This document comprises structural condition assessment checklists, floor elevation survey sheets, and accompanying architectural plans for 518 Riviera Drive, Mastic Beach, New York, prepared as part of the Fire Island Inlet to Montauk Point (FIMP) Coastal Storm Risk Re-Evaluation Nonstructural Pilot Project by the U.S. Army Corps of Engineers (USACE) New York District.

The subject property is a residential Cape Cod-style structure constructed in 1935 with a total building footprint of 1,305.55 square feet, located in FEMA flood zone AE with a base flood elevation (BFE) of 7'-0" and design flood elevation of 10'-6". The structural assessment, dated February 24, 2025, rated the property in "Excellent" condition, finding no major structural deficiencies, uniform foundation type (slab-on-grade with CMU knee walls and piers), and adequate connections between original and additional structures. The main floor features 2x6 joists at 16" on center with 2x8 girders, while the attached garage contains slab-on-grade flooring. The floor elevation survey, dated February 10, 2025, documented the top of the lowest finished floor at 4.29 feet and the attached garage slab at 2.53 feet above the vertical datum (NAVD 88). Special considerations identified include non-uniform foundation design, the need to lift two refrigerant condensers located on the north elevation currently at approximately 2.5 feet above grade, and the presence of R410A-type refrigerant in the central air system. The assessment includes detailed architectural floor plans, elevation photographs, structural framing diagrams, mechanical and electrical equipment locations, and 16 assessment photographs documenting exterior facades, interior conditions, crawlspace framing, and building systems.

View the file

Other files

File Type Posted
Solicitation Amendment W912DS26RA0070002 SF 30.pdf PDF
Part 6.03 - 15 Milton Rd, Babylon.pdf PDF
Part 6.03 - 24 Babylon Rd, Mastic Beach.pdf PDF
Part 6.03 - 94 Bayview, Mastic Beach.pdf PDF
Part 6.03 - 50 Montauk Dr, Mastic Beach.pdf PDF
Part 6.03 - 494 Riviera Dr, Mastic Beach.pdf PDF
Part 6.03 - 97 Huntington Dr, Mastic Beach.pdf PDF
Part 6.03 - 96 Huntington Dr, Mastic Beach.pdf PDF
Part 6.03 - 82 Huntington Dr, Mastic Beach.pdf PDF
Part 6.03 - 705 Riviera Dr, Mastic Beach.pdf PDF
Part 6.03 - 739 Riviera Dr, Mastic Beach.pdf PDF
Part 6.03 - 53 Pershing Ave, Babylon.pdf PDF
Part 6.10 Permits Record of Decision Form [M].pdf PDF
Part 6.05 - Home Types & Materials Matrix [I].pdf PDF
Part 6.03 - 39 W Harrison Ave, Babylon.pdf PDF
Part 6.03 - 4 Babylon Rd, Mastic Beach.pdf PDF
Part 6.03 - 4 Poplar Rd, Mastic Beach.pdf PDF
Part 6.03 - 17 Montauk Dr, Mastic Beach.pdf PDF
Part 6.03 - 11 Mitchell Ave, Babylon.pdf PDF
Part 6.03 - 10 Poplar Rd (Bldg 1), Mastic Beach (Structure 32343).pdf PDF
Part 6.03 - 100 S Bay Dr, Babylon.pdf PDF
Part 6.03 - 109 Hickory Rd, Mastic Beach.pdf PDF
Part 6.02 - Attachment B Design Requirements [M].pdf PDF
Part 6.01 - Attachment A - Summary of Eligible Houses [.pdf PDF
Solicitation Amendment W912DS26RA0070001 SF 30.pdf PDF
Part 6.03 - 6 Rosewood Rd, Mastic Beach.pdf PDF
Part 6.03 - 38 Montauk Dr, Mastic Beach.pdf PDF
Part 6.03 - 71 Laurelton Dr, Mastic Beach.pdf PDF
Part 6.03 - 70 S Bay Dr, Babylon.pdf PDF
Part 6.03 - 99 Bayview Dr, Mastic Beach.pdf PDF
Part 6.03 - 58 Huguenot Dr, Mastic Beach.pdf PDF
Part 6.03 - 61 Laurelton Dr, Mastic Beach.pdf PDF
Part 6.03 - 702 Riviera Dr, Mastic Beach.pdf PDF
Part 6.03 - 88 Huntington Dr, Mastic Beach.pdf PDF
Part 6.03 - 98 Bayview Dr, Mastic Beach.pdf PDF
Part 6.03 - 518 Riviera Dr, Mastic Beach.pdf PDF
Part 6.03 - 84 S Bay Dr, Babylon.pdf PDF
Part 6.03 - 450 Riviera Dr, Mastic Beach.pdf PDF
Part 6.03 - 23 W Harrison Ave, Babylon.pdf PDF
Part 6.03 - 15 Sheridan Rd, Babylon.pdf PDF
Part 6.03 - 17 Bayport Rd, Mastic Beach.pdf PDF
Part 6.03 - 100 Huntington Dr, Mastic Beach.pdf PDF
Part 6.03 - 105 Bayview Dr, Mastic Beach.pdf PDF
Part 6.03 - 100 Hickory Rd, Mastic Beach.pdf PDF
Part 2 - General Requirements.pdf PDF
Final DB RFP Table of Contents.pdf PDF
Part 6 Table of Contents.pdf PDF
Part 3 - Project Program.pdf PDF
Evaluation Factors R2.pdf PDF
Solicitation - W912DS26RA007 Final.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Structural Condi�on Assessment Checklist

FIMP Pilot Project – Babylon and Brookhaven

USACE TRACKING #: 6129 ASSESSMENT DATE: 02-24-2025

1. Exterior finish materials (check all that apply. NP indicates Not Present):

☒ siding ☐ masonry ☐ masonry veneer* ☐ stone ☐ stone veneer

☐ �mber/wood ☐ wood shake ☐ concrete ☐ other

Typical shake/siding exposure:

*Note: where veneer is supported

2. Building access points (check all that apply):

Stairs Material(s) & Step Qty

☒ front ☒ Wood, 2 Steps

☒ side (left) ☒ Concrete, 2 Steps

☒ side (right) ☐

☐ back ☐

☐ interior (attached garage) ☐

☐ interior (basement) ☐

☐ basement bulkhead ☐

☒ crawlspace access ☒ CMU block to grade

☐ other ☐

3. Addi2on/a4achment number and size (check all that apply):

Quan�ty Area

☒ porch/pa�o (uncovered) 1 East – 42.49 SF

☐ porch/pa�o (covered)

☐ porch/pa�o (enclosed)

☒ deck (w/steps to grade)

West – 30.19 SF

North – 558.8 SF

East wrap around – 241.98 SF

☐ deck (w/out steps to grade)

☐ chimney (interior)

☐ chimney (exterior)

☐ garage (integral)

☐ garage (a3ached, adjacent)

☐ garage (a3ached, breezeway)

ADDRESS: 518 Riviera Drive COUNTY: Suffolk

CITY/TOWN: Mas�c Beach ZIP CODE: 11951

HOMEOWNER NAMES:

POC EMAIL: POC PHONE:

BASE FLOOD ELEVATION (BFE): 7’-0” DESIGN FLOOD ELEVATION (DFE): 10’-6”

ZONE: AE YEAR CONSTRUCTED: 1935

TOTAL AREA OF BUILDING FOOTPRINT (SF): 1305.55 MAXIMUM BUILDING HEIGHT ALLOWED: 35 ?

PROPERTY INFORMATION

GENERAL INFORMATION

USACE TRACKING #6129

☐ addi�on (interior access)

☐ addi�on (exterior access only)

☐ other

4. Accessible features (check all that apply): (NP)

☐ ramp ☐ chair li; ☐ hydraulic li; ☐ elevator ☐ other

5. Exterior improvements in work area (check all that apply):

☒ driveway ☒ pa�o/pavers ☐ retaining wall ☐ sidewalk ☒ landscaping

☐ pool/hot tub ☐ fence/gate ☐ other

6. Home Type

☐ Cape Cod ☐ Ranch ☐ Split Level ☐ Bungalow ☐ Cra;sman

☐ Co1age ☐ Farmhouse ☒ other

USACE TRACKING #6219

1. Approximate eleva2ons:

Top of founda�on +/- 8” above grade

Floor of basement / crawlspace +/- 1’-4” below grade

Lowest Struct Member Measured up from founda�on +/- 2’-0”

Floor of main living level +/- 1’-4” above grade

Floor of lowest living level +/- 1’-4” above grade

Floor of second floor +/- 10’-0” above grade (assumed)

Other A1ached garage – at grade

2. Floor system:

2.a. Main floor Framing towards the west side not observed. See plan.

Framing Size & Spacing East side: joist - 2x6 @ 16” O.C.

Girder – 2x8

Framing Type Wood framing

Framing Direc�on See plan

2.b. Second floor

Framing Size & Spacing Not observed

Framing Type Wood framing (assumed)

Framing Direc�on See plan

3. Founda2on type (check all that apply):

Material

☐ basement (subgrade)

☐ basement (walkout)

☒ crawlspace CMU knee wall

☐ slab on grade

☒ piers CMU piers

☐ piles

☐ posts/columns

☐ other

STRUCTURAL SYSTEMS

4. Wall system (check all that apply):

Material

☒ frame (plaAorm) Wood framing (assumed)

☐ frame (balloon)

☐ masonry/stone (solid)

☐ monolithic/poured

☐ panel/manufactured

☐ other

5. Roof system (click all that apply):

Material

☒ frame Original roofing not observed

Garage: 2x6 ridge

Ra;er – 2x6 @ 20” O.C.

☐ truss

☐ panel

☐ other

6. Signs of building damage or poten2al structural issue (check all that apply):

☐ founda�on se1lement

☒ cracking ☐ dry rot ☐ termites ☐ other

☐ water damage/mold/sagging ☐ further inves�ga�on

7. Load bearing par22ons/posts (if applicable):

(2) load bearing par22ons were found:

- Next to the stairs spanning from north to south.

- Located at the dining room with connected header beam above. See plan.

8. Lateral resis2ng systems observed (if applicable):

Standard wood frame system.

9. Chimney connec2ons to structure (if applicable):

Vent above the roof near the north side of the building.

10. Structural support for a4ached porches, decks, etc. (if applicable):

Wood deck at the south entrance. Structural support not observed. See plan.

Concrete deck at the north entrance. See plan.

11. Evidence of other upgrades or updates to the original structure?

A4ached boiler room and garage at the north side of the building with slab-on-grade. See plan.

1. Energy sources (check all that apply):

☐ oil ☐ natural gas ☒ electric ☐ propane ☐ wood burning

☐ solar

☐ other

1.a. Fuel storage tanks (NP)

Size/Quan�ty/Loca�on Below 1st Floor

☐ Oil, above-ground ☐

☐ Oil, underground ☐

☐ tank fill & vent lines ☐

☐ LP, above ground ☐

1.b. Fuel system components (NP)

Loca�on Below 1st Floor

☐ LP regulator or NG meter/regulator ☐

☐ LP/NG service valve ☐

☐ Fuel oil or LP or NG service piping ☐

2. Interior u2li2es (check all that apply)

Below 1st Floor Level

2.a. HVAC Equipment

☐ furnace (oil) ☐

☐ furnace (gas) ☐

☐ air handling unit ☐

☐ ductwork ☐

☐ baseboard heaters (elec) ☐

☐ boiler (oil) ☐

☐ boiler (gas) ☐

☐ baseboard heaters (hot water) ☐

☐ radiators (steam) ☐

☐ radiators (hot water) ☐

☐ radiators (electric) ☐

☐ hea�ng water piping ☐

☒ refrigerant piping ☒

☒ heat pump indoor unit ☒

☐ air condi�oning unit ☐

☐ wood stove ☐

☒ exhaust/flue rou�ng ☒

2b. Plumbing Equipment

☐ DHW heater (gas) ☐

☒ DHW heater (elec) ☒

☐ sump pump ☐

☒ sink ☒

☒ toilet ☒

☒ tub/shower ☒

☒ washer discharge ☒

☐ floor drain ☐

UTILITY

☐ pressure tank (well) ☐

☐ water filtra�on system ☐

☐ water service piping ☐

☐ drain (sewer) piping ☐

2c. Electrical Equipment

☒ elec. panel ☒

☒ elec. switches ☒

☒ elec. outlets ☒

☐ solar ba1ery ☐

☐ other ☐

3. Exterior u2li2es (check all that apply):

Below 1st Floor Level

3a. HVAC Equipment

☐ A/C compressor ☐

☒ heat pump outdoor unit ☒

☐ packaged unit ☐

☐ exhaust/flue rou�ng ☐

3b. Plumbing Equipment (NP)

☐ water meter ☐

☐ water service valve/box ☐

☐ water tank ☐

☐ water well/pump ☐

☐ sep�c tank ☐

☐ sep�c control panel ☐

☐ sep�c blower ☐

☐ irriga�on control panel ☐

3c. Electrical Equipment

☒ elec. meter ☒

☐ phone/cable junc�on box ☐

☐ satellite dish/TV antenna ☐

☐ generator ☐

☐ solar panel(s) ☐

☐ solar ba1ery ☐

☐ electric vehicle charging sta�on ☐

☒ fire, CO, or heat detector ☒

☒ quan�ty of fire/CO/heat detectors ☒ 3

4. Are there connec2ng u2li2es to/from outbuildings or other structures? NP

Not applicable

5. Storm drainage (check all that apply): NP

Below 1st Floor Level

☐ downspouts, surface drain ☐

☐ downspouts, subsurface drain ☐

☐ other ☐

6. Water service: NP

Meter loca�on

Service entry loca�on

7. Sewer service:

☒ Town Sewer ☒

☐ Sep�c ☐

Service discharge loca�on

8. Electrical power service:

9. Phone service:

☒ not applicable ☐ underground ☐ overhead

Building entry point

10. TV/fiber op2c service:

☒ not applicable ☐ underground ☐ overhead

☐ satellite dish/antenna Building entry point

11. Photos:

Exterior Eleva�ons: ☒ Front ☒ Right ☒ Back ☒ Le;

Structural: ☐ Columns ☐ Beams ☒ Joist Framing ☒ Founda�on

☐ AMc Framing ☐ Deck Framing

Electrical: ☐ Meter ☐ Panel ☐ U�lity Pole

Mechanical: ☐ Furnace/Boiler ☒ Hot Water Heater ☐ Pumps ☐ Water Meter

☐ A/C Compressor

Heat Pump/Split System: ☒ Ext. Unit ☒ Int. Unit ☐ Propane/Oil Tank

☐ underground ☐ overhead ☐ solar (primary) ☐ solar (supplemental)

Meter loca�on On side of garage

Meter number

U�lity Pole Number

Elec. panel loca�on

Elec. panel size Main breaker size – 200A

Qty 1pole 15A breaker - 10

Qty 1pole 20A breaker - 7

Qty 2 pole breaker 30A breaker - 2

Qty AFCI breaker -

Qty GCFI breaker -

Other breaker -2 Pole 50A breaker- 1, 2 Pole 20A breaker- 2

Sub-panel loca�on

Qty 1pole 15A breaker -

Qty 1pole 20A breaker -

Qty 2 pole breaker 30A breaker -

Qty AFCI breaker -

Qty GCFI breaker -

Solar and/or generator disconnect loca�on ☐n/a

12. Others:

Not applicable.

General Structural Condi�on Ra�ngs

EXCELLENT – Structure can be easily elevated or floodproofed (as applicable) without major altera"ons. No construc"on accessibility issues.

GREAT – Structure can be elevated or floodproofed (as applicable) without any major altera"ons. Minor construc"on accessibility issues.

GOOD – Structure can be elevated or floodproofed (as applicable) with some altera"ons. Moderate construc"on accessibility issues.

FAIR – Structure can be elevated or floodproofed (as applicable), but complex with many unknowns. Major construc"on accessibility issues.

POOR – Structure cannot be elevated or floodproofed (as applicable) without major altera"ons/repairs beyond the Government’s mandate.

GENERAL STRUCTURAL CONDITION:

☒Excellent ☐Great ☐Good ☐Fair ☐Poor

Are all exterior egress doors, windows, & garage doors (as applicable) fully operable & properly func�oning?

☒Yes ☐No

Are all interior doors fully operable & properly func�oning? ☒Yes ☐No

Are there any accessibility features present at any of the structure’s entrances? ☐Yes ☒No

Are there any indica�ons present/past termite infesta�on &/or termite damage? ☐Yes ☒No

Are there any surrounding features that may affect or be affected by eleva�ng or floodproofing (as applicable)?

☐None ☐Pool ☐Retaining Wall ☒Decks ☒Other: Mech. equipment

PROFESSIONAL OPINION:

For residen�al buildings, is the exis�ng structure structurally sounds & capable of withstanding the stresses imposed by the eleva�ng process without substan�al improvements? ☒Yes ☐No ☐N/A

REVIEWED & APPROVED BY:

SIGNATURE:

PROFESSIONAL LICENSE NO. (WITH STATE INITIALS):

PROFESSIONAL DESIGN FIRM:

INSPECTION TEAM:

Edited/Reviewed by:

☒ Jinhua Ma

Jus2fica2on of General Structural Condi2on Assessment:

- No major structural deficiencies were found during visual structural inspec�on.

- Founda�on type was found to be uniform except storage room located in the a1ached garage which is slab-on-grade.

- No connec�on issues were found between the original and the addi�onal part of the structure.

- No accessible issues were found at the entrances.

BUILDING ELEVATION/FLOODPROOFING SUMMARY

DATE:

Floor Eleva on Survey Sheet

USACE TRACKING #: 6129 SURVEY DATE: 02/10/2025

ADDRESS: 518 Riviera Dr COUNTY: Suffolk

CITY/TOWN: Mas�c Beach ZIP CODE: 11951

LEGAL DESCRIPTION AND/OR TAX PARCEL #:

0200-983.50-03.00-016.001, 472289 983.50-03-016.001

FOUNDATION TYPE: ☒Slab on Grade ☐Basement ☒Crawlspace ☐Elevated Without Enclosure on Post, Piles or Piers

☐Elevated With Enclosure on Post, Piles or Piers ☐Elevated With Enclosure Not on Post, Piles or Piers

FLOOD HAZARD ZONE(S): AE FEMA BASE FLOOD ELEVATION(S) (BFE): 7’-0” FEMA BFE + 2: 10’-6”

BENCHMARK UTILIZED: NAD 83 BM. VERTICAL DATUM: NAVD 88

BLDG. ELEV. DATUM: NAVD 88 OTHER: N/A

All Finish Floor Eleva�ons (FFE) to be taken at each exterior door threshold on the bo�om floor.

All eleva�ons to be provided in U.S. customary units to the nearest tenth of a survey foot.

If an item does not apply to the building, enter “N/A” for not applicable.

Datum used for building eleva�ons must be the same as that used for the BFE. Conversion factor used? ☐YES ☒NO

Conversion/Comments:

N/A

All measurements to be provided in U.S. customary units to the nearest ½ survey foot.

All calculated areas to be provided in U.S. customary units to the nearest 10 square feet.

If an item does not apply to the building, enter “N/A” for not applicable.

Square footage of first floor (excl. carports & detached porches): 1305.55 square feet

Square footage of aBached garage: 340.41 square feet

Square footage of aBached decks and porches: 42.49(east), 30.19(west), 558.8(north), 241.98(east wrap around) square feet

Horizontal distance between the aBached garage & edge of road (i.e. driveway length): 38.06 feet

Horizontal distance between the front building line and nearest fence/property line: 31.81 feet

Horizontal distance between the right building line & nearest fence/property line: 47.60 feet

Horizontal distance between the leF building line & nearest fence/property line: 12.87 feet

Horizontal distance between the rear building line & nearest fence/property line: 63.04 feet

BUILDING USE: ☐Commercial ☐Industrial ☒Residen�al Other:

LATITUDE: 40.751906 LONGITUDE: -72.846717

Top of the lowest floor (FFE): 4.29 feet

BoBom of the lowest horizontal structural member: N/A feet

ABached garage (top of slab): 2.53 feet

Lowest eleva�on of Machinery & Equipment (M&E) servicing the building

(describe the type(s) of M&E and loca�on(s) in the Observa�ons & Notes Area):

N/A feet

Lowest Adjacent Grade (LAG) next to building: ☐Natural ☒Finished 2.46 feet

Highest Adjacent Grade (HAG) next to building: ☒Natural ☐Finished 3.30 feet

Finished LAG at lowest eleva�on of aBached deck or stairs, including structural support: N/A feet

Edge of road pavement eleva�on at the driveway/roadway centerline-centerline intersec�on: 2.24 feet

PROPERTY INFORMATION

ELEVATION SUMMARY

MEASUREMENT SUMMARY

USACE TRACKING #6129

ELEVATION PHOTOGRAPHS

FRONT

REAR

LEFT

RIGHT

ELEVATION PHOTOGRAPHS

O

R

DW

DINING ROOM

KITCHEN

OFFICE

WATER

HEATER

ENTRY

LIVING ROOM

BEDROOM

BEDROOM

3/

'-0

R W

FA- R

W

R

IV

IE

R

A D

R

IV

E, M

AS

TI

C B

EA

C

H , N

Y, EX

IS

TI

N

G F

LO

O

R P

LA

N

S

ST

R U

C

TU

R E

ID

: 6

A-100

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

PL

O

T D

AT

E:

1 SCALE: 3/16" = 1'-0"

PROPOSED FIRST FLOOR PLAN

2 SCALE: 3/16 = 1'-0"

PROPOSED SECOND FLOOR PLAN

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SU

BM

IT

TE

D B

Y:

C H

EC

KE

D B

Y:

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

IS

SU

E D

AT

E:

SI

ZE

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E

SHEET ID

SC

AL

E:

U

SA

C E

N

AN

R

IV

ER

IN

E

JO

IN

T

PA

R

TN

ER

S

A

R

LI

N G

TO

N

B

LV

D

FA

IR

FA

X, V

A

N ew

Y or k D is tri ct

F

ED

ER

AL

P

LA

ZA

N

EW

Y

O R

K, N

Y

W

2D S2

3D

/0

3/

AN

SI

D

W

2D S2

4F

FI

R

E

IS

LA

N

D

IN

LE

T

TO

M

O N

TA

U

K

PO

IN

T

(F

IM

P) C

O

AS

TA

L

ST

O

R M

R

IS

K R

E-

EV

AL

U

AT

IO

N N

O N

ST

R

U C

TU

R

AL

P

IL

O

T

BA

BY

LO

N

B R

O O

KH

AV

EN

N

EW

Y

O R

K

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

PL

O

T D

AT

E:

N

J un

8,

- 1

0:

am

O

R

DW

DINING ROOM

KITCHEN

OFFICE

WATER

HEATER

ENTRY

LIVING ROOM

BEDROOM

BEDROOM

3/

'-0

R W

FA- R

W

R

IV

IE

R

A D

R

IV

E, M

AS

TI

C B

EA

C

H , N

Y, EX

IS

TI

N

G F

LO

O

R P

LA

N

S

ST

R U

C

TU

R E

ID

: 6

S-100

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

PL

O

T D

AT

E:

1 SCALE: 3/16" = 1'-0"

PROPOSED FIRST FLOOR PLAN

2 SCALE: 3/16 = 1'-0"

PROPOSED SECOND FLOOR PLAN

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SU

BM

IT

TE

D B

Y:

C H

EC

KE

D B

Y:

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

IS

SU

E D

AT

E:

SI

ZE

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E

SHEET ID

SC

AL

E:

U

SA

C E

N

AN

R

IV

ER

IN

E

JO

IN

T

PA

R

TN

ER

S

A

R

LI

N G

TO

N

B

LV

D

FA

IR

FA

X, V

A

N ew

Y or k D is tri ct

F

ED

ER

AL

P

LA

ZA

N

EW

Y

O R

K, N

Y

W

2D S2

3D

/0

3/

AN

SI

D

W

2D S2

4F

FI

R

E

IS

LA

N

D

IN

LE

T

TO

M

O N

TA

U

K

PO

IN

T

(F

IM

P) C

O

AS

TA

L

ST

O

R M

R

IS

K R

E-

EV

AL

U

AT

IO

N N

O N

ST

R

U C

TU

R

AL

P

IL

O

T

BA

BY

LO

N

B R

O O

KH

AV

EN

N

EW

Y

O R

K

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

PL

O

T D

AT

E:

N

J un

8,

- 1

0:

am

USACE TRACKING #6219

rgnewman Snapshot rgnewman Text Box

LEGEND:

rgnewman Rectangle rgnewman Text Box

LOAD BEARING CMU KNEE WALL BELOW

rgnewman Rectangle rgnewman Text Box

ADDITION

rgnewman Rectangle rgnewman Text Box

APPROX LOC. OF CMU PIER BELOW

SITTING ON CONC FOOTING

rgnewman Polygon rgnewman Rectangle rgnewman Workpoint rgnewman Ellipse rgnewman Polygon rgnewman Polygon rgnewman Line rgnewman Line rgnewman Callout

SLAB ON GRADE

rgnewman Workpoint rgnewman Ellipse rgnewman Polygon rgnewman Polygon rgnewman Line rgnewman Line rgnewman Callout

+/- 1'-4" T.O. SLAB ON GRADE

rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Callout

2X8 GIRDER BELOW

rgnewman Line rgnewman Line rgnewman Line rgnewman Text Box 2X6 @ 16" O.C.

rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Callout 2x8 GIRDER BELOW rgnewman Line rgnewman Line rgnewman Line rgnewman Text Box

ASSUMED

rgnewman Text Box

RED TEXT = STRUCTURAL NOTES

BLUE TEXT = MEP NOTES

rgnewman Text Box

GARAGE

rgnewman Rectangle rgnewman Callout

ASSUME GIRDER BELOW

rgnewman Rectangle rgnewman Callout

ASSUME CMU PIER BELOW

rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Arrow rgnewman Text Box

DN

rgnewman Workpoint rgnewman Ellipse rgnewman Polygon rgnewman Polygon rgnewman Line rgnewman Line rgnewman Callout

T.O. CONC DECK

+/- 1'-4" ABOVE GRADE

rgnewman Rectangle rgnewman Rectangle rgnewman Arrow rgnewman Text Box

DN

rgnewman Workpoint rgnewman Ellipse rgnewman Polygon rgnewman Polygon rgnewman Line rgnewman Line rgnewman Callout

T.O. WOOD DECK

+/- 1'-4" ABOVE GRADE

rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Callout

SPLIT SYSTEM INDOOR AC UNIT

rgnewman Rectangle rgnewman Rectangle rgnewman Callout

SPLIT SYSTEM OUTDOOR CONDENSER

rgnewman Rectangle rgnewman Rectangle rgnewman Callout

ELECTRICAL PANEL

rgnewman Callout

ELECTRICAL METER

rgnewman Ellipse rgnewman Callout

DOMESTIC HOT WATER HEATER

rgnewman Text Box

SD

rgnewman Ellipse rgnewman Text Box

SD

rgnewman Ellipse rgnewman Line rgnewman Line rgnewman Line rgnewman Text Box

WOOD FRAMING SPAN DIRECTION

rgnewman Polygon rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Line rgnewman Callout

2X6 ROOF RIDGE

rgnewman Text Box

RAFTER SPAN

2X6 @ 20" O.C.

rgnewman Arrow rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Callout

HEADER BELOW

rgnewman Line rgnewman Line rgnewman Line rgnewman Text Box

ASSUMED

rgnewman Line rgnewman Line rgnewman Line rgnewman Text Box

ASSUMED

rgnewman Text Box

LEGEND:

rgnewman Rectangle rgnewman Text Box

ADDITION

rgnewman Rectangle rgnewman Text Box

EXTERIOR/LOAD BEARING WALL BELOW

rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Callout

CEILING CRACKS BELOW

rgnewman Line rgnewman Line rgnewman Line rgnewman Text Box

WOOD FRAMING SPAN DIRECTION

rgnewman Text Box

LOCATION OF WHERE SIGN OF BUILDING DAMAGE WAS FOUND

rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Rectangle rgnewman Line rgnewman Callout

ROOF RIDGE

rgnewman Arrow rgnewman Text Box

RAFTER SPAN

ASSUMED

rgnewman Rectangle rgnewman Callout

SPLIT SYSTEM INDOOR AC UNIT

rgnewman Rectangle rgnewman Callout

SPLIT SYSTEM INDOOR AC UNIT

rgnewman Text Box

SD

rgnewman Ellipse

Special Considera�ons

USACE TRACKING #: 6219 ASSESSMENT DATE: 02/24/2025

1. Founda�on was found be non-uniform. Founda�on in the storage room area was slab-on-grade. See plan.

2. 2 condensers located on the north side of the building need to be li*ed. See plan. See photo M#2.

3. Exis�ng central air system uses R410A type refrigerant.

ADDRESS: 518 Riviera Dr COUNTY: Suffolk

CITY/TOWN: Mas�c Beach ZIP CODE: 11951

PROPERTY INFORMATION

SPECIAL CONSIDERATIONS

Structural Condi�on Assessment Summary- Appendix

USACE TRACKING #: 6219 ASSESSMENT DATE: 02/17/2025

• Provide a descrip�ve cap�on with each photographic. Limit two photographs per page.

ID: #

ADDRESS: 518 Riviera Dr, Mas�c

Beach, NY, 11951

DATE: 02/17/2025

DESCRIPTION:

Exterior photo of northeast façade showing steps up to main entrance.

PHOTO: A#1

Exterior photo of raised deck and access to side entrance.

PHOTO: A#2

Assessment Photographs

Exterior photo of south façade showing raised walkway.

PHOTO: A#3

Exterior photo of southeast façade showing steps up to back entrance.

PHOTO: A#4

Interior photo showing kitchen cabinets and typical le flooring and back splash.

PHOTO: A#5

Interior photo of bathroom showing le flooring and led wall.

PHOTO: A#6

Interior photo at garage showing steps down to slab of grade.

PHOTO: A#7

Interior photo at second floor showing typical wood flooring.

PHOTO: A#8

Interior photo at second floor bathroom showing le flooring and wall les.

PHOTO: A#9

Structural Condi�on Assessment Summary - Appendix

Beach, NY 11951

DATE: 02/24/2025

DESCRIPTION: Crawlspace

Wood framing below the east part of the building. Joist spanning from east to west

Joists: 2x6 @ 16” O.C.

Girder: 2x8

PHOTO: S#1

ID: #

ADDRESS: 518 Riviera Dr, Mas�c

Beach, NY 11951

DATE: 02/24/2025

DESCRIPTION: Crawlspace

The arrows are poin ng at the CMU pier and 2x8 girder located near the center of the building. CMU knee wall was found behind.

Crawlspace was not accessible on the west side of the building.

PHOTO: S#2

Beach, NY 11951

DESCRIPTION: 1st Fl

Ceiling crack

PHOTO: S#3

ID: #

ADDRESS: 518 Riviera Dr, Mas�c

Beach, NY 11951

DESCRIPTION: Exterior – north side

The red arrow is poin ng at the crack on the vent

PHOTO: S#4

Beach, NY 11951

DESCRIPTION: Garage

Roof framing above the a2ached garage.

Ridge: 2x6

Ra3ers: 2x6 @ 20” O.C.

PHOTO: S#5

Beach, NY 11951

DATE: 02/24/2025

DESCRIPTION:

Refrigerant lines running along the side of the house from the condenser to indoor ac units.

PHOTO: M#1

ADDRESS: 518 Riviera Dr, Mas�c

Beach, NY 11951

DATE: 02/24/2025

DESCRIPTION:

Split system outdoor condenser units.

Mounted approximately 2.5’ above grade.

PHOTO: M#2

Beach, NY 11951

DATE: 02/24/2025

DESCRIPTION:

Electrical meter next to split system outdoor condenser unit.

PHOTO: M#3

ADDRESS: 518 Riviera Dr, Mas�c

Beach, NY 11951

DATE: 02/24/2025

DESCRIPTION:

Electrical panel located on the inside wall of garage

PHOTO: M#4

Beach, NY 11951

DATE: 02/24/2025

DESCRIPTION:

Refrigerant lines running along the side of the house from the condenser to indoor ac units.

PHOTO: M#5

ADDRESS: 518 Riviera Dr, Mas�c

Beach, NY 11951

DATE: 02/24/2025

DESCRIPTION:

Split system indoor unit located in living room

PHOTO: M#6

File details come from the government source that posted it. Updated .