Part 6.03 - 64 Elder Dr, Mastic Beach.pdf
PDF 31 MB Posted
- Solicitation number
- W912DS26RA007
About this file
This document is a Structural Condition Assessment Checklist for a residential property located at 64 Elder Drive in Mastic Beach, New York, prepared as part of the Fire Island Inlet to Montauk Point (FIMP) Nonstructural Pilot Project by the U.S. Army Corps of Engineers. The comprehensive assessment, conducted on January 15, 2025, details the property's structural characteristics, including a concrete foundation with 8-inch thick walls, 2x8 main floor framing, and platform framing construction. The building, constructed in 1986, is situated in Flood Zone AE with a Base Flood Elevation of 6'-0" and a Design Flood Elevation of 9'-6".
The assessment rates the structure's general condition as "Excellent", indicating it can be easily elevated without major alterations. Key findings include two wood-framed decks attached to the building, a sump pump in the basement, minor facade cracks on the concrete foundation, and the presence of five metal posts along the building's centerline. The property features a basement with utilities including a boiler, 175-gallon fuel oil tank, 40-gallon electric water heater, and a 150A electric panel. The evaluation confirms the structure is structurally sound and capable of withstanding the elevation process, with recommendations to raise the decks and vent stack during potential flood mitigation efforts.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Structural Condi�on Assessment Checklist
FIMP Pilot Project – Babylon and Brookhaven
USACE TRACKING #: 9027 ASSESSMENT DATE: 1/15/2025
1. Exterior finish materials (check all that apply. NP indicates Not Present):
☒ siding ☐ masonry ☐ masonry veneer* ☐ stone ☐ stone veneer
☐ �mber/wood ☐ wood shake ☒ concrete ☐ other
Typical shake/siding exposure:
*Note: where veneer is supported
2. Building access points (check all that apply):
Stairs Material(s) & Step Qty
☐ front ☐
☒ side (left) ☒ Wood, 9 Steps
☒ side (right) ☒ Wood, 10 Steps
☐ back ☐
☐ interior (attached garage) ☐
☐ interior (basement) ☐
☐ basement bulkhead ☐
☐ crawlspace access ☐
☐ other ☐
3. Addi2on/a4achment number and size (check all that apply):
Quan�ty Area
☐ porch/pa�o (uncovered)
☐ porch/pa�o (covered)
☐ porch/pa�o (enclosed)
☒ deck (w/steps to grade)
North – 78.19 SF, South – 10.75 SF
☐ deck (w/out steps to grade)
☐ chimney (interior)
☒ chimney (exterior) 1 3 SF
☐ garage (integral)
☐ garage (a0ached, adjacent)
☐ garage (a0ached, breezeway)
☐ addi�on (interior access)
ADDRESS: 64 Elder Dr COUNTY: Suffolk
CITY/TOWN: Mas�c Beach ZIP CODE: 11951
HOMEOWNER NAMES:
POC EMAIL: POC PHONE:
BASE FLOOD ELEVATION (BFE): 6’-0” DESIGN FLOOD ELEVATION (DFE): 9’-6”
ZONE: AE YEAR CONSTRUCTED: 1986
TOTAL AREA OF BUILDING FOOTPRINT (SF): MAXIMUM BUILDING HEIGHT ALLOWED: 35 =
PROPERTY INFORMATION
GENERAL INFORMATION
USACE TRACKING #9027
☐ addi�on (interior access)
☐ addi�on (exterior access only)
☐ other
4. Accessible features (check all that apply): (NP)
☐ ramp ☐ chair li: ☐ hydraulic li: ☐ elevator ☐ other
5. Exterior improvements in work area (check all that apply):
☒ driveway ☐ pa�o/pavers ☒ retaining wall ☐ sidewalk ☒ landscaping
☐ pool/hot tub ☒ fence/gate ☒ other (Deck)
6. Home Type
☐ Cape Cod ☐ Ranch ☐ Split Level ☐ Bungalow ☐ Cra:sman
☐ Co0age ☐ Farmhouse ☒ other
1. Approximate eleva2ons:
Top of founda�on +/- 4’ – 0” above grade (varies)
Floor of basement / crawlspace +/- 2’-3’ below grade (varies)
Lowest Struct Member Measured up from founda�on Basement floor (slab on grade)
Floor of main living level
+/- 4’ – 0” above ground level
(varies depending on loca�on of grade around the founda�on)
Floor of lowest living level +/- 4’ – 0” above ground level
Floor of second floor Not applicable
Other Not applicable
2. Floor system:
2.a. Main floor
Framing Size & Spacing 2X8 @ 16” O.C.
Framing Type PlaHorm
Framing Direc�on See plan
2.b. Second floor Not applicable
Framing Size & Spacing Not applicable
Framing Type Not applicable
Framing Direc�on Not applicable
3. Founda2on type (check all that apply):
Material
☒ basement (subgrade) Concrete
☐ basement (walkout)
☐ crawlspace
☒ slab on grade Concrete
☐ piers
☐ piles
☒ posts/columns Metal posts
☒ other 8” thick concrete wall around whole structure (7’ in height)
STRUCTURAL SYSTEMS
4. Wall system (check all that apply):
Material
☒ frame (plaHorm) 2x6 wood (assumed)
☐ frame (balloon)
☐ masonry/stone (solid)
☐ monolithic/poured
☐ panel/manufactured
☐ other
5. Roof system (click all that apply):
Material
☒ frame 2X4 ra:ers
Double 2X8 posts spaced @
+/- 2’ along centerline of house. See plan.
☐ truss
☐ panel
☐ other
6. Signs of building damage or poten2al structural issue (check all that apply):
☐ founda�on se0lement
☒ cracking* ☐ dry rot ☐ termites ☐ other
☐ water damage/mold/sagging ☐ further inves�ga�on
7. Load bearing par22ons/posts (if applicable):
(5) Metal posts in basement along centerline of building, spaced around 7’-8’. See photos S9-10 for reference.
Large quan2ty of double 2x8 wood posts in roof along centerline of building. See photo S7 for reference.
Load bearing wall along centerline of building on main living level. See plan for loca2on.
8. Lateral resis2ng systems observed (if applicable) (NP):
Standard wood frame system.
9. Chimney connec2ons to structure (if applicable):
Vent stack connected to founda2on by concrete. See photo S6 for reference.
10. Structural support for a4ached porches, decks, etc. (if applicable):
(2) wood framed decks a4ached to building structure with nails. See photo S8 for reference.
11. Evidence of other upgrades or updates to the original structure?
Sump pump in corner of basement. See plan for loca2on. See photo S5 for reference.
*Some cracks on concrete wall around founda2on, appears to only be the covering. See photos S1-3 for reference.
Grade around building structure appears to be elevated, along with other site characteris2cs, including a concrete retaining wall in the front. See photo S4 for reference.
1. Energy sources (check all that apply):
☒ oil ☐ natural gas ☒electric ☐ propane ☐ wood burning
☐ solar
☐ other
1.a. Fuel storage tanks
Size/Quan�ty/Loca�on Below 1st Floor
☒ Oil, above-ground Basement ☐
☐ Oil, underground ☐
☐ tank fill & vent lines ☐
☐ LP, above ground ☐
1.b. Fuel system components (NP)
Loca�on Below 1st Floor
☐ LP regulator or NG meter/regulator ☐
☐ LP/NG service valve ☐
☐ Fuel oil or LP or NG service piping ☐
2. Interior u2li2es (check all that apply)
Below 1st Floor Level
2.a. HVAC Equipment
☒ furnace (oil) ☐
☐ furnace (gas) ☐
☐ air handling unit ☐
☒ ductwork ☐
☐ baseboard heaters (elec) ☐
☒ boiler (oil) ☐
☐ boiler (gas) ☐
☐ baseboard heaters (hot water) ☐
☐ radiators (steam) ☐
☒radiators (hot water) ☐
☐ radiators (electric) ☐
☐ hea�ng water piping ☐
☐ refrigerant piping ☐
☐ heat pump indoor unit ☐
☐ air condi�oning unit ☐
☐ wood stove ☐
☒ exhaust/flue rou�ng ☐
2b. Plumbing Equipment
☐ DHW heater (gas) ☐
☒ DHW heater (elec) ☐
☒ sump pump ☐
☒ sink ☐
☒ toilet ☐
☒ tub/shower ☐
☐ washer discharge ☐
☐ floor drain ☐
UTILITY
☐ pressure tank (well) ☐
☐ water filtra�on system ☐
☒ water service piping ☐
☒ drain (sewer) piping ☐
2c. Electrical Equipment
☒ elec. panel ☐
☐ elec. switches ☐
☐ elec. outlets ☐
☐ solar ba0ery ☐
☐ other ☐
3. Exterior u2li2es (check all that apply):
Below 1st Floor Level
3a. HVAC Equipment
☐ A/C compressor ☐
☒ heat pump outdoor unit ☐
☐ packaged unit ☐
☒ exhaust/flue rou�ng ☐
3b. Plumbing Equipment
☒ water meter ☐
☐ water service valve/box ☐
☐ water tank ☐
☐ water well/pump ☐
☐ sep�c tank ☐
☐ sep�c control panel ☐
☐ sep�c blower ☐
☐ irriga�on control panel ☐
3c. Electrical Equipment
☒ elec. meter ☐
☒ phone/cable junc�on box ☐
☐ satellite dish/TV antenna ☐
☐ generator ☐
☐ solar panel(s) ☐
☐ solar ba0ery ☐
☐ electric vehicle charging sta�on ☐
☒ fire, CO, or heat detector ☐ 3 CO
☒ quan�ty of fire/CO/heat detectors ☐
4. Are there connec2ng u2li2es to/from outbuildings or other structures? (NP)
5. Storm drainage (check all that apply):
Below 1st Floor Level
☒ downspouts, surface drain ☐
☐ downspouts, subsurface drain ☐
☐ other ☐
6. Water service:
Meter loca�on FRONT LAWN
Service entry loca�on BASEMENT NORTH OF HOUSE
7. Sewer service:
☒ Town Sewer ☐
☐ Sep�c ☐
Service discharge loca�on
8. Electrical power service:
9. Phone service:
☒ not applicable ☐ underground ☐ overhead
Building entry point
10. TV/fiber op2c service:
☐ not applicable ☐ underground ☐ overhead
☐ satellite dish/antenna Building entry point NORTH HOUSE
11. Photos:
Exterior Eleva�ons: ☒ Front ☒ Right ☒ Back ☒ Le:
Structural: ☒ Columns ☒ Beams ☒ Joist Framing ☒ Founda�on
☒ APc Framing ☒ Deck Framing
Electrical: ☒ Meter ☒ Panel ☐ U�lity Pole
Mechanical: ☒ Furnace/Boiler ☒ Hot Water Heater ☒ Pumps ☒ Water Meter
☐ A/C Compressor
Heat Pump/Split System: ☐ Ext. Unit ☐ Int. Unit ☐ Propane/Oil Tank
☐ underground ☐ overhead ☐ solar (primary) ☐ solar (supplemental)
Meter loca�on NORTH OF HOUSE
Meter number
U�lity Pole Number
Elec. panel loca�on BASEMENT NORTH OF HOUSE
Elec. panel size Main breaker size - 100A
Qty 1pole 15A breaker - 6
Qty 1pole 20A breaker - 8
Qty 2 pole breaker 30A breaker - 2
Qty AFCI breaker -
Qty GCFI breaker -
Other breaker - 2pole 15A, qty2; 2pole 40, qty1
Sub-panel loca�on
Qty 1pole 15A breaker -
Qty 1pole 20A breaker -
Qty 2 pole breaker 30A breaker -
Qty AFCI breaker -
Qty GCFI breaker -
Solar and/or generator disconnect loca�on ☐n/a
12. Others: (NP)
General Structural Condi�on Ra�ngs
EXCELLENT – Structure can be easily elevated or floodproofed (as applicable) without major altera"ons. No construc"on accessibility issues.
GREAT – Structure can be elevated or floodproofed (as applicable) without any major altera"ons. Minor construc"on accessibility issues.
GOOD – Structure can be elevated or floodproofed (as applicable) with some altera"ons. Moderate construc"on accessibility issues.
FAIR – Structure can be elevated or floodproofed (as applicable), but complex with many unknowns. Major construc"on accessibility issues.
POOR – Structure cannot be elevated or floodproofed (as applicable) without major altera"ons/repairs beyond the Government’s mandate.
GENERAL STRUCTURAL CONDITION:
☒Excellent ☐Great ☐Good ☐Fair ☐Poor
Are all exterior egress doors, windows, & garage doors (as applicable) fully operable & properly func�oning?
☒Yes ☐No
Are all interior doors fully operable & properly func�oning? ☒Yes ☐No
Are there any accessibility features present at any of the structure’s entrances? ☐Yes ☒No
Are there any indica�ons present/past termite infesta�on &/or termite damage? ☐Yes ☒No
Are there any surrounding features that may affect or be affected by eleva�ng or floodproofing (as applicable)?
☐None ☐Pool ☐Retaining Wall ☒Decks ☐Other:
PROFESSIONAL OPINION:
For residen�al buildings, is the exis�ng structure structurally sounds & capable of withstanding the stresses imposed by the eleva�ng process without substan�al improvements? ☒Yes ☐No ☐N/A
REVIEWED & APPROVED BY:
SIGNATURE:
PROFESSIONAL LICENSE NO. (WITH STATE INITIALS):
PROFESSIONAL DESIGN FIRM:
INSPECTION TEAM:
Edited/Reviewed by:
☒ Roger Newman
Jus2fica2on of General Structural Condi2on Assessment:
The building structure has no structural deficiencies present in any members, except for minor façade cracks on the exterior of the concrete founda2on. The founda2on and framing are uniform throughout the building structure. Two decks are present on either side of the building that will need to be raised, along with a vent stack in the rear.
BUILDING ELEVATION/FLOODPROOFING SUMMARY
DATE:
Floor Eleva on Survey Sheet
USACE TRACKING #: 9027 SURVEY DATE: 01/23/2025
ADDRESS: 64 Elder Drive COUNTY: Suffolk
CITY/TOWN: Mas�c Beach ZIP CODE: 11951
LEGAL DESCRIPTION AND/OR TAX PARCEL #:
0200-982.00-15.00-024.001, 472289 982.00-15-024.001
FOUNDATION TYPE: ☒Slab on Grade ☒Basement ☐Crawlspace ☐Elevated Without Enclosure on Post, Piles or Piers
☐Elevated With Enclosure on Post, Piles or Piers ☐Elevated With Enclosure Not on Post, Piles or Piers
FLOOD HAZARD ZONE(S): AE FEMA BASE FLOOD ELEVATION(S) (BFE): 6’-0” FEMA BFE + 2: 9’-6”
BENCHMARK UTILIZED: NAD 83 BM. VERTICAL DATUM: NAVD 88
BLDG. ELEV. DATUM: NAVD 88 OTHER: N/A
All Finish Floor Eleva�ons (FFE) to be taken at each exterior door threshold on the bo�om floor.
All eleva�ons to be provided in U.S. customary units to the nearest tenth of a survey foot.
If an item does not apply to the building, enter “N/A” for not applicable.
Datum used for building eleva�ons must be the same as that used for the BFE. Conversion factor used? ☐YES ☒NO
Conversion/Comments:
N/A
All measurements to be provided in U.S. customary units to the nearest ½ survey foot.
All calculated areas to be provided in U.S. customary units to the nearest 10 square feet.
If an item does not apply to the building, enter “N/A” for not applicable.
Square footage of first floor (excl. carports & detached porches): 1,040.62 square feet
Square footage of aAached garage: N/A square feet
Square footage of aAached decks and porches: North – 78.28
South – 10.70 square feet
Horizontal distance between the aAached garage & edge of road (i.e. driveway length): 49.45 feet
Horizontal distance between the front building line and nearest fence/property line: 45.12 feet
Horizontal distance between the right building line & nearest fence/property line: 11.48 feet
Horizontal distance between the leF building line & nearest fence/property line: 4.95 feet
• Horizontal distance between the rear building line & nearest fence/property line: 130.81 feet
BUILDING USE: ☐Commercial ☐Industrial ☒Residen�al Other:
LATITUDE: 40.753177 LONGITUDE: -72.852429
Top of the lowest floor (FFE): 3.73 (basement)
10.73 (first floor) feet
BoAom of the lowest horizontal structural member: Not observed feet
AAached garage (top of slab): N/A feet
Lowest eleva�on of Machinery & Equipment (M&E) servicing the building
(describe the type(s) of M&E and loca�on(s) in the Observa�ons & Notes Area):
Not observed feet
Lowest Adjacent Grade (LAG) next to building: ☒Natural ☐Finished 4.01 feet
Highest Adjacent Grade (HAG) next to building: ☒Natural ☐Finished 7.39 feet
Finished LAG at lowest eleva�on of aAached deck or stairs, including structural support: 4.56 feet
Edge of road pavement eleva�on at the driveway/roadway centerline-centerline intersec�on: 2.85 Feet
PROPERTY INFORMATION
ELEVATION SUMMARY
MEASUREMENT SUMMARY
ELEVATION PHOTOGRAPHS
FRONT
REAR
LEFT
RIGHT
ELEVATION PHOTOGRAPHS
UP
BASEMENT
+/- 42'-8"
+/- 22'-3"
UP
UP
DN
DN
LIVING ROOM
CL
+/- 10'-3"+/- 9'-0"
DN
+/- 11'-3" +/- 11'-3"
+/- 14'-4"+/- 5'-0"+/- 5'-0"+/- 17'-0"
+/- 11'-3" +/- 11'-3"
+/- 2'-1" +/- 3'-0"+/- 17'-0"
BEDROOM BEDROOM
BEDROOMDINING ROOM KITCHEN
BATH
ROOM
BATH
ROOM
CL
CL
CL
1/ 4"
'-0
R W
FA- R
W
E
LD
ER
D R
, M
AS
TI
C
B
EA
C H
, N Y, EX
IS
TI
N G
F
LO
O R
P
LA
N S
ST
R
U C
TU
R
E
ID
: 9
A-100
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
PL
O
T D
AT
E:
1 SCALE: 1/4" = 1'-0"
PROPOSED BASEMENT PLAN
2 SCALE: 1/4" = 1'-0"
PROPOSED FIRST FLOOR PLAN
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
SC
AL
E:
U
SA
C E
N
AN
R
IV
ER
IN
E
JO
IN
T
PA
R
TN
ER
S
A
R
LI
N G
TO
N
B
LV
D
FA
IR
FA
X, V
A
N ew
Y or k D is tri ct
F
ED
ER
AL
P
LA
ZA
N
EW
Y
O R
K, N
Y
W
2D S2
3D
/0
3/
AN
SI
D
W
2D S2
4F
FI
R
E
IS
LA
N
D
IN
LE
T
TO
M
O N
TA
U
K
PO
IN
T
(F
IM
P) C
O
AS
TA
L
ST
O
R M
R
IS
K R
E-
EV
AL
U
AT
IO
N N
O N
ST
R
U C
TU
R
AL
P
IL
O
T
BA
BY
LO
N
B R
O O
KH
AV
EN
N
EW
Y
O R
K
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
PL
O
T D
AT
E:
N
J un
8,
- 1
0:
am
UP
BASEMENT
+/- 42'-8"
+/- 22'-3"
UP
UP
DN
DN
LIVING ROOM
CL
+/- 10'-3"+/- 9'-0"
DN
+/- 11'-3" +/- 11'-3"
+/- 14'-4"+/- 5'-0"+/- 5'-0"+/- 17'-0"
+/- 11'-3" +/- 11'-3"
+/- 2'-1" +/- 3'-0"+/- 17'-0"
BEDROOM BEDROOM
BEDROOMDINING ROOM KITCHEN
BATH
ROOM
BATH
ROOM
CL
CL
CL
1/ 4"
'-0
R W
FA- R
W
E
LD
ER
D R
, M
AS
TI
C
B
EA
C H
, N Y, EX
IS
TI
N G
F
LO
O R
P
LA
N S
ST
R
U C
TU
R
E
ID
: 9
S-100
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
PL
O
T D
AT
E:
1 SCALE: 1/4" = 1'-0"
PROPOSED BASEMENT PLAN
2 SCALE: 1/4" = 1'-0"
PROPOSED FIRST FLOOR PLAN
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
SC
AL
E:
U
SA
C E
N
AN
R
IV
ER
IN
E
JO
IN
T
PA
R
TN
ER
S
A
R
LI
N G
TO
N
B
LV
D
FA
IR
FA
X, V
A
N ew
Y or k D is tri ct
F
ED
ER
AL
P
LA
ZA
N
EW
Y
O R
K, N
Y
W
2D S2
3D
/0
3/
AN
SI
D
W
2D S2
4F
FI
R
E
IS
LA
N
D
IN
LE
T
TO
M
O N
TA
U
K
PO
IN
T
(F
IM
P) C
O
AS
TA
L
ST
O
R M
R
IS
K R
E-
EV
AL
U
AT
IO
N N
O N
ST
R
U C
TU
R
AL
P
IL
O
T
BA
BY
LO
N
B R
O O
KH
AV
EN
N
EW
Y
O R
K
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
PL
O
T D
AT
E:
N
J un
8,
- 1
0:
am
USACE TRACKING #9027
rgnewman Snapshot rgnewman Rectangle rgnewman Text Box
RED TEXT = STRUCTURAL NOTES
BLUE TEXT = MEP NOTES
rgnewman Rectangle rgnewman Callout
150A ELECTRIC PANEL
rgnewman Callout
7' CONCRETE WALL
(TYP)
rgnewman Callout
METAL POST
(TYP FOR 5)
rgnewman Rectangle rgnewman Ellipse rgnewman Callout
DOMESTIC WATER SERVICE ENTRY
rgnewman Callout
APPROX. LOCATION OF SUMP PIT
rgnewman Rectangle rgnewman Rectangle rgnewman Callout
175 GAL FUEL OIL TANK
rgnewman Rectangle rgnewman Ellipse rgnewman Rectangle rgnewman Callout
SUMP PUMP
rgnewman Ellipse rgnewman Callout
APPROXIMATE SIZE AND LOCATION OF CONCRETE WALL
rgnewman Callout
40 GAL ELECTRIC WATER HEATER
rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Callout
BOILER
rgnewman Callout
VENT STACK
rgnewman Line rgnewman Line rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Text Box
LOAD BEARING CONCRETE WALL
rgnewman Text Box
LEGEND:
rgnewman Workpoint rgnewman Ellipse rgnewman Polygon rgnewman Polygon rgnewman Line rgnewman Line rgnewman Callout
SLAB ON GRADE
rgnewman Line rgnewman Line rgnewman Rectangle rgnewman Line rgnewman Line rgnewman Line rgnewman Rectangle rgnewman Rectangle rgnewman Line rgnewman Callout
VENT STACK
rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Line rgnewman Rectangle rgnewman Callout
HOT WATER BASBOARD HEATERS
rgnewman Rectangle rgnewman Text Box T rgnewman Rectangle rgnewman Ellipse rgnewman Text Box
EXTERIOR/LOAD BEARING WALL BELOW
rgnewman Rectangle rgnewman Ellipse rgnewman Ellipse rgnewman Line rgnewman Ellipse rgnewman Line rgnewman Text Box
CO
rgnewman Ellipse rgnewman Ellipse rgnewman Ellipse rgnewman Callout
METAL POSTS BELOW
(TYP)
rgnewman Rectangle rgnewman Line rgnewman Line rgnewman Text Box 2X6 @ 16" O.C.
(TYP)
rgnewman Text Box
CO
rgnewman Text Box
LEGEND:
rgnewman Ellipse rgnewman Line rgnewman Line rgnewman Line rgnewman Line rgnewman Rectangle rgnewman Text Box
WOOD JOIST SPAN DIRECTION
rgnewman Line rgnewman Rectangle rgnewman Rectangle rgnewman Line rgnewman Line rgnewman Text Box
CO
rgnewman Ellipse rgnewman Rectangle rgnewman Callout
ATTIC ENTRANCE
rgnewman Callout
FURNACE IN ATTIC SPACE
rgnewman Rectangle rgnewman Line rgnewman Line rgnewman Rectangle rgnewman Callout
ELECTRIC METER
rgnewman Rectangle rgnewman Callout
HEAT PUMP CONDENSER
rgnewman Rectangle rgnewman Line rgnewman Line rgnewman Rectangle rgnewman Line rgnewman Line rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Text Box
EXTERIOR/LOAD BEARING WALL BELOW
rgnewman Rectangle rgnewman Rectangle rgnewman Callout 2x4 RAFTERS 2x6 BRACING rgnewman Rectangle rgnewman Callout 2x8 WOOD POSTS @ 2' ALONG CENTERLINE rgnewman Line rgnewman Line rgnewman Line rgnewman Text Box
2X6 ASSUMED
SPAN NOT OBSERVED
rgnewman Arrow rgnewman Arrow rgnewman Text Box
DOWN
rgnewman Text Box
DOWN
rgnewman Line rgnewman Line rgnewman Line rgnewman Text Box
WOOD JOIST SPAN DIRECTION
rgnewman Text Box
LEGEND:
Special Considera�ons
USACE TRACKING #: 9027 ASSESSMENT DATE: 01/22/2025
1. Exis�ng central air system uses R410A type refrigerant.
ADDRESS: 64 Elder Dr COUNTY: Suffolk
CITY/TOWN: Mas�c Beach ZIP CODE: 11951
PROPERTY INFORMATION
SPECIAL CONSIDERATIONS
ID: #
ADDRESS: 64 Elder Dr.
Mastic Beach, NY 11951
DATE:
DESCRIPTION:
Exterior photo north facade facing Elder
Drive and of the staircase to main entry to the living room.
PHOTO: #A1
Mastic Beach, NY 11951
DESCRIPTION:
Exterior photo of the east facade
PHOTO: #A2
Structural Condition Assessment Summary- Appendix
USACE TRACKING #: 9027 ASSESSMENT DATE: 01/15/2025
Assessment Photographs
• Provide a descriptive caption with each photographic. Limit two photographs per page.
Mastic Beach, NY 11951
DATE:
Exterior photo of the north facade.
PHOTO: #A3
Exterior photo of the south facade and staircase providing direct entry to the dining room.
PHOTO: #A4
USACE TRACKING #: 9027 ASSESSMENT DATE: 01-15-2025
Mastic Beach, NY 11951
DATE:
DESCRIPTION:
Photo in basement's typical floor and wall conditions
PHOTO: #A5
Photo in basement's typical floor and wall conditions
PHOTO: #A6
Mastic Beach, NY 11951
DATE:
DESCRIPTION:
Photo of typical kitchen and dining floor conditions, wall and ceiling finishes.
PHOTO: #A7
Photo of kitchen cabinet, backsplash, wall and ceiling finishes
PHOTO: #A8
Mastic Beach, NY 11951
DATE:
DESCRIPTION:
Photo of bathroom floor, wall and ceiling finishes
PHOTO: #A9
Photo of bathroom's floor finishes
PHOTO: #A10
Mastic Beach, NY 11951
DATE:
DESCRIPTION:
.Photo of typical bedroom's floor and wall conditions.
PHOTO: #A11
Photo of typical Living Room floor and wall conditions.
PHOTO: #A12
ADDRESS: 64 Elder Dr
Mastic Beach, NY
11951
DATE: 01/22/2025
DESCRIPTION:
Cracking seen on the exterior façade of the foundation wall – around windows on the right side.
PHOTO: S#1-2
Mastic Beach, NY
11951
DATE: 01/22/2025
DESCRIPTION:
Cracking seen on the exterior façade of the foundation wall – on the left side.
PHOTO: S#3
Mastic Beach, NY
11951
DATE: 01/22/2025
DESCRIPTION:
Existing concrete wall in front of the building structure.
PHOTO: S#4
ADDRESS: 64 Elder Dr
Mastic Beach, NY
11951
DATE: 01/22/2025
DESCRIPTION:
Sump pump in the basement. See plan for location.
PHOTO: S#5
Mastic Beach, NY
11951
DATE: 01/22/2025
DESCRIPTION:
Vent stack attachment to foundation wall on rear of structure.
PHOTO: S#6
ADDRESS: 64 Elder Dr
Mastic Beach, NY
11951
DATE: 01/22/2025
DESCRIPTION:
Attic space with rafters and double wood posts along centerline of building shown.
Bracing (shown by arrow) present on the right of the posts.
PHOTO: S#7
Mastic Beach, NY
11951
DATE: 01/22/2025
DESCRIPTION:
Porch on left side attached to building structure through nailing.
PHOTO: S#8
Mastic Beach, NY
11951
DATE: 01/22/2025
DESCRIPTION:
Metal posts (5) in basement along centerline of building.
PHOTO: S#9-10
Mastic Beach, NY
11951
DATE: 01/22/2025
Main floor framing seen from basement.
PHOTO: S#11
Mastic Beach, NY
11951
DATE: 01/22/2025
Boiler located in basement.
PHOTO: M#1
Mastic Beach, NY
11951
DATE: 01/22/2025
DESCRIPTION:
Sump Pump located in the eastern basement.
PHOTO: M#2
Mastic Beach, NY
11951
DATE: 01/22/2025
DESCRIPTION:
Heat pump condenser unit located in the southeastern exterior area.
PHOTO: M#3
Mastic Beach, NY
11951
DATE: 01/22/2025
DESCRIPTION:
Electric panel located to the left of the front entrance.
PHOTO: M#4
| 64 Elder Dr, Mastic Beach plan |
| 20250115_64 Elder Drive, Mastic Beach_Basement (1) |
| 20250115_64 Elder Drive, Mastic Beach_First Floor (1) |
| Floor Elevation Survey Sheet - Rev01 |
| 64 Elder-041025 |
| Structural Condition Assessment Checklist - Rev02 |
| Structural Condition Assessment Summary - Photographs |
File details come from the government source that posted it. Updated .