This document provides details on a federal solicitation opportunity. Solicitation number W912DW21B0008 from the Department of the Army Corps of Engineers Engineering District Seattle seeks offers for repair work on Building 09175, Permanent Party UH, located at Joint Base Lewis-McChord in Washington. The solicitation involves repairing the specified building on the military base. Interested parties should respond in accordance with the terms and conditions outlined in the full solicitation document.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REFER TO PLAN NOTES# ROOM CALLOUT
DEMOLITION PEN WEIGHT - COMPONENT MAY ALSO BE SHADED
CONNECT NEW TO EXISTING. VERIFY EXACT LOCATION.
REVISION NUMBER
EXISTING COMPONENT PEN WEIGHT
EXISTING EQUIPMENT OR MATERIAL DESIGNATION(E)
DISCONNECT FROM EXISTING. VERIFY EXACT LOCATION.
E.C. ELECTRICAL CONTRACTOR
GENERAL CONTRACTORG.C.
P.C. PLUMBING CONTRACTOR
M.C. MECHANICAL CONTRACTOR
TEMPERATURE CONTROL CONTRACTORT.C.C.
SYMBOL DESCRIPTION SYMBOL DESCRIPTION
HVAC & PLUMBING SYMBOL SCHEDULE
DEDICATED OUTSIDE AIR UNITDOAU
DP DIFFERENTIAL PRESSURE
UH UNIT HEATER
COMPUTER ROOM AIR CONDITIONING UNITCRAC
24x12
24x12
24x12
RETURN DUCT RISER
SUPPLY DUCT DROP
SUPPLY DUCT RISER
RETURN DUCT DROP
FLEXIBLE DUCT
TURNING VANES
(UP)DUCT SEC., POSITIVE PRESSURE-FIRST SIZE IS TOP DIM.(TYP.)
(DOWN) DUCT SECTION, POSITIVE PRESSURE
(UP) DUCT SECTION, NEGATIVE PRESSURE
R
24x12
18x12
BALANCING DAMPER W/ MANUAL LOCKING QUADRANT
SIDE WALL SUPPLY REGISTER
(DOWN) DUCT SECTION, NEGATIVE PRESSURE
DUCT SIZE, FIRST FIGURE IS SIDE SHOWN-CLEAR INSIDE DIM.
DUCT CHANGE OF ELEVATION RISE(R) DROP(D)
FLEXIBLE CONNECTION
BALANCING DAMPER W/ MOTORIZED LOCKING QUADRANT
TH ELECTRIC OR DDC THERMOSTAT (TSTAT)
FIRE DAMPER IN FLOOR (HORIZONTAL POSITION)FD
SD SMOKE DAMPER
FD FIRE DAMPER IN WALL (VERTICAL POSITION)
ELECTRIC OR DDC HUMIDISTAT (HSTAT)
S
T
M
H
TEMPERATURE SENSOR
MOTOR
HUMIDITY SENSOR
R RADIATION DAMPER
COMBINATION FIRE/SMOKE DAMPER (HORIZONTAL POSITION)FSD
FSD COMBINATION FIRE/SMOKE DAMPER (VERTICAL POSITION)
OPPOSED BLADE DAMPEROBD
TOP OF DUCT ELEVATION ABOVE FLOOR
BOD
TOD
TF TRANSFER FAN
ROOFTOP UNITRTU
OA
SA SUPPLY AIR
OUTSIDE AIR
AIR HANDLING UNIT
RETURN AIRRA
AHU
BOTTOM OF DUCT ELEVATION ABOVE FLOOR
BOS BOTTOM OF STEEL
EF EXHAUST FAN
FCU FAN COIL UNIT
VAV VARIABLE AIR VOLUME UNIT
EA EXHAUST AIR
RECTANGULAR - OPPOSED BLADE / ROUND - BUTTERFLY
RECTANGULAR - OPPOSED BLADE / ROUND - BUTTERFLY
HWSCWS HOT WATER SUPPLY LINE (HWS)CHILLED WATER SUPPLY LINE (CWS)
HWRCWR HOT WATER RETURN LINE (HWR)CHILLED WATER RETURN LINE (CWR)
CS COOLING TOWER WATER SUPPLY (CS)
CR COOLING TOWER WATER RETURN (CR)
CWP CHILLED WATER PUMP
HWP HOT WATER PUMP
CHWP CHILLED/HOT WATER PUMP
CWPP CHILLED WATER PRIMARY PUMP
CWSP CHILLED WATER SECONDARY PUMP
HOT WATER SECONDARY PUMPHWSP
HOT WATER PRIMARY PUMPHWPP
GAS COCK
GATE VALVE / SHUT OFF VALVE
VALVE IN RISER
VALVE IN DROP
BUTTERFLY VALVE
2-WAY CONTROL VALVE (PNEUMATIC)
3-WAY CONTROL VALVE (PNEUMATIC)
BALL VALVE
PLUG VALVE
STRAINER
THERMOMETER
PRESSURE GAUGE
GLOBE VALVE
CHECK VALVE3 PIECE BALL VALVE
WAFER CHECK VALVEEMERGENCY VALVE WITH FIRE LINK
HYDRAULIC VALVE
2-WAY CONTROL VALVE (ELECTRIC)
PRESSURE REDUCING VALVE (PRV)
CALIBRATED BALANCE VALVE - CIRCUIT SETTER
CALIBRATED ORIFICE PLATE FLOW METER
AUTOMATIC FLOW CONTROL VALVE
SPRING HANGER
PIPE HANGER
DOUBLE CHECK BACKFLOW ASSEMBLY
REDUCED PRESSURE ZONE BACKFLOW ASSEMBLY
3-WAY CONTROL VALVE (ELECTRIC)
ANCHOR
CAP
PIPE DROP
PIPE RISE
UNION OR FLANGE CONNECTION
TOP CONNECTION, 45° OR 90°
BOTTOM CONNECTION, 45° OR 90°
SIDE CONNECTION
CAPPED OUTLET
DIRECTION OF FLOW
CONCENTRIC REDUCER OR INCREASER
ECCENTRIC REDUCER
TYP. TYPICAL ALL INSTANCES
VARIABLE FREQUENCY DRIVEVFD
GENERAL NOTES
1. VERIFY JOB SITE CONDITIONS AND DIMENSIONS BEFORE BEGINNING WORK. PLANS ARE SCHEMATIC IN NATURE. LAYOUT IS BASED ON
BEST AVAILABLE INFORMATION. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS.
2. NO PIPING, DUCTWORK, ETC. SHALL PENETRATE STRUCTURAL MEMBERS.
3. PROVIDE MISCELLANEOUS CUTTING, PATCHING AND REPAIRING OF FINISHES, ROOF, WALLS, ETC., AS REQUIRED TO ACCOMMODATE THE
NEW WORK.
4. CONTRACTOR IS TO PATCH ANY OPENINGS IN CORRIDORS REQUIRED TO BE CONSTRUCTED TO LIMIT THE TRANSFER OF SMOKE AND IN SMOKE BARRIERS AS REQUIRED TO MEET CODE REQUIREMENTS. SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS.
5. REMOVE ALL EXISTING EQUIPMENT, DUCTWORK AND PIPING THAT IS NOT REQUIRED FOR A WORKING INSTALLATION.
6. COORDINATE ALL WORK WITH OTHER TRADES PRIOR TO INSTALLATION.
7. UNLESS OTHERWISE INDICATED, INSTALL ALL SPACE THERMOSTATS AND OTHER OCCUPANT ADJUSTABLE CONTROL DEVICES SAME HEIGHT AS ADJACENT LIGHT SWITCHES, BUT IN NO CASE HIGHER THAN 48 INCHES ABOVE FINISHED FLOOR PER ABA REQUIREMENTS.
8. ALL CUTTING AND PATCHING SHALL BE CLOSELY COORDINATED BY THE CONTRACTOR.
9. COORDINATE ROUTING OF PLUMBING, AND HVAC PIPING WITH DUCTWORK, LIGHTS, ARCHITECTURAL CEILING AND STRUCTURAL ELEMENTS. PIPING SHALL RISE AND DROP, JOG OR OFFSET AS REQUIRED TO AVOID CONFLICTS. DUCTWORK SHALL TAKE PRECEDENCE OVER ALL PIPING, EXCEPT WHERE GRADE MUST BE MAINTAINED FOR DRAINAGE. REWORK OF INSTALLED WORK TO RESOLVE CONFLICTS RISING FROM LACK OF COORDINATION SHALL NOT JUSTIFY AN INCREASE IN THE CONTRACT AMOUNT.
10. ALL DIFFUSERS ARE 4-WAY BLOW UNLESS INDICATED OTHERWISE ON THE DRAWINGS.
11. FLEXIBLE DUCTWORK IS ALLOWED ON RUNOUTS TO SUPPLY DIFFUSERS ONLY. UTILIZE ONLY ABOVE LAY-IN ACCESSIBLE CEILINGS. DO NOT INSTALL FLEX DUCT ABOVE HARD CEILINGS OR WHERE EXPOSED. A MAXIMUM LENGTH OF 5'-0" MAY BE USED AT EACH CONNECTION.
12. SEAL DUCTWORK PER SPECIFICATIONS. SEAL TO SMACNA SEAL CLASS A:
TYPE OF DUCT APPLY TO JOINTS
EXHAUST DUCT (ROUND OR RECT) TRANSVERSE AND LONGITUDINAL
LOW VELOCITY SUPPLY AND RETURN (RECT) TRANSVERSE AND LONGITUDINAL
LOW VELOCITY SUPPLY (ROUND) TRANSVERSE AND LONGITUDINAL
13. INSTALL BALANCE DAMPER WITH STANDOFF AND LOCKING QUADRANT IN AN ACCESSIBLE LOCATION AT EACH RUNOUT TO SUPPLY DIFFUSERS, EXHAUST GRILLES, AND RETURN GRILLES WHERE AIRFLOW IS INDICATED, OR AS INDICATED OTHERWISE.
14. ALL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE FIRE STOPPED BY THE TRADE MAKING THE PENETRATION. REFER TO
ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR REQUIREMENTS.
15. DO NOT ROUTE PIPING OR DUCTWORK OVER ELECTRICAL PANELS OR EQUIPMENT. PIPING OR DUCTWORK SHALL NOT BE ROUTED THROUGH ELECTRICAL ROOMS, TELECOM ROOMS OR ELEVATOR EQUIPMENT ROOMS UNLESS SPECIFICALLY SERVING THAT ROOM.
PROVIDE WATERTIGHT DRIP PAN WITH DRAIN TO NEAREST APPROVED RECEPTOR WHERE REQUIRED.
16. CONTRACTOR SHALL COORDINATE SIZE AND LOCATION OF ACCESS DOORS IN CONSTRUCTION REQUIRED FOR ACCESS TO MECHANICAL
AND PLUMBING EQUIPMENT.
17. CONTRACTOR SHALL COORDINATE SIZE AND LOCATION OF MECHANICAL EQUIPMENT PADS.
18. ALL WORK IS TO CONFORM WITH APPLICABLE CODES AND STANDARDS.
19. DUCT SIZES SHOWN ARE ACTUAL INSIDE CLEAR DIMENSIONS. INCREASE SHEET METAL DIMENSIONS AS REQUIRED TO ACCOMMODATE
DUCT LINER WHERE LINER IS SPECIFIED.
20. ALL EQUIPMENT SUPPORT STANDS SHALL BE PRIMED AND PAINTED.
21. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF ALL CEILING MOUNTED AIR DISTRIBUTION DEVICES.
22. PAINT INSIDE OF DUCTWORK BLACK ANYWHERE VISIBLE THROUGH FACE OF GRILLE OR DIFFUSER.
23. WHERE HYDRONIC RUNOUT SIZES ARE NOT INDICATED, SIZE PER THE FOLLOWING:
UP TO 1 GPM - 1/2"; UP TO 3 GPM - 3/4"; UP TO 6 GPM - 1"; UP TO 10 GPM - 1-1/4"; UP TO 17 GPM - 1-1/2"
24. HYDRONIC PIPING SHALL BE MAINTAINED FULL SIZE UP TO COIL CONNECTIONS. SHUT-OFF VALVES, STRAINERS, BALANCE VALVES, ETC.
WILL NOT BE ALLOWED TO REDUCE FROM LINE/RUNOUT SIZE. CONTROL VALVES MAY BE DOWN SIZED FOR FLOW RATE, NOT TO EXCEED 4
PSIG PRESSURE DROP AT DESIGN FLOW.
25. CONTRACTOR SHALL FURNISH AND INSTALL ALL LOW VOLTAGE WIRING AND ASSOCIATED CONDUIT REQUIRED FOR MECHANICAL CONTROL SYSTEM. WIRING SHALL BE IN CONDUIT INSIDE WALLS, IN ROOMS WITH EXPOSED CEILINGS, AND ABOVE HARD CEILINGS. LINE VOLTAGE WIRING AND ASSOCIATED CONDUIT SHALL BE PROVIDED AND INSTALLED BY CONTRACTOR. CONTROL SYSTEM SHALL BE INSTALLED IN
ACCORDANCE WITH SPECIFICATIONS.
26. CONTRACTOR SHALL COORDINATE ACCESS TO EQUIPMENT AND VALVES INSTALLED ABOVE 'HARD' CEILINGS AND IN MASONRY CHASES.
PROVIDE LOCKING ACCESS DOORS FOR INSTALLATION BY CONTRACTOR AS REQUIRED TO SERVICE CONCEALED DAMPERS, VALVES AND EQUIPMENT. CEILING ACCESS DOORS FOR FIRE DAMPERS, SMOKE DAMPERS AND FIRE SMOKE DAMPERS FURNISHED AND INSTALLED BY
CONTRACTOR.
27. CONTRACTOR TO INSTALL TEMPORARY FILTERS OVER ALL RETURN AND EXHAUST GRILLES IN WORK AREA DURING CONSTRUCTION.
28. THESE DRAWINGS ARE ACCOMPANIED BY SPECIFICATIONS. REFER TO SPECIFICATIONS FOR FURTHER INFORMATION.
29. EQUIPMENT THAT REQUIRES MAINTENANCE SHALL BE LOCATED A MINIMUM OF 10'-0" FROM THE BUILDING ROOF EDGE WHERE REQUIRED
BY CODE.
DOMESTIC COLD WATER LINE (CW)
ABOVE FLOOR WASTE LINE (W)
BELOW WASTE LINE (W)
DOMESTIC HOT WATER LINE (HW)
HOT WATER RECIRC LINE (HWC)
PLUMBING VENT LINE (V)
F FIRE PROTECTION LINE (F)
CD COOLING COIL CONDENSATE DRAIN LINE (CD)
WCO
CO
CO
CO
FLOOR DRAIN
PLUMBING FIXTURE CALLOUT
WATER HAMMER ARRESTOR - PDI SIZE
FD
P-#
WHA#
HOSE BIBBHB
F FLOW LINE ELEVATION
DOMESTIC HOT WATER PUMPDHWP
VTR VENT THROUGH ROOF
L
WALL CLEANOUT
CLEANOUT
2-WAY CLEANOUT
END OF LINE CLEANOUT
G NATURAL GAS LINE (G)
WH-# WATER HEATER CALLOUT
WALL HYDRANTWH
FS FLOOR SINK
POLYVINYL CHLORIDE PIPEPVC
AFMS AIRFLOW MEASURING STATION
SEISMIC
1. REFERENCE SPECIFICATION 13 48 00.00 10 FOR SEISMIC
BRACING REQUIRMENTS.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
P R
O F
E S
S
IO
N A
L E
N G
IN
E
E R
IN
G
C O
N S
U L T
A N
T S
P
.A
S
T O
P E
K A
W
IC
H
IT
A K
S
C P
R Z
Y G
O D
A
M-001
M E
C H
A N
IC
A
L C
O V
E R
S H
E E
T
J O
IN
T
B A
S E
L E
W
IS
-M C
C H
O R
D W
A
S E
A T
T L E
D
IS
T R
IC
T
E
M
A R
G
IN
A L W
A Y
S O
U T
H B
L D
G
S E
A T
T L E
W
A
-2
D E
W
IN
G
M N
E W
M A
N
C W
A P
E L H
O R
S T
A
U G
U S
T
T B
D
T B
D
RTA DESIGN SUBMITTAL
R E
P A
IR
B
U
IL
D
IN
G
D E
S
IG
N C
O N
S T
R U
C T
IO
N
P K
G N
O C
E C
E
08/10/2021
C1 C2 C3 C4 C5 C6 C7 C8
C3.5 C4.5 C5.5 C6.5 C7.5C2.5
CB
CC
A1
A2
A3
A4
A5
A6
A7
A8
A2.5
A3.5
A4.5
A5.5
A6.5
A7.5
B1
B2
B4
B5
B3
111 (TYP.)
(TYP.)
(TYP.)
(TYP.)
1111(TYP.)
1111 (TYP.)
(TYP.)
(TYP.)
2 (TYP.)
2(TYP.)
(TYP.)
(TYP.)
33 45
A
B
C
PLUMBING DEMO NOTES
1. FIELD VERIFY ALL EXISTING CONDITIONS
PRIOR TO BEGINNING WORK. BRING ANY
DISCREPANCIES FROM THE DRAWINGS
AND NOTES TO THE COR IMMEDIATELY.
2. REMOVE ALL EXISTING PLUMBING PIPING
INCLUDING THE FOLLOWING: DOMESTIC
COLD WATER PIPING, HOT WATER PIPING,
HOT WATER RECIRCULATION PIPING,
NATURAL GAS PIPING, SANITARY WASTE
AND VENT PIPING, AND PRIMARY AND
OVERFLOW RAIN LEADER PIPING.
REMOVE ALL ASSOCIATED INSULATION
AND HANGERS.
3. CUTTING OF STRUCTURAL MEMBERS IS
NOT ALLOWED.
4. REMOVE EXISTING EQUIPMENT WHETHER
SHOWN OR NOT.
5. REMOVE ALL ABOVE GRADE PIPING.
REMOVE EXISTING ABANDONED BELOW
GRADE PIPING IN CONFLICT WITH
INSTALLATION OF NEW PIPING BELOW
SLAB. CAP ALL ABANDONED PIPING
BELOW FIRST FLOOR SLAB.
CONTRACTOR TO REMOVE SLAB AS
REQUIRED TO CAP EXISTING PIPING
BELOW GRADE AND FOR INSTALLATION
OF NEW PIPING. REFERENCE
ARCHITECTURAL DRAWINGS AND
STRUCTURAL DRAWINGS SB112 AND
SB113 AND DETAILS A4/S-501 AND A4/S-502
FOR PATCHING OR REPLACEMENT OF
EXISTING SLAB ON GRADE.
6. REMOVE ALL EXISTING PLUMBING
FIXTURES, CARRIERS AND ASSOCIATED
PIPING.
7. ALL EXISTING DUCTS, PIPING, AND
EQUIPMENT, ETC., SHALL BE REMOVED.
ALL ENDS OF DISCONTINUED PIPING AND
DUCTS SHALL BE CAPPED IN THE
NEAREST WALL, CEILING, OR FLOOR SO
THAT THEY ARE COMPLETELY
CONCEALED. OPENINGS LEFT IN WALLS,
FLOORS, CEILINGS, ETC. WHERE
EQUIPMENT, PIPE AND DUCTS, ETC. ARE
REMOVED AND NOT REPLACED, SHALL BE
PATCHED NEATLY WITH SIMILAR
MATERIAL TO ADJACENT CONSTRUCTION.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
P R
O F
E S
S
IO
N A
L E
N G
IN
E
E R
IN
G
C O
N S
U L T
A N
T S
P
.A
S
T O
P E
K A
W
IC
H
IT
A K
S
C P
R Z
Y G
O D
A
PD101
P L U
M B
IN
G
D E
M O
L
IT
IO
N
P L A
N
F
IR
S T
F L O
O R
J O
IN
T
B A
S E
L E
W
IS
-M C
C H
O R
D W
A
S E
A T
T L E
D
IS
T R
IC
T
E
M
A R
G
IN
A L W
A Y
S O
U T
H B
L D
G
S E
A T
T L E
W
A
-2
D E
W
IN
G
M N
E W
M A
N
C W
A P
E L H
O R
S T
A
U G
U S
T
T B
D
T B
D
RTA DESIGN SUBMITTAL
R E
P A
IR
B
U
IL
D
IN
G
D E
S
IG
N C
O N
S T
R U
C T
IO
N
P K
G N
O C
E C
E
1/16" = 1'-0"A3
PLUMBING DEMOLITION PLAN - OVERALL FIRST FLOOR
PLAN NORTH
0 8' 16' 32'
SCALE: 1/16" = 1'
DEMOLITION NOTES
1 REMOVE ALL EXISTING PLUMBING
FIXTURES AND ALL ASSOCIATED PIPING.
2 REMOVE ALL EXISTING PIPING.
3 REMOVE EXISTING WATER HEATERS
AND ALL ASSOCIATED PIPING,
CONTROLS, ELECTRICAL AND FLUES.
4 REMOVE EXISTING STORAGE TANK AND
ASSOCIATED PIPING, AND SUPPORTS.
5 REMOVE EXISTING BACKUP DIESEL FUEL
SYSTEM INCLUDING DAY TANK, PIPING,
PUMPS, CONTROLS, AND ELECTRICAL.
6 REMOVE ALL ABOVE GRADE RAIN
LEADER PIPING. CAP AND ABANDON ALL
RAIN LEADER PIPING BELOW FIRST
FLOOR SLAB. PATCH FLOOR TO MATCH
ADJACENT SURFACE.
7 REMOVE ALL RAIN LEADER PIPING.
REMOVE DOWNSPOUT NOZZLE AT
BUILDING EXTERIOR. PATCH WALL TO
MATCH ADJACENT SURFACE.
8 REMOVE EXISTING FREEZE-PROOF
WALL HYDRANT AND ASSOCIATED
PIPING. PATCH WALL TO MATCH
ADJACENT SURFACE.
CB
CC
A1
A2
A3
A4
A5
A6
A7
A8
A2.5
A3.5
A4.5
A5.5
A6.5
A7.5
B1
B2
B4
B5
B3
111 (TYP.)
111 (TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
A
B
C
PLUMBING DEMO NOTES
1. FIELD VERIFY ALL EXISTING CONDITIONS
PRIOR TO BEGINNING WORK. BRING ANY
DISCREPANCIES FROM THE DRAWINGS
AND NOTES TO THE COR IMMEDIATELY.
2. REMOVE ALL EXISTING PLUMBING PIPING
INCLUDING THE FOLLOWING: DOMESTIC
COLD WATER PIPING, HOT WATER PIPING,
HOT WATER RECIRCULATION PIPING,
NATURAL GAS PIPING, SANITARY WASTE
AND VENT PIPING, AND PRIMARY AND
OVERFLOW RAIN LEADER PIPING.
REMOVE ALL ASSOCIATED INSULATION
AND HANGERS.
3. CUTTING OF STRUCTURAL MEMBERS IS
NOT ALLOWED.
4. REMOVE EXISTING EQUIPMENT
WHETHER SHOWN OR NOT.
5. REMOVE ALL ABOVE GRADE PIPING.
REMOVE BELOW GRADE PIPING IF IT IS IN
THE WAY OF NEW PIPING INSTALLATION
BELOW SLAB. CAP ALL ABANDONED
PIPING BELOW FIRST FLOOR SLAB.
PATCH FLOOR TO MATCH ADJACENT
SURFACE. REFER TO STRUCTURAL
DRAWINGS FOR HOLLOW CORE REPAIR
DETAILS.
6. REMOVE ALL EXISTING PLUMBING
FIXTURES, CARRIERS AND ASSOCIATED
PIPING.
7. ALL EXISTING DUCTS, PIPING, AND
EQUIPMENT, ETC., SHALL BE REMOVED.
ALL ENDS OF DISCONTINUED PIPING AND
DUCTS SHALL BE CAPPED IN THE
NEAREST WALL, CEILING, OR FLOOR SO
THAT THEY ARE COMPLETELY
CONCEALED. OPENINGS LEFT IN WALLS,
FLOORS, CEILINGS, ETC. WHERE
EQUIPMENT, PIPE AND DUCTS, ETC. ARE
REMOVED AND NOT REPLACED, SHALL
BE PATCHED NEATLY WITH SIMILAR
MATERIAL TO ADJACENT
CONSTRUCTION.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
P R
O F
E S
S
IO
N A
L E
N G
IN
E
E R
IN
G
C O
N S
U L T
A N
T S
P
.A
S
T O
P E
K A
W
IC
H
IT
A K
S
C P
R Z
Y G
O D
A
PD111
P L U
M B
IN
G
D E
M O
L
IT
IO
N
P L A
N
S E
C O
N D
F L O
O R
J O
IN
T
B A
S E
L E
W
IS
-M C
C H
O R
D W
A
S E
A T
T L E
D
IS
T R
IC
T
E
M
A R
G
IN
A L W
A Y
S O
U T
H B
L D
G
S E
A T
T L E
W
A
-2
D E
W
IN
G
M N
E W
M A
N
C W
A P
E L H
O R
S T
A
U G
U S
T
T B
D
T B
D
RTA DESIGN SUBMITTAL
R E
P A
IR
B
U
IL
D
IN
G
D E
S
IG
N C
O N
S T
R U
C T
IO
N
P K
G N
O C
E C
E
PLAN NORTH
0 8' 16' 32'
SCALE: 1/16" = 1'
1/16" = 1'-0"A3
PLUMBING DEMOLITION PLAN - OVERALL SECOND FLOOR
DEMOLITION NOTES
1 REMOVE ALL EXISTING PLUMBING
FIXTURES AND ALL ASSOCIATED PIPING.
2 REMOVE ALL EXISTING PIPING.
CB
CC
A1
A2
A3
A4
A5
A6
A7
A8
A2.5
A3.5
A4.5
A5.5
A6.5
A7.5
B1
B2
B4
B5
B3
(TYP.)
(TYP.)
(TYP.)
(TYP.)
3(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
3 (TYP.)
2 (TYP.)
3 (TYP.)
3(TYP.)
A
B
C
PLUMBING DEMO NOTES
1. FIELD VERIFY ALL EXISTING CONDITIONS
PRIOR TO BEGINNING WORK. BRING ANY
DISCREPANCIES FROM THE DRAWINGS
AND NOTES TO THE COR IMMEDIATELY.
2. REMOVE ALL EXISTING PLUMBING PIPING
INCLUDING THE FOLLOWING: DOMESTIC
COLD WATER PIPING, HOT WATER PIPING,
HOT WATER RECIRCULATION PIPING,
NATURAL GAS PIPING, SANITARY WASTE
AND VENT PIPING, AND PRIMARY AND
OVERFLOW RAIN LEADER PIPING.
REMOVE ALL ASSOCIATED INSULATION
AND HANGERS.
3. CUTTING OF STRUCTURAL MEMBERS IS
NOT ALLOWED.
4. REMOVE EXISTING EQUIPMENT
WHETHER SHOWN OR NOT.
5. REMOVE ALL ABOVE GRADE PIPING.
REMOVE BELOW GRADE PIPING IF IT IS IN
THE WAY OF NEW PIPING INSTALLATION
BELOW SLAB. CAP ALL ABANDONED
PIPING BELOW FIRST FLOOR SLAB.
PATCH FLOOR TO MATCH ADJACENT
SURFACE. REFER TO STRUCTURAL
DRAWINGS FOR HOLLOW CORE REPAIR
DETAILS.
6. REMOVE ALL EXISTING PLUMBING
FIXTURES, CARRIERS AND ASSOCIATED
PIPING.
7. ALL EXISTING DUCTS, PIPING, AND
EQUIPMENT, ETC., SHALL BE REMOVED.
ALL ENDS OF DISCONTINUED PIPING AND
DUCTS SHALL BE CAPPED IN THE
NEAREST WALL, CEILING, OR FLOOR SO
THAT THEY ARE COMPLETELY
CONCEALED. OPENINGS LEFT IN WALLS,
FLOORS, CEILINGS, ETC. WHERE
EQUIPMENT, PIPE AND DUCTS, ETC. ARE
REMOVED AND NOT REPLACED, SHALL
BE PATCHED NEATLY WITH SIMILAR
MATERIAL TO ADJACENT
CONSTRUCTION.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
P R
O F
E S
S
IO
N A
L E
N G
IN
E
E R
IN
G
C O
N S
U L T
A N
T S
P
.A
S
T O
P E
K A
W
IC
H
IT
A K
S
C P
R Z
Y G
O D
A
PD121
P L U
M B
IN
G
D E
M O
L
IT
IO
N
P L A
N
T H
IR
D
F L O
O R
J O
IN
T
B A
S E
L E
W
IS
-M C
C H
O R
D W
A
S E
A T
T L E
D
IS
T R
IC
T
E
M
A R
G
IN
A L W
A Y
S O
U T
H B
L D
G
S E
A T
T L E
W
A
-2
D E
W
IN
G
M N
E W
M A
N
C W
A P
E L H
O R
S T
A
U G
U S
T
T B
D
T B
D
RTA DESIGN SUBMITTAL
R E
P A
IR
B
U
IL
D
IN
G
D E
S
IG
N C
O N
S T
R U
C T
IO
N
P K
G N
O C
E C
E
PLAN NORTH
0 8' 16' 32'
SCALE: 1/16" = 1'
1/16" = 1'-0"A3
PLUMBING DEMOLITION PLAN - OVERALL THIRD FLOOR
DEMOLITION NOTES
1 REMOVE ALL EXISTING PLUMBING
FIXTURES AND ALL ASSOCIATED PIPING.
2 REMOVE ALL EXISTING PIPING.
3 REMOVE EXISTING RAINLEADER PIPING.
CB
CC
A1
A2
A3
A4
A5
A6
A7
A8
A2.5
A3.5
A4.5
A5.5
A6.5
A7.5
B1
B2
B4
B5
B3
A
/ P P
A
/ P P
A4 / PP102
A2 / PP103
SLEEPING
SLEEPING
BATHROOM
BATH
UNIT
124CLOSET
CLOSET
MECH.
MECH
JAN
MECH
SLEEPING108
SLEEPING
X
UNIT
SLEEPING108
SLEEPING
Z
MECH
NEC COMM
MAIL ACCESS ROOM
UNISEX
LOBBY
CQ
102A
JAN
MUDROOM
152A
MUDROOM
FIRE RISER / UTILITY
NEC COMM
SWITCHGEAR
ELEC / COMMERCIAL TELECOMM
UTILITY
JAN
A
B
C
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
P R
O F
E S
S
IO
N A
L E
N G
IN
E
E R
IN
G
C O
N S
U L T
A N
T S
P
.A
S
T O
P E
K A
W
IC
H
IT
A K
S
C P
R Z
Y G
O D
A
PP101
O V
E R
A L L F
IR
S
T F
L O
O R
P L U
M B
IN
G
P L A
N
J O
IN
T
B A
S E
L E
W
IS
-M C
C H
O R
D W
A
S E
A T
T L E
D
IS
T R
IC
T
E
M
A R
G
IN
A L W
A Y
S O
U T
H B
L D
G
S E
A T
T L E
W
A
-2
D E
W
IN
G
M N
E W
M A
N
C W
A P
E L H
O R
S T
A
U G
U S
T
T B
D
T B
D
RTA DESIGN SUBMITTAL
R E
P A
IR
B
U
IL
D
IN
G
D E
S
IG
N C
O N
S T
R U
C T
IO
N
P K
G N
O C
E C
E
1/16" = 1'-0"A4
OVERALL FIRST FLOOR PLUMBING PLAN
PLAN NORTH
0 8' 16' 32'
SCALE: 1/16" = 1'
C1 C2 C3 C4
C3.5C2.5
A1
A2
A2.5
B1
B2
B4
B5
B3
A
/ P P
A2 / PP103
UNIT
UNIT
NEC COMM
MECH
FIRE ALARM
105MAIL ACCESS ROOM
UNISEX
LOBBY
MUDROOM
152A
JAN
151MUDROOM
FOYER
FIRE RISER / UTILITY
NEC COMM
SWITCHGEAR
ELEC / COMMERCIAL TELECOMM
DOMESTIC HOT AND COLD WATER
PIPING MAINS ROUTED IN CORRIDOR.
DOMESTIC HOT AND COLD
WATER PIPING MAINS
ROUTED IN CORRIDOR.
P3.2
P1.2
DOMESTIC WATER ENTRANCE
LOCATED ON SHEET PP103.
P4.1
P-401 A1
P-401 A1
P-401 A5
P-401 A1
P-401 A1
P6.1
P6.1
2"FD
2"FD
MSS-101
MSS-102
6"CO
2"FD
2"FD
2"FD
MSS-103
GAS SERVICE
BELOW GRADE
3"3"CW
2 1/2"2 1/2"HW
2 1/2"2 1/2"CW 2"2"HW 2 1/2"2 1/2"CW
2"2"HW
3"3"CW
2 1/2"2 1/2"HW
3"3"CW
2"2"HW
3"3"CW
2 1/2"2 1/2"HW
6"6"W
6"CO
4"CO
4"4"W
4"4"W
2"2"HW
SIMILAR
SIMILAR
SIMILAR
SIMILAR
2"CW AND 1-1/4"HW
UP TO 2ND FLOOR.
2"CW & 1"HW
UP TO 2ND FLOOR.
1 1/4"CW & 1"HW
UP TO 2ND FLOOR.
1"H&CW, 3"W UP.
1/2"CW, 1 1/2"V
AND 2"W FROM
2ND FLOOR.
3/4"3/4"CW
2"2"W
2"V UP TO ATTIC.
SEE SHEET
MH131 FOR CONT.4"WCO
2"W DOWN IN WALL
TO BELOW GRADE.
3"3"W
4"W DOWN IN CHASE
TO BELOW GRADE.
1 1/2"V UP TO ATTIC. SEE
SHEET MH131 FOR CONT.
2"V UP TO ATTIC. SEE
SHEET MH131 FOR CONT.
2 1/2"V UP TO ATTIC. SEE
SHEET MH131 FOR CONT.
4"FS
4"CO
4"CO
4"CO
FIRE ALARM
153A
STORAGE
104B
UTILITY
104A
UNIT
STAIR C
C1
UNIT
UNIT
STAIR B
B1
4"CO
6"CO
2"2"W
2-WAY CO
6"6"W
4"4" W
4"4" W
6"6"W
CU-201
CU-101
CU-301
CO
3/4"3/4"CD
CU-202 CU-302CU-102
UH-106 3
CO
CO
CO
CU-103
CU-203
CU-303
4"W DOWN IN CHASE.
CONNECT TO 4"W
BELOW GRADE. 4"4"W
4"CO
2"2"W
WHA-A
4"CO
6" SANITARY SEWER
LINE. REFER TO CIVIL
FOR CONTINUATION.
1 1/4"CW&HW
TO MUDROOM.
P-403 A7
2"2"V
ABOVE FLOOR
WASTE PIPING.
ABOVE FLOOR
WASTE PIPING.
P-403 A1
2"W FROM
FD ABOVE
2"2"W
2"W UP
2"W UP
P-401 D1
P-401 E5
P-401 D1
P-401 D1
P-401 D1
2"CO
3/4"CD TO SPILL TO GRADE.
FCU-112
1 1/4"1 1/4"CW
1/2"1/2"HW
SHUT OFF VALVES (TYP)
2"W UP TO FD
3/4"CD FROM FCU-224
ON 2ND FLOOR.
2"W UP TO P4.1
1 1/4"CW & HW
UP TO 2ND FLOOR.
P-403 A4
3"3" W
2-WAY CO
1"1"CW 9
A
B
C
PLUMBING GENERAL NOTES
1. REFERENCE PLUMBING FIXTURE
SCHEDULE ON SHEET P-601 FOR PIPING
RUN OUT AND CONNECTION SIZES.
2. FOR ALL NEW PENETRATIONS IN PRECAST
HOLLOW CORE SLABS, THE EXISTING
REINFORCING MUST BE LOCATED BY NON-
DESTRUCTIVE TESTING METHODS PRIOR
TO ANY CUTTING OR CORE DRILLING.
REFER TO DETAIL F4/S-501 FOR
APPROVED OPENING LOCATIONS.
3. ALL FLOOR DRAINS LOCATED IN
BATHROOMS SHALL HAVE TRAP GUARDS
INSTALLED PER DETAIL F1/P-501.
4. CONTRACTOR TO REMOVE SLAB AS
REQUIRED TO INSTALL BELOW GRADE
PIPING. REFERENCE ARCHITECTURAL
DRAWINGS AND STRUCTURAL DRAWINGS
SB112 AND SB113 AND DETAILS A4/S-501
AND A4/S-502 FOR PATCHING OR
REPLACEMENT OF EXISTING SLAB ON
GRADE.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
P R
O F
E S
S
IO
N A
L E
N G
IN
E
E R
IN
G
C O
N S
U L T
A N
T S
P
.A
S
T O
P E
K A
W
IC
H
IT
A K
S
C P
R Z
Y G
O D
A
PP102
F
IR
S T
F L O
O R
A R
E A
B P
L U
M B
IN
G
P L A
N
J O
IN
T
B A
S E
L E
W
IS
-M C
C H
O R
D W
A
S E
A T
T L E
D
IS
T R
IC
T
E
M
A R
G
IN
A L W
A Y
S O
U T
H B
L D
G
S E
A T
T L E
W
A
-2
D E
W
IN
G
M N
E W
M A
N
C W
A P
E L H
O R
S T
A
U G
U S
T
T B
D
T B
D
RTA DESIGN SUBMITTAL
R E
P A
IR
B
U
IL
D
IN
G
D E
S
IG
N C
O N
S T
R U
C T
IO
N
P K
G N
O C
E C
E
1/8" = 1'-0"A4
PLUMBING PLAN - FIRST FLOOR AREA-B
PLAN NORTH
0 4' 8' 16'
SCALE: 1/8" = 1'
PLAN NOTES
1 DOMESTIC HOT WATER RECIRCULATION
PIPING UP TO 3RD FLOOR.
2 SANITARY WASTE PIPING FROM 2ND
AND 3RD FLOOR PLUMBING FIXTURES.
3 3/4"CD ROUTED TO FLOOR DRAIN
LOCATED IN MECHANICAL CLOSET.
TERMINATE CONDENSATE PIPING
ABOVE FLOOR DRAIN VIA AIR GAP.
4 1"CW TO POST HYDRANTS AT
BOOTWASH. INSTALL TWO POST
HYDRANTS P9.2 AT BOOTWASH. SEE
BOOTWASH DETAIL ON STRUCTURAL
SHEET C4/S-502 AND CIVIL SHEET CS101
FOR ADDITIONAL INFORMATION.
REFERENCE CIVIL SITE PLANS FOR
LOCATION OF BOOTWASH.
5 3/4"CD ROUTED TO FLOOR DRAIN.
TERMINATE CONDENSATE PIPING
ABOVE FLOOR DRAIN VIA AIR GAP.
6 1/2"CW TO TRAP PRIMER. REFER TO
DETAIL C1/P-501.
7 FLOOR DRAINS IN MECHANICAL ROOM
107 AND UTILITY 104A SHALL HAVE TRAP
GUARD INSERT INSTALLED PER DETAIL
F1/P-501.
8 3"W TO BOOTWASH. SEE STRUCTURAL
DETAIL C4/S-502 AND CIVIL SHEET CS101
FOR CONNECTION REQUIREMENTS AT
BOOTWASH.
9 EXISTING BUILDING SEISMIC JOINT,
REFERENCE STRUCTURAL. PROVIDE
FLEXIBLE JOINTS IN HVAC, PLUMBING
AND PIPING SYSTEMS PER
SPECIFICATIONS SECTION 13 48 00.00 10.
A
B
C
A3
A4
A5
A6
A7
A8
A2.5
A3.5
A4.5
A5.5
A6.5
A7.5
A4 / PP102
ELEC / COMMERCIAL TELECOMM
UTILITY
JAN
4" DOMESTIC COLD WATER LINE.
REFER TO CIVIL FOR CONTINUATION.
DOMESTIC HOT AND COLD WATER
PIPING MAINS ROUTED IN CORRIDOR.
P-401 A1
P-401 A1
P-401 A1
P-401 A1
P-401 A1
P-401 A1
P-401 A5
2"FD
P4.1
SIMILAR
SIMILAR
SIMILAR
3"3"CW
2"2"HW
3"3"CW
4"4"CW
1 1/2"1 1/2"HW
1"1"HW
2"2"HW
4"4" W
6"6" W
4"4" W
3"WCO
1"CW&HW UP. REFER TO DETAIL D7/P-901
FOR ADDITIONAL PIPE SIZES.
4"4"CW
4"4"W
P-401 D1
P-401 D1
P-401 D1
P-401 D1
P-401 D1
P-401 E5
P-401 A1
P9.1
6" SANITARY SEWER
LINE. REFER TO CIVIL
FOR CONTINUATION.
2-WAY CLEANOUT
FCU-101
4"CO
6"CO
6"6"W
6"CO
6"6"W
6"6"W
4"4"W
1/2"CW DOWN TO TRAP PRIMER.
C4 C5 C6 C7 C8
C4.5 C5.5 C6.5 C7.5
CB
CC
A
/ P P
UNIT
MECH.
MECH
CLOSET
CLOSET
SLEEPING
SLEEPING
BATHROOM
BATH
JAN
MECH
P-401 A5
P-401 A1
DOMESTIC HOT AND COLD WATER
PIPING MAINS ROUTED IN CORRIDOR.
P-401 A1
P-401 A1
P-401 A1
P4.1
2"FD
2"FD
4"CO
SIMILAR
SIMILAR
1"1"CW
1"1"HW
2 1/2"2 1/2"CW
2"2"HW
6"6"W
1 1/2"1 1/2"HW
4"4"W
2"2"CW
6"6"W
2"2" W
REFER TO DETAIL D7/P-901
FOR ADDITIONAL PIPE SIZES.
(SIMILAR)
P-401 D1
P-401 D1
P-401 E5
P-401 D1
P-401 D1
P9.1
1 1/2"V UP
2"W FROM THIRD
FLOOR MECH ROOM
FCU-123 3
1/2"CW DOWN TO TRAP PRIMER.
PLUMBING GENERAL NOTES
1. REFERENCE PLUMBING FIXTURE
SCHEDULE ON SHEET P-601 FOR PIPING
RUN OUT AND CONNECTION SIZES.
2. FOR ALL NEW PENETRATIONS IN PRECAST
HOLLOW CORE SLABS, THE EXISTING
REINFORCING MUST BE LOCATED BY NON-
DESTRUCTIVE TESTING METHODS PRIOR
TO ANY CUTTING OR CORE DRILLING.
REFER TO DETAIL F4/S-501 FOR
APPROVED OPENING LOCATIONS.
3. ALL FLOOR DRAINS LOCATED IN
BATHROOMS SHALL HAVE TRAP GUARDS
INSTALLED PER DETAIL F1/P-501.
4. CONTRACTOR TO REMOVE SLAB AS
REQUIRED TO INSTALL BELOW GRADE
PIPING. REFERENCE ARCHITECTURAL
DRAWINGS AND STRUCTURAL DRAWINGS
SB112 AND SB113 AND DETAILS A4/S-501
AND A4/S-502 FOR PATCHING OR
REPLACEMENT OF EXISTING SLAB ON
GRADE.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
P R
O F
E S
S
IO
N A
L E
N G
IN
E
E R
IN
G
C O
N S
U L T
A N
T S
P
.A
S
T O
P E
K A
W
IC
H
IT
A K
S
C P
R Z
Y G
O D
A
PP103
F
IR
S T
F L O
O R
A R
E A
A A
N D
C P
L U
M B
IN
G
P L A
N
J O
IN
T
B A
S E
L E
W
IS
-M C
C H
O R
D W
A
S E
A T
T L E
D
IS
T R
IC
T
E
M
A R
G
IN
A L W
A Y
S O
U T
H B
L D
G
S E
A T
T L E
W
A
-2
D E
W
IN
G
M N
E W
M A
N
C W
A P
E L H
O R
S T
A
U G
U S
T
T B
D
T B
D
RTA DESIGN SUBMITTAL
R E
P A
IR
B
U
IL
D
IN
G
D E
S
IG
N C
O N
S T
R U
C T
IO
N
P K
G N
O C
E C
E
PLAN NORTH
0 4' 8' 16'
SCALE: 1/8" = 1'
1/8" = 1'-0"A2
PLUMBING PLAN - FIRST FLOOR AREA-A
1/8" = 1'-0"A6
PLUMBING PLAN - FIRST FLOOR AREA-C
PLAN NOTES
1 SHUT-OFF VALVE, WYE STRAINER
UPSTREAM OF REDUCED PRESSURE
BACKFLOW ASSEMBLY, WATER METER,
AND REDUCED PRESSURE BACKFLOW
PREVENTER. ROUTE PIPING FROM
BLOW-OFF OUTLET OF STRAINER TO
FIXTURE P9.1.
2 3/4"CD ROUTED TO MOP SINK ON FLOOR
BELOW. TERMINATE CONDENSATE
PIPING ABOVE MOP SINK VIA AIR GAP.
3 ROUTE CONDENSATE PIPING THROUGH
WALL TO SPILL TO GRADE.
4 1/2"CW TO TRAP PRIMER. REFER TO
DETAIL C1/P-501.
CB
CC
A1
A2
A3
A4
A5
A6
A7
A8
A2.5
A3.5
A4.5
A5.5
A6.5
A7.5
B1
B2
B4
B5
B3
A
/ P P
A
/ P P
A4 / PP112
A2 / PP113
A
B
C
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
P R
O F
E S
S
IO
N A
L E
N G
IN
E
E R
IN
G
C O
N S
U L T
A N
T S
P
.A
S
T O
P E
K A
W
IC
H
IT
A K
S
C P
R Z
Y G
O D
A
PP111
O V
E R
A L L S
E C
O N
D F
L O
O R
P L U
M B
IN
G
P L A
N
J O
IN
T
B A
S E
L E
W
IS
-M C
C H
O R
D W
A
S E
A T
T L E
D
IS
T R
IC
T
E
M
A R
G
IN
A L W
A Y
S O
U T
H B
L D
G
S E
A T
T L E
W
A
-2
D E
W
IN
G
M N
E W
M A
N
C W
A P
E L H
O R
S T
A
U G
U S
T
T B
D
T B
D
RTA DESIGN SUBMITTAL
R E
P A
IR
B
U
IL
D
IN
G
D E
S
IG
N C
O N
S T
R U
C T
IO
N
P K
G N
O C
E C
E
1/16" = 1'-0"A4
OVERALL SECOND FLOOR PLUMBING PLAN
PLAN NORTH
0 8' 16' 32'
C
C1 C2 C3 C4
C3.5C2.5
A1
A2
A2.5
B1
B2
B4
B5
B3
NEC COMM
STAIR C
C2
STOR
UTILITY
256C
FIRE RISER
256D
NEC COMM
CLOSET253
CLOSET
X
JAN
256A
ELEC
STAIR B
B2
ELEC / COMMERCIAL TELECOMM
P-402 D1
P-402 D5
P-402 D1
P-402 D1
P-402 D1
P-402 D1
P-402 D1
P-402 D5
P6.1
P6.1
A
/ P P
A2 / PP113
P-403 D1
SIMILAR
SIMILAR
SIMILAR
SIMILAR
P4.13/4"H&CW, 3"W AND 2"V
FROM 3RD FLOOR AND
DOWN TO 1ST FLOOR.
1/2"CW, 1 1/2"V AND 2"W
FROM 3RD FLOOR AND
DOWN TO 1ST FLOOR.
MSS-201
CO3/4"3/4"CD
3/4"CD DOWN FACE
OF WALL TO SPILL
TO P4.1 VIA AIR GAP.
CO
MSS-202
MSS-203
CO
CO
UTILITY
UNIT
UNIT
UNIT
UNIT
UNIT
2"V UP TO 3RD FLOOR AND
DOWN TO 1ST FLOOR.
1 1/2"HWC UP TO 3RD FLOOR
AND DOWN TO 1ST FLOOR.
SIMILAR
1 1/2"V UP TO 3RD FLOOR
AND DOWN TO 1ST FLOOR.
2 1/2"V UP TO 3RD FLOOR
AND DOWN TO 1ST FLOOR.
2"FD ON 2ND FLOOR AND
2"W UP TO 3RD FLOOR FD.
2"W FROM 3RD FLOOR AND
DOWN TO 1ST FLOOR.
3/4"CD FROM FCU-224
DOWN TO FIRST FLOOR.
1/2"CW, 1 1/2"V AND 2"W
FROM 3RD FLOOR AND
DOWN TO 1ST FLOOR.
1 1/2"1 1/2"V
4"CO
2"FD
PLUMBING GENERAL NOTES
1. REFERENCE PLUMBING FIXTURE
SCHEDULE ON SHEET P-601 FOR PIPING
RUN OUT AND CONNECTION SIZES.
2. FOR ALL NEW PENETRATIONS IN PRECAST
HOLLOW CORE SLABS, THE EXISTING
REINFORCING MUST BE LOCATED BY NON-
DESTRUCTIVE TESTING METHODS PRIOR
TO ANY CUTTING OR CORE DRILLING.
REFER TO DETAIL F4/S-501 FOR
APPROVED OPENING LOCATIONS.
3. ALL FLOOR DRAINS LOCATED IN
BATHROOMS SHALL HAVE TRAP GUARDS
INSTALLED PER DETAIL F1/P-501.
4. CONTRACTOR TO REMOVE SLAB AS
REQUIRED TO INSTALL BELOW GRADE
PIPING. REFERENCE ARCHITECTURAL
DRAWINGS AND STRUCTURAL DRAWINGS
SB112 AND SB113 AND DETAILS A4/S-501
AND A4/S-502 FOR PATCHING OR
REPLACEMENT OF EXISTING SLAB ON
GRADE.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
P R
O F
E S
S
IO
N A
L E
N G
IN
E
E R
IN
G
C O
N S
U L T
A N
T S
P
.A
S
T O
P E
K A
W
IC
H
IT
A K
S
C P
R Z
Y G
O D
A
PP112
S E
C O
N D
F L O
O R
A R
E A
B P
L U
M B
IN
G
P L A
N
J O
IN
T
B A
S E
L E
W
IS
-M C
C H
O R
D W
A
S E
A T
T L E
D
IS
T R
IC
T
E
M
A R
G
IN
A L W
A Y
S O
U T
H B
L D
G
S E
A T
T L E
W
A
-2
D E
W
IN
G
M N
E W
M A
N
C W
A P
E L H
O R
S T
A
U G
U S
T
T B
D
T B
D
RTA DESIGN SUBMITTAL
R E
P A
IR
B
U
IL
D
IN
G
D E
S
IG
N C
O N
S T
R U
C T
IO
N
P K
G N
O C
E C
E
PLAN NORTH
0 4' 8' 16'
SCALE: 1/8" = 1'1/8" = 1'-0"A4
PLUMBING PLAN - SECOND FLOOR AREA-B
PLAN NOTES
1 3/4"CD ROUTED TO FLOOR DRAIN
LOCATED IN MECHANICAL CLOSET.
TERMINATE CONDENSATE PIPING
ABOVE FLOOR DRAIN VIA AIR GAP.
2 1/2"CW TO TRAP PRIMER. REFER TO
DETAIL C1/P-501.
3 3/4"CD ROUTED TO FLOOR DRAIN
LOCATED IN UTILITY RM 201. TERMINATE
CONDENSATE PIPING ABOVE FLOOR
DRAIN VIA AIR GAP.
4 EXISTING BUILDING SEISMIC JOINT,
REFERENCE STRUCTURAL. PROVIDE
FLEXIBLE JOINTS IN HVAC, PLUMBING
AND PIPING SYSTEMS PER
C
A3
A4
A5
A6
A7
A8
A2.5
A3.5
A4.5
A5.5
A6.5
A7.5
STAIR A
A2
JAN
UTILITY
P-402 D1
P-402 D1
P-402 D1
P-402 D1
P-402 D1
P-402 D5
P-402 D1
2"FD
P4.1
A4 / PP112
SIMILAR
SIMILAR
SIMILAR
REFER TO DETAIL D7/P-901
FOR ADDITIONAL PIPE SIZES.
(SIMILAR)
FCU-201 2
2"W FROM FLOOR DRAIN
ON 3RD FLOOR.
2"W DOWN AND 1-1/2"V UP
TRAP PRIMER LOCATED IN
MECHANICAL CLOSET. INSTALL
IN CW LINE SERVING SINK.
C4 C5 C6 C7 C8
C4.5 C5.5 C6.5 C7.5
CB
CC
P-402 D1
UTILITY
JAN
STAIR D
D2
P-402 D5
P-402 D1
P-402 D1
P-402 D1
2"FD
P4.1
A
/ P P
SIMILAR
SIMILAR
REFER TO DETAIL D7/P-901
FOR ADDITIONAL PIPE SIZES.
(SIMILAR)
FCU-223
2"W FROM FLOOR
DRAIN ON 3RD FLOOR.
2"W DOWN AND
1-1/2"V UP.
1-1/2"V UP
TRAP PRIMER LOCATED IN
MECHANICAL CLOSET. INSTALL
IN CW LINE SERVING SINK.
PLUMBING GENERAL NOTES
1. REFERENCE PLUMBING FIXTURE
SCHEDULE ON SHEET P-601 FOR PIPING
RUN OUT AND CONNECTION SIZES.
2. FOR ALL NEW PENETRATIONS IN PRECAST
HOLLOW CORE SLABS, THE EXISTING
REINFORCING MUST BE LOCATED BY NON-
DESTRUCTIVE TESTING METHODS PRIOR
TO ANY CUTTING OR CORE DRILLING.
REFER TO DETAIL F4/S-501 FOR
APPROVED OPENING LOCATIONS.
3. ALL FLOOR DRAINS LOCATED IN
BATHROOMS SHALL HAVE TRAP GUARDS
INSTALLED PER DETAIL F1/P-501.
4. CONTRACTOR TO REMOVE SLAB AS
REQUIRED TO INSTALL BELOW GRADE
PIPING. REFERENCE ARCHITECTURAL
DRAWINGS AND STRUCTURAL DRAWINGS
SB112 AND SB113 AND DETAILS A4/S-501
AND A4/S-502 FOR PATCHING OR
REPLACEMENT OF EXISTING SLAB ON
GRADE.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
P R
O F
E S
S
IO
N A
L E
N G
IN
E
E R
IN
G
C O
N S
U L T
A N
T S
P
.A
S
T O
P E
K A
W
IC
H
IT
A K
S
C P
R Z
Y G
O D
A
PP113
S E
C O
N D
F L O
O R
A R
E A
A A
N D
C P
L U
M B
IN
G
P L A
N
J O
IN
T
B A
S E
L E
W
IS
-M C
C H
O R
D W
A
S E
A T
T L E
D
IS
T R
IC
T
E
M
A R
G
IN
A L W
A Y
S O
U T
H B
L D
G
S E
A T
T L E
W
A
-2
D E
W
IN
G
M N
E W
M A
N
C W
A P
E L H
O R
S T
A
U G
U S
T
T B
D
T B
D
RTA DESIGN SUBMITTAL
R E
P A
IR
B
U
IL
D
IN
G
D E
S
IG
N C
O N
S T
R U
C T
IO
N
P K
G N
O C
E C
E
PLAN NORTH
0 4' 8' 16'
SCALE: 1/8" = 1'
1/8" = 1'-0"A2
PLUMBING PLAN - SECOND FLOOR AREA-A
1/8" = 1'-0"A6
PLUMBING PLAN - SECOND FLOOR AREA-C
PLAN NOTES
1 1/2"CW TO TRAP PRIMER. REFER TO
DETAIL C1/P-501.
2 3/4"CD FROM FAN COIL UNIT ON THIRD
FLOOR. 3/4"CD ROUTED TO MOP SINK.
TERMINATE CONDENSATE PIPING
ABOVE MOP SINK VIA AIR GAP. ROUTE
3/4"CD FROM FCU ON SECOND FLOOR
DOWN TO FIRST FLOOR MOP BASIN.
CB
CC
A1
A2
A3
A4
A5
A6
A7
A8
A2.5
A3.5
A4.5
A5.5
A6.5
A7.5
B1
B2
B4
B5
B3
P1.1 P3.1
P5.1
P2.1 P7.1 P8.1
A
/ P P
A
/ P P
A4 / PP122
A2 / PP123
A
B
C
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
P R
O F
E S
S
IO
N A
L E
N G
IN
E
E R
IN
G
C O
N S
U L T
A N
T S
P
.A
S
T O
P E
K A
W
IC
H
IT
A K
S
C P
R Z
Y G
O D
A
PP121
O V
E R
A L L T
H
IR
D F
L O
O R
P L U
M B
IN
G
P L A
N
J O
IN
T
B A
S E
L E
W
IS
-M C
C H
O R
D W
A
S E
A T
T L E
D
IS
T R
IC
T
E
M
A R
G
IN
A L W
A Y
S O
U T
H B
L D
G
S E
A T
T L E
W
A
-2
D E
W
IN
G
M N
E W
M A
N
C W
A P
E L H
O R
S T
A
U G
U S
T
T B
D
T B
D
RTA DESIGN SUBMITTAL
R E
P A
IR
B
U
IL
D
IN
G
D E
S
IG
N C
O N
S T
R U
C T
IO
N
P K
G N
O C
E C
E
1/16" = 1'-0"A4
OVERALL THIRD FLOOR PLUMBING PLAN
PLAN NORTH
0 8' 16' 32'
C
C1 C2 C3 C4
C3.5C2.5
A1
A2
A2.5
B1
B2
B4
B5
B3
NEC COMM
STAIR C
C3
ELEC
UTILITY
356C
FIRE RISER
356D
NEC COMM
JAN
356A
ELEC
STAIR B
B3
ELEC / COMMERCIAL TELECOMM
P-402 A1
P-402 A1
P-402 A5
P-402 A1
P-402 A1
P-402 A1
P-402 A5
P-402 A1
P6.1
P6.1
P-403 D4
A
/ P P
A2 / PP123
SIMILAR
SIMILAR
SIMILAR
SIMILAR
P4.1
2"V UP AND 3"W, 3/4"CW &
3/4"HW DOWN TO 2ND FLOOR.
1/2"1/2"HWCMSS-301
CO
CO3/4"3/4"CD
3/4"CD DOWN FACE
OF WALL TO SPILL
TO P4.1 VIA AIR GAP.
CO
CO
MSS-303
MSS-302
SIMILAR
1"1"HWC
1 1/2"1 1/2"HWC
1"1"HWC
1"1"HWC 1"1"HWC
1/2"CW, 1-1/2"V AND 2"W
DOWN TO 2ND FLOOR.
1-1/2"V UP TO ATTIC.
2 1/2"V UP TO ATTIC AND
DOWN TO 2ND FLOOR.
1 1/2"V UP TO ATTIC AND
DOWN TO 2ND FLOOR.
1/2"CW, 1-1/2"V AND 2"W
DOWN TO 2ND FLOOR.
1-1/2"V UP TO ATTIC.
2"FD
2"V UP TO ATTIC AND
2"W DOWN TO 2ND FLOOR.
2"V UP TO ATTIC AND
DOWN TO 2ND FLOOR.
(TYP.)
(TYP.)
(TYP.)
LADDER
PLUMBING GENERAL NOTES
1. REFERENCE PLUMBING FIXTURE
SCHEDULE ON SHEET P-601 FOR PIPING
RUN OUT AND CONNECTION SIZES.
2. FOR ALL NEW PENETRATIONS IN PRECAST
HOLLOW CORE SLABS, THE EXISTING
REINFORCING MUST BE LOCATED BY NON-
DESTRUCTIVE TESTING METHODS PRIOR
TO ANY CUTTING OR CORE DRILLING.
REFER TO DETAIL F4/S-501 FOR
APPROVED OPENING LOCATIONS.
3. ALL FLOOR DRAINS LOCATED IN
BATHROOMS SHALL HAVE TRAP GUARDS
INSTALLED PER DETAIL F1/P-501.
4. CONTRACTOR TO REMOVE SLAB AS
REQUIRED TO INSTALL BELOW GRADE
PIPING. REFERENCE ARCHITECTURAL
DRAWINGS AND STRUCTURAL DRAWINGS
SB112 AND SB113 AND DETAILS A4/S-501
AND A4/S-502 FOR PATCHING OR
REPLACEMENT OF EXISTING SLAB ON
GRADE.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
P R
O F
E S
S
IO
N A
L E
N G
IN
E
E R
IN
G
C O
N S
U L T
A N
T S
P
.A
S
T O
P E
K A
W
IC
H
IT
A K
S
C P
R Z
Y G
O D
A
PP122
T H
IR
D
F L O
O R
A R
E A
B P
L U
M B
IN
G
P L A
N
J O
IN
T
B A
S E
L E
W
IS
-M C
C H
O R
D W
A
S E
A T
T L E
D
IS
T R
IC
T
E
M
A R
G
IN
A L W
A Y
S O
U T
H B
L D
G
S E
A T
T L E
W
A
-2
D E
W
IN
G
M N
E W
M A
N
C W
A P
E L H
O R
S T
A
U G
U S
T
T B
D
T B
D
RTA DESIGN SUBMITTAL
R E
P A
IR
B
U
IL
D
IN
G
D E
S
IG
N C
O N
S T
R U
C T
IO
N
P K
G N
O C
E C
E
PLAN NORTH
0 4' 8' 16'
SCALE: 1/8" = 1'1/8" = 1'-0"A4
PLUMBING PLAN - THIRD FLOOR AREA-B
PLAN NOTES
1 DOMESTIC HOT WATER RECIRCULATION
PIPING DOWN TO FIRST FLOOR
MECHANICAL ROOM.
2 3/4"CD ROUTED TO FLOOR DRAIN
LOCATED IN MECHANICAL CLOSET.
TERMINATE CONDENSATE PIPING
ABOVE FLOOR DRAIN VIA AIR GAP.
3 PROVIDE CHECK VALVE AND
CALIBRATED BALANCE VALVE AT EACH
1/2" RUNOUT. SET EACH VALVE TO
0.25GPM. (TYP)
4 1/2"CW TO TRAP PRIMER. REFER TO
DETAIL C1/P-501.
5 EXISTING BUILDING SEISMIC JOINT,
REFERENCE STRUCTURAL. PROVIDE
FLEXIBLE JOINTS IN HVAC, PLUMBING
AND PIPING SYSTEMS PER
C
A3
A4
A5
A6
A7
A8
A2.5
A3.5
A4.5
A5.5
A6.5
A7.5
MECH
STAIR A
A3
JAN
P-402 A1
P-402 A1
P-402 A1
P-402 A1
P-402 A1
P-402 A1
P-402 A5
2"FD
P4.1
A4 / PP122
SIMILAR
SIMILAR
SIMILAR
1"1"HWC
REFER TO DETAIL
D7/P-901 FOR ADDITIONAL
PIPE SIZES.
3/4"3/4"HWC
3/4"3/4"HWC
1"1"HWC
CHECK VALVE AND
CALIBRATED BALANCE
VALVE. SET VALVE TO 3 GPM.
1 1/2"1 1/2"CD
1 1/2"V UP
TO ATTIC
2"FD
DOAS-1
ROUTE TRAP
PRIMER LINE FROM
KITCHEN SINK
FCU-301
MAINTAIN MANUFACTURER'S
RECOMMENDED SERVICE
CLEARANCE (TYPICAL).
C4 C5 C6 C7 C8
C4.5 C5.5 C6.5 C7.5
CB
CC
MECH
JAN
STAIR D
D3
P-402 A5P-402
A1
P-402 A1
P-402 A1
P-402 A1
P4.1
2"FD
A
/ P P
SIMILAR
SIMILAR
3/4"3/4"HWC
REFER TO DETAIL D7/P-901
FOR ADDITIONAL PIPE
SIZES (SIMILAR).
1"1"HWC
3/4"3/4"HWC
CHECK VALVE AND
CALIBRATED BALANCE
VALVE. SET VALVE TO 2 GPM.
2"FD
DOAS-2
1 1/4"1 1/4"CD
ROUTE TRAP
PRIMER LINE FROM
KITCHEN SINK
1 1/2"1 1/2"V
2"V UP
TO ATTIC
FCU-323
MAINTAIN MANUFACTURER'S
RECOMMENDED SERVICE
CLEARANCE (TYPICAL).
PLUMBING GENERAL NOTES
1. REFERENCE PLUMBING FIXTURE
SCHEDULE ON SHEET P-601 FOR PIPING
RUN OUT AND CONNECTION SIZES.
2. FOR ALL NEW PENETRATIONS IN PRECAST
HOLLOW CORE SLABS, THE EXISTING
REINFORCING MUST BE LOCATED BY NON-
DESTRUCTIVE TESTING METHODS PRIOR
TO ANY CUTTING OR CORE DRILLING.
REFER TO DETAIL F4/S-501 FOR
APPROVED OPENING LOCATIONS.
3. ALL FLOOR DRAINS LOCATED IN
BATHROOMS SHALL HAVE TRAP GUARDS
INSTALLED PER DETAIL F1/P-501.
4. CONTRACTOR TO REMOVE SLAB AS
REQUIRED TO INSTALL BELOW GRADE
PIPING. REFERENCE ARCHITECTURAL
DRAWINGS AND STRUCTURAL DRAWINGS
SB112 AND SB113 AND DETAILS A4/S-501
AND A4/S-502 FOR PATCHING OR
REPLACEMENT OF EXISTING SLAB ON
GRADE.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
P R
O F
E S
S
IO
N A
L E
N G
IN
E
E R
IN
G
C O
N S
U L T
A N
T S
P
.A
S
T O
P E
K A
W
IC
H
IT
A K
S
C P
R Z
Y G
O D
A
PP123
T H
IR
D
F L O
O R
A R
E A
A A
N D
C P
L U
M B
IN
G
P L A
N
J O
IN
T
B A
S E
L E
W
IS
-M C
C H
O R
D W
A
S E
A T
T L E
D
IS
T R
IC
T
E
M
A R
G
IN
A L W
A Y
S O
U T
H B
L D
G
S E
A T
T L E
W
A
-2
D E
W
IN
G
M N
E W
M A
N
C W
A P
E L H
O R
S T
A
U G
U S
T
T B
D
T B
D
RTA DESIGN SUBMITTAL
R E
P A
IR
B
U
IL
D
IN
G
D E
S
IG
N C
O N
S T
R U
C T
IO
N
P K
G N
O C
E C
E
PLAN NORTH
0 4' 8' 16'
SCALE: 1/8" = 1'
1/8" = 1'-0"A2
PLUMBING PLAN - THIRD FLOOR AREA-A
1/8" = 1'-0"A6
PLUMBING PLAN - THIRD FLOOR AREA-C
PLAN NOTES
1 PROVIDE CHECK VALVE AND
CALIBRATED BALANCE VALVE AT EACH
1/2" RUNOUT. SET EACH VALVE TO
0.25GPM. (TYP)
2 3/4"CD ROUTED TO MOP SINK ON FLOOR
BELOW. TERMINATE CONDENSATE
PIPING ABOVE MOP SINK VIA AIR GAP.
3 3/4"CD ROUTED TO FLOOR DRAIN.
TERMINATE CONDENSATE PIPING
ABOVE FLOOR DRAIN VIA AIR GAP.
C7 C8
CB
UNIT
P1.1
P3.1
P2.1
P7.1
P8.1
P5.1
2"FD
1"HW UP TO
2ND FLR.
2"FD
2"CW AND 1-1/4"HW
TO MAINS IN CORR.
2"CW AND 1-1/4"HW
UP TO 2ND FLOOR.
1 1/2"1 1/2"CW
1 1/4"1 1/4"HW
1"1"HW
1 1/2"1 1/2"CW
3/4"3/4"HW
3/4"3/4"CW
4"CO
WHA-B
1/2"CW ABOVE FLOOR
TO SERVE DRAIN ABOVE.
2"W FROM FD ABOVE
C4 C5
P8.1
P2.1
P7.1
P1.1
P3.1
1/2"1/2"CW
3/4"3/4"HW
3/4"3/4"CW
3/4"3/4"CW
SHUT-OFF VALVE (TYP)
1"CW&HW 2"CW &UP TO
2ND FLOOR.
2"CW & 1"HW
FROM MAINS.
1 1/4"CW & 1"HW
UP TO 2ND FLOOR.
P5.1
2"FD
UNIT
2"FD
112"W ABOVE CEILING
2"W FROM FD ABOVE
WHA-A
WHA-B
1/2"CW DOWN TO
BELOW GRADE TO
SERVE 1ST FLOOR
FLOOR DRAIN.
1/2"CW ABOVE FLOOR TO
SERVE FLOOR DRAIN ABOVE.
1"1"HW
1"HW UP TO
2ND FLOOR.
3/4"3/4"CW
C7 C8
CB
UNIT
4"4" W
4"CO
4"4" W
2"2"W
2"2"W
2"W FROM
FLOOR DRAIN
2"W FROM
FLOOR DRAIN
P5.1
P1.1
P3.1
P2.1
P7.1
C4 C5
UNIT
2"2"W
2"W FROM
FLOOR DRAIN.
2"W FROM
FLOOR DRAIN.
2"CO
2"2" W
2"2"W 4"4"W 3"3"W2"2"W
P3.1
P5.1
P1.1P7.1
P2.1
PLUMBING GENERAL NOTES
1. REFERENCE PLUMBING FIXTURE
SCHEDULE ON SHEET P-601 FOR PIPING
RUN OUT AND CONNECTION SIZES.
2. FOR ALL NEW PENETRATIONS IN PRECAST
HOLLOW CORE SLABS, THE EXISTING
REINFORCING MUST BE LOCATED BY NON-
DESTRUCTIVE TESTING METHODS PRIOR
TO ANY CUTTING OR CORE DRILLING.
REFER TO DETAIL F4/S-501 FOR
APPROVED OPENING LOCATIONS.
3. ALL FLOOR DRAINS LOCATED IN
BATHROOMS SHALL HAVE TRAP GUARDS
INSTALLED PER DETAIL F1/P-501.
4. CONTRACTOR TO REMOVE SLAB AS
REQUIRED TO INSTALL BELOW GRADE
PIPING. REFERENCE ARCHITECTURAL
DRAWINGS AND STRUCTURAL DRAWINGS
SB112 AND SB113 AND DETAILS A4/S-501
AND A4/S-502 FOR PATCHING OR
REPLACEMENT OF EXISTING SLAB ON
GRADE.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
P R
O F
E S
S
IO
N A
L E
N G
IN
E
E R
IN
G
C O
N S
U L T
A N
T S
P
.A
S
T O
P E
K A
W
IC
H
IT
A K
S
C P
R Z
Y G
O D
A
P-401
E N
L A
R G
E D
P L U
M B
IN
G
P L A
N S
J O
IN
T
B A
S E
L E
W
IS
-M C
C H
O R
D W
A
S E
A T
T L E
D
IS
T R
IC
T
E
M
A R
G
IN
A L W
A Y
S O
U T
H B
L D
G
S E
A T
T L E
W
A
-2
D E
W
IN
G
M N
E W
M A
N
C W
A P
E L H
O R
S T
A
U G
U S
T
T B
D
T B
D
RTA DESIGN SUBMITTAL
R E
P A
IR
B
U
IL
D
IN
G
D E
S
IG
N C
O N
S T
R U
C T
IO
N
P K
G N
O C
E C
E
1/4" = 1'-0"A5
UNIT - 1RM ENLARGED FIRST FLOOR PLAN
1/4" = 1'-0"A1
UNIT - 2RM ENLARGED FIRST FLOOR PLAN
PLAN NOTES
1 WASTE AND VENT RISERS. REFER TO
PLUMBING ISOMETRICS FOR
ADDITIONAL PIPE SIZES.
2 3/4"CD ROUTED TO FLOOR DRAIN
LOCATED IN MECHANICAL CLOSET.
TERMINATE CONDENSATE PIPING
ABOVE FLOOR DRAIN VIA AIR GAP.
3 1/2"CW TO TRAP PRIMER. REFER TO
DETAIL C1/P-501.
1/4" = 1'-0"E5
UNIT - 1RM ENLARGED BELOW GRADE PLAN
1/4" = 1'-0"D1
UNIT - 2RM ENLARGED BELOW GRADE PLAN
PLAN NORTH
0 2' 4' 8'
SCALE: 1/4" = 1'
C4 C5
P3.1
P1.1
2"FD2"FD
P7.1
P2.1
P8.1
P5.1
1/2"1/2"HWC
3/4"3/4"CW
1 1/4"1 1/4"CW
3/4"3/4"HW
3/4"3/4"CW
1"CW&HW DOWN 1 1/2"CW DOWN
1/2"1/2"HWC
WHA-A
WHA-B
3/4"3/4"HW
3/4"3/4"CW
3/4"DOWN TO 2ND FLOOR
C7 C8
CB
P5.1
2"FD
P1.1
P3.1
2"FD
P7.1
P2.1
P8.1
3/4"3/4"HW
3/4"3/4"CW1 1/2"1 1/2"CW
1/2"1/2"HW
2"CW AND
1"HW DOWN
1 1/2"1 1/2"CW
1/2"1/2"HWC
1/2"1/2"HW
WHA-B
1/2"1/2"HWC
1/2"1/2"HWC
3/4"HW DOWN TO
2ND FLOOR.
C4 C5
P8.1
P2.1
P1.1 P5.1
P7.1
SHUT-OFF VALVE (TYP)1"CW&HW 1 1/2"CW UP
TO 3RD FLOOR.
1"CW & 1"HW
UP TO 3RD FLOOR.
3/4"3/4"CW
P3.1
2"FD
2"FD
2"W ABOVE CEILING
WHA-A
WHA-B
2"W FROM FD ABOVE
1/2"CW FROM TRAP PRIMER
CONNECTED TO FLOOR
DRAIN ON 3RD FLOOR.
1 1/2"1 1/2"CW
3/4"3/4"HW
3/4"3/4"CW
3/4"3/4"HW
3/4"3/4"CW
1"HW DOWN TO 1ST FLOOR
AND 3/4"HW UP TO 3RD FLOOR.
C7 C8
CB
P8.1
2"FD
2"FD
3/4"3/4"HW
3/4"3/4"CW
1 1/2"1 1/2"CW
1/2"1/2"HW
1"1"HW
WHA-B
2"CW AND 1"HW UP
TO THIRD FLOOR
2"W FROM FD ABOVE
P1.1
P3.1
P5.1
P2.1
P7.1
1 1/2"1 1/2"CW
1"HW DOWN TO 2ND FLOOR
AND 3/4"HW UP TO 3RD FLOOR.
PLUMBING GENERAL NOTES
1. REFERENCE PLUMBING FIXTURE
SCHEDULE ON SHEET P-601 FOR PIPING
RUN OUT AND CONNECTION SIZES.
2. FOR ALL NEW PENETRATIONS IN PRECAST
HOLLOW CORE SLABS, THE EXISTING
REINFORCING MUST BE LOCATED BY NON-
DESTRUCTIVE TESTING METHODS PRIOR
TO ANY CUTTING OR CORE DRILLING.
REFER TO DETAIL F4/S-501 FOR
APPROVED OPENING LOCATIONS.
3. ALL FLOOR DRAINS LOCATED IN
BATHROOMS SHALL HAVE TRAP GUARDS
INSTALLED PER DETAIL F1/P-501.
4. CONTRACTOR TO REMOVE SLAB AS
REQUIRED TO INSTALL BELOW GRADE
PIPING. REFERENCE ARCHITECTURAL
DRAWINGS AND STRUCTURAL DRAWINGS
SB112 AND SB113 AND DETAILS A4/S-501
AND A4/S-502 FOR PATCHING OR
REPLACEMENT OF EXISTING SLAB ON
GRADE.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
P R
O F
E S
S
IO
N A
L E
N G
IN
E
E R
IN
G
C O
N S
U L T
A N
T S
P
.A
S
T O
P E
K A
W
IC
H
IT
A K
S
C P
R Z
Y G
O D
A
P-402
E N
L A
R G
E D
P L U
M B
IN
G
P L A
N S
J O
IN
T
B A
S E
L E
W
IS
-M C
C H
O R
D W
A
S E
A T
T L E
D
IS
T R
IC
T
E
M
A R
G
IN
A L W
A Y
S O
U T
H B
L D
G
S E
A T
T L E
W
A
-2
D E
W
IN
G
M N
E W
M A
N
C W
A P
E L H
O R
S T
A
U G
U S
T
T B
D
T B
D
RTA DESIGN SUBMITTAL
R E
P A
IR
B
U
IL
D
IN
G
D E
S
IG
N C
O N
S T
R U
C T
IO
N
P K
G N
O C
E C
E
1/4" = 1'-0"A1
UNIT - 2RM ENLARGED THIRD FLOOR PLAN
1/4" = 1'-0"A5
UNIT - 1RM ENLARGED THIRD FLOOR PLAN
PLAN NOTES
1 WASTE AND VENT RISERS. REFER TO
PLUMBING ISOMETRICS FOR
ADDITIONAL PIPE SIZES.
2 3/4"CD ROUTED TO FLOOR DRAIN
LOCATED IN MECHANICAL CLOSET.
TERMINATE CONDENSATE PIPING
ABOVE FLOOR DRAIN VIA AIR GAP.
3 1/2"CW TO TRAP PRIMER. REFER TO
DETAIL C1/P-501.
1/4" = 1'-0"D1
UNIT - 2RM ENLARGED SECOND FLOOR PLAN
1/4" = 1'-0"D5
UNIT - 1RM ENLARGED SECOND FLOOR PLAN
PLAN NORTH
0 4' 8' 16'
SCALE: 1/8" = 1'
B3
P2.1
P8.1
P7.1
P1.1
2"FD
P3.1
1 1/2"1 1/2"CW
3/4"3/4"CW
3/4"3/4"CW
3/4"3/4"HW
1/2"1/2"HWC
3/4"3/4"HW
1/2"1/2"CW
P5.1
WHA-B
UNIT
STORAGE
INSTALL ISLAND VENT
PER DETAIL A8/P-501.
1"HW DOWN
TO 2ND FLOOR.
1 1/2"CW DOWN
TO 2ND FLR.
1"1"HW
SHUT OFF VALVE (TYP)
FCU-312
1-1/2"V UP ATTIC
2"FD
B3
P2.1
P1.1
2"FD
P3.1
P8.1
P7.1
WHA-B
SHUT OFF VALVE (TYP)
1 1/2"1 1/2"CW
1 1/4"1 1/4"HW
3/4"3/4"CW
3/4"3/4"CW
3/4"3/4"HW
1/2"1/2"CW
P5.1
INSTALL ISLAND VENT
PER DETAIL A8/P-501.
UNIT
UTILITY
201 2"W FROM
FD ABOVE.
2"CW AND 1 1/4"HW DOWN
TO 1ST FLOOR. 1 1/2"CW
UP TO 3RD FLOOR.
1"HW UP TO
3RD FLOOR.
1"1"HW
2"W FROM 3RD
FLOOR SINK, P2.1.
FCU-212
PLUMBING GENERAL NOTES
1. REFERENCE PLUMBING FIXTURE
SCHEDULE ON SHEET P-601 FOR PIPING
RUN OUT AND CONNECTION SIZES.
2. FOR ALL NEW PENETRATIONS IN PRECAST
HOLLOW CORE SLABS, THE EXISTING
REINFORCING MUST BE LOCATED BY NON-
DESTRUCTIVE TESTING METHODS PRIOR
TO ANY CUTTING OR CORE DRILLING.
REFER TO DETAIL F4/S-501 FOR
APPROVED OPENING LOCATIONS.
3. ALL FLOOR DRAINS LOCATED IN
BATHROOMS SHALL HAVE TRAP GUARDS
INSTALLED PER DETAIL F1/P-501.
4. CONTRACTOR TO REMOVE SLAB AS
REQUIRED TO INSTALL BELOW GRADE
PIPING. REFERENCE ARCHITECTURAL
DRAWINGS AND STRUCTURAL DRAWINGS
SB112 AND SB113 AND DETAILS A4/S-501
AND A4/S-502 FOR PATCHING OR
REPLACEMENT OF EXISTING SLAB ON
GRADE.
B2
MUDROOM
152 3"CO
3"CO
P7.1P7.1
P2.2 (TYP.6)
1 1/4"HW & CW2"FD2"FD
2"2" V
1 1/2"1 1/2"V
2"2"V2 1/2"V, SEE SHEET
PP102 FOR CONT.
3"W TO MAIN
1"HW & CW
3"3" W
2"2"V
2"2"V1 1/2"V
2"W
3"3"W
3"WCO
SHUT OFF
VALVES (TYP)
1"1"HW
1"1"CW
3/4"3/4"HW
3/4"3/4"CW
C1 C2B5
MECH
(2 PSI)1"1"G1"1"G
1 1/4"1 1/4"G(2 PSI)
1 1/2"1 1/2"G(2 PSI)
B-2
B-1
WH-1 WH-2
WHP-2
WHP-1
ST-1
AGP-2
DHWP-1
2"V. SEE SHEET PP102
FOR CONTINUATION.
1/
2"
1/ 2"
V
2"2"V
1/
2"
1/ 2"
V
1 1/2"1 1/2"V
1 1/2"1 1/2"HWC
3"3"HW
3"3"CW
2"CW AND 1-1/4"HW
UP TO 2ND FLOOR.
SHUT-OFF
VALVE (TYP)
3"CW&HW TO
COORIDOR.
1 1/4"1 1/4"G
1"1"G1"1"G(2 PSI)
(2 PSI)
1 1/4"1 1/4"CW
3/4"3/4"CW
1 1/4"1 1/4"CW
4"W UP TO
CLEANOUT P9.1
1"1"HW
1"HW UP TO
2ND FLOOR.
ET-3
3/4"3/4"HW
3"3"HW
2"2"CW2"2"CW
1 1/4"1 1/4"G1 1/4"1 1/4"G
1 1/2"1 1/2"G
1 1/2"1 1/2"G 1616
3"3"HW
3"3"HW
2"CW DOWN
TO TANK.
MAINTAIN MANUFACTURER'S
RECOMMENDED SERVICE
CLEARANCE (TYPICAL).
C1 C2B5
MECH
2"W UP
4"W UP
6"6" W
6"6" W
2"2"W
4"4"W
2"2"W
2"FD
AGP-2
B-2
B-1
WH-1 WH-2
2"FD
ST-1
2"FD
1 1/2"V UP
1 1/2"V UP
6"6"W
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
P R
O F
E S
S
IO
N A
L E
N G
IN
E
E R
IN
G
C O
N S
U L T
A N
T S
P
.A
S
T O
P E
K A
W
IC
H
IT
A K
S
C P
R Z
Y G
O D
A
P-403
E N
L A
R G
E D
P L U
M B
IN
G
P L A
N S
A
R E
A B
J O
IN
T
B A
S E
L E
W
IS
-M C
C H
O R
D W
A
S E
A T
T L E
D
IS
T R
IC
T
E
M
A R
G
IN
A L W
A Y
S O
U T
H B
L D
G
S E
A T
T L E
W
A
-2
D E
W
IN
G
M N
E W
M A
N
C W
A P
E L H
O R
S T
A
U G
U S
T
T B
D
T B
D
RTA DESIGN SUBMITTAL
R E
P A
IR
B
U
IL
D
IN
G
D E
S
IG
N C
O N
S T
R U
C T
IO
N
P K
G N
O C
E C
E
1/4" = 1'-0"D4
UNIT - 2RM ENLARGED THIRD FLOOR AREA-B
1/4" = 1'-0"D1
UNIT - 2RM ALT ENLARGED SECOND FLOOR AREA-B
PLAN NOTES
1 WASTE AND VENT RISERS. REFER TO PLUMBING ISOMETRICS
FOR ADDITIONAL PIPE SIZES.
2 PROVIDE CHECK VALVE AND CALIBRATED BALANCE VALVE AT
EACH 1/2" RUNOUT. SET EACH VALVE TO 0.25GPM. (TYP)
3 3/4"CD ROUTED TO FLOOR DRAIN LOCATED IN MECHANICAL
CLOSET. TERMINATE CONDENSATE PIPING ABOVE FLOOR
DRAIN VIA AIR GAP.
4 1/2"CW TO TRAP PRIMER. REFER TO DETAIL C1/P-501.
5 ROUTE HW/CW/V PIPING BACK OF CABINET WALL "STACKED"
BELOW COUNTERTOP TO SINK. (PIPE SPACING IS SHOWN FOR
CLARITY)
6 3/4"CD ROUTED TO FLOOR DRAIN LOCATED IN UTILITY RM 201.
TERMINATE CONDENSATE PIPING ABOVE FLOOR DRAIN VIA AIR
GAP.
7 FLOOR DRAINS IN MECHANICAL ROOM 107 AND UTILITY 104A
SHALL HAVE TRAP GUARD INSERT INSTALLED PER DETAIL
F1/P-501.
8 TOTAL ESTIMATED NATURAL GAS LOAD: 2,088. CFH
REQUESTED GAS PRESSURE DOWNSTREAM OF UTILITY
METER: 2PSI. PROVIDE GAS METER WITH PULSE OUTPUT TO
REPORT USAGE DATA TO THE JBLM METERING VLAN. METER
SHALL BE COMPATIBLE WITH BASEWIDE UTILITY MONITORING
SYSTEM SEE TEMPERATURE CONTROLS DRAWING M-705 FOR
ADDITIONAL REQUIREMENTS.
9 4"W FROM WATER CLOSETS - P1.1
10 2"W FROM LAVATORIES - P3.1
11 2"W FROM FLOOR DRAINS
12 2"W FROM SHOWERS - P5.1
13 2"W FROM SINK - P2.1
14 2"W FROM WASHER BOXES - P7.1
15 INSTALL TMV-1 PER MANUFACTURER'S RECOMMENDATIONS.
SEE DETAIL D5/P-502 FOR ADDITIONAL REQUIREMENTS.
16 INSTALL STEP-DOWN REGULATOR AT EQUIPMENT
CONNECTION. 2 PSI INCOMING PRESSURE, OUTLET PRESSURE
TO BE VERIFIED WITH EQUIPMENT MANUFACTURER PRIOR TO
ORDERING.
17 EXISTING BUILDING SEISMIC JOINT, REFERENCE STRUCTURAL.
PROVIDE FLEXIBLE JOINTS IN HVAC, PLUMBING AND PIPING
SYSTEMS PER SPECIFICATIONS SECTION 13 48 00.00 10.
PLAN NORTH
0 2' 4' 8'
SCALE: 1/4" = 1'
1/4" = 1'-0"A7
PLUMBING PLAN - FIRST FLOOR AREA-B - MUDROOM
1/4" = 1'-0"A4
ABOVE GRADE PLUMBING PLAN - MECH 107
1/4" = 1'-0"A1
BELOW GRADE PLUMBING PLAN - MECH 107
ADJUST TO FINISH
GRADE
HEAVY DUTY CLEANOUT WITH
CAST IRON TOP
4" PIPE UP TO
GRADE
FLOWFLOW
24"x24"x6" CONCRETE
COLLAR OR PAVEMENT
TWO PIECE THREADED
ADJUSTABLE HOUSING
THREADED BRONZE OR PVC
TAPERED PLUG
COMBINATION WYE AND 1/8
BEND OR LONG SWEEP ELL
SEWER LINE
B A
UNIT TYPE
DRAW THRU
BLOW THRU
A B
2" PLUS X X+1"
1" MIN. 2X
WHERE X = STATIC PRESSURE IN PAN
DRAIN PAN
DRAIN LINE SHALL BE AT LEAST THE
SAME SIZE AS THE NIPPLE ON THE
DRAIN PAN (3/4" MINIMUM).
OPEN VENT
PITCH DOWN TOWARD DRAIN
CLEANOUT
OPEN
DRAIN
1"
PVC COMBUSTION PIPING (TYPICAL)
CPVC OR STAINLESS STEEL
FLUE EXHAUST PIPING PER
MANUFACTURER'S
RECOMMENDATIONS ON FLUE
MATERIAL TYPE (TYPICAL)
FULL SIZE DOMESTIC HOT
WATER RETURN MANIFOLD
HOT WATER RETURN FROM STORAGE TANK
HOT WATER SUPPLY TO STORAGE TANK
FLEXIBLE CONN. (TYP.)
WATER HEATER WH-1
4" THICK CONCRETE EQUIPMENT
PAD. EXTEND PAD MINIMUM 4"
BEYOND PERIMETER OF EQUIPMENT.
FULL SIZE DOMESTIC HOT
WATER SUPPLY MANIFOLD
THERMOMETER (TYP.)
SHUT-OFF VALVES (TYP.)
WHP-1
WHP-2
DIRT LEG (TYP.)
UNION (TYP.)
WATER HEATER MANUFACTURER'S CONDENSING DRAIN KIT
WITH TRAP, PIPE TO FLOOR DRAIN FUNNEL, TYPICAL. PROVIDE
CONDENSATE NEUTRALIZATION KIT. DRAIN KIT WITH TRAP
(TYP.). ROUTE TO NEAREST FLOOR DRAIN.
GAS COCK, TYPICAL
GAS PIPING TO EACH
WATER HEATER, TYPICAL
RELIEF VALVE. PIPE DISCHARGE
TO FLOOR DRAIN (TYP.)
MAINTAIN MAINTENANCE CLEARANCE
PER WATER HEATER MANUFACTURER'S
REQUIREMENTS (TYP.)
WATER HEATER WH-2
BALL VALVE, TYPICAL
PRESSURE GAUGE, TYPICAL
RETURN TO WATER HEATER, TYPICAL
NOTE: PROVIDE PRESSURE AND
TEMPERATURE RELIEF PER WATER HEATER
MANUFACTURER'S INSTRUCTIONS. PIPE FULL
SIZE TO FLOOR DRAIN FUNNEL.
PRESSURE REGULATING VALVE
SUPPLY FROM WATER HEATER, TYPICAL
REFER TO SPECIFICATIONS FOR
BELOW-GRADE PIPING, FITTING, AND
JOINT MATERIALS AND REQUIREMENTS.
1" COLD WATER PIPING.
36" MINIMUM
IN HYDRANT OFF
POSITION.
FINISHED GRADE
OR PAVING.
BRASS BACKFLOW
PREVENTER WITH 3/4"
MALE HOSE THREAD
OUTLET.
LEVER OPERATOR
LINK.
GALVANIZED STEEL
PIPE CASING.
INSTALL ADAPTER/
BUSHING ABOVE
GRADE FOR SERVICE
ACCESS.
PISTON ASSEMBLY.
CYLINDER ASSEMBLY.
ANCHOR HYDRANT BELOW
GRADE PER MANUFACTURER'S
INSTRUCTIONS.
2" VENT. SEE PLAN FOR
CONTINUATION.
45` ELL
90` ELL
2" VENT PIPE
FLOOR
SEE PLAN FOR
CONTINUATION.
NOTE: INSTALL PER LOCAL
PLUMBING CODE REQUIREMENTS.
2"X 1 1/2" SANITARY "T"
2" SANITARY "T"
W/ C.O. PLUG
1 1/2" DEEP SEAL
"P" TRAP W/ C.O. PLUG
SINK DRAIN FITTING
COLD WATER
DISTRIBUTION LINE -
1-1/2" OR SMALLER
TAP OFF TOP OF LINE
1/2" BALL
VALVE
ADJUSTABLE TRAP PRIMER WITH
INTEGRAL VACUUM BREAKER. SIZE PER
FLOOR DRAIN QUANTITY.
WHERE TRAP PRIMER NOT INSTALLED IN
ACCESSIBLE SPACE, PROVIDE MIN. 12"x12" SS
ACCESS DOOR
NOTE: AVOID IMBEDDING CW LINE TO
TRAP IN CONCRETE IF LINE MUST BE
IMBEDDED IN SLAB, INSULATE WITH
MIN. 3/8" THICK ARMAFLEX INSULATION.
FLOOR
WHERE TUBING PENETRATES SLAB,
INSULATE WITH MIN. 3/8" THICK
ARMAFLEX INSULATION.
NO JOINTS IN OR BELOW SLAB
DEEP SEAL "P" TRAP W/ TRAP
PRIMER CONNECTION.
PREFERRED METHOD.
PITCH
DN
1/2"CW
PITCH
DN
1/2"CW
WHERE MULTIPLE DRAINS PRIMED,
PROVIDE DISTRIBUTION UNIT BY
PRIMER MFR.
FLOOR DRAIN WITH TRAP
PRIMER CONNECTION.
ALTERNATE METHOD.
"M
IN
NOTE: TRAP PRIMER REQUIRED ON ALL
FLOOR DRAINS EXCEPT FOR FLOOR
DRAINS SERVING PRIVATE RESTROOMS
UNLESS NOTED OTHERWISE.
FLOOR/HUB DRAIN
FLOOR
CLOSED
DIAPHRAGM
WATER PIPE
OPEN DIAPHRAGM
WASTE PIPE
NOTES:
1. FLOOR DRAINS LOCATED IN MECHANICAL ROOM 107,
UTILITY 104A AND PRIVATE RESTROOMS SHALL HAVE
TRAP GUARDS.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
P R
O F
E S
S
IO
N A
L E
N G
IN
E
E R
IN
G
C O
N S
U L T
A N
T S
P
.A
S
T O
P E
K A
W
IC
H
IT
A K
S
C P
R Z
Y G
O D
A
P-501
P L U
M B
IN
G
D E
T A
IL
S
J O
IN
T
B A
S E
L E
W
IS
-M C
C H
O R
D W
A
S E
A T
T L E
D
IS
T R
IC
T
E
M
A R
G
IN
A L W
A Y
S O
U T
H B
L D
G
S E
A T
T L E
W
A
-2
D E
W
IN
G
M N
E W
M A
N
C W
A P
E L H
O R
S T
A
U G
U S
T
T B
D
T B
D
RTA DESIGN SUBMITTAL
R E
P A
IR
B
U
IL
D
IN
G
D E
S
IG
N C
O N
S T
R U
C T
IO
N
P K
G N
O C
E C
E
NO SCALEA1
CLEANOUT DETAIL - TWO-WAY EXTERIOR
NO SCALEA4
AIR HANDLING UNIT DRAIN TRAP
NO SCALED4
WATER HEATER DETAIL - MODULAR CONDENSING
NO SCALED8
YARD HYDRANT DETAIL - SANITARY
NO SCALEA8
ISLAND VENT DETAIL
NO SCALEC1
TRAP PRIMER DETAIL
NO SCALEF1
TRAP GUARD DETAIL
P
P R
O X
. 3 6"
A .F
.F
CLEANOUT, TYP.
2" P-TRAP, TYP.
1ST FLOOR
2" DRAIN CONNECTION, TYP.
2" WASTE
3/4" HOT AND COLD WATER
BRANCH…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .