W912HN-20-B-3013_VOL2_AMD2.pdf
PDF 299 KB Posted
- Attached to
- PN91397 Field Research Facility Annex
- Solicitation number
- W912HN20B3013
About this file
This document package includes structural notes and details for a federal construction project solicitation. The solicitation is for the construction of a 4,008 square foot Field Research Facility Annex in Duck, North Carolina, to include offices, meeting rooms, and mechanical and electrical support spaces. Response is requested as a sealed bid in accordance with FAR Part 14. The estimated value of construction is between $1,000,000 and $5,000,000. Bidders must be registered in the System for Award Management. The contracting point of contact is provided as Ms. Tonja Dreke of the U.S. Army Corps of Engineers in Savannah, Georgia. The structural notes and details specify requirements for concrete construction, masonry, steel components, and prestressed concrete piles for the project.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Bid Opening Log.pdf | ||
| Bid Opening Chat.pdf | ||
| C.04 Abstract_W912HN20B3013 Duck NC FRF Annex.pdf | ||
| W912HN-20-B-3013_VOL1_AMD2.pdf | ||
| 20B3013vol1.pdf | ||
| W912HN20B30130002.pdf | ||
| W912HN20B30130001.pdf | ||
| 20B3013vol2.pdf | ||
| 20B3013vol1.pdf | ||
| FRF Annex Pre-Bid Site Visit.pdf | ||
| 20B3013vol2.pdf | ||
| 20B3013vol3.pdf | ||
| 20B3013vol1.pdf | ||
| W912HN-20-B-3013_VOL2.pdf | ||
| W912HN-20-B-3013_VOL1.pdf |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STRUCTURAL ABBREVIATIONS
SYMBOL DESCRIPTION
AFF ABOVE FINISHED FLOOR
APPROX APPROXIMATELY
ARCH ARCHITECTURAL
BOC BOTTOM OF CONCRETE
BOF BOTTOM OF FOOTING
BOM BOTTOM OF MASONRY
BOS BOTTOM OF STEEL
BOT BOTTOM
BRG BEARING
BTWN BETWEEN
CJ CONSTRUCTION JOINT
CL CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONN CONNECTION
CONC CONCRETE
CONT CONTINUOUS
CONSTR CONSTRUCTION
DCJ DOWELED CONSTRUCTION JOINT
DEG DEGREE
DIA DIAMETER
DN DOWN
DWG(S) DRAWING(S)
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
EOS EDGE OF SLAB
ES EACH SIDE
EQ EQUAL
EW EACH WAY
FF FINISHED FLOOR
FTG FOOTING
GA GAUGE
GALV GALVANIZED
GOVT GOVERNMENT
HORIZ HORIZONTAL
IJ ISOLATION JOINT
KIP (k) 1000 POUNDS
LG LONG
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
MAX MAXIMUM
MB METAL BUILDING
MBF METAL BUILDING MANUFACTURER
MCJ MASONRY CONTROL JOINT
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL, PLUMBING
MFR MANUFACTURER
MIN MINIMUM
NTS NOT TO SCALE
OC ON CENTER
OPP OPPOSITE
PJF PREMOLDED JOINT FILLER
PL PLATE
PLF POUNDS PER LINEAR FOOT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
RAD RADIUS
REINF REINFORCEMENT
REQD REQUIRED
SCHED SCHEDULE
SE SLAB EDGE
SJ SAWED CONTRACTION JOINT
SJI STEEL JOIST INSTITUTE
SIM SIMILAR
SL SLOPE(D)
SOG SLAB ON GRADE
SPCG SPACING
STD STANDARD
T&B TOP AND BOTTOM
TO TOP OF
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOS TOP OF STEEL
TS THICKENED SLAB
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
WP WORKING POINT
WWF WELDED WIRE FABRIC
STRUCTURAL LEGEND
SLOPE DIRECTION
INDICATES ELEVATION REFERENCED
TO FINISHED FLOOR
KEYED PLAN NOTE
COLUMN REFERENCE LINE
(CENTER LINE OF COLUMN)
SPOT ELEVATION
SLAB DEPRESSION
BRICK WALL
CONCRETE ELEMENT
EARTH FILL
GROUT
CONCRETE MASONRY UNIT (CMU)
POROUS FILL
WELDED WIRE FABRIC (WWF)
STEEL FRAMING REFERENCE
WXxXX
DN
X
[+/- X’-X”]
X
[+/- X’-X”]
AISC SHAPE
DESIGNATION
HSSXxX AISC COLUMN
DESIGNATION
STEEL COLUMN
BF#X
BRACED/MOMENT
FRAME NUMBER
BRACED FRAME
DESIGNATION
MOMENT FRAME
DESIGNATION
STEEL JOIST NOTES:
SJ-1. DESIGN, FABRICATION AND ERECTION OF JOISTS, JOIST EXTENSIONS AND JOIST
SUBSTITUTES SHALL BE IN ACCORDANCE WITH SJI SPECIFICATIONS.
SJ-2. ALL ROOF JOISTS, JOIST EXTENSIONS AND JOIST SUBSTITUTES SHALL BE DESIGNED BY THE
STEEL JOIST FABRICATOR FOR THE DESIGN LOADS NOTED ON THE DRAWINGS INCLUDING:
1. ROOF COLLATERAL DEAD LOAD OF 15 PSF
ROOF COLLATERAL DEAD LOAD OF 7 PSF FOR UPLIFT CALCULATIONS
2. ROOF LIVE LOAD OF 20 PSF WITH LIVE LOAD DEFLECTION LESS THAN L/360.
MAXIMUM DEFLECTION FOR D+L = L/360.
3. NET UPLIFT PRESSURES, GROSS UPLIFT PRESSURES INDICATED ON S-003.
4. POSITIVE WIND PRESSURES INDICATED ON S-003.
5. JOISTS SHALL BE DESIGNED FOR LOAD COMBINATIONS REQUIRED BY IBC, ASCE,
AND UFC.
SJ-3. JOISTS, JOIST EXTENSIONS AND JOIST SUBSTITUTES SHALL BE DESIGNED TO THE
INDICATED SLOPES AND FOLLOWING CRITERIA. ROOF JOISTS SIZES SHOWN ON DRAWINGS
ARE PROVIDED FOR ESTIMATING PURPOSES, HOWEVER SHALL BE MINIMUM REQUIRED AND
ANY CHANGE REQUIRED SHALL BE SUBJECT TO CONTRACTING OFFICER APPROVAL.
SJ-4. JOIST DESIGN SHALL INCLUDE ALL REQUIRED JOIST BRIDGING. BRIDGING SHALL BE SIZED, SPACED, AND INSTALLED IN ACCORDANCE WITH SJI SPECIFICATIONS.
SJ-5. PROVIDE TOP AND BOTTOM CHORD EXTENSIONS WHERE NOTED ON DRAWINGS.
SJ-6. DO NOT CAMBER JOISTS.
SJ-7. CALCULATIONS AND DRAWINGS PREPARED AND SIGNED BY A REGISTERED ENGINEER
SHALL BE SUBMITTED TO THE ENGINEER OF RECORD FOR REVIEW PRIOR TO FABRICATION
OF JOISTS.
SJ-8. JOISTS SHALL BE CONNECTED TO THE SUPPORTING STEEL IN ACCORDANCE WITH SJI
SPECIFICATIONS AND PROJECT CRITERIA NOTED ON DRAWINGS.
SJ-9. SWAY (DIAGONAL BRACING FRO SUSPENDED MECHANICAL EQUIPMENT SHALL ATTACH TO
THE TOP CHORD OF THE JOISTS AND NOT THE BOTTOM CHORD.
STEEL DECK NOTES:
SD-1. ROOF DECK SHALL BE GALVANIZED STEEL CONFORMING TO ASTM A653 WITH A MINIMUM
YIELD STRENGTH OF 33 KSI. STEEL ROOF DECK SHALL BE AS SHOWN ON DRAWINGS.
FASTENERS FOR ROOF DECK SHALL UTILIZE 5/8" DIA PUDDLE WELDS AT A 36/4 PATTERN TO
SUPPORT STRUCTURE AND A MINIMUM OF (4) #10 SELF TAPPING SCREWS AT SIDE LAP
CONNECTIONS.
SD-2. PROVIDE ALL RIDGE PLATES, VALLEY PLATES, CLOSURE PLATES, POUR STOPS, AND ALL
OTHER ACCESSORIES REQUIRED FOR COMPLETE INSTALLATION IN ACCORDANCE WITH THE
DECK MANUFACTURER'S RECOMMENDATIONS.
SD-3. CONTRACTOR SHALL COORDINATE OPENINGS IN STEEL DECK WITH ARCHITECTURAL,
MECHANICAL, AND ELECTRICAL DRAWINGS PRIOR TO DECK PLACEMENT.
SD-4. HANGING LOADS DIRECTLY FROM ROOF DECK IS PROHIBITED.
SD-5. STEEL DECK SHALL SPAN CONTINUOUSLY OVER A MINIMUM OF 4 SUPPORTS (3 SPANS) UNO.
STEEL CONSTRUCTION NOTES:
S-1. FABRICATION AND ERECTION OF STRUCTURAL STEEL AND DESIGN OF CONNECTIONS SHALL BE IN
ACCORDANCE WITH AISC 360-16, "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" AND
AISC 303-16, "CODE OF STANDARD PRACTICE FOR BUILDING AND BRIDGES". THE STRUCTURAL STEEL MEMBERS SHOWN IN THESE DRAWINGS HAVE BEEN ANALYZED AND DESIGNED USING AISC 360-16, LRFD METHOD.
S-2. UNLESS OTHERWISE NOTED, STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH THE ABOVE-
LISTED AISC SPECIFICATION AND THE FOLLOWING:
A. WIDE FLANGE SHAPES (50 KSI) ASTM A992
B. HSS HOLLOW SHAPES (46 KSI) ASTM A500, GRADE B
B. PLATES AND ANGLES ASTM A36
C. HIGH STRENGTH BOLTS ASTM F3125
D. ANCHOR RODS W/ NUT AND WASHER ASTM F1554, GRADE 36
S-3. "ORDINARY CONCENTRICALLY BRACED FRAMES" ARE USED IN THE LATERAL FORCE RESISTING
SYSTEM.
S-4. ALL SHOP AND FIELD WELDING SHALL BE BY CERTIFIED WELDERS AND SHALL CONFORM TO AWS
STANDARDS. USE E70XX ELECTRODES UNLESS OTHERWISE NOTED. MINIMUM WELD SIZE FOR
STRUCTURAL STEEL IS 3/16 IN FILLET, UNLESS OTHERWISE NOTED. CURRENT AWS CERTIFICATIONS
SHALL BE AVAILABLE AT THE JOB SITE FOR REVIEW BY THE OWNERS' REPRESENTATIVE.
S-5. ALL BOLTED CONNECTIONS, UNLESS OTHERWISE NOTED, SHALL USE 3/4" DIAMETER HIGH STRENGTH
BOLTS WITH HARDENED CARBON STEEL WASHERS.
S-6. ALL FIELD-BOLTED SHEAR CONNECTIONS SHALL BE SNUG TIGHT BEARING-TYPE CONNECTIONS, THREADS INCLUDED IN THE SHEAR PLANE.
S-7. FIELD CUTTING OF STRUCTURAL STEEL MEMBERS BY ANY TRADE IS NOT PERMITTED. BOLT HOLES
SHALL NOT BE CUT OR ENLARGED BY FLAME CUTTING IN THE FIELD.
S-8. THE CONTRACTOR SHALL SUBMIT FOR APPROVAL DRAWINGS AND DESIGN CALCULATIONS FOR ANY
ALTERNATE DETAILS AND MEMBER SPLICES.
S-9. SHOP OR FIELD SPLICES OF STRUCTURAL STEEL MEMBERS ARE PROHIBITED EXCEPT AS DETAILED ON THE DRAWINGS, PERMITTED IN THE SPECIFICATIONS, AS INDICATED ON APPROVED SUBMITTALS, AND AS SPECIFICALLY APPROVED ON SHOP DRAWINGS PRIOR TO FABRICATION.
S-10. SPLICE PERIMETER BENT PLATE DECK CLOSURE DIRECTLY ABOVE A SUPPORTING STRUCTURAL
STEEL MEMBER.
S-11. ALL STEEL EXPOSED TO WEATHER SHALL BE HOT-DIPPED GALVANIZED IN ACCORDANCE WITH ASTM A123 FOR MEMBERS AND ASTM A153 FOR CONNECTION ELEMENTS, EXCEPT THAT ARCHITECTURALLY EXPOSED STRUCTURAL STEEL SHALL BE BLAST CLEANED AND COATED IN ACCORDANCE WITH THE
STRUCTURAL STEEL AND PAINT SPECIFICATIONS. COORDINATE ALL STEEL FINISHES WITH
ARCHITECTURAL DRAWINGS AND SPECIFICATIONS.
MASONRY CONSTRUCTION NOTES:
M-1. ALL MASONRY CONSTRUCTION SHALL BE IN ACCORDANCE WITH "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES" (TMS 402-16) AND "SPECIFICATION FOR MASONRY STRUCTURES" (TMS 602-16).
M-2. DESIGN MASONRY ASSEMBLAGE STRENGTH, f'm = 2000 PSI.
M-3. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 AND BE MANUFACTURED WITH EITHER LIGHTWEIGHT OR NORMAL WEIGHT AGGREGATE. NET AREA COMPRESSIVE STRENGTH OF CONCRETE
MASONRY UNITS SHALL BE A MINIMUM OF 2650 PSI.
M-4. GROUT SHALL CONFORM TO ASTM C476 AND SHALL NOT CONTAIN ADMIXTURES. GROUT SHALL ATTAIN
A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 2000 PSI.
M-5. REINFORCEMENT SHALL BE DEFORMED BARS CONFORMING TO ASTM A615/A615M, GRADE 60 AND
SHALL HAVE FABRICATION TOLERANCES IN ACCORDANCE WITH ACI 315. SHOP FABRICATE
REINFORCING BARS WHICH ARE INDICATED TO BE BENT OR HOOKED.
M-6. LOCATE JOINT REINFORCEMENT 16 INCHES ON CENTER VERTICALLY AND ADDITIONALLY AT THE TOP OF ALL FOUNDATIONS AND IN THE TWO JOINTS IMMEDIATELY ABOVE AND BELOW ALL OPENINGS, EXTENDING A MINIMUM OF 24 INCHES BEYOND THE JAMB ON EACH SIDE.
M-7. PLACE PIPES AND CONDUITS PASSING HORIZONTALLY THROUGH MASONRY IN STEEL OR PVC SLEEVES
OR CORED HOLES UNLESS OTHERWISE INDICATED ON THE DRAWINGS.
M-8. ALUMINUM CONDUITS, PIPES, AND ACCESSORIES SHALL NOT BE EMBEDDED IN MASONRY GROUT, OR
MORTAR, UNLESS EFFECTIVELY COATED OR COVERED TO PREVENT ALUMINUM-CEMENT CHEMICAL
REACTION OR ELECTROLYTIC REACTION BETWEEN ALUMINUM AND STEEL.
M-9. UNLESS OTHERWISE NOTED OR DETAILED, CENTER WALL REINFORCEMENT IN BLOCK CELLS. USE
NONMETALLIC BAR POSITIONERS.
M-10. PROVIDE DOWEL REINFORCEMENT FROM WALLS INTO FOUNDATION OF SAME SIZE AND SPACING AS VERTICAL WALL REINFORCEMENT. LAP WALL REINFORCEMENT AS INDICATED IN SCHEDULE ON SF601.
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXCTA\Desktop\Tele-Work Revit Projects\Bsu001 (PN91397)\FY20PN91397_STRUC_R18_TW Current.rvt9/4/2020 10:21:10 AM
JU
LY
W
2H N
-2 0-
B-
C . A
TK
IN
S
C . A
TK
IN
S
S.
B
AR
BI
N A
0-
-0
S-002
G
EN
ER
AL
S
TR
U C
TU
R
AL
N
O
TE
S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
D U
C K, N O
R
TH
C
AR
O
LI
N A
FI
EL
D R
ES
EA
R C
H F
AC
IL
IT
Y
AN
N
EX
FY
, P
N
VO
LU
M E
-B
U
IL
D
IN
G
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
SE
P
2 0
CLR
3"2'
0"
8"
TY
P
2" C
LR
TY
P 2"
C
LR
(4) #6 BOT
#4 STIRRUPS @ 3" OC, 0'-0" - 1'-0"
#4 STIRRUPS @ 6" OC, 1'-0" - 4'-0"
#4 STIRRUPS @ 9" OC, 4'-0" - CENTER
DISTANCES FROM EF OF PILE
(3) #6 TOP,
(1) ADD #6 TOP AT CANTILEVER BEAMS
#5 @ 12" OC EW T&B,
BOTTOM MOST AND TOP MOST BARS
SPAN PLAN NORTH - PLAN SOUTH
#4 CROSS-TIE @ 12" OC MAX,
HOOK EACH END
2' - 0"
CL
C
LR3"
C
LR4"
8"
1' - 6"
2'
1"
STIRRUP
TOC
SEE PLAN
T/BEAM
SEE PLAN
C
LR
1/
2"
CL
1/2 PREMOLDED JOINT FILLER
INTERIOR CONCRETE SLAB,
SEE PLAN NOTES
RIGID INSULATION
CMU WALL, SEE PLAN
AND SCHEDULE
VERTICAL DOWEL TO MATCH WALL
REINFORCEMENT SIZE AND SPACING,
LAP SPLICE PER CMU SPLICE LENGTH
SCHEDULE VAPOR RETARDER
ELEVATED DECK EXTERIOR TO
BUILDING SLOPES APPROX 1/8" PER 12"
AWAY FROM BUILDING, SLOPE IS
FORMED BY TOP OF BEAM ELEVATIONS
PROVIDE #5 X 3'-0" LONG MIN
BENT BAR AT SLOPE CHANGE,
TOP AND BOTTOM, MATCH
PRIMARY REINF SPACING
0" C
LR
0"
C
LR
CL
1/2" PREMOLDED JOINT FILLER
SEE SF506 FOR BASE PLATE AND
ANCHOR BOLT INFORMATION
(2) #4 STIRRUPS @ 6" OC
CENTERED ABOVE PILE
PRESTRESSED CONCRETE PILE,
SEE 3/SF501 AND SPECIFICATION
FOR INFORMATION
CL
(4) #6 DOWEL W/ 90 DEG STD HOOK,
6" MIN EMBED, EPOXY GROUTED
(1) #6 EF X 4'-0" LONG
DISCONTINUE (4) BEAM BOTTOM BARS
AT PILE, NOT SHOWN
1'
/2
1' - 6"
C
LR4"
180 DEG HOOK
STIRRUP
TOC
SEE PLAN
T/BEAM
SEE PLAN
6" M
IN
3"
M
IN
CLR
3"2'
0"
8"
TY
P
2" C
LR
TY
P 2"
C
LR
(4) #6 BOT
#4 STIRRUPS @ 3" OC, 0'-0" - 1'-0"
#4 STIRRUPS @ 6" OC, 1'-0" - 4'-0"
#4 STIRRUPS @ 9" OC, 4'-0" - CENTER
DISTANCES FROM FACE OF
INTERSECTING BEAM
(3) #6 TOP,
(1) ADD #6 TOP AT CANTILEVER BEAMS
#5 @ 12" OC EW T&B,
BOTTOM MOST AND TOP MOST BARS
SPAN PLAN NORTH - PLAN SOUTH
#4 CROSS-TIE @ 12" OC MAX,
HOOK EACH END
2' - 0"
CL
C
LR4"
C
LR4"
8"
1' - 6"
2'
0"
STIRRUP
TRANSVERSE CONCRETE BEAMS SPAN
PLAN NORTH - PLAN SOUTH
TOC
SEE PLAN
T/BEAM
SEE PLAN
C
LR
1/
2"
CLR
3"
(2) #6 BOT, CONT THRU CANTILEVER
#4 STIRRUPS @ 3" OC, 0'-0" - 1'-0"
#4 STIRRUPS @ 6" OC, 1'-0" - 4'-0"
#4 STIRRUPS @ 9" OC, 4'-0" - CENTER
DISTANCES FROM FACE OF
INTERSECTING CANTILEVER BEAM
(2) #6 TOP, CONT THRU CANTILEVER
#5 @ 12" OC EW T&B,
BOTTOM MOST AND TOP MOST BARS
SPAN PLAN NORTH - PLAN SOUTH
1' - 0"
CL
C
LR3"
6"
1'
/2
STIRRUP
TY
P
2" C
LR
9"
TY
P
2" C
LR
C
LR4"
TOC
SEE PLAN
T/BEAM
SEE PLAN
1'
/2 " C
LR2"
CLR
3"
(4) #6 BOTTOM
#4 STIRRUPS @ 3" OC, 0'-0" - 1'-0"
#4 STIRRUPS @ 6" OC, 1'-0" - 4'-0"
#4 STIRRUPS @ 9" OC, 4'-0" - CENTER
DISTANCES FROM EF OF PILE
(3) #6 TOP
#5 @ 12" OC EW T&B,
BOTTOM MOST AND TOP MOST BARS
SPAN PLAN NORTH - PLAN SOUTH
#4 CROSS-TIE @ 12" OC MAX,
HOOK EACH END
2' - 0"
CL
C
LR3"
1' - 6"
1'
/2
STIRRUP
TY
P
2" C
LR
1' - 3"
TY
P
2" C
LR
C
LR4"
TOC
SEE PLAN
T/BEAM
SEE PLAN
1'
/2 " C
LR
1/ 2"
CLR
3"
(2) #6 BOT, CONT THRU CANTILEVER
#4 STIRRUPS @ 3" OC, 0'-0" - 1'-0"
#4 STIRRUPS @ 6" OC, 1'-0" - 4'-0"
#4 STIRRUPS @ 9" OC, 4'-0" - CENTER
DISTANCES FROM FACE OF
INTERSECTING CANTILEVER BEAM
(2) #6 TOP, CONT THRU CANTILEVER
#5 @ 12" OC EW T&B,
BOTTOM MOST AND TOP MOST BARS
SPAN PLAN NORTH - PLAN SOUTH
1' - 0"
CL
C
LR3"
6"
1'
/2
STIRRUP
9"
C
LR4"
TOC
SEE PLAN
T/BEAM
SEE PLAN
1'
/2
"TY
P 2"
C
LR
TY
P
2" C
LR
EXISTING DECK
CLR
1/2"
C
LR2"
NOTE:
AT SIMILAR, GALVANIZED GUARDRAIL,
NO EXISTING DECK
12"
14"
3" COVER
3" COVER
SECTION
12" x 12" OPTION
FOR BID PURPOSES ONLY
ALTERNATE STRAND PATTERNS ACCEPTABLE
SECTION
14" x 14" OPTION
FOR BID PURPOSES ONLY
ALTERNATE STRAND PATTERNS ACCEPTABLE
3/4" CHAMFER MIN 3/4" CHAMFER MIN
FINAL PILE SIZE SHALL BE DETERMINED BY THE CONTRACTOR'S PRESTRESSED CONCRETE PILE MFR PREDICATED ON THE LOADING AND DRIFT LIMIT CRITERIA ON S-001 AND SPECIFICATION 31 62 13.20
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXCTA\Desktop\Tele-Work Revit Projects\Bsu001 (PN91397)\FY20PN91397_STRUC_R18_TW Current.rvt9/4/2020 10:21:18 AM
JU
LY
W
2H N
-2 0-
B-
C . A
TK
IN
S
C . A
TK
IN
S
S.
B
AR
BI
N A
0-
-0
SF501
EL
EV
AT
ED
D
EC
K D
ET
AI
LS
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
D U
C K, N O
R
TH
C
AR
O
LI
N A
FI
EL
D R
ES
EA
R C
H F
AC
IL
IT
Y
AN
N
EX
FY
, P
N
VO
LU
M E
-B
U
IL
D
IN
G
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
ELEVATED DECK, CONCRETE BEAM1
ELEVATED DECK, EXTERIOR MASONRY WALL9ELEVATED DECK, INTERIOR STEEL COLUMN8
0' 1' 2' 3'
SCALE: 1" = 1' - 0"
0' 1' 2' 3'
SCALE: 1" = 1' - 0"
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
SE
P
2 0
ELEVATED DECK, CONCRETE BEAM OVER PILE2
0' 1' 2' 3'
SCALE: 1" = 1' - 0"
0' 1' 2' 3'
SCALE: 1" = 1' - 0"
0' 1' 2' 3'
SCALE: 1" = 1' - 0"
0' 1' 2' 3'
SCALE: 1" = 1' - 0"
ELEVATED DECK, TRANSVERSE CONCRETE BEAM4
0'
SCALE: 1-1/2" = 1' - 0"
1' 2'
0' 1' 2' 3'
SCALE: 1" = 1' - 0"
0' 1' 2' 3'
SCALE: 1" = 1' - 0"
ELEVATED DECK, PERIMETER BEAM5 ELEVATED DECK, PERIMETER BEAM6
ELEVATED DECK, PERIMETER BEAM7
PRESTESSED CONCRETE PILE DETAILS3
| S-002 GENERAL STRUCTURAL NOTES |
| SF501 ELEVATED DECK DETAILS |