SECURE WINDOW
FRAME TO STUDS
1" GAP/ MTL STUD OFFSET
FROM EXISTING WALL
2" CLOSED CELL SPRAY FOAM
URETHANE AIR BARRIER
INSULATION TO FILL 1" GAP
CONTINUOUS BEHIND MTL
STUDS AND 1" OF STUD SPACE
1 5/8" MTL STUDS
AT 24" O.C.
FLUID APPLIED
AIR BARRIER
5/8" TYPE-X
GYPSUM BOARD
1' - 3" FV. 1"
ROLLER SHADE,
TYPICAL
TYPE WH3
BALCONY SIDE (ATTIC)
INTERIOR
EXTERIOR
EXISTING CONCRETE
BEAM, PAINTED
5/8" TYPE X GYPSUM BOARD
SEALANT AT PERIMETER
AS REQUIRED
NEW WINDOW
SYSTEM AS
SCHEDULED
SEALANT WITH
BACKER ROD,
BOTH SIDES
LTTR-11.4 2"
POLYSOCYANURATE RIGID
INSULATION ADHERED TO
STRUCTURE
1 5/8" MTL STUDS AT 24" O.C.
SHIM AND BLOCKING
AS REQUIRED
FV.
TYPE WJ1
STREET SIDE
TYPE WJ2
BALCONY SIDE
INTERIOR
EXTERIOR
EXISTING WALL,
PAINTED
5/8" TYPE X
GYPSUM BOARD
PROVIDE SEALANT AT
PERIMETER AS REQUIRED
NEW WINDOW SYSTEM AS
SCHEDULED
SEALANT W/ BACKER ROD
TYPE WJ3
ATTIC
LTTR-11.4 2"
POLYSOCYANURATE RIGID
INSULATION ADHERED TO
STRUCTURE
EXISTING MASONRY WALL. FACE
BRICK ON FIRST FLOOR AND
TOWERS, STUCCO ON SECOND AND
THIRD FLOORS
SEALANT WITH BACKER ROD
NEW ALUMINUM WINDOW
SYSTEM
INSULATED GLAZING UNIT
3/4" SOLID SURFACE
WINDOW SILL
2 1/2" MTL STUDS AT 24" O.C.
5/8" TYPE X GYPSUM BOARD
PROVIDE SEALANT AT
PERIMETER AS REQUIRED
EXISTING PAINTED
STUCCO, PATCH AND
REPAIR AS NEEDED
SEALANT WITH
BACKER ROD
NEW ALUMINUM
WINDOW SYSTEM
INSULATED
GLAZING UNIT
PROVIDE SEALANT AT
PERIMETER AS REQUIRED
3/4" SOLID SURFACE
WINDOW SILL
1 5/8" MTL STUD AT 24" O.C.
SECURE WINDOW FRAME TO
STRUCTURAL STUDS
FLUID APPLIED AIR BARRIER
F V
/4
1" GAP/ MTL STUD
OFFSET FROM
EXISTING WALL
2" CLOSED CELL SPRAY
FOAM URETHANE AIR
BARRIER INSULATION TO
FILL 1" GAP CONTINUOUS
BEHIND MTL STUDS AND
1" OF STUD SPACE
TREATED WOOD
SHIM AND BLOCKING
AS REQUIRED
1" GAP/ MTL STUD OFFSET
FROM EXISTING WALL
2" CLOSED CELL SPRAY FOAM URETHANE
AIR BARRIER INSULATION TO FILL 1" GAP
CONTINUOUS BEHIND MTL STUDS AND 1"
OF STUD SPACE
2 1/2" MTL STUDS AT 24" O.C.
SECURE WINDOW FRAME TO
STRUCTURAL STUDS
/4
FLUID APPLIED AIR BARRIER
5/8" TYPE X GYPSUM BOARD
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
S A
V A
N N
A H
D
IS
T R
IC
T
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
S A
V A
N N
A H
G
E O
R G
IA
JO
N
E S
F R
A N
K
LI
N R
D , S
U
IT
E
R A
LE
IG
H , N
C
-3
(9
1-
(9
1-
F
A X
LI
C
E N
S E
F
-0
F O
R T
B E
N N
IN
G
G
A B
U
IL
D
IN
G
T
R A
IN
E
E B
A R
R A
C K
S U
P G
R A
D E
P R
O G
R
U P
P
H A
S E
F
Y P
N
FOR OFFICIAL USE ONLY
AE605
W
IN
D O
W D
E T
A
IL
S
Z K
A S
K Y
D V
A N
L O
O N
K B
R O
D B
E R
K B
R O
D B
E R
J U
L Y
W H
N B
- 7 -1
-2
C
A T
E G
O R
Y C
O D
E
F
IL
E N
A M
E A
E .D
W G
R E
A D
Y T
O A
D V
E R
T
IS
E
R T
A
3" = 1'-0"A1
WINDOW SILL DETAL
3" = 1'-0"A9
WINDOW SILL DETAIL
0 0.125' 0.25' 0.5' 0.75'
3" = 1'-0"A15
WINDOW SILL DETAIL
3" = 1'-0"L1
WINDOW HEAD DETAIL
3" = 1'-0"L9
WINDOW HEAD AND TYPICAL ROLLER
SHADE DETAIL
3" = 1'-0"L15
WINDOW HEAD DETAIL
3" = 1'-0"F1
WINDOW JAMB DETAILS
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/1
/2
DVANLOON
Image
DVANLOON
Image
DVANLOON
TYPE WS4
STREET SIDE SHOWN (BALCONY SIDE, SIM)
3/4"
1"
INSULATED
GLAZING
NEW ALUMINUM
WINDOW
SYSTEM
NEW FLASHING
WITH STAINLESS
STEEL DRIP EDGE.
DO NOT BRIDGE
GAPS WITH
SUBSTRATE
SEALANT WITH
BACKER ROD
EXISTING STONE
WINDOW SILL
TREATED WOOD
SHIM AND
BLOCKING AS
NEEDED
EXISTING
MASONRY WALL
WITH FACE BRICK
PROVIDE SEALANT AT
PERIMETER AS REQUIRED
SECURE
WINDOW FRAME
TO STRUCTURAL
MTL STUDS
FLUID APPLIED
AIR BARRIER
SOLID SURFACE
WINDOW SILL
SEALANT
2 1/2" MTL STUDS
AT 24" O.C.
1" GAP/ MTL STUD
OFFSET FROM
EXISTING WALL
2" CLOSED CELL SPRAY
FOAM URETHANE AIR
BARRIER INSULATION TO
FILL 1" GAP CONTINUOUS
BEHIND MTL STUDS AND
1" OF STUD SPACE
TYPE WH4
STREET SIDE SHOWN (BALCONY SIDE, SIM)
1"
2" CLOSED CELL SPRAY
FOAM URETHANE AIR
BARRIER INSULATION
TO FILL 1" GAP
CONTINUOUS BEHIND
MTL STUDS AND 1" OF
STUD SPACE
1" GAP/ MTL STUD
OFFSET FROM
EXISTING WALL
5/8" TYPE-X
GYPSUM BOARD
ROLLER SHADE,
SEE TYPICAL
DETAIL L9/AE605
PROVIDE SEALANT
AT PERIMETER AS
REQUIRED
FACE BRICK
EXISTING STEEL
LINTEL PAINTED
SEALANT WITH
BACKER ROD
NEW FLASHING
WITH STAINLESS
STEEL DRIP EDGE.
DO NOT BRIDGE
GAPS WITH
SUBSTRATE
TREATED WOOD
SHIM AND
BLOCKING AS
REQUIRED
SECURE WINDOW
FRAME TO
STRUCTURAL STUDS
FLUID APPLIED
AIR BARRIER
2 1/2" MTL STUDS AT 24" O.C.
MUNTIN
INTERIOR
EXTERIOR
/8
NEW WINDOW SYSTEM
AS SCHEDULE
HORIZONTAL & VERTICAL
MULLION
TYPE WJ4
SEALANT WITH BACKER ROD
NEW ALUMINUM WINDOW
SYSTEM
INSULATED GLAZING UNIT
SOLID SURFACE WINDOW
SILL
2 1/2" MTL STUDS AT 24" O.C.
5/8" TYPE X GYPSUM BOARD
PROVIDE SEALANT AT
PERIMETER AS REQUIRED
SECURE WINDOW FRAME TO
STRUCTURAL STUDS
FLUID APPLIED AIR BARRIER
/4
1" GAP/ MTL STUD
OFFSET FROM
EXISTING WALL
2" CLOSED CELL SPRAY FOAM
URETHANE AIR BARRIER
INSULATION TO FILL 1" GAP
CONTINUOUS BEHIND MTL
STUDS AND 1" OF STUD SPACE
TREATED WOOD
SHIM AND BLOCKING
AS REQUIRED
F V
EXISTING
MASONRY WALL
WITH FACE BRICK
2"
EXISTING STEEL
LINTEL
EXISTING
MASONRY WALL
W/ FACE BRICK,
PATCH AND FINISH
AS REQUIRED
4" FV.
SEALANT AT
PERIMETER OF
FRAME
SHIM AS REQUIRED
SECURITY GRILLE
ANCHORED TO
LOUVER
FRAME AS
SCHEDULED
5/8" TYPE X
GYPSUM BOARD
LTTR-11.4 2"
POLYSOCYANURATE
RIGID INSULATION
ADHERED TO
STRUCTURE
1 5/8" MTL STUDS
AT 24" O.C.
NEW FLASHING WITH
STAINLESS STEEL
DRIP EDGE. DO NOT
BRIDGE GAPS WITH
SUBSTRATE
SEALANT WITH
BACKER ROD
FLUID APPLIED
AIR BARRIER
TYPE LH1
PRE-FINISHED METAL
DRAINABLE LOUVER
SECURE LOUVER
FRAME TO MASONRY
WALL AND MTL STUDS
TYPE LJ1
5/8" TYPE X
GYPSUM BOARD
LTTR-11.4 2"
POLYSOCYANURATE RIGID
INSULATION ADHERED TO
STRUCTURE
1 5/8" MTL STUDS
AT 24" O.C.
EXISTING MASONRY
WALL W/ FACE BRICK,
PATCH AND FINISH AS
REQUIRED
SEALANT WITH
BACKER ROD
PRE-FINISHED METAL
DRAINABLE LOUVER
SECURITY GRILL
ANCHORE TO LOUVER
SEALANT AT
PERIMETER OF
FRAME
FLUID APPLIED
AIR BARRIER
TREATED WOOD
SHIM AND BLOCKING
AS REQUIRED
SECURE LOUVER
FRAME TO MASONRY
WALL AND MTL STUDS
MULLION AS
INDICATED
TYPE LS1
PRE-FINISHED METAL
DRAINABLE LOUVER
2"
5/8" TYPE X
GYPSUM BOARD
LTTR-11.4 2"
POLYSOCYANURATE
RIGID INSULATION
ADHERED TO
STRUCTURE
1 5/8" MTL STUDS
AT 24" O.C.
FLUID APPLIED
AIR BARRIER
FLUID APPLIED
AIR BARRIER
SEALANT WITH
BACKER ROD
EXISTING STONE
WINDOW SILL
TREATED WOOD
SHIM AND
BLOCKING AS
NEEDED
EXISTING
MASONRY WALL
WITH FACE BRICK
NEW FLASHING WITH
STAINLESS STEEL DRIP
EDGE. DO NOT BRIDGE
GAPS WITH SUBSTRATE
SEALANT AT
PERIMETER OF FRAME
SECURITY GRILLE
ANCHORED TO LOUVER
DO NOT CAULK SILL
OF LOUVER
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
S A
V A
N N
A H
D
IS
T R
IC
T
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
S A
V A
N N
A H
G
E O
R G
IA
JO
N
E S
F R
A N
K
LI
N R
D , S
U
IT
E
R A
LE
IG
H , N
C
-3
(9
1-
(9
1-
F
A X
LI
C
E N
S E
F
-0
F O
R T
B E
N N
IN
G
G
A B
U
IL
D
IN
G
T
R A
IN
E
E B
A R
R A
C K
S U
P G
R A
D E
P R
O G
R
U P
P
H A
S E
F
Y P
N
FOR OFFICIAL USE ONLY
AE606
W
IN
D O
W
L O
U V
E R
D E
T A
IL
S
A
T T
O W
E R
S
F A
C E
B R
IC
K
Z K
A S
K Y
D V
A N
L O
O N
K B
R O
D B
E R
K B
R O
D B
E R
J U
L Y
W H
N B
- 7 -1
-2
C
A T
E G
O R
Y C
O D
E
F
IL
E N
A M
E A
E .D
W G
R E
A D
Y T
O A
D V
E R
T
IS
E
R T
A
3" = 1'-0"A1
WINDOW SILL DETAIL - TOWERS
3" = 1'-0"L1
WINDOW HEAD DETAIL - TOWERS
0 0.125' 0.25' 0.5' 0.75'
3" = 1'-0"L15
TYPICAL MULLION & MUNTIN DETAILS
3" = 1'-0"F1
WINDOW JAMB DETAIL - TOWERS
3" = 1'-0"L8
DOOR HEAD DETAILS
3" = 1'-0"F8
DOOR HEAD DETAILS
3" = 1'-0"A8
DOOR HEAD DETAILS
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/1
/2
DVANLOON
Image
DVANLOON
Image
DVANLOON
A. 20 GA STUDS AND BLOCKING IS REQUIRED WHERE WALL
HUNG CABINETS, COUNTERTOPS, AND APPLIANCES (IE: TV,
SMART BOARD, TACKBOARD, ETC.) OCCUR. OTHERWISE
GAUGE IS TO MEET MINIMUM PERFORMANCE OF WALL.
REFER TO AF, IF, AND MPE SERIES SHEETS FOR LOCATIONS
OF APPURTENANCES - TYPICAL
B. PROVIDE HORIZONTAL BRACING AS REQUIRED ABOVE
CEILING FOR 25 GA METAL STUDS SPACED 24 INCHES OC
THAT EXCEED LIMITING HEIGHT FACTOR PER MFR TABLES -
TYPICAL
C. ALL GYPSUM BOARD IS TO BE OFFSET 1/2" MIN FROM TOP
AND BOTTOM OF FLOOR SLABS, UNO - TYPICAL
D. AT SOUND ATTENUATION PARTITIONS, COORDINATE ALL
DUCT, CONDUITS, PIPES, AND CABLE TRAY PENETRATIONS.
PROVIDE ACOUSTICAL SEALANT AT PENETRATION
PERIMETER - TYPICAL
E. AT SOUND ATTENUATION PARTITIONS, SEAL PARTITIONS AT
BOTTOM (FLOOR SLAB) AND TOP (BOTTOM OF SLAB) -
TYPICAL
F. AT FIRE RATED PARTITIONS, COORDINATE DAMPER
LOCATIONS, AND ALL DUCT, CONDUITS, PIPES, AND CABLE
TRAY PENETRATIONS. PROVIDE FIRE STOPPING MATCHING
PARTITION RATING AT PENETRATION PERIMETERS - TYPICAL
G. AT CORRIDORS, STORAGE ROOMS, AND LAUNDRY ROOMS,
PROVIDE FULL HEIGHT 5/8" IMPACT, MOLD AND MILDEW
RESISTANT GYPSUM BOARD - TYPICAL
H. SEE STRUCTURAL SHEET S-503 FOR ADDITIONAL PARTITION
DETAILS AND INFORMATION
PARTITION TYPES NOTES:
SECTION
PLAN
FIRE RATING:
DESCRIPTION:
STC RATING:
UL DESIGN:
REMARKS:
PARTITION TYPE
1/2 HR RATED
CHASE WALL
1) FIRE STOP AND ACOUSTICAL SEAL
ALL PENETRATIONS; 2) SEE INTERIOR
ELEVATIONS FOR TILE HEIGHTS
1"=1'-0"
CEILING AS
SCHEDULED
BOTTOM
EXIST. SLAB
CERAMIC TILE
BASE AS
SCHEDULED
FINISH FLOOR AS
SCHEDULED
3-5/8" METAL STUDS
25 GA AT 16" OC
3-1/2" SOUND
ATTENUATION FIRE
BATT (SAFB)
5/8" CEMENTITIOUS
BACKER BD
CONT FIRE SAFING
SEALANT AT TOP &
BOTTOM
CONT
RUNNERS - SLIP
CONNECTION
CERAMIC WALL TILE
AS SCHEDULED
SEE FLOOR PLANS
VARIES
S E
E F
L O
O R
P L A
N S
V A
R
IE
S
3-5/8" METAL STUDS
25 GA AT 16" OC
3-1/2" SOUND
ATTENUATION
FIRE BATT (SAFB)
5/8" CEMENTITIOUS
BACKER BD CERAMIC WALL
TILE AS
SCHEDULED
CONT RUNNER
CEILING AS
SCHEDULED
BOTTOM
EXIST. SLAB
BASE AS
SCHEDULED
FINISH FLOOR AS
SCHEDULED
SECTION
PLAN
4" C-H STUDS 25 GA
(400CH-34) AT 24" OC
VERTICAL
3" SOUND
ATTENUATION FIRE
BATT (SAFB)
5/8" TYPE X HIGH IMPACT
MOLD AND
MILDEW RESISTANT GYP
BD
CONT FIRE SAFING
SEALANT AT TOP &
BOTTOM
CONT J-RUNNERS
FIRE RATING:
DESCRIPTION:
STC RATING:
UL DESIGN:
REMARKS:
PARTITION TYPE
1 HR RATED
SHAFT WALL
U415
4" C-H STUD, 4" J-STUD
1"=1'-0"
T O
/8
M
IN
M A
X
SHAFT
CONT J-RUNNERS
1" GYP LINER
PANEL
3" SOUND
ATTENUATION FIRE
BATT (SAFB)
5/8" TYPE X HIGH IMPACT
MOLD AND
MILDEW RESISTANT GYP
BD
1" GYP LINER
PANEL
4" C-H STUDS 25 GA
(400CH-34) AT 24" OC
VERTICAL
SHAFT
CEILING AS
SCHEDULED
BOTTOM
EXIST. SLAB
BASE AS
SCHEDULED
FINISH FLOOR AS
SCHEDULED
SECTION
PLAN
3-5/8" METAL STUDS
25 GA AT 24" OC
5/8" TYPE X HIGH
IMPACT MOLD AND
MILDEW RESISTANT
GYP BD
CONT SEALANT AT
BOTTOM
CONT RUNNERS -
SLIP CONNECTION
FIRE RATING:
DESCRIPTION:
STC RATING:
UL DESIGN:
REMARKS:
PARTITION TYPE
METAL STUD WALL, (1) LAYER GYP BD
3-5/8" METAL STUDS
1"=1'-0"
3-5/8" METAL STUDS
25 GA AT 24" OC
5/8" TYPE X HIGH IMPACT
MOLD AND
MILDEW RESISTANT GYP
BD
CONT RUNNER
M
IN6
FIRE RATING:
DESCRIPTION:
STC RATING:
UL DESIGN:
REMARKS:
PARTITION TYPE
09A
METAL STUD WALL, (1) LAYER GYP BD
3-5/8" METAL STUDS, CERAMIC WALL
TILE
1"=1'-0"
09: 5/8" TYPE X HIGH
IMPACT MOLD AND
MILDEW RESISTANT GYP
BD
09A: 5/8" CEMENTITIOUS
BACKER BD
09A: CERAMIC WALL
TILE AS SCHEDULED
09: BASE AS
SCHEDULED
09A: CERAMIC BASE
AS SCHEDULED
09: 5/8" TYPE X HIGH
IMPACT MOLD AND
MILDEW RESISTANT GYP
BD
09A: 5/8" CEMENTITIOUS
BACKER BD
09A: CERAMIC WALL
TILE AS SCHEDULED
CEILING AS
SCHEDULED
BOTTOM
EXIST. SLAB
BASE AS
SCHEDULED
FINISH FLOOR AS
SCHEDULED
SECTION
PLAN
2-1/2" COLD FORMED
METAL STUDS 25 GA
AT 24" OC
5/8" TYPE X HIGH IMPACT
MOLD AND MILDEW
RESISTANT GYP BD
CONT SEALANT AT
TOP & BOTTOM AND
WALL PERIMETER
CONT RUNNERS -
SLIP CONNECTION
FIRE RATING:
DESCRIPTION:
STC RATING:
UL DESIGN:
REMARKS:
PARTITION TYPE
2-1/2" METAL STUD WALL FURRING
EXTERIOR PERIMETER WALL
1"=1'-0"
CONT RUNNER
EXIST EXTERIOR
PERIMETER WALL
ASSEMBLY
2-1/2" COLD FORMED
METAL STUDS 25 GA
AT 24" OC
5/8" TYPE X HIGH
IMPACT MOLD AND
MILDEW
RESISTANT GYP BD
EXIST EXTERIOR
PERIMETER WALL
ASSEMBLY
CLOSED CELL SPRAY
FOAM URETHANE AIR
BARRIER INSULATION
1"
2" MIN
CLOSED CELL SPRAY
FOAM URETHANE AIR
BARRIER INSULATION
M
IN
PROVIDE HORIZONTAL
BRACING AS REQUIRED
CEILING AS
SCHEDULED
BOTTOM
EXIST. SLAB
11: BASE AS SCHEDULED
11A: CERAMIC BASE AS
SCHEDULED
FINISH FLOOR AS
SCHEDULED
SECTION
PLAN
3-5/8" METAL STUDS
25 GA AT 24" OC
11: 5/8" TYPE X HIGH
IMPACT MOLD AND
MILDEW RESISTANT GYP
BD
11A: 5/8" CEMENTITIOUS
BACKER BD
CONT SEALANT AT
BOTTOM
CONT RUNNERS -
SLIP CONNECTION
FIRE RATING:
DESCRIPTION:
STC RATING:
UL DESIGN:
REMARKS:
PARTITION TYPE
METAL STUD CHASE WALL
3-5/8" METAL STUDS
1"=1'-0"
CONT RUNNER
EXISTING WALL
3-5/8" METAL STUDS
25 GA AT 24" OC
EXIST WALL
SEE FLOOR PLAN
VARIES
S E
E F
L O
O R
P L
A N
V A
R
IE
S
M
IN6
FIRE RATING:
DESCRIPTION:
STC RATING:
UL DESIGN:
REMARKS:
PARTITION TYPE
11A
METAL STUD CHASE WALL
3-5/8" METAL STUDS, CERAMIC WALL
TILE
1"=1'-0"
11A: CERAMIC WALL
TILE AS SCHEDULED
11: 5/8" TYPE X HIGH
IMPACT MOLD AND
MILDEW RESISTANT GYP
BD
11A: 5/8" CEMENTITIOUS
BACKER BD
11A: CERAMIC WALL
TILE AS SCHEDULED
CEILING AS
SCHEDULED
BOTTOM
EXIST. SLAB
CERAMIC BASE
AS SCHEDULED
FINISH FLOOR AS
SCHEDULED
SECTION
PLAN
2-1/2" COLD FORMED
METAL STUDS 25 GA
AT 24" OC
5/8" CEMENTITIOUS
BACKER BD
CONT SEALANT AT
TOP & BOTTOM AND
WALL PERIMETER
CONT RUNNERS -
SLIP CONNECTION
FIRE RATING:
DESCRIPTION:
STC RATING:
UL DESIGN:
REMARKS:
PARTITION TYPE
2-1/2" METAL STUD WALL FURRING
EXTERIOR PERIMETER WALL W/
CERAMIC WALL TILE
1"=1'-0"
CONT RUNNER
EXIST EXTERIOR
PERIMETER WALL
ASSEMBLY
2-1/2" COLD FORMED
METAL STUDS 25 GA
AT 24" OC
5/8" CEMENTITIOUS
BACKER BD
EXIST…