About this file

This document is a detailed architectural drawing (Sheet A-564) for a renovation project at the United States Military Academy, West Point, NY. The project involves repairing Building 606, specifically the General Instruction Building, under contract number W912DS19C0034QPK for the US Army Corps of Engineers. The drawing provides technical details for interior modifications, including section views and plan details for partition demolition, underlayment installation, and various structural elements. Key technical specifications include floor leveling requirements with different materials (epoxy fill mortar or cementitious leveling) depending on potential bid option awards, removal and infill of existing walls, and specific construction sequencing instructions. The document is dated 2 September 2025 and includes two addendums, with the most recent being Addendum #4 on 9/23/2025.

View the file

Other files

File Type Posted
Solicitation Amendment W912DS25RA0020009 SF 30.pdf PDF
Solicitation Amendment W912DS25RA0020008 SF 30.pdf PDF
E-512_AM 7.pdf PDF
I-108_AM 6.pdf PDF
I-105_AM 6.pdf PDF
I-100.3_AM 6.pdf PDF
I-100.2_AM 6.pdf PDF
AD-101_AM 6.pdf PDF
A-304_AM 6.pdf PDF
A-315_AM 6.pdf PDF
A-503_AM 6.pdf PDF
A-003_AM 6.pdf PDF
A-002_AM 6.pdf PDF
H-103_AM 6.pdf PDF
H-104_AM 6.pdf PDF
H-102_AM 6.pdf PDF
H-001_AM 6.pdf PDF
H-108_AM 6.pdf PDF
MP-102_AM 6.pdf PDF
MH-104_AM 6.pdf PDF
M-505_AM 6.pdf PDF
S-316_AM 6.pdf PDF
S-311_AM 6.pdf PDF
S-310_AM 6.pdf PDF
S-113_AM 6.pdf PDF
S-110_AM 6.pdf PDF
S-109_AM 6.pdf PDF
S-001_AM 6.pdf PDF
Submittal Register_AM 6.pdf PDF
Appendix G_AM 5.pdf PDF
A-602_AM 4.pdf PDF
M-303_AM3.pdf PDF
E-512 - DETAILS - ELECTRICAL_AM3.pdf PDF
MSEC- Building 606 - Amendment 3 - RFIs - 16 Sep 25.pdf PDF
Solicitation Amendment W912DS25RA0020003 SF 30.pdf PDF
HP802 - HVAC_PLUMBING_AND ELECTRICAL COORDINATION SCHEDULE_AM3.pdf PDF
E-618 - Panelboard Schedules_AM3.pdf PDF
A-319.pdf PDF
C-101.pdf PDF
RFIs_MSEC_Amendment 2 _ 2 Sep 25.pdf PDF
Criteria and Factors for Evaluation_Basis of Award_Evaluation Criteria_Rating System_AM 2 revised.pdf PDF
Solicitation Amendment W912DS25RA0020001 SF 30.pdf PDF
JA-007-25 Monaco Fire Alarm MSEC - 31 Jan 25 signedJF sDL_Redacted.pdf PDF
JA-002-25 Lutron Lighting Controls MSEC - 31 Jan 25 signedJF sDL rev. 1 -_Redacted.pdf PDF
JA-009-25 Semco Pinnacle DOAS MSEC - 31 Jan 25 signedJF sDL rev. 1_Redacted.pdf PDF
JA-005-25 DAS MSEC - 31 Jan 25 signedJF sDL -_Redacted.pdf PDF
JA-003-25 Shark Meter MSEC - 31 Jan 25 signedJF sDL -_Redacted.pdf PDF
Criteria and Factors for Evaluation_Basis of Award_Evaluation Criteria_Rating System.pdf PDF
W912DS19C0034 PN 94078 Repair Building 606 Revised RTA Drawings - Volume 2.pdf PDF
W912DS19C0034 PN 94078 Repair Building 606 Revised RTA Drawings - Volume 1.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A1

AC

A1.1

SINTERED STONE PANEL

(QTZ-501)

1 A

9 A

3 A

3 A

3 A

3 A

3 A

3 A

EXST WALL.

EXST WALL.

EXST WALL.

STEEL COL; REFER TO

STRUCT DWGS.

PROVIDE REQD

FIREPROOFING (TYP).

STOR

113AHC TLT

CORR

METAL CORNER TRIM,

SCHLUTER FINEC

ELEV LOBBY

1'

1/

4" 1'

1/ 4"

7"

1' - 5" 1' - 7"

1' - 7 3/4" 1' - 2"

1/

8" 1'

/2

1 A

A-559

E3

CERAMIC TILING

CORNER BEAD, TYP.

EXST CONC

ENCASED COLUMN

CERAMIC TILING

2 A

2' - 3 1/8"

A1.9 A2

AC

9 A 4 A

4 A

1 C

11 A

CORNER BEAD, TYP.

CONT 20GA MET

BACKING TO ATTACH

GWB.

EXST COLUMN W/ EXST

SPRAY FIREPROOFING.

1/

2"

1/ 8"

3 1/8" 5 1/2"

CORRIDOR

CLASSROOM

ELECT

EXISTING TOPPING SLAB.

EXISTING CINDER FILL.

EXISTING STRUCTURAL SLAB.

FILL VOID W/ 4000 PSI PEA

GRAVEL CONC TO TOP OF

LOWER SLAB.

REMOVE EXST WALL TO

TOP OF STRUCT SLAB.

TOSL-3W FLR (183'-6")

24' - 3"

C2

7'-0" A.F.F.

CLG.

CLG.

2 HR RATED

PER

STRUCT.

SST, ALL

SIDES

2'-4 5/8"

PILASTER

BEYOND

8"

EXIST.

5"

1' - 7 3/4"

9"

WOOD OR STONE

FINISH

STONE BASE

1'

0"

CHROME COVER

CORRIDOR

EXISTING SLAB

NEW CORIDOR/CLASSROOM

PARTION INSTALLED AFTER.

EPOXY FILL MORTAR LEVELING

IF MOE #1 IS AWARDED,

CEMENTITIOS LEVELING IF

MOE #1 IS NOT AWARDED.

TYP. CORRIDORTYP. CLASSROOM OR OFFICE

1. ALL FLOOR LEVELING UNDERLAYMENTS MUST BE INSTALLED PRIOR TO

THE INSTALLATION OF WALL FRAMING AND DOOR FRAMES.

CEMENTITIOUS LEVELING

MATERIAL.

2. EPOXY FILL MORTAR LEVELING MATERIALS ARE REQUIRED UNDER RESINOUS MATRIX

TERRAZZO FLOORING, IF MOE #1 IS AWARDED. CONSTRUCTION SEQUENCING MUST

ALLOW FOR THE POTENTIAL AWARD OF BID OPTIONS, AND DIFFERING UNDERLAYMENT

REQUIREMENTS.

REFER TO A1/A-564 FOR INFILL

AT ALL PARTITION WALL DEMO.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

P R

O J E

C T

N O

Autodesk Docs://West Point Bldg 606/219208-WP606-A20.rvt

9/23/2025 4:16:13 PM

A-564

D E

T A

IL

S

IN

T E

R

IO

R

U N

IT

E

D S

T A

T E

S M

IL

IT

A R

Y A

C A

D E

M Y

W

E S

T P

O

IN

T

N Y

P N

F

Y

N E

W Y

O R

K D

IS

T

R

IC

T N

E W

Y O

R K

N

Y

E P

C B

M P

K

V N

S

E P

T E

M B

E R

W

D

S

C

Q P

K J

O B

N O

.0

ADDENDUM #4

R E

P A

IR

B

L D

G

G E

N E

R A

L I N

S T

R U

C T

IO

N

B L

D G

SCALE: 1 1/2" = 1'-0"A6

PLAN DETAIL

SCALE: 1 1/2" = 1'-0"E8

PLAN DETAIL

SCALE: 1 1/2" = 1'-0"C1

NOT USED

SCALE: 1 1/2" = 1'-0"A1

TYP. SECTION - INFILL AT ALL PARTITION DEMO

SCALE: 1 1/2" = 1'-0"E1

SECTION - 2 HR HEAD

SCALE: 1 1/2" = 1'-0"E6

1 HR RATED PILASTER

A

D D

E N

D U

M

/2

/2

A

D D

E N

D U

M

/2

/2

SCALE: 1 1/2" = 1'-0"E4

SECTION @ CLEANOUT

SCALE: 1 1/2" = 1'-0"1

SECTION - TYP. UNDERLAYMENT DETAIL

Sheets
A-564 - DETAILS - INTERIOR

File details come from the government source that posted it. Updated .