This document is an architectural drawing sheet (A-002) from the US Army Corps of Engineers for a repair project at Building 606 at United States Military Academy, West Point, NY. The sheet contains detailed dimensioning legends, general architectural notes, and a comprehensive schedule of miscellaneous accessories and equipment mounting heights. Key details include specifications for fire extinguisher cabinets from JL Industries, coat hooks from Camden-Boone, and mounting height guidelines for various fixtures like chalk boards, white boards, toilet paper dispensers, and accessibility features. The project is part of contract W912DS19C0034, with an issue date of 2 September 2025 and an addendum (#6) dated 10 October 2025, indicating an ongoing design refinement process. The drawing provides precise technical guidance for installation of building elements, with specific attention to accessibility standards and mounting requirements.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1' A B
FOR DOOR OPENING
INFORMATION SEE
DOOR SCHEDULE
2"
7' - 4" 4' - 8"1
3'
0"1' - 8 1/4" 5 3/4"
FINISHED FACE OF
NON-MASONRY
WALL
NOMINAL FACE OF
MASONRY WALL
3 B
6 A
6 A
1 A
C8
A-002
1'
6"
1'
4" 8"
EL SECTION
8" 1'
4"
2'
0"
TOP OF MASONRY
UNIT BEYOND
ACTUAL FACE
OF MASONRYF
R O
M E
LE
V
A T
IO
N
B
SE
E
P
LA
N
3/ 8"
2"
33 ACTUAL FACE
OF MASONRY
NOMINAL DIMENSION
FROM PLAN
1/2" JT WIDTH
FACE OF
FINISHED
SURFACE
FROM PLAN
NOMINAL DIM
FROM PLAN
NOMINAL
MASONRY OPNG
1'
6"
SOAP
DISH
MIRROR
ACC-MOUNTHT-TUB-SHOWER ANSI 2009
(R
EC
O M
M
3'
6"
2'
6" M
IN
2'
CL
EXCEPTION:
24" GRAB BAR IS PERMITTED DUE
TO A RECESSED FIXTURE
ADJACENT TO WATER CLOSET.
SANITARY
NAPKIN
DISPOSAL
SIDE WALL GRAB BAR
FOR WATER CLOSET
REAR WALL GRAB BAR
FOR WATER CLOSET
PAPER TOWEL
DISPENSER
6"
12" MAX 42" MIN
54" MIN
16"-18"
24" MIN 12"MIN
36" MIN
" M
IN
" M
AX
TOILET PAPER
DISPENSER LOCATION
(RECESSED)
O
PE
R
AT
IN
G H
T
" M
AX
T
O
COAT HOOK
M
AX
1"
" M
IN
39" - 41"
" M
AX
M
AX
1'
5"
24" MIN
36" MAX
CL
42' MAX
" M
IN
TOILET PAPER
DISPENSER LOCATION
(PROTRUDING BELOW
GRAB BAR)
24" MIN
42 " MAX
" M
AX
TOILET PAPER
DISPENSER LOCATION
(PROTRUDING ABOVE
GRAB BAR)
24" MIN
36" MAX
1/
2" M
IN
" M
IN
2'
0"
SE
AT
H T
9"
NOTE: MOUNTING HEIGHTS MAY VARY DEPENDING ON REACH RANGE
CONDITION. FIXTURES AND ACCESSORIES SHOWN ARE FOR GRAPHIC
PURPOSES ONLY, REFER TO SPECS FOR ACTUAL PROJECT MODEL
NUMBERS.
URINAL
TRANSFER-TYPE SHOWER
CONTROL
AREA
" M
IN
3" -6
6"
BLOCKING
AREA
CL
CONTROL WALL
" M
IN
" M
AX
15"MAX
(GB)
4"MAX
BLOCKING
AREA
BACK WALL
"-1
9"
1' - 6"
6"
15"-16"
22"-23"
CL
3'
0"
CARD
READER
1'
0"
FEC A
1'
0"
FEC B
w/ FLANGE
" M
AX
" M
IN
DIAPER
CHANGING
TABLE
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
P R
O J E
C T
N O
Autodesk Docs://West Point Bldg 606/219208-WP606-A20.rvt
10/10/2025 11:48:28 AM
A-002
G E
N E
R A
L L
E G
E N
D S
A N
D N
O T
E S
U N
IT
E
D S
T A
T E
S M
IL
IT
A R
Y A
C A
D E
M Y
W
E S
T P
O
IN
T
N Y
P N
F
Y
N E
W Y
O R
K D
IS
T
R
IC
T N
E W
Y O
R K
N
Y
S M
S
S M
S
M P
K
V N
S
E P
T E
M B
E R
W
D
S
C
Q P
K J
O B
N O
.0
ADDENDUM #6
R E
P A
IR
B
L D
G
G E
N E
R A
L I N
S T
R U
C T
IO
N
B L
D G
DIMENSIONING LEGEND NOTES
DIM LEGEND NOTE
1 MASONRY PLAN DIMENSIONS AT SCALES NOT SHOWING INDIVIDUAL MODULES ARE TO NOMINAL FACE OF MASONRY
2 NON MASONRY DIMENSIONS ARE TO FINISHED FACE OF THE PARTITION ASSEMBLY UNLESS NOTED OTHERWISE
3 MASONRY ON DRAWINGS SHOWN WITH INDIVIDUAL MODULAR UNITS ARE DRAWN AT SCALE TO ACTUTAL SIZE, AND WHERE SHOWN INCLUDE MODULAR DIMENSION REFERENCE LINES.
4 MASONRY COURSING LINES IN ELEVATON REPRESENT NOMINAL DIMENSIONS. VERTICAL JOINTS ARE DIMENSIONED TO CENTERLINE OF JOINT. HORIZONTAL JOINTS ARE DIMENSIONED TO TOP OF MASONRY IN ELEVATION AND IN SECTION.
5 DIMENSIONS ARE FROM STRUCTURAL COLUMN CENTERLINES, UNO.
6 AT INTERSECTION OF DIFFERENT PARTITION TYPES, CONTINUE PARTITION OF GREATER FIRE RATING OR, IF NO FIRE RATING, GREATER ACOUSTICAL STC VALUE THROUGH INTERSECTION UNO.
7 REFER TO PARTITION SCHEDULE FOR PARTITION THICKNESS AND HEIGHT.
8 NON-ARCHITECTURAL DISCIPLINE INFORMATION IF SHOWN IS FOR REFERENCE ONLY. OBJECTS AND INFORMATION SHOWN MAY NOT BE ALL INCLUSIVE. REFER TO APPROPRIATE DISCIPLINE FOR INFORMATION.
9 REFER TO WORKPOINTS WHERE SHOWN FOR ELEMENTS PLACED ON NON-PARALLEL OR NON-PARALLEL RELATIONSHIPS. WORKPOINTS MAY ALSO BE SHOWN AS LAYOUT STARTING POINTS IN ORDER TO MAINTAIN CORRECT RELATIONSHIPS BETWEEN
ELEMENTS.
GENERAL DIMENSIONS, PARTITIONS TYPES AND OTHER SPECIFIC INFORMATION IN THE GUIDE DRAWINGS ARE EXAMPLES FOR ILLUSTRATIVE PURPOSES AND DO NOT REPRESENT ACTUAL INFORMATION FOR CONSTRUCTION OF A PARTICULAR PROJECT.
GENERAL NOTES - ARCHITECTURE
GENERAL NOTES
1 SEE STRUCTURAL DRAWINGS FOR WIND, SNOW, SEISMIC AND OTHER STRUCTURAL LOAD INFORMATION
2 SEE "LIFE SAFETY PLANS" FOR REGULATORY INFORMATION AND UL ASSEMBLY DESIGNATIONS FOR FIRE RATED STEEL
STRUCTURE AND FLOOR ASSEMBLIES.
3 BUILDING DIRECTORY SIGNAGE AT ELEVATOR SHOWN FOR LOCATION PURPOSES ONLY. SIGNAGE PROVIDED AND INSTALLED BY
OTHERS. PROVIDE BLOCKING, POWER, AND DATA.
4 COORDINATE ALL WORK WITH STRUCTURAL, MEP/FP, TELECOMMUNICATIONS AND CIVIL WORK.
5 ALL PENETRATION IN RATED ASSEMBLIES MUST BE SEALED WITH UL/FM APPROVED MATERIAL ASSEMBLIES AND PROCEDURES.
6 MATHEMATICS 1st, THE WEST POINT MILITARY, AND SYSTEMS ENGINEERING SIGNAGE SHOWN ON CORRIDOR ELEVATIONS SHOWN FOR LOCATION PURPOSES ONLY. SIGNAGE PROVIDED AND INSTALLED BY OTHERS. PROVIDE PLYWOOD BLOCKING BACKER.
SCALE: NO SCALE
D6
DIMENSIONING GUIDE PLAN
SCALE: NO SCALE
D9
DIMENSIONING GUIDE EL / SECTION
SCALE: NO SCALE
F9
DIMENSIONING GUIDE EL / SECTION
SCALE: 1/4" = 1'-0"A1
TYPICAL ACCESSORY MOUNTING HEIGHTS
SCALE: NO SCALE
G6
GENERAL NOTES - ARCHITECTURE
SCALE: NO SCALE
C6
DIMENSIONING LEGEND NOTES
SCHEDULE-MISC ACCESSORIES & EQUIP
TAG
PREFIX MARK ITEM MANUFACTURER AND CODE NO. TYPE REMARKS
2 1A FIRE EXTINGUISHER CABINETS (FEC-A) JL INDUSTRIES - ACADEMY SERIES - FULLY
RECESSED, FLANGELESS
MOUNT B/O 1'-0" AFF
2 1B FIRE EXTINGUISHER CABINETS (FEC-B) SEMI RECESSED - SQUARE TRIM MOUNT B/O 1'-0" AFF
2 2 FIRE EXTINGUISHER FIRE EXTINGUISHER ON BRACKET MOUNT TOP OF HANDLE AT 4'-0" AFF
2 3 COAT HOOK - 2 PRONG CAMDEN-BOONE #121-004 HEAVY DUTY ALUM SILVER, UPPER HOOK (72" AFF)
/ LOWER HOOK (40" AFF); SEE PLAN
FOR EXTENT / COUNT
2 5 5'-0"H 6'-0"L CHALK BOARD PROVIDE FULL LENGTH OF WALL SURFACE
2 6 5'-0"H 6'-0"L WHITE BOARDS PROVIDE FULL LENGTH OF WALL SURFACE SEE ELEVATIONS FOR DIMENSIONS
2 7 5'-0"H CHALK BOARDS - LENGTH VARIES PROVIDE FULL LENGTH OF WALL SURFACE SEE ELEVATIONS FOR DIMENSIONS
2 8 5'-0"H WHITE BOARDS - LENGTH VAIRES PROVIDE FULL LENGTH OF WALL SURFACE SEE ELEVATIONS FOR DIMENSIONS
2 9 WHITE BOARDS - HEIGHT & LENGTH VAIRES PROVIDE FULL LENGTH OF WALL SURFACE SEE ELEVATIONS FOR DIMENSIONS
SCALE: NO SCALE
C3
SCHEDULE-MISC ACCESSORIES & EQUIP
NOTE: PROVIDE IN-WALL BLOCKING FOR ALL WALL MOUNTED ACCESSORIES AND EQUIPMENT.