W912HN-20-B-3013_VOL2.pdf
PDF 7 MB Posted
- Attached to
- PN91397 Field Research Facility Annex
- Solicitation number
- W912HN20B3013
About this file
This document provides details for a federal construction contract solicitation. The U.S. Army Corps of Engineers, Savannah District is soliciting bids to construct a 4,008 square foot Field Research Facility Annex in Duck, North Carolina for $1,000,000 to $5,000,000. The project includes offices, administrative support areas, a team room, secure meeting room, support shop space, restroom, janitor closet, telecommunications room, electrical room and mechanical room, as well as building information systems, NIPR and SIPR networks, and a fire detection and alarm system. This is a 100% small business set-aside contract under NAICS code 236220 for commercial and institutional construction. Bids are due by invitation through the Federal Business Opportunities website. The point of contact for questions is Ms. Tonja Dreke of the Savannah District. Award will be made following sealed bid procedures in FAR Part 14.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Bid Opening Log.pdf | ||
| Bid Opening Chat.pdf | ||
| C.04 Abstract_W912HN20B3013 Duck NC FRF Annex.pdf | ||
| W912HN-20-B-3013_VOL2_AMD2.pdf | ||
| W912HN-20-B-3013_VOL1_AMD2.pdf | ||
| 20B3013vol1.pdf | ||
| W912HN20B30130002.pdf | ||
| W912HN20B30130001.pdf | ||
| 20B3013vol2.pdf | ||
| 20B3013vol1.pdf | ||
| FRF Annex Pre-Bid Site Visit.pdf | ||
| 20B3013vol2.pdf | ||
| 20B3013vol3.pdf | ||
| 20B3013vol1.pdf | ||
| W912HN-20-B-3013_VOL1.pdf |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
US Army Corps of Engineers ®
SIGNATURES AFFIXED BELOW INDICATE OFFICIAL RECOMMENTATION
AND APPROVAL OF ALL DRAWINGS IN THIS SET AS INDEXED ON THIS SHEET.
Reviewed by:*
Approval Recommended:*
Approved:*
QUALITY CONTROL/PE/A DATE
DATE
DATE
DESIGN BRANCH, CHIEF
ENGINEERING DIVISION, CHIEF
*THIS PROJECT WAS DESIGNED BY THE U.S. ARMY CORPS OF ENGINEERS,
SAVANNAH DISTRICT. INDIVIDUALS WHOSE SIGNATURES AND REGISTRATION
DESIGNATIONS APPEAR ON THESE DOCUMETNS ARE OPERATING WITHIN THE
SCOPE OF THEIR EMPLOYMENT. SIGNATURES ARE REQUIRED BY ER 1110-1-8152.
CONTRACT NO.:
SOLICITATION NO.:
ISSUE DATE:
C:\Users\k6enxjlh\Desktop\Projects\Bsu0001\04_W912HN-20-B-3013\Revit\FY20PN91397_PROJ_R18_TW Current.rvt22-Jul-20 5:45:56 PM
JU
LY
W
2H N
-2 0-
B-
J.
H
AI
R
E
J.
H
AI
R
E
S.
B
AR
BI
N A
G-001
C O
VE
R
S H
EE
T
D U
C K, N O
R
TH
C
AR
O
LI
N A
FI
EL
D R
ES
EA
R C
H F
AC
IL
IT
Y
AN
N
EX
FY
, P
N
VO
LU
M E
-B
U
IL
D
IN
G
J.
M
C
TI
ER
N
AN
SAVANNAH DISTRICT
W912HN-20-B-3013
JULY 2020
DUCK, NORTH CAROLINA
FIELD RESEARCH FACILITY ANNEX
FY20, PN 91397
0-
-0
SA
VA
N N
AH
D
IS
TR
IC
T
W
ES
T O
G
LE
TH
O
R
PE
A
VE
N U
E
SA
VA
N
N
AH
, G A
READY TO ADVERTISE (RTA)
VOLUME 2 - BUILDING M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
BARBINA.SEAN.ERIC.1556536194 Digitally signed by BARBINA.SEAN.ERIC.1556536194 Date: 2020.07.23 17:25:49 -04'00'
FUNK.TROY.ALAN.1039429256 Digitally signed by FUNK.TROY.ALAN.1039429256 Date: 2020.07.23 23:59:40 -04'00'
HENDREN.TRACY.LEE.1229932868
2020.07.27 09:03:13 -04'00'
A N
S I
D
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
J
H A
IR
E
J
M C
T
IE
R N
A N
S
B A
R B
IN
A
F
IE
L D R
E S
E A
R C
H F
A C
IL
IT
Y A
N N
E X
F Y P
N
SHEET ID
F
IL
E N
A M
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
®of Engineers
US Army Corps k6enxjlh
22-JUL-2020 18:50
C:\Users\k6enxjlh\Desktop\Projects\Bsu0001\04_W912HN-20-B-3013\PDF\Volume 2\GI001V2.dgn
C A
T E
G O
R Y C
O D
E
-7
-0
GI001
IN
D
E X O
F D
R A
W
IN
G S
G I0
V .d g n
D U
C K
N O
R T
H C
A R
O L
IN
A
V O
L U
M E B
U
IL
D
IN
G
J U
L Y
J
H A
IR
E
READY TO ADVERTISE (RTA)
W
H N -2
-B -3
SHEET ID.
INDEX OF DRAWINGS
D E
S C
R
IP
T
IO
N
W
O G
L E
T H
O R
P E A
V E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
S A
V A
N N
A H D
IS
T R
IC
T
S A
V A
N N
A H
G A
SHEET ID.
TITLESHEET ID.
TITLETITLE
G-001 COVER SHEET
GI001 INDEX OF DRAWINGS
GI002 GENERAL NOTES, ABBREVIATIONS
S-001 GENERAL STRUCTURAL NOTES
S-002 GENERAL STRUCTURAL NOTES
S-003 DESIGN DATA
SB101 PILE LAYOUT PLAN
SF100 ELEVATED DECK COMPOSITE PLAN
SF101A ELEVATED DECK PLAN
SF101B INTERIOR SLAB PLAN
SF102 ELEVATED DECK ACCESS PLAN
SF120 ROOF FRAMING PLAN
SF201 FRAMING ELEVATIONS
SF202 FRAMING ELEVATIONS
SF203 FRAMING ELEVATIONS
SF501 ELEVATED DECK DETAILS
SF502 ELEVATED DECK DETAILS
SF503 ELEVATED DECK ACCESS DETAILS
SF504 MASONRY DETAILS
SF505 FRAMING DETAILS
SF506 FRAMING DETAILS
SF507 FRAMING DETAILS
SF508 FRAMING DETAILS
SF509 FRAMING DETAILS
SF601 FRAMING SCHEDULES
A-101 ELEVATED DECK/ BUILDING COMPOSITE PLAN
A-102 FLOOR PLAN
A-103 DIMENSION FLOOR PLAN
A-104 ROOF PLAN
A-105 REFLECTED CEILING PLAN
A-201 NORTH AND SOUTH ELEVATIONS
A-202 EAST AND WEST ELEVATIONS
A-301 BUILDING CROSS SECTION
A-302 BUILDING LONGITUDINAL SECTION
A-310 WALL SECTIONS
A-311 WALL SECTIONS
A-312 WALL SECTIONS
A-400 ENLARGED STAIR & RAMP PLAN
A-401 ENLARGED TOILET/MOTHER'S RM PLANS AND ELEVATIONS
A-402 ENLARGED JANITOR CLOSET AND EYEWASH/SHOWER PLANS AND ELEVATIONS
A-500 ROOF DETAILS
A-510 CEILING DETAILS
A-520 INTERIOR DETAILS
A-530 EXTERIOR DETAILS
A-540 DOOR DETAILS
A-541 DOOR DETAILS
A-550 WINDOW AND LOUVER DETAILS
A-601 PARTITION TYPES
A-602 ROOM FINISH & EXTERIOR COLOR SCHEDULE
A-603 DOOR SCHEDULE AND TYPES
A-604 LOUVER SCHEDULE AND WINDOW AND LOUVER TYPES
A-700 AIR BARRIER BOUNDERY FLOOR PLAN & BUILDING CROSS SECTIONS
A-800 LIFE SAFETY CODE ANALYSIS (FOR REFERENCE ONLY)
A-801 LIFE SAFETY FIRST FLOOR PLAN (FOR REFERENCE ONLY)
A-901 PERSPECTIVE VIEW
I-101 FURNITURE PLAN
I-501 INTERIOR FINISH LEGEND & DETAILS
I-502 SIGNAGE TYPICALS
I-601 ROOM FINISH SCHEDULE
I-602 SIGNAGE SCHEDULE & DETAILS
F-001 FIRE PROTECTION LEGEND AND GENERAL NOTES
FA001 FIRE ALARM LEGEND AND OPERATIONS MATRIX
FA101 FIRE ALARM AND MNS FLOOR PLAN
FA102 FIRE ALARM PLATFORM PLAN
FA601 FIRE ALARM AND MNS DIAGRAMS
P-001 PLUMBING LEGEND
PL101 DOMESTIC PLUMBING FLOOR PLAN
PL102 SANITARY PLUMBING FLOOR PLAN
PL401 PLUMBING ENLARGED PLANS
PL402 PLUMBING ENLARGED PLANS
PL501 PLUMBING DETAILS
PL502 PLUMBING DETAILS
PL503 PLUMBING DETAILS
PL601 PLUMBING SCHEDULES
PL901 DOMESTIC RISER DIAGRAM
PL902 SANITARY RISER DIAGRAM
M-001 HVAC LEGEND
MH101 HVAC FLOOR PLAN
MH301 HVAC SECTIONS
MH401 HVAC ENLARGED PLANS
MH501 HVAC DETAILS
MH502 HVAC DETAILS
MH503 HVAC DETAILS
MH504 HVAC DETAILS
MH601 HVAC SCHEDULES
MH901 MECHANICAL ROOM ISO
MI801 HVAC CONTROLS LEGEND
MI802 HVAC CONTROLS GENERAL NOTES
MI803 AHU-1 CONTROLS
MI804 AHU-2 CONTROLS
MI805 DUCTLESS SPLIT SYSTEM CONTROLS
MI806 UNIT HEATER AND EXHAUST FAN CONTROLS
MI807 THERMOSTATICALLY CONTROLLED EXHAUST FAN CONTROLS
MP101 HVAC HYDRONIC PIPING PLAN
E-001 LEGEND AND NOTES
EL101 LIGHTING PLAN - BUILDING
EL102 LIGHTING PLAN - WALKWAY
EL501 LUMINAIRE SCHEDULE
EL502 LUMINAIRE DETAILS
EL601 LIGHTING CONTROL STRATEGIES & DETAILS
EP101 POWER PLAN
EP102 EQUIPMENT PLAN
EP401 ENLARGED PLANS
EP501 POWER DETAILS
EP502 GENERATOR DETAILS
EP601 POWER ONE-LINE DIAGRAM
EP602 MISC SCHEDULES
EP603 PANEL SCHEDULES
EP604 PANEL SCHEDULES
EP605 PANEL SCHEDULES
EY001 SPECIAL SYSTEMS LEGEND AND NOTES
EY101 SPECIAL SYSTEMS PLAN
EY501 IDS EQUIPMENT DETAILS
EG101 LIGHTNING PROTECTION PLAN
EG501 LIGHTNING PROTECTION DETAILS
EG502 MISC GROUNDING DETAILS
T-001 COMMUNICATIONS LEGEND AND GENERAL NOTES
TN101 COMMUNICATIONS PLAN
TN401 ENLARGED COMMUNICATIONS PLAN
TN501 COMMUNICATIONS DETAILS
TN502 COMMUNCATIONS DETAILS
TN601 COMMUNICATIONS DIAGRAMS
SHEET LOGICMATERIALS
EARTH
DRAWING ABBREVIATIONS GENERAL NOTES
C (cont) ---------------------
CORR CORRIDOR
CP CONCRETE PIPE
CPT CARPET
CR CONTROL ROOM
CS CAST STONE
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CU FT CUBIC FEET
CW CASEMENT WINDOW
D ---------------------
D DEPTH
D LABEL CLASS D DOOR
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
E ---------------------
E LABEL CLASS E DOOR
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION
AND FINISH SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
ENTR ENTRANCE
EPS EXPANDED POLYSTYRENE
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXP EXPOSED, EXPANSION
EXT EXTERIOR, EXTINGUISHER
EXT GR EXTERIOR GRADE
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR
PANEL
FAS BD FASCIA BOARD
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FED FEDERAL
FF FINISH FLOOR
FFE FINISH FLOOR ELEVATION
FF INSUL FOIL BACKED INSULATION
FGL FIBERGLASS
FH FIRE HOSE
FHP FULL HEIGHT PARTITION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FM FACTORY MUTUAL
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FRG FIBER REINFORCED GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED
PLASTIC
FRTW FIRE RETARDANT TREATED
WOOD
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET
FTG FOOTING
FWC FABRIC WALLCOVERING
G ---------------------
G NATURAL GAS
GALV GALVANIZED
GB GRAB BAR
GEJ GUTTER EXPANSION JOINT
G (cont) ---------------------
GFCI GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
GFGI GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
GFRG GLASS-FIBER-REINFORCED
GYPSUM
GLZ GLAZING
GR FL GROUND FLOOR
GUT GUTTER
GWB GYPSUM WALL BOARD
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H ---------------------
HB HOSE BIBB
HC HANDICAPPED
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE
AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING
CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J ---------------------
JAN JANITOR
JT JOINT
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBR LUMBER
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LG LIGHT GAUGE
LIB LIBRARY
LIN LINEAR
LKR LOCKER
LOC LOCATION
LT LIGHT
LVDR LOUVER DOOR
LVR LOUVER
M ---------------------
MACH RM MACHINE ROOM
MATL MATERIAL
MAX MAXIMUM
MC MOISTURE CONTENT
MD METAL DECK
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MEMB MEMBRANE
MF MILL FINISH
MFR MANUFACTURER
MID MIDDLE
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MO MASONRY OPENING
MOD MODIFY
MB MOISTURE BARRIER
MTD MOUNTED
MTG MOUNTING
MTL METAL
MVBL MOVABLE
MWP MEMBRANE WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
N (cont) ---------------------
NOM NOMINAL
NP NO PAINT
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPQ OPAQUE
OWSJ OPEN WEB STEEL JOIST
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PAR PARAPET
PAT PATTERN
PB PULL BOX
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PIL PILASTER
PL PROPERTY LINE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLG PILING
PLYWD PLYWOOD
PNL PANEL
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PREFIN PREFINISHED
PRKG PARKING
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER
AND RECEPTACLE
PTN PARTITION
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDG INS RIGID INSULATION, SOLID
REC RECESSED
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RL ROOF LEADER
RLG RAILING
RM ROOM
RO ROUGH OPENING
RSD ROLLING STEEL DOOR
RV ROOF VENT
RVL REVEAL
S --------------------
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
S (cont) --------------------
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGL SINGLE
SHT MTL SHEET METAL
FLASH (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SKLT SKYLIGHT
SLNT SEALANT
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS STAINLESS STEEL
SSMR STANDING SEAM METAL ROOF
ST STAIRS
STC SOUND TRANSMISSION
COEFFICIENT
STD STANDARD
STL STEEL
STL JST STEEL JOIST
STL RF DK STEEL ROOF DECK
STOR STORAGE
STR STRINGERS
STRB/HRN STROBE/HORN
STRUC STRUCTURAL
SUB FL SUBFLOOR
SUSP SUSPENDED
SV SHEET VINYL
SW SIDEWALK
T --------------------
T TREAD
T/S TUB/SHOWER
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TFF TOP OF FINISH FLOOR
TH THICK
THK THICKNESS
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TRANS TRANSOM
TRTD TREATED
TV TELEVISION
TYP TYPICAL
U --------------------
UG UNDERGROUND
UH UNIT HEATER
UL UNDERWRITER
LABORATORIES
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER
SYSTEM
V --------------------
VAV VARIABLE AIR VOLUME/UNIT
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VTR VENT THRU ROOF
W --------------------
W/ WITH
WC WATER CLOSET
WD WOOD
WDW WINDOW
W/O WITHOUT
WWF WELDED WIRE FABRIC
X --------------------
XFMR TRANSFORMER
A ---------------------
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ABV ABOVE
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL SYSTEM
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH
DIDISABILITIES ACT
ADJ ADJACENT
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVG AVERAGE
AWT ACOUSTICAL WALL TREATMENT
B ---------------------
B LABEL CLASS B DOOR
BALC BALCONY
BD BOARD
BDRY BOUNDARY
BEJ BRICK EXPANSION JOINT
BFF BELOW FINISH FLOOR
BHMA BUILDER'S HARDWARE
MANUFACTURER'S
ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BRG BEARING
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
C LABEL CLASS C DOOR
CAB CABINET
CATW CATWALK
CAV CAVITY
CBB CEMENTITIOUS (BACKER)
BOARD
CD CONSTRUCTION DOCUMENTS
CDW CHILLED DRINKING WATER
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CFCI CONTRACTOR FURNISHED/
CONTRACTOR INSTALLED
CFE CONTRACTOR FURNISHED
EQUIPMENT
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR COLOR
CMU CONCRETE MASONRY UNIT
CNDS CONDENSATE
CDR CARD READER
CO CLEANOUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
CONT CONTINUE, CONTINUOUS
COORD COORDINATE
0 GRID/COLUMN
LINE DESIGNATOR
INTERIOR ELEVATION
SECTION
ROOM
NAME/NUMBER
REVISION
TAG
PLAN, BLOW-UP
DETAIL
PLAN NORTH
NORTH ARROW
W/ TRUE NORTH
INDICATION
SPOT ELEVATION
Name Elevation REFERENCE LEVEL
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
A-101
SIM
EXTERIOR ELEVATION
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
A-101
SYMBOLS
INTERIOR ELEVATION SYMBOL
EXTERIOR ELEVATION SYMBOL
SECTION SYMBOL
CALLOUT SYMBOL
ELEVATION SYMBOL
LEVEL SYMBOL
GENERAL SYMBOLS
Room name
Room name
150 SF
ROOM
NAME/NUMBER
W/ AREA
CENTERLINE
INDICATOR
1/2 1 21
SCALE: 1"=1'-0"
SCALE BAR
View Name1
MATCHLINE INDICATOR
VIEW TITLE BAR
1 / A-101
1 / A-102
REFERENCE
SHEETS
SAND
CONCRETE/ PRECAST
CONCRETE
STONE
BRICK
CMU
PLYWOOD
RIGID INSULATION
BATT INSULATION
GYPSUM BOARD,
PLASTER
EIFS
1. THESE LEGENDS ARE COMPOSED OF STANDARD SYMBOLS AND ARE PERTINENT TO THE CONDITIONS
ON THIS SET OF DRAWINGS TO THE EXTENT APPLICABLE.
2. ADDITIONAL LEGENDS AND/OR ABBREVIATIONS MAY APPEAR IN THIS SET OF DRAWINGS TO INDICATE
SPECIFIC CONDITIONS IN LIEU OF SYMBOLS SHOWN ON THIS SHEET.
A-101
SIM
A101
Ref
R ef
Ref
R ef
AE201
DISCIPLINE*:
G - GENERAL
C - CIVIL
L - LANDSCAPE
S - STRUCTURAL
A - ARCHITECTURE
DISCIPLINE DESIGNATOR
SHEET TYPE
DESIGNATOR
SHEET SEQUENCE
NUMBER
F- FIRE PROTECTION
P - PLUMBING
M - MECHANICAL
E - ELECTRICAL
T-
TELECOMMUNICATIONS
*ADDITIONAL DISCIPLINES MAY BE USED
IN THIS DRAWING SET.
DRAWING NAMING CONVENTION
SHEET ID
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6enxjlh\Desktop\Projects\Bsu0001\04_W912HN-20-B-3013\Revit\FY20PN91397_PROJ_R18_TW Current.rvt22-Jul-20 5:46:12 PM
JU
LY
W
2H N
-2 0-
B-
J.
H
AI
R
E
J.
H
AI
R
E
S.
B
AR
BI
N A
0-
-0
GI002
G
EN
ER
AL
N O
TE
S, A
BB
R
EV
IA
TI
O N
S
SA
VA
N N
AH
D
IS
TR
IC
T
W
ES
T O
G
LE
TH
O
R
PE
A
VE
N U
E
SA
VA
N
N
AH
, G A
D U
C K, N O
R
TH
C
AR
O
LI
N A
FI
EL
D R
ES
EA
R C
H F
AC
IL
IT
Y
AN
N
EX
FY
, P
N
VO
LU
M E
-B
U
IL
D
IN
G
J.
M
C
TI
ER
N
AN
READY TO ADVERTISE (RTA)
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
GENERAL NOTES:
G-1. THIS STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER ALL BUILDING CONSTRUCTION IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION
PROCEDURES AND SEQUENCES TO ENSURE SAFETY OF THE BUILDING AND ITS COMPONENTS
DURING ERECTION. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING,
TEMPORARY BRACING, GUYS, OR TIE-DOWNS.
G-2. THE CONTRACT DOCUMENTS DO NOT INDICATE THE MEANS AND METHODS OF CONSTRUCTION. THE
CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK DURING ERECTION AND CONSTRUCTION
AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, PROCEDURES,
TECHNIQUES, SEQUENCES, LOADINGS AND SAFETY.
G-3. USE STRUCTURAL DRAWINGS IN CONJUNCTION WITH ALL OTHER DRAWINGS AND SPECIFICATIONS.
COORDINATE THE WORK OF OTHER TRADES INCLUDING, BUT NOT LIMITED TO, THE REQUIREMENTS
FOR SLEEVES, INSERTS, HOLES, HANGERS, AND ANCHORS.
G-4. REPORT DISCREPANCIES IN DIMENSIONS BETWEEN DIFFERENT DRAWINGS TO THE CONTRACTING
OFFICER PRIOR TO BEGINNING WORK IN IMPACTED AREAS.
G-5. DETAILS TITLED OR NOTED AS "TYPICAL" APPLY NOT ONLY WHERE SPECIFICALLY INDICATED OR
REFERENCED, BUT ALSO IN ALL OTHER CASES WHERE THE NATURE OF THE CONSTRUCTION
REQUIRES THEIR USE. DETERMINE APPLICABILITY OF TYPICAL DETAILS FROM DESCRIPTIVE TITLES OR FROM THE SIMILARITY OF A CONSTRUCTION CONDITION TO ANOTHER CONDITION WHERE THE
DETAIL IS SPECIFICALLY INDICATED OR REFERENCED.
G-6. ELEVATIONS ON THE STRUCTURAL DRAWINGS ARE DENOTED AS [±X'-X"] REFERENCED TO THE INTERIOR
FLOOR ELEVATION DATUM [0'-0"]. SEE CIVIL DRAWINGS FOR ACTUAL DATUM ELEVATION.
G-7. REPRODUCTION OF CONTRACT DRAWINGS SHALL NOT BE USED AS SHOP DRAWINGS UNDER ANY
CIRCUMSTANCE.
SHALLOW FOUNDATION NOTES:
F-1. SHALLOW FOUNDATIONS HAVE BEEN DESIGNED TO BEAR ON SOIL CAPABLE OF SUPPORTING AN
ALLOWABLE BEARING PRESSURE OF 1500 PSF AS STATED IN THE GEOTECHNICAL REPORT
REFERENCED ABOVE.
F-2. ALL FOUNDATION EXCAVATIONS SHALL BE INSPECTED AND APPROVED BY THE CONTRACTOR'S
PROFESSIONAL GEOTECHNICAL ENGINEER PRIOR TO PLACING CONCRETE.
F-3. ALL EXCAVATIONS SHALL BE PERFORMED SO THAT THE SITE AND THE AREA IMMEDIATELY SURROUNDING THE SITE WHICH AFFECTS CONSTRUCTION OPERATIONS WILL BE CONTINUALLY AND
EFFECTIVELY DRAINED. THE CONTRACTOR SHALL PROVIDE DRAINAGE AND DEWATERING AS
REQUIRED TO ENSURE THAT ALL FOOTING EXCAVATIONS ARE ACCOMPLISHED WITH THE SUBGRADE SOILS REMAINING DRY AND FIRM UNTIL AFTER FOOTINGS ARE PLACED AND BACKFILLED. REMOVAL OF
SURFACE WATER, GROUNDWATER, AND ANY PERCHED WATER CONDITIONS WHICH MIGHT BE
ENCOUNTERED DURING EXCAVATIONS, SHALL BE ACCOMPLISHED BY APPROVED MEANS. REFER TO SPECIFICATION SECTION 31 00 00, EARTHWORK, AND TO SHEET B-301 FOR ADDITIONAL EXCAVATION
REQUIREMENTS.
F-4. DO NOT PLACE FOUNDATION CONCRETE ON FROZEN OR SATURATED SUBGRADES.
F-5. ENSURE THAT EARTH-FORMED FOOTINGS CONFORM TO THE SHAPE, LINES, AND THICKNESSES INDICATED ON THE FOUNDATION PLAN, SECTIONS, AND FOOTING SCHEDULES. EXCAVATION WIDTHS
SHALL BE A MINIMUM OF 4" GREATER THAN DIMENSIONS INDICATED.
F-6. DO NOT INSTALL FOUNDATIONS UNTIL FOUNDATION WORK HAS BEEN COORDINATED WITH ADJACENT
UNDERGROUND UTILITIES.
CONCRETE CONSTRUCTION NOTES:
C-1. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF THE "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318-14) AND THE SPECIFICATIONS FOR
STRUCTURAL CONCRETE (ACI 301-14) OF THE AMERICAN CONCRETE INSTITUTE (ACI).
C-2. CONCRETE SHALL MEET THE DURABILITY REQUIREMENTS OF ACI 318-14 FOR THE EXPOSURE CLASS LISTED, NOT LIMITED TO THE W/C MAX AND 28 DAY MIN f'C LISTED:
COMPONENT EXPOSURE W/C MAX MIN f'C (PSI)
PRECAST PILES F2 S0 W1 C2 0.40 5000
BEAMS F2 S0 W0 C2 0.40 5000
ELEVATED SLAB F2 S0 W0 C2 0.40 5000
STAIRS/RAMP F2 S0 W0 C2 0.40 5000
INT. TOPPING SLAB F0 S0 W0 C0 N/A 3000
C-3. CONCRETE DENSITY SHALL BE NORMAL WEIGHT WITH A DENSITY OF 140 PCF TO 150 PCF UNLESS
NOTED OTHERWISE ON PLANS.
C-4. CONCRETE REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A615/A615M, GRADE 60 AND SHALL HAVE FABRICATION TOLERANCES IN ACCORDANCE WITH ACI 315. SHOP
FABRICATE REINFORCING BARS WHICH ARE INDICATED TO BE BENT OR HOOKED.
C-5. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 OR ASTM A497. PROVIDE SHEET-TYPE WELDED
WIRE FABRIC. SHEET LAPS SHALL BE TIED AND LAPPED ONE FULL MESH SPACING PLUS 2".
C-6. CONCRETE REINFORCING STEEL SHALL BE CONTINUOUS UNLESS OTHERWISE INDICATED. CONTINUOUS
REINFORCING STEEL SHALL BE SPLICED AS SHOWN IN SCHEDULE ON SF601 UNO ON PLANS.
REINFORCING STEEL SHALL BE PLACED SO THAT SPACING IS GREATER THAN OR EQUAL TO 2X BAR
DIAMETER.
C-7. MINIMUM CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS INDICATED. IN NO CASE SHALL
REINFORCEMENT COVER BE LESS THAN THE REQUIREMENTS OF ACI 301.
A. CONCRETE DEPOSITED AGAINST THE GROUND 3"
B. CONCRETE EXPOSED TO EARTH OR WEATHER 2"
C-8. CONCRETE REINFORCING STEEL MARKED STANDARD HOOK SHALL HAVE A 90° HOOK A MINIMUM OF 12 BAR DIAMETERS IN LENGTH, UNLESS OTHERWISE NOTED. STIRRUPS, TIES, AND 180° HOOKS SHALL
CONFORM TO THE REQUIREMENTS OF ACI 318.
C-9. PROVIDE 1/2" THICK PRE-MOLDED JOINT FILLER MATERIAL WHERE SLABS ON GRADE ABUT VERTICAL
SURFACES.
C-10. ALL EMBEDDED ITEMS SHALL BE PROPERLY PLACED, ACCURATELY POSITIONED AND MAINTAINED
SECURELY IN PLACE PRIOR TO AND DURING CONCRETE PLACEMENT.
DESIGN CODE NOTES:
D-1. STRUCTURAL DESIGN IS IN ACCORDANCE WITH THE FOLLOWING CODES AND
SPECIFICATIONS:
A. IBC 2018, INTERNATIONAL BUILDING CODE
B. ASCE 7-16, MINIMUM DESIGN LOADS FOR BUILDINGS AND STRUCTURES
C. ASCE 24-14, FLOOD RESISTANT DESIGN AND CONSTRUCTION
D. ACI 318-14, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
E. ACI 350-06, CODE REQUIREMENTS FOR ENVIRONMENTAL ENGINEERING AND
CONCRETE STRUCTURES
F. TMS 402/602-16, BUILDING CODE REQUIREMENTS AND SPECIFICATION FOR MASONRY
STRUCTURES
G. AISC 360-16, SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS
H. AISI S100-16, NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD FORMED
STEEL STRUCTURAL MEMBERS.
I. SDI, STEEL DECK INSTITUTE: DESIGN MANUAL FOR COMPOSITE DECK, FORM DECK, &
ROOF DECK
J. UFC 1-200-01, DOD BUILDING CODE, (8 OCT 2019)
K. UFC 3-301-01, STRUCTURAL ENGINEERING, (1 OCT 2019)
L. UFC 4-010-01, DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, (12 DEC 2018)
DESIGN LOAD CRITERIA:
D-2. ELEVATED PLATFORM LIVE LOADS:
STAIRS 100 PSF (UNREDUCIBLE)
ELEVATED PLATFORM 150 PSF (UNREDUCIBLE)
D-3. ROOF LIVE LOAD: 20 PSF (REDUCIBLE)
D-4. SNOW LOADS:
RISK CATEGORY II
SNOW IMPORTANCE FACTOR, Is 1.0 MINIMUM GROUND SNOW LOAD, Pg 10 PSF
FROST PENETRATION DEPTH 0 IN
BALANCED SNOW LOADING:
MINIMUM LOW SLOPE ROOF SNOW LOAD, Pm 10 PSF
UNBALANCED SNOW LOADING:
SEE S-003
SNOW DRIFT LOADING: (ROOF HEADWALLS)
SEE S-003
D-5. WIND LOADS:
RISK CATEGORY II
WIND IMPORTANCE FACTOR, Iw 1.0
BASIC WIND SPEED, V 132 MPH (ULTIMATE)
102 MPH (SERVICE)
WIND EXPOSURE CATEGORY D
GUST EFFECT FACTOR, G 0.85
INTERNAL PRESSURE COEFFICIENTS, GCpi +/- 0.18
D-6. SEISMIC LOADS:
RISK CATEGORY II
SEISMIC IMPORTANCE FACTOR, Ie 1.0 MAPPED SPECTRAL RESPONSE ACCELERATION, Ss 0.068
MAPPED SPECTRAL RESPONSE ACCELERATION, S1 0.037
SITE CLASS D (ASSUMED)
DESIGN SPECTRAL RESPONSE ACCELERATION, Sds 0.073 DESIGN SPECTRAL RESPONSE ACCELERATION, Sd1 0.059
SEISMIC DESIGN CATEGORY A
PREDICATED ON ASSIGNMENT TO SEISMIC DESIGN CATEGORY A, STRUCTURAL AND
NONSTRUCTURAL COMPONENTS ARE EXEMPT FROM SEISMIC DESIGN REQUIREMENTS.
(ASCE 7-16, SECTION 11.7)
D-7. FLOOD LOADS:
COASTAL ZONE VE
BASE FLOOD ELEVATION, BFE 12 FT
DESIGN FLOOD ELEVATION, DFE 13 FT
D-8. ANTI-TERRORISM/FORCE PROTECTION CRITERIA:
NEW BUILDING LOCATION WITHIN A CONTROLLED PERIMETER
BUILDING CATEGORY INHABITED BUILDING
DESIGN LEVEL OF PROTECTION (LOP) LOW (VLOP)
PROGRESSIVE COLLAPSE CRITERIA APPLIES NO (<3 STORIES)
SPECIAL INSPECTION NOTES:
SI-1. INSPECTION OF FABRICATORS SHALL BE CONDUCTED IN ACCORDANCE WITH
IBC 2018, SECTION 1704.2.5.
SI-2. INSPECTION OF STEEL CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE
WITH IBC 2018, SECTION 1705.2.
SI-3. INSPECTION OF CONCRETE CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE
WITH IBC 2018, SECTION 1705.3 AND TABLE 1705.3.
SI-4 INSPECTION OF MASONRY CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE
WITH IBC 2018, SECTION 1705.4.
SI-5. INCLUDE SPECIAL INSPECTIONS REQUIREMENTS IN CONTRACTOR'S QUALITY
CONTROL (CQC) PLAN.
SI-6. THE CONTRACTOR SHALL RETAIN THIRD PARTY QUALITY ASSURANCE AGENCIES
TO CONDUCT SPECIAL INSPECTIONS REQUIRED BY IBC. INSPECTING AGENCY
SHALL PROVIDE REPORTS OF SPECIAL INSPECTIONS DIRECTLY TO THE GOVERNMENT.
PRESTRESSED CONCRETE PILE NOTES:
P-1. FOUNDATIONS FOR THIS PROJECT HAVE BEEN PLANNED IN ACCORDANCE WITH THE
RECOMMENDATIONS IN THE GEOTECHNICAL REPORT PREPARED BY THE SAVANNAH DISTRICT TITLED
"SUBSURFACE EXPLORATION AND GEOTECHNICAL ENGINEERING REPORT, ERDC FIELD RESEARCH
FACILITY ANNEX, FY 20, PN 91397, BASE SUPPORT UNIT ELIZABETH CITY, NC", DATED MARCH 2020.
P-2. THE COMPLETE DESIGN AND DETAILING OF THE PRESTRESSED CONCRETE PILES IS THE SOLE RESPONSIBLITY OF THE CONTRACTOR'S PRESTRESSED CONCRETE PILE MANUFACTURER. PILE DESIGN CALCULATIONS SHALL BE SUBMITTED WITH THE PILE SHOP DRAWINGS. CALCULATIONS SHALL BE SIGNED AND SEALED BY A PROFESSIONAL ENGINEER EXPERIENCED IN THE DESIGN OF PRESTRESSED
CONCRETE PILES.
P-3. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS (f'c) OF 5,000 PSI AND SHALL
BE AIR-ENTRAINED 4.5 TO 7.5 PERCENT.
P-4. MAXIMUM WATER-CEMENT RATIO SHALL BE 0.40 . CEMENT SHALL CONFORM TO ASTM C150, TYPE II OR
III MODIFIED AND SHALL HAVE A MAXIMUM TRICALCIUM ALUMINATE CONTENT OF 8 PERCENT.
P-5. MAXIMUM AGGREGATE SIZE SHALL NOT EXCEED 1 INCH.
P-6. STEEL STRAND FOR PILES SHALL CONFORM TO ASTM A416, GRADE 270, LOW-RELAXATION TYPE.
P-7. WIRE SPIRAL TIES SHALL BE W3.5 COLD-DRAWN STEEL WIRE CONFORMING TO ASTM A1064.
P-8. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT TIME OF RELEASE OF STRANDS
EQUAL TO 3,500 PSI.
P-9. ALL EXPOSED EDGES SHALL BE CHAMFERED 3/4 INCH MINIMUM.
P-10. ONLY PICK-UP POINTS SHALL BE USED FOR HANDLING AND SUPPORT DURING STORAGE. PICK-UP
POINTS SHALL BE PLAINLY MARKED ON PILES.
P-11. PICK-UP LENGTHS SHALL BE DETERMINED FROM IMPACT LOADS AND BE BASED ON CONCRETE COMPRESSIVE STRENGTH OF 5,000 PSI. IF PILES ARE HANDLED WHEN CONCRETE IS LESS THAN
5,000 PSI, PICK-UP LENGTHS SHALL BE REDUCED ACCORDINGLY.
P-12. IN LIEU OF THE REINFORCING BARS PROJECTING FROM THE PILE HEAD, THE FOLLOWING MAY BE
PROVIDED:
1-3/8" DIA PREFORMED PLAIN HOLES OR 2" DIA HOLES FORMED WITH GALVANIZED
CORRUGATED METAL MAY BE USED. AFTER DRIVING THE PILE AND CLEANING OUT
THE HOLES, REINFORCING BARS SHALL BE INSTALLED AND THE HOLES SHALL BE
FILLED WITH APPROVED HIGH STRENGTH NON-SHRINK GROUT.
P-13. SAFE DESIGN CAPACITY OF EACH PILE IS 80 TONS PER PILE. SERVICE LEVEL BEARING CAPACITY OF EACH PILE IS 40 TONS (SERVICE DEAD LOAD PLUS LIVE LOAD) AND 50 TONS PER PILE (SERVICE DEAD
LOAD PLUS LIVE LOAD PLUS DOWNDRAG LOAD).
P-14. ALLOWABLE DRIFT OF THE PILE IS 0.25 INCHES WITH A PINNED, FREE HEAD CONDITION ASSUMED AT THE TOP OF THE PILE. LATERAL SERVICE LEVEL WIND FORCE IS 1.0 KIP, APPLIED AT THE TOP OF THE
PILE.
P-15. TOLERANCE FOR DRIVING PILES SHALL BE AS SPECIFIED.
P-16. BID LENGTH FOR ALL PILES IS SHALL BE 45 FEET.
P-17. PROVIDE TEST PILES 5 FEET LONGER IN LENGTH THAN PRODUCTION PILES. THE ADDITIONAL TEST PILE LENGTH SHALL BE DRIVEN ONLY AT THE DIRECTION OF THE CONTRACTING OFFICER. PILE LOAD
CAPACITY SHALL BE DETERMINED USING DYNAMIC PILE TESTING.
CONCRETE CONSTRUCTION NOTES:
C-11. REINFORCING STEEL SHALL BE SPREAD AT SLEEVES, ANCHORS, RECESSES AND OTHER EMBEDDED
ITEMS UNLESS OTHERWISE INDICATED. REINFORCEMENT SHALL NOT BE CUT TO FACILITATE
PLACEMENT OF EMBEDDED ITEMS, UNLESS INDICATED.
C-12. NO CONCRETE SHALL BE PLACED UNTIL THE OWNER OR THE CONTRACTING OFFICER'S DESIGNATED
REPRESENTATIVE HAS INSPECTED ALL EMBEDDED WORK, INCLUDING REINFORCEMENT.
C-13. ALL EXPOSED CONCRETE EDGES SHALL BE CHAMFERED 3/4" OR AS INDICATED.
C-14. ALUMINUM SHALL NOT BE PLACED IN DIRECT CONTACT WITH CONCRETE UNLESS EFFECTIVELY COATED
OR COVERED TO PREVENT ALUMINUM-CONCRETE REACTION AND ELECTROLYTIC ACTION BETWEEN
ALUMINUM AND STEEL.
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXCTA\Desktop\Tele-Work Revit Projects\Bsu001 (PN91397)\FY20PN91397_STRUC_R18_TW Current.rvt7/22/2020 8:56:30 AM
JU
LY
W
2H N
-2 0-
B-
C . A
TK
IN
S
C . A
TK
IN
S
S.
B
AR
BI
N A
0-
-0
S-001
G
EN
ER
AL
S
TR
U C
TU
R
AL
N
O
TE
S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
D U
C K, N O
R
TH
C
AR
O
LI
N A
FI
EL
D R
ES
EA
R C
H F
AC
IL
IT
Y
AN
N
EX
FY
, P
N
VO
LU
M E
-B
U
IL
D
IN
G
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
M
AR
K D
ES
C
R
IP
TI
O
N D
STRUCTURAL ABBREVIATIONS
SYMBOL DESCRIPTION
AFF ABOVE FINISHED FLOOR
APPROX APPROXIMATELY
ARCH ARCHITECTURAL
BOC BOTTOM OF CONCRETE
BOF BOTTOM OF FOOTING
BOM BOTTOM OF MASONRY
BOS BOTTOM OF STEEL
BOT BOTTOM
BRG BEARING
BTWN BETWEEN
CJ CONSTRUCTION JOINT
CL CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONN CONNECTION
CONC CONCRETE
CONT CONTINUOUS
CONSTR CONSTRUCTION
DCJ DOWELED CONSTRUCTION JOINT
DEG DEGREE
DIA DIAMETER
DN DOWN
DWG(S) DRAWING(S)
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
EOS EDGE OF SLAB
ES EACH SIDE
EQ EQUAL
EW EACH WAY
FF FINISHED FLOOR
FTG FOOTING
GA GAUGE
GALV GALVANIZED
GOVT GOVERNMENT
HORIZ HORIZONTAL
IJ ISOLATION JOINT
KIP (k) 1000 POUNDS
LG LONG
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
MAX MAXIMUM
MB METAL BUILDING
MBF METAL BUILDING MANUFACTURER
MCJ MASONRY CONTROL JOINT
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL, PLUMBING
MFR MANUFACTURER
MIN MINIMUM
NTS NOT TO SCALE
OC ON CENTER
OPP OPPOSITE
PJF PREMOLDED JOINT FILLER
PL PLATE
PLF POUNDS PER LINEAR FOOT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
RAD RADIUS
REINF REINFORCEMENT
REQD REQUIRED
SCHED SCHEDULE
SE SLAB EDGE
SJ SAWED CONTRACTION JOINT
SJI STEEL JOIST INSTITUTE
SIM SIMILAR
SL SLOPE(D)
SOG SLAB ON GRADE
SPCG SPACING
STD STANDARD
T&B TOP AND BOTTOM
TO TOP OF
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOS TOP OF STEEL
TS THICKENED SLAB
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
WP WORKING POINT
WWF WELDED WIRE FABRIC
STRUCTURAL LEGEND
SLOPE DIRECTION
INDICATES ELEVATION REFERENCED
TO FINISHED FLOOR
KEYED PLAN NOTE
COLUMN REFERENCE LINE
(CENTER LINE OF COLUMN)
SPOT ELEVATION
SLAB DEPRESSION
BRICK WALL
CONCRETE ELEMENT
EARTH FILL
GROUT
CONCRETE MASONRY UNIT (CMU)
POROUS FILL
WELDED WIRE FABRIC (WWF)
STEEL FRAMING REFERENCE
WXxXX
DN
X
[+/- X’-X”]
X
[+/- X’-X”]
AISC SHAPE
DESIGNATION
HSSXxX AISC COLUMN
DESIGNATION
STEEL COLUMN
BF#X
BRACED/MOMENT
FRAME NUMBER
BRACED FRAME
DESIGNATION
MOMENT FRAME
DESIGNATION
STEEL JOIST NOTES:
SJ-1. DESIGN, FABRICATION AND ERECTION OF JOISTS, JOIST EXTENSIONS AND JOIST
SUBSTITUTES SHALL BE IN ACCORDANCE WITH SJI SPECIFICATIONS.
SJ-2. ALL ROOF JOISTS, JOIST EXTENSIONS AND JOIST SUBSTITUTES SHALL BE DESIGNED BY THE
STEEL JOIST FABRICATOR FOR THE DESIGN LOADS NOTED ON THE DRAWINGS INCLUDING:
1. ROOF COLLATERAL DEAD LOAD OF 15 PSF
ROOF COLLATERAL DEAD LOAD OF 7 PSF FOR UPLIFT CALCULATIONS
2. ROOF LIVE LOAD OF 20 PSF WITH LIVE LOAD DEFLECTION LESS THAN L/360.
MAXIMUM DEFLECTION FOR D+L = L/360.
3. NET UPLIFT PRESSURES, GROSS UPLIFT PRESSURES INDICATED ON S-003.
4. POSITIVE WIND PRESSURES INDICATED ON S-003.
5. JOISTS SHALL BE DESIGNED FOR LOAD COMBINATIONS REQUIRED BY IBC, ASCE,
AND UFC.
SJ-3. JOISTS, JOIST EXTENSIONS AND JOIST SUBSTITUTES SHALL BE DESIGNED TO THE
INDICATED SLOPES AND FOLLOWING CRITERIA. ROOF JOISTS SIZES SHOWN ON DRAWINGS
ARE PROVIDED FOR ESTIMATING PURPOSES, HOWEVER SHALL BE MINIMUM REQUIRED AND
ANY CHANGE REQUIRED SHALL BE SUBJECT TO CONTRACTING OFFICER APPROVAL.
SJ-4. JOIST DESIGN SHALL INCLUDE ALL REQUIRED JOIST BRIDGING. BRIDGING SHALL BE SIZED, SPACED, AND INSTALLED IN ACCORDANCE WITH SJI SPECIFICATIONS.
SJ-5. PROVIDE TOP AND BOTTOM CHORD EXTENSIONS WHERE NOTED ON DRAWINGS.
SJ-6. DO NOT CAMBER JOISTS.
SJ-7. CALCULATIONS AND DRAWINGS PREPARED AND SIGNED BY A REGISTERED ENGINEER
SHALL BE SUBMITTED TO THE ENGINEER OF RECORD FOR REVIEW PRIOR TO FABRICATION
OF JOISTS.
SJ-8. JOISTS SHALL BE CONNECTED TO THE SUPPORTING STEEL IN ACCORDANCE WITH SJI
SPECIFICATIONS AND PROJECT CRITERIA NOTED ON DRAWINGS.
SJ-9. SWAY (DIAGONAL BRACING FRO SUSPENDED MECHANICAL EQUIPMENT SHALL ATTACH TO
THE TOP CHORD OF THE JOISTS AND NOT THE BOTTOM CHORD.
STEEL DECK NOTES:
SD-1. ROOF DECK SHALL BE GALVANIZED STEEL CONFORMING TO ASTM A653 WITH A MINIMUM
YIELD STRENGTH OF 33 KSI. STEEL ROOF DECK SHALL BE AS SHOWN ON DRAWINGS.
FASTENERS FOR ROOF DECK SHALL UTILIZE 5/8" DIA PUDDLE WELDS AT A 36/4 PATTERN TO
SUPPORT STRUCTURE AND A MINIMUM OF (4) #10 SELF TAPPING SCREWS AT SIDE LAP
CONNECTIONS.
SD-2. PROVIDE ALL RIDGE PLATES, VALLEY PLATES, CLOSURE PLATES, POUR STOPS, AND ALL
OTHER ACCESSORIES REQUIRED FOR COMPLETE INSTALLATION IN ACCORDANCE WITH THE
DECK MANUFACTURER'S RECOMMENDATIONS.
SD-3. CONTRACTOR SHALL COORDINATE OPENINGS IN STEEL DECK WITH ARCHITECTURAL,
MECHANICAL, AND ELECTRICAL DRAWINGS PRIOR TO DECK PLACEMENT.
SD-4. HANGING LOADS DIRECTLY FROM ROOF DECK IS PROHIBITED.
SD-5. STEEL DECK SHALL SPAN CONTINUOUSLY OVER A MINIMUM OF 4 SUPPORTS (3 SPANS) UNO.
STEEL CONSTRUCTION NOTES:
S-1. FABRICATION AND ERECTION OF STRUCTURAL STEEL AND DESIGN OF CONNECTIONS SHALL BE IN
ACCORDANCE WITH AISC 360-16, "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" AND
AISC 303-16, "CODE OF STANDARD PRACTICE FOR BUILDING AND BRIDGES". THE STRUCTURAL STEEL MEMBERS SHOWN IN THESE DRAWINGS HAVE BEEN ANALYZED AND DESIGNED USING AISC 360-16, LRFD METHOD.
S-2. UNLESS OTHERWISE NOTED, STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH THE ABOVE-
LISTED AISC SPECIFICATION AND THE FOLLOWING:
A. WIDE FLANGE SHAPES (50 KSI) ASTM A992
B. HSS HOLLOW SHAPES (46 KSI) ASTM A500, GRADE B
B. PLATES AND ANGLES ASTM A36
C. HIGH STRENGTH BOLTS ASTM F3125
D. ANCHOR RODS W/ NUT AND WASHER ASTM F1554, GRADE 36
S-3. "ORDINARY CONCENTRICALLY BRACED FRAMES" ARE USED IN THE LATERAL FORCE RESISTING
SYSTEM.
S-4. ALL SHOP AND FIELD WELDING SHALL BE BY CERTIFIED WELDERS AND SHALL CONFORM TO AWS
STANDARDS. USE E70XX ELECTRODES UNLESS OTHERWISE NOTED. MINIMUM WELD SIZE FOR
STRUCTURAL STEEL IS 3/16 IN FILLET, UNLESS OTHERWISE NOTED. CURRENT AWS CERTIFICATIONS
SHALL BE AVAILABLE AT THE JOB SITE FOR REVIEW BY THE OWNERS' REPRESENTATIVE.
S-5. ALL BOLTED CONNECTIONS, UNLESS OTHERWISE NOTED, SHALL USE 3/4" DIAMETER HIGH STRENGTH
BOLTS WITH HARDENED CARBON STEEL WASHERS.
S-6. ALL FIELD-BOLTED SHEAR CONNECTIONS SHALL BE SNUG TIGHT BEARING-TYPE CONNECTIONS, THREADS INCLUDED IN THE SHEAR PLANE.
S-7. FIELD CUTTING OF STRUCTURAL STEEL MEMBERS BY ANY TRADE IS NOT PERMITTED. BOLT HOLES
SHALL NOT BE CUT OR ENLARGED BY FLAME CUTTING IN THE FIELD.
S-8. THE CONTRACTOR SHALL SUBMIT FOR APPROVAL DRAWINGS AND DESIGN CALCULATIONS FOR ANY
ALTERNATE DETAILS AND MEMBER SPLICES.
S-9. SHOP OR FIELD SPLICES OF STRUCTURAL STEEL MEMBERS ARE PROHIBITED EXCEPT AS DETAILED ON THE DRAWINGS, PERMITTED IN THE SPECIFICATIONS, AS INDICATED ON APPROVED SUBMITTALS, AND AS SPECIFICALLY APPROVED ON SHOP DRAWINGS PRIOR TO FABRICATION.
S-10. SPLICE PERIMETER BENT PLATE DECK CLOSURE DIRECTLY ABOVE A SUPPORTING STRUCTURAL
STEEL MEMBER.
S-11. ALL STEEL EXPOSED TO WEATHER SHALL BE HOT-DIPPED GALVANIZED IN ACCORDANCE WITH ASTM A123 FOR MEMBERS AND ASTM A153 FOR CONNECTION ELEMENTS, EXCEPT THAT ARCHITECTURALLY EXPOSED STRUCTURAL STEEL SHALL BE BLAST CLEANED AND COATED IN ACCORDANCE WITH THE
STRUCTURAL STEEL AND PAINT SPECIFICATIONS. COORDINATE ALL STEEL FINISHES WITH
ARCHITECTURAL DRAWINGS AND SPECIFICATIONS.
MASONRY CONSTRUCTION NOTES:
M-1. ALL MASONRY CONSTRUCTION SHALL BE IN ACCORDANCE WITH "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES" (TMS 402-16) AND "SPECIFICATION FOR MASONRY STRUCTURES" (TMS 602-16).
M-2. DESIGN MASONRY ASSEMBLAGE STRENGTH, f'm = 2000 PSI.
M-3. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 AND BE MANUFACTURED WITH NORMAL WEIGHT AGGREGATE. NET AREA COMPRESSIVE STRENGTH OF CONCRETE MASONRY UNITS SHALL BE
A MINIMUM OF 2650 PSI.
M-4. GROUT SHALL CONFORM TO ASTM C476 AND SHALL NOT CONTAIN ADMIXTURES. GROUT SHALL ATTAIN
A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 2000 PSI.
M-5. REINFORCEMENT SHALL BE DEFORMED BARS CONFORMING TO ASTM A615/A615M, GRADE 60 AND
SHALL HAVE FABRICATION TOLERANCES IN ACCORDANCE WITH ACI 315. SHOP FABRICATE
REINFORCING BARS WHICH ARE INDICATED TO BE BENT OR HOOKED.
M-6. LOCATE JOINT REINFORCEMENT 16 INCHES ON CENTER VERTICALLY AND ADDITIONALLY AT THE TOP OF ALL FOUNDATIONS AND IN THE TWO JOINTS IMMEDIATELY ABOVE AND BELOW ALL OPENINGS, EXTENDING A MINIMUM OF 24 INCHES BEYOND THE JAMB ON EACH SIDE.
M-7. PLACE PIPES AND CONDUITS PASSING HORIZONTALLY THROUGH MASONRY IN STEEL OR PVC SLEEVES
OR CORED HOLES UNLESS OTHERWISE INDICATED ON THE DRAWINGS.
M-8. ALUMINUM CONDUITS, PIPES, AND ACCESSORIES SHALL NOT BE EMBEDDED IN MASONRY GROUT, OR
MORTAR, UNLESS EFFECTIVELY COATED OR COVERED TO PREVENT ALUMINUM-CEMENT CHEMICAL
REACTION OR ELECTROLYTIC REACTION BETWEEN ALUMINUM AND STEEL.
M-9. UNLESS OTHERWISE NOTED OR DETAILED, CENTER WALL REINFORCEMENT IN BLOCK CELLS. USE
NONMETALLIC BAR POSITIONERS.
M-10. PROVIDE DOWEL REINFORCEMENT FROM WALLS INTO FOUNDATION OF SAME SIZE AND SPACING AS VERTICAL WALL REINFORCEMENT. LAP WALL REINFORCEMENT AS INDICATED IN SCHEDULE ON SF601.
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXCTA\Desktop\Tele-Work Revit Projects\Bsu001 (PN91397)\FY20PN91397_STRUC_R18_TW Current.rvt7/22/2020 8:56:35 AM
JU
LY
W
2H N
-2 0-
B-
C . A
TK
IN
S
C . A
TK
IN
S
S.
B
AR
BI
N A
0-
-0
S-002
G
EN
ER
AL
S
TR
U C
TU
R
AL
N
O
TE
S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
D U
C K, N O
R
TH
C
AR
O
LI
N A
FI
EL
D R
ES
EA
R C
H F
AC
IL
IT
Y
AN
N
EX
FY
, P
N
VO
LU
M E
-B
U
IL
D
IN
G
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
M
AR
K D
ES
C
R
IP
TI
O
N D
GABLE ROOF COMPONENT AND CLADDING WIND PRESSURES (PSF)
10 SF
EFFECTIVE
WIND
AREA
WALLOVERHANG ZONES
1. GROSS WIND PRESSURES SHOWN ABOVE ARE PREDICATED ON ULTIMATE WIND SPEED.
2. EDGE ZONES: 'a' = 5'-0"
3. WIND PRESSURES SHOWN SHALL BE USED IN CONJUNCTION WITH LOAD COMBINATIONS SPECIFIED IN
SECTIONS 2.3 AND 2.4 OF ASCE 7-16.
4. POSITIVE WIND PRESSURES REPRESENT WIND PRESSURES ACTING TOWARDS THE COMPONENT AND
CLADDING SURFACES.
5. NEGATIVE WIND PRESSURES REPRESENT WIND PRESSURES ACTING AWAY FROM THE COMPONENT
AND CLADDING SURFACES.
20 SF
50 SF
100 SF
+34 / -148 +55 / -60
+52 / -56
+49 / -54
+46 / -52
-125
-125
-98
-78
200 SF +44 / -49-78
250 SF +44 / -49-78
500 SF +31 / -46-78
2N, 2R, 3E
+29 / -128
+27 / -102
+22 / -82
+22 / -62
+22 / -55
+55 / -74
+52 / -69
+49 / -62
+46 / -57
+44 / -53
+44 / -53
+41 / -46
1, 2E 3E 4 5
ROOF ZONES
+22 / -55
-172
-157
-137
-120
-106
-102
-102
2N, 2R
-200
-174
-139
-111
-85
-78
-78
3R
-228
-195
-148
-116
-116
-116
-116
+34 / -176
3R
+29 / -151
+27 / -118
+22 / -92
+22 / -92
+22 / -92
+22 / -92
+34 / -102
1, 2E
+29 / -102
+27 / -62
+22 / -32
+22 / -32
+22 / -32
+22 / -32
10 PSF
17 PSF
3 PSF
FROM RIDGE
7' - 6"
UNBALANCED SNOW LOAD
6' - 0"
10 PSF
10 PSF
22.5 PSF MAX INTENSITY OF SURCHARGE LOAD
SNOW DRIFT LOADING
(HIGH ROOF / LOW ROOF HEADWALLS)
NOTE: THIS LOAD CASE SHALL BE MIRRORED ABOUT RIDGE.
E.5
5.2
'a
'a'
3e
3r
3e 3e
3r
3e3e
3e
2r
2r
2r
2e
2n 2n
3r 3r
2n
2n
2n
2e
3r
3r3r
3e 3e
2r
2e
2n 2n
2e
'2a'
'a
'2 a'
'2 a'
'4a' '4a'
'2a'
SOUTHWEST NORTHEAST
5 5
4 4
5 5
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXCTA\Desktop\Tele-Work Revit Projects\Bsu001 (PN91397)\FY20PN91397_STRUC_R18_TW Current.rvt7/22/2020 8:56:39 AM
JU
LY
W
2H N
-2 0-
B-
C . A
TK
IN
S
C . A
TK
IN
S
S.
B
AR
BI
N A
0-
-0
S-003
D
ES
IG
N
D
AT
A
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
D U
C K, N O
R
TH
C
AR
O
LI
N A
FI
EL
D R
ES
EA
R C
H F
AC
IL
IT
Y
AN
N
EX
FY
, P
N
VO
LU
M E
-B
U
IL
D
IN
G
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
COMPONENTS AND CLADDING WIND PRESSURES2
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
UNBALANCED SNOW LOADS DIAGRAMS1
1 2 3
4 5
6 7 8
B
C
D
E
F
G
A
3.5 5.94.6
8'
0"
7'
8"12' - 0" 13' - 4"
13' - 4" 13' - 1" 13' - 1"
13' - 1" 13' - 1"
5' - 7" 7' - 9" 11' - 0"
2' - 1"
15' - 11" 15' - 11"
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXCTA\Desktop\Tele-Work Revit Projects\Bsu001 (PN91397)\FY20PN91397_STRUC_R18_TW Current.rvt7/22/2020 8:56:44 AM
JU
LY
W
2H N
-2 0-
B-
C . A
TK
IN
S
C . A
TK
IN
S
S.
B
AR
BI
N A
0-
-0
SB101
PI
LE
L
AY
O U
T
PL
AN
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
D U
C K, N O
R
TH
C
AR
O
LI
N A
FI
EL
D R
ES
EA
R C
H F
AC
IL
IT
Y
AN
N
EX
FY
, P
N
VO
LU
M E
-B
U
IL
D
IN
G
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
PILE LAYOUT PLAN1
1 8
B
G
91' - 0"
ELEVATED DECK PLAN NOTES:
1. FOR GENERAL STRUCTURAL NOTES AND ABBREVIATIONS,
SEE S-001 AND S-002.
2. SEE SF201 AND FOLLOWING FOR FRAMING ELEVATIONS.
3. SEE SF501 AND FOLLOWING FOR CONCRETE SECTIONS
AND DETAILS.
4. SEE SF504 AND FOLLOWING FOR MASONRY DETAILS AND
SCHEDULES.
5. TOP OF INTERIOR SLAB ELEVATION = 0'-0".
ALL ELEVATIONS INDICATED FROM THIS DATUM.
TOP OF INTERIOR SLAB ELEVATION CORRESPONDS TO
CIVIL ELEVATION OF 25.00'
6. TOP OF ELEVATED SLAB ELEVATION = (-)0'-8". TOP OF
ELEVATED SLAB SLOPES DOWN APPROX 1/8" PER FOOT
AT EXTERIOR CONDITITION. SEE PLAN FOR EXACT
ELEVATIONS.
7. TOP OF STEEL BASE PLATE ELEVATION = (-)1'-1 1/4".
8. INTERIOR SLAB SHALL CONSIST OF 4" THICK CONCRETE
REINFORCED WITH 6X6 W2.9XW2.9 WWF LOCATED AT 1/3-
DEPTH FROM TOP OF SLAB.
9. INTERIOR SLAB SHALL BE PLACED ON 10 MIL VAPOR
RETARDER ON 4" RIGID INSULATION.
10. PROVIDE (1) #5 X 4'-0" LONG IN INTERIOR SLAB AT ALL
RE-ENTRANT CORNERS.
11. PROVIDE (1) #5 X 4-0" LONG @ 12" OC ACROSS EMBEDDED
CONDUIT. PROVIDE MIN 1" CLEAR FROM TOP OF SLAB.
12. INTERIOR SLAB SHALL HAVE SAWED CONTRACTION
JOINTS. JOINT SPACING SHALL NOT EXCEED MAXIMUM
JOINT SPACING PER ACI REQUIREMENTS.
13. ELEVATED SLAB SHALL NOT HAVE SAWED CONTRACTION
JOINTS.
14. COORDINATE UNDERGROUND UTILITY LINES WITH CIVIL
AND PLUMBING DRAWINGS PRIOR TO CONSTRUCTION OF
FOUNDATIONS.
FD
FLOOR DRAIN / CLEANOUT
(COORD W/ ARCH AND MEP)
RE-ENTRANT CORNER BARS
DEPRESSED SLAB
X CMU WALL TYPE, SEE SF601
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXCTA\Desktop\Tele-Work Revit Projects\Bsu001 (PN91397)\FY20PN91397_STRUC_R18_TW Current.rvt7/22/2020 8:56:49 AM
JU
LY
W
2H N
-2 0-
B-
C . A
TK
IN
S
C . A
TK
IN
S
S.
B
AR
BI
N A
0-
-0
SF100
EL
EV
AT
ED
D
EC
K C
O M
PO
SI
TE
P
LA
N
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
D U
C K, N O
R
TH
C
AR
O
LI
N A
FI
EL
D R
ES
EA
R C
H F
AC
IL
IT
Y
AN
N
EX
FY
, P
N
VO
LU
M E
-B
U
IL
D
IN
G
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
ELEVATED DECK COMPOSITE PLAN1 0' 4' 8' 12'
SCALE: 1/4" = 1' - 0"
PLAN NORTH TRUE NORTH
6 7 8
B
C
D
E
F
G
1'
3" 8'
0"
7'
0"
SF501
E.5
5.2
6'
7/
8" 5'
1/ 8"
6.9
A
7'
8"
3' - 4" 12' - 0" 13' - 4"
13' - 4" 13' - 1" 13' - 1"
13' - 1" 13' - 1" 5' - 10"
3.5 5.9
5' - 7" 7' - 9" 11' - 0"
2' - 1"
SF501
SF501
FD
FD
FD
FD
SF501
4.6 15' - 11" 15' - 11"
HSS4X
4X
5/1
HSS4X
4X
5/1
HSS4X
4X
5/1
HSS4X
4X
5/1
HSS4X
4X
5/1
HSS4X
4X
5/1
SF505
SF505
TOC -9 1/2"
TOC -8"
TOC -8"
TOC -9 1/2"
TOC -8"TOC -9 1/2" TOC -8" TOC -9 1/2"
T/BEAM -1' - 4"
T/BEAM -1' - 4"
TOC -11"
T/BEAM -1' - 5 1/2"
T/BEAM -1' - 5 1/2"
T/BEAM -1' - 7"
FD
FD
FD
MCJ
MCJ
MCJ
MCJ
MCJ
MCJ
MCJ
MCJ
M C
J
M C
J
M C
J
M C
J
M C
J
M C
J
M C
J
M C
J
W1
W3
W1
W2 W3 W3W2
W3
W2
W3
W3
W3
W3
W3 W3
2' - 10 3/4"
2' - 1 1/4"
SF501
SF501
SF501
CB24x22.5
CB24x24
CB24x24
CB24x24
CB24x24
CB24x24
CB12x22.5
C B1
2x
.5
C B1
2x
.5
C B2
4x
C B2
4x
C B2
4x
C B2
4x
CB24x24
C B2
4x
C B2
4x
C B2
4x
C B2
4x
C B2
4x
C B2
4x
T/BEAM -1' - 5 1/2"
T/BEAM -1' - 5 1/2"T/BEAM -1' - 4"
T/BEAM -1' - 4"
CB24x21
SF501
SIM
SF501
C B2
4x
SF502
SF501
SF501
SF502
SIM
SF502
SF503
SF503
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXCTA\Desktop\Tele-Work Revit Projects\Bsu001 (PN91397)\FY20PN91397_STRUC_R18_TW Current.rvt7/22/2020 8:56:54 AM
JU
LY
W
2H N
-2 0-
B-
C . A
TK
IN
S
C . A
TK
IN
S
S.
B
AR
BI
N A
0-
-0
SF101A
EL
EV
AT
ED
D
EC
K
PL
AN
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
D U
C K, N O
R
TH
C
AR
O
LI
N A
FI
EL
D R
ES
EA
R C
H F
AC
IL
IT
Y
AN
N
EX
FY
, P
N
VO
LU
M E
-B
U
IL
D
IN
G
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
ELEVATED DECK PLAN1 0' 4' 8' 12'
SCALE: 1/4" = 1' - 0"
M
AR
K D
ES
C
R
IP
TI
O
N D
6 7 8
B
C
D
E
F
G
A
3.5 5.94.6
1'
3" 8'
0"
7'
0"
3' - 4" 12' - 0" 13' - 4" 13' - 1" 13' - 1" 5' - 10"
FD
FD
FD
FD
TOC -9 1/2"
TOC -8"
TOC -8"
TOC -9 1/2"
TOC -8"TOC -9 1/2"
TOC -8" TOC -9 1/2"
2"
2"
TOC -11"
FD
FD
FD
MCJ
MCJ
MCJ
MCJ
MCJ
MCJ
MCJ
MCJ
M C
J
M C
J
M C
J
M C
J
M C
J
M C
J
M C
J
M C
J
W1
W3
W1
W2 W3 W3W2
W3
W2
W3
W3
W3
W3
W3 W3TOC 0"
TOS 0"
TOC 0"
SJ
SJ
SJ
SJ
SJ
SJ
SJ
SJ
SJ
SJ
SJ
SJ
SJ
SJ
SJ
SJ
SJ
SJ
SJ
SJ
SJ
SJ
SJ
SJ SJ SJ
SJ
SJ
SJ SJ SJ SJ
SJ SJ SJ SJ
SJ SJ SJ SJ
SJ SJ SJ SJ
SJ
SJ
SJ
SJ
SJ
SJ
SJ
TOC 0"
SJ
SJ SJ
SJ SJ
SJ
SJ
SJ
SJ
SJ
SJ
SJ
SJ
SJ
SF502
SF501
SF501
SF501
SF501
SF502
SIM
15' - 11" 15' - 11"
8'
0" 8'
0"
SF502
SF502
SF502
SIM SIM
SF503
5' - 7"
2' - 1"
13' - 1"
7'
8"
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXCTA\Desktop\Tele-Work Revit Projects\Bsu001 (PN91397)\FY20PN91397_STRUC_R18_TW Current.rvt7/22/2020 8:56:59 AM
JU
LY
W
2H N
-2 0-
B-
C . A
TK
IN
S
C . A
TK
IN
S
S.
B
AR
BI
N A
0-
-0
SF101B
IN
TE
R
IO
R S
LA
B
PL
AN
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
D U
C K, N O
R
TH
C
AR
O
LI
N A
FI
EL
D R
ES
EA
R C
H F
AC
IL
IT
Y
AN
N
EX
FY
, P
N
VO
LU
M E
-B
U
IL
D
IN
G
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
0' 4' 8' 12'
SCALE: 1/4" = 1' - 0"INTERIOR SLAB PLAN1
1 8
B B
A
3.5 5.9
4.6
SF503
-1"
-1"
5'
0" 5'
0"
5'
0" 5'
0"
C
LR
4'
4"
C
LR
4'
4"
C
LR
4'
4"
C
LR
4'
4"
CLR
5' - 0"
5' - 8"
SF503
5' - 3"
SF503
1" / 12"
1" / 12"
1" / 12"
1" / 12"
1/8" / 12"
8'
1/8" / 12"
3'
0"
1/ 8"
1/
8"
1/ 8"
1/
8"
5'
9"
4"H x 10"W
THRU WALL SCUPPER
4"H x 10"W
THRU WALL SCUPPER
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXCTA\Desktop\Tele-Work Revit Projects\Bsu001 (PN91397)\FY20PN91397_STRUC_R18_TW Current.rvt7/22/2020 8:57:04 AM
JU
LY
W
2H N
-2 0-
B-
C . A
TK
IN
S
C . A
TK
IN
S
S.
B
AR
BI
N A
0-
-0
SF102
EL
EV
AT
ED
D
EC
K
AC
C
ES
S
PL
AN
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
D U
C K, N O
R
TH
C
AR
O
LI
N A
FI
EL
D R
ES
EA
R C
H F
AC
IL
IT
Y
AN
N
EX
FY
, P
N
VO
LU
M E
-B
U
IL
D
IN
G
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
ELEVATED DECK ACCESS PLAN1 0' 4' 8' 12'
SCALE: 1/4" = 1' - 0"
M
AR
K D
ES
C
R
IP
TI
O
N D
2 8
C
E
G
SF507
SF507
SPACED AS SHOWN
20K
SPACED AS SHOWN
12K
2"
2"
2"
79' - 0"
W12X26 W12X26
W12X26 W12X26 W12X26 W10X19 W10X19
BELOW BELOW BELOW
W
X1
W
X1
W
X1
BE
LO
W
BE
LO
W
BE
LO
W
TOS 16' - 0 1/2"
TOS 20' - 5 1/2"
TOS 14' - 11 5/8"
SF507
SPACED AS SHOWN
16K
SF507
SF507
SF507
SF507
SF507
SF507
SF508
W10X19
SF508
SPACED AS SHOWN
16KSP 16K
2"
HSS 7x3x3/8 (LLH)
1' - 3" @ 2'-3" OC
W
X1
W
X1
W
X1
DECK SPAN
DECK SPAN
4' - 5" 4' - 6" 4' - 5"4' - 4" 4' - 6" 4' - 6" 4' - 0" 4' - 0" 4' - 0" 3' - 11 3/4"
SF507
3' - 2" 4' - 6" 4' - 6" 4' - 6" 4' - 6" 4' - 6" 4' - 0" 4' - 0" 2' - 8 1/4"
4' - 6" 4' - 6" 4' - 5" 4' - 6" 4' - 5" 4' - 0" 4' - 0" 4' - 0" 3' - 4"
SF508
SF506
SF506
SF507
ROOF PLAN NOTES:
1. FOR GENERAL STRUCTURAL NOTES AND ABBREVIATIONS,
SEE S-001 AND S-002.
2. SEE SF201 AND FOLLOWING FOR ELEVATIONS.
3. SEE SF507 AND FOLLOWING FOR ROOF SECTIONS AND
DETAILS.
4. ROOF DECK SHALL BE 1.5B20 GAUGE METAL DECK WITH A
36/4 FASTENING PATTERN WITH 4 SIDELAPS. SUPPORT
FASTENERS SHALL BE 5/8" DIA PUDDLE WELDS AND
SIDELAP FASTENERS ARE TO BE #10 TEK SCREWS.
PROVIDE 5/8" DIA PUDDLE WELDS @ 6" OC AROUND THE
PERIMETER DECK SUPPORTS AND PERIMETER DECK EDGE.
5. PROVIDE CONT 3/16" THICK, 12" WIDE BENT PLATE
@ ALL RIDGES.
6. PROVIDE CONT 5X5X3/16" BENT PLATE DECK CLOSURE AND
CONT 12X3/16" PLATE @ THE EDGE OF ALL ROOF DECK.
7. SPLICE PERIMETER BENT PLATE DECK CLOSURE DIRECTLY
ABOVE A SUPPORTING STRUCTURAL STEEL MEMBER.
8. JOIST SUPPLIER TO DESIGN AND PROVIDE ALL BRIDGING
AND BRACING TO COMPLY WITH SJI AND OSHA
REQUIREMENTS. THIS IS TO INCLUDE UPLIFT BRIDGING.
9. JOIST AND JOIST SUBSTITUTE SPACING IS 4'-6" OC MAX.
10. REFER TO PLAN AND FRAME ELEVATIONS FOR STEEL BEAM
ELEVATIONS. BEAMS PARALLEL WITH JOIST, SLOPE WITH
JOIST.
11. COORDINATE ALL ROOF DIMENSIONS, ELEVATIONS,
OPENINGS AND PENETRATIONS WITH ARCHITECTURAL,
MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS.
SEE ARCHITECTURAL DRAWINGS FOR ROOF PENETRATION
WATERPROOFING DETAILS.
1 200 LB SUSPENDED MECH EQUIPMENT
2 100 LB SUSPENDED MECH EQUIPMENT
3 125 LB SUSPENDED MECH EQUIPMENT
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXCTA\Desktop\Tele-Work Revit Projects\Bsu001 (PN91397)\FY20PN91397_STRUC_R18_TW Current.rvt7/22/2020 8:57:11 AM
JU
LY
W
2H N
-2 0-
B-
C . A
TK
IN
S
C . A
TK
IN
S
S.
B
AR
BI
N A
0-
-0
SF120
R O
O F
FR
AM
IN
G
P
LA
N
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
D U
C K, N O
R
TH
C
AR
O
LI
N A
FI
EL
D R
ES
EA
R C
H F
AC
IL
IT
Y
AN
N
EX
FY
, P
N
VO
LU
M E
-B
U
IL
D
IN
G
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
ROOF FRAMING PLAN1 0' 4' 8' 12'
SCALE: 1/4" = 1' - 0"
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
PLAN NORTH TRUE NORTH
ELEVATED DECK
-8"
7' - 10 5/8" 16' - 8" 18' - 8"
13' - 8" 9' - 4" 13' - 5 1/2"MCJ MCJ
BOND BEAM
W/ (2) # 5 CONT
8" DEEP CONCRETE TIE BEAM
W/ (2) # 5 CONT
BOND BEAM
W/ (2) # 5 CONT
JAMB, SILL, AND FIELD REINF NOT SHOWN,
SEE PLAN AND SCHEDULES FOR REINF
SIZE AND SPACING
MCJ MCJMCJ
BOND BEAM
W/ (2) # 5 CONT
8" DEEP CONCRETE TIE BEAM
W/ (2) # 5 CONT
BOND BEAM
W/ (2) # 5 CONT
16" BOND BEAM
W/ (2) # 5 T & B
W3 W3 W3
W2 W2 W2
12' - 0"
TOC
15' - 4"
TOC
CLOSED CELL LINTEL BLOCK ONLY
ABOVE OPENINGS
2 8
ELEVATED DECK
-8"
MCJ MCJ MCJ
23' - 8" 20' - 8" 19' - 4" 16' - 0"
BOND BEAM
W/ (2) # 5 CONT
8" DEEP CONCRETE TIE BEAM
W/ (2) # 5 CONT
BOND BEAM
W/ (2) # 5 CONT
JAMB, SILL, AND FIELD REINF NOT SHOWN,
SEE PLAN AND SCHEDULES FOR REINF
SIZE AND SPACING
W3 W3 W3 W3
12' - 0"
TOC
12' - 0"
TOC
CLOSED CELL LINTEL BLOCK ONLY
ABOVE OPENINGS
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXCTA\Desktop\Tele-Work Revit Projects\Bsu001 (PN91397)\FY20PN91397_STRUC_R18_TW Current.rvt7/22/2020 8:57:21 AM
JU
LY
W
2H N
-2 0-
B-
C . A
TK
IN
S
C . A
TK
IN
S
S.
B
AR
BI
N A
0-
-0
SF201
FR
AM
IN
G
E
LE
VA
TI
O N
S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
D U
C K, N O
R
TH
C
AR
O
LI
N A
FI
EL
D R
ES
EA
R C
H F
AC
IL
IT
Y
AN
N
EX
FY
, P
N
VO
LU
M E
-B
U
IL
D
IN
G
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
PLAN NORTH SHEAR WALL2
PLAN SOUTH SHEAR WALL1
0' 4' 8' 12'
SCALE: 1/4" = 1' - 0"
0' 4' 8' 12'
SCALE: 1/4" = 1' - 0"
M
AR
K D
ES
C
R
IP
TI
O
N D
BCG
-8"
2' - 0" 18' - 8" 17' - 4" 8' - 8" 2' - 0"MCJ
BOND BEAM
W/ (2) # 5 CONT
16" DEEP CONCRETE TIE BEAM
W/ (2) # 5 CONT TOP AND BOT,
STEP BLOCK BELOW AS
REQUIRED
BOND BEAM
W/ (2) # 5 CONT
JAMB, SILL, AND FIELD REINF NOT SHOWN,
SEE PLAN AND SCHEDULES FOR REINF
SIZE AND SPACING
MCJ MCJ MCJ
W3 W3 W3
12' - 0"
TOC
12' - 0"
TOC
TOC
CLOSED CELL LINTEL BLOCK ONLY
ABOVE OPENINGS
16' - 0"
1' - 4" 1'
4"
2' - 8" 4' - 0" 2' - 8"
4' - 0"
B C G
ELEVATED DECK
-8"
2' - 0" 19' - 4" 16' - 8" 8' - 8" 2' - 0"MCJ
16" BOND BEAM
W/ (2) # 5 T & B
16" DEEP CONCRETE TIE BEAM
W/ (2) # 5 CONT TOP AND BOT,
STEP BLOCK BELOW AS REQUIRED
BOND BEAM
W/ (2) # 5 CONT
JAMB, LINTEL, SILL, AND FIELD REINF NOT SHOWN,
SEE PLAN AND SCHEDULES FOR REINF SIZE AND
SPACING
MCJ MCJ MCJ
BOND BEAM
W/ (2) # 5 CONT
16" DEEP CONCRETE TIE BEAM
W/ (2) # 5 CONT TOP AND BOT,
STEP BLOCK BELOW AS REQUIRED
BOND BEAM
W/ (2) # 5 CONT
W1 W1 W3
20' - 7"
TOC
15' - 4"
TOC
12' - 0"
TOC
14' - 10 1/2"
TOC
1' - 4"
1'
4"
CLOSED CELL LINTEL BLOCK ONLY
ABOVE OPENINGS
SF508 2
SF508
1' - 4"
1' - 4"
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .