This solicitation is for repair work on Building 399 Sections B and C at Fort Benning, Georgia. The scope of work includes repairs to exterior walls, windows, fire protection, interior walls, doors, interior finishes, floors, ceilings, plumbing, HVAC, building controls, electrical, communications, building information systems, site utilities, and minor parking improvements. Demolition and HAZMAT/asbestos abatement are also required. The acquisition will be awarded as a 100% competitive full and open unrestricted contract, with a price evaluation preference for HUBZone small businesses. The contract value is estimated between $25-100 million. The point of contact is Mr. Hector L. Sierra-Almedina of the Army Corps of Engineers Savannah District. Bids are due in response to Solicitation Number W912HN21B3007.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A. CONTRACTOR TO FIELD VERIFY ALL DIMENSION AND EXISTING

CONDITIONS PRIOR TO START OF CONSTRUCTION. IF ANY DISCREPANCIES

WITH CONSTRUCTION DOCUMENTS, CONTRACTOR IS TO INFORM

CONTRACTING OFFICER IN WRITING PRIOR TO START OF CONSTRUCTION.

B. CONTRACTOR IS TO PROTECT ALL EXISTING ITEMS TO REMAIN FROM

DAMAGE DURING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR

REPAIRING, AND/ OR REPLACING DAMAGED ITEMS TO REMAIN WITH

EQUAL OR BETTER, TO THEIR ORIGINAL STATE, AT NO COST TO

GOVERNMENT.

C. REPOINT LOOSE MORTAR JOINTS, REPAIR CRACKS AND DAMAGE AT ALL

EXISTING MASONRY WALLS. ALL EXTERIOR MASONRY REPAIRS SHALL

MATCH HISTORIC CHARACTER, COLOR, AND PATTERN OF EXISTING

FACADE. ALL WORK TO BE AS PER HISTORIC PRESERVATION

REQUIREMENTS. FINAL SELECTIONS TO BE APPROVED BY CONTRACTING

OFFICER.

D. CLEAN AND PATCH ALL EXISTING STUCCO. REPAIR CRACKS AND DAMAGE.

ALL EXTERIOR STUCCO REPAIRS SHALL MATCH HISTORIC CHARACTER,

COLOR, AND PATTERN OF EXISTING FACADE. ALL WORK TO BE AS PER

HISTORIC PRESERVATION REQUIREMENTS. FINAL SELECTIONS TO BE

APPROVED BY CONSTRACTING OFFICER.

E. ALL CORE DRILL LOCATIONS ARE TO BE VERIFIED BY GENERAL

CONTRACTOR (GC) PRIOR TO DRILLING. GC IS TO COORDINATE ALL FINAL

CORE DRILL LOCATIONS WITH ASSOCIATED TRADES PRIOR TO START OF

CONSTRUCTION.

F. EXISTING ROOF SYSTEM PENETRATIONS: COORDINATE DETAILS AND

CONSTRUCTION WITH MANUFACTURER AND INSTALLER OF EXISTING

ROOF SYSTEM TO AVOID LOSS OF EXISTING ROOF WARRANTY

G. CONTRACTOR TO PROVIDE BLOCKING AT ALL SURFACE (WALL, CEILING)

MOUNTED FIXTURES AND EQUIPMENT AS REQUIRED.

H. REMOVAL AND REINSTALLATION OF EXISTING GUTTERS AND

DOWNSPOUTS REQUIRED TO COMPLETE NEW WORK IS TO NOT VOID

EXISTING GUTTER AND DOWNSPOUT WARRANTIES.

I. REMOVAL AND REINSTALLATION OF EXISTING LIGHTNING PROTECTION

SYSTEM REQUIRED TO COMPLETE NEW WORK IS TO NOT VOID EXISTING

GUTTER AND DOWNSPOUT WARRANTIES.

GENERAL NOTES:

A. CONTRACTOR IS TO FIELD VERIFY ALL DIMENSIONS AND EXISTING

CONDITIONS PRIOR TO START OF EXTERIOR WALL REPAIR

B. ALL SURFACES SHOULD BE STAGED TO ALLOW FOR HANDS ON INSPECTION

AND ANY REPAIRS IF NECESSARY

C. ALL DAMAGED MASONRY JOINTS OF SECTIONS B AND C ARE TO BE

REPOINTED (TUCK POINTING). ALL DAMAGED MORTAR JOINTS ARE TO BE

GROUND-OUT AND POINTED WITH NEW MORTAR. NEW MORTAR IS TO BE THE

SAME COMPOSITION AS EXISTING MORTAR. ALSO SEE SPECIFICATIONS

SECTION 04 01 20.70

D. ALL LOOSE LIMESTONE AND BRICK TO BE REMOVED, CLEANED AND

REPOSITIONED IN PLACE

E. ALL MISSING, SPALLED, BROKEN AND CHIPPED BRICK TO BE REMOVED AND

REPLACED WITH NEW TO MATCH EXISTING. ALSO SEE BUILDING EXTERIOR

FINISHES ON SHEET AE215.

F. WHEN REPLACING MASONRY OR FILLING IN MASONRY AREAS, NEW

MASONRY IS TO BE KEYED INTO EXISTING MASONRY. USE NEW NON-

CORROSIVE ANCHORS AND/ OR TIES AS REQUIRED.

G. ALL EXTERIOR SURFACES OF SECTIONS B AND C ARE TO BE CLEANED AND

WASHED TO REMOVE GRIME. APPLY CLEAR ANTI-GRAFFITI COATING. ALSO

SEE SPECIFICATIONS SECTIONS 03 01 30 AND 04 01 20.70

H. ALL LIMESTONE WITH CHIPPING LESS THAN 3 INCHES TO BE REPAIRED WITH

COMPOSITE PATCHING/ REPAIR. COMPOSITE PATCHING TO BE DONE WITH

CEMENT TYPE PATCH MATERIAL AND TO MATCH EXISINTG STONE COLOR,

TEXTURE, AND REPLICATE EXISTING SURFACE TOOLING, AND ADHERE WELL

TO EXISTING STONE SUBSTRATE, AND IS TO NOT CAUSE DETERIORATION OF

SURROUNDING STONE(S).

I. ALL LIMESTONE WITH CHIPPING 3 INCHES AND LARGER TO BE PARTIALLY

REPLACED OR TO BE PIECED-IN WITH NATURAL OR PRECAST STONE-

DUTCHMAN REPAIR. FOR DUTCHMAN REPAIR SEE SPECIFICATIONS SECTION

04 01 20.70

J. ALL CONTROL JOINTS IN SECTIONS B AND C, BETWEEN SECTIONS A AND B

AND BETWEEN C AND D, ARE TO BE RESEALED. PREPARE SURFACES

BEFORE RESEALING. SEE SPECIFICATIONS SECTION 07 92 00

EXTERIOR WALL REPAIR NOTES:

305305

LIMESTONE OR BRICK

SURFACE SEAL FOR EPOXY

TO BE REMOVED AFTER

COMPLETED PROCEDURE

EXISTING CRACK OR

MATERIAL DEFECT

GRIND BACK EXISTING TIE.

PRIME W/ RUST INHIBITING

PAINT. FIELD VERIFY

EXISTING CONDITIONS

-GRIND SQUARE EDGE

1/2" DEEP

PRIME EXPOSED SURFACES

WITH EPOXY RESIN BINDER

DRILL-IN 3/8" DIA HILTI

ADHESIVE ANCHOR AT OLD

TIE LOCATIONS

REMOVE LOOSE PIECES

AND DEBRIS. CLEAN

SURFACES AND PREPARE

TO RECEIVE NEW FORM

EPOXY RESIN MORTAR

FORMED TO ORIGINAL

PROFILE OF SPALLED UNIT

ONLY AS NECESSARY

REPAIR JOINT AS

REQUIRED. SEE DETAIL

H5-A/AE215

REPAIR JOINT AS REQUIRED.

SEE DETAIL H5-A/AE215

EXISTING TIE. CLEAN LOOSE RUST, PREPARE

EXPOSED SURFACES, AND COAT W/ EPOXY

BENT SST 1/4" DIA ROD DOWEL.

PROVIDE MIN 2" COVER

PRIME EXPOSED SURFACES WITH

EPOXY RESIN BINDER

GRIND SQUARE EDGE 1/2" DEEP

REMOVE LOOSE PIECES AND DEBRIS.

CLEAN SURFACES AND PREPARE TO

RECEIVE NEW FORM

SINGLE-COMPONENT, CEMENTITIOUS,

MENERAL-BASED MORTAR FORMED TO

ORIGINAL PROFILE OF SPALLED UNIT ONLY AS

NECESSARY. COLOR TO MATCH EXISTING

LIMESTONE. FOLLOW CONTOURS AND PROFILE

OF ADJACENT EXISTING STONE SURFACES

A B C D

EXISTING MORTAR

W

ID

T H

RAKE OUT 2.5 TIMES

THE WIDTH , NOT

LESS THAN 1/2" NOR

LESS THAN

REQUIRED TO

EXPOSE SOUND

MORTAR

EXISTING MORTAR EXISTING MORTAR EXISTING MORTAR

EXISTING BRICK EXISTING BRICK EXISTING BRICK EXISTING BRICK

3/8" MAX LAYERS

OF POINTING

MORTAR

W

ID

T H

W

= W

5/8".

IF WIDTH IS

GREATER THAN

1/2" + BACKER

ROD DIA

3/8" MAX LAYERS

OF POINTING

MORTAR

PATCH

SPALLED

EDGES PRIOR

TO POINTING

BUILDING EXTERIOR FINISHES

APPROVED BY USACE, MATCHING SECTIONS A AND G FOR CONTINUITY OF EASTHETICS

TYPE

MARK

MATERIAL MANUFACTURER PATTERN/ SERIES SIZE COLOR NOTES & COMMENTS

EXTERIOR WALLS

FB-1

GR-2

EXTERIOR WINDOWS

MECHANICAL YARD

EXTERIOR SIGNAGE

STUCCO AT INFILL WINDOWS

LINTELS

GROUT

FACE BRICK

STUCCO

DOORS

MECHANICAL LOUVERS

CURRIES TECHNICAL MANUAL PANEL DOOR SELECTION

SHERWIN-WILLIAMS

SHERWIN-WILLIAMS

SHERWIN-WILLIAMS

CHEROKEE BRICK AND TILE

GREENHECK

ARCHITECTURAL PANELS

MATCH EXISTING CHEROKEE RED TO MATCH SECTIONS A AND G

TO MATCH SECTIONS A AND G

SEE AE601 AND AE602

P: 706-577-3009ARGOS SAHARA

SW-6006 BLACK BEAN

SW-6006 BLACK BEAN

7684 CONCORD BUFF

CLASSIC BRONZE GF108

E6 PANEL DOOR

MATCH EXISTING

MATCH EXISTING

SIGNS SHERWIN-WILLIAMS SW-6006 BLACK BEAN TO MATCH SECTIONS A AND G

SEE AG-SERIES SHEETS

PC-1 PRE-CAST MILLER-MIZE PRECAST, INC.

SHERWIN-WILLIAMS

MMPI (D)

SW-2808 ROCKWOOD DARK BROWN

LIGHT BUFF TO MATCH SECTIONS A AND G

TO MATCH SECTIONS A AND G

AT FRAMES, MULLIONS, MUNTINS. TO MATCH SECTIONS A AND G

AT OPENINGS W/ LOUVER(S). TO MATCH SECTIONS A AND G

TO MATCH SECTIONS A AND G

ALSO SEE DOOR SCHEDULE LEGEND

STANDARD KYNAR

INSULATED PANEL

1" INSULATED PANEL

GLAZING

SPANDREL GLASS

CAULK

CAST STONE SILL

MAPES

MAPES

SOLARBAN

MAPES

PECORA SEALANTS

BELLAVANT

ARCHITECTURAL PANELS

ARCHITECTURAL PANELS

MANSARD BROWN

DARK BRONZE

SOLARBRONZE #2

DARK BRONZE

CLASSIC BRONZE 046

PATINA DSF1-203

GATES

IP-1

IP-2

US Army Corps of Engineers ®

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

E O

R G

IA

JO

N

E S

F R

A N

K

LI

N R

D , S

U

IT

E

R A

LE

IG

H , N

C

-3

(9

1-

(9

1-

F

A X

LI

C

E N

S E

F

-0

F O

R T

B E

N N

IN

G

G

A B

U

IL

D

IN

G

T

R A

IN

E

E B

A R

R A

C K

S U

P G

R A

D E

P R

O G

R A

M

(T B

U P

P

H A

S E

F

Y P

N

FOR OFFICIAL USE ONLY

AE215

E X

T E

R

IO

R F

IN

IS

H E

S A

N D

W A

L L R

E P

A

IR

D E

T A

IL

S

Z K

A S

K Y

D V

A N

L O

O N

K B

R O

D B

E R

K B

R O

D B

E R

J U

L Y

W H

N B

- 7 -1

-2

C

A T

E G

O R

Y C

O D

E

F

IL

E N

A M

E A

E .D

W G

R E

A D

Y T

O A

D V

E R

T

IS

E

R T

A

KEYNOTES

008 EXISTING MASONRY WALL. PATCH, REPAIR AS REQUIRED. FINISH AS

INDICATED. SEE SHEET AE215 FOR ADDITIONAL INFORMATION - TYPICAL

009 EXISTING STUCCO WALL. PATCH, REPAIR AS REQUIRED AND MATCH

ADJACENT FINISH AND TEXTURE. PREPARE SURFACES TO RECEIVE

PAINT AS INDICATED. SEE SHEET AE215 FOR ADDITIONAL INFORMATION

- TYPICAL

020 EXISTING GUTTER AND DOWNSPOUTS. REMOVE AND REINSTALL AS

REQUIRED TO COMPLETE NEW WORK

116 EXISTING HOSE BIB. SEE PLUMBING DRAWINGS

301 EXISTING VINES. REMOVE IN THEIR ENTIRETY, INCLUDING IN BRICK

JOINTS AND AIR SPACE BEHIND BRICK - TYPICAL

302 EXISTING BRICK CRACK. CLEAN, PATCH, REPAIR AS REQUIRED. SEE

SHEET AE215 AND SPECIFICATIONS FOR ADDITIONAL INFORMATION -

TYPICAL

303 EXISTING LIMESTONE. CLEAN, PATCH, REPAIR AS REQUIRED. SEE

SHEET AE215 AND SPECIFICATIONS FOR ADDITIONAL INFORMATION -

TYPICAL

304 AREA OF REMOVAL OF EXISTING BRICK REPAIR AND REPLACE WITH

NEW BRICK TO MATCH ORIGINAL EXISTING BRICK - TYPICAL

305 REMOVE VENT IN ITS ENTIRY. INFILL OPENING TO MATCH ADJACENT

MATERIALS, SURFACES AND FINISH, OR NEW LOUVER. SEE MECHANICAL

DRAWINGS FOR ADDITIONAL INFORMATION - TYPICAL

306 PATCH, REPAIR STUCCO TEXTURE, FINISH, AND APPLICATION METHOD

TO MATCH ORIGINAL EXISTING STUCCO. SEE SHEET AE215 FOR

ADDITIONAL INFORMATION - TYPICAL

307 REMOVE LOUVERS IN THEIR ENTIRY. INFILL OPENING TO MATCH

ADJACENT MATERIALS, SURFACES AND FINISH, OR NEW LOUVER. SEE

MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION - TYPICAL

1" = 1'-0"L1

EXT. FACE BRICK - TYP

1" = 1'-0"L5

EXT. FACE BRICK - TYP

1" = 1'-0"D1

EXT. STUCCO - TYP

1" = 1'-0"L9

EXT. FACE BRICK - TYP

1" = 1'-0"L13

EXT. FACE BRICK - TYP

1" = 1'-0"H1

EXT. FACE BRICK - TYP

NTSD13

LIMESTONE AND BRICK

CRACK REPAIR DETAIL -

TYPICAL

NTSD9

LIMESTONE SPALL REPAIR

DETAIL - TYPICAL

NTSD5

LIMESTONE SPALL REPAIR

DETAIL - TYPICAL

NTSH9

MORTAR JOINT REPAIR DETAILS -

TYPICAL

1" = 1'-0"H5

EXT. FACE BRICK - TYP

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

/1

/2

DVANLOON

Image

DVANLOON

Image

DVANLOON

Text Box 07/22/21

UNIT-D

B114

BATHROOM - D

/2

AE410 A14

S

IM

K14

S

IM

E14 SIM

A17 SIM

7' - 6 7/8"

2' - 7" 5' - 0"

03 0101

04 09

11A

09A

2' - 0"

/4

1' - 3"

2' - 9"

/8 " 3' - 0"

CORR

C139AE414

L1 SIM

L6

S

IM

AE415

G7

L7

11' - 1"

1' - 8 1/2"

11A

12 03B

02A

C134-A

11A

1' - 6"

ABA UNIT-D

C134

ABA BATH - D

2' - 6"

ALIGN

5' - 0"

UNIT-F

C234

BATHROOM - F

AE415 L12

03C

SEE FLOOR PLANS

FOR PARTITION TYPE

AE414

F13 SIM

A12

G12

A

R

T B

C 084

PT-6

PTB-2

PWT-1

PTB-1

B

C

F

K D

D

PT-6

PTB-2

PTB-1

PWT-1

L B

A

K

E

PT-6

PTB-2

PWT-1

PTB-1

A. SEE SHEET AF601 FOR UNIT BATHROOM TYPICAL FLOOR

FINISH PLAN

B. SEE SHEETS AF601, AF602 AND AF603 FOR FINISH KEY AND

FINISH SCHEDULE

C. SEE SHEET AF601 FOR FLOOR TRANSITION DETAILS

D. SEE SHEET AE413 FOR TOILET ACCESSORY SCHEDULE

E. REFER TO SHEET A-002 FOR ABA MOUNTING HEIGHTS

F. SEE IF111 FOR EQUIPMENT LEGEND

G. SEE IF-SHEETS FOR FURNITURE LAYOUTS

H. SEE SHEET AE504 FOR MILLWORK DETAILS

I. ALL LOCKER ROOM SHOWERS TO HAVE ROLL-IN TYPE

FLOOR TRANSITION. REFER TO SHEET AE503 FOR FLOOR

TRANSITION DETAILS.

J. SEE AE508 FOR CEILING DETAILS

GENERAL NOTES:

LEGEND:

1/2 HOUR SMOKE RATED WALL

1 HOUR FIRE RATED WALL

PARTITION TYPE SYMBOL, REFER

TO SHEETS AE701, AE702, AND

AE703

NEW INFILL WALL

NEW INTERIOR PARTITION

EXISTING WALL TO REMAIN

2 HOUR FIRE RATED WALL,

SEE LIFE SAFETY PLANS

A

B

PT-6

PTB-2

PTB-1

PWT-1

T

D

D

C

PT-6

PTB-2

PWT-1

PTB-1

E

US Army Corps of Engineers ®

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

E O

R G

IA

JO

N

E S

F R

A N

K

LI

N R

D , S

U

IT

E

R A

LE

IG

H , N

C

-3

(9

1-

(9

1-

F

A X

LI

C

E N

S E

F

-0

F O

R T

B E

N N

IN

G

G

A B

U

IL

D

IN

G

T

R A

IN

E

E B

A R

R A

C K

S U

P G

R A

D E

P R

O G

R

U P

P

H A

S E

F

Y P

N

FOR OFFICIAL USE ONLY

AE415

E N

L A

R G

E D

B A

T H

R O

O M

P L A

N S

I

N T

E R

IO

R

E L E

V A

T

IO

N S

T

Y P

IC

A

L U

N

IT

S

D

E

F

A N

D G

Z K

A S

K Y

D V

A N

L O

O N

K B

R O

D B

E R

K B

R O

D B

E R

J U

L Y

W H

N B

- 7 -1

-2

C

A T

E G

O R

Y C

O D

E

F

IL

E N

A M

E A

E .D

W G

R E

A D

Y T

O A

D V

E R

T

IS

E

R T

A

PLAN

NORTH

1/2" = 1'-0"A1

ENLARGED PLAN (BATHROOM - D)

1/2" = 1'-0"A7

ENLARGED PLAN (ABA BATH - D)

0 1' 2' 4'

1/2" = 1'-0"H1

ENLARGED PLAN, BATHROOM - F /

BATHROOM - E (OPP HAND)

1/2" = 1'-0"L12

ELEVATION (BATHROOM - F)

1/2" = 1'-0"G7

ELEVATION (ABA BATH - D)

1/2" = 1'-0"L7

ELEVATION (ABA BATH - D)

KEYNOTES

084 SURFACE MOUNTED LIGHT FIXTURE

103 SHOWER CURB. SEE SHEET AE503 FOR DETAILS

114 12"X12" ACCESS PANEL, 12" AFF. SEE MECHANICAL

DRAWINGS

157 SHELF AND HANGER ROD. SEE SHELF DETAILS ON

SHEET AE503

1/2" = 1'-0"G12

ELEVATION (BATHROOM - F)

1/2" = 1'-0"A12

ELEVATION (BATHROOM - F)

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

/1

/2

DVANLOON

Image

DVANLOON

Image

DVANLOON

TYPE F TYPE P TYPE G

GL5 WITH

APPLIED GRID

(SAME FIRE

RATING AS DOOR)

TYPE FG

GL5

(SAME FIRE

RATING AS DOOR)

TYPE N

GL5 4"X24" VISION

PANEL (SAME FIRE

RATING AS DOOR)

4" 6"

4" 4"

KICK PLATE

PER

SCHEDULE

KICK PLATE

PER

SCHEDULE

HM DOOR.

FINISH AS

SCHEDULED

TYPE 1 TYPE 2 TYPE 3A

TYPE 4

P E

R S

C H

E D

U L E

2"

SCHEDULE

PER

2"

P E

R S

C H

E D

U L E

P E

R S

C H

E D

U L E

2"

SCHEDULE

PER

2"

TYPE 5

5' - 7"

'-8

(L

E V

E L

P E

R S

C H

E D

U L E

F V

V

A R

IE

S

PER SCHEDULE

3' - 4"

'-8

(L

E V

E L

P E

R S

C H

E D

U L E

F V

V

A R

IE

S

PER SCHEDULE

3' - 4"

P E

R S

C H

E D

U L E

2" PER SCHEDULE 2"

1' - 11"

TYPE 6

'-8

(L

E V

E L

P E

R S

C H

E D

U L E

F V

V

A R

IE

S

2" PER SCHEDULE 2"

TYPE 3

P E

R S

C H

E D

U L E

2" PER SCHEDULE 2"

TYPE 0

P E

R S

C H

E D

U L E

PER SCHEDULE

GL3 WITH

APPLIED GRID,

TYP.

GL2

GL3 - 1ST FLOOR.

GL2 - 2ND & 3RD

FLOORS, TYP.

GL3 - 1ST FLOOR.

GL2 - 2ND & 3RD

FLOORS, TYP.

ALUMINUM STOREFRONT

SYSTEM WITH HOLLOW

METAL DOOR, TYP. FOR

EXTERIOR DOOR SYSTEMS

SEE AE607 FOR DETAILS

IP-1

AL ALUMINUM

WD WOOD

HM HOLLOW METAL

STC SOUND TRANSMISSION COEFFICIENT

AT/FP ANTI-TERRORISM/ FORCE PROTECTION

F FLUSH

N NARROW LITE

P PANELED

FG FULL GLASS

FL FULL LOUVER

PRE. FIN. PREFINISHED (FACTORY FINISH)

PNT PAINTED

GL1 INSULATED/ LAMINATED 0.030 PVB/TINTED/ LOW-E

GL2 INSULATED/ LAMINATED 0.030 PVB/CLEAR/ LOW-E

GL3 INSULATED/ LAMINATED 0.030 PVB/SPANDREL/ LOW-E

GL4 RATED 1/2" LAMINATED/ CLEAR/ 0.030 PVB

GL5 FIRE RATED GLASS (SAME FIRE RATING AS DOOR)

IP-1 INSULATED PANEL (SEE AE215 FOR FINISH SCHEDULE)

IP-2 INSULATED PANEL (SEE AE215 FOR FINISH SCHEDULE)

DOOR SCHEDULE LEGEND

REMARKS:

1. 1 PR. EQUAL SIZE DOORS WITHIN SPECIFIED WIDTH IN SCHEDULE.

2. VISION PANEL MARKED D-H-90 OR D-H-W-90.

3. UNDERCUT DOOR BY 1-1/2" FOR AIR FLOW

4. FIRE RATED VISION PANEL ON DOOR, SAME FIRE RATING AS DOOR

5. DOOR VIEWER CENTERED ON DOOR AT 5'-6" AFF.

6. VISION PANEL MARKED D-H-45 OR D-H-W-45.

7. BIFOLD DOORS - 4 EQUAL SIZE DOORS WITHIN SPECIFIED WIDTH IN SCHEDULE.

8. DOOR CLOSER WITH HOLD OPEN ARM.

9. DRYWALL OPENING.

10. GLASS LITE/ VISION PANEL WITH BLAST RESISTANT GLASS.

11. FIELD VERIFY EXISTING DOOR SIZE.

12. SEE STRUCTURAL FOR DOOR HEAD DETAILS.

US Army Corps of Engineers ®

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

E O

R G

IA

JO

N

E S

F R

A N

K

LI

N R

D , S

U

IT

E

R A

LE

IG

H , N

C

-3

(9

1-

(9

1-

F

A X

LI

C

E N

S E

F

-0

F O

R T

B E

N N

IN

G

G

A B

U

IL

D

IN

G

T

R A

IN

E

E B

A R

R A

C K

S U

P G

R A

D E

P R

O G

R

U P

P

H A

S E

F

Y P

N

FOR OFFICIAL USE ONLY

AE601

D O

O R

S C

H E

D U

L E

D

O O

R A

N D

F R

A M

E T

Y P

E S

Z K

A S

K Y

D V

A N

L O

O N

K B

R O

D B

E R

K B

R O

D B

E R

J U

L Y

W H

N B

- 7 -1

-2

C

A T

E G

O R

Y C

O D

E

F

IL

E N

A M

E A

E .D

W G

R E

A D

Y T

O A

D V

E R

T

IS

E

R T

A

DOOR SCHEDULE - LEVEL 01 & LEVLEL 02

DOOR

ID

ROOM NAME

ROOM

NUMBER

DOOR

HARDWARE

HEADING NO.

FRAME

REMARKS

SIZE TYPE

MAT'

L

CLASS PERFORMANCE FINISH COATING RATING GLAZING ACCOUST.

MAT'L FINISH COATING TYPE

DETAIL

HEAD JAMB THRESHOLD

TOF

B100-3 EXISTING STORAGE B100-3 2' - 5" x 6' - 3" x 0' - 2" F HM PNT 12 HM PNT 1 DH6/AE608 (SIM) DJ6/AE608 (SIM) - 11

C100-3 EXISTING STORAGE C100-3 2' - 5" x 6' - 3" x 0' - 2" F HM PNT 12 HM PNT 1 DH6/AE608 (SIM) DJ6/AE608 (SIM) - 11

C100b-3 EXISTING STORAGE C100b-3 2' - 5" x 6' - 3" x 0' - 2" F HM PNT 12 HM PNT 1 DH6/AE608 (SIM) DJ6/AE608 (SIM) - 11

1ST FLOOR

B MECH. ENCLOSURE B 9' - 2" x 8' - 0" x 0' - 2" - - - - - - N/A - - -

B100 EXISTING STORAGE B100 5' - 0" x 7' - 0" x 0' - 2" - - - 11 - - N/A - - -

B100-2 EXISTING STORAGE B100 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 12 HM PNT 2 DH6/AE608 (SIM) DJ6/AE608 (SIM) - 11

B109 MECH RM B109 6' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. STC 50 13 HM PNT 3A DH3/AE607 DJ3/AE607 - 1

B111 ELEC RM B111 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. - 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

B127-E CORR B127 3' - 4" x 7' - 6" x 0' - 2" P HM PNT 1 AL PRE. FIN. 4 DH1/AE607; DH1a/AE608 DJ1/AE607 T3/AE607 10

B129 JANITOR B129 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 9 HM PNT 2 DH3/AE607 DJ3/AE607 -

B130-1 EGRESS CORRIDOR B130 3' - 0" x 7' - 0" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH3/AE607 DJ3/AE607 - 6, 8

B130-2 EGRESS CORRIDOR B130 3' - 0" x 7' - 0" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH3/AE607 DJ3/AE607 - 6, 8

B130-E EGRESS CORRIDOR B130 3' - 4" x 7' - 6" x 0' - 1 3/4" P HM PNT 1 AL PRE. FIN. 5 DH1/AE607; DH1a/AE608 DJ5/AE607 (SIM) T4/AE607 10

B131 LAUNDRY B131 3' - 0" x 7' - 0" x 0' - 2" N HM PNT 45 MIN. GL5 9 HM PNT 2 DH3/AE607 DJ3/AE607 - 4

B132 RESTROOM B132 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 20 MIN. 10 HM PNT 1 DH3/AE607 DJ3/AE607 -

B133 STOR. B133 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

B134 TELECOM B134 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. - 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

B135 EGRESS CORRIDOR B130 3' - 0" x 7' - 0" x 0' - 2" N HM PNT 45 MIN. GL5 7 HM PNT 2 DH3/AE607 DJ3/AE607 - 4

B135-E CORR B135 3' - 0" x 7' - 6" x 0' - 1 3/4" P HM PNT 1 AL PRE. FIN. 4 DH1/AE607; DH1b/AE608 DJ5/AE607 T3/AE607 10

B136 STAIR 1 B136 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10

B136-A STAIR 1 B136 3' - 0" x 4' - 10" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 1 - - - 11

B150 STOR. B150 2' - 0" x 5' - 1" x 0' - 2" F HM PNT 12 HM PNT 1 DH6/AE608 (SIM) DJ6/AE608 (SIM) T1/AE607 11

B151 STOR. B151 2' - 0" x 5' - 1" x 0' - 2" F HM PNT 12 HM PNT 1 DH6/AE608 (SIM) DJ6/AE608 (SIM) T1/AE607 12

C MECH. ENCLOSURE C 9' - 2" x 8' - 0" x 0' - 2" - - - - - - N/A - - -

C100 EXISTING STORAGE C100 5' - 0" x 7' - 0" x 0' - 2" - - - 11 - - N/A - - -

C100-2 EXISTING STORAGE C100 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 12 HM PNT 2 DH6/AE608 (SIM) DJ6/AE608 (SIM) - 11

C100b EXISTING STORAGE C100b 5' - 0" x 7' - 0" x 0' - 2" - - - 11 - - N/A - - -

C100b-2 EXISTING STORAGE C100b 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 12 HM PNT 2 DH6/AE608 (SIM) DJ6/AE608 (SIM) - 11

C113 MECH RM C113 6' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. STC 50 13 HM PNT 3A DH3/AE607 DJ3/AE607 - 1

C130 LAUNDRY C130 3' - 0" x 7' - 0" x 0' - 2" N HM PNT 45 MIN. GL5 9 HM PNT 2 DH3/AE607 DJ3/AE607 - 4

C132 LOCKERS (MEN) C132 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 10 HM PNT 1 DH4/AE607 DJ4/AE607 - 3

C133 LOCKERS (WOMEN) C133 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 10 HM PNT 1 DH4/AE607 DJ4/AE607 - 3

C136 OFFICERS LOUNGE C136 3' - 0" x 7' - 0" x 0' - 2" FG HM PNT 20 MIN. 3 HM PNT 2 DH3/AE607 DJ3/AE607 - 4

C137-O VESTIBULE C137 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - 0 - - - 9

C138 LOBBY C138 3' - 0" x 7' - 0" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH3/AE607 DJ3/AE607 - 6, 8

C138-E LOBBY C138 6' - 0" x 7' - 6" x 0' - 1 3/4" P HM PNT 2 AL PRE. FIN. 6 DH1/AE607; DH1a/AE608 DJ1/AE607 T3/AE607 1, 10

C139-O CORR C139 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - - - - 0 - - - 9

C140-E CORR C140 6' - 0" x 7' - 6" x 0' - 1 3/4" P HM PNT 2 AL PRE. FIN. 6 DH1/AE607; DH1b/AE608 DJ5/AE607 T3/AE607 1, 10

C141-E LOBBY C141 6' - 0" x 7' - 6" x 0' - 1 3/4" P HM PNT 2 AL PRE. FIN. 6 DH1/AE607; DH1b/AE608 DJ5/AE607 T3/AE607 1, 10

C142 RESTROOM C142 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 20 MIN. 10 HM PNT 1 DH3/AE607 DJ3/AE607 -

C143 ELEC RM C143 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

C144 STOR. C144 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

C145 TELECOMM C145 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

C146 STAIR 3 C146 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10

C146-A STAIR 3 C146 3' - 0" x 4' - 10" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 1 - - -

C146-E STAIR 3 C146 3' - 8" x 7' - 0" x 0' - 2" P HM PNT - 1 HM PNT 2 DH6/AE608 DJ6/AE608 T3/AE607

C147-O CORR C140 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - - - - - 0 - - - 9

C148-E CORR C148 3' - 4" x 7' - 6" x 0' - 1 3/4" P HM PNT 1 AL PRE. FIN. 4 DH1/AE607; DH1a/AE608 DJ1/AE607 T3/AE607 10

C149 CORR C149 3' - 0" x 7' - 0" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH3/AE607 DJ3/AE607 - 6, 8

C150-E LOBBY C150 6' - 0" x 7' - 6" x 0' - 1 3/4" P HM PNT 2 AL PNT 6 DH1/AE607; DH1b/AE608 DJ5/AE607 T3/AE607 1, 10

C151-E CORR C151 6' - 0" x 7' - 6" x 0' - 1 3/4" P HM PNT 2 AL PRE. FIN. 6 DH1/AE607; DH1b/AE608 DJ5/AE607 T3/AE607 1, 10

C152 RESTROOM C152 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 20 MIN. 10 HM PNT 1 DH3/AE607 DJ3/AE607 -

C153 ELEC RM C153 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

C154 STOR. C154 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

C155 TELECOM C155 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

C157 LAUNDRY C157 3' - 0" x 7' - 0" x 0' - 2" N HM PNT 45 MIN. GL5 9 HM PNT 2 DH3/AE607 DJ3/AE607 - 4

C158 ELEC RM C158 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

C158-0 ELEC RM C158 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - - - 0 - - - 9

C159 STAIR 2 C159 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10

C159-B STAIR 2 C159 3' - 0" x 4' - 10" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 1 - - -

C160 CORR C160 3' - 0" x 7' - 0" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH3/AE607 DJ3/AE607 - 6, 8

C161 CORR C161 3' - 0" x 7' - 0" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH3/AE607 DJ3/AE607 - 6, 8

C161-E CORR C161 3' - 4" x 7' - 6" x 0' - 1 3/4" P HM PNT 1 AL PRE. FIN. 4 DH1/AE607; DH1a/AE608 DJ1/AE607 T3/AE607 10

C170 STOR. C170 2' - 0" x 5' - 1" x 0' - 2" F HM PNT 12 HM PNT 1 DH6/AE608 (SIM) DJ6/AE608 (SIM) - 11

C171 STOR. C171 2' - 0" x 5' - 1" x 0' - 2" F HM PNT 12 HM PNT 1 DH6/AE608 (SIM) DJ6/AE608 (SIM) - 11

C172 STOR. C172 2' - 0" x 5' - 1" x 0' - 2" F HM PNT 12 HM PNT 1 DH6/AE608 (SIM) DJ6/AE608 (SIM) - 11

C173 STOR. C173 2' - 0" x 5' - 1" x 0' - 2" F HM PNT 12 HM PNT 1 DH6/AE608 (SIM) DJ6/AE608 (SIM) - 11

2ND FLOOR

B211 ELEC. RM. B211 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

B227-E CORR B227 3' - 4" x 7' - 6" x 0' - 1 3/4" P HM PNT 1 AL PRE. FIN. 4 DH1/AE607; DH1a/AE608 DJ1/AE607 T1/AE607 10

B229 JANITOR B229 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 9 HM PNT 2 DH3/AE607 DJ3/AE607 -

B230-E VESTIBULE B230 3' - 4" x 7' - 6" x 0' - 1 3/4" p HM PNT 1 AL PRE. FIN. 5 DH1/AE607; DH1a/AE608 DJ5/AE607 T1/AE607 10

B231 LAUNDRY B231 3' - 0" x 7' - 0" x 0' - 2" N HM PNT 45 MIN. GL5 9 HM PNT 2 DH3/AE607 DJ3/AE607 - 4

B232 RESTROOM B232 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 20 MIN. 10 HM PNT 1 DH3/AE607 DJ3/AE607 -

B233 STOR. B233 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

B234 TELECOM B234 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

B236 STAIR 1 B236 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10

C213 LOUNGE C213 6' - 0" x 7' - 0" x 0' - 2" FG HM PNT 20 MIN. GL5 13 HM PNT 3A DH3/AE607 DJ3/AE607 - 1, 4

C230 LAUNDRY C230 3' - 0" x 7' - 0" x 0' - 2" N HM PNT 45 MIN. GL5 9 HM PNT 2 DH3/AE607 DJ3/AE607 - 4

C231 LOUNGE C231 6' - 0" x 7' - 0" x 0' - 2" FG HM PNT 20 MIN. GL5 13 HM PNT 3A DH3/AE607 DJ3/AE607 - 1, 4

C238 CORR C238 3' - 0" x 7' - 0" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH3/AE607 DJ3/AE607 - 6, 8

C238-O CORR C238 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - - - 0 - - - 9

C240-E CORR C240 6' - 0" x 7' - 6" x 0' - 1 3/4" P HM PNT 2 AL PRE. FIN. 6 DH1/AE607; DH1b/AE608 DJ5/AE607 T1/AE607 1, 10

C241 JANITOR C241 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 9 HM PNT 2 DH3/AE607 DJ3/AE607 -

C242 RESTROOM C242 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 10 HM PNT 2 DH3/AE607 DJ3/AE607 -

C243 ELEC RM C243 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

C244 STOR. C244 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

C245 TELECOMM C245 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

C246 STAIR 3 C246 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10

C247-O CORR C247 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - - - 0 - - - 9

C248-E CORR C248 3' - 4" x 7' - 6" x 0' - 1 3/4" P HM PNT 1 AL PRE. FIN. 4 DH1/AE607; DH1a/AE608 DJ1/AE607 T1/AE607 10

C249-O CORR C249 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - - - - 0 - - - 9

C250-E LOBBY C250 6' - 0" x 7' - 6" x 0' - 1 3/4" P HM PNT 2 AL PRE. FIN. 6 DH1/AE607; DH1b/AE608 DJ5/AE607 T1/AE607 1, 10

C252 RESTROOM C252 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 20 MIN. 10 HM PNT 1 DH3/AE607 DJ3/AE607 -

C253 ELEC. RM. C253 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

C254 JC C254 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 9 HM PNT 2 DH3/AE607 DJ3/AE607 -

C255 TELECOM C255 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

C257 LAUNDRY C257 3' - 0" x 7' - 0" x 0' - 2" N HM PNT 45 MIN. GL5 9 HM PNT 2 DH3/AE607 DJ3/AE607 - 4

C258 STOR. C258 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

C259 STAIR 2 C259 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10

C260-O CORR C260 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - - - - 0 - - - 9

C261 CORR C261 3' - 0" x 7' - 0" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH3/AE607 DJ3/AE607 - 6, 8

C261-E CORR C261 3' - 4" x 7' - 6" x 0' - 1 3/4" P HM PNT 1 AL PRE. FIN. 4 DH1/AE607; DH1a/AE608 DJ1/AE607 T1/AE607 10

1/4" = 1'-0"

DOOR TYPES

1/4" = 1'-0"

FRAME TYPES

0 2' 4' 8' 12'

GENERAL NOTES - DOOR SCHEDULE:

A. FIELD VERIFY EXISTING CONDITIONS AT EXTERIOR DOOR

THRESHOLDS. USE APPROPRIATE THRESHOLD TYPES TO

SUIT EXISTING CONDITIONS

B. GENERAL CONTRACTOR IS RESPONSIBLE FOR SELECTING

CORRECT THRESHOLD TYPES TO FACILITATE SITE

CONDITIONS

C. REFER TO SHEET AF601 FOR FLOOR TRANSITION DETAILS

D. WHERE ALUMINUM STOREFRONT SYSTEMS ARE USED WITH

HM DOORS, COAT ALUMINUM FRAMES WITH CORROSION

PREVENTATIVE METAL COATINGS AT DOORWAYS TO

PREVENT DISSIMILAR METAL CORROSION

E. ALSO SEE SHEET AE215 FOR EXTERIOR FINISHES

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

/1

/2

DVANLOON

Image

DVANLOON

Image

DVANLOON

TYPE 100

3' - 4"

TYPE 102 TYPE 105 TYPE 106

5' - 7" 7' - 2" 3' - 5 1/2"

TYPE 200/ 300

3' - 4"

TYPE 202/ 302 TYPE 205/ 305 TYPE 206/ 306

5' - 7" 7' - 2" 3' - 5 1/2"

TYPE 400 TYPE 404

" 3

3' - 4"

13' - 8"

IP-1, TYP.IP-1

GL3, TYP.

GL1, TYP.

TYPE W1

5' - 0"

2" 2"

FIRE RATED

GLAZING

NOTE: SEE F12/AE409 FOR

WALL ELEVATION

GL3, TYP.

GL1, TYP.

TYPE 401

/2

F

V

3' - 4" FV.

/2

TYPE 403

/2

F V

5' - 7" FV.

IP-2

IP-2

US Army Corps of Engineers ®

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

E O

R G

IA

JO

N

E S

F R

A N

K

LI

N R

D , S

U

IT

E

R A

LE

IG

H , N

C

-3

(9

1-

(9

1-

F

A X

LI

C

E N

S E

F

-0

F O

R T

B E

N N

IN

G

G

A B

U

IL

D

IN

G

T

R A

IN

E

E B

A R

R A

C K

S U

P G

R A

D E

P R

O G

R

U P

P

H A

S E

F

Y P

N

FOR OFFICIAL USE ONLY

AE602

D O

O R

W

IN

D

O W

A N

D L

O U

V E

R S

C H

E D

U L E

S

Z K

A S

K Y

D V

A N

L O

O N

K B

R O

D B

E R

K B

R O

D B

E R

J U

L Y

W H

N B

- 7 -1

-2

C

A T

E G

O R

Y C

O D

E

F

IL

E N

A M

E A

E .D

W G

R E

A D

Y T

O A

D V

E R

T

IS

E

R T

A

DOOR SCHEDULE -LEVEL 03 & LEVEL 04

DOOR

ID

ROOM NAME

ROOM

NUMBE

R

DOOR HARDWARE

HEADING

NO.

FRAME

REMARKS

SIZE TYPE MAT'L CLASS PERFORMANCE FINISH COATING RATING GLAZING ACCOUST.

MAT'L FINISH COATING TYPE

DETAIL

HEAD JAMB THRESHOLD

3RD FLOOR

B311 ELEC. RM B311 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

B327-E CORR B327 3' - 4" x 7' - 6" x 0' - 1 3/4" P HM PNT 1 AL PRE. FIN. 4 DH1/AE607; DH1a/AE607 DJ1/AE607 T1/AE607 10

B328 JANITOR B328 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 9 HM PNT 2 DH3/AE607 DJ3/AE607 -

B329

ELEVATOR

CONTROLLER

B329 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2

DH3/AE607 DJ4/AE607

B330-E VESTIBULE B330 3' - 4" x 7' - 6" x 0' - 1 3/4" P HM PNT 1 AL PRE. FIN. 5 DH1/AE607; DH1b/AE607 DJ5/AE607 T1/AE607 10

B331 LAUNDRY B331 3' - 0" x 7' - 0" x 0' - 2" N HM PNT 45 MIN. GL5 9 HM PNT 2 DH3/AE607 DJ3/AE607 - 4

B332 RESTROOM B332 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 20 MIN. 10 HM PNT 1 DH3/AE607 DJ3/AE607 -

B333 STOR. B333 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

B334 TELECOM B334 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

B336 STAIR 1 B336 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10

C313 LOUNGE C313 6' - 0" x 7' - 0" x 0' - 2" FG HM PNT 20 MIN. GL5 13 HM PNT 3A DH3/AE607 DJ3/AE607 - 1, 4

C330 LAUNDRY C330 3' - 0" x 7' - 0" x 0' - 2" N HM PNT 45 MIN. GL5 9 HM PNT 2 DH3/AE607 DJ3/AE607 - 4

C331 LOUNGE C331 6' - 0" x 7' - 0" x 0' - 2" FG HM PNT 20 MIN. GL5 13 HM PNT 3A DH3/AE607 DJ3/AE607 - 1, 4

C338 CORR C338 3' - 0" x 7' - 0" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH3/AE607 DJ3/AE607 - 6, 8

C338-O CORR C338 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - - - - 0 - - - 9

C340-E CORR C340 6' - 0" x 7' - 6" x 0' - 1 3/4" P HM PNT 2 AL PRE. FIN. 6 DH1/AE607; DH1b/AE607 DJ5/AE607 T1/AE607 1, 10

C341 JANITOR C341 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 9 HM PNT 2 DH3/AE607 DJ3/AE607 -

C342 RESTROOM C342 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 20 MIN. 10 HM PNT 1 DH3/AE607 DJ3/AE607 -

C343 ELEC RM C343 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

C344 STOR. C344 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

C345 TELECOMM C345 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

C346 STAIR 3 C346 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10

C347-O CORR C347 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - - - - 0 - - - 9

C348-E CORR C348 3' - 4" x 7' - 6" x 0' - 1 3/4" P HM PNT 1 AL PRE. FIN. 4 DH1/AE607; DH1a/AE607 DJ1/AE607 T1/AE607 10

C349-O CORR C349 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - - - - 0 - - - 9

C350-E LOBBY C350 6' - 0" x 7' - 6" x 0' - 1 3/4" P HM PNT 2 AL PRE. FIN. 6 DH1/AE607; DH1b/AE607 DJ5/AE607 T1/AE607 1, 10

C352 RESTROOM C352 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 20 MIN. 10 HM PNT 1 DH3/AE607 DJ3/AE607 -

C353 ELEC RM C353 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

C354 JC C354 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 9 HM PNT 2 DH3/AE607 DJ3/AE607 -

C355 TELECOMM C355 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

C357 LAUNDRY C357 3' - 0" x 7' - 0" x 0' - 2" N HM PNT 45 MIN. GL5 9 HM PNT 2 DH3/AE607 DJ3/AE607 - 4

C358 STOR. C358 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 20 MIN. 8 HM PNT 2 DH3/AE607 DJ3/AE607 -

C359 STAIR 2 C359 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10

C360-O CORR C360 4' - 0" x 8' - 0" x 0' - 0" 0 - - - - - - - - 0 - - - 9

C361 CORR C361 3' - 0" x 7' - 0" x 0' - 2" G HM PNT 45 MIN. GL5 7 HM PNT 2 DH3/AE607 DJ3/AE607 - 6, 8

C361-E CORR C361 3' - 4" x 7' - 6" x 0' - 1 3/4" P HM PNT 1 AL PRE. FIN. 4 DH1/AE607; DH1a/AE607 DJ1/AE607 T1/AE607 10

4TH FLOOR/ ATTIC

B401 ATTIC B401 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH2/AE607 DJ2/AE607 -

B410 MECHANICAL RM B410 6' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. STC 50 13 HM PNT 3A DH2/AE607 (SIM) DJ2/AE607 (SIM) - 1, 12

B410-1 ATTIC B402 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH2/AE607 DJ2/AE607 -

B430 STORAGE RM B430 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 8 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10

B430-C CLOSET 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 6 HM PNT 1 DH4/AE607 DJ4/AE607 -

C401 ATTIC C401 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH2/AE607 DJ2/AE607 -

C401-1 ATTIC C401 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 8 HM PNT 2 DH2/AE607 DJ2/AE607 -

C402 ATTIC C402 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH2/AE607 DJ2/AE607

C403 ATTIC C403 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH2/AE607 DJ2/AE607 -

C440 MECHANICAL RM C440 6' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. STC 50 13 HM PNT 3A DH2/AE607 (SIM) DJ2/AE607 (SIM) - 1, 12

C445 STORAGE RM C445 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 8 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10

C445-C CLOS. 2' - 6" x 7' - 0" x 0' - 2" F WD STAIN 6 HM PNT 1 DH4/AE607 DJ4/AE607 -

C450 MECHANICAL RM C450 6' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. STC 50 13 HM PNT 3A DH2/AE607 (SIM) DJ2/AE607 (SIM) - 1, 12

C450-1 ATTIC C402 3' - 0" x 7' - 0" x 0' - 2" F HM PNT 45 MIN. 8 HM PNT 2 DH2/AE607 DJ2/AE607 -

C452 STORAGE RM C452 3' - 4" x 7' - 6" x 0' - 2" G HM PNT 45 MIN. GL5 8 HM PNT 2 DH2/AE607 DJ2/AE607 - 2, 10

C452-C CLOS. 2' - 6" x 7' - 0" x 0' - 2" F WD STAIN 6 HM PNT 1 DH4/AE607 DJ4/AE607 -

WINDOW SCHEDULE

WINDOW

TYPE

GLAZING MAT'L FINISH ACOUSTCS

DETAIL

REMARKS COUNT

HEAD JAMB SILL

1ST FLOOR

100 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH1/AE605 & WH4/AE606 WJ1/AE605 & WJ4/AE606 WS1/AE605 & WS4/AE606 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 41

102 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH4/AE606 WJ4/AE606 WS4/AE606 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 8

105 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH2/AE605 WJ2/AE605 WS2/AE605 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 19

106 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH2/AE605 & WH4/AE606 WJ2/AE605 & WJ4/AE606 WS2/AE605 & WS4/AE606 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 33

W1 GL5 HM PNT INTERIOR GLAZING, OFFICER'S LOUNGE 1

2ND FLOOR

200 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH1/AE605 & WH4/AE606 WJ1/AE605 & WJ4/AE606 WS1/AE605 & WS4/AE606 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 44

202 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH4/AE606 WJ4/AE606 WS4/AE606 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 8

205 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH2/AE605 WJ2/AE605 WS2/AE605 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 19

206 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH2/AE605 & WH4/AE606 WJ2/AE605 & WJ4/AE606 WS2/AE605 & WS4/AE606 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 33

3RD FLOOR

300 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH1/AE605 & WH4/AE606 WJ1/AE605 & WJ4/AE606 WS1/AE605 & WS4/AE606 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 44

302 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH4/AE606 WJ4/AE606 WS4/AE606 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 8

305 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH2/AE605 WJ2/AE605 WS2/AE605 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 19

306 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH2/AE605 & WH4/AE606 WJ2/AE605 & WJ4/AE606 WS2/AE605 & WS4/AE606 ASSEMBLY TO MEET AT/FP REQUIREMENTS AND WIND LOADS 33

4TH FLOOR/ ATTIC

400 INSULATED PANEL AL PRE. FIN. WH3/AE605 WJ3/AE605 WS3/AE605 26

404 INSULATED DOUBLE PANE LOW E AL PRE. FIN. WH3/AE605 WJ3/AE605 WS3/AE605 32

0 2' 4' 8' 12'

1/4" = 1'-0"

WINDOW TYPES

DOOR SCHEDULE - TYPICAL UNITS

DOOR

ID

ROOM NAME

DOOR HARDWARE

HEADING

NO.

FRAME

REMARKS COUNT

SIZE TYPE MAT'L CLASS PERFORMANCE FINISH COATING RATING GLAZING ACCOUST. MAT'L. FINISH COATING TYPE

DETAIL

HEAD JAMB THRESHOLD

xxxx-A UNIT 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 20 MIN. STC 50 3 HM PNT 1 DH3/AE607 DJ3/AE607 - 5, 12 161 xxxx-B BATHROOM 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 4 HM PNT 1 DH4/AE607 DJ4/AE607 T2/AE607 161 xxxx-C CLOSET 7' - 0" x 7' - 0" x 0' - 2" F WD STAIN 5 - PNT N/A DH7/AE608 DJ7/AE608 - 7 96 xxxx-D CLOSET 7' - 0" x F WD STAIN 5 - PNT N/A DH7/AE608 DJ7/AE608 - 7 64 xxxx-F CLOSET 3' - 0" x 7' - 0" x 0' - 2" F WD STAIN 6 HM PNT 1 DH4/AE607 DJ4/AE607 - 1

1/4" = 1'-0"

LOUVER TYPES

LOUVER SCHEDULE

WINDOW

TYPE

GLAZING MAT'L FINISH ACOUSTCS

DETAIL

REMARKS COUNT

HEAD JAMB SILL

4TH FLOOR/ ATTIC

401 N/A AL PRE. FIN. LH1/AE606 LJ1/AE606 LS1/AE606 DRAINABLE METAL LOUVERS. FOR FINISH SEE AE215 BUILDING EXTERIOR FINISHES TABLE 2

403 N/A AL PRE. FIN. LH1/AE606 LJ1/AE606 LS1/AE606 DRAINABLE METAL LOUVERS. FOR FINISH SEE AE215 BUILDING EXTERIOR FINISHES TABLE 2

GENERAL NOTES - WINDOW SCHEDULE:

A. PROVIDE FULL SPANDREL GLAZING FOR WINDOWS IN

TELECOMM ROOMS ON BALCONY SIDE ONLY. SEE FLOOR

PLANS.

B. PROVIDE FULL SPANDREL GLAZING FOR WINDOW ADJACENT

TO SHOWER STALL IN LOCKER ROOM (WOMEN) C133.

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

/1

/2

DVANLOON

Image

DVANLOON

Image

DVANLOON

SEALANT W/ BACKER ROD

NEW FLASHING WITH

STAINLESS STEEL DRIP EDGE.

DO NOT BRIDGE GAPS WITH

SUBSTRATE

INSULATED GLAZING UNIT

NEW ALUMINUM WINDOW

SYSTEM

EXISTING STONE WINDOW SILL

EXISTING MASONRY WALL. FACE

BRICK ON FIRST FLOOR AND

TOWERS. STUCCO ON SECOND

AND THIRD FLOORS

SECURE WINDOW FRAME TO

STRUCTURAL STUDS

SOLID SURFACE

WINDOW SILL

5/8" TYPE X GYPSUM BOARD

SEALANT WITH

BACKER ROD

1" GAP/ MTL STUD OFFSET

FROM EXISTING WALL

2 1/2" MTL STUDS AT 24" O.C.

TYPE WS1

STREET SIDE

TREATED WOOD SHIM AND

BLOCKING AS REQUIRED

1"

2" CLOSED CELL SPRAY FOAM

URETHANE AIR BARRIER

INSULATION TO FILL 1" GAP

CONTINUOUS BEHIND MTL

STUDS AND 1" OF STUD SPACE

PROVIDE SEALANT

AT PERIMETER AS

REQUIREDFLUID APPLIED AIR

BARRIER

3/4"

2 1/2"

TYPE WS2

BALCONY SIDE

SOLID SURFACE

WINDOW SILL

NEW ALUMINUM

WINDOW SYSTEM

INSULATED GLAZING UNIT

SEALANT WITH

BACKER ROD

5/8" TYPE X GYPSUM

BOARD

2 1/2" MTL STUDS AT 24" O.C.

2" CLOSED CELL SPRAY FOAM

URETHANE AIR BARRIER

INSULATION TO FILL 1" GAP

CONTINUOUS BEHIND MTL

STUDS AND 1" OF STUD SPACE

EXISTING PAINTED

STUCCO, PATCH AND

REPAIR AS NEEDED

1"

3/4"

PROVIDE SEALANT AT

PERIMETER AS

REQUIRED

1" GAP/ MTL STUD OFFSET

FROM EXISTING WALL

FLUID APPLIED AIR

BARRIER

SECURE WINDOW FRAME

TO STRUCTURAL STUDS

TYPE WS3

STREET SIDE (ATTIC)

INTERIOR EXTERIOR

SEALANT WITH

BACKER ROD

NEW ALUMINUM

WINDOW SYSTEM

FLASHING WITH

STAINLESS STEEL DRIP

EDGE

SEALANT WITH

BACKER ROD

EXISTING

FLOOR SLAB

TREATED WOOD SHIM AND

BLOCKING AS REQUIRED

EXISTING STUCCO WALL

PATCH AND REPAIR AS

REQUIRED. PAINTED

NEW ALUMINUM

WINDOW SYSTEM

INSULATED

GLAZING UNIT

SECURE WINDOW FRAME

TO STRUCTURAL STUDS

2 1/2" MTL STUDS

AT 24" 0.C.

5/8" TYPE X

GYPSUM BOARD

SEALANT WITH

BACKER ROD

1" GAP/ MTL STUD OFFSET

FROM EXISTING WALL

FLASHING WITH STAINLESS

STEEL DRIP EDGE.

1' - 0" FV.1"

2" CLOSED CELL SPRAY FOAM

URETHANE AIR BARRIER

INSULATION TO FILL 1" GAP

CONTINUOUS BEHIND MTL STUDS

AND 1" OF STUD SPACE

ROLLER SHADE, SEE

TYPICAL DETAIL L9/AE605

PROVIDE SEALANT AT

PERIMETER AS REQUIRED

FLUID APPLIED AIR

BARRIER

CONTINUOUS BLOCKING

AS NEEDED TO MOUNT

ROLLER SHADE

TYPE WH2

BALCONY SIDE

EXISTING CONCRETE

BEAM, PAINTED

SEALANT W/

BACKER ROD

NEW ALUMINUM

WINDOW SYSTEM

INSULATED

GLAZING UNIT

FASTENERS THROUGH BACK

OF BRACKET FOR JAMB

MOUNT OPTION

PROVIDE SEALANT AT

PERIMETER AS REQUIRED

TREATED WOOD

SHIM AND BLOCKING

AS NEEDED

SECURE WINDOW

FRAME TO STUDS

1" GAP/ MTL STUD OFFSET

FROM EXISTING WALL

2" CLOSED CELL SPRAY FOAM

URETHANE AIR BARRIER

INSULATION TO FILL 1" GAP

CONTINUOUS BEHIND MTL

STUDS AND 1" OF STUD SPACE

1 5/8" MTL STUDS

AT 24" O.C.

FLUID APPLIED

AIR BARRIER

5/8" TYPE-X

GYPSUM BOARD

1' - 3" FV. 1"

ROLLER SHADE,

TYPICAL

TYPE WH3

BALCONY SIDE (ATTIC)

INTERIOR

EXTERIOR

EXISTING CONCRETE

BEAM, PAINTED

5/8" TYPE X GYPSUM BOARD

SEALANT AT PERIMETER

AS REQUIRED

NEW WINDOW

SYSTEM AS

SCHEDULED

SEALANT WITH

BACKER ROD,

BOTH SIDES

LTTR-11.4 2"

POLYSOCYANURATE RIGID

INSULATION ADHERED TO

STRUCTURE

1 5/8" MTL STUDS AT 24" O.C.

SHIM AND BLOCKING

AS REQUIRED

FV.

TYPE WJ1

STREET SIDE

TYPE WJ2

BALCONY SIDE

INTERIOR

EXTERIOR

EXISTING WALL,

PAINTED

5/8" TYPE X

GYPSUM BOARD

PROVIDE SEALANT AT

PERIMETER AS REQUIRED

NEW WINDOW SYSTEM AS

SCHEDULED

SEALANT W/ BACKER ROD

TYPE WJ3

ATTIC

LTTR-11.4 2"

POLYSOCYANURATE RIGID

INSULATION ADHERED TO

STRUCTURE

EXISTING MASONRY WALL. FACE

BRICK ON FIRST FLOOR AND

TOWERS, STUCCO ON SECOND AND

THIRD FLOORS

SEALANT WITH BACKER ROD

NEW ALUMINUM WINDOW

SYSTEM

INSULATED GLAZING UNIT

3/4" SOLID SURFACE

WINDOW SILL

2 1/2" MTL STUDS AT 24" O.C.

5/8" TYPE X GYPSUM BOARD

PROVIDE SEALANT AT

PERIMETER AS REQUIRED

EXISTING PAINTED

STUCCO, PATCH AND

REPAIR AS NEEDED

SEALANT WITH

BACKER ROD

NEW ALUMINUM

WINDOW SYSTEM

INSULATED

GLAZING UNIT

PROVIDE SEALANT AT

PERIMETER AS REQUIRED

3/4" SOLID SURFACE

WINDOW SILL

1 5/8" MTL STUD AT 24" O.C.

SECURE WINDOW FRAME TO

STRUCTURAL STUDS

FLUID APPLIED AIR BARRIER

F V

/4

1" GAP/ MTL STUD

OFFSET FROM

EXISTING WALL

2" CLOSED CELL SPRAY

FOAM URETHANE AIR

BARRIER INSULATION TO

FILL 1" GAP CONTINUOUS

BEHIND MTL STUDS AND

1" OF STUD SPACE

TREATED WOOD

SHIM AND BLOCKING

AS REQUIRED

1" GAP/ MTL STUD OFFSET

FROM EXISTING WALL

2" CLOSED CELL SPRAY FOAM URETHANE

AIR BARRIER INSULATION TO FILL 1" GAP

CONTINUOUS BEHIND MTL STUDS AND 1"

OF STUD SPACE

2 1/2" MTL STUDS AT 24" O.C.

SECURE WINDOW FRAME TO

STRUCTURAL STUDS

/4

FLUID APPLIED AIR BARRIER

5/8" TYPE X GYPSUM BOARD

US Army Corps of Engineers ®

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

E O

R G

IA

JO

N

E S

F R

A N

K

LI

N R

D , S

U

IT

E

R A

LE

IG

H , N

C

-3

(9

1-

(9

1-

F

A X

LI

C

E N

S E

F

-0

F O

R T

B E

N N

IN

G

G

A B

U

IL

D

IN

G

T

R A

IN

E

E B

A R

R A

C K

S U

P G

R A

D E

P R

O G

R

U P

P

H A

S E

F

Y P

N

FOR OFFICIAL USE ONLY

AE605

W

IN

D O

W D

E T

A

IL

S

Z K

A S

K Y

D V

A N

L O

O N

K B

R O

D B

E R

K B

R O

D B

E R

J U

L Y

W H

N B

- 7 -1

-2

C

A T

E G

O R

Y C

O D

E

F

IL

E N

A M

E A

E .D

W G

R E

A D

Y T

O A

D V

E R

T

IS

E

R T

A

3" = 1'-0"A1

WINDOW SILL DETAL

3" = 1'-0"A9

WINDOW SILL DETAIL

0 0.125' 0.25' 0.5' 0.75'

3" = 1'-0"A15

WINDOW SILL DETAIL

3" = 1'-0"L1

WINDOW HEAD DETAIL

3" = 1'-0"L9

WINDOW HEAD AND TYPICAL ROLLER

SHADE DETAIL

3" = 1'-0"L15

WINDOW HEAD DETAIL

3" = 1'-0"F1

WINDOW JAMB DETAILS

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

/1

/2

DVANLOON

Image

DVANLOON

Image

DVANLOON

TYPE WS4

STREET SIDE SHOWN (BALCONY SIDE, SIM)

3/4"

1"

INSULATED

GLAZING

NEW ALUMINUM

WINDOW

SYSTEM

NEW FLASHING

WITH STAINLESS

STEEL DRIP EDGE.

DO NOT BRIDGE

GAPS WITH

SUBSTRATE

SEALANT WITH

BACKER ROD

EXISTING STONE

WINDOW SILL

TREATED WOOD

SHIM AND

BLOCKING AS

NEEDED

EXISTING

MASONRY WALL

WITH FACE BRICK

PROVIDE SEALANT AT

PERIMETER AS REQUIRED

SECURE

WINDOW FRAME

TO STRUCTURAL

MTL STUDS

FLUID APPLIED

AIR BARRIER

SOLID SURFACE

WINDOW SILL

SEALANT

2 1/2" MTL STUDS

AT 24" O.C.

1" GAP/ MTL STUD

OFFSET FROM

EXISTING WALL

2" CLOSED CELL SPRAY

FOAM URETHANE AIR

BARRIER INSULATION TO

FILL 1" GAP CONTINUOUS

BEHIND MTL STUDS AND

1" OF STUD SPACE

TYPE WH4

STREET SIDE SHOWN (BALCONY SIDE, SIM)

1"

2" CLOSED CELL SPRAY

FOAM URETHANE AIR

BARRIER INSULATION

TO FILL 1" GAP

CONTINUOUS BEHIND

MTL STUDS AND 1" OF

STUD SPACE

1" GAP/ MTL STUD

OFFSET FROM

EXISTING WALL

5/8" TYPE-X

GYPSUM BOARD

ROLLER SHADE,

SEE TYPICAL

DETAIL L9/AE605

PROVIDE SEALANT

AT PERIMETER AS

REQUIRED

FACE BRICK

EXISTING STEEL

LINTEL PAINTED

SEALANT WITH

BACKER ROD

NEW FLASHING

WITH STAINLESS

STEEL DRIP EDGE.

DO NOT BRIDGE

GAPS WITH

SUBSTRATE

TREATED WOOD

SHIM AND

BLOCKING AS

REQUIRED

SECURE WINDOW

FRAME TO

STRUCTURAL STUDS

FLUID APPLIED

AIR BARRIER

2 1/2" MTL STUDS AT 24" O.C.

MUNTIN

INTERIOR

EXTERIOR

/8

NEW WINDOW SYSTEM

AS SCHEDULE

HORIZONTAL & VERTICAL

MULLION

TYPE WJ4

SEALANT WITH BACKER ROD

NEW ALUMINUM WINDOW

SYSTEM

INSULATED GLAZING UNIT

SOLID SURFACE WINDOW

SILL

2 1/2" MTL STUDS AT 24" O.C.

5/8" TYPE X GYPSUM BOARD

PROVIDE SEALANT AT

PERIMETER AS REQUIRED

SECURE WINDOW FRAME TO

STRUCTURAL STUDS

FLUID APPLIED AIR BARRIER

/4

1" GAP/ MTL STUD

OFFSET FROM

EXISTING WALL

2" CLOSED CELL SPRAY FOAM

URETHANE AIR BARRIER

INSULATION TO FILL 1" GAP

CONTINUOUS BEHIND MTL

STUDS AND 1" OF STUD SPACE

TREATED WOOD

SHIM AND BLOCKING

AS REQUIRED

F V

EXISTING

MASONRY WALL

WITH FACE BRICK

2"

EXISTING STEEL

LINTEL

EXISTING

MASONRY WALL

W/ FACE BRICK,

PATCH AND FINISH

AS REQUIRED

4" FV.

SEALANT AT

PERIMETER OF

FRAME

SHIM AS REQUIRED

SECURITY GRILLE

ANCHORED TO

LOUVER

FRAME AS

SCHEDULED

5/8" TYPE X

GYPSUM BOARD

LTTR-11.4 2"

POLYSOCYANURATE

RIGID INSULATION

ADHERED TO

STRUCTURE

1 5/8" MTL STUDS

AT 24" O.C.

NEW FLASHING WITH

STAINLESS STEEL

DRIP EDGE. DO NOT

BRIDGE GAPS WITH

SUBSTRATE

SEALANT WITH

BACKER ROD

FLUID APPLIED

AIR BARRIER

TYPE LH1

PRE-FINISHED METAL

DRAINABLE LOUVER

SECURE LOUVER

FRAME TO MASONRY

WALL AND MTL STUDS

TYPE LJ1

5/8" TYPE X

GYPSUM BOARD

LTTR-11.4 2"

POLYSOCYANURATE RIGID

INSULATION ADHERED TO

STRUCTURE

1 5/8" MTL STUDS

AT 24" O.C.

EXISTING MASONRY

WALL W/ FACE BRICK,

PATCH AND FINISH AS

REQUIRED

SEALANT WITH

BACKER ROD

PRE-FINISHED METAL

DRAINABLE LOUVER

SECURITY GRILL

ANCHORE TO LOUVER

SEALANT AT

PERIMETER OF

FRAME

FLUID APPLIED

AIR BARRIER

TREATED WOOD

SHIM AND BLOCKING

AS REQUIRED

SECURE LOUVER

FRAME TO MASONRY

WALL AND MTL STUDS

MULLION AS

INDICATED

TYPE LS1

PRE-FINISHED METAL

DRAINABLE LOUVER

2"

5/8" TYPE X

GYPSUM BOARD

LTTR-11.4 2"

POLYSOCYANURATE

RIGID INSULATION

ADHERED TO

STRUCTURE

1 5/8" MTL STUDS

AT 24" O.C.

FLUID APPLIED

AIR BARRIER

FLUID APPLIED

AIR BARRIER

SEALANT WITH

BACKER ROD

EXISTING STONE

WINDOW SILL

TREATED WOOD

SHIM AND

BLOCKING AS

NEEDED

EXISTING

MASONRY WALL

WITH FACE BRICK

NEW FLASHING WITH

STAINLESS STEEL DRIP

EDGE. DO NOT BRIDGE

GAPS WITH SUBSTRATE

SEALANT AT

PERIMETER OF FRAME

SECURITY GRILLE

ANCHORED TO LOUVER

DO NOT CAULK SILL

OF LOUVER

US Army Corps of Engineers ®

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

E O

R G

IA

JO

N

E S

F R

A N

K

LI

N R

D , S

U

IT

E

R A

LE

IG

H , N

C

-3

(9

1-

(9

1-

F

A X

LI

C

E N

S E

F

-0

F O

R T

B E

N N

IN

G

G

A B

U

IL

D

IN

G

T

R A

IN

E

E B

A R

R A

C K

S U

P G

R A

D E

P R

O G

R

U P

P

H A

S E

F

Y P

N

FOR OFFICIAL USE ONLY

AE606

W

IN

D O

W

L O

U V

E R

D E

T A

IL

S

A

T T

O W

E R

S

F A

C E

B R

IC

K

Z K

A S

K Y

D V

A N

L O

O N

K B

R O

D B

E R

K B

R O

D B

E R

J U

L Y

W H

N B

- 7 -1

-2

C

A T

E G

O R

Y C

O D

E

F

IL

E N

A M

E A

E .D

W G

R E

A D

Y T

O A

D V

E R

T

IS

E

R T

A

3" = 1'-0"A1

WINDOW SILL DETAIL - TOWERS

3" = 1'-0"L1

WINDOW HEAD DETAIL - TOWERS

0 0.125' 0.25' 0.5' 0.75'

3" = 1'-0"L15

TYPICAL MULLION & MUNTIN DETAILS

3" = 1'-0"F1

WINDOW JAMB DETAIL - TOWERS

3" = 1'-0"L8

DOOR HEAD DETAILS

3" = 1'-0"F8

DOOR HEAD DETAILS

3" = 1'-0"A8

DOOR HEAD DETAILS

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

/1

/2

DVANLOON

Image

DVANLOON

Image

DVANLOON

A. 20 GA STUDS AND BLOCKING IS REQUIRED WHERE WALL

HUNG CABINETS, COUNTERTOPS, AND APPLIANCES (IE: TV,

SMART BOARD, TACKBOARD, ETC.) OCCUR. OTHERWISE

GAUGE IS TO MEET MINIMUM PERFORMANCE OF WALL.

REFER TO AF, IF, AND MPE SERIES SHEETS FOR LOCATIONS

OF APPURTENANCES - TYPICAL

B. PROVIDE HORIZONTAL BRACING AS REQUIRED ABOVE

CEILING FOR 25 GA METAL STUDS SPACED 24 INCHES OC

THAT EXCEED LIMITING HEIGHT FACTOR PER MFR TABLES -

TYPICAL

C. ALL GYPSUM BOARD IS TO BE OFFSET 1/2" MIN FROM TOP

AND BOTTOM OF FLOOR SLABS, UNO - TYPICAL

D. AT SOUND ATTENUATION PARTITIONS, COORDINATE ALL

DUCT, CONDUITS, PIPES, AND CABLE TRAY PENETRATIONS.

PROVIDE ACOUSTICAL SEALANT AT PENETRATION

PERIMETER - TYPICAL

E. AT SOUND ATTENUATION PARTITIONS, SEAL PARTITIONS AT

BOTTOM (FLOOR SLAB) AND TOP (BOTTOM OF SLAB) -

TYPICAL

F. AT FIRE RATED PARTITIONS, COORDINATE DAMPER

LOCATIONS, AND ALL DUCT, CONDUITS, PIPES, AND CABLE

TRAY PENETRATIONS. PROVIDE FIRE STOPPING MATCHING

PARTITION RATING AT PENETRATION PERIMETERS - TYPICAL

G. AT CORRIDORS, STORAGE ROOMS, AND LAUNDRY ROOMS,

PROVIDE FULL HEIGHT 5/8" IMPACT, MOLD AND MILDEW

RESISTANT GYPSUM BOARD - TYPICAL

H. SEE STRUCTURAL SHEET S-503 FOR ADDITIONAL PARTITION

DETAILS AND INFORMATION

PARTITION TYPES NOTES:

SECTION

PLAN

FIRE RATING:

DESCRIPTION:

STC RATING:

UL DESIGN:

REMARKS:

PARTITION TYPE

1/2 HR RATED

CHASE WALL

1) FIRE STOP AND ACOUSTICAL SEAL

ALL PENETRATIONS; 2) SEE INTERIOR

ELEVATIONS FOR TILE HEIGHTS

1"=1'-0"

CEILING AS

SCHEDULED

BOTTOM

EXIST. SLAB

CERAMIC TILE

BASE AS

SCHEDULED

FINISH FLOOR AS

SCHEDULED

3-5/8" METAL STUDS

25 GA AT 16" OC

3-1/2" SOUND

ATTENUATION FIRE

BATT (SAFB)

5/8" CEMENTITIOUS

BACKER BD

CONT FIRE SAFING

SEALANT AT TOP &

BOTTOM

CONT

RUNNERS - SLIP

CONNECTION

CERAMIC WALL TILE

AS SCHEDULED

SEE FLOOR PLANS

VARIES

S E

E F

L O

O R

P L A

N S

V A

R

IE

S

3-5/8" METAL STUDS

25 GA AT 16" OC

3-1/2" SOUND

ATTENUATION

FIRE BATT (SAFB)

5/8" CEMENTITIOUS

BACKER BD CERAMIC WALL

TILE AS

SCHEDULED

CONT RUNNER

CEILING AS

SCHEDULED

BOTTOM

EXIST. SLAB

BASE AS

SCHEDULED

FINISH FLOOR AS

SCHEDULED

SECTION

PLAN

4" C-H STUDS 25 GA

(400CH-34) AT 24" OC

VERTICAL

3" SOUND

ATTENUATION FIRE

BATT (SAFB)

5/8" TYPE X HIGH IMPACT

MOLD AND

MILDEW RESISTANT GYP

BD

CONT FIRE SAFING

SEALANT AT TOP &

BOTTOM

CONT J-RUNNERS

FIRE RATING:

DESCRIPTION:

STC RATING:

UL DESIGN:

REMARKS:

PARTITION TYPE

1 HR RATED

SHAFT WALL

U415

4" C-H STUD, 4" J-STUD

1"=1'-0"

T O

/8

M

IN

M A

X

SHAFT

CONT J-RUNNERS

1" GYP LINER

PANEL

3" SOUND

ATTENUATION FIRE

BATT (SAFB)

5/8" TYPE X HIGH IMPACT

MOLD AND

MILDEW RESISTANT GYP

BD

1" GYP LINER

PANEL

4" C-H STUDS 25 GA

(400CH-34) AT 24" OC

VERTICAL

SHAFT

CEILING AS

SCHEDULED

BOTTOM

EXIST. SLAB

BASE AS

SCHEDULED

FINISH FLOOR AS

SCHEDULED

SECTION

PLAN

3-5/8" METAL STUDS

25 GA AT 24" OC

5/8" TYPE X HIGH

IMPACT MOLD AND

MILDEW RESISTANT

GYP BD

CONT SEALANT AT

BOTTOM

CONT RUNNERS -

SLIP CONNECTION

FIRE RATING:

DESCRIPTION:

STC RATING:

UL DESIGN:

REMARKS:

PARTITION TYPE

METAL STUD WALL, (1) LAYER GYP BD

3-5/8" METAL STUDS

1"=1'-0"

3-5/8" METAL STUDS

25 GA AT 24" OC

5/8" TYPE X HIGH IMPACT

MOLD AND

MILDEW RESISTANT GYP

BD

CONT RUNNER

M

IN6

FIRE RATING:

DESCRIPTION:

STC RATING:

UL DESIGN:

REMARKS:

PARTITION TYPE

09A

METAL STUD WALL, (1) LAYER GYP BD

3-5/8" METAL STUDS, CERAMIC WALL

TILE

1"=1'-0"

09: 5/8" TYPE X HIGH

IMPACT MOLD AND

MILDEW RESISTANT GYP

BD

09A: 5/8" CEMENTITIOUS

BACKER BD

09A: CERAMIC WALL

TILE AS SCHEDULED

09: BASE AS

SCHEDULED

09A: CERAMIC BASE

AS SCHEDULED

09: 5/8" TYPE X HIGH

IMPACT MOLD AND

MILDEW RESISTANT GYP

BD

09A: 5/8" CEMENTITIOUS

BACKER BD

09A: CERAMIC WALL

TILE AS SCHEDULED

CEILING AS

SCHEDULED

BOTTOM

EXIST. SLAB

BASE AS

SCHEDULED

FINISH FLOOR AS

SCHEDULED

SECTION

PLAN

2-1/2" COLD FORMED

METAL STUDS 25 GA

AT 24" OC

5/8" TYPE X HIGH IMPACT

MOLD AND MILDEW

RESISTANT GYP BD

CONT SEALANT AT

TOP & BOTTOM AND

WALL PERIMETER

CONT RUNNERS -

SLIP CONNECTION

FIRE RATING:

DESCRIPTION:

STC RATING:

UL DESIGN:

REMARKS:

PARTITION TYPE

2-1/2" METAL STUD WALL FURRING

EXTERIOR PERIMETER WALL

1"=1'-0"

CONT RUNNER

EXIST EXTERIOR

PERIMETER WALL

ASSEMBLY

2-1/2" COLD FORMED

METAL STUDS 25 GA

AT 24" OC

5/8" TYPE X HIGH

IMPACT MOLD AND

MILDEW

RESISTANT GYP BD

EXIST EXTERIOR

PERIMETER WALL

ASSEMBLY

CLOSED CELL SPRAY

FOAM URETHANE AIR

BARRIER INSULATION

1"

2" MIN

CLOSED CELL SPRAY

FOAM URETHANE AIR

BARRIER INSULATION

M

IN

PROVIDE HORIZONTAL

BRACING AS REQUIRED

CEILING AS

SCHEDULED

BOTTOM

EXIST. SLAB

11: BASE AS SCHEDULED

11A: CERAMIC BASE AS

SCHEDULED

FINISH FLOOR AS

SCHEDULED

SECTION

PLAN

3-5/8" METAL STUDS

25 GA AT 24" OC

11: 5/8" TYPE X HIGH

IMPACT MOLD AND

MILDEW RESISTANT GYP

BD

11A: 5/8" CEMENTITIOUS

BACKER BD

CONT SEALANT AT

BOTTOM

CONT RUNNERS -

SLIP CONNECTION

FIRE RATING:

DESCRIPTION:

STC RATING:

UL DESIGN:

REMARKS:

PARTITION TYPE

METAL STUD CHASE WALL

3-5/8" METAL STUDS

1"=1'-0"

CONT RUNNER

EXISTING WALL

3-5/8" METAL STUDS

25 GA AT 24" OC

EXIST WALL

SEE FLOOR PLAN

VARIES

S E

E F

L O

O R

P L

A N

V A

R

IE

S

M

IN6

FIRE RATING:

DESCRIPTION:

STC RATING:

UL DESIGN:

REMARKS:

PARTITION TYPE

11A

METAL STUD CHASE WALL

3-5/8" METAL STUDS, CERAMIC WALL

TILE

1"=1'-0"

11A: CERAMIC WALL

TILE AS SCHEDULED

11: 5/8" TYPE X HIGH

IMPACT MOLD AND

MILDEW RESISTANT GYP

BD

11A: 5/8" CEMENTITIOUS

BACKER BD

11A: CERAMIC WALL

TILE AS SCHEDULED

CEILING AS

SCHEDULED

BOTTOM

EXIST. SLAB

CERAMIC BASE

AS SCHEDULED

FINISH FLOOR AS

SCHEDULED

SECTION

PLAN

2-1/2" COLD FORMED

METAL STUDS 25 GA

AT 24" OC

5/8" CEMENTITIOUS

BACKER BD

CONT SEALANT AT

TOP & BOTTOM AND

WALL PERIMETER

CONT RUNNERS -

SLIP CONNECTION

FIRE RATING:

DESCRIPTION:

STC RATING:

UL DESIGN:

REMARKS:

PARTITION TYPE

2-1/2" METAL STUD WALL FURRING

EXTERIOR PERIMETER WALL W/

CERAMIC WALL TILE

1"=1'-0"

CONT RUNNER

EXIST EXTERIOR

PERIMETER WALL

ASSEMBLY

2-1/2" COLD FORMED

METAL STUDS 25 GA

AT 24" OC

5/8" CEMENTITIOUS

BACKER BD

EXIST…