This is a Structural Condition Assessment document for a residential property located at 25 W Harrison Avenue in Babylon, New York, prepared for the U.S. Army Corps of Engineers' Fire Island Inlet to Montauk Point (FIMP) Nonstructural Pilot Project. The assessment, conducted on 03/10/2025, provides a comprehensive evaluation of the property's structural integrity, including detailed measurements of the 905 square foot home built in 1947, with a two-story wood-frame construction situated in Flood Zone AE. The assessment rates the structure's general condition as "Excellent", noting minor issues such as small wall cracks and non-uniform wood supports in the crawlspace, with key special considerations including the need to lift the rear deck and utility vent stack during potential elevation work.

The structural analysis includes extensive documentation of the building's components, including floor systems (2x6 wood platform framing), foundation type (CMU walls with wood framing), roof system (2x6 rafters at 16" spacing), and utility configurations. Specific observations include a steel beam in the living room, supplemental wood posts in the crawlspace, and multiple load-bearing walls. The property's lowest floor elevation is 5.55 feet, with the Base Flood Elevation at 5' and Design Flood Elevation at 8'6", indicating potential flood mitigation requirements as part of the broader FIMP Nonstructural Pilot Project targeting residential structure elevations in Long Island, New York.

View the file

Other files

File Type Posted
6 Rosewood Rd Mastic Beach.pdf PDF
518 Riviera Dr Mastic Beach.pdf PDF
Solicitation Amendment W912DS26RA0070002 SF 30.pdf PDF
Solicitation Amendment W912DS26RA0070001 SF 30.pdf PDF
Part 6.03 - 6 Rosewood Rd, Mastic Beach.pdf PDF
Part 6.03 - 38 Montauk Dr, Mastic Beach.pdf PDF
Part 6.03 - 71 Laurelton Dr, Mastic Beach.pdf PDF
Part 6.03 - 70 S Bay Dr, Babylon.pdf PDF
Part 6.03 - 99 Bayview Dr, Mastic Beach.pdf PDF
Part 6.03 - 58 Huguenot Dr, Mastic Beach.pdf PDF
Part 6.03 - 61 Laurelton Dr, Mastic Beach.pdf PDF
Part 6.03 - 702 Riviera Dr, Mastic Beach.pdf PDF
Part 6.03 - 88 Huntington Dr, Mastic Beach.pdf PDF
Part 6.03 - 98 Bayview Dr, Mastic Beach.pdf PDF
Part 6.03 - 518 Riviera Dr, Mastic Beach.pdf PDF
Part 6.03 - 84 S Bay Dr, Babylon.pdf PDF
Part 6.03 - 450 Riviera Dr, Mastic Beach.pdf PDF
Part 6.03 - 23 W Harrison Ave, Babylon.pdf PDF
Part 6.03 - 15 Sheridan Rd, Babylon.pdf PDF
Part 6.03 - 17 Bayport Rd, Mastic Beach.pdf PDF
Part 6.03 - 100 Huntington Dr, Mastic Beach.pdf PDF
Part 6.03 - 105 Bayview Dr, Mastic Beach.pdf PDF
Part 6.03 - 100 Hickory Rd, Mastic Beach.pdf PDF
Part 2 - General Requirements.pdf PDF
Final DB RFP Table of Contents.pdf PDF
Part 6 Table of Contents.pdf PDF
Part 3 - Project Program.pdf PDF
Part 6.03 - 22 Blue Point Rd, Mastic Beach.pdf PDF
Part 6.03 - 2 Babylon Rd, Mastic Beach.pdf PDF
Part 6.03 - 8 Bluepoint Rd, Mastic Beach.pdf PDF
Part 6.03 - 20 Bayside Rd, Mastic Beach.pdf PDF
Part 6.03 - 681 Riviera Dr, Mastic Beach.pdf PDF
Part 6.03 - 86 Laurelton Dr, Mastic Beach.pdf PDF
Part 6.03 - 7 Gooseberry Rd, Mastic Beach.pdf PDF
Part 6.08 - Performance Assessment Plan Form [M].pdf PDF
Part 6.09 - Performance Rating Method Compliance Form [M].pdf PDF
Part 6.03 - 486 Riviera Dr, Mastic Beach.pdf PDF
Part 6.03 - 46 Montauk Dr, Mastic Beach.pdf PDF
Part 6.03 - 25 Pershing Ave, Babylon.pdf PDF
Part 6.03 - 22 Mitchell Ave, Babylon.pdf PDF
Part 6.03 - 29 Milton Rd, Babylon.pdf PDF
Part 6.03 - 21 W Harrison Ave, Babylon.pdf PDF
Part 6.03 - 24 Blue Point Rd, Mastic Beach.pdf PDF
Part 6.03 - 37 Cranberry Dr, Mastic Beach.pdf PDF
Part 6.03 - 10 Poplar Rd (Bldg 2), Mastic Beach.pdf PDF
Part 6.03 - 15 Milton Rd, Babylon.pdf PDF
Part 6.03 - 24 Babylon Rd, Mastic Beach.pdf PDF
Part 6.03 - 94 Bayview, Mastic Beach.pdf PDF
Solicitation - W912DS26RA007 Final.pdf PDF
Evaluation Factors R2.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Structural Condi�on Assessment Checklist

FIMP Pilot Project – Babylon and Brookhaven

USACE TRACKING #: 2790 ASSESSMENT DATE: 03/10/2025

1. Exterior finish materials (check all that apply. NP indicates Not Present):

☒ siding ☒ masonry ☐ masonry veneer* ☐ stone ☐ stone veneer

☐ �mber/wood ☐ wood shake ☒ concrete ☐ other

Typical shake/siding exposure:

*Note: where veneer is supported

2. Building access points (check all that apply):

Stairs Material(s) & Step Qty

☒ front ☒ Brick & Stone, 5 Steps

☐ side (left) ☐

☐ side (right) ☐

☒ back ☒ Wood Deck, 5 Steps

☐ interior (attached garage) ☐

☐ interior (basement) ☐

☐ basement bulkhead ☐

☒ crawlspace access ☐

☐ other ☐

3. Addi1on/a3achment number and size (check all that apply):

Quan�ty Area

☒ porch/pa�o (uncovered) 1 South – 38 SF

☐ porch/pa�o (covered)

☐ porch/pa�o (enclosed)

☒ deck (w/steps to grade) 1 North – 460 SF

☐ deck (w/out steps to grade)

☐ chimney (interior)

☒ chimney (exterior)

North – 6.25

SF

☐ garage (integral)

☐ garage (a1ached, adjacent)

☐ garage (a1ached, breezeway)

ADDRESS: 25 W Harrison COUNTY: Suffolk

CITY/TOWN: Babylon ZIP CODE: 11702

HOMEOWNER NAMES:

POC EMAIL: POC PHONE:

BASE FLOOD ELEVATION (BFE): 5’ – 0” DESIGN FLOOD ELEVATION (DFE): 8’ – 6”

ZONE: AE YEAR CONSTRUCTED: 1947

TOTAL AREA OF BUILDING FOOTPRINT (SF): 905 SF MAXIMUM BUILDING HEIGHT ALLOWED: 30 <

PROPERTY INFORMATION

GENERAL INFORMATION

USACE TRACKING #2790

☒ addi�on (interior access)

South - 167.75

SF

☐ addi�on (exterior access only)

☐ other

4. Accessible features (check all that apply) (NP):

☐ ramp ☐ chair li9 ☐ hydraulic li9 ☐ elevator ☐ other

5. Exterior improvements in work area (check all that apply):

☒ driveway ☒ pa�o/pavers ☐ retaining wall ☐ sidewalk ☒ landscaping

☐ pool/hot tub ☒ fence/gate ☒ other, Deck

6. Home Type

☐ Cape Cod ☐ Ranch ☐ Split Level ☐ Bungalow ☐ Cra9sman

☐ Co1age ☐ Farmhouse ☒ other, Bi Level

1. Approximate eleva1ons:

Top of founda�on +/- 3’ – 0” from crawlspace floor

Floor of basement / crawlspace +/- 1’ – 0” below grade

Lowest Struct Member Measured up from founda�on +/- 3’ – 0” from crawlspace floor

Floor of main living level +/- 3’ – 6” from crawlspace floor

Floor of lowest living level +/- 3’ – 6” from crawlspace floor

Floor of second floor +/- 11’ – 0” from grade

Other Not applicable

2. Floor system:

2.a. Main floor

Framing Size & Spacing 2x6 2 16” O.C.

Framing Type Wood plaKorm

Framing Direc�on See plan

2.b. Second floor

Framing Size & Spacing 2X6 wood (assumed)

(1) Steel beam in living room

(header)

Framing Type Wood plaKorm

Framing Direc�on See plan

3. Founda1on type (check all that apply):

Material

☐ basement (subgrade)

☐ basement (walkout)

☒ crawlspace CMU walls and wood framing

☐ slab on grade

☒ piers CMU supports

☐ piles

☒ posts/columns Wood posts

☐ other

STRUCTURAL SYSTEMS

4. Wall system (check all that apply):

Material

☒ frame (plaDorm) 2x6 (assumed)

☐ frame (balloon)

☐ masonry/stone (solid)

☐ monolithic/poured

☐ panel/manufactured

☐ other

5. Roof system (click all that apply):

Material

☒ frame 2x6 @ 16” ra9ers

2x6 @ 16” floor span

2x4 @ 12” wall

☐ truss

☐ panel

☐ other

6. Signs of building damage or poten1al structural issue (check all that apply):

☐ founda�on se1lement

☒ cracking ☐ dry rot ☐ termites ☐ other

☐ water damage/mold/sagging ☐ further inves�ga�on

7. Load bearing par11ons/posts (if applicable):

- Mul1ple load bearing walls throughout the building structure. See plan for loca1ons.

- (2) headers, one present in the kitchen and the other in living room space. See plan for loca1ons and photos S6-7 for reference.

8. Lateral resis1ng systems observed (if applicable):

Standard wood framing system.

9. Chimney connec1ons to structure (if applicable):

U1lity vent stack on the rear. The vent stack is completely surrounded by the rear deck. See plan for loca1on and photo S11 or reference.

10. Structural support for a3ached porches, decks, etc. (if applicable):

2x10 @ 16” framed deck in the rear. No visible structural connec1on from the deck to the building structure. See plan for loca1on and photo S12-13 for reference.

Front concrete entryway has no visible structural connec1on to the building structure. See plan for loca1on and photo S14 for reference.

11. Evidence of other upgrades or updates to the original structure?

Addi1on on the front of the original building structure. See plan for loca1on.

Supplemental wood posts and joists in the crawlspace. See plan for loca1on and photos S16-17 for reference.

1. Energy sources (check all that apply):

☐ oil ☒ natural gas ☒ electric ☐ propane ☐ wood burning

☒ solar

☐ other

1.a. Fuel storage tanks (NP)

Size/Quan�ty/Loca�on Below 1st Floor

☐ Oil, above-ground ☐

☐ Oil, underground ☐

☐ tank fill & vent lines ☐

☐ LP, above ground ☐

1.b. Fuel system components (NP)

Loca�on Below 1st Floor

☐ LP regulator or NG meter/regulator ☐

☐ LP/NG service valve ☐

☐ Fuel oil or LP or NG service piping ☐

2. Interior u1li1es (check all that apply)

Below 1st Floor Level

2.a. HVAC Equipment

☐ furnace (oil) ☐

☐ furnace (gas) ☐

☒ air handling unit ☐

☒ ductwork ☐

☐ baseboard heaters (elec) ☐

☐ boiler (oil) ☐

☒ boiler (gas) ☐

☒ baseboard heaters (hot water) ☐

☐ radiators (steam) ☐

☐ radiators (hot water) ☐

☐ radiators (electric) ☐

☐ hea�ng water piping ☐

☒ refrigerant piping ☐

☐ heat pump indoor unit ☐

☒ air condi�oning unit ☐

☐ wood stove ☐

☒ exhaust/flue rou�ng ☐

2b. Plumbing Equipment

☐ DHW heater (gas) ☐

☐ DHW heater (elec) ☐

☐ sump pump ☐

☒ sink ☐

☒ toilet ☐

☒ tub/shower ☐

☒ washer discharge ☐

☐ floor drain ☐

UTILITY

☐ pressure tank (well) ☐

☐ water filtra�on system ☐

☐ water service piping ☐

☐ drain (sewer) piping ☐

2c. Electrical Equipment

☒ elec. panel ☐

☒ elec. switches ☐

☒ elec. outlets ☐

☐ solar ba1ery ☐

☐ other ☐

3. Exterior u1li1es (check all that apply):

Below 1st Floor Level

3a. HVAC Equipment

☐ A/C compressor ☐

☐ heat pump outdoor unit ☐

☐ packaged unit ☐

☒ exhaust/flue rou�ng ☐

3b. Plumbing Equipment

☐ water meter ☐

☒ water service valve/box ☐

☐ water tank ☐

☐ water well/pump ☐

☐ sep�c tank ☐

☐ sep�c control panel ☐

☐ sep�c blower ☐

☒ irriga�on control panel ☐

3c. Electrical Equipment

☒ elec. meter ☐

☒ phone/cable junc�on box ☐

☐ satellite dish/TV antenna ☐

☐ generator ☐

☒ solar panel(s) ☐

☐ solar ba1ery ☐

☐ electric vehicle charging sta�on ☐

☒ fire, CO, or heat detector ☐

☒ quan�ty of fire/CO/heat detectors ☐

4. Are there connec1ng u1li1es to/from outbuildings or other structures? (NP)

Not observed.

5. Storm drainage (check all that apply): (NP)

Below 1st Floor Level

☐ downspouts, surface drain ☐

☐ downspouts, subsurface drain ☐

6. Water service:

Meter loca�on Lawn of house

Service entry loca�on

7. Sewer service: (NP)

☐ Town Sewer ☐

☐ Sep�c ☐

Service discharge loca�on

8. Electrical power service:

9. Phone service:

☐ not applicable ☐ underground ☐ overhead

Building entry point East of house

10. TV/fiber op1c service:

☒ not applicable ☐ underground ☐ overhead

☐ satellite dish/antenna Building entry point

11. Photos:

Exterior Eleva�ons: ☒ Front ☒ Right ☒ Back ☒ Le9

Structural: ☒ Columns ☒ Beams ☒ Joist Framing ☒ Founda�on

☒ AMc Framing ☒ Deck Framing

Electrical: ☒ Meter ☒ Panel ☒ U�lity Pole

Mechanical: ☒ Furnace/Boiler ☒ Hot Water Heater ☐ Pumps ☒ Water Meter

☐ A/C Compressor

Heat Pump/Split System: ☒ Ext. Unit ☒ Int. Unit ☐ Propane/Oil Tank

☐ underground ☐ overhead ☐ solar (primary) ☐ solar (supplemental)

Meter loca�on East of house

Meter number

U�lity Pole Number

Elec. panel loca�on

Elec. panel size Main breaker size – 200A

Qty 1pole 15A breaker – 8

Qty 1pole 20A breaker – 13

Qty 2pole 15A breaker – 2

Qty 2pole 20A breaker – 1

Qty 2pole 30A breaker – 1

Qty 2pole 50A breaker – 1

Qty AFCI breaker -

Qty GCFI breaker -

Other breaker -

Sub-panel loca�on

Qty 1pole 15A breaker -

Qty 1pole 20A breaker -

Qty 2 pole breaker 30A breaker -

Qty AFCI breaker -

Qty GCFI breaker -

Solar and/or generator disconnect loca�on ☒n/a

12. Others: (NP)

Not applicable.

General Structural Condi�on Ra�ngs

EXCELLENT – Structure can be easily elevated or floodproofed (as applicable) without major altera"ons. No construc"on accessibility issues.

GREAT – Structure can be elevated or floodproofed (as applicable) without any major altera"ons. Minor construc"on accessibility issues.

GOOD – Structure can be elevated or floodproofed (as applicable) with some altera"ons. Moderate construc"on accessibility issues.

FAIR – Structure can be elevated or floodproofed (as applicable), but complex with many unknowns. Major construc"on accessibility issues.

POOR – Structure cannot be elevated or floodproofed (as applicable) without major altera"ons/repairs beyond the Government’s mandate.

GENERAL STRUCTURAL CONDITION:

☐Excellent ☐Great ☒Good ☐Fair ☐Poor

Are all exterior egress doors, windows, & garage doors (as applicable) fully operable & properly func�oning?

☒Yes ☐No

Are all interior doors fully operable & properly func�oning? ☒Yes ☐No

Are there any accessibility features present at any of the structure’s entrances? ☐Yes ☒No

Are there any indica�ons present/past termite infesta�on &/or termite damage? ☐Yes ☒No

Are there any surrounding features that may affect or be affected by eleva�ng or floodproofing (as applicable)?

☐None ☐Pool ☐Retaining Wall ☒Decks ☐Other:

PROFESSIONAL OPINION:

For residen�al buildings, is the exis�ng structure structurally sounds & capable of withstanding the stresses imposed by the eleva�ng process without substan�al improvements? ☒Yes ☐No ☐N/A

REVIEWED & APPROVED BY:

SIGNATURE:

PROFESSIONAL LICENSE NO. (WITH STATE INITIALS):

PROFESSIONAL DESIGN FIRM:

INSPECTION TEAM:

Edited/Reviewed by:

☒ Roger Newman

Jus1fica1on of General Structural Condi1on Assessment:

The structure’s framing is uniform throughout. There are no visible structural deficiencies in any members, except for minor cracks in some areas of the first floor ceiling and second floor walls. The founda1on contains supplemental wood posts and joists to support the first floor in nonuniform loca1ons. A rear deck, u1lity vent stack, rear shed, and surrounding property fence may interfere with liTing.

BUILDING ELEVATION/FLOODPROOFING SUMMARY

DATE:

Floor Eleva on Survey Sheet

USACE TRACKING #: 2790 SURVEY DATE: 03/04/2025

ADDRESS: 25 W Harrison Ave COUNTY: Suffolk

CITY/TOWN: Babylon ZIP CODE: 11702

LEGAL DESCRIPTION AND/OR TAX PARCEL #:

0100-231.00-02.00-039.000, 472089 231.-2-39

FOUNDATION TYPE: ☐Slab on Grade ☐Basement ☒Crawlspace ☐Elevated Without Enclosure on Post, Piles or Piers

☐Elevated With Enclosure on Post, Piles or Piers ☐Elevated With Enclosure Not on Post, Piles or Piers

FLOOD HAZARD ZONE(S): AE FEMA BASE FLOOD ELEVATION(S) (BFE): 5’ – 0” FEMA BFE + 2: 8’ – 6”

BENCHMARK UTILIZED: NAD83 BM. VERTICAL DATUM: NAVD 88

BLDG. ELEV. DATUM: NAVD 88 OTHER: N/A

All Finish Floor Eleva�ons (FFE) to be taken at each exterior door threshold on the bo�om floor.

All eleva�ons to be provided in U.S. customary units to the nearest tenth of a survey foot.

If an item does not apply to the building, enter “N/A” for not applicable.

Datum used for building eleva4ons must be the same as that used for the BFE. Conversion factor used? ☐YES ☒NO

Conversion/Comments:

N/A

All measurements to be provided in U.S. customary units to the nearest ½ survey foot.

All calculated areas to be provided in U.S. customary units to the nearest 10 square feet.

If an item does not apply to the building, enter “N/A” for not applicable.

Square footage of first floor (excl. carports & detached porches): 904.5 square feet

Square footage of aBached garage: N/A square feet

Square footage of aBached decks and porches: North – Rear 460.84

South – Front 37.43 square feet

Horizontal distance between the aBached garage & edge of road (i.e. driveway length): 39.66 feet

Horizontal distance between the front building line and nearest fence/property line: 20.01 feet

Horizontal distance between the right building line & nearest fence/property line: 4.98 feet

Horizontal distance between the leE building line & nearest fence/property line: 12.29 feet

Horizontal distance between the rear building line & nearest fence/property line: 35.18 feet

BUILDING USE: ☐Commercial ☐Industrial ☒Residen4al Other:

LATITUDE: 40.678407 LONGITUDE: -73.335912

Top of the lowest floor (FFE): 5.55 feet

BoBom of the lowest horizontal structural member: Not observed feet

ABached garage (top of slab): N/A feet

Lowest eleva4on of Machinery & Equipment (M&E) servicing the building

(describe the type(s) of M&E and loca4on(s) in the Observa4ons & Notes Area):

Not observed feet

Lowest Adjacent Grade (LAG) next to building: ☐Natural ☒Finished 2.34 feet

Highest Adjacent Grade (HAG) next to building: ☐Natural ☒Finished 2.65 feet

Finished LAG at lowest eleva4on of aBached deck or stairs, including structural support: 2.34 feet

Edge of road pavement eleva4on at the driveway/roadway centerline-centerline intersec4on: 1.90 feet

PROPERTY INFORMATION

ELEVATION SUMMARY

MEASUREMENT SUMMARY

ELEVATION PHOTOGRAPHS

FRONT

REAR

LEFT

RIGHT

ELEVATION PHOTOGRAPHS

R

O

OPENING

DW KITCHEN

DINING

ROOM

BOILER

SERVICE

UP

LIVING

ROOM

BATH

ROOM

+/- 22'-91 2" +/- 21'-3"

+/- 13'-3 12 "

+/- 9'-7"

+/- 7'-4 12 "

+/- 11'-8"+/- 4'-2"+/- 9'-6"

+/- 2'-0"+/- 8'-2"

+/- 19'-3"

7'-11" AFF

CEILING

7'-10 1/2" AFF

CEILING

12'-2" AFF

CEILING

HIGH POINT

7'-10 1/2" AFF

CEILING

LOW POINT

7'-10 1/2" AFF

CEILING

LOW POINT

HALL

BEDROOM

BEDROOM

BEDROOM

BATHROOM

A

TT

IC

AB

O

VE

+/- 16'-1" +/- 4'-10"

+/- 11'-5"+/- 10'-11"+/- 2'-41 2"

+/- 12'-0 12 " +/- 8'-10 12 "

+/- 13'-8" +/- 11'-5"

DN

1/ 4"

'-0

R W

FA- R

W

H

AR

R

IS

O

N A

VE

W

ES

T, B

AB

YL

O

N , N

Y, EX

IS

TI

N

G F

LO

O

R P

LA

N

S

ST

R U

C

TU

R E

ID

: 2

A-100

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

PL

O

T D

AT

E:

1 SCALE: 1/4" = 1'-0"

PROPOSED FIRST FLOOR PLAN

2 SCALE: 1/4" = 1'-0"

PROPOSED SECOND FLOOR PLAN

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SU

BM

IT

TE

D B

Y:

C H

EC

KE

D B

Y:

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

IS

SU

E D

AT

E:

SI

ZE

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E

SHEET ID

SC

AL

E:

U

SA

C E

N

AN

R

IV

ER

IN

E

JO

IN

T

PA

R

TN

ER

S

A

R

LI

N G

TO

N

B

LV

D

FA

IR

FA

X, V

A

N ew

Y or k D is tri ct

F

ED

ER

AL

P

LA

ZA

N

EW

Y

O R

K, N

Y

W

2D S2

3D

/0

3/

AN

SI

D

W

2D S2

4F

FI

R

E

IS

LA

N

D

IN

LE

T

TO

M

O N

TA

U

K

PO

IN

T

(F

IM

P) C

O

AS

TA

L

ST

O

R M

R

IS

K R

E-

EV

AL

U

AT

IO

N N

O N

ST

R

U C

TU

R

AL

P

IL

O

T

BA

BY

LO

N

B R

O O

KH

AV

EN

N

EW

Y

O R

K

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

PL

O

T D

AT

E:

N

J un

7,

- 6

:0 3p m

R

O

OPENING

DW KITCHEN

DINING

ROOM

BOILER

SERVICE

UP

LIVING

ROOM

BATH

ROOM

+/- 22'-91 2" +/- 21'-3"

+/- 13'-3 12 "

+/- 9'-7"

+/- 7'-4 12 "

+/- 11'-8"+/- 4'-2"+/- 9'-6"

+/- 2'-0"+/- 8'-2"

+/- 19'-3"

7'-11" AFF

CEILING

7'-10 1/2" AFF

CEILING

12'-2" AFF

CEILING

HIGH POINT

7'-10 1/2" AFF

CEILING

LOW POINT

7'-10 1/2" AFF

CEILING

LOW POINT

HALL

BEDROOM

BEDROOM

BEDROOM

BATHROOM

A

TT

IC

AB

O

VE

+/- 16'-1" +/- 4'-10"

+/- 11'-5"+/- 10'-11"+/- 2'-41 2"

+/- 12'-0 12 " +/- 8'-10 12 "

+/- 13'-8" +/- 11'-5"

DN

1/ 4"

'-0

R W

FA- R

W

H

AR

R

IS

O

N A

VE

W

ES

T, B

AB

YL

O

N , N

Y, EX

IS

TI

N

G F

LO

O

R P

LA

N

S

ST

R U

C

TU

R E

ID

: 2

S-100

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

PL

O

T D

AT

E:

1 SCALE: 1/4" = 1'-0"

PROPOSED FIRST FLOOR PLAN

2 SCALE: 1/4" = 1'-0"

PROPOSED SECOND FLOOR PLAN

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SU

BM

IT

TE

D B

Y:

C H

EC

KE

D B

Y:

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

IS

SU

E D

AT

E:

SI

ZE

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E

SHEET ID

SC

AL

E:

U

SA

C E

N

AN

R

IV

ER

IN

E

JO

IN

T

PA

R

TN

ER

S

A

R

LI

N G

TO

N

B

LV

D

FA

IR

FA

X, V

A

N ew

Y or k D is tri ct

F

ED

ER

AL

P

LA

ZA

N

EW

Y

O R

K, N

Y

W

2D S2

3D

/0

3/

AN

SI

D

W

2D S2

4F

FI

R

E

IS

LA

N

D

IN

LE

T

TO

M

O N

TA

U

K

PO

IN

T

(F

IM

P) C

O

AS

TA

L

ST

O

R M

R

IS

K R

E-

EV

AL

U

AT

IO

N N

O N

ST

R

U C

TU

R

AL

P

IL

O

T

BA

BY

LO

N

B R

O O

KH

AV

EN

N

EW

Y

O R

K

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

PL

O

T D

AT

E:

N

J un

7,

- 6

:0 3p m

USACE TRACKING #2790

rgnewman Snapshot rgnewman Rectangle rgnewman Line rgnewman Rectangle rgnewman Line rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Text Box

LOAD BEARING CMU KNEE WALL BELOW

rgnewman Rectangle rgnewman Text Box

LEGEND:

rgnewman Line rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Line rgnewman Rectangle rgnewman Line rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Line rgnewman Line rgnewman Line rgnewman Rectangle rgnewman Text Box T rgnewman Line rgnewman Ellipse rgnewman Rectangle rgnewman Line rgnewman Callout

UTILITY

VENT STACK

rgnewman Rectangle rgnewman Line rgnewman Text Box D rgnewman Line rgnewman Line rgnewman Text Box W rgnewman Rectangle rgnewman Line rgnewman Callout

REAR DECK FRAMING

2X10 @ 16" rgnewman Ellipse rgnewman Line rgnewman Rectangle rgnewman Rectangle rgnewman Line rgnewman Rectangle rgnewman Line rgnewman Text Box 2x6 @ 16" rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Callout

HOT WATER BASEBOARD HEATER

rgnewman Callout

SPLIT SYSTEM AC

rgnewman Rectangle rgnewman Rectangle rgnewman Callout

PHONE SERVICE

rgnewman Rectangle rgnewman Callout

ELECTRIC METER

rgnewman Callout

SOLAR PANEL DISCONNECT

rgnewman Rectangle rgnewman Callout

SPLIT SYSTEM CONDENSER

rgnewman Rectangle rgnewman Callout

GAS METER

rgnewman Line rgnewman Callout

HEAT PUMP CONDENSER

rgnewman Rectangle rgnewman Callout

SPLIT SYSTEM AC

rgnewman Line rgnewman Line rgnewman Callout

200A ELECTRIC PANEL

rgnewman Callout

NATURAL GAS BOILER

rgnewman Line rgnewman Callout

HOT WATER HEATER

rgnewman Text Box 2x6 @ 16" rgnewman Text Box T rgnewman Line rgnewman Ellipse rgnewman Line rgnewman Text Box

SD

rgnewman Line rgnewman Ellipse rgnewman Text Box 2x6 @ 16"

(ASSUMED)

rgnewman Line rgnewman Text Box

SD

rgnewman Ellipse rgnewman Rectangle rgnewman Line rgnewman Callout

FRONT ENTRYWAY

rgnewman Rectangle rgnewman Rectangle rgnewman Callout

EMERGENCY SHUTOFF

rgnewman Callout

NON-UNIFORM WOOD SUPPORTS

(TYP FOR 5)

rgnewman Callout

IRRIGATION CONTROL

rgnewman Callout

WOOD POST

rgnewman Callout

CMU SUPPORT

rgnewman Callout

CMU SUPPORT

rgnewman Callout

APPROX. LOCATION OF 2X6 GIRDER

rgnewman Callout

APPROX. LOCATION OF 2X8 GIRDER

rgnewman Rectangle rgnewman Rectangle rgnewman Callout

APPROX. LOCATION OF WOOD SUPPORTS

rgnewman Callout

APPROX. LOCATION OF 2X6 GIRDER

rgnewman Callout

APPROX. LOCATION OF 2X6 GIRDER

rgnewman Callout

APPROX. LOCATION OF 2X6 GIRDER

rgnewman Rectangle rgnewman Text Box

APPROX. AREA OF ADDITION

rgnewman Line rgnewman Line rgnewman Line rgnewman Text Box 2x6 (ASSUMED) rgnewman Line rgnewman Line rgnewman Line rgnewman Line rgnewman Line rgnewman Line rgnewman Text Box

WOOD JOIST SPAN DIRECTION

rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Text Box

LOAD BEARING/EXTERIOR WALL

rgnewman Text Box

LEGEND:

rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Line rgnewman Rectangle rgnewman Rectangle rgnewman Callout

HEADER

rgnewman Rectangle rgnewman Text Box

APPROX. AREA OF ADDITION

rgnewman Rectangle rgnewman Callout

STEEL BEAM INDICATED BY OWNER

rgnewman Line rgnewman Callout

ROOF PEAK

(TYP)

rgnewman Arrow rgnewman Arrow rgnewman Text Box

UP

rgnewman Text Box

UP

rgnewman Line rgnewman Line rgnewman Line rgnewman Text Box 2x6 (ASSUMED) rgnewman Line rgnewman Line rgnewman Line rgnewman Text Box 2x6 (ASSUMED) rgnewman Line rgnewman Line rgnewman Line rgnewman Text Box 2x6

(ASSUMED)

rgnewman Line rgnewman Arrow rgnewman Text Box

UP

rgnewman Arrow rgnewman Text Box

UP

rgnewman Rectangle rgnewman Text Box

APPROX. AREA OF SECOND FLOOR ABOVE

rgnewman Rectangle rgnewman Text Box

APPROX. AREA OF

INACCESSIBLE

ATTIC AREA

rgnewman Callout

2X6 RAFTERS (ASSUMED)

rgnewman Callout

2X6 RAFTERS (ASSUMED)

rgnewman Rectangle rgnewman Callout

UTILITY

VENT STACK

rgnewman Rectangle rgnewman Callout

GENERATOR STAND

2X6 @ 12"

4X4 INCLINED POSTS

rgnewman Line rgnewman Line rgnewman Line rgnewman Text Box

WOOD JOIST SPAN DIRECTION

rgnewman Rectangle rgnewman Text Box T rgnewman Text Box

RED TEXT = STRUCTURAL NOTES

BLUE TEXT = MEP NOTES

rgnewman Ellipse rgnewman Rectangle rgnewman Rectangle rgnewman Line rgnewman Rectangle rgnewman Line rgnewman Rectangle rgnewman Rectangle rgnewman Line rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Line rgnewman Line rgnewman Rectangle rgnewman Line rgnewman Rectangle rgnewman Line rgnewman Line rgnewman Line rgnewman Line rgnewman Line rgnewman Rectangle rgnewman Line rgnewman Text Box 2x6 @ 16" rgnewman Line rgnewman Line rgnewman Text Box 2x6 @ 16" rgnewman Rectangle rgnewman Callout

2X6 @ 16" RAFTERS

2X4 @ 12" WALL

(3) 2X6 COLLAR BEAMS

rgnewman Line rgnewman Arrow rgnewman Line rgnewman Arrow rgnewman Rectangle rgnewman Text Box

UP

rgnewman Text Box

UP

rgnewman Line rgnewman Line rgnewman Line rgnewman Callout

ROOF PEAK

rgnewman Callout

AIR HANDLING UNIT IN ATTIC

rgnewman Rectangle rgnewman Line rgnewman Rectangle rgnewman Rectangle rgnewman Line rgnewman Text Box

LOAD BEARING/EXTERIOR WALL

rgnewman Line rgnewman Text Box

LEGEND:

rgnewman Line rgnewman Line rgnewman Rectangle rgnewman Line rgnewman Line rgnewman Line rgnewman Rectangle rgnewman Text Box

WOOD JOIST SPAN DIRECTION

rgnewman Line rgnewman Rectangle

Special Considera�ons

1. Rear deck and u�lity vent stack to be li$ed.

2. Non-uniform supports in the crawlspace. Supplemental wood posts added to exis�ng supports.

3. Exis�ng access doors from the front yard and back yard; variance from the zoning ordinance is required for new stair and landing encroaching front and back yard setback a$er raising of the structure.

4. Exis�ng central air system uses R410A type refrigerant.

ADDRESS: 25 W Harrison Ave COUNTY: Suffolk

CITY/TOWN: Babylon ZIP CODE: 11702

PROPERTY INFORMATION

SPECIAL CONSIDERATIONS

Structural Condi�on Assessment Summary- Appendix

USACE TRACKING #: 2790 ASSESSMENT DATE: 03/03/2025

• Provide a descrip ve cap on with each photographic. Limit two photographs per page.

ID: #

ADDRESS: 25 Harrison Ave W, Babylon, NY 11702

DATE: 03/03/2025

DESCRIPTION: Exterior

Exterior photo of south façade facing

Harrison Ave W.

PHOTO: #A1

ID: #

ADDRESS: 25 Harrison Ave W, Babylon, NY 11702

DATE: 03/03/2025

DESCRIPTION:

Exterior photo of stairs in south facade and of the main entry of living room.

PHOTO: #A2

Assessment Photographs

Structural Condi�on Assessment Summary - Appendix

Babylon, NY 11702

DATE: 03/03/2025

DESCRIPTION: Exterior

Exterior photo of north façade - backyard with porch and steps.

PHOTO: #A3

ID: #

ADDRESS: 25 Harrison Ave W, Babylon, NY 11702

DATE: 03/03/2025

DESCRIPTION: Exterior

Exterior photo of east façade – side yard.

PHOTO: #A4

Babylon, NY 11702

DATE: 03/03/2025

DESCRIPTION: 1st Floor

Photo of typical living room with wooden flooring and painted walls.

PHOTO: #A5

ID: #

ADDRESS: 25 Harrison Ave W, Babylon, NY 11702

DATE: 03/03/2025

DESCRIPTION: 1st Floor

Photo of typical bathroom with ,led flooring.

PHOTO: #A6

Babylon, NY 11702

DATE: 03/03/2025

DESCRIPTION: 1st Floor

Photo of typical kitchen with ,led flooring.

PHOTO: #A7

ID: #

ADDRESS: 25 Harrison Ave W, Babylon, NY 11702

DATE: 03/03/2025

DESCRIPTION: 1st Floor

Photo of u,lity room with boiler and laundry equipment.

PHOTO: #A8

Babylon, NY 11702

DATE: 03/03/2025

DESCRIPTION: 2nd Floor

Photo of hallway on 2nd floor with carpet flooring.

PHOTO: #A9

ID: #

ADDRESS: 25 Harrison Ave W, Babylon, NY 11702

DATE: 03/03/2025

DESCRIPTION: 2nd Floor

Photo of typical bedroom on 2nd floor with carpet flooring.

PHOTO: #A10

Babylon, NY 11702

DATE: 03/10/2025

DESCRIPTION:

A�c space showing 2X6 @ 16” ra)ers, 2x6 collar beams, and 2x4 @ 12” wall studs. Viewing to the right of the building.

PHOTO: S#1

ID: #

ADDRESS: 25 Harrison Ave W, Babylon, NY 11702

DATE: 03/10/2025

DESCRIPTION:

A�c space showing ra)ers and collar beams. Viewing to the le) of the building.

PHOTO: S#2

Babylon, NY 11702

DATE: 03/10/2025

DESCRIPTION:

A�c space showing 2x6 @ 16” floor span and ra)ers.

PHOTO: S#3

ID: #

ADDRESS: 25 Harrison Ave W, Babylon, NY 11702

DATE: 03/10/2025

DESCRIPTION:

Wall crack seen bedroom bearing wall.

PHOTO: S#4

Babylon, NY 11702

DATE: 03/10/2025

DESCRIPTION:

Wall crack seen in bedroom par77on wall above doorway.

PHOTO: S#5

ID: #

ADDRESS: 25 Harrison Ave W, Babylon, NY 11702

DATE: 03/10/2025

DESCRIPTION:

Header between the kitchen and living room spaces.

PHOTO: S#6

Babylon, NY 11702

DATE: 03/10/2025

DESCRIPTION:

Header, with embedded steel beam inside, in the living room space.

Separa7on between original structure and front addi7on.

PHOTO: S#7

ID: #

ADDRESS: 25 Harrison Ave W, Babylon, NY 11702

DATE: 03/10/2025

DESCRIPTION:

Ceiling cracks seen below loca7on of steel girder in header.

PHOTO: S#8

Babylon, NY 11702

DATE: 03/10/2025

DESCRIPTION:

Elevated wood 2x6 @ 12” framing for generator.

PHOTO: S#9

ID: #

ADDRESS: 25 Harrison Ave W, Babylon, NY 11702

DATE: 03/10/2025

DESCRIPTION:

Exterior view of generator stand on the right side of the building.

PHOTO: S#10

Babylon, NY 11702

DATE: 03/10/2025

DESCRIPTION:

U7lity vent stack on the rear of the building and surrounded by rear decking.

PHOTO: S#11

ID: #

ADDRESS: 25 Harrison Ave W, Babylon, NY 11702

DATE: 03/10/2025

DESCRIPTION:

Deck as seen from the rear.

PHOTO: S#12

Babylon, NY 11702

DATE: 03/10/2025

DESCRIPTION:

Rear decking 2x10 @16” framing.

PHOTO: S#13

ID: #

ADDRESS: 25 Harrison Ave W, Babylon, NY 11702

DATE: 03/10/2025

DESCRIPTION:

Front concrete entryway.

PHOTO: S#14

Babylon, NY 11702

DATE: 03/10/2025

DESCRIPTION:

Crawlspace showing 2x6 @ 16” first floor framing, girders, and CMU supports.

PHOTO: S#15

ID: #

ADDRESS: 25 Harrison Ave W, Babylon, NY 11702

DATE: 03/10/2025

DESCRIPTION:

Crawlspace showing girder, first floor framing, and supplemental wood supports. An addi7onal 2X8 beam can be seen in the rear, as indicated by the red arrow.

PHOTO: S#16

Babylon, NY 11702

DATE: 03/10/2025

DESCRIPTION:

Crawlspace showing first floor framing, supplemental wood supports, and CMU founda7on wall.

PHOTO: S#17

ID: #

ADDRESS: 25 Harrison Ave W, Babylon, NY 11702

DATE: 03/10/2025

DESCRIPTION:

Natural gas water heater and boiler located in boiler room.

PHOTO: M#1

Babylon, NY 11702

DATE: 03/10/2025

DESCRIPTION:

Loca7on of the electric meter, split system condenser, air handing unit condenser and gas meter.

PHOTO: M#2

25 Harrison Ave- 040425
25 W Harrison Ave, Babylon plan
078127_25 W Harrison Ave_First Floor
078127_25 W Harrison Ave_First Floor-11x17
078127_25 W Harrison Ave_Second Floor
078127_25 W Harrison Ave_Second Floor-11x17
Floor Elevation Survey Sheet - Rev01
Structural Condition Assessment Checklist - Rev02
Structural Condition Assessment Special Considerations
Structural Condition Assessment Summary - Photographs