12 32 00-Manufactured Wood Casework-EDITED-REV 02-ISSUED_AMENDMENT 0003.pdf

PDF 208 KB Posted

Attached to
“Repair Building 09175, Permanent Party UH” located on Joint Base Lewis-McChord, WA
Solicitation number
W912DW21B0008
Issued by

About this file

This document contains a specification for manufactured wood casework and an amendment to that specification for a federal construction project. The specification outlines requirements for wood cabinets, countertops, finishes, and materials to be installed at a permanent party unit headquarters building located on Joint Base Lewis-McChord in Washington state. Key changes in the amendment include replacing kitchen wall and base cabinets with recycled composite countertops, and deleting a paragraph on melamine laminated interior cabinet finishes.

View the file

Other files

File Type Posted
Abstract REV1 W912DW21B0008 Repair Building 9175 Permanent Party UH (SAM.gov).pdf PDF
Abstract W912DW21B0008 Repair Building 9175 Permanent Party UH (SAM.gov).pdf PDF
2021-09-09_JBLM-B9175-REV-04-DWGS_AMENDMENT 6.pdf PDF
Amendment 0006 W912DW21B0008 Repair Bldg 9175.pdf PDF
JBLM DPW Geospatial BIM CIM GIS and CAD Contract Requirements FY21_AMENDMENT 6.pdf PDF
2021-09-09-JBLM-B9175-REV-04-SPECS_AMENDMENT 6.pdf PDF
202109XX_CE0849 SOW_09175_AMENDMENT 6.pdf PDF
26 20 00-INTERIOR DISTRIBUTION SYSTEM-REVISION 03_AMENDMENT 5.pdf PDF
Amendment 0005 W912DW21B0008 Repair Bldg 9175.pdf PDF
20210831_Sign in Roster Repair Bldg 09175 Site Visit 2_AMENDMENT 5.pdf PDF
2021-09-03-JBLM-B9175-DWGS-REVISION 03-AMENDMENT 5.pdf PDF
DDC Controls As-Builts_AMENDMENT 0004.pdf PDF
Amendment 0004 W912DW21B0008 Repair Bldg 9175.pdf PDF
2021-08-20-JBLM-B9175-DWGS-REVISION 01-AMENDMENT 2.pdf PDF
2021-08-20-JBLM-B9175-SPECS-REVISION 01-AMENDMENT 2.pdf PDF
Amendment 0003 W912DW21B0008 Repair Bldg 9175.pdf PDF
Amendment 0002 W912DW21B0008 Repair Bldg 9175.pdf PDF
20210824_9175 Meeting Attendance Roster_AMENDMENT 0003.pdf PDF
01 30 00-Administrative Requirements-EDITED-REV 02_AMENDMENT 0003.pdf PDF
9175-Submittal Register_AMENDMENT 2.xlsx XLSX spreadsheet
20210820_CE0849 SOW_09175_AMENDMENT 2.pdf PDF
W912DW21B0008 Repair Bldg 9175.pdf PDF
9175 Location Site Visit Map.pdf PDF
2021-08-11_B9175 Submittal Register.xlsx XLSX spreadsheet
2021-08-10-JBLM 9175-SPECS-RTA REV001.pdf PDF
20210810_CE0849 SOW_09175.pdf PDF
JA Brand Names or Equal_JBLM 9175-Interior Finishes_Redacted.pdf PDF
Bldg 9175-Final Environmental Report.pdf PDF
Amendment 0001 W912DW21B0008 Repair Bldg 9175.pdf PDF
Barracks Buildings 9175 and 9176 as builts.pdf PDF
2021-08-10_JBLM-B9175-RTA-DWGS-REV01_Part2.pdf PDF
2021-08-10_JBLM-B9175-RTA-DWGS-REV01_Part1.pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Specification 12 32 00 – Manufactured Wood Casework

Specification 12 32 00 for this project is hereby modified as follows:

Spec 12 32 00-Manufactured Wood Casework

Descriptive Changes:

1. Replace with deleted section of paragraph 2.3.1 with the following:

Provide new factory-finished kitchen wall and base cabinets with recycled, composite countertops.

2. Paragraph 2.3.2.2, page 10, paragraph shall be deleted in its entirety.

SECTION 12 32 00

MANUFACTURED WOOD CASEWORK

11/16

Revised 03/18

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN HARDBOARD ASSOCIATION (AHA)

AHA A135.4 (1995; R 2004) Basic Hardboard

APA - THE ENGINEERED WOOD ASSOCIATION (APA)

APA E30 (2016) Engineered Wood Construction Guide

APA EWCG (2011) Engineered Wood Construction Guide:

Building Requirements and Related Panel Systems

APA PS 1 (2009) Structural Plywood (with Typical APA Trademarks)

ASME INTERNATIONAL (ASME)

ASME B18.6.1 (2016) Wood Screws (Inch Series)

ASTM INTERNATIONAL (ASTM)

ASTM A1008/A1008M (2016) Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardenable

ASTM A240/A240M (2017) Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications

ASTM A325 (2014) Standard Specification for Structural Bolts, Steel, Heat Treated, 120/105 ksi Minimum Tensile Strength

ASTM A325M (2014) Standard Specification for Structural Bolts, Steel, Heat Treated, 830 MPa Minimum Tensile Strength (Metric)

ASTM C1036 (2016) Standard Specification for Flat Glass

ASTM D4689 (2012) Standard Specification for

SECTION 12 32 00 Page 1

Adhesive, Casein-Type

ASTM D4690 (2012) Standard Specification for Urea Formaldehyde Resin Adhesives

ASTM F594 (2009; E 2015) Standard Specification for Stainless Steel Nuts

ASTM F836M (2016) Standard Specification for Style 1 Stainless Steel Metric Nuts (Metric)

BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)

ANSI/BHMA A156.9 (2015) Cabinet Hardware

COMPOSITE PANEL ASSOCIATION (CPA)

CPA A208.1 (2016) Particleboard

HARDWOOD PLYWOOD AND VENEER ASSOCIATION (HPVA)

HPVA HP-1 (2016) American National Standard for Hardwood and Decorative Plywood

KITCHEN CABINET MANUFACTURERS ASSOCIATION (KCMA)

KCMA A161.1 (2017) Performance & Construction Standards for Kitchen and Vanity Cabinets

MASTER PAINTERS INSTITUTE (MPI)

MPI 10 (2012) Latex, Exterior Flat (MPI Gloss Level 1)

MPI 119 (2012) Latex, Exterior, Gloss (MPI Gloss Level 6)

MPI 28 (2012) Varnish, Marine Spar, Exterior, Gloss (MPI Gloss Level 6)

MPI 9 (2012) Alkyd, Exterior Gloss (MPI Gloss Level 6)

MPI 91 (2012) Paste, Wood Filler

NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)

ANSI/NEMA LD 3 (2005) Standard for High-Pressure Decorative Laminates

SCIENTIFIC EQUIPMENT AND FURNITURE ASSOCIATION (SEFA)

SEFA 7 (2007) Recommended Practice for Laboratory and Hospital Fixtures

U.S. DEPARTMENT OF COMMERCE (DOC)

DOC/NIST PS1 (1995) Structural Plywood

SECTION 12 32 00 Page 2

DOC/NIST PS20 American Softwood Lumber Standard

U.S. GENERAL SERVICES ADMINISTRATION (GSA)

FS FF-B-588 (Rev E; Notice 1) Bolt, Toggle: and Expansion Sleeve, Screw

FS FF-S-325 (Basic; Int Amd 3; Notices 3, 4) Shield, Expansion; Nail, Expansion; and Nail, Drive Screw (Devices, Anchoring, Masonry)

FS MM-L-736 (Rev D; Notice 1) Lumber; Hardwood

FS TT-C-490 (Rev F; Am 3) Cleaning Methods for Ferrous Surfaces and Pretreatments for Organic Coatings

FS WW-P-541 (Rev E; Am 1; Notice 1) Plumbing Fixtures

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Fabrication ; G

Installation Drawings ; G

SD-03 Product Data

Cabinets ; G

Corrosion-Resistant Steel ; G

Plywood ; G

Medium Density Fiberboard (MDF) ; G

Hardwood ; G

Hardwood Plywood ; G

Glass ; G

Adhesives ; G

Filler Material ; G

Particle Board ; G

Varnish ; G

SECTION 12 32 00 Page 3

Fasteners ; G

Steel Sinks ; G

Service Fixtures ; G

Accessories and Hardware ; G

Softwoods ; G

Plastic Laminate ; G

Countertops ; G

SD-04 Samples

Accessories and Hardware ;

Manufacturer's Standard Color Charts ; G

SD-07 Certificates

Corrosion-Resistant Steel

Plywood

Hardwood

Glass

Adhesives

Filler Material

Particle Board

Varnish

Fasteners

Steel Sinks

Service Fixtures

Accessories and Hardware

SD-08 Manufacturer's Instructions

Manufacturer's Instructions

1.3 QUALITY CONTROL

Submit manufacturer's standard color charts for wood and metal cabinets showing the manufacturer's recommended color and finish selections.

1.4 DELIVERY, STORAGE, AND HANDLING

Deliver, handle, and store cabinets in a manner that prevents damage or deformity.

SECTION 12 32 00 Page 4

PART 2 PRODUCTS

2.1 SYSTEM DESCRIPTION

Provide wood cabinets, factory-fabricated and finished in the manufacturer's standard sizes and finishes of the type, design, and configuration indicated on drawings. Construct cabinets as specified meeting the requirements of KCMA A161.1 . Provide wall and base cabinet assemblies consisting of individual units joined into continuous sections. Use fastenings that permit removal and replacement of individual units without affecting the remainder of the installation.

Provide counters with watertight sink rim when indicated, and removable drawers equipped with position stops to avoid accidental complete withdrawals. Fix or adjust shelves as indicated.

2.2 FABRICATION

2.2.1 Wood Cabinet Fabrication

Construct wall and base cabinets with frame fronts and solid ends, or frame construction throughout. Provide 3/4 by 1-1/2 inch kiln-dried hardwood framing members, using mortise and tenon, dovetailed, grove and lapped, biscuit and dado, or doweled, with glue assembly. Brace top and bottom corners with hardwood blocks that are glued with water-resistant glue and nailed in place. Provide base cabinets with an integral toe space at least 2-1/2 inches deep and 4 inches high. Mount drawers on metal guides . Provide removable and adjustable shelving, as indicated.

Provide minimum thicknesses of materials for frame-front, solid-end cabinet construction as follows:

a. Backs and bottoms of base cabinets and tops of wall cabinets: 1/8 inch tempered hardboard. Brace bottoms with wood members glued in place.

b. Cabinet ends: 1/2 inch hardwood-veneer plywood

c. Doors: 3/4 inch hardwood plywood, solid core doors

d. Drawer fronts: 3/4 inch hardwood

e. Drawer bottoms: 3/16 inch plywood or tempered hardboard. Brace drawer bottoms over 15 inches wide with wood members glued in place.

f. Drawer sides and backs: 1/2 inch hardwood

g. Interior partitions or dividers: 1/2 inch fir plywood, Grade A-A

h. Shelves: Grade A-B plywood, supported on ends and 24 inches on centers

i. Adjustable shelves: 3/4 inch plywood

j. Base cabinet shelves: 5/8 inch plywood

k. Wall cabinet shelves: 1/2 inch plywood

Provide minimum thicknesses of materials for frame-type cabinet construction as follows:

SECTION 12 32 00 Page 5

a. Cabinet ends: 1/4 inch hardwood plywood

b. Backs, bottoms, partitions, and dividers: 3/16 inch tempered hardboard in a frame

Provide materials for other components as specified.

2.2.1.1 High-Pressure Decorative Laminate (HPDL)

ANSI/NEMA LD 3 , satin finish, unless otherwise indicated.

a. Countertops: PF 42, satin finish

b. Vertical Surfaces: GP 28 or PF 30, satin finish

c. Backing Sheet: BK 20

d. Cabinet Liner: CL 20

2.2.1.2 Hardwood Plywood

HPVA HP-1 , Type II (Interior), three- or five-ply, with face veneer of good grade (1) or better. Cover all exposed edges.

2.2.1.3 Hardwood

Provide hardwood for use in cabinet work, thoroughly seasoned or kiln-dried to 12-15 percent mc; without defects in any exposed parts or surfaces.

2.2.1.4 Softwood Plywood

Comply with DOC/NIST PS1 .

a. Countertops: Exterior type, A-C Grade

b. Elsewhere: Interior type, A-B Grade, may be used in lieu of hardwood plywood where HPDL finish is provided.

2.2.1.5 Hardboard

In accordance with AHA A135.4 , tempered

2.2.1.6 Steel for Cabinets

ASTM A1008/A1008M , cold rolled, commercial quality carbon steel sheet

2.2.1.7 Sinks , Lavatories and Fittings

As specified in Section 22 00 00 PLUMBING, GENERAL PURPOSE.

2.2.2 Particle Board Cabinet Fabrication

Construct frameless wall and base cabinets with solid particleboard panels throughout, using mortise and tenon, grooved and lapped, doweled and glue assembly. Brace top and bottom corners with hardwood blocks that are glued with water-resistant glue and nailed in place. Provide base cabinets with an integral toe space at least 2-1/2-inches deep and 4 inches

SECTION 12 32 00 Page 6 high. Mount drawers on metal guides . Provide removable and adjustable shelving, as indicated on drawings.

Provide minimum thicknesses of materials for cabinet construction as follows:

a. Backs and bottoms of base cabinets and tops of wall cabinets: 5/8 inch Grade M-2 exterior glue

b. Exposed cabinet ends: 5/8 inch particle board with a plastic laminate covering

c. Doors: 3/4 inch particle board laminated on front surface rear surface all edges

d. Drawer fronts: 3/4 inch particle board laminated on all edges

e. Drawer bottoms: 1/8 inch plywood or tempered hardboard. Brace drawer bottoms over 15 inches wide with wood members glued in place.

f. Drawer sides and backs: 1/2 inch particle board

g. Interior partitions or dividers: 1/2 inch particle board

h. Shelves: Supported on ends and 24 inches on centers

i. Adjustable shelves: 3/4 inch particle board

j. Base cabinet shelves: 5/8 inch particle board

k. Wall cabinet shelves: 1/2 inch particle board

2.2.3 Plywood Cabinet Fabrication

Construct frameless wall and base cabinets with solid plywood panels throughout using mortise and tenon, grooved and lapped, doweled, with glue assembly. Brace top and bottom corners with hardwood blocks that are glued with water-resistant glue and nailed in place. Provide base cabinets with an integral toe space at least 2-1/2 inches deep and 4 inches high. Mount drawers on metal guides . Provide removable and adjustable shelving, as indicated on drawings.

Provide minimum thicknesses of materials for cabinet construction as follows:

a. Backs and bottoms of base cabinets and tops of wall cabinets: 3/16 inch tempered hardboard. Brace bottoms with wood members glued in place.

b. Cabinet ends: 3/4 inch standard veneer-core plywood with a plastic laminate covering

c. Doors: 3/4 inch standard veneer-core plywood laminated on front surface rear surface all edges

d. Drawer fronts: 3/4 inch standard veneer-core plywood laminated on all edges

e. Drawer bottoms: 1/8 inch plywood or tempered hardboard. Brace drawer

SECTION 12 32 00 Page 7 bottoms over 15 inches wide with wood members glued in place.

f. Drawer sides and backs: 3/4 inch standard veneer-core plywood

g. Interior partitions or dividers: 34 inch standard veneer-core plywood

h. Shelves: Supported on ends and 24 inches on centers

i. Adjustable shelves: 3/4 inch standard veneer-core plywood

j. Base cabinet shelves: 3/4 inch standard veneer-core plywood

k. Wall cabinet shelves: 3/4 inch standard veneer-core plywood

2.2.4 Melamine Cabinet Fabrication

Construct cabinets with frame fronts and solid ends throughout. Frame members must be 3/4 by 1-1/2 inch kiln-dried hardwood, using mortise and tenon, dovetailed or doweled, and glued together. Brace top and bottom corners with hardwood blocks that are glued with water-resistant glue and nailed in place. Provide base cabinets with an integral toe space at least 2-1/2 inches deep and 4 inches high. Mount drawers on metal guides .

Provide removable and adjustable shelving, as indicated on drawings.

Provide minimum thicknesses of materials for cabinet construction as follows:

a. Backs and bottoms of base cabinets and tops of wall cabinets: 3/16 inch tempered hardboard. Brace bottoms with wood members glued in place.

b. Cabinet ends: 3/4 inch melamine particle board with a plastic laminate covering

c. Doors: 3/4 inch melamine particle board laminated on front surface rear surface all edges

d. Drawer fronts: 3/4 inch melamine particle board laminated on all edges

e. Drawer bottoms: 1/8 inch plywood or tempered hardboard. Brace drawer bottoms over 15 inches wide with wood members glued in place.

f. Drawer sides and backs: 5/8 inch melamine particle board

g. Interior partitions or dividers: 5/8 inch melamine particle board

h. Shelves: Supported on ends and 24 inches on centers

i. Adjustable shelves: 3/4 inch melamine particle board

j. Base cabinet shelves: 5/8 inch melamine particle board

k. Wall cabinet shelves: 5/8 inch melamine particle board

2.2.5 Laminate Cabinet Fabrication

Construct cabinets with frame fronts and solid ends throughout. Frame members must be 3/4 by 1-1/2 inch kiln-dried hardwood, using mortise and tenon, dovetailed or doweled, and glued together. Brace top and bottom

SECTION 12 32 00 Page 8 corners with hardwood blocks that are glued with water-resistant glue and nailed in place. Provide base cabinets with an integral toe space at least 2-1/2 inches deep and 4 inches high. Mount drawers on metal guides .

Provide removable and adjustable shelving, as indicated on drawings.

Provide minimum thicknesses of materials for cabinet construction as follows:

a. Backs and bottoms of base cabinets and tops of wall cabinets: 3/16 inch tempered hardboard. Brace bottoms with wood members glued in place.

b. Cabinet ends: 3/4 inch standard veneer-core plywood with a plastic laminate covering

c. Doors: 3/4 inch low pressure laminate

d. Drawer fronts: 3/4 inch low pressure laminate

e. Drawer bottoms: 1/8 inch plywood or tempered hardboard. Brace drawer bottoms over 15 inches wide with wood members glued in place.

f. Drawer sides and backs: 3/4 inch standard veneer-core plywood

g. Interior partitions or dividers: 3/4 inch standard veneer-core plywood

h. Shelves: Supported on ends and 24 inches on centers

i. Adjustable shelves: 3/4 inch standard veneer-core plywood

j. Base cabinet shelves: 3/4 inch standard veneer-core plywood

k. Wall cabinet shelves: 3/4 inch standard veneer-core plywood

2.2.6 Miscellaneous Cabinets

2.2.6.1 Combination Sink-and-Base Cabinet

A combination sink-and-base cabinet unit may be furnished in lieu of the base cabinet and inset sink indicated provided the combination unit affords facilities and space equal to those indicated and provided the combination unit matches the adjacent units in materials and construction. Provide a sink with matching drainboards, of corrosion-resistant steel or porcelain-enamel steel, equipped with a chromium-plated swinging-spout faucet, chromium-plated water-control valves, or automatic faucet and chromium-plated cup strainer. Ensure joints are watertight between sink and drainboard and between drainboard and counter top.

2.2.6.2 Special Purpose Cabinets

Provide special-purpose cabinets, such as cabinets for eye-level oven units, countertop range units, and built-in refrigerators and desks, as indicated on drawings, of the same materials and construction as adjacent cabinets. Provide space adjacent to sink for a dishwasher, as indicated.

SECTION 12 32 00 Page 9

2.3 MANUFACTURED UNITS

2.3.1 Cabinets

Provide new factory-finished kitchen wall and base cabinets with high pressure decorative laminate (HPDL) countertops and bathroom vanity cabinets with HPDL countertops to receive combination lavatory-countertops as specified in Section 22 00 00 PLUMBING, GENERAL PURPOSE. Provide cabinets conforming to KCMA A161.1 , requirements specified herein, bearing the "KCMA Certified Cabinet" seal of the Kitchen Cabinet Manufacturers Association, or submit manufacturer's test reports from an approval laboratory that cabinets meet requirements of KCMA A161.1 . Provide countertops conforming to requirements specified herein.

2.3.1.1 Frame Type Cabinets

Provide cabinets with frame fronts and solid ends. Provide 3/4 inch thick by 1-1/2 inch wide frame members; kiln-dried hardwood, glued together, either mortised and tenoned, dovetailed or doweled, nailed, stapled or screwed. Brace top and bottom corners with either hardwood blocks that are glued together with water resistant glue and nailed in place, or metal or plastic corner braces. Use 1/8 inch thick plywood for backs of cabinets,with tempered hardboard or 3/8 inch thick, 44 pound density particle board. Provide 3/8 inch thick hardwood or 3/8-inch thick, 44 pound density particle boardfor backs of cabinets. Provide cabinet ends made with 5/8 inch thick, 44 pound density particle board core Plywood.

2.3.1.2 Frameless Type Cabinets

Provide cabinets of frameless design and construction. Construct cabinets of minimum 5/8 inch thick, 44 pound density particle board end and floor panels. Construct cabinet back of minimum 3/16 inch thick, 44 pound density particle board. Dowel and glue hanging rails to end panels, then fastened and hot melt glued to cabinet back. Provide toe kick plates that are recessed, doweled and glued to the end panels. Brace top and bottom corners with either hardwood blocks glued together with water resistant glue and nailed in place, or fastened with metal or plastic corner braces.

2.3.2 Finish

2.3.2.1 Cabinet Finish

Provide cabinets with a factory-applied durable finish in accordance with KCMA A161.1 requirements and of a type standard with the manufacturer.

Fabricate natural finish wood doors, drawer fronts, cabinet fronts, and exposed cabinet sides of wood, free of extreme color variations within each panel or between adjacent panels. For exposed exterior surfaces, provide hardwood or grade A-A hardwood veneer with natural stain and sprayed on factory applied finish. melamine plastic finish. paint-finished wood doors, drawer fronts, cabinet fronts, and exposed cabinet sides fabricated of hardwood or grade C hardwood veneer.

2.3.2.2 Melamine Laminated Interior Cabinet Finish

Finish plywood, particle board or tempered hardboard cabinet backs with a melamine laminate on the exposed side. Cover particle board shelves on both sides with a laminated melamine finish. Provide Melamine laminate that conforms to the requirements of ANSI/NEMA LD 3 and laminate adhesive that is contact type applied to both surfaces.

SECTION 12 32 00 Page 10

2.3.2.3 Backer Sheets

Provide backer sheets of high pressure plastic laminate, conforming to ANSI/NEMA LD 3 , Grade BK20, applied to the underside of all core material.

2.3.3 Color, Texture, And Pattern

Provide color as indicated on the drawings. Color listed is not intended to limit the selection of equal colors from other manufacturers.

2.4 MATERIALS

Provide steel for cabinet construction conforming to ASTM A1008/A1008M .

Provide corrosion-resistant steel conforming to ASTM A240/A240M , Type 304 Finish 4.

Provide douglas-fir plywood conforming to APA E30 , APA EWCG, and APA PS 1 exterior type, fully waterproof bond.

Provide glass conforming to ASTM C1036, Type I, Class 1, Quality q3, 1/4 inch thick, for unframed sliding glass doors; other glass to conform to ASTM C1036, Type II, Class 1, Quality q8, 7/32 inch thick.

Provide adhesives for application of plastic laminate consisting of a thermosetting urea-resin Type II conforming to ASTM D4690 as recommended by the manufacturer of the laminate. Provide adhesive for wood members conforming to ASTM D4689.

Provide filler material conforming to MPI 91 .

Provide hardwood conforming to FS MM-L-736 , standard hardwood lumber, S2S.

Provide hardwood plywood conforming to HPVA HP-1 .

Provide particle board conforming to CPA A208.1 , Type 1, Grade M or medium density.

Provide plastic laminate conforming to ANSI/NEMA LD 3 , Style as indicated in the Delivery Order, Type as indicated in the Delivery Order, Grade as indicated in the Delivery Order, Class as indicated in the Delivery Order, Finish as indicated in the Delivery Order.

Provide softwoods conforming to DOC/NIST PS20 , factory and shop grade.

Provide varnish conforming to MPI 28 .

Provide accessories and hardware conforming to the following requirements, as applicable:

a. Extension drawer slides: ANSI/BHMA A156.9 , Type B85071

b. Semiconcealed hinges: ANSI/BHMA A156.9 , Type B81201, 1-1/2 inches

c. Full surface hinges: ANSI/BHMA A156.9 , Type B81131, 1-1/2 inches

d. Knob pulls: ANSI/BHMA A156.9 , 1-inch diameter, Type B12132

SECTION 12 32 00 Page 11

e. Bar type pulls: ANSI/BHMA A156.9 , 4-inch overall length, Type B12012

f. Semiconcealed hinges: ANSI/BHMA A156.9 , Type B81201, 40 millimeter

g. Full surface hinges: ANSI/BHMA A156.9 , Type B81131, 40 millimeter

h. Knob pulls: ANSI/BHMA A156.9 , 25 millimeter diameter, Type B12132

i. Bar type pulls: ANSI/BHMA A156.9 , 100 millimeter overall length, Type B12012

j. Locks, keying, and keys: As directed

k. Catches: Magnetic, 5 pound pull

l. Sliding door set: Impregnated fiberboard track, Nylon glides

Provide fasteners conforming to the following:

a. Screws: ASME B18.6.1 , Group, Type and Class as applicable

b. Anchoring Devices: FS FF-S-325 , Group, Type, and Class as applicable

c. Toggle bolts: FS FF-B-588 , Type I, Class A, Style 2

d. Nuts: ASTM F594, corrosion-resistant steel

e. Bolts: ASTM A325, heavy, hexagon head bolts corrosion-resistant steel

f. Nuts: ASTM F836M, corrosion-resistant steel

g. Bolts: ASTM A325M, heavy, hexagon head bolts corrosion-resistant steel

Provide corrosion-resistant steel sinks conforming to the following requirements:

b. 18-gage corrosion-resistant steel, nonintegral, self-rimming

c. Drain holes in center of bowl

d. Underside coated with 1/8 inch thick sound deadener

e. Die-form, seamless, raised edges at front and ends

f. Cove corners to 1/2 inch radius

g. Equip with strainers and tail pieces

Provide service fixtures conforming to the following requirements:

a. Provide fixtures in accordance with the water conservation policy as stated in the Standard Plumbing Codes, Appendix J.

b. Faucets: splashback mounted, cast brass, chrome plated, FS WW-P-541

c. Faucets: deck mounted, cast brass, chrome plated, FS WW-P-541

d. Gas, air, and vacuum, distilled water, steam, and de-ionized water cocks: cast brass, chrome plated, ground key type

SECTION 12 32 00 Page 12

e. Drains, strainers, and taps: brass, chrome plated, FS WW-P-541

f. Index buttons: plastic, color codes in accordance with SEFA 7

g. Special items: provide nipples and locknuts with each fixture as directed.

Provide the following coating:

a. Metal pretreatment coatings: FS TT-C-490 , Type I

b. Metal pretreatment coatings: FS TT-C-490 , Type II

c. Metal pretreatment coatings: FS TT-C-490 , Type III

d. Enamel: MPI 10 MPI 11 MPI 119

2.5 ACCESSORIES AND HARDWARE

Provide accessories such as utility shelves and racks for extracts, condiments, and towels; bins for sugar and flour; breadboxes; and trays for cutlery and flatware as indicated.

Provide corrosion resistant hardware, and all exposed hardware with a chromium-plated finish or a corrosion-resistant finish as approved. Paint semiconcealed hinges on cabinets where paint finish is required to match the cabinets. Equip doors with bullet-type catches spring hinges magnetic-type catches. Provide door and drawer pulls as indicated.

PART 3 EXECUTION

Submit manufacturer's instructions for wood and metal cabinet systems including special provisions required to install equipment components and system packages. Submit special notices to detail impedances, hazards and safety precautions.

3.1 INSTALLATION

3.1.1 Factory Finishing of Wood Cabinets

For painted finish, apply a prime coat and two coats of synthetic enamel of air-drying quality, conforming to MPI 9 MPI 94 , Class A. Provide colors as selected.

For natural finish, use the applicable procedure for the type of wood selected as follows:

a. For open-grain woods: Apply one coat of paste wood filler, and remove excess filler. Then apply one coat of pale varnish thinned with turpentine, followed by one coat of pale varnish and then by one coat of satin-finish varnish, plus an additional coat of satin-finish varnish on cabinet doors and drawer fronts. Lightly sand surfaces between coats.

b. For close-grain woods: Apply one coat of pale varnish thinned with turpentine, followed by one coat of pale varnish and then by one coat of satin-finish varnish, plus an additional coat of satin-finish varnish on cabinet doors and drawer fronts. Lightly sand surfaces

SECTION 12 32 00 Page 13 between coats.

At the Contractor's option, Wood cabinets with a factory finish standard set by the cabinet manufacturer shall be provided.

3.1.2 Cabinet Installation

Install casework plumb with countertops level to within 1/16 inch in 10 feet . Level base cabinets by adjusting leveling screws. Scribe and fit scribe strips to irregularities of adjacent surfaces. Gap opening is not to exceed 0.025-inch .

Secure cases permanently to floor and wall construction using 1/4 inch diameter masonry anchors, spaced 30 inches maximum on center, with a minimum of two for each case.

Support wall cases on continuous 18-gage galvanized steel hanging brackets. Secure wall cases in position with screws to blocking. Bolt adjoining cases together. Ensure width of joints does not exceed 1/32 inch .

Provide closer strips, filler strips, and finish moldings as required.

Align doors, adjust hardware, clean and wax surfaces.

Submit installation drawings for cabinets. Include in drawings location of cabinets, details of cabinets related and dimensional positions, and locations for roughing in plumbing, including sinks, faucets, strainers and cocks.

3.2 ADJUSTING AND CLEANING

3.2.1 Inspection

Examine casework grounds and supports for adequate anchorage, foreign material, moisture, and unevenness that could prevent quality casework installation. Ensure that electrical and plumbing rough-ins for casework are complete. Do not proceed with installation until defects are corrected.

3.2.2 Cleaning

On completion of cabinet installation, touch up marred or abraded finished surfaces. Remove crating and packing materials from premises. Wipe down surfaces to remove fingerprints and markings and leave in clean condition.

-- End of Section --