W912HN-20-B-3013_VOL1_AMD2.pdf
PDF 299 KB Posted
- Attached to
- PN91397 Field Research Facility Annex
- Solicitation number
- W912HN20B3013
About this file
This solicitation is for the construction of a 4,008 square foot Field Research Facility Annex at Duck, North Carolina. The project scope includes offices, administrative support areas, team room, secure meeting room, support shop space, restrooms, janitor closet, telecommunications room, electrical room and mechanical room. The facility will include building information systems, NIPR and SIPR networks, and fire detection and alarm systems. This is a 100% competitive small business set-aside solicitation issued by the Department of the Army Corps of Engineers Engineering District Savannah under NAICS code 236220. Bids are due in accordance with FAR Part 14 governing sealed bidding. The estimated value of construction is between $1 million and $5 million. Bidders must be registered in the System for Award Management. The point of contact listed for questions is Ms. Tonja Dreke of the Savannah District.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Bid Opening Log.pdf | ||
| Bid Opening Chat.pdf | ||
| C.04 Abstract_W912HN20B3013 Duck NC FRF Annex.pdf | ||
| W912HN-20-B-3013_VOL2_AMD2.pdf | ||
| 20B3013vol1.pdf | ||
| W912HN20B30130002.pdf | ||
| W912HN20B30130001.pdf | ||
| 20B3013vol2.pdf | ||
| 20B3013vol1.pdf | ||
| FRF Annex Pre-Bid Site Visit.pdf | ||
| 20B3013vol2.pdf | ||
| 20B3013vol3.pdf | ||
| 20B3013vol1.pdf | ||
| W912HN-20-B-3013_VOL2.pdf | ||
| W912HN-20-B-3013_VOL1.pdf |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
X
X X
S
X
A CUSED
B-NOT
J
SCIENTIST ROAD
H
IG
H W
A Y /D
U C
K R
O A
D
6 6
KEYED NOTES:
30' 30' 60'
SCALE: 1" = 30'
NOTES
N
AND GENERAL NOTES.
1. SEE SHEET ES001 FOR LEGEND, ABBREVIATIONS
CROSSINGS.
THE LOCAL JURISDICTION AUTHORIZING THE HIGHWAY
ATTAINING APPLICABLE PERMITS FROM NC DOT AND
BLE FOR SUBMITTING APPLICATION FORMS AND
DIRECTIONAL BORED. THE CONTRACTOR IS RESPONSI
6. ELECTRICAL CONDUIT UNDER THE HIGHWAY MAY BE
DETAIL.
5. SEE ES502 FOR ELECTRICAL SECONDARY CONDUIT
DISCONNECT SWITCH DETAIL.
BACKFLOW PREVENTER ENCLOSURE. SEE ES501 FOR
BACKFLOW PREVENTERS AND CU501 FOR
RECOMMENDATIONS. SEE CU102 FOR LOCATION OF
ACCORDANCE WITH THE MANUFACTURER'S
TERMINATE CONNECTIONS FOR HEAT TRACE SYSTEM IN
HEAT SYSTEM. THE CONTRACTOR TO TRIM AND
ADJACENT TO JUNCTION BOX FOR QUICK CONNECT TO
CONNECTIONS. PROVIDE A GFCI RECEPTACLE
ENCLOSURE FOR 2000 WATT HEAT SYSTEM
4. PROVIDE A JUNCTION BOX INSIDE ABOVE GROUND
DISCONNECT SWITCH DETAIL.
FOR 2000 WATT" HEAT SYSTEM. SEE ES501 FOR
3. DISCONNECT SWITCH (DS-HTS) SHALL BE PROVIDED
FOR DISCONNECT SWITCH DETAIL.
DISCONNECT SWITCH TO JUNCTION BOX. SEE ES501
PANELBOARD TO DISCONNECT SWITCH AND FROM
CONDUITS SHALL RUN UNDERGROUND FROM EXISTING
2. PROVIDE 1-1/4" PVC SCHEDULE 80 CONDUIT.
PANELBOARD.
RATING SHALL MATCH EXISTING BREAKERS RATING IN
POLE 20 AMP BREAKER IN EXISTING PANELBOARD. AIC
1. EXISTING 200 AMP PANELBOARD. PROVIDE 2 SINGLE
ES101
S
IT
E E
L E
C T
R
IC
A L P
L A
N -A
R E
A A
R E
V
IS
E D I
N A
C C
O R
D A
N C
E W
IT
H A
M E
N D
M E
N T
S
E P
A N
S I
D
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
M
B R
E N
N A
N
SHEET ID
F
IL
E N
A M
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
®of Engineers
US Army Corps
C A
T E
G O
R Y C
O D
E
-7
-0
B S E
S .d g n
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D E
S C
R
IP
T
IO
N
S A
V A
N N
A H D
IS
T R
IC
T F
IE
L D R
E S
E A
R C
H F
A C
IL
IT
Y A
N N
E X
W
O G
L E
T H
O R
P E A
V E
S A
V A
N N
A H
G A
S
B A
R B
IN
A
F Y
P
N
V O
L U
M E S
IT
E
D U
C K
N O
R T
H C
A R
O L
IN
A D
V A
U G
H N
J U
L Y
D
V A
U G
H N
READY TO ADVERTISE (RTA)
W
H N -2
-B -3 k6enxjlh
08-SEP-2020 09:29
IP_PWP:dms27312\BS91397_ES101.dgn
| BS91397_ES101 |
| References |
| Design Model, PW_WORKDIR:dms27312 |
| BS91397_bs.dgn |
| PW_WORKDIR:dms27312 |
| BS91397_ep.dgn |
| BS91397-nt.dgn |
| CFxPN91397-CIVIL-CONST-LIMS.dgn, Model |
| CFxPN91397-CIVIL-SITE.dgn, Model |
| CFxPN91397-CIVIL-UTIL.dgn, Model |
| 3 SCRN20, PW_WORKDIR:dms27296 |
| 100% ERDC CIVIL-SURVEY-MOD.dgn, Model |
| 4 SCRN30, PW_WORKDIR:dms27296 |
| 100% ERDC CIVIL-CONST-LIMS.dgn, Model |
| 5 SCRN30, PW_WORKDIR:dms27296 |
| 100% ERDC CIVIL-UTIL.dgn, Model |
| 6 SCRN30, PW_WORKDIR:dms27312 |
| BS91397_epx.dgn |
| 2 SCRN30, PW_WORKDIR:dms27296 |
| 100% ERDC CIVIL-DEMO.dgn, Model |
| 1 SCRN20, PW_WORKDIR:dms27296 |
| 100% ERDC CIVIL-SITE.dgn, Model |
File details come from the government source that posted it. Updated .