About this file

This document is an architectural drawing sheet (A-002) from the US Army Corps of Engineers for a repair project at Building 606 at United States Military Academy, West Point, NY. The sheet contains detailed dimensioning legends, general architectural notes, and a comprehensive schedule of miscellaneous accessories and equipment mounting heights. Key details include specifications for fire extinguisher cabinets from JL Industries, coat hooks from Camden-Boone, and mounting height guidelines for various fixtures like chalk boards, white boards, toilet paper dispensers, and accessibility features. The project is part of contract W912DS19C0034, with an issue date of 2 September 2025 and an addendum (#6) dated 10 October 2025, indicating an ongoing design refinement process. The drawing provides precise technical guidance for installation of building elements, with specific attention to accessibility standards and mounting requirements.

View the file

Other files

File Type Posted
Solicitation Amendment W912DS25RA0020009 SF 30.pdf PDF
Solicitation Amendment W912DS25RA0020008 SF 30.pdf PDF
E-512_AM 7.pdf PDF
I-108_AM 6.pdf PDF
I-105_AM 6.pdf PDF
I-100.3_AM 6.pdf PDF
I-100.2_AM 6.pdf PDF
AD-101_AM 6.pdf PDF
A-304_AM 6.pdf PDF
A-315_AM 6.pdf PDF
A-503_AM 6.pdf PDF
A-003_AM 6.pdf PDF
H-103_AM 6.pdf PDF
H-104_AM 6.pdf PDF
H-102_AM 6.pdf PDF
H-001_AM 6.pdf PDF
H-108_AM 6.pdf PDF
MP-102_AM 6.pdf PDF
MH-104_AM 6.pdf PDF
M-505_AM 6.pdf PDF
S-316_AM 6.pdf PDF
S-311_AM 6.pdf PDF
S-310_AM 6.pdf PDF
S-113_AM 6.pdf PDF
S-110_AM 6.pdf PDF
S-109_AM 6.pdf PDF
S-001_AM 6.pdf PDF
Submittal Register_AM 6.pdf PDF
Appendix G_AM 5.pdf PDF
A-602_AM 4.pdf PDF
A-564_AM 4.pdf PDF
A-601_AM 4.pdf PDF
Solicitation Amendment W912DS25RA0020004 SF 30.pdf PDF
M-303_AM3.pdf PDF
E-512 - DETAILS - ELECTRICAL_AM3.pdf PDF
MSEC- Building 606 - Amendment 3 - RFIs - 16 Sep 25.pdf PDF
Solicitation Amendment W912DS25RA0020003 SF 30.pdf PDF
MS-100_AM3.pdf PDF
01 91 19_AM3.pdf PDF
01 30 00_AM3.pdf PDF
A-319.pdf PDF
E-513.pdf PDF
A-121.pdf PDF
07 60 00.pdf PDF
Solicitation Amendment W912DS25RA0020001 SF 30.pdf PDF
MSEC- Building 606 - Amendment 1 - RFIs - 20 Aug 25.pdf PDF
JA-007-25 Monaco Fire Alarm MSEC - 31 Jan 25 signedJF sDL_Redacted.pdf PDF
W912DS19C0034 PN 94078 Repair Building 606 Revised RTA Drawings - Volume 4.pdf PDF
W912DS19C0034 PN 94078 Repair building 606 REV.RTA Specification Manual Volume 3.pdf PDF
W912DS19C0034 PN 94078 Repair building 606 REV.RTA Specification Manual Volume 1.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1' A B

FOR DOOR OPENING

INFORMATION SEE

DOOR SCHEDULE

2"

7' - 4" 4' - 8"1

3'

0"1' - 8 1/4" 5 3/4"

FINISHED FACE OF

NON-MASONRY

WALL

NOMINAL FACE OF

MASONRY WALL

3 B

6 A

6 A

1 A

C8

A-002

1'

6"

1'

4" 8"

EL SECTION

8" 1'

4"

2'

0"

TOP OF MASONRY

UNIT BEYOND

ACTUAL FACE

OF MASONRYF

R O

M E

LE

V

A T

IO

N

B

SE

E

P

LA

N

3/ 8"

2"

33 ACTUAL FACE

OF MASONRY

NOMINAL DIMENSION

FROM PLAN

1/2" JT WIDTH

FACE OF

FINISHED

SURFACE

FROM PLAN

NOMINAL DIM

FROM PLAN

NOMINAL

MASONRY OPNG

1'

6"

SOAP

DISH

MIRROR

ACC-MOUNTHT-TUB-SHOWER ANSI 2009

(R

EC

O M

M

3'

6"

2'

6" M

IN

2'

CL

EXCEPTION:

24" GRAB BAR IS PERMITTED DUE

TO A RECESSED FIXTURE

ADJACENT TO WATER CLOSET.

SANITARY

NAPKIN

DISPOSAL

SIDE WALL GRAB BAR

FOR WATER CLOSET

REAR WALL GRAB BAR

FOR WATER CLOSET

PAPER TOWEL

DISPENSER

6"

12" MAX 42" MIN

54" MIN

16"-18"

24" MIN 12"MIN

36" MIN

" M

IN

" M

AX

TOILET PAPER

DISPENSER LOCATION

(RECESSED)

O

PE

R

AT

IN

G H

T

" M

AX

T

O

COAT HOOK

M

AX

1"

" M

IN

39" - 41"

" M

AX

M

AX

1'

5"

24" MIN

36" MAX

CL

42' MAX

" M

IN

TOILET PAPER

DISPENSER LOCATION

(PROTRUDING BELOW

GRAB BAR)

24" MIN

42 " MAX

" M

AX

TOILET PAPER

DISPENSER LOCATION

(PROTRUDING ABOVE

GRAB BAR)

24" MIN

36" MAX

1/

2" M

IN

" M

IN

2'

0"

SE

AT

H T

9"

NOTE: MOUNTING HEIGHTS MAY VARY DEPENDING ON REACH RANGE

CONDITION. FIXTURES AND ACCESSORIES SHOWN ARE FOR GRAPHIC

PURPOSES ONLY, REFER TO SPECS FOR ACTUAL PROJECT MODEL

NUMBERS.

URINAL

TRANSFER-TYPE SHOWER

CONTROL

AREA

" M

IN

3" -6

6"

BLOCKING

AREA

CL

CONTROL WALL

" M

IN

" M

AX

15"MAX

(GB)

4"MAX

BLOCKING

AREA

BACK WALL

"-1

9"

1' - 6"

6"

15"-16"

22"-23"

CL

3'

0"

CARD

READER

1'

0"

FEC A

1'

0"

FEC B

w/ FLANGE

" M

AX

" M

IN

DIAPER

CHANGING

TABLE

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

P R

O J E

C T

N O

Autodesk Docs://West Point Bldg 606/219208-WP606-A20.rvt

10/10/2025 11:48:28 AM

A-002

G E

N E

R A

L L

E G

E N

D S

A N

D N

O T

E S

U N

IT

E

D S

T A

T E

S M

IL

IT

A R

Y A

C A

D E

M Y

W

E S

T P

O

IN

T

N Y

P N

F

Y

N E

W Y

O R

K D

IS

T

R

IC

T N

E W

Y O

R K

N

Y

S M

S

S M

S

M P

K

V N

S

E P

T E

M B

E R

W

D

S

C

Q P

K J

O B

N O

.0

ADDENDUM #6

R E

P A

IR

B

L D

G

G E

N E

R A

L I N

S T

R U

C T

IO

N

B L

D G

DIMENSIONING LEGEND NOTES

DIM LEGEND NOTE

1 MASONRY PLAN DIMENSIONS AT SCALES NOT SHOWING INDIVIDUAL MODULES ARE TO NOMINAL FACE OF MASONRY

2 NON MASONRY DIMENSIONS ARE TO FINISHED FACE OF THE PARTITION ASSEMBLY UNLESS NOTED OTHERWISE

3 MASONRY ON DRAWINGS SHOWN WITH INDIVIDUAL MODULAR UNITS ARE DRAWN AT SCALE TO ACTUTAL SIZE, AND WHERE SHOWN INCLUDE MODULAR DIMENSION REFERENCE LINES.

4 MASONRY COURSING LINES IN ELEVATON REPRESENT NOMINAL DIMENSIONS. VERTICAL JOINTS ARE DIMENSIONED TO CENTERLINE OF JOINT. HORIZONTAL JOINTS ARE DIMENSIONED TO TOP OF MASONRY IN ELEVATION AND IN SECTION.

5 DIMENSIONS ARE FROM STRUCTURAL COLUMN CENTERLINES, UNO.

6 AT INTERSECTION OF DIFFERENT PARTITION TYPES, CONTINUE PARTITION OF GREATER FIRE RATING OR, IF NO FIRE RATING, GREATER ACOUSTICAL STC VALUE THROUGH INTERSECTION UNO.

7 REFER TO PARTITION SCHEDULE FOR PARTITION THICKNESS AND HEIGHT.

8 NON-ARCHITECTURAL DISCIPLINE INFORMATION IF SHOWN IS FOR REFERENCE ONLY. OBJECTS AND INFORMATION SHOWN MAY NOT BE ALL INCLUSIVE. REFER TO APPROPRIATE DISCIPLINE FOR INFORMATION.

9 REFER TO WORKPOINTS WHERE SHOWN FOR ELEMENTS PLACED ON NON-PARALLEL OR NON-PARALLEL RELATIONSHIPS. WORKPOINTS MAY ALSO BE SHOWN AS LAYOUT STARTING POINTS IN ORDER TO MAINTAIN CORRECT RELATIONSHIPS BETWEEN

ELEMENTS.

GENERAL DIMENSIONS, PARTITIONS TYPES AND OTHER SPECIFIC INFORMATION IN THE GUIDE DRAWINGS ARE EXAMPLES FOR ILLUSTRATIVE PURPOSES AND DO NOT REPRESENT ACTUAL INFORMATION FOR CONSTRUCTION OF A PARTICULAR PROJECT.

GENERAL NOTES - ARCHITECTURE

GENERAL NOTES

1 SEE STRUCTURAL DRAWINGS FOR WIND, SNOW, SEISMIC AND OTHER STRUCTURAL LOAD INFORMATION

2 SEE "LIFE SAFETY PLANS" FOR REGULATORY INFORMATION AND UL ASSEMBLY DESIGNATIONS FOR FIRE RATED STEEL

STRUCTURE AND FLOOR ASSEMBLIES.

3 BUILDING DIRECTORY SIGNAGE AT ELEVATOR SHOWN FOR LOCATION PURPOSES ONLY. SIGNAGE PROVIDED AND INSTALLED BY

OTHERS. PROVIDE BLOCKING, POWER, AND DATA.

4 COORDINATE ALL WORK WITH STRUCTURAL, MEP/FP, TELECOMMUNICATIONS AND CIVIL WORK.

5 ALL PENETRATION IN RATED ASSEMBLIES MUST BE SEALED WITH UL/FM APPROVED MATERIAL ASSEMBLIES AND PROCEDURES.

6 MATHEMATICS 1st, THE WEST POINT MILITARY, AND SYSTEMS ENGINEERING SIGNAGE SHOWN ON CORRIDOR ELEVATIONS SHOWN FOR LOCATION PURPOSES ONLY. SIGNAGE PROVIDED AND INSTALLED BY OTHERS. PROVIDE PLYWOOD BLOCKING BACKER.

SCALE: NO SCALE

D6

DIMENSIONING GUIDE PLAN

SCALE: NO SCALE

D9

DIMENSIONING GUIDE EL / SECTION

SCALE: NO SCALE

F9

DIMENSIONING GUIDE EL / SECTION

SCALE: 1/4" = 1'-0"A1

TYPICAL ACCESSORY MOUNTING HEIGHTS

SCALE: NO SCALE

G6

GENERAL NOTES - ARCHITECTURE

SCALE: NO SCALE

C6

DIMENSIONING LEGEND NOTES

SCHEDULE-MISC ACCESSORIES & EQUIP

TAG

PREFIX MARK ITEM MANUFACTURER AND CODE NO. TYPE REMARKS

2 1A FIRE EXTINGUISHER CABINETS (FEC-A) JL INDUSTRIES - ACADEMY SERIES - FULLY

RECESSED, FLANGELESS

MOUNT B/O 1'-0" AFF

2 1B FIRE EXTINGUISHER CABINETS (FEC-B) SEMI RECESSED - SQUARE TRIM MOUNT B/O 1'-0" AFF

2 2 FIRE EXTINGUISHER FIRE EXTINGUISHER ON BRACKET MOUNT TOP OF HANDLE AT 4'-0" AFF

2 3 COAT HOOK - 2 PRONG CAMDEN-BOONE #121-004 HEAVY DUTY ALUM SILVER, UPPER HOOK (72" AFF)

/ LOWER HOOK (40" AFF); SEE PLAN

FOR EXTENT / COUNT

2 5 5'-0"H 6'-0"L CHALK BOARD PROVIDE FULL LENGTH OF WALL SURFACE

2 6 5'-0"H 6'-0"L WHITE BOARDS PROVIDE FULL LENGTH OF WALL SURFACE SEE ELEVATIONS FOR DIMENSIONS

2 7 5'-0"H CHALK BOARDS - LENGTH VARIES PROVIDE FULL LENGTH OF WALL SURFACE SEE ELEVATIONS FOR DIMENSIONS

2 8 5'-0"H WHITE BOARDS - LENGTH VAIRES PROVIDE FULL LENGTH OF WALL SURFACE SEE ELEVATIONS FOR DIMENSIONS

2 9 WHITE BOARDS - HEIGHT & LENGTH VAIRES PROVIDE FULL LENGTH OF WALL SURFACE SEE ELEVATIONS FOR DIMENSIONS

SCALE: NO SCALE

C3

SCHEDULE-MISC ACCESSORIES & EQUIP

NOTE: PROVIDE IN-WALL BLOCKING FOR ALL WALL MOUNTED ACCESSORIES AND EQUIPMENT.

A

D D

E N

D U

M

/1

/2

Sheets
A-002 - GENERAL LEGENDS AND NOTES

File details come from the government source that posted it. Updated .