About this file

This document is a Room Finish Schedule for the third floor of Building 606 at the United States Military Academy, West Point, NY. The project is part of a repair and renovation effort under contract number W912DS19C0034 for the US Army Corps of Engineers, New York District, with an issue date of 2 September 2025. The schedule details finishes for 53 rooms, including corridors, administrative spaces, classrooms, conference rooms, restrooms, and support areas, specifying floor, base, wall, and ceiling materials, finishes, and colors. Key finish materials include concrete floors, luxury vinyl tile (LVT), carpet, ceramic tile, gypsum wall board (GWB) with paint, and wood panels, with color codes ranging from 601-910. The document includes detailed tile pattern layouts, notes on tile installation, and references to additional finish schedules and interior elevations for specific room details.

View the file

Other files

File Type Posted
MSEC- Building 606 - Amendment 9 - RFIs - 5 Nov 25.pdf PDF
A-601_AM 9.pdf PDF
08 71 00_AM 9.pdf PDF
MP-101_AM 7.pdf PDF
E-611_AM 7.pdf PDF
08 71 00_AM 7.pdf PDF
MSEC- Building 606 - Amendment 7 - RFIs - 21 Oct 25.pdf PDF
I-130_AM 6.pdf PDF
I-100.1_AM 6.pdf PDF
AD-301_AM 6.pdf PDF
A-305_AM 6.pdf PDF
A-102_AM 6.pdf PDF
A-413_AM 6.pdf PDF
A-502_AM 6.pdf PDF
A-504_AM 6.pdf PDF
MP-107_AM 6.pdf PDF
MP-105_AM 6.pdf PDF
MP-101_AM 6.pdf PDF
MH-101_AM 6.pdf PDF
S-322_AM 6.pdf PDF
S-315_AM 6.pdf PDF
S-107_AM 6.pdf PDF
07 52 00_AM 6.pdf PDF
08 60 45_AM 6.pdf PDF
08 81 00_AM 6.pdf PDF
I-108_AM 6.pdf PDF
A-551_AM 5.pdf PDF
MSEC- Building 606 - Amendment 5 - RFIs - 8 Oct 25 rev JF.pdf PDF
Appendix G_AM 5.pdf PDF
A-601_AM 4.pdf PDF
Solicitation Amendment W912DS25RA0020004 SF 30.pdf PDF
A-602_AM 4.pdf PDF
A-564_AM 4.pdf PDF
MS-100_AM3.pdf PDF
01 91 19_AM3.pdf PDF
01 30 00_AM3.pdf PDF
M-303_AM3.pdf PDF
E-512 - DETAILS - ELECTRICAL_AM3.pdf PDF
MSEC- Building 606 - Amendment 3 - RFIs - 16 Sep 25.pdf PDF
Solicitation Amendment W912DS25RA0020003 SF 30.pdf PDF
E-513.pdf PDF
A-121.pdf PDF
07 60 00.pdf PDF
A-319.pdf PDF
MSEC- Building 606 - Amendment 1 - RFIs - 20 Aug 25.pdf PDF
Solicitation Amendment W912DS25RA0020001 SF 30.pdf PDF
W912DS19C0034 PN 94078 Repair Building 606 Revised RTA Drawings - Volume 4.pdf PDF
W912DS19C0034 PN 94078 Repair building 606 REV.RTA Specification Manual Volume 3.pdf PDF
W912DS19C0034 PN 94078 Repair building 606 REV.RTA Specification Manual Volume 1.pdf PDF
JA-007-25 Monaco Fire Alarm MSEC - 31 Jan 25 signedJF sDL_Redacted.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1'

0"

TILE 204

(12x48)

TILE 205

(24x48)

TILE - 401

2' - 0"

TILE - 203

(12x24)

TYPICAL TOILET ROOM TILE PATTERN

1'

4"2'

0"

8"

1' - 0"

4'

0"

1'

4" 4'

0"

4'

0"

1' - 0" 2' - 0" 1' - 0" 1' - 0" 2' - 0" 2' - 0"

2'

8"

1'

4"

2'

8" 4'

0"

4'

0" 4'

0"

TYPICAL STAIRS 1& 2 TILE PATTERN

TILE 204

(12x48)

TILE 205

(24x48)

TILE NOTES:

TILE LAYOUT SHALL AVOID UNBALANCED THIN CUTS AND

AVOID SLIVERS AT CORNERS WHEREVER POSSIBLE

TILE BASE IN RESTROOMS, ALIGN GROUT JOINT WITH CENTER

ALL OUTER CORNERS AND EXPOSED TILE EDGES TO BE

CAPPED ACCORDING TO TRIM DETAILS. SEE C1/A-559

EQ EQ

6" 6"

SOUND ATTENUATING

INSULATION, AS

SCHEDULED.

PARTITION- SEE PLAN

FOR PARTITION TYPES.

EPOXY, AS

SCHEDULED.

6"

FRP-701 AND ALL

ASSOCIATED TRIM PIECES.

3/ 4"

EPOXY, AS

SCHEDULED.

FRP-701 AND ALL

ASSOCIATED TRIM

PIECES.

6"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

P R

O J E

C T

N O

Autodesk Docs://West Point Bldg 606/219208-WP606-A20.rvt

10/13/2025 12:19:51 PM

I-100.3

B A

S E

B

ID

R

D

F L

R R

O O

M F

IN

IS

H S

C H

E D

U L

E

U N

IT

E

D S

T A

T E

S M

IL

IT

A R

Y A

C A

D E

M Y

W

E S

T P

O

IN

T

N Y

P N

F

Y

N E

W Y

O R

K D

IS

T

R

IC

T N

E W

Y O

R K

N

Y

E P

E K

K

L

M P

K

V N

S

E P

T E

M B

E R

W

D

S

C

Q P

K J

O B

N O

.0

ADDENDUM #6

R E

P A

IR

B

L D

G

G E

N E

R A

L I N

S T

R U

C T

IO

N

B L

D G

SCHEDULE-ROOM FINISH 3RD FLR

ROOM

NUMBER ROOM NAME

FLOOR BASE WALL CEILING

COMMENTS ROOM NUMBER MATERIAL FINISH COLOR MATERIAL COLOR MATERIAL FINISH COLOR MATERIAL FINISH COLOR

301 HISTORIC CORRIDOR CONC LVT 307, 308 EXST -- EXST WD PNL / EXST 803 EXST -- SEE MOE FINISH SCHEDULE FOR UPGRADED FINISHES. 301

302 DEPT RECEPT CONC LVT 307, 308 RB 403 GWB PNT 901 APC / GWB -- / PNT 606 / 901 SEE MOE FINISH SCHEDULE FOR UPGRADED FINISHES. 302

303 HALLWAY CONC LVT 307, 308 RB 403 GWB PNT 901 APC / GWB -- / PNT 604 / 901 SEE MOE FINISH SCHEDULE FOR UPGRADED FINISHES. 303

304 DEPT HEAD CONC CPT 103 RB 402 GWB PNT 901, 905 APC 601 304

305 SM CONF CONC CPT 103 RB 403 GWB PNT / AWP 901, 905 / 702 APC 601 305

306 ADMIN CONC CPT 103 RB 402 GWB PNT 901, 905 APC 601 306

307 PROF CONC CPT 103 RB 402 GWB PNT 901, 905 APC 601 307

308 COLLAB CONC CPT 103 RB 403 GWB PNT 901, 905 APC 601 308

309 BREAK RM CONC LVT 307 RB 402 GWB PNT 901 APC -- 601 SEE MOE FINISH SCHEDULE FOR UPGRADED FINISHES. 309

310 CORRIDOR CONC LVT 308 RB 403 GWB EPOXY PNT 901 APC / GWB -- / PNT 604 / 901 SEE MOE FINISH SCHEDULE FOR UPGRADED FINISHES. 310

311 ADMIN CONC CPT 103 RB 402 GWB PNT 901, 905 APC 601 311

312 ADMIN CONC CPT 103 RB 402 GWB PNT 901, 905 APC 601 312

313 ADMIN CONC CPT 103 RB 402 GWB PNT 901, 905 APC 601 313

314 ADMIN CONC CPT 103 RB 402 GWB PNT 901, 905 APC 601 314

315 ADMIN CONC CPT 103 RB 402 GWB PNT 901, 905 APC 601 315

316 STORAGE CONC SEALER 910 RB 402 GWB PNT 901 EXPOSED 901 316

317 COLLAB CONC CPT 103 RB 403 GWB PNT 901 APC 601 317

318 COLLAB CONC CPT 103 RB 403 GWB PNT 901 APC 601 318

319 COLLAB CONC LVT 307, 308 RB / GLASS / EXST 403 / - / - GWB / GLASS / EXST QTZ / -- / -- 802 / -- / -- APC / GWB -- / PNT 608 / 901 SEE MOE FINISH SCHEDULE FOR UPGRADED FINISHES. 319

320 HC TLT CONC TILE 201 TILE 401 GWB TILE 203 APC 602 320

321 HC TLT CONC TILE 201 TILE 401 GWB TILE 203 APC 602 321

322 ELECT CONC SEALER 910 RB 402 GWB PNT 901 EXPOSED 901 322

323 HALL CONC LVT 307, 308 RB 403 GWB PNT 901 APC / GWB -- / PNT 607 / 901 SEE MOE FINISH SCHEDULE FOR UPGRADED FINISHES. 323

324 SM CONF CONC CPT 103 RB 403 GWB PNT / AWP 901, 905 / 702 APC 601 324

325 CLASSROOM CONC LVT 303, 305 RB 403 GWB PNT 901, 905 APC 601 325

326 CLASSROOM CONC LVT 303, 305 RB 403 GWB PNT 901, 905 APC 601 326

327 COLLAB CONC LVT 307, 308 RB 403 GWB PNT 901 APC / GWB -- / PNT 607 / 901 SEE MOE FINISH SCHEDULE FOR UPGRADED FINISHES. 327

328 ELEV LOBBY CONC LVT 307, 308 RB 403 GWB / GLASS / EXST PNT / QTZ 901 / 801, 802 APC / GWB -- / PNT 608 / 901 SEE MOE FINISH SCHEDULE FOR UPGRADED FINISHES. 328

329 CORRIDOR CONC LVT 307, 308 RB 403 GWB QTZ / EPOXY PNT 802 / 901 APC / GWB -- / PNT 606 / 901 SEE MOE FINISH SCHEDULE FOR UPGRADED FINISHES. 329

330 WOMENS CONC TILE 201 TILE 401 GWB TILE 203, 201 APC / GWB -- / PNT 602 / 901 SEE INTERIOR ELEVATIONS AND FINISH PLANS FOR ACCENT WALL LOCATION. 330

331 JAN CONC EPOXY 351 EPOXY 404 GWB FRP/PNT 701/901 APC -- 602 331

332 MENS CONC TILE 201 TILE 401 GWB TILE 203, 201 APC / GWB -- / PNT 602 / 901 SEE INTERIOR ELEVATIONS AND FINISH PLANS FOR ACCENT WALL LOCATION. 332

333 CLASSROOM CONC LVT 303, 305 RB 403 GWB PNT 901, 905 APC 601 333

334 CLASSROOM CONC LVT 303, 305 RB 403 GWB PNT 901, 905 APC 601 334

335 CLASSROOM CONC LVT 303, 305 RB 403 GWB PNT 901, 905 APC 601 335

336 SM CONF CONC CPT 103 RB 403 GWB PNT / AWP 901, 905 / 702 APC 601 336

337 HALLWAY CONC LVT 307 RB 403 GWB PNT 901 APC -- 601 SEE MOE FINISH SCHEDULE FOR UPGRADED FINISHES. 337

338 BREAK RM CONC LVT 307 RB 403 GWB PNT 901 APC -- 601 SEE MOE FINISH SCHEDULE FOR UPGRADED FINISHES. 338

339 CONF CONC CPT 106 RB 403 GWB PNT / AWP 901, 905 / 702 APC 601 339

340 COPY CONC LVT 308 RB 403 GWB PNT 901 APC -- 601 SEE MOE FINISH SCHEDULE FOR UPGRADED FINISHES. 340

341 INSTRUCTOR CONC CPT 103 RB 402 GWB PNT 901 APC 601 341

342 INSTRUCTOR CONC CPT 103 RB 402 GWB PNT 901 APC 601 342

343 INSTRUCTOR CONC CPT 103 RB 402 GWB PNT 901 APC 601 343

344 HALL CONC LVT 307, 308 RB 403 GWB PNT 901 APC -- 601 SEE MOE FINISH SCHEDULE FOR UPGRADED FINISHES. 344

345 STORAGE CONC LVT 307 RB 402 GWB PNT 901 EXPOSED PNT 901 345

346 INSTRUCTOR CONC CPT 103 RB 402 GWB PNT 901 APC 601 346

347 INSTRUCTOR CONC CPT 103 RB 402 GWB PNT 901 APC 601 347

348 ELECT CONC SEALER 910 RB 402 GWB PNT 901 EXPOSED 901 348

349 IT CONC RESIL 302 RB 402 GWB PNT 901 EXPOSED 901 349

350 CLASSROOM CONC LVT 303, 305 RB 403 GWB PNT 901, 905 APC 601 350

351 CLASSROOM CONC LVT 303, 305 RB 403 GWB PNT 901, 905 APC 601 351

352 CLASSROOM CONC LVT 303, 305 RB 403 GWB PNT 901, 905 APC 601 352

353 MATHEMATICS LAB CONC / RAF CPT 105 RB 403 WD/GWB PNT 803 / 901 APC 603 353

NOTE:

SEE INTERIOR ELEVATIONS AND FINISH PLANS FOR FINISH EXTENTS.

SCALE: 1/2" = 1'-0"A6

TYP TILE PATTERNS

SCALE: 3" = 1'-0"A1

SECTION - FRP PANELS

A

D D

E N

D U

M

/1

/2

File details come from the government source that posted it. Updated .