2021-09-09_JBLM-B9175-REV-04-DWGS_AMENDMENT 6.pdf

PDF 29 MB Posted

Attached to
“Repair Building 09175, Permanent Party UH” located on Joint Base Lewis-McChord, WA
Solicitation number
W912DW21B0008
Issued by

About this file

This file is a summary of Federal Solicitation Number W912DW21B0008 for repair work on Building 09175 located at Joint Base Lewis-McChord in Washington. The solicitation was issued by the Department of the Army Corps of Engineers Engineering District Seattle to repair the permanent party unaccompanied housing building. Offerors must submit responses by the specified due date to be considered for award of a firm fixed price construction contract to complete repairs on the building's HVAC, electrical, and plumbing systems. The work includes replacement of equipment and materials to remedy deficiencies and return the building to like-new condition.

View the file

Other files

File Type Posted
Abstract REV1 W912DW21B0008 Repair Building 9175 Permanent Party UH (SAM.gov).pdf PDF
Abstract W912DW21B0008 Repair Building 9175 Permanent Party UH (SAM.gov).pdf PDF
Amendment 0006 W912DW21B0008 Repair Bldg 9175.pdf PDF
JBLM DPW Geospatial BIM CIM GIS and CAD Contract Requirements FY21_AMENDMENT 6.pdf PDF
2021-09-09-JBLM-B9175-REV-04-SPECS_AMENDMENT 6.pdf PDF
202109XX_CE0849 SOW_09175_AMENDMENT 6.pdf PDF
26 20 00-INTERIOR DISTRIBUTION SYSTEM-REVISION 03_AMENDMENT 5.pdf PDF
Amendment 0005 W912DW21B0008 Repair Bldg 9175.pdf PDF
20210831_Sign in Roster Repair Bldg 09175 Site Visit 2_AMENDMENT 5.pdf PDF
2021-09-03-JBLM-B9175-DWGS-REVISION 03-AMENDMENT 5.pdf PDF
DDC Controls As-Builts_AMENDMENT 0004.pdf PDF
Amendment 0004 W912DW21B0008 Repair Bldg 9175.pdf PDF
2021-08-20-JBLM-B9175-DWGS-REVISION 01-AMENDMENT 2.pdf PDF
2021-08-20-JBLM-B9175-SPECS-REVISION 01-AMENDMENT 2.pdf PDF
Amendment 0003 W912DW21B0008 Repair Bldg 9175.pdf PDF
Amendment 0002 W912DW21B0008 Repair Bldg 9175.pdf PDF
12 32 00-Manufactured Wood Casework-EDITED-REV 02-ISSUED_AMENDMENT 0003.pdf PDF
20210824_9175 Meeting Attendance Roster_AMENDMENT 0003.pdf PDF
01 30 00-Administrative Requirements-EDITED-REV 02_AMENDMENT 0003.pdf PDF
9175-Submittal Register_AMENDMENT 2.xlsx XLSX spreadsheet
20210820_CE0849 SOW_09175_AMENDMENT 2.pdf PDF
W912DW21B0008 Repair Bldg 9175.pdf PDF
9175 Location Site Visit Map.pdf PDF
2021-08-11_B9175 Submittal Register.xlsx XLSX spreadsheet
2021-08-10-JBLM 9175-SPECS-RTA REV001.pdf PDF
20210810_CE0849 SOW_09175.pdf PDF
JA Brand Names or Equal_JBLM 9175-Interior Finishes_Redacted.pdf PDF
Bldg 9175-Final Environmental Report.pdf PDF
Amendment 0001 W912DW21B0008 Repair Bldg 9175.pdf PDF
Barracks Buildings 9175 and 9176 as builts.pdf PDF
2021-08-10_JBLM-B9175-RTA-DWGS-REV01_Part2.pdf PDF
2021-08-10_JBLM-B9175-RTA-DWGS-REV01_Part1.pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INDEX OF DRAWINGS

NUMBERING SYSTEM:

XX100

DISCIPLINE:

C - CIVIL

L - LANDSCAPE

A - ARCHITECTURE

M - MECHANICAL

E - ELECTRICAL

P - PLUMBING

S - STRUCTURAL

K - FOOD SERVICE

DISCIPLINE MODIFIER

SHEET NUMBER WITHIN

SERIES

REFER TO AEC CAD

STANDARDS FOR PROPER

SHEET NUMBERING

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

GI002

S H

E E

T I

N D

E X

J O

IN

T

B A

S E

L E

W

IS

-M C

C H

O R

D W

A

S E

A T

T L E

D

IS

T R

IC

T

E

M

A R

G

IN

A L W

A Y

S O

U T

H B

L D

G

S E

A T

T L E

W

A

-2

Y A

E G

E R

A R

C H

IT

E

C T

U R

E

P

E N

R O

S E

L A

N E

S

U

IT

E

L E

N E

X A

K

S

K C

O U

G H

L

IN

K C

O U

G H

L

IN

C P

R Z

Y G

O D

A

M T

U R

N E

R

S

E P

T E

M B

E R

T B

D

T B

D

REVISION 04, AMENDMENT

R E

P A

IR

B

U

IL

D

IN

G

D E

S

IG

N C

O N

S T

R U

C T

IO

N

P K

G N

O C

E C

E

INDEX OF DRAWINGS

SHEET

NUMBER SHEET TITLE

RTA

SUBMITTAL

REVISION

REVISION

REVISION

M-603 MECHANICAL SCHEDULES X

M-701 TEMPERATURE CONTROLS X

M-702 TEMPERATURE CONTROLS X

M-703 TEMPERATURE CONTROLS X

M-704 TEMPERATURE CONTROLS X X

M-705 TEMPERATURE CONTROLS X X

ELECTRICAL

E-001 ELECTRICAL GENERAL NOTES AND SYMBOLS X

ED101 ELECTRICAL OVERALL FIRST FLOOR DEMOLITION PLAN X

ED111 ELECTRICAL OVERALL SECOND FLOOR DEMOLITION PLAN X

ED121 ELECTRICAL OVERALL THIRD FLOOR DEMOLITION PLAN X

ED100 ELECTRICAL SITE DEMOLITION PLAN X

ES101 ELECTRICAL SITE PLAN X

EP102 ELECTRICAL FIRST FLOOR POWER PLAN - AREA B X

EP103 ELECTRICAL FIRST FLOOR POWER PLAN - AREAS A AND C X

EP112 ELECTRICAL SECOND FLOOR POWER PLAN - AREA B X

EP113 ELECTRICAL SECOND FLOOR POWER PLAN - AREAS A AND C X

EP122 ELECTRICAL THIRD FLOOR POWER PLAN - AREA B X

EP123 ELECTRICAL THIRD FLOOR POWER PLAN - AREAS A AND C X

EP401 ELECTRICAL ENLARGED POWER PLANS X

EP402 ELECTRICAL ENLARGED POWER PLANS X

EL102 ELECTRICAL FIRST FLOOR LIGHTING PLAN - AREA B X

EL103 ELECTRICAL FIRST FLOOR LIGHTING PLAN - AREAS A AND C X

EL112 ELECTRICAL SECOND FLOOR LIGHTING PLAN - AREA B X

EL113 ELECTRICAL SECOND FLOOR LIGHTING PLAN - AREAS A AND C X

EL122 ELECTRICAL THIRD FLOOR LIGHTING PLAN - AREA B X

EL123 ELECTRICAL THIRD FLOOR LIGHTING PLAN - AREAS A AND C X

EL401 ELECTRICAL ENLARGED LIGHTING PLANS X

E-501 ELECTRICAL DETAILS X

E-502 ELECTRICAL DETAILS X

E-601 ELECTRICAL ONE-LINE DIAGRAM - DEMOLITION X

E-602 ELECTRICAL ONE-LINE DIAGRAM - PROPOSED X

E-603 ELECTRICAL SCHEDULES X

E-604 ELECTRICAL SCHEDULES X

E-605 ELECTRICAL SCHEDULES X

E-606 ELECTRICAL SCHEDULES X

E-607 ELECTRICAL SCHEDULES X

E-608 ELECTRICAL SCHEDULES X

E-609 ELECTRICAL SCHEDULES X

TELECOMMUNICATIONS

T0-01 TELECOMMUNICATIONS GENERAL NOTES AND SYMBOLS X

T0-02 TELECOMMUNICATIONS SITE PLAN X

T0-03 TELECOMMUNICATIONS SITE PLAN X

T0-04 TELECOM MANHOLE BUTTERFLY DIAGRAMS X

T1-01 TELECOMMUNICATIONS FIRST FLOOR DEMO PLAN X

T1-02 TELECOMMUNICATIONS SECOND FLOOR DEMO PLAN X

T1-03 TELECOMMUNICATIONS THIRD FLOOR DEMO PLAN X

T1-11 TELECOMMUNICATIONS FIRST FLOOR DISTRIBUTION PLAN X

T1-12 TELECOMMUNICATIONS SECOND FLOOR DISTRIBUTION PLAN X

T1-13 TELECOMMUNICATIONS THIRD FLOOR DISTRIBUTION PLAN X

T1-21 TELECOMMUNICATIONS FIRST FLOOR PATHWAY PLAN X

T1-22 TELECOMMUNICATIONS SECOND FLOOR PATHWAY PLAN X

T1-23 TELECOMMUNICATIONS THIRD FLOOR PATHWAY PLAN X

T2-11 TELECOMMUNICATIONS FIRST FLOOR PLAN - AREA B X

T2-12 TELECOMMUNICATIONS FIRST FLOOR PLAN - AREAS A AND C X

T2-21 TELECOMMUNICATIONS SECOND FLOOR PLAN - AREA B X

T2-22 TELECOMMUNICATIONS SECOND FLOOR PLAN - AREAS A AND C X

T2-31 TELECOMMUNICATIONS THIRD FLOOR PLAN - AREA B X

T2-32 TELECOMMUNICATIONS THIRD FLOOR PLAN - AREAS A AND C X

T3-01 TELECOMMUNICATIONS ENLARGED FLOOR PLANS X

T3-02 NEC COMM 154 ELEVATIONS X

T3-03 NEC COMM 258 ELEVATIONS X

T3-04 NEC COMM 358 ELEVATIONS X

T3-05 NEC COMM 109 ELEVATIONS X

T3-06 NEC COMM 209 ELEVATIONS X

T3-07 NEC COMM 309 ELEVATIONS X

T4-01 TELECOMMUNICATIONS DETAILS X

T4-02 TELECOMMUNICATIONS DETAILS X

T4-03 TELECOMMUNICATIONS RISER DIAGRAMS X

INDEX OF DRAWINGS

SHEET

NUMBER SHEET TITLE

RTA

SUBMITTAL

REVISION

REVISION

REVISION

AE606 DOOR HARDWARE X

AE607 WINDOW SCHEDULE AND TYPES X X

INTERIOR DESIGN

IN102 FIRST FLOOR AREA-B FINISH PLAN X

IN201 ENLARGED UNIT FINISH PLANS X

IN252 FIRST FLOOR SIGNAGE PLAN - AREA B X X

IN253 FIRST FLOOR SIGNAGE PLAN - AREA A AND C X X

IN262 SECOND FLOOR SIGNAGE PLAN - AREA B X X

IN263 SECOND FLOOR SIGNAGE PLAN - AREA A AND C X

IN272 THIRD FLOOR SIGNAGE PLAN - AREA B X X

IN273 THIRD FLOOR SIGNAGE PLAN - AREA A AND C X

IN401 INTERIOR ELEVATIONS X X

IN402 INTERIOR ELEVATIONS X

IN501 INTERIOR DETAILS X

IN531 SIGNAGE DETAILS X X

IN532 SIGNAGE DETAILS X X

IN601 INTERIOR FINISH LEGEND X

IN602 INTERIOR FINISH SCHEDULE X X

FURNITURE

IF101 OVERALL FIRST FLOOR FURNITURE PLAN X

IF102 FIRST FLOOR AREA-B FURNITURE PLAN X

IF111 OVERALL SECOND FLOOR FURNITURE PLAN X

IF121 OVERALL THIRD FLOOR FURNITURE PLAN X

IF401 ENLARGED UNIT FURNITURE PLANS X

FIRE PROTECTION

FA001 FIRE ALARM NOTES AND DETAILS X

FX001 FIRE SPRINKLER NOTES AND DETAILS X

FD101 FIRE ALARM DEMOLITION PLAN - FIRST FLOOR X

FD111 FIRE ALARM DEMOLITION PLAN - SECOND FLOOR X

FD121 FIRE ALARM DEMOLITON PLAN - THIRD FLOOR X

FA101 FIRE ALARM PLAN FIRST FLOOR X

FA102 FIRE ALARM PLAN FIRST FLOOR - AREA B X

FA103 FIRE ALARM PLAN FIRST FLOOR - AREA A & C X

FA111 FIRE ALARM PLAN SECOND FLOOR X

FA112 FIRE ALARM PLAN SECOND FLOOR - AREA B X

FA113 FIRE ALARM PLAN SECOND FLOOR - AREA A & C X

FA121 FIRE ALARM PLAN THIRD FLOOR X

FA122 FIRE ALARM PLAN THIRD FLOOR - AREA B X

FA123 FIRE ALARM PLAN THIRD FLOOR - AREA A & C X

FX101 FIRE SPRINKLER PLAN FIRST FLOOR X

FX102 FIRE SPRINKLER PLAN FIRST FLOOR - AREA B X

FX103 FIRE SPRINKLER PLAN FIRST FLOOR - AREA A & C X

FX111 FIRE SPRINKLER PLAN SECOND FLOOR X

FX112 FIRE SPRINKLER PLAN SECOND FLOOR - AREA B X

FX113 FIRE SPRINKLER PLAN SECOND FLOOR - AREA A & C X

FX121 FIRE SPRINKLER PLAN THIRD FLOOR X

FX122 FIRE SPRINKLER PLAN THIRD FLOOR - AREA B X

FX123 FIRE SPRINKLER PLAN THIRD FLOOR - AREA A & C X

PLUMBING

M-001 MECHANICAL COVER SHEET X

PD101 PLUMBING DEMOLITION PLAN - FIRST FLOOR X

PD111 PLUMBING DEMOLITION PLAN - SECOND FLOOR X

PD121 PLUMBING DEMOLITION PLAN - THIRD FLOOR X

PP101 OVERALL FIRST FLOOR PLUMBING PLAN X

PP102 FIRST FLOOR AREA B PLUMBING PLAN X

PP103 FIRST FLOOR AREA A AND C PLUMBING PLAN X

PP111 OVERALL SECOND FLOOR PLUMBING PLAN X

PP112 SECOND FLOOR AREA B PLUMBING PLAN X

PP113 SECOND FLOOR AREA A AND C PLUMBING PLAN X

PP121 OVERALL THIRD FLOOR PLUMBING PLAN X

PP122 THIRD FLOOR AREA B PLUMBING PLAN X

PP123 THIRD FLOOR AREA A AND C PLUMBING PLAN X

P-401 ENLARGED PLUMBING PLANS X

P-402 ENLARGED PLUMBING PLANS X

P-403 ENLARGED PLUMBING PLANS - AREA B X

P-501 PLUMBING DETAILS X

P-502 PLUMBING DETAILS X

P-601 PLUMBING SCHEDULES X

P-901 PLUMBING ISOMETRICS X

P-902 PLUMBING ISOMETRICS X

P-903 PLUMBING ISOMETRICS X

P-904 PLUMBING ISOMETRICS X

MECHANICAL

MD101 OVERALL FIRST FLOOR HVAC DEMOLITION PLAN X

MD111 OVERALL SECOND FLOOR HVAC DEMOLITION PLAN X

MD121 OVERALL THIRD FLOOR HVAC DEMOLITION PLAN X

MD131 OVERALL ATTIC HVAC DEMOLITION PLAN X

MH101 OVERALL FIRST FLOOR HVAC PLAN X

MH102 FIRST FLOOR AREA B HVAC PLAN X

MH103 FIRST FLOOR AREA A AND C HVAC PLAN X

MH111 OVERALL SECOND FLOOR HVAC PLAN X

MH112 SECOND FLOOR AREA B HVAC PLAN X

MH113 SECOND FLOOR AREA A AND C HVAC PLAN X

MH121 OVERALL THIRD FLOOR HVAC PLAN X

MH122 THIRD FLOOR AREA B HVAC PLAN X

MH123 THIRD FLOOR AREA A AND C HVAC PLAN X

MH131 ATTIC PLAN AREA B X

MH132 ATTIC PLAN AREA A AND C X

MP101 OVERALL FIRST FLOOR HYDRONIC PLAN X

MP102 FIRST FLOOR AREA B HYDRONIC PLAN X X

MP103 FIRST FLOOR AREA A AND C HYDRONIC PLAN X X

MP111 OVERALL SECOND FLOOR HYDRONIC PLAN X

MP112 SECOND FLOOR AREA B HYDRONIC PLAN X X

MP113 SECOND FLOOR AREA A AND C HYDRONIC PLAN X X

MP121 THIRD FLOOR OVERALL HYDRONIC PLAN X

MP122 THIRD FLOOR AREA B HYDRONIC PLAN X X

MP123 THIRD FLOOR AREA A AND C HYDRONIC PLAN X X

M-501 MECHANICAL DETAILS X

M-502 MECHANICAL DETAILS X

M-503 MECHANICAL DETAILS X

M-505 MECHANICAL SCHEMATICS X

M-504 MECHANICAL DETAILS X

M-601 MECHANICAL SCHEDULES X

M-602 MECHANICAL SCHEDULES X

INDEX OF DRAWINGS

SHEET

NUMBER SHEET TITLE

RTA

SUBMITTAL

REVISION

REVISION

REVISION

GENERAL

GI001 COVER SHEET X

GI002 SHEET INDEX X X X X

GI003 GENERAL NOTES, ABBREVIATIONS X

GI004 LAYDOWN AREAS MAP X

GI005 JBLM TRUCK ROUTES MAP X

GI010 LIFE SAFETY NARRATIVE X

GI101 LIFE SAFETY PLAN FIRST FLOOR - OVERALL X

GI102 LIFE SAFETY PLAN FIRST FLOOR - AREA B X

GI103 LIFE SAFETY PLAN FIRST FLOOR - AREA A & C X

GI111 LIFE SAFETY PLAN SECOND FLOOR - OVERALL X

GI112 LIFE SAFETY PLAN SECOND FLOOR - AREA B X

GI113 LIFE SAFETY PLAN SECOND FLOOR - AREA A & C X

GI121 LIFE SAFETY PLAN THIRD FLOOR - OVERALL X

GI122 LIFE SAFETY PLAN THIRD FLOOR - AREA B X

GI123 LIFE SAFETY PLAN THIRD FLOOR - AREA A & C X

CIVIL

C-001 CIVIL GENERAL NOTES X

VF101 EXISTING CONDITIONS X

CD101 DEMOLITION PLAN X

CS101 SITE PLAN X X

CS102 SITE ARCHITECTURAL PLAN X X

CS103 AMENITIES LAYOUT PLAN X

CS104 AMENITIES GRADING PLAN X X

CS105 COURT LAYOUT PLAN X X X

CS501 SITE DETAILS X X

CS502 AMENITY DETAILS X X

CS503 SHELTER DETAILS X X

CS504 MISCELLANEOUS DETAILS X

CG101 GRADING AND DRAINAGE PLAN X

CG102 SIDEWALK GRADING PLAN X

CG501 STORM WATER DETAILS X

CU101 UTILITY PLAN X X

CU201 FIRE MAIN PLAN AND PROFILE X

CU202 SANITARY SEWER PLAN AND PROFILE X

CU501 SANITARY SEWER DETAILS X

CU502 SANITARY SEWER DETAILS X

CU503 WATERLINE DETAILS X

CU504 WATERLINE DETAILS X

LANDSCAPE

LP101 PLANTING PLAN X

LP102 PLANTING SCHEDULE X

STRUCTURAL

S-001 GENERAL NOTES X

S-002 GENERAL NOTES X

SB112 FIRST FLOOR PLAN AREA B X

SB113 FIRST FLOOR PLAN AREA A AND C X

SF112 SECOND/THIRD FLOOR AREA B PLAN X

SF113 SECOND/THIRD FLOOR AREA A AND C PLAN X

SF122 ATTIC PLAN AREA B X

SF123 ATTIC PLAN AREA A AND C X

SF132 ROOF PLAN AREA B X

SF133 ROOF PLAN AREA A AND C X

S-501 STRUCTURAL DETAILS X

S-502 STRUCTURAL DETAILS X

S-503 STRUCTURAL DETAILS X

ARCHITECTURAL

AD101 OVERALL FIRST FLOOR DEMOLITION PLAN X

AD102 FIRST FLOOR AREA-B DEMOLITION PLAN X X

AD103 FIRST FLOOR AREA-A AND C DEMOLITION PLAN X X

AD111 OVERALL SECOND FLOOR DEMOLITION PLAN X

AD112 SECOND FLOOR AREA-B DEMOLITION PLAN X X

AD113 SECOND FLOOR AREA-A AND C DEMOLITION PLAN X X

AD121 OVERALL THIRD FLOOR DEMOLITION PLAN X

AD122 THIRD FLOOR AREA-B DEMOLITION PLAN X X

AD123 THIRD FLOOR AREA-A AND C DEMOLITION PLAN X X

AD141 OVERALL ROOF DEMOLITION PLAN X

AE101 OVERALL FIRST FLOOR PLAN X

AE102 FIRST FLOOR AREA-B PLAN X

AE103 FIRST FLOOR AREA-A AND C PLAN X X

AE111 OVERALL SECOND FLOOR PLAN X

AE112 SECOND FLOOR AREA-B PLAN X X

AE113 SECOND FLOOR AREA-A AND C PLAN X

AE121 OVERALL THIRD FLOOR PLAN X

AE122 THIRD FLOOR AREA-B PLAN X X

AE123 THIRD FLOOR AREA-A AND C PLAN X

AE141 OVERALL ROOF PLAN X X

AE142 ROOF AREA-B PLAN X X

AE143 ROOF AREA-A AND C PLAN X X

AE151 OVERALL FIRST FLOOR REFLECTED CEILING PLAN X X

AE152 FIRST FLOOR AREA-B REFLECTED CEILING PLAN X X

AE161 OVERALL SECOND FLOOR REFLECTED CEILING PLAN X X

AE171 OVERALL THIRD FLOOR REFLECTED CEILING PLAN X X

AE201 AREA-A ELEVATIONS X

AE202 AREA-A ELEVATIONS X

AE203 AREA-B ELEVATIONS X

AE204 AREA-B ELEVATIONS X

AE205 AREA-C ELEVATIONS X

AE206 AREA-C ELEVATIONS X

AE301 BUILDING SECTIONS X

AE311 WALL SECTIONS X

AE401 LIVING UNIT ENLARGED FLOOR PLANS X X X

AE402 ENLARGED FLOOR PLANS X X

AE403 ENLARGED UNIT CEILING PLANS X X

AE501 WALL AND PLAN DETAILS X

AE510 ROOF DETAILS X X

AE511 ROOF DETAILS X X

AE520 CEILING DETAILS X

AE530 DOOR DETAILS X

AE531 DOOR AND OPENING DETAILS X X

AE540 WINDOW DETAILS X

AE601 PARTITION TYPES AND SCHEDULE X X

AE603 FIRST FLOOR DOOR SCHEDULE AND TYPES X

AE604 SECOND FLOOR DOOR SCHEDULE AND TYPES X

AE605 THIRD FLOOR DOOR SCHEDULE AND TYPES X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

EXISTING 8"

CMU WALL

(1)-#4 VERT IN FULLY

GROUTED CELLS

NOTE:

SHORING OF EXISTING CMU WALL DURING

CONSTRUCTION IS THE RESPONSIBILITY

OF THE GENERAL CONTRACTOR

A7

S-501

EXIST BOND

BEAM TO

REMAIN

EXIST VERT

REINFORCED

CELLS

EXIST HOLLOW

CORE SLAB

ALLOWABLE

PENETRATION

OR ANCHORAGE

AREA

FIELD VERIFY

4' - 0" PANEL WIDTH

1½" MIN EXIST PRESTRESSED

STRANDS TO REMAIN

UNDAMAGED

EXIST CORES

IN SLAB

NOTE:

THE EXISTING REINFORCING MUST BE

LOCATED BY NON-DESTRUCTIVE TESTING

METHODS PRIOR TO CUTTING/DEMOLISHING

OF ANY/ALL OPENINGS

S L A

B

/2

T O

P P

IN

G

F .V

EDGE OF

HOLLOW CORE

SLAB PANEL

ALLOWABLE PENETRATION

ANCHORAGE LOCATIONS

FORMING BY

CONTRACTOR

EXIST

OPENING

(24" MAX) (1)-#4 BAR IN EACH

CORE, EXTEND 6" PAST

OPENING, EACH END

4000 psi CONCRETE

FILL, REF GENERAL

NOTES

PROVIDE PAPER DAM IN

EXISTING CORES, TYP

TYP

1' - 0" MIN

PROVIDE PAPER

DAM IN EXISTING

CORES, TYP

EXISTING

TOPPING SLAB

NEW INFILL FLUSH W/

EXISTING TOPPING

EXISTING

HOLLOW

CORE SLAB

ZONE 2ZONE 1 ZONE 1

ZONE 1: (END ZONE) NEW PENETRATIONS ARE ALLOWED TO BE IN THIS AREA.

PENETRATIONS SHALL BE LIMITED TO 24" WIDE PERPENDICULAR TO THE SPAN.

LENGTH OF OPENING MAY BE UP TO 0.125 x L. EDGE OF ADDITIONAL OPENINGS MUST BE SPACED FURTHER THAN 0.5 x L PERPENDICULAR TO THE SPAN FROM

ANY NEW OR EXISTING EDGE OF OPENING, UNLESS APPROVED OR SHOWN

OTHERWISE. REFERENCE DETAIL C1/S-501 FOR REINFORCING.

ZONE 2: (MIDDLE ZONE) ANY PENETRATIONS IN THIS ZONE REQUIRE THE

EXISTING REINFORCING TENDONS TO BE LOCATED PRIOR TO DRILLING. IN NO

CASE SHALL THE PENETRATION CUT OR DAMAGE EXISTING REINFORCING. SEE

DETAIL .

EDGE OF SUPPORT

(IN MOST CASES FACE

OF EXIST. BRICK WALL)

EDGE OF

SUPPORT

0.125 L 0.125 L

OF HOLLOW CORE SLAB LENGTH

CLEAR SPAN (L)

/F4 S-501

W

ID

T H

H O

L L

O W

C O

R E

S L A

B

P A

N E

L

NOTE:

THE EXISTING REINFORCING MUST BE LOCATED BY

NON-DESTRUCTIVE TESTING METHODS PRIOR TO

CUTTING/DEMOLISHING OF ANY/ALL OPENINGS. NO

MORE THAN 2 EXISTING STRANDS CAN BE CUT.

L6x6x3/8 x WIDTH

OF OPNG

PROVIDE PAPER DAM

IN EXISTING CORES

L6x6x3/8, EXTEND LENGTH

8" PAST EDGES OF OPNG

3/16 3-12

GRIND DOWN EXIST TOPPING SLAB

AT NEW ANGLE BEARING TO HAVE

ANGLE FLUSH W/ TOP OF FINISH

EXIST

TOPPING SLAB

1' - 0"

EXIST HOLLOW

CORE SLAB

4000 psi CONCRETE FILL, REF GENERAL NOTES

A-A

A

A

TYP

8" MIN

PLAN

B B EXISTING HOLLOW

CORE SLAB AND

TOPPING SLAB BEYOND

EXIST MASONRY

WALL

1' - 2" MAX. 1' - 2" MAX.

ANGLE HEADER

ACROSS OPNG,

REF.

DO NOT DAMAGE

EXIST PRECAST

HOLLOW CORE

SLAB BEYOND

2' - 4" MAX.

EXIST MASONRY

WALL

EXIST SLAB/C1 S-503

EDGE OF

SUPPORT

CONCRETE SLAB (THICKNESS

TO MATCH EXIST., 4" MIN.), REINF

W/ #4 @ 12"O.C. (CENTERED IN

SLAB) EACH WAY

OVER PREPARED SUBGRADE

LEAN CONCRETE OR

COMPACTED

GRANULAR FILL AS

REQ'D

#4 DWL STAGGERED @

24"O.C. ALONG SLAB EDGE,

DRILL & ADHERE INTO

EXIST. (4" MIN. EMBED)

LOCATE CENTER OF SLAB

NOTE:

SLAB JOINTS TO

MATCH EXIST.

NOTE:

OVERCUTTING IS NOT

ALLOWED AT CORNERS

WHEN REMOVING EXISTING

CONCRETE SLAB

AS NEEDED FOR

CONSTRUCTION

VAPOR BARRIER,

REF ARCH

MASONRY WALL

BEYOND

A

F F

(F .V

EXIST HOLLOW

CORE SLAB

EXIST CONCRETE

TOPPING SLAB

(2) EXIST #5 BARS

NOTE:

MAXIMUM OPENING WIDTH = 4'-0"

EXIST MASONRY

WALL

NOTE:

CUT BACK EXISTING

REINFORCING EXPOSED BY

DEMOLITION; FLUSH TO SLAB.

CONTRACTOR SHALL PAINT OR

GALVANIZE THE EXPOSED BARS

WITH A MATERIAL THAT IS

COMPATIBLE WITH ANY

MATERIAL THE COATING WILL

BE EXPOSED TO.

EXIST HOLLOW

CORE SLAB

EXIST TOPPING SLAB

1' - 0" 2' - 0" 1' - 0"

CARBON FIBER FABRIC

STRIP, REF PLANS FOR

ADDITIONAL INFORMATION EXIST

MASONRY

WALL

APPLY CARBON FABRIC STRIPS OR EQUIVALENT TO UNDERSIDE OF EXISTING

PRECAST HOLLOW CORE SLAB AT 24" O.C. CARBON FABRIC STRIPS SHALL BE

12" WIDE, 0.04" THICK, AND CONTINUOUS WITH A MINIMUM DESIGN TENSILE

STRENGTH OF 128,000 PSI, AND A DESIGN TENSILE MODULUS OF 14,200 KSI.

CARBON FIBER AND CONCRETE SURFACES SHALL BE PREPARED AND

APPLIED PER MANUFACTURER'S RECOMMENDATIONS. PRODUCTS MUST HAVE

AN UP-TO-DATE 3RD PARTY TEST REPORT, SUCH AS ICC-ESR.

SEE SHEET S-001 FOR GENERAL STRUCTURAL NOTES AND ADDITIONAL

INFORMATION.

L6x6x3/8 x WIDTH

OF OPNG

L6x6x3/8, EXTEND

HORZ. LEG PAST

EDGE OF OPNG

3/16

GRIND DOWN EXIST

TOPPING SLAB AT NEW

ANGLE BEARING TO

HAVE ANGLE FLUSH W/

TOP OF FINISH

EXIST HOLLOW

CORE SLAB

B-B

3/4" MAX

8"

1/2" CUT RADIUS

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

P R

O F

E S

S

IO

N A

L E

N G

IN

E

E R

IN

G

C O

N S

U L T

A N

T S

P

.A

S

T O

P E

K A

W

IC

H

IT

A K

S

S-501

S T

R U

C T

U R

A L D

E T

A

IL

S

J O

IN

T

B A

S E

L E

W

IS

-M C

C H

O R

D W

A

S E

A T

T L E

D

IS

T R

IC

T

E

M

A R

G

IN

A L W

A Y

S O

U T

H B

L D

G

S E

A T

T L E

W

A

-2

C M

Y R

T L E

J R

O H

L E

D E

R

C P

R Z

Y G

O D

A

P R

A D

L E

Y

A

U G

U S

T

T B

D

T B

D

REVISION 01, AMENDMENT

R E

P A

IR

B

U

IL

D

IN

G

D E

S

IG

N C

O N

S T

R U

C T

O

IN

P K

G N

O C

E C

E

3/4" = 1'-0"F1

MASONRY JAMB DETAIL

1" = 1'-0"F4

HOLLOW CORE SLAB PENETRATION AND ANCHORAGE

1" = 1'-0"F7

HOLLOW CORE REPAIR DETAIL

1/2" = 1'-0"C5

NEW OPENING ZONES PLAN

1" = 1'-0"C1

FLOOR OPENING EDGE DETAILS

3/4" = 1'-0"C8

NEW FLOOR OPENING SECTION

3/4" = 1'-0"A1

NEW FLOOR OPENING SECTION

1" = 1'-0"A4

SLAB-ON-GRADE REPAIR DETAIL

3/4" = 1'-0"A7

NEW WALL OPENING SECTION

3/4" = 1'-0"A8

STRIP REINFORCING ON SLAB

R

E V

IS

IO

N

A

M E

N D

M E

N T

/0

/2

NOTE:

ALL EXPOSED SURFACES MUST HAVE

A SMOOTH FINISH. FILL ANY VOIDS.

FORM SHALL BE REMOVED AND ANY

TEMPORARY ANCHOR HOLES SHALL

BE PATCHED.

09/09/2021

C1 C2 C3 C4

C3.5C2.5

A1

A2

A2.5

B1

B2

B4

B5

B3

7 7

7 7 7

6 6

6 6

6 6

1 4 2 1

77 7

1 11

6 6

1 1

1 1 11

/A4 AD103

/A4 AD103

/A1 AD103 /A1 AD103

14 14 14 14 14 14

14 14 14

A

B C

CMU PARTITION TO BE REMOVED,

REFERENCE KEYNOTE.

DOOR, FRAME AND HARDWARE

TO BE REMOVED

WINDOW TO BE REMOVED

EXISTING CMU PARTITION TO

REMAIN

DEMOLITION LEGEND

*REFER TO GENERAL DEMOLITION NOTES ON

OVERALL DEMOLITION PLANS*

EXISTING LADDER TO BE REMOVED

1 DEMOLISH EXISTING DOOR AND FRAME.

PREPARE OPENING FOR NEW DOOR

AND FRAME.

2 DEMOLISH EXISTING DOOR AND

FRAME AND PREPARE OPENING

FOR INFILL

3 DEMOLISH EXISTING PARTITION,

AND ANY DOORS NOT KEYNOTED.

4 DEMOLISH EXISTING PLUMBING

FIXTURES, REF., MECH. DEMOLITION

DWGS

5 DEMOLISH EXISTING WINDOW AND

PREPARE OPENING FOR NEW

WINDOW ASSEMBLY

6 DEMOLISH EXISTING BUILT-IN

MILLWORK

7 DEMOLISH EXISTING MECHANICAL

UNITS. REF., MECH. DEMOLITION

DWGS

8 DEMOLISH EXISTING THROUGH

WALL MECHANICAL LOUVER.

PREPARE OPENING TO BE INFILLED.

REF. MECH. DEMOLITION DWGS

9 DEMOLISH PORTION OF EXISTING

SHEAR WALL. REF. STRUCT DWGS

10 DEMOLISH EXISTING SEISMIC JOINT

SEALANTS AND GASKETS, PREPARE

AREA FOR NEW GASKET AND SEALANT

INSTALLATION.

11 COORDINATE MECHANICAL, PLUMBING,

ELECTRICAL, AND FIRE PROTECTION

EQUIPMENT DEMOLITION, WITH

ASSOCIATED DISCIPLINE DEMOLITION

PLANS FOR ROOM.

12 DEMOLISH EXISTING STOREFRONT

WINDOW SYSTEM AND DOORS.

PREPARE SURFACES FOR NEW

CURTAIN WALL SYSTEM.

13 DEMOLISH EXISTING WINDOW AND

THROUGH WALL VENT BELOW.

FURTHER DEMOLITION BELOW

WINDOW SILL TO ACCOMODATE NEW

CONSTRUCTION DOOR OPENING WILL

BE REQUIRED.

DEMOLITION KEY NOTES

14 DEMOLISH EXISTING FLOOR SLAB AS

REQUIRED FOR UTILITY REMOVAL AND

FOR THE INSTALLATION OF NEW

UTILITIES, REF. STRUCTURAL,

PLUMBING, AND ELECTRICAL DWGS.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

AD102

F

IR

S T

F L O

O R

A R

E A

-B D

E M

O L

IT

IO

N

P L A

N

J O

IN

T

B A

S E

L E

W

IS

-M C

C H

O R

D W

A

S E

A T

T L E

D

IS

T R

IC

T

E

M

A R

G

IN

A L W

A Y

S O

U T

H B

L D

G

S E

A T

T L E

W

A

-2

Y A

E G

E R

A R

C H

IT

E

C T

U R

E P

E N

R O

S E

L A

N E

S

U

IT

E

L E

N E

X A

K

S

K C

O U

G H

L

IN

K C

O U

G H

L

IN

C P

R Z

Y G

O D

A

M T

U R

N E

R

S

E P

T E

M B

E R

T B

D

T B

D

REVISION 04, AMENDMENT

R E

P A

IR

B

U

IL

D

IN

G

D E

S

IG

N C

O N

S T

R U

C T

IO

N

P K

G N

O C

E C

E

1/8" = 1'-0"A1

FIRST FLOOR AREA-B DEMOLITION PLAN 0 4' 8' 16'

SCALE: 1/8" = 1'

PLAN NORTH

R

E V

IS

IO

N

A

M E

N D

M E

N T

/0

/2

A3

A4

A5

A6

A7

A8

A2.5

A3.5

A4.5

A5.5

A6.5

A7.5

6 1

6 2

6 1

/A1 AD102 /A1 AD102

C4 C5 C6 C7 C8

C4.5 C5.5 C6.5 C7.5

6 6

6 6

6 6

6 6

4 4

1 2 1

1 2 1 1

7 77 77 77

6 6

6 6

6 6

9 9

/A1 AD102

/A1 AD102

14 14

14 14

14 14 14 14 14 14

14 14 14 14 14

A

B C

CMU PARTITION TO BE REMOVED,

REFERENCE KEYNOTE.

DOOR, FRAME AND HARDWARE

TO BE REMOVED

WINDOW TO BE REMOVED

EXISTING CMU PARTITION TO

REMAIN

DEMOLITION LEGEND

*REFER TO GENERAL DEMOLITION NOTES ON

OVERALL DEMOLITION PLANS*

EXISTING LADDER TO BE REMOVED

1 DEMOLISH EXISTING DOOR AND FRAME.

PREPARE OPENING FOR NEW DOOR

AND FRAME.

2 DEMOLISH EXISTING DOOR AND

FRAME AND PREPARE OPENING

FOR INFILL

3 DEMOLISH EXISTING PARTITION,

AND ANY DOORS NOT KEYNOTED.

4 DEMOLISH EXISTING PLUMBING

FIXTURES, REF., MECH. DEMOLITION

DWGS

5 DEMOLISH EXISTING WINDOW AND

PREPARE OPENING FOR NEW

WINDOW ASSEMBLY

6 DEMOLISH EXISTING BUILT-IN

MILLWORK

7 DEMOLISH EXISTING MECHANICAL

UNITS. REF., MECH. DEMOLITION

DWGS

8 DEMOLISH EXISTING THROUGH

WALL MECHANICAL LOUVER.

PREPARE OPENING TO BE INFILLED.

REF. MECH. DEMOLITION DWGS

9 DEMOLISH PORTION OF EXISTING

SHEAR WALL. REF. STRUCT DWGS

10 DEMOLISH EXISTING SEISMIC JOINT

SEALANTS AND GASKETS, PREPARE

AREA FOR NEW GASKET AND SEALANT

INSTALLATION.

11 COORDINATE MECHANICAL, PLUMBING,

ELECTRICAL, AND FIRE PROTECTION

EQUIPMENT DEMOLITION, WITH

ASSOCIATED DISCIPLINE DEMOLITION

PLANS FOR ROOM.

12 DEMOLISH EXISTING STOREFRONT

WINDOW SYSTEM AND DOORS.

PREPARE SURFACES FOR NEW

CURTAIN WALL SYSTEM.

13 DEMOLISH EXISTING WINDOW AND

THROUGH WALL VENT BELOW.

FURTHER DEMOLITION BELOW

WINDOW SILL TO ACCOMODATE NEW

CONSTRUCTION DOOR OPENING WILL

BE REQUIRED.

DEMOLITION KEY NOTES

14 DEMOLISH EXISTING FLOOR SLAB AS

REQUIRED FOR UTILITY REMOVAL AND

FOR THE INSTALLATION OF NEW

UTILITIES, REF. STRUCTURAL,

PLUMBING, AND ELECTRICAL DWGS.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

AD103

F

IR

S T

F L O

O R

A R

E A

-A A

N D

C D

E M

O L

IT

IO

N

P L A

N

J O

IN

T

B A

S E

L E

W

IS

-M C

C H

O R

D W

A

S E

A T

T L E

D

IS

T R

IC

T

E

M

A R

G

IN

A L W

A Y

S O

U T

H B

L D

G

S E

A T

T L E

W

A

-2

Y A

E G

E R

A R

C H

IT

E

C T

U R

E P

E N

R O

S E

L A

N E

S

U

IT

E

L E

N E

X A

K

S

K C

O U

G H

L

IN

K C

O U

G H

L

IN

C P

R Z

Y G

O D

A

M T

U R

N E

R

S

E P

T E

M B

E R

T B

D

T B

D

REVISION 04, AMENDMENT

R E

P A

IR

B

U

IL

D

IN

G

D E

S

IG

N C

O N

S T

R U

C T

IO

N

P K

G N

O C

E C

E

1/8" = 1'-0"A1

FIRST FLOOR AREA-A DEMOLITION PLAN

1/8" = 1'-0"A4

FIRST FLOOR AREA-B DEMOLITION PLAN

0 4' 8' 16'

SCALE: 1/8" = 1'

PLAN NORTH

R

E V

IS

IO

N

A

M E

N D

M E

N T

/0

/2

A1

A2

A2.5

B1

B2

B4

B5

B3

7 7

7 7 7

6 6

6 6

6 6

77 7

6 6

8 1

6 6

/A1 AD113 /A1 AD113

/A4 AD113

/A4 AD113

1 12

A

B C

CMU PARTITION TO BE REMOVED,

REFERENCE KEYNOTE.

DOOR, FRAME AND HARDWARE

TO BE REMOVED

WINDOW TO BE REMOVED

EXISTING CMU PARTITION TO

REMAIN

DEMOLITION LEGEND

*REFER TO GENERAL DEMOLITION NOTES ON

OVERALL DEMOLITION PLANS*

EXISTING LADDER TO BE REMOVED

1 DEMOLISH EXISTING DOOR AND FRAME.

PREPARE OPENING FOR NEW DOOR

AND FRAME.

2 DEMOLISH EXISTING DOOR AND

FRAME AND PREPARE OPENING

FOR INFILL

3 DEMOLISH EXISTING PARTITION,

AND ANY DOORS NOT KEYNOTED.

4 DEMOLISH EXISTING PLUMBING

FIXTURES, REF., MECH. DEMOLITION

DWGS

5 DEMOLISH EXISTING WINDOW AND

PREPARE OPENING FOR NEW

WINDOW ASSEMBLY

6 DEMOLISH EXISTING BUILT-IN

MILLWORK

7 DEMOLISH EXISTING MECHANICAL

UNITS. REF., MECH. DEMOLITION

DWGS

8 DEMOLISH EXISTING THROUGH

WALL MECHANICAL LOUVER.

PREPARE OPENING TO BE INFILLED.

REF. MECH. DEMOLITION DWGS

9 DEMOLISH PORTION OF EXISTING

SHEAR WALL. REF. STRUCT DWGS

10 DEMOLISH EXISTING SEISMIC JOINT

SEALANTS AND GASKETS, PREPARE

AREA FOR NEW GASKET AND SEALANT

INSTALLATION.

11 COORDINATE MECHANICAL, PLUMBING,

ELECTRICAL, AND FIRE PROTECTION

EQUIPMENT DEMOLITION, WITH

ASSOCIATED DISCIPLINE DEMOLITION

PLANS FOR ROOM.

12 DEMOLISH EXISTING STOREFRONT

WINDOW SYSTEM AND DOORS.

PREPARE SURFACES FOR NEW

CURTAIN WALL SYSTEM.

13 DEMOLISH EXISTING WINDOW AND

THROUGH WALL VENT BELOW.

FURTHER DEMOLITION BELOW

WINDOW SILL TO ACCOMODATE NEW

CONSTRUCTION DOOR OPENING WILL

BE REQUIRED.

DEMOLITION KEY NOTES

14 DEMOLISH EXISTING FLOOR SLAB AS

REQUIRED FOR UTILITY REMOVAL AND

FOR THE INSTALLATION OF NEW

UTILITIES, REF. STRUCTURAL,

PLUMBING, AND ELECTRICAL DWGS.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

AD112

S E

C O

N D

F L O

O R

A R

E A

-B D

E M

O L

IT

IO

N

P L A

N

J O

IN

T

B A

S E

L E

W

IS

-M C

C H

O R

D W

A

S E

A T

T L E

D

IS

T R

IC

T

E

M

A R

G

IN

A L W

A Y

S O

U T

H B

L D

G

S E

A T

T L E

W

A

-2

Y A

E G

E R

A R

C H

IT

E

C T

U R

E P

E N

R O

S E

L A

N E

S

U

IT

E

L E

N E

X A

K

S

K C

O U

G H

L

IN

K C

O U

G H

L

IN

C P

R Z

Y G

O D

A

M T

U R

N E

R

S

E P

T E

M B

E R

T B

D

T B

D

REVISION 04, AMENDMENT

R E

P A

IR

B

U

IL

D

IN

G

D E

S

IG

N C

O N

S T

R U

C T

IO

N

P K

G N

O C

E C

E

1/8" = 1'-0"A1

SECOND FLOOR AREA-B DEMOLITION PLAN

0 4' 8' 16'

SCALE: 1/8" = 1'

PLAN NORTH

R

E V

IS

IO

N

A

M E

N D

M E

N T

/0

/2

A5

A6

A7

A8

A2.5

A3.5

A4.5

A5.5

A6.5

A7.5

6 1

6 2

6 1

/A1 AD112 /A1 AD112

C4 C5 C6 C7 C8

C4.5 C5.5 C6.5 C7.5

6 6

6 6

6 6

6 6

4 4

1 2 1 1

1 2 1 1

7 77 77 77

6 6

6 6

6 6

9 9

/A1 AD112

/A1 AD112

A

B C

CMU PARTITION TO BE REMOVED,

REFERENCE KEYNOTE.

DOOR, FRAME AND HARDWARE

TO BE REMOVED

WINDOW TO BE REMOVED

EXISTING CMU PARTITION TO

REMAIN

DEMOLITION LEGEND

*REFER TO GENERAL DEMOLITION NOTES ON

OVERALL DEMOLITION PLANS*

EXISTING LADDER TO BE REMOVED

1 DEMOLISH EXISTING DOOR AND FRAME.

PREPARE OPENING FOR NEW DOOR

AND FRAME.

2 DEMOLISH EXISTING DOOR AND

FRAME AND PREPARE OPENING

FOR INFILL

3 DEMOLISH EXISTING PARTITION,

AND ANY DOORS NOT KEYNOTED.

4 DEMOLISH EXISTING PLUMBING

FIXTURES, REF., MECH. DEMOLITION

DWGS

5 DEMOLISH EXISTING WINDOW AND

PREPARE OPENING FOR NEW

WINDOW ASSEMBLY

6 DEMOLISH EXISTING BUILT-IN

MILLWORK

7 DEMOLISH EXISTING MECHANICAL

UNITS. REF., MECH. DEMOLITION

DWGS

8 DEMOLISH EXISTING THROUGH

WALL MECHANICAL LOUVER.

PREPARE OPENING TO BE INFILLED.

REF. MECH. DEMOLITION DWGS

9 DEMOLISH PORTION OF EXISTING

SHEAR WALL. REF. STRUCT DWGS

10 DEMOLISH EXISTING SEISMIC JOINT

SEALANTS AND GASKETS, PREPARE

AREA FOR NEW GASKET AND SEALANT

INSTALLATION.

11 COORDINATE MECHANICAL, PLUMBING,

ELECTRICAL, AND FIRE PROTECTION

EQUIPMENT DEMOLITION, WITH

ASSOCIATED DISCIPLINE DEMOLITION

PLANS FOR ROOM.

12 DEMOLISH EXISTING STOREFRONT

WINDOW SYSTEM AND DOORS.

PREPARE SURFACES FOR NEW

CURTAIN WALL SYSTEM.

13 DEMOLISH EXISTING WINDOW AND

THROUGH WALL VENT BELOW.

FURTHER DEMOLITION BELOW

WINDOW SILL TO ACCOMODATE NEW

CONSTRUCTION DOOR OPENING WILL

BE REQUIRED.

DEMOLITION KEY NOTES

14 DEMOLISH EXISTING FLOOR SLAB AS

REQUIRED FOR UTILITY REMOVAL AND

FOR THE INSTALLATION OF NEW

UTILITIES, REF. STRUCTURAL,

PLUMBING, AND ELECTRICAL DWGS.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

AD113

S E

C O

N D

F L O

O R

A R

E A

-A A

N D

C D

E M

O L

IT

IO

N

P L A

N

J O

IN

T

B A

S E

L E

W

IS

-M C

C H

O R

D W

A

S E

A T

T L E

D

IS

T R

IC

T

E

M

A R

G

IN

A L W

A Y

S O

U T

H B

L D

G

S E

A T

T L E

W

A

-2

Y A

E G

E R

A R

C H

IT

E

C T

U R

E P

E N

R O

S E

L A

N E

S

U

IT

E

L E

N E

X A

K

S

K C

O U

G H

L

IN

K C

O U

G H

L

IN

C P

R Z

Y G

O D

A

M T

U R

N E

R

S

E P

T E

M B

E R

T B

D

T B

D

REVISION 04, AMENDMENT

R E

P A

IR

B

U

IL

D

IN

G

D E

S

IG

N C

O N

S T

R U

C T

IO

N

P K

G N

O C

E C

E

1/8" = 1'-0"A1

SECOND FLOOR AREA-A DEMOLITION PLAN

1/8" = 1'-0"A4

SECOND FLOOR AREA-C DEMOLITION PLAN

0 4' 8' 16'

SCALE: 1/8" = 1'

PLAN NORTH

R

E V

IS

IO

N

A

M E

N D

M E

N T

/0

/2

A1

A2

A2.5

B1

B2

B4

B5

B3

7 7

7 7 7

6 6

6 6

6 6

4 2

77 7

1 11

6 6

8 1

6 6

3'

1/

2"

/A4 AD123

/A4 AD123

/A1 AD123 /A1 AD123

A

B C

CMU PARTITION TO BE REMOVED,

REFERENCE KEYNOTE.

DOOR, FRAME AND HARDWARE

TO BE REMOVED

WINDOW TO BE REMOVED

EXISTING CMU PARTITION TO

REMAIN

DEMOLITION LEGEND

*REFER TO GENERAL DEMOLITION NOTES ON

OVERALL DEMOLITION PLANS*

EXISTING LADDER TO BE REMOVED

1 DEMOLISH EXISTING DOOR AND FRAME.

PREPARE OPENING FOR NEW DOOR

AND FRAME.

2 DEMOLISH EXISTING DOOR AND

FRAME AND PREPARE OPENING

FOR INFILL

3 DEMOLISH EXISTING PARTITION,

AND ANY DOORS NOT KEYNOTED.

4 DEMOLISH EXISTING PLUMBING

FIXTURES, REF., MECH. DEMOLITION

DWGS

5 DEMOLISH EXISTING WINDOW AND

PREPARE OPENING FOR NEW

WINDOW ASSEMBLY

6 DEMOLISH EXISTING BUILT-IN

MILLWORK

7 DEMOLISH EXISTING MECHANICAL

UNITS. REF., MECH. DEMOLITION

DWGS

8 DEMOLISH EXISTING THROUGH

WALL MECHANICAL LOUVER.

PREPARE OPENING TO BE INFILLED.

REF. MECH. DEMOLITION DWGS

9 DEMOLISH PORTION OF EXISTING

SHEAR WALL. REF. STRUCT DWGS

10 DEMOLISH EXISTING SEISMIC JOINT

SEALANTS AND GASKETS, PREPARE

AREA FOR NEW GASKET AND SEALANT

INSTALLATION.

11 COORDINATE MECHANICAL, PLUMBING,

ELECTRICAL, AND FIRE PROTECTION

EQUIPMENT DEMOLITION, WITH

ASSOCIATED DISCIPLINE DEMOLITION

PLANS FOR ROOM.

12 DEMOLISH EXISTING STOREFRONT

WINDOW SYSTEM AND DOORS.

PREPARE SURFACES FOR NEW

CURTAIN WALL SYSTEM.

13 DEMOLISH EXISTING WINDOW AND

THROUGH WALL VENT BELOW.

FURTHER DEMOLITION BELOW

WINDOW SILL TO ACCOMODATE NEW

CONSTRUCTION DOOR OPENING WILL

BE REQUIRED.

DEMOLITION KEY NOTES

14 DEMOLISH EXISTING FLOOR SLAB AS

REQUIRED FOR UTILITY REMOVAL AND

FOR THE INSTALLATION OF NEW

UTILITIES, REF. STRUCTURAL,

PLUMBING, AND ELECTRICAL DWGS.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

AD122

T H

IR

D

F L O

O R

A R

E A

-B D

E M

O L

IT

IO

N

P L A

N

J O

IN

T

B A

S E

L E

W

IS

-M C

C H

O R

D W

A

S E

A T

T L E

D

IS

T R

IC

T

E

M

A R

G

IN

A L W

A Y

S O

U T

H B

L D

G

S E

A T

T L E

W

A

-2

Y A

E G

E R

A R

C H

IT

E

C T

U R

E P

E N

R O

S E

L A

N E

S

U

IT

E

L E

N E

X A

K

S

K C

O U

G H

L

IN

K C

O U

G H

L

IN

C P

R Z

Y G

O D

A

M T

U R

N E

R

S

E P

T E

M B

E R

T B

D

T B

D

REVISION 04, AMENDMENT

R E

P A

IR

B

U

IL

D

IN

G

D E

S

IG

N C

O N

S T

R U

C T

IO

N

P K

G N

O C

E C

E

1/8" = 1'-0"A1

THIRD FLOOR AREA-B DEMOLITION PLAN

0 4' 8' 16'

SCALE: 1/8" = 1'

PLAN NORTH

R

E V

IS

IO

N

A

M E

N D

M E

N T

/0

/2

A5

A6

A7

A8

A2.5

A3.5

A4.5

A5.5

A6.5

A7.5

6 1

6 1

6 2

6 1

6 1

/A1 AD122 /A1 AD122

C4 C5 C6 C7 C8

C4.5 C5.5 C6.5 C7.5

6 6

6 6

6 6

6 6

4 4

1 2 1

1 2 1 1

7 77 77 77

6 6

6 6

6 6

9 9

1 1

/A1 AD122

/A1 AD122

A

B C

CMU PARTITION TO BE REMOVED,

REFERENCE KEYNOTE.

DOOR, FRAME AND HARDWARE

TO BE REMOVED

WINDOW TO BE REMOVED

EXISTING CMU PARTITION TO

REMAIN

DEMOLITION LEGEND

*REFER TO GENERAL DEMOLITION NOTES ON

OVERALL DEMOLITION PLANS*

EXISTING LADDER TO BE REMOVED

1 DEMOLISH EXISTING DOOR AND FRAME.

PREPARE OPENING FOR NEW DOOR

AND FRAME.

2 DEMOLISH EXISTING DOOR AND

FRAME AND PREPARE OPENING

FOR INFILL

3 DEMOLISH EXISTING PARTITION,

AND ANY DOORS NOT KEYNOTED.

4 DEMOLISH EXISTING PLUMBING

FIXTURES, REF., MECH. DEMOLITION

DWGS

5 DEMOLISH EXISTING WINDOW AND

PREPARE OPENING FOR NEW

WINDOW ASSEMBLY

6 DEMOLISH EXISTING BUILT-IN

MILLWORK

7 DEMOLISH EXISTING MECHANICAL

UNITS. REF., MECH. DEMOLITION

DWGS

8 DEMOLISH EXISTING THROUGH

WALL MECHANICAL LOUVER.

PREPARE OPENING TO BE INFILLED.

REF. MECH. DEMOLITION DWGS

9 DEMOLISH PORTION OF EXISTING

SHEAR WALL. REF. STRUCT DWGS

10 DEMOLISH EXISTING SEISMIC JOINT

SEALANTS AND GASKETS, PREPARE

AREA FOR NEW GASKET AND SEALANT

INSTALLATION.

11 COORDINATE MECHANICAL, PLUMBING,

ELECTRICAL, AND FIRE PROTECTION

EQUIPMENT DEMOLITION, WITH

ASSOCIATED DISCIPLINE DEMOLITION

PLANS FOR ROOM.

12 DEMOLISH EXISTING STOREFRONT

WINDOW SYSTEM AND DOORS.

PREPARE SURFACES FOR NEW

CURTAIN WALL SYSTEM.

13 DEMOLISH EXISTING WINDOW AND

THROUGH WALL VENT BELOW.

FURTHER DEMOLITION BELOW

WINDOW SILL TO ACCOMODATE NEW

CONSTRUCTION DOOR OPENING WILL

BE REQUIRED.

DEMOLITION KEY NOTES

14 DEMOLISH EXISTING FLOOR SLAB AS

REQUIRED FOR UTILITY REMOVAL AND

FOR THE INSTALLATION OF NEW

UTILITIES, REF. STRUCTURAL,

PLUMBING, AND ELECTRICAL DWGS.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

AD123

T H

IR

D

F L O

O R

A R

E A

-A A

N D

C D

E M

O L

IT

IO

N

P L A

N

J O

IN

T

B A

S E

L E

W

IS

-M C

C H

O R

D W

A

S E

A T

T L E

D

IS

T R

IC

T

E

M

A R

G

IN

A L W

A Y

S O

U T

H B

L D

G

S E

A T

T L E

W

A

-2

Y A

E G

E R

A R

C H

IT

E

C T

U R

E P

E N

R O

S E

L A

N E

S

U

IT

E

L E

N E

X A

K

S

K C

O U

G H

L

IN

K C

O U

G H

L

IN

C P

R Z

Y G

O D

A

M T

U R

N E

R

S

E P

T E

M B

E R

T B

D

T B

D

REVISION 04, AMENDMENT

R E

P A

IR

B

U

IL

D

IN

G

D E

S

IG

N C

O N

S T

R U

C T

IO

N

P K

G N

O C

E C

E

1/8" = 1'-0"A1

THIRD FLOOR AREA-A DEMOLITION PLAN

1/8" = 1'-0"A4

THIRD FLOOR AREA-C DEMOLITION PLAN

0 4' 8' 16'

SCALE: 1/8" = 1'

PLAN NORTH

R

E V

IS

IO

N

A

M E

N D

M E

N T

/0

/2

UP

C3.5C2.5

A1

A2

A2.5

B1

B2

B4

B5

B3

A E203

A

A E203

E

MECH

FIRE ALARM

NEC COMM

SWITCHGEAR

JAN

AE401

E1

MAIL ACCESS

ROOM

UNISEX

LOBBY

CQ

102A

MUDROOM

152A

MUDROOM

FOYER

FIRE RISER /

UTILITY

NEC COMM

AE206

E6

AE

4A1

A E204

A

AE202

E6

E5

AE301

AE

4E1

AE

4E3

A E204

C

A E204

E

AE204

A6

A E

A

C1

AE301

AAA

A A AAAA

A

A

A

A

A

4A

103VESTIBULE

C A

C B

2B

2A

100A

STAIR C

C1

152B

A

A

A

A

162 161

163164

B101A B101B

CORRIDOR

CORRIDOR

STAIR B

B1

C

C

108X

X

X

Z

Y

Z

Z

Z

Z

Z

Y

110X

X

X

X

X Z

Z

Z

Y

113X

X

X

161Y

164XX

X

161XX

164Y164Z

164ZZ

166ZZ 169XX

X

4B

STORAGE

104B

UTILITY

104A

31 1 1

AE402

E1

UNIT

UNIT

UNIT

UNIT

UNIT

IN401

A1

IN401

A3

IN401

A6

IN401

A8

AE

7E7

/A1 AE103/A1 AE103

/A4 AE103

/A4 AE103

FIRE ALARM

153A

6'

1/

2"

10' - 6"

5' - 1"

153A

10 10

IN401

F9

L2

L4

AE607

E9

L3

AE401

E6

AE401

E1

6"

/2

15' - 0"

1' - 2"

2' - 6"

2'

1/

2"

OPP

OPP

1' - 8"

A

B C

1 INFILL EXISTING OPENING.

REF. STRUCT

2 INFILL EXISTING FLOOR VOIDS.

REF. STRUCT

3 WATER FOUNTAIN WITH BOTTLE

FILLER, REF. MECH.

4 PAINT EXISTING HANDRAILS, REF.

INTERIOR FINISH SCHEDULE.

FLOOR PLAN KEY NOTES

5 COMMERCIAL WASHER. REF. MECH.

FOR ROUGH-IN. REF. FF&E FOR CUT

SHEETS.

6 COMMERCIAL DRYER. REF. MECH.

FOR ROUGH-IN. REF. FF&E FOR CUT

SHEETS.

7 UTILITY SINK. REF. MECH. FOR

ROUGH-IN.

8 SEISMIC JOINT SEALANT, GASKET,

AND COVER, REF. D3/AE501, D6/AE501,

AND B8/AE520 FOR DETAILS

9 ATTIC ACCESS LADDER AND HATCH,

REF. A6/AE511

10 SPLASHBLOCK AT EVERY DOWNSPOUT

11 CASED OPENING, REF. AE531

12 BOOTWASH AND SHELTER, REF. CIVIL

13 BICYCLE RACK AND SHELTER,

REF. CIVIL

*REFER TO GENERAL FLOOR PLAN NOTES ON

OVERALL FLOOR PLANS*

*REFER TO SHEET AE601 FOR PARTITION TYPES*

*REFER TO SHEETS AE603-AE606 FOR DOOR

SCHEDULES AND TYPES*

*REFER TO SHEET AE607 FOR WINDOW

SCHEDULE AND TYPES*

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

AE102

F

IR

S T

F L O

O R

A R

E A

-B P

L A

N

J O

IN

T

B A

S E

L E

W

IS

-M C

C H

O R

D W

A

S E

A T

T L E

D

IS

T R

IC

T

E

M

A R

G

IN

A L W

A Y

S O

U T

H B

L D

G

S E

A T

T L E

W

A

-2

Y A

E G

E R

A R

C H

IT

E

C T

U R

E P

E N

R O

S E

L A

N E

S

U

IT

E

L E

N E

X A

K

S

K C

O U

G H

L

IN

K C

O U

G H

L

IN

C P

R Z

Y G

O D

A

M T

U R

N E

R

S

E P

T E

M B

E R

T B

D

T B

D

REVISION 04, AMENDMENT

R E

P A

IR

B

U

IL

D

IN

G

D E

S

IG

N C

O N

S T

R U

C T

IO

N

P K

G N

O C

E C

E

0 4' 8' 16'

SCALE: 1/8" = 1'

PLAN NORTH

1/8" = 1'-0"A1

FIRST FLOOR AREA-B PLAN

R

E V

IS

IO

N

A

M E

N D

M E

N T

/0

/2

140 SF

SLEEPING

140 SF

SLEEPING

275 SF

UNIT

40 SF

CLOSET

36 SF

MECH.

23 SF

HALL/LAVATORY

34 SF

BATHROOM

R .O

10 12

/8

7' - 5 3/8"

4' - 10 9/16"

/2

/8

12' - 3 15/16"

/8

/2

IN401

F1

F4

F7

CS

CS

LIVING/KITCHEN

39 SF

CLOSET

AE402

A1

D3

IN501

MC

11' - 9 1/2"

8' - 11 1/2"

AE501

F1

/4

2' - 8"

138 SF

SLEEPING

227 SF

UNIT

40 SF

CLOSET

36 SF

MECH.

43 SF

BATHROOM

11' - 11 1/4"

/2

8' - 11 1/2" 3' - 8"

/8

/2

IN401F4

S

IM

F1

SIM

CS

AE402

A4

LIVING/KITCHEN

AE501

F1

F3

IN501

2' - 8"

ALIGN FACE OF

PARTITION WITH WINDOW

EDGE

61 SF

CLOSET

143 SF

SLEEPING

288 SF

UNIT

140 SF

SLEEPING

44 SF

CLOSET

21 SF

HALL/LAVATORY

31 SF

BATHROOM

AE204

E3

A E

C

A E

E

12' - 10 1/4"

14' - 3"

16' - 10" 6' - 10" 5' - 0"

/4

/8

CS

IN402

A6

A3

IN402 A1

AE402

A6

7' - 6"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

AE401

L

IV

IN

G

U N

IT

E

N L A

R G

E D

F L O

O R

P L A

N S

J O

IN

T

B A

S E

L E

W

IS

-M C

C H

O R

D W

A

S E

A T

T L E

D

IS

T R

IC

T

E

M

A R

G

IN

A L W

A Y

S O

U T

H B

L D

G

S E

A T

T L E

W

A

-2

Y A

E G

E R

A R

C H

IT

E

C T

U R

E P

E N

R O

S E

L A

N E

S

U

IT

E

L E

N E

X A

K

S

K C

O U

G H

L

IN

K C

O U

G H

L

IN

C P

R Z

Y G

O D

A

M T

U R

N E

R

S

E P

T E

M B

E R

T B

D

T B

D

REVISION 04, AMENDMENT

R E

P A

IR

B

U

IL

D

IN

G

D E

S

IG

N C

O N

S T

R U

C T

IO

N

P K

G N

O C

E C

E

0 2' 4' 8'

SCALE: 1/4" = 1'

PLAN NORTH

1/4" = 1'-0"E1

UNIT-2RM ENLARGED FLOOR PLAN

1/4" = 1'-0"E6

UNIT-1RM ENLARGED FLOOR PLAN

1/4" = 1'-0"A1

UNIT-2RM-ALT ENLARGED FLOOR PLAN

TRUE NORTH

UNIT ACCESSORIES SCHEDULE

CODE DESCRIPTION

MC 16"W X 34"H SINGLE DOOR SURFACE MOUNTED MEDICINE CABINET

MG 24" X 36" GLASS MIRROR WITH CHANNEL FRAME

RH ROBE HOOK

SC/SCR SHOWER CURTAIN W/ HOOKS AND ROD; SCR TO BE LOCATED AND INSTALLED SO

THAT CURTAIN FALLS WITHIN THE FRONT EDGE OF SHOWER PAN

TPH TOILET PAPER HOLDER

CS CLOSET SHELF AND POLE - 14" DEEP. PROVIDE 3/4-INCH PLYWOOD SHELF WITH

PLASTIC LAMINATE (WHITE PLASTIC LAMINATE). POLE SHALL BE MADE OF SATIN

FINISH STAINLESS STEEL, 1-INCH DIAMETER, WITH FLANGES INCLUDED. PROVIDE

METAL BRACKETS AS REQUIRED TO SUPPORT 50 POUNDS PER LINEAR FOOT.

R

E V

IS

IO

N

A

M E

N D

M E

N T

/1

/2

R

E V

IS

IO

N

A

M E

N D

M E

N T

/0

/2

GENERAL ENLARGED FLOOR PLAN NOTES:

1. REFER TO SHEET AE601 FOR PARTITION TYPES AND SCHEDULE.

2. REFER TO SHEETS AE603-AE605 FOR DOOR SCHEDULE AND TYPES.

3. REFER TO SHEET AE540 FOR WINDOW SCHEDULE AND TYPES.

STAINLESS STEEL

CORNER GUARD,

ONE LEG LONGER.

CORNER GUARD

SHALL EXTEND FULL

HEIGHT OF

OPENING.

3"

M

IN

EXISTING MASONRY

WALL CONSTRUCTION1ST FLOOR

0"

C9

AE531

A9

AE531

STAINLESS STEEL

CORNER GUARD,

ONE LEG LONGER.

BEYOND

METAL STUDS @ 16" O.C.

5/8" GYPSUM BOARD

STEEL FRAME WITH

WRAP AROUND FOR

MASONRY

EXISTING MASONRY

WALL CONSTRUCTION

STEEL FRAME WITH

WRAP AROUND FOR

MASONRY

EXISTING MASONRY

WALL CONSTRUCTION

DOOR PER

SCHEDULE

DRIP FLASHING

CRIMPED OVER

RETURN FLASHING

BACKER ROD AND

CONTINUOUS

SEALANT BOTH SIDES

ALUMINUM

FRAME

EXISTING WALL

CONSTRUCTION

DOOR PER

SCHEDULE

EXISTING WALL

CONSTRUCTION

BACKER ROD

AND

CONTINUOUS

SEALANT BOTH

SIDES

ALUMINUM

FRAME

DOOR PER

SCHEDULE

ALUMINUM

DOOR FRAME

THRESHOLD

SET IN A BED

OF SEALANT

EXISTING

SLAB

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

AE531

D O

O R

A N

D O

P E

N

IN

G D

E T

A

IL

S

J O

IN

T

B A

S E

L E

W

IS

-M C

C H

O R

D W

A

S E

A T

T L E

D

IS

T R

IC

T

E

M

A R

G

IN

A L W

A Y

S O

U T

H B

L D

G

S E

A T

T L E

W

A

-2

Y A

E G

E R

A R

C H

IT

E

C T

U R

E P

E N

R O

S E

L A

N E

S

U

IT

E

L E

N E

X A

K

S

K C

O U

G H

L

IN

K C

O U

G H

L

IN

C P

R Z

Y G

O D

A

M T

U R

N E

R

S

E P

T E

M B

E R

T B

D

T B

D

REVISION 04, AMENDMENT

R E

P A

IR

B

U

IL

D

IN

G

D E

S

IG

N C

O N

S T

R U

C T

IO

N

P K

G N

O C

E C

E

3" = 1'-0"A9

CASED JAMB DETAIL

1/2" = 1'-0"A6

NEW UNIT OPENING ELEVATION

3" = 1'-0"C9

CEILING THROUGH OPENING

0 1'

SCALE: 3" = 1'

6"3"

3" = 1'-0"E9

CASED OPENING JAMB

3" = 1'-0"F9

CASED OPENING HEAD

3" = 1'-0"F4

EXT AL DOOR HEAD IN CMU

3" = 1'-0"C4

EXT AL DOOR JAMB IN CMU

3" = 1'-0"A4

EXT AL DOOR SILL IN CMU

R

E V

IS

IO

N

A

M E

N D

M E

N T

/0

/2

C1B

C1A

109 113B 113

110 110B108108B

157154

153A

164B

161B

B1B

B1A

101A

102A

102B

CORRIDOR

LOBBY

STORAGE

104B

MAIL ACCESS

ROOM

UTILITY

104A

FIRE ALARM

MECH

STAIR C

C1

NEC COMM

UNIT

UNIT

UNIT

UNISEX

MUDROOM

152A

FIRE RISER /

UTILITY

NEC COMM

FIRE ALARM

153A

MUDROOM

SWITCHGEAR

UNIT

STAIR B

B1

UNIT

ELEC /

COMMERCIAL

TELECOMM

JAN

C1C

104A104B

MECH

B1C

101B

101C

100B

VESTIBULE

C1D

B1D

102C

102D

100A

/A4 IN253

/A4 IN253

/A1 IN253 /A1 IN253

A

B C

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

IN252

F

IR

S T

F L O

O R

S

IG

N A

G E

P L A

N

A R

E A

B

J O

IN

T

B A

S E

L E

W

IS

-M C

C H

O R

D W

A

S E

A T

T L E

D

IS

T R

IC

T

E

M

A R

G

IN

A L W

A Y

S O

U T

H B

L D

G

S E

A T

T L E

W

A

-2

Y A

E G

E R

A R

C H

IT

E

C T

U R

E P

E N

R O

S E

L A

N E

S

U

IT

E

L E

N E

X A

K

S

K G

A L L

K G

A L L

C P

R Z

Y G

O D

A

M T

U R

N E

R

S

E P

T E

M B

E R

T B

D

T B

D

REVISION 04, AMENDMENT

R E

P A

IR

B

U

IL

D

IN

G

D E

S

IG

N C

O N

S T

R U

C T

IO

N

P K

G N

O C

E C

E

1/8" = 1'-0"A1

FIRST FLOOR SIGNAGE PLAN - AREA B

0 4' 8' 16'

SCALE: 1/8" = 1'

PLAN NORTH

MARK TYPE SIGN ROOM # PERMANENT TEXT

PANEL INSERT

TEXT

157 A2 157 PER GOVERNMENT PER GOVERNMENT

161 A1 161 N/A PER GOVERNMENT

161B A2 161B PER GOVERNMENT N/A

164 A1 164 N/A PER GOVERNMENT

164B A2 164B PER GOVERNMENT N/A

165 A2 165 PER GOVERNMENT N/A

166 A1 166 N/A PER GOVERNMENT

166B A2 166B PER GOVERNMENT N/A

169 A1 169 N/A PER GOVERNMENT

169B A2 169B PER GOVERNMENT N/A

171 A2 171 PER GOVERNMENT N/A

172 A1 172 N/A PER GOVERNMENT

172B A2 172B PER GOVERNMENT N/A

174 A1 174 N/A PER GOVERNMENT

174B A2 174B PER GOVERNMENT N/A

175 A1 175 N/A PER GOVERNMENT

175B A2 175B PER GOVERNMENT N/A

177 A1 177 N/A PER GOVERNMENT

177B A2 177B PER GOVERNMENT N/A

180 A1 180 N/A PER GOVERNMENT

180B A2 180B PER GOVERNMENT N/A

181 A2 181 JANITOR N/A

A1A B1 N/A STAIR N/A

A1B B2 N/A 1 N/A

A1C F1 N/A EXIT N/A

A1D J N/A SMOKING IS PROHIBITED ON PROPERTY SITE N/A

B1A B1 N/A STAIR N/A

B1B B2 N/A 1 N/A

B1C F1 N/A EXIT PER GOVERNMENT

B1D J N/A SMOKING IS PROHIBITED ON PROPERTY SITE N/A

B3A B1 N/A STAIR N/A

C1A B1 N/A STAIR N/A

C1B B2 N/A 1 N/A

C1C F1 N/A EXIT N/A

C1D J N/A SMOKING IS PROHIBITED ON PROPERTY SITE N/A

D1A B1 N/A STAIR N/A

D1B B2 N/A 1 N/A

D1C F1 N/A EXIT N/A

D1D J N/A SMOKING IS PROHIBITED ON PROPERTY SITE N/A

MARK TYPE SIGN ROOM # PERMANENT TEXT

PANEL INSERT

TEXT

100A L N/A PER GOVERNMENT N/A

100B J N/A SMOKING IS PROHIBITED ON PROPERTY SITE N/A

101A F1 N/A EXIT N/A

101B E PER GOVERNMENT PER GOVERNMENT PER GOVERNMENT

101C E PER GOVERNMENT PER GOVERNMENT PER GOVERNMENT

102A F1 N/A EXIT N/A

102B F1 N/A EXIT N/A

102C J N/A SMOKING IS PROHIBITED ON PROPERTY SITE N/A

102D J N/A SMOKING IS PROHIBITED ON PROPERTY SITE N/A

103 C1 103 UNISEX N/A

104 A1 104 MAIL ROOM ACCESS, UTILITY, STORAGE MAIL ROOM ACCESS,

UTILITY, STORAGE

104A A2 104A UTILITY N/A

104B A2 104B STORAGE N/A

105 O 105 FIRE ALARM N/A

107 G1 N/A PER GOVERNMENT PER GOVERNMENT

108 A1 108 N/A PER GOVERNMENT

108B A2 108B PER GOVERNMENT PER GOVERNMENT

109 A2 109 PER GOVERNMENT PER GOVERNMENT

110 A1 110 PER GOVERNMENT PER GOVERNMENT

110B A2 110B N/A PER GOVERNMENT

113 A1 113 N/A PER GOVERNMENT

113B A2 113B PER GOVERNMENT PER GOVERNMENT

115 A2 115 PER GOVERNMENT PER GOVERNMENT

116 A1 116 PER GOVERNMENT PER GOVERNMENT

116B A2 116B PER GOVERNMENT PER GOVERNMENT

118 A1 118 PER GOVERNMENT PER GOVERNMENT

118B A2 118B PER GOVERNMENT PER GOVERNMENT

119 A1 119 PER GOVERNMENT PER GOVERNMENT

119B A2 119B PER GOVERNMENT PER GOVERNMENT

121 A1 121 PER GOVERNMENT PER GOVERNMENT

121B A2 121B PER GOVERNMENT PER GOVERNMENT

124 A1 124 PER GOVERNMENT PER GOVERNMENT

124B A2 124B PER GOVERNMENT PER GOVERNMENT

125 A2 125 JANITOR N/A

151 A2 151 JANITOR N/A

152 G1 N/A MUDROOM N/A

153A O 153A FIRE ALARM N/A

154 A2 154 PER GOVERNMENT PER GOVERNMENT

156 P N/A PER GOVERNMENT N/A

R

E V

IS

IO

N

A

M E

N D

M E

N T

/0

/2

UNIT

UNIT

UTILITY

UNIT

UNIT

UNIT

UNIT

STAIR A

A1

UNIT

JAN

C O

R R

ID

O

R

166B

172B

175B

174B

180B

177B

169B

A1CA1BA1A

A1D

/A1 IN252 /A1 IN252

116B

119B 119

118B

121 121B

124B 124 125

D1B

D1A

STAIR D

D1

JAN

UNIT

UNIT

UNIT

MECH

UNIT

UNIT

D1C

D1D

/A1 IN252

/A1 IN252

A

B C

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

IN253

F

IR

S T

F L O

O R

S

IG

N A

G E

P L A

N

A R

E A

A A

N D

C

J O

IN

T

B A

S E

L E

W

IS

-M C

C H

O R

D W

A

S E

A T

T L E

D

IS

T R

IC

T

E

M

A R

G

IN

A L W

A Y

S O

U T

H B

L D

G

S E

A T

T L E

W

A

-2

Y A

E G

E R

A R

C H

IT

E

C T

U R

E P

E N

R O

S E

L A

N E

S

U

IT

E

L E

N E

X A

K

S

K G

A L L

K G

A L L

C P

R Z

Y G

O D

A

M T

U R

N E

R

S

E P

T E

M B

E R

T B

D

T B

D

REVISION 04, AMENDMENT

R E

P A

IR

B

U

IL

D

IN

G

D E

S

IG

N C

O N

S T

R U

C T

IO

N

P K

G N

O C

E C

E

1/8" = 1'-0"A1

FIRST FLOOR SIGNAGE PLAN - AREA A

1/8" = 1'-0"A4

FIRST FLOOR SIGNAGE PLAN - AREA C 0 4' 8' 16'

SCALE: 1/8" = 1'

PLAN NORTH

MARK TYPE SIGN ROOM # PERMANENT TEXT

PANEL INSERT

TEXT

157 A2 157 PER GOVERNMENT PER GOVERNMENT

161 A1 161 N/A PER GOVERNMENT

161B A2 161B PER GOVERNMENT N/A

164 A1 164 N/A PER GOVERNMENT

164B A2 164B PER GOVERNMENT N/A

165 A2 165 PER GOVERNMENT N/A

166 A1 166 N/A PER GOVERNMENT

166B A2 166B PER GOVERNMENT N/A

169 A1 169 N/A PER GOVERNMENT

169B A2 169B PER GOVERNMENT N/A

171 A2 171 PER GOVERNMENT N/A

172 A1 172 N/A PER GOVERNMENT

172B A2 172B PER GOVERNMENT N/A

174 A1 174 N/A PER GOVERNMENT

174B A2 174B PER GOVERNMENT N/A

175 A1 175 N/A PER GOVERNMENT

175B A2 175B PER GOVERNMENT N/A

177 A1 177 N/A PER GOVERNMENT

177B A2 177B PER GOVERNMENT N/A

180 A1 180 N/A PER GOVERNMENT

180B A2 180B PER GOVERNMENT N/A

181 A2 181 JANITOR N/A

A1A B1 N/A STAIR N/A

A1B B2 N/A 1 N/A

A1C F1 N/A EXIT N/A

A1D J N/A SMOKING IS PROHIBITED ON PROPERTY SITE N/A

B1A B1 N/A STAIR N/A

B1B B2 N/A 1 N/A

B1C F1 N/A EXIT PER GOVERNMENT

B1D J N/A SMOKING IS PROHIBITED ON PROPERTY SITE N/A

B3A B1 N/A STAIR N/A

C1A B1 N/A STAIR N/A

C1B B2 N/A 1 N/A

C1C F1 N/A EXIT N/A

C1D J N/A SMOKING IS PROHIBITED ON PROPERTY SITE N/A

D1A B1 N/A STAIR N/A

D1B B2 N/A 1 N/A

D1C F1 N/A EXIT N/A

D1D J N/A SMOKING IS PROHIBITED ON PROPERTY SITE N/A

MARK TYPE SIGN ROOM # PERMANENT TEXT

PANEL INSERT

TEXT

100A L N/A PER GOVERNMENT N/A

100B J N/A SMOKING IS PROHIBITED ON PROPERTY SITE N/A

101A F1 N/A EXIT N/A

101B E PER GOVERNMENT PER GOVERNMENT PER GOVERNMENT

101C E PER GOVERNMENT PER GOVERNMENT PER GOVERNMENT

102A F1 N/A EXIT N/A

102B F1 N/A EXIT N/A

102C J N/A SMOKING IS PROHIBITED ON PROPERTY SITE N/A

102D J N/A SMOKING IS PROHIBITED ON PROPERTY SITE N/A

103 C1 103 UNISEX N/A

104 A1 104 MAIL ROOM ACCESS, UTILITY, STORAGE MAIL ROOM ACCESS,

UTILITY, STORAGE

104A A2 104A UTILITY N/A

104B A2 104B STORAGE N/A

105 O 105 FIRE ALARM N/A

107 G1 N/A PER GOVERNMENT PER GOVERNMENT

108 A1 108 N/A PER GOVERNMENT

108B A2 108B PER GOVERNMENT PER GOVERNMENT

109 A2 109 PER GOVERNMENT PER GOVERNMENT

110 A1 110 PER GOVERNMENT PER GOVERNMENT

110B A2 110B N/A PER GOVERNMENT

113 A1 113 N/A PER GOVERNMENT

113B A2 113B PER GOVERNMENT PER GOVERNMENT

115 A2 115 PER GOVERNMENT PER GOVERNMENT

116 A1 116 PER GOVERNMENT PER GOVERNMENT

116B A2 116B PER GOVERNMENT PER GOVERNMENT

118 A1 118 PER GOVERNMENT PER GOVERNMENT

118B A2 118B PER GOVERNMENT PER GOVERNMENT

119 A1 119 PER GOVERNMENT PER GOVERNMENT

119B A2 119B PER GOVERNMENT PER GOVERNMENT

121 A1 121 PER GOVERNMENT PER GOVERNMENT

121B A2 121B PER GOVERNMENT PER GOVERNMENT

124 A1 124 PER GOVERNMENT PER GOVERNMENT

124B A2 124B PER GOVERNMENT PER GOVERNMENT

125 A2 125 JANITOR N/A

151 A2 151 JANITOR N/A

152 G1 N/A MUDROOM N/A

153A O 153A FIRE ALARM N/A

154 A2 154 PER GOVERNMENT PER GOVERNMENT

156 P N/A PER GOVERNMENT N/A

R

E V

IS

IO

N

A

M E

N D

M E

N T

/0

/2

C2B

C2A

209 213B 213

210 210B208208B

STAIR C

C2

NEC COMM

UNIT

UNIT

UNIT

UNIT

STOR

UNIT

UNIT

UTILITY

256C

FOYER

FIRE RISER

256D

NEC COMM

UNIT

UTILITY

UNIT

ELEC

UNIT

STAIR B

B2

ELEC /

COMMERCIAL

TELECOMM

FIRE ALARM

256B

JAN

256A

205 205B

256A

256B

256C 256D

202B

252B

264B

261B

B2B

B2A

UTILITY

/A4 IN263

/A4 IN263

/A1 IN263 /A1 IN263

A

B C

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

IN262

S E

C O

N D

F L O

O R

S

IG

N A

G E

P L A

N

A R

E A

B

J O

IN

T

B A

S E

L E

W

IS

-M C

C H

O R

D W

A

S E

A T

T L E

D

IS

T R

IC

T

E

M

A R

G

IN

A L W

A Y

S O

U T

H B

L D

G

S E

A T

T L E

W

A

-2

Y A

E G

E R

A R

C H

IT

E

C T

U R

E P

E N

R O

S E

L A

N E

S

U

IT

E

L E

N E

X A

K

S

K G

A L L

K G

A L L

C P

R Z

Y G

O D

A

M T

U R

N E

R

S

E P

T E

M B

E R

T B

D

T B

D

REVISION 04, AMENDMENT

R E

P A

IR

B

U

IL

D

IN

G

D E

S

IG

N C

O N

S T

R U

C T

IO

N

P K

G N

O C

E C

E

1/8" = 1'-0"A1

SECOND FLOOR SIGNAGE PLAN - AREA B

0 4' 8' 16'

SCALE: 1/8" = 1'

PLAN NORTH

MARK TYPE

SIGN

ROOM # PERMANENT TEXT

PANEL INSERT

TEXT

256D P 256D PER GOVERNMENT N/A

257 A2 257 ELECTRICAL N/A

258 A2 258 PER GOVERNMENT N/A

261 A1 261 N/A PER GOVERNMENT

261B A2 261B PER GOVERNMENT N/A

264 A1 264 N/A PER GOVERNMENT

264B A2 264B PER GOVERNMENT N/A

265 A2 265 PER GOVERNMENT N/A

266 A1 266 N/A PER GOVERNMENT

266B A2 266B PER GOVERNMENT N/A

269 A1 269 N/A PER GOVERNMENT

269B A2 269B PER GOVERNMENT N/A

271 A2 271 PER GOVERNMENT N/A

272 A1 272 N/A PER GOVERNMENT

272B A2 272B PER GOVERNMENT N/A

274 A1 274 N/A PER GOVERNMENT

274B A2 274B PER GOVERNMENT N/A

275 A1 275 N/A PER GOVERNMENT

275B A2 275B PER GOVERNMENT N/A

277 A1 277 N/A PER GOVERNMENT

277B A2 277B PER GOVERNMENT N/A

280 A1 280 N/A PER GOVERNMENT

280B A2 280B PER GOVERNMENT N/A

281 A2 281 JANITOR N/A

A2A B1 N/A STAIR N/A

A2B B2 N/A 2 N/A

B2A B1 N/A STAIR N/A

B2B B2 N/A 2 N/A

C2A B1 N/A STAIR N/A

C2B B2 N/A 2 N/A

D2A B1 N/A STAIR N/A

D2B B2 N/A 2 N/A

MARK TYPE

SIGN

ROOM # PERMANENT TEXT

PANEL INSERT

TEXT

201 A2 201 PER GOVERNMENT N/A

202 A1 202 N/A PER GOVERNMENT

202B A2 202B PER GOVERNMENT N/A

203 A2 203 PER GOVERNMENT N/A

205 A1 205 N/A PER GOVERNMENT

205B A2 205B PER GOVERNMENT N/A

208 A1 208 N/A PER GOVERNMENT

208B A2 208B PER GOVERNMENT N/A

209 A2 209 PER GOVERNMENT N/A

210 A1 210 N/A PER GOVERNMENT

210B A2 210B PER GOVERNMENT N/A

213 A1 213 N/A PER GOVERNMENT

213B A2 213B PER GOVERNMENT N/A

215 A2 215 PER GOVERNMENT N/A

216 A1 216 N/A PER GOVERNMENT

216B A2 216B PER GOVERNMENT N/A

218 A1 218 N/A PER GOVERNMENT

218B A2 218B PER GOVERNMENT N/A

219 A1 219 N/A PER GOVERNMENT

219B A2 219B PER GOVERNMENT N/A

221 A1 221 N/A PER GOVERNMENT

221B A2 221B PER GOVERNMENT N/A

224 A1 224 N/A PER GOVERNMENT

224B A2 224B PER GOVERNMENT N/A

225 A2 225 PER GOVERNMENT N/A

252 A1 252 N/A PER GOVERNMENT

252B A2 252B PER GOVERNMENT N/A

253 A1 253 N/A PER GOVERNMENT

256 A1 256 N/A PER GOVERNMENT

256A A2 256A PER GOVERNMENT N/A

256B O 256B PER GOVERNMENT N/A

256C A2 256C PER GOVERNMENT N/A

R

E V

IS

IO

N

A

M E

N D

M E

N T

/0

/2

C3B

309 313B 313

310 310B308308B 305 305B

356A

356B

356C 356D

302B

352B

364B

361B

B3B

ELEC /

COMMERCIAL

TELECOMM

STAIR B

B3

UNIT

UNIT

ELEC

NEC COMM

FIRE RISER

356D

UTILITY

356C

FOYER

FIRE ALARM

356B

JAN

356A

UNIT

UNIT

STORAGE

UNIT

ELEC

UNIT

UNIT

UNIT

UNIT

NEC COMM

STAIR C

C3

B3A

C3A

/A4 IN273

/A4 IN273

/A1 IN273

/A1 IN273 A

B C

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

IN272

T H

IR

D

F L O

O R

S

IG

N A

G E

P L A

N

A R

E A

B

J O

IN

T

B A

S E

L E

W

IS

-M C

C H

O R

D W

A

S E

A T

T L E

D

IS

T R

IC

T

E

M

A R

G

IN

A L W

A Y

S O

U T

H B

L D

G

S E

A T

T L E

W

A

-2

Y A

E G

E R

A R

C H

IT

E

C T

U R

E P

E N

R O

S E

L A

N E

S

U

IT

E

L E

N E

X A

K

S

K G

A L L

K G

A L L

C P

R Z

Y G

O D

A

M T

U R

N E

R

S

E P

T E

M B

E R

T B

D

T B

D

REVISION 04, AMENDMENT

R E

P A

IR

B

U

IL

D

IN

G

D E

S

IG

N C

O N

S T

R U

C T

IO

N

P K

G N

O C

E C

E

1/8" = 1'-0"A1

THIRD FLOOR SIGNAGE PLAN - AREA B

0 4' 8' 16'

SCALE: 1/8" = 1'

PLAN NORTH

MARK TYPE

SIGN

ROOM # PERMANENT TEXT

PANEL INSERT

TEXT

356D P 356D PER GOVERNMENT N/A

357 A2 257 ELECTRICAL N/A

358 A2 358 PER GOVERNMENT N/A

361 A1 361 N/A PER GOVERNMENT

361B A2 361B PER GOVERNMENT N/A

364 A1 364 N/A PER GOVERNMENT

364B A2 364B PER GOVERNMENT N/A

365 A2 365 PER GOVERNMENT N/A

366 A1 366 N/A PER GOVERNMENT

366B A2 366B PER GOVERNMENT N/A

369 A1 369 N/A PER GOVERNMENT

369B A2 369B PER GOVERNMENT N/A

371 G1 N/A PER GOVERNMENT PER GOVERNMENT

372 A1 372 N/A PER GOVERNMENT

372B A2 372B PER GOVERNMENT N/A

374 A1 374 N/A PER GOVERNMENT

374B A2 374B PER GOVERNMENT N/A

375 A1 375 N/A PER GOVERNMENT

375B A2 375B PER GOVERNMENT N/A

377 A1 377 N/A PER GOVERNMENT

377B A2 377B PER GOVERNMENT N/A

380 A1 380 N/A PER GOVERNMENT

380B A2 380B PER GOVERNMENT N/A

381 A2 381 JANITOR N/A

A3A B1 N/A STAIR N/A

A3B B2 N/A 3 N/A

B3B B2 N/A 3 N/A

C3A B1 N/A STAIR N/A

C3B B2 N/A 3 N/A

D3A B1 N/A STAIR N/A

D3B B2 N/A 3 N/A

MARK TYPE

SIGN

ROOM # PERMANENT TEXT

PANEL INSERT

TEXT

301 A2 301 PER GOVERNMENT N/A

302 A1 302 N/A PER GOVERNMENT

302B A2 302B PER GOVERNMENT N/A

303 A2 303 PER GOVERNMENT N/A

305 A1 305 N/A PER GOVERNMENT

305B A2 305B PER GOVERNMENT N/A

308 A1 308 N/A PER GOVERNMENT

308B A2 308B PER GOVERNMENT N/A

309 A2 309 PER GOVERNMENT N/A

310 A1 310 N/A PER GOVERNMENT

310B A2 310B PER GOVERNMENT N/A

313 A1 313 N/A PER GOVERNMENT

313B A2 313B PER GOVERNMENT N/A

316 A1 316 N/A PER GOVERNMENT

316B A2 316B PER GOVERNMENT N/A

318 A1 318 N/A PER GOVERNMENT

318B A2 318B PER GOVERNMENT N/A

319 A1 319 N/A PER GOVERNMENT

319B A2 319B PER GOVERNMENT N/A

321 A1 321 N/A PER GOVERNMENT

321B A2 321B PER GOVERNMENT N/A

324 A1 324 N/A PER GOVERNMENT

324B A2 324B PER GOVERNMENT N/A

325 A2 325 JANITOR N/A

340 G1 N/A PER GOVERNMENT PER GOVERNMENT

352 A1 352 N/A PER GOVERNMENT

352B A2 352B PER GOVERNMENT N/A

353 A1 353 N/A PER GOVERNMENT

356 A1 356 N/A PER GOVERNMENT

356A A2 356A PER GOVERNMENT N/A

356B O 356B PER GOVERNMENT N/A

356C A2 356C PER GOVERNMENT N/A

R

E V

IS

IO

N

A

M E

N D

M E

N T

/0

/2

9"

Administration

SIGN "A1"

SIGN 'E'

BASED ON UFC 3-120-01 FIGURE 4-15

PROVIDE ON ALL DOORS REQUIRING AN EXIT SIGN.

SIGN "F1"

SIGN 'C1'

PRINTED PAPER INSERT

WITH 3/4" HELVETICA NEUE

55 ROMAN ROOM

DESCRIPTION

WAYFINDING SIGN

ROOM IDENTIFICATION

SIGN WITH INSERT

9"

/2

ACCOMPANYING GRADE TWO

BRAILLE

EXIT IDENTIFICATION SIGN

1' - 8"

1101-1150

3" MESSAGE INSERT

PANELS WITH 1 1/2"

ARROWS AND 1"

MESSAGE TEXT

HELVETICA NEUE 65

MEDIUM

ARROWS ORIENTED

LEFT OR RIGHT AS

APPROPRIATE

ACCOMPANYING GRADE

TWO BRAILLE

1151-1199

UNISEX

9"

ACCOMPANYING GRADE

TWO BRAILLE

6" SYMBOLS

RESTROOM IDENTIFICATION

1" HELVETICA NEUE

55 ROMAN

ROOM NUMBER - 1 1/2"

HELVETICA NEUE - 55

ROMAN

ACCOMPANYIN…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .