PROJECT IDENTIFICATION SIGN
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
The graphic format for this 4' x 6' sign panel follows the legend guidelines and layout as specified below. The large 4' x 4' section of the panel in the right is to be white with black legend. The 2' x 4' section of the sign on the left with the full corps Signature (reverse version) is to be screen printed Communications Red on the white background. The castle insignia will be furnished by the Government in pressure sensitive vinyl for affixing by the Contractor.
See attached sheet for fabrication and mounting guidelines.
SAMPLE:
2"
Supervised by Design and Construction
Architect: Contractor:
Picatinny Arsenal
Color: White Typeface: 1.25" Helvetica Regular
Legend Group 3: One- to
PROJECT IDENTIFICATION SIGN
MILITARY PROJECT
4.5"
6.25"
Ballistic Evaluation Center description of Corps relationship to project
Legend Group 1: One- to two-line 3"
Castle)
Color: White
District Name (optional). Place below 10.5" Reverse Signature (6"
Typeface: 1.25" Helvetica Regular Maximum line length: 19"
Legend Group 2: Division or three-line project title legend describes the work being done under this contract.
Color: Black Typeface: 3" Helvetica Bold Maximum line length: 42"
Legend Group 4: One-to two-line line identification of prime identification of project or facility (civil works) or name of sponsoring department (military).
Color: Black
Legend Group 5a-b: One-to-five
Typeface: 1.5" Helvetica Regular Maximum line length: 42" initial capitals only as shown.
Letter and word spacing to follow Corps standards as specified in
Typeface: 1.25" Helvetica Regular Maximum line length: 21"
All typography is flush left and rag right upper and lower case with
(Dimensions are in inches)
(architect, general contractor, etc.), corporate or firm name, city, state.
Use of Legend Group 5 is optional.
contractors including: type
Cross-align the first of Legend Group 4 with the first line of the Corps Signature (US Army Corps) as shown.
7.75"
9.5"
2"
1.875"
New Jersey
21" 3" 42" 3"
1.875"
1.875"
4.5"
6"
2.25"
6"
4.5"
48"
3" 21" 1" 21"
Mounting
Jacobs
Type Legend
Sign
Arlington, VA
Color Size Size Code Height Bkg/Lgd Panel
1.875"
WH-RD/BK
00800 - 37
* Refers to the U.S. Army Corps of Engineers, "Sign Standards Manual", EPS-310-1-6.
CID-01 various 4' x 6'
* Appendix D
Color: Black
4' x 4' HDO-3
10.5" of Engineers New York District
US Army Corps
2.5"
Post Specification
As Construction Project Identification signs Detailed specifications for and Safety Performance signs are to be HDD plywood panel preparation are pro-fabricated and installed as described vided in Appendix B.** below. The signs are to be erected at a Shown below the mounting diagram is location designated by the contracting of- a panel layout grid with spaces provided ficer and shall conform to the size, format, for project information. Photocopy this and typographic standards shown on page and use as a worksheet when pre-the attached sheets. paring sign legend orders.
The sign panels are to be fabri-cated from .75" High Density Over-lay Plywood. Panel preparation to follow HDD specifications provided in Appendix B. **
Sign graphics to be prepared on a white non-reflective vinyl film with positionable adhesive backing.
All graphics except for the Com-munications Red background with Corps signature on the project sign are to be die-cut or computer-cut non-reflective vinyl, pre-spaced legends prepared in the sizes and typefaces specified and applied to the background panel following the graphic formats shown on the attached sheets.
The 2'x4' Communications Red panel (to match PMS-032) with full Corps signature (reverse ver-sion) is to be screen printed on the white background. Identifica-tion of the District or Division may be applied under the signature with white cut vinyl letters pre-pared to Corps standards. Large Construction Project Sign scale reproduction artwork for the Legend Group 1: Corps Relationship signature is provided on page 4.8
Drill and Insert six (6) .375" T-nuts from the front face of the HDD Legend Group 2: Division/District Name
Apply graphic panel to prepared Legend Group 3: Project Title HDD plywood panel following better. Post to be 12" long. Drill six (6) .375" mounting holes in Legend Group 4: Facility Name uprights to align with T-nuts in sign
Assemble sign panel and uprights. Legend Group 5a: Contractor/A&E Legend Group 5b: Contractor /A&E Imbed assembled sign panel and
Safety Performance Sign Legend Group 1: Project Title
Legend Group 2: Contractor/A&E
00800 - 38
1.
2.
5. 5.
1.
2.
reinforce installation as shown 3. 3.
4. 4.
require bolting additional 2"x4" 2. 2.
struts on inside face of uprights to uprights in 4" hole. Local soil con- 1. 1.
ditions and/or wind loading may panel. Countersink (.5") back of 1.
hole to accept socket head cap screw (4"x.375"). 2.
2.Sign uprights to be structural grade 4"x4" treated Douglas Fir
3.or Southern Yellow Pine. No.1 or with sign face. 2.
manufacturers' instructions. 1.
2.
sign panel. Position holes as 1.
shown. Flange of T-nut to be flush
18"
(photographically enlarge from 1.
6.875" to 10.5"). **
Fabrication and Mounting Guidelines
48"
48"
(Dimensions in inches)
** Refers to the U.S. Army Corps of Engineers, "Sign Standards Manual", EP-310-1-6.
The graphic format, color, size and type-faces used on the sign are to be reproduced exactly as specified below. The title with First Aid logo in the top section of the sign, and the performance record captions are standard for all signs of this type. Legend Group 2 and 3 below identify the project and the contractor and are to be placed on the sign as shown.
Safety record numbers are mounted on individual metal plates and are screw-mounted to the background to allow for daily revisions to posted safety performance record.
Legend Group1: Standard two-line title "safety is a Job Requirement", with (8" od.) Safety Green First Aid logo. Color: To match PMS 347 Typeface: 3" Helvetica Bold Color: Black
Legend Group 2: One- to two-line project title legend describes the work being done under this contract and name of host project. Ballistic Evaluation Center Color: Black 2.25" Picatinny Arsenal, NJ Typeface: 1.5" Helvetica Regular Maximum line length: 42"
2.25" Legend Group 3: One - to two-line identification: name of prime This project has Days without & contractor and city, state address. 1.875" operated: lost time injury 4.875" Color: Black Typeface: 1.5" Helvetica Regular Total days worked Maximum line length: 42" 1.875" on this contract 4.875"
Legend Group 4: Standard safety Lost time record captions as shown. 1.875" injuries 4.875" Color: Black
Typeface: 1.25" Helvetica Regular
Replaceable numbers are to be mounted on white .060: aluminum plates and screw-mounted to background.
Color: Black Typeface: 3" Helvetica Regular Plate size: 2.5"x.5"
All typography is flush left and rag right, upper and lower case with initial capitals only as shown.
Letter- and word-spacing to follow Corps standards as specified in Appendix D. *
* Refer to the U.S. Army Corps of Engineers, "Sign Standards Manual", EPS-310-1-6.
Sign Legend Post Specifications Mounting Color Type Size Size Code Height Bkg/Lgd CID-02 various HDO-3 48" WH/BK-GR
00800 - 39
.875"
3.125"
.975"
2.5"
4"x4" 4"x4"
2.5" 2.5"
See attached sheet for fabrication and mounting guidelines.
Panel Size
10.5"
3" 31"
Dimensions inches.
3" 2" 17"
6"
3.875"
4.5"
3"
4"
3"
3"
SAFETY PERFORMANCE SIGN
Safety is a Job Requirement
3" 3"8"