Use Me IDC DLC HF IDC DLC 22R0049 Fire Protection Plumbing Mechanical Electrical Drawings Part 3 of 3.pdf
PDF 28 MB Posted
- Solicitation number
- W912DR22R0049
About this file
This document outlines a federal contract opportunity for construction services. The U.S. Army Corps of Engineers, Baltimore District, is soliciting proposals for a firm-fixed price design-bid-build construction contract to build a two-story, 32,000 square foot Instructional Design Center and Distance Learning Center facility at Harpers Ferry, West Virginia. Requirements include construction of offices, open work areas, a green screen room, sound editing booth, collaboration rooms, conference rooms, and parking area. The project scope encompasses installation of utilities, stormwater management, an elevator, HVAC system, electrical system, LED lighting, fire suppression system, finishes, paving, and landscaping. The magnitude of construction is estimated between $10-25 million with a 550 calendar day performance period from notice to proceed. Proposals are due on October 3, 2022 and will be evaluated using lowest price technically acceptable criteria.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FAAP
FMCU
NAC
LOC
SPD
CM
MM
F
P
ID
C
S
C
S
V
F S
S T
F
C F
DOC
FOT
FIRE ALARM LEGEND
SYMBOL DESCRIPTION
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
DOCUMENT CABINET
FIBER OPTIC TRANSCEIVER
NOTIFICATION APPLIANCE CIRCUIT PANEL
LOCAL OPERATOR CONTROL
SURGE PROTECTION DEVICE
CONTROL MODULE
MONITOR MODULE
MANUAL PULL STATION
SMOKE DETECTOR / SENSOR
SMOKE DETECTOR / PHOTOELECTRIC
SMOKE DETECTOR / IN DUCT
CO
CARBON MONOXIDE SENSOR
COMBINATION SPEAKER / VISIBLE WALL MOUNTED.
CD INDICATES CANDELA RATING.
COMBINATION SPEAKER / VISIBLE CEILING MOUNTED.
CD INDICATES CANDELA RATING.
CD
CD
SPEAKER WALL MOUNTED.
SPEAKER CEILING MOUNTED.
BELL - VIBRATING
FLOW SWITCH
TAMPER SWITCH
FIRE ALARM WALL MOUNTED VISUAL ONLY STROBE.
CD INDICATES CANDELA RATING.
FIRE ALARM CEILING MOUNTED VISUAL ONLY STROBE.
CD INDICATES CANDELA RATING.
CD
CD
LED TEXT SIGNS
END OF LINE RESISTOREOLR
TEXT
WEATHERPROOF
ELEVATOR RECALL
WP
ER
1. PROVIDE A COMPLETE, ADDRESSABLE, FIRE ALARM AND MASS NOTIFICATION SYSTEM IN THE FACILITY. FIRE ALARM AND MASS NOTIFICATION SYSTEM MUST BE DESIGNED AND INSTALLED TO MEET THE REQUIREMENTS
OF NFPA 70, NFPA 72, AND NFPA 101.
2. IT IS THE INTENT OF THESE DOCUMENTS TO PROVIDE DESIGN, MATERIALS, AND EQUIPMENT FOR A TOTALLY FUNCTIONING AND OPERATING FIRE ALARM AND MASS NOTIFICATION SYSTEMS, INCLUDING THE PROPER
INTERFACING AND COORDINATION WITH OTHER BUILDING SYSTEMS.
3. THE GENERAL CHARACTER AND SCOPE OF THE WORK IS ILLUSTRATED IN THE SPECIFICATIONS AND THE DRAWINGS. THE SPECIFICATIONS AND DRAWINGS ARE DIVIDED INTO SEVERAL SECTIONS FOR CONVENIENCE ONLY AND THE CONTRACT DOCUMENTS MUST BE CONSIDERED AS A WHOLE. THE CONTRACTOR MUST BE RESPONSIBLE FOR THE COORDINATION OF ALL TRADES, SUBCONTRACTORS, AND VENDORS ENGAGED IN THIS
WORK.
4. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF FIRE ALARM AND MASS NOTIFICATION SYSTEM EQUIPMENT AND FIELD DEVICES. FINAL LOCATIONS, QUANTITIES, APPLIANCE RATINGS, ETC. MUST BE PROVIDED BY THE INSTALLING CONTRACTOR IN ACCORDANCE WITH THE APPLICABLE CODES, STANDARDS, AND CONTRACT
DOCUMENTS.
5. THE CONTRACTOR MUST OBTAIN REQUIRED PERMITS AND APPROVALS AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. THE CONTRACTOR MUST PAY FOR AND SECURE PERMITS AND FEES FOR FIRE
PROTECTION SYSTEMS WORK.
6. PROVIDE FINAL SYSTEM LAYOUT DRAWINGS INCLUDING BATTERY CALCULATIONS AND VOLTAGE DROP CALCULATIONS AND OBTAIN APPROVAL OF THE FIRE MARSHAL AND ALL AUTHORITIES HAVING JURISDICTION.
BATTERY CALCULATIONS MUST INCLUDE 20 PERCENT SAFETY MARGIN TO THE CALCULATED AMP-HOUR RATING PER NFPA 72. A BILL OF MATERIAL AND CONTACT ID POINT DESCRIPTION TABLE MUST BE INCLUDED IN
THE FIRE ALARM AS-BUILT DRAWINGS.
7. PROVIDE FIRE ALARM AND MASS NOTIFICATION SPEAKERS AND STROBES THROUGHOUT THE PROJECT AREAS.
PROVIDE ADDITIONAL NOTIFICATION APPLIANCE CIRCUIT (NAC) PANELS AS REQUIRED FOR THE ADDITIONAL
DEVICES EACH NAC LOADING MUST NOT EXCEED 75% OF ITS RATED OUTPUT.
8. PROVIDE DUCT SMOKE DETECTORS IN ALL RETURN DUCTS OF AIR HANDLING UNITS GREATER THAN 2,000 CFM .
PROVIDE RELAYS FOR SHUT DOWN OF ASSOCIATED AIR HANDLING UNITS.
9. PROVIDE MONITOR MODULES, TAMPER AND FLOW SWITCHES FOR THE SPRINKLER RISER AND CONTROL
VALVES.
10. WIRING FOR DEVICES MUST BE CLASS B. PROVIDE ALL FIRE ALARM CIRCUITS IN ELECTRICAL METALLIC
TUBING (EMT) OR INTERMEDIATE METAL CONDUIT (IMC).
11. ALL RACEWAYS MUST BE FACTORY PAINTED RED. FLEXIBLE METALLIC CONDUIT (FMC) SHALL NOT EXCEED 6 FEET AND MUST ONLY BE PERMITTED FOR CONNECTIONS TO JUNCTION BOXES TO FIELD DEVICES. PROVIDE A RACEWAY LISTED FOR THE INSTALLATION IN WET LOCATIONS, SUCH AS RIGID METALLIC CONDUIT (RMC) AND LIQUID TIGHT FLEXIBLE METAL CONDUIT (LFMC). WET LOCATIONS ARE CONSIDERED ANY LOCATION WITHIN A 5
FOOT RADIUS OF FIRE SUPPRESSION EQUIPMENT AS DEFINED BY NFPA 70.
12. DEVICES MUST BE FACTORY FINISHED WHITE.
13. PROVIDE RECHARGEABLE SEALED LEAD ACID TYPE BATTERIES TO OPERATE THE FIRE ALARM SYSTEM UNDER
SUPERVISORY CONDITIONS FOR 48 HOURS AND AUDIBLE AND ALARM DEVICES FOR AN ADDITIONAL 15 MINUTES OR 60 MINUTES FOR THE MASS NOTIFICATION SYSTEM IMMEDIATELY UPON LOSS OF POWER, WHICHEVER IS GREATER.
14. INSTALLING CONTRACTOR MUST COORDINATE WITH MECHANICAL, ELECTRICAL AND OTHER TRADES TO FACILITATE INSTALLATION THAT IS COORDINATED AND CONSISTENT WITH BUILDING DESIGN, USE AND INTENT.
15. COORDINATE FINAL SYSTEM TESTING WITH OTHER CONTRACTORS TO PROVIDE FULL SYSTEM OPERATION AT
TIME OF TESTING.
16. THE FIRE PROTECTION CONTRACTOR MUST BE RESPONSIBLE FOR SCHEDULING AND PERFORMING
INSPECTIONS AND TESTS AS REQUIRED BY THE CONTRACTING OFFICER.
17. FLOOR AND WALL CONDUIT PENETRATIONS MUST BE SLEEVED AND SEALED AS REQUIRED. PROVIDE FIRE STOPPING FOR PENETRATIONS FOR CONDUITS OR PIPING PASSING THROUGH FLOOR SLABS, FIRE RATED
WALLS, RATED PARTITIONS, RATED CORRIDOR WALLS, AND VERTICAL SERVICE SHAFTS.
18. PENETRATIONS OF THE BUILDING AIR BARRIER MUST BE SEALED TO MAINTAIN THE INTEGRITY OF THE AIR
BARRIER.
19. PROVIDE CONDUIT FILL CALCULATIONS TO ENSURE 40% FILL DOES NOT EXCEED THE LIMITS OF NFPA 70.
20. CONDUIT AND WIRING MUST BE CONCEALED ABOVE CEILINGS IN FINISHED AREAS AND AREAS WITH DROPPED
CEILINGS. CONDUIT AND WIRING INSTALLED ABOVE CEILINGS MUST NOT INTERFERE WITH THE REMOVAL OF THE CEILING TILES, AND HVAC UNIT AIR FILTERS. IN AREAS WITHOUT CEILING, CONDUIT AND WIRING MUST BE INSTALLED AS TIGHT AS POSSIBLE TO UNDERSIDE OF FLOOR SLAB, UNLESS OBSTRUCTIONS REQUIRE
OTHERWISE.
21. FIRE ALARM WIRING MUST NOT BE INSTALLED IN THE SAME CONDUITS OR JUNCTION BOXES AS LIGHTING, POWER OR OTHER WIRING.
22. RUN WIRING TO CONTROL PANELS IN THE VERTICAL OR HORIZONTAL PLANE, MAKE TURNS AT 90 DEGREE ANGLES, AND TIGHTLY BUNDLE, WRAP, AND IDENTIFY CONDUCTORS INDIVIDUALLY WITH PERMANENT
MARKINGS.
23. PULL CONDUCTORS SPLICE FREE. THE USE OF WIRE NUTS, CRIMPED CONNECTORS, OR TWISTING OF
CONDUCTORS IS PROHIBITED.
24. TERMINATIONS MUST BE AT A TERMINAL STRIP. DEVICES MUST HAVE SCREW TERMINALS.
25. ALL SIGNALING LINE CIRCUITS MUST BE MINIMUM 18 AWG. INITIATING DEVICE AND NOTIFICATION APPLIANCE
CIRCUITS MUST BE MINIMUM 16 AWG.
26. WALL ADDRESSABLE CONTROL MODULES AND ADDRESSABLE MONITOR MODULES MUST BE LOCATED WITHIN
10 FEET OF THE DEVICES BEING MONITORED. DUCT SMOKE DETECTORS MUST BE WITHIN 3 FEET OF
ADDRESSABLE RELAY.
27. CONTRACTOR MUST PROVIDE ADEQUATE AUDIBLE NOTIFICATION DEVICES TO MEET AUDIBILITY AND INTELLIGIBILITY REQUIREMENTS. THE MINIMUM REQUIRED COMMON INTELLIGIBILITY SCALE IS 0.8.
28. PROVIDE SPEAKERS MOUNTED ON THE EXTERIOR OF THE BUILDING IN ADDITION TO PROVIDE NOTIFICATION OF ANY AREAS COMMONLY USED BY BUILDING OCCUPANTS. AREAS INCLUDE COURTYARDS, COVERED BREAK AREAS, DESIGNATED SMOKING AREAS, AND SIDEWALKS LEADING FROM THE BUILDING'S EXIT DOORS TO A PUBLIC STREET OR FROM PARKING AREAS FOR A DISTANCE UP TO 16 FEET FROM THE BUILDING.
29. PROVIDE VISIBLE NOTIFICATION APPLIANCES IN COMMON AND PUBLIC SPACES AS REQUIRED BY THE IBC AND
NFPA 72 TO MEET VISIBLE SIGNALING INTENSITY REQUIREMENTS.
30. PROVIDE CLEAR STROBE MARKED "ALERT" FOR FIRE ALARM AND MASS NOTIFICATION SYSTEM NOTIFICATIONS.
31. COORDINATE DUCT SMOKE DETECTION WITH MECHANICAL DESIGN CONTRACTOR. DUCT SMOKE DETECTOR
REMOTE LAMPS AND TEST STATION MUST BE WALL MOUNTED, ACCESSIBLE, VISIBLE, AND PERMANENTLY LABELED. THE DUCT DETECTORS MUST RECEIVE THEIR POWER AND RESET FROM THE FIRE ALARM CONTROL
UNIT.
32. PROVIDE REMOTE TEST LAMPS FOR ANY INACCESSIBLE DEVICES.
33. PROVIDE SURGE PROTECTION FOR CIRCUITS THAT ENTER OR EXIT A BUILDING.
34. PROVIDE WEATHERPROOF DEVICES AS REQUIRED AND AS INDICATED.
35. DEVICES MOUNTED IN SUSPENDED CEILING MUST BE MOUNTED IN THE CENTER OF THE CEILING TILE.
36. PROVIDE A DOCUMENTATION CABINET ADJACENT TO FIRE ALARM CONTROL PANEL. CABINET MUST BE STEEL WITH LOCKING, HINGE MOUNTED DOOR PROMINENTLY LABELED "SYSTEM RECORD DOCUMENTS". CABINET MUST STORE LIFE SAFETY, FIRE ALARM, AND SPRINKLER AS-BUILT DRAWINGS AND NFPA 72 RECORD OF COMPLETION IN PAPER FORMAT. CD/DVD OF SITE-SPECIFIC SOFTWARE, FIRE ALARM AND SPRINKLER AS-BUILT DRAWINGS, NFPA 72 RECORD OF COMPLETION, AND OPERATIONS AND MAINTENANCE MANUALS MUST BE
STORED IN A CD JEWEL CASE.
37. PROVIDE A PARTS BOX ADJACENT TO THE FMCP. CABINET MUST BE STEEL, LOCKING, WITH HINGE-MOUNTED DOOR, KEYED THE SAME AS THE FMCP. CABINET MUST INCLUDE SPARE PARTS AS DEFINED IN THE PROJECT
SPECIFICATIONS, PLUS FOUR (4) FUSES FOR EACH FUSED CONDUIT.
38. BATTERY BOX MUST BE INSTALLED NO HIGHER THAN 12 INCHES ABOVE FINISHED FLOOR.
39. DUAL-ACTION, MANUAL FIRE PULL STATIONS MUST BE PROVIDED WITHIN 5 FEET OF EVERY EXIT OF THE
BUILDING. MANUAL PULL STATIONS MUST BE RESET WITH THE USE OF A KEY ONLY. USE OF A WRENCH, HEX KEY, ALLEN KEY, OR ALLEN WRENCH TO OPEN A MANUAL PULL STATION MUST NOT BE PERMITTED.
40. PROVIDE A LAMINATED BUILDING FLOOR PLAN (22 INCH X 34 INCH) MOUNTED AT THE MAIN ENTRANCE OF THE BUILDING, ADJACENT TO THE ANNUNCIATOR. THE DRAWING MUST INDICATE THE FMCP, LOC, REMOTE POWER SUPPLY PANELS, AND ALL INITIATING DEVICES. THE DRAWING MUST INCLUDE ROOM NUMBERS.
41. THE BUILDING FIRE ALARM / MASS NOTIFICATION SYSTEM SHALL BE COMPATIBLE WITH THE EXISTING SITE FIBER
OPTIC RECEIVING STATION.
42. PROVIDE AND ATTACH A LEGIBLE, TYPED LABEL ON ALL ADDRESSABLE DEVICES TO INDICATE ITS ADDRESS.
FOR ANY DEVICE LOCATED ABOVE A FALSE CEILING, CONTRACTOR MUST PROVIDE A LEGIBLE, TYPED LABEL
ATTACHED TO THE CEILING GRID THE DEVICE NOMENCLATURE AND ADDRESS.
43. FIRE ALARM COMPANY TO INSTALL THE OPERATING SYSTEM AND SOFTWARE PACKAGE THAT IS ASSOCIATED WITH THE INSTALLED FIRE ALARM SYSTEM MUST INCLUDE THE DATA SHEETS FOR THE FIRE ALARM CONTROL PANEL CIRCUIT CARDS AND DEVICES INSTALLED, AND INSTALLATION, PROGRAMMING, OPERATION, AND MAINTENANCE MANUALS ON EACH LAPTOP.
44. LOCAL OPERATORS CONSOLES SHALL BE PROVIDED SUCH THAT ALL OCCUPANTS CAN REACH THE
MICROPHONE WITHIN 200 FEET.
FIRE ALARM AND MASS NOTIFICATION GENERAL NOTES FIRE ALARM AND MASS NOTIFICATION GENERAL NOTES
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
M B
I( A
E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
324199
FA001
F
IR
E A
L A
R M
G
E N
E R
A L N
O T
E S
A
B B
R E
V
IA
T
IO
N S
S Y
M B
O L S
H A
R P
E R
S F
E R
R Y
W
E S
T V
IR
G
IN
IA
F O
R T
W O
R T
H D
IS
T
R
IC
T T
A Y
L O
R S
T C
T O
F C
R M
A
F O
R T
W O
R T
H T
X
-0
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
L
Y N
D O
N B
J O
H N
S O
N F
W Y
S
U
IT
E
D A
L L A
S T
X
D W
A L T
E R
D W
A L T
E R
J A
S O
N T
A C
K E
T T
O P
A R
K
IN
S O
N
A U
G U
S T
W D
R -2
-R
-0
W G
-1 -D
-0
O P
T
IO
N T
IT
L E
O P
T
IO
N F
IE
L D
R T
A S
U B
M
IS
S
IO
N
IN
S
T R
U C
T
IO
N A
L D
E S
IG
N
C E
N T
E R
D
IS
T
A N
C E
L E
A R
N
IN
G C
E N
T E
R
P N
TOP OF HOISTWAY YES YES
PIT AREA NO NO
ELEVATOR LOBBIES YES YES
ELEVATOR CONTROL ROOM YES YES
ROOM / AREA
PROVIDE SPRINKLER
PROVIDE SMOKE DETECTION
ELEVATOR REQUIREMENTS
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
M B
I( A
E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
324200
FA002
F
IR
E A
L A
R M
S
E Q
U E
N C
E O
F O
P E
R A
T
IO
N S
H A
R P
E R
S F
E R
R Y
W
E S
T V
IR
G
IN
IA
F O
R T
W O
R T
H D
IS
T
R
IC
T T
A Y
L O
R S
T C
T O
F C
R M
A
F O
R T
W O
R T
H T
X
-0
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
L
Y N
D O
N B
J O
H N
S O
N F
W Y
S
U
IT
E
D A
L L A
S T
X
D W
A L T
E R
D W
A L T
E R
J A
S O
N T
A C
K E
T T
O P
A R
K
IN
S O
N
A U
G U
S T
W D
R -2
-R
-0
W G
-1 -D
-0
O P
T
IO
N T
IT
L E
O P
T
IO
N F
IE
L D
R T
A S
U B
M
IS
S
IO
N
IN
S
T R
U C
T
IO
N A
L D
E S
IG
N
C E
N T
E R
D
IS
T
A N
C E
L E
A R
N
IN
G C
E N
T E
R
P N
IN-DUCT SMOKE DETECTOR 22 X X X
PRE-RECORDED MNS MESSAGE ACTIVATION 21 X X X X X X
LIVE MICROPHONE MNS ACTIVATION 20 X X X X X X
ACTIVATION OF MASS NOTIFICATION SYSTEM 19 X X X X X X
TAMPER SWITCH 18 X X
COMMON SUPERVISORY 17 X X
S U
P E
R V
IS
O
R Y
C O
N D
IT
IO
N
S ELEVATOR SHUNT TRIP BREAKER POWER SUPERVISION 16 X X
GROUND FAULT 15 X X
CIRCUIT DISCONNECT 14 X X
LOW BATTERY 13 X X
NAC SHORT 12 X X
OPEN CIRCUIT 11 X X
LOSS OF PRIMARY AC POWER 10 X X
FIELD WIRING OR SYSTEM COMPONENT FAULT 9 X X
T R
O U
B
LE
C O
N D
IT
IO
N S
COMMON TROUBLE 8 X X
ACTIVATION OF HOISTWAY/CONTROL ROOM WATERFLOW SWITCH 7 X X X X X X X X
ACTIVATION OF MAIN WATERFLOW SWITCH 6 X X X X X X X
HOISTWAY AND ELEVATOR MACHINE ROOM SMOKE DETECTOR 5 X X X X X X X
ELEVATOR LOBBY SMOKE DETECTION (SECOND FLOOR) 4 X X X X X X
ELEVATOR LOBBY SMOKE DETECTOR (FIRST FLOOR) 3 X X X X X X
ACTIVATION OF AREA SMOKE DETECTOR 2 X X X X X
A
LA
R M
C O
N D
IT
IO
N S
ACTIVATION OF A MANUAL FIRE ALARM PULL STATION 1 X X X X X
SYSTEM INPUTS A B C D E F G H I J K L M N O P Q R
A N
N U
N C
IA
T
E A
LA
R
M S
IG
N
A L
A T
C O
N T
R O
L P
A N
E L
A
N N
U N
C
IA
T O
R
A N
N U
N C
IA
T
E T
R O
U B
LE
S
IG
N
A L
A T
C O
N T
R O
L P
A N
E L
A
N N
U N
C
IA
T O
R
A N
N U
N C
IA
T
E S
U P
E R
V
IS
O R
Y S
IG
N
A L
A T
C O
N T
R O
L P
A N
E L
A
N N
U N
C
IA
T O
R
A C
T
IV
A T
E F
IR
E
A
LA
R M
/M A
S S
N O
T
IF
IC
A
T
IO
N V
IS
U
A L
A N
D A
U D
IB
LE
A P
P
LI
A N
C E
S
A C
T
IV
A T
E L
E D
T E
X T
S
IG
N S
E
V A
C U
A T
E
M E
S S
A G
E
A C
T
IV
A T
E L
E D
T E
X T
S
IG
N S
A
N N
O U
N C
E M
E N
T
M E
S S
A G
E
S E
N D
A
LA
R M
S
IG
N A
L T
O S
U P
E R
V
IS
IN
G
S T
A T
IO
N
S E
N D
T R
O U
B
LE
S
IG
N A
L T
O S
U P
E R
V
IS
IN
G
S T
A T
IO
N
S E
N D
S U
P E
R V
IS
O
R Y
S
IG
N A
L T
O S
U P
E R
V
IS
IN
G
S T
A T
IO
N
S H
U T
D O
W N
A S
S O
C
IA
T E
D A
IR
H
A N
D
LI
N G
U N
IT
S
A C
T
IV
A T
E W
A T
E R
F
LO
W A
LA
R
M E
LE
C
T R
IC
B
E
LL
D E
A C
T
IV
A T
E F
IR
E
A
LA
R M
A U
D
IB
LE
S
IG
N
A
LS
R E
T U
R N
E G
R E
S S
L
IG
H T
IN
G
T O
N O
R M
A L
LE
V
E
LS
S E
N D
S
IG
N A
L T
O F
A C
IL
IT
Y W
ID
E
M A
S S
N O
T
IF
IC
A
T
IO
N S
Y S
T E
M
R E
C A
LL
E
LE
V
A T
O R
T O
F
IR
S T
F
LO
O R
R E
C A
LL
E
LE
V
A T
O R
T O
A
LT
E R
N A
T E
F
LO
O R
A C
T
IV
A T
E E
LE
V
A T
O R
C A
B W
A R
N
IN
G L
IG
H
T
D
IS
C O
N N
E C
T P
O W
E R
T O
E
LE
V A
T O
R S
SYSTEM OUTPUTS
SCALE: NTS
FIRE ALARM / MASS NOTIFICATION SYSTEM SEQUENCE OF OPERATIONS
D12
F
F
F
F S S
T
LO
C
LO
C
F A
A P
C 75
C 15
C 15
C
S
C 75 C
S
C 15
C 15
C
S
S
WP
S W
P
S W
P
S W
P
S
WP
V
ID
CM
S T
MM
MM MM
F
S S T
MM MM
MM
S
S T
C 75
C 75 C 75
GENERAL SHEET NOTES
1. REFER TO SHEET FA001 FOR GENERAL NOTES AND
SYMBOLS.
1 1.1 2 3 3.2 4 5
D
C
B.9
B.5
B
A.8
A
A.1
AA
F A
F A
TEXT
T E
X T
T E
X T
TEXT
TEXT
4.8
LOBBY
L100
CLOSET
104B
CLASSROOM 1
104.2
CLASSROOM 2
104.1
CLOSET
104A
VESTIBULE
V101
CORRIDOR
C101
STAIR B
STB1
ELEV LOBBY
C100
MECH
VESTIBULE
V100
TELE / COM
ELEV
STAIR A
STA1
P, ER
WP
JAN
X 3
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
M B
I( A
E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
A B
KEY PLAN
324201
FA111
F
IR
E A
L A
R M
F
IR
S
T F
L O
O R
P L A
N
A R
E A
A
H A
R P
E R
S F
E R
R Y
W
E S
T V
IR
G
IN
IA
F O
R T
W O
R T
H D
IS
T
R
IC
T T
A Y
L O
R S
T C
T O
F C
R M
A
F O
R T
W O
R T
H T
X
-0
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
L
Y N
D O
N B
J O
H N
S O
N F
W Y
S
U
IT
E
D A
L L A
S T
X
D W
A L T
E R
D W
A L T
E R
J A
S O
N T
A C
K E
T T
O P
A R
K
IN
S O
N
A U
G U
S T
W D
R -2
-R
-0
W G
-1 -D
-0
O P
T
IO
N T
IT
L E
O P
T
IO
N F
IE
L D
R T
A S
U B
M
IS
S
IO
N
IN
S
T R
U C
T
IO
N A
L D
E S
IG
N
C E
N T
E R
D
IS
T
A N
C E
L E
A R
N
IN
G C
E N
T E
R
P N
SCALE: 1/8" = 1'-0"
FIRE ALARM - FIRST FLOOR PLAN - AREA A
B6
PLAN NORTH
0 4' 8' 16'
1/8"=1'-0SCALE:
KEYNOTES
1 PROVIDE DUCT SMOKE DETECTION IN THE RETURN
DUCTS OF AIR HANDLING UNIT. PROVIDE CONTROL
MODULES TO SHUT DOWN AIR HANDLING UNIT.
2 PROVIDE TAMPER SWITCH AND MONITOR MODULE AT
POST INDICATOR VALVE.
3 PROVIDE MONITOR MODULES FOR FLOW SWITCH AND
TAMPER SWITCH FOR FIRST FLOOR SPRINKLER RISER
ASSEMBLY.
4 PROVIDE MONITOR MODULES FOR FLOW SWITCH AND
TAMPER SWITCH FOR SECOND FLOOR SPRINKLER RISER
ASSEMBLY.
5 PROVIDE TAMPER SWITCHES AND MONITOR MODULES
FOR BACKFLOW PREVENTER AND TEST HEADER
CONTROL VALVE.
6 PROVIDE STROBE ONLY NOTIFICATION APPLIANCE TO
LIMIT FEEDBACK THROUGH LOC.
F F
F
F
FMCU
DOC
FOT
NAC
SPD
P
C 15 C 15 C 15 C 15
C 15 C 15 C 15 C 15
C 15 C 15
C 15
C 15
C
S
C 75
C 30
C
S
C 30
C 30
C
S
S
WP
S W
P
S W
P
S
WP
CM
C 75 C 75
GENERAL SHEET NOTES
1. REFER TO SHEET FA001 FOR GENERAL NOTES AND
SYMBOLS.
6 7 8 9 109.9
D
C
B.9
B.5
B
A.8
A
A.1
AA
F A
F A
TEXT
T E
X T
TEXT
TEXT
X 4
6.2
LOBBY
L100
CLASSROOM 3
CLOSET
106A
COLLABORATION
115 COLLABORATION
COLLABORATION
COLLABORATION/ CONF
VESTIBULE
V101
COLLABORATION/ CONF
COLLABORATION
COLLABORATION
COLLABORATION
STAIR C
STC1
ELEV LOBBY
C100
KITCHENETTE
MEN'S
G101
WOMEN'S
G100
VESTIBULE
V100
ELEC
CORRIDOR
C103
COPY
CORRIDOR
C102
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
M B
I( A
E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
A B
KEY PLAN
324202
FA112
F
IR
E A
L A
R M
F
IR
S
T F
L O
O R
P L A
N
A R
E A
B
H A
R P
E R
S F
E R
R Y
W
E S
T V
IR
G
IN
IA
F O
R T
W O
R T
H D
IS
T
R
IC
T T
A Y
L O
R S
T C
T O
F C
R M
A
F O
R T
W O
R T
H T
X
-0
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
L
Y N
D O
N B
J O
H N
S O
N F
W Y
S
U
IT
E
D A
L L A
S T
X
D W
A L T
E R
D W
A L T
E R
J A
S O
N T
A C
K E
T T
O P
A R
K
IN
S O
N
A U
G U
S T
W D
R -2
-R
-0
W G
-1 -D
-0
O P
T
IO
N T
IT
L E
O P
T
IO
N F
IE
L D
R T
A S
U B
M
IS
S
IO
N
IN
S
T R
U C
T
IO
N A
L D
E S
IG
N
C E
N T
E R
D
IS
T
A N
C E
L E
A R
N
IN
G C
E N
T E
R
P N
SCALE: 1/8" = 1'-0"
FIRE ALARM - FIRST FLOOR PLAN - AREA B
B7
PLAN NORTH
0 4' 8' 16'
1/8"=1'-0SCALE:
KEYNOTES
1 PROVIDE SEPARATE NAC PANELS PER FLOOR. FINAL
NUMBER OF NAC PANELS SHALL BE DETERMINED BY
FIRE ALARM CONTRACTOR BASED ON SHOP DRAWINGS
CALCULATIONS.
2 PROVIDE CONTROL MODULE TO ACTIVATE THE LIGHTING
CONTROL DEVICE(S) UPON ACTIVATION OF THE
BUILDING FIRE ALARM SYSTEM IN ACCORDANCE WITH
NFPA 101: 7.8.1.2.2.
C 15
C 15
C 15 C 30
C 15
C 15 C 15 C 15
C 30
C 30
C 75
C
S
C
S
C
S
C
S
C 30
C
S
C
S C
S
C
S
F S S
T
MM
ID
LOC
CM
C
S
S
S
1 1.1 2 3 3.2 4 5
D
C
B.9
B.5
B
A.8
A
A.1
AA
F A
F A
T E
X T
4.8
2 PERSON OFFICE
OFFICE
OFFICE
225 DESIGN ROOM 1
DESIGN ROOM 3
OPEN STAFF BAY
ELEV LOBBY
C200
TECH / COMMS
CORRIDOR
C203
LAN/SWITCH
DESIGN ROOM 2
CONFERENCE ROOM
STAIR B
STB1
TELE / COMM
OFFICE
COLLABORATION AREA
CORRIDOR
C202
STAIR A
STA1
CORRIDOR
C204
P, ER
JAN
MECHANICAL
ELEV
P, ER
GENERAL SHEET NOTES
1. REFER TO SHEET FA001 FOR GENERAL NOTES AND
SYMBOLS.
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
M B
I( A
E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
A B
KEY PLAN
324203
FA121
F
IR
E A
L A
R M
S
E C
O N
D F
L O
O R
P L A
N
A R
E A
A
H A
R P
E R
S F
E R
R Y
W
E S
T V
IR
G
IN
IA
F O
R T
W O
R T
H D
IS
T
R
IC
T T
A Y
L O
R S
T C
T O
F C
R M
A
F O
R T
W O
R T
H T
X
-0
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
L
Y N
D O
N B
J O
H N
S O
N F
W Y
S
U
IT
E
D A
L L A
S T
X
D W
A L T
E R
D W
A L T
E R
J A
S O
N T
A C
K E
T T
O P
A R
K
IN
S O
N
A U
G U
S T
W D
R -2
-R
-0
W G
-1 -D
-0
O P
T
IO
N T
IT
L E
O P
T
IO
N F
IE
L D
R T
A S
U B
M
IS
S
IO
N
IN
S
T R
U C
T
IO
N A
L D
E S
IG
N
C E
N T
E R
D
IS
T
A N
C E
L E
A R
N
IN
G C
E N
T E
R
P N
SCALE: 1/8" = 1'-0"
FIRE ALARM - SECOND FLOOR PLAN - AREA A
B7
PLAN NORTH
0 4' 8' 16'
1/8"=1'-0SCALE:
KEYNOTES
1 PROVIDE TAMPER SWITCH AND FLOW SWITCH
CONNECTIONS FOR ELEVATOR HOISTWAY SPRINKLER
CONTROL VALVE AND SHUNT. FLOW SWITCH SHALL NOT
BE CAPABLE OF TIME DELAY.
2 PROVIDE DUCT SMOKE DETECTION IN THE RETURN
DUCTS OF AIR HANDLING UNIT. PROVIDE CONTROL
MODULES TO SHUT DOWN AIR HANDLING UNIT.
3 PROVIDE STROBE ONLY NOTIFICATION APPLIANCE TO
LIMIT FEEDBACK THROUGH LOC.
0 2' 4' 8'
SCALE: 1/4"=1'-0
NAC
P
C 15
C 15 C 15 C 15
C 30
C 30
C 30
C
S
C
S
C 15
C 30
C 15
C 15
F S S
T
MM
C 15
S
S
C 15
MM
CM
P,ER
GENERAL SHEET NOTES
1. REFER TO SHEET FA001 FOR GENERAL NOTES AND
SYMBOLS.
2. FIRE ALARM / MASS NOTIFICATION SYSTEM
NOTIFICATION APPLIANCE PLACEMENT TO BE PROVIDED
AT DESIGN DEVELOPMENT.
6 7 8 9 109.9
D
C
B.9
B.5
B
A.8
A
A.1
AA
F A
F A
T E
X
TLOC
6.2
GREEN SCREEN / SOUND
STUDIO
OPEN STAFF BAY
ELEV LOBBY
C200
CORRIDOR
C205
LAN/SWITCH
DESIGN ROOM 5
2 PERSON OFFICE
OFFICE
DESIGN ROOM 4
DESIGN ROOM 6
STORAGE
205A
STAIR C
STC1
MEN'S
G201
WOMEN'S
G200
KITCHENETTE
ELEC
CORRIDOR
C206
COPY AREA
201.1
UNISEX TLT
G202
FA122
B2
MOTHER'S NURSING
CORRIDOR
C201
ELEV DISCONNECT
CLOSET
2 X 4
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
M B
I( A
E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
A B
KEY PLAN
324204
FA122
F
IR
E A
L A
R M
S
E C
O N
D F
L O
O R
P L A
N
A R
E A
B
H A
R P
E R
S F
E R
R Y
W
E S
T V
IR
G
IN
IA
F O
R T
W O
R T
H D
IS
T
R
IC
T T
A Y
L O
R S
T C
T O
F C
R M
A
F O
R T
W O
R T
H T
X
-0
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
L
Y N
D O
N B
J O
H N
S O
N F
W Y
S
U
IT
E
D A
L L A
S T
X
D W
A L T
E R
D W
A L T
E R
J A
S O
N T
A C
K E
T T
O P
A R
K
IN
S O
N
A U
G U
S T
W D
R -2
-R
-0
W G
-1 -D
-0
O P
T
IO
N T
IT
L E
O P
T
IO
N F
IE
L D
R T
A S
U B
M
IS
S
IO
N
IN
S
T R
U C
T
IO
N A
L D
E S
IG
N
C E
N T
E R
D
IS
T
A N
C E
L E
A R
N
IN
G C
E N
T E
R
P N
SCALE: 1/8" = 1'-0"
FIRE ALARM - SECOND FLOOR PLAN - AREA B
B7
PLAN NORTH
0 4' 8' 16'
1/8"=1'-0SCALE:
KEYNOTES
1 PROVIDE SEPARATE NAC PANELS PER FLOOR. FINAL
NUMBER OF NAC PANELS SHALL BE DETERMINED BY
FIRE ALARM CONTRACTOR BASED ON SHOP DRAWINGS
CALCULATIONS.
2 PROVIDE CONTROL MODULES FOR THE FOLLOWING
ELEVATOR FUNCTIONS: A) PRIMARY RECALL, B)
SECONDARY RECALL, C) FIRE FIGHTER'S HAT (STEADY),
D) FIRE FIGHTER'S (FLASHING).
3 PROVIDE STROBE ONLY NOTIFICATION APPLIANCE TO
LIMIT FEEDBACK THROUGH LOC.
4 PROVIDE MONITOR MODULE FOR THE FOLLOWING
ELEVATOR FUNCTION: ELEVATOR SHUNT TRIP BREAKER
POWER SUPERVISION.
5 PROVIDE FLOW AND TAMPER SWITCH CONNECTIONS
FOR ELEVATOR CONTROL ROOM ISOLATION VALVE.
FLOW SWITCH SHALL NOT BE CAPABLE OF TIME DELAY.
REF: FA122SCALE: 1/4" = 1'-0"
B2
FIRE ALARM - ENLARGED ELEVATOR
CONTROL ROOM
GENERAL SHEET NOTES
1. REFER TO SHEET FA001 FOR GENERAL NOTES AND
SYMBOLS.
TO EXIT DOOR
5' (MAX.)
TO HIGHEST PORTION
OF OPERABLE PART
48" MAX
42" MIN
MANUAL PULL
STATION
FINISHED
WALL
FINISHED
FLOOR
CEILING
FINISHED
FLOOR
72"
60"NOTE:
FIRE ALARM CONTROL UNIT:
RECESSED OR SEMI-RECESSED
IN FINISHED SPACES AND SURFACE
MOUNTED IN UNFINISHED SPACES
TOP OF CABINET 72" ABOVE
FINISHED FLOOR OR CENTER
OF CABINET AT 60" ABOVE
FINISHED FLOOR, WHICHEVER
IS LOWER.
NAC
PANEL
NOTIFICATION
APPLIANCE CIRCUIT
PANEL:
NO HIGHER THAN 60" TO
CENTER OF PANEL
60"
FMCU
FAAP
60"
LOC
48"
NO MORE THAN 48" TO TOP
MESSAGE BUTTON AND
MICROPHONE
AUDIO / VISUAL
DEVICE
ALERT
100 PERCENT SYNCHRONIZATION OF STROBES,
REGARDLESS OF NUMBER, LOCATION, OR SEPARATION.
STROBE ONLY
DEVICE
6" M
IN
IM
U M
M
IN
IM
U
M O
F
0" T
O B
O T
T O
M O
F L
E N
S
M A
X
IM
U M
O F
6"
T O
T O
P O
F L
E N
S
NOTE: REFER TO THE PROPER
DEVICE INSTALLATION
INSTRUCTIONS FOR BACKBOX
MOUNTING HEIGHT
CEILING
ALERT
M A
X
IM
U M
O F
6"
T O
T O
P O
F L
E N
S
M
IN
IM
U
M O
F
0" T
O B
O T
T O
M O
F L
E N
S
CEILING
12" (300 mm)
MAX
ACCEPTED HERE
WALL MOUNTED
SMOKE DETECTOR
FINISHED WALL
NOTE:
MEASUREMENTS SHOWN ARE TO
THE CLOSEST EDGE OF THE
DETECTOR
TOP OF DETECTOR
ACCEPTABLE HERE
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
M B
I( A
E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
324205
FA501
F
IR
E A
L A
R M
D
E T
A
IL
S
H A
R P
E R
S F
E R
R Y
W
E S
T V
IR
G
IN
IA
F O
R T
W O
R T
H D
IS
T
R
IC
T T
A Y
L O
R S
T C
T O
F C
R M
A
F O
R T
W O
R T
H T
X
-0
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
L
Y N
D O
N B
J O
H N
S O
N F
W Y
S
U
IT
E
D A
L L A
S T
X
D W
A L T
E R
D W
A L T
E R
J A
S O
N T
A C
K E
T T
O P
A R
K
IN
S O
N
A U
G U
S T
W D
R -2
-R
-0
W G
-1 -D
-0
O P
T
IO
N T
IT
L E
O P
T
IO
N F
IE
L D
R T
A S
U B
M
IS
S
IO
N
IN
S
T R
U C
T
IO
N A
L D
E S
IG
N
C E
N T
E R
D
IS
T
A N
C E
L E
A R
N
IN
G C
E N
T E
R
P N
SCALE: NTS
FIRE ALARM - MANUAL PULL STATION HEIGHTS
H2
SCALE: NTS
FIRE ALARM - FMCP, FAAP, LOC, AND NAC PANEL HEIGHTS
H9
SCALE: NTS
FIRE ALARM - AUDIO/VISUAL APPLIANCE INSTALLATION DETAIL
A2
SCALE: NTS
FIRE ALARM - SMOKE DETECTOR HEIGHTS
A9
1. REFER TO SHEET FA001 FOR GENERAL NOTES AND
SYMBOLS.
MM
F S
F P
(TYP)
SPDNAC
120 VAC
POWER
TYPICAL NOTIFICATION APPLIANCE CIRCUIT
SS
WPWP
FMCU
SPD
(TYP)
WET-PIPE
SPRINKLER SYSTEM
EOLR
MM
(TYP)
T S
FIBER OPTIC
TRANSCEIVER
P, ER
EOLR
SECOND FLOOR
FIRST FLOOR
SPDEOLR
EOLR
TYPICAL NOTIFICATION APPLIANCE CIRCUIT
NAC SPD
120 VAC
POWER
ID CM
RTL
SHUTDOWN ASSOCIATED
AIR HANDLING UNIT
CM CM CM CM MM
• ELEVATOR RECALL
(PRIMARY AND SECONDARY)
• ELEVATOR CAB WARNING LIGHT
(FLASHING AND STEADY)
• ELEVATOR SHUNT TRIP
• ELEVATOR SHUNT BREAK
POWER SUPERVISION
F
P, ER
LOC
FAAP
MM
F S
(TYP)
ELEVATOR
SPRINKLER SYSTEM
MM
(TYP)
T S
TEXTTEXT
TEXTTEXT
LOC
120 VAC POWER TO 20A
DEDICATED CIRCUIT
BREAKER
P
TYPICAL SPEAKER APPLIANCE CIRCUIT
EOLR
TYPICAL SPEAKER APPLIANCE CIRCUIT
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
M B
I( A
E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
324206
FA701
F
IR
E A
L A
R M
R
IS
E
R D
IA
G
R A
M
H A
R P
E R
S F
E R
R Y
W
E S
T V
IR
G
IN
IA
F O
R T
W O
R T
H D
IS
T
R
IC
T T
A Y
L O
R S
T C
T O
F C
R M
A
F O
R T
W O
R T
H T
X
-0
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
L
Y N
D O
N B
J O
H N
S O
N F
W Y
S
U
IT
E
D A
L L A
S T
X
D W
A L T
E R
D W
A L T
E R
J A
S O
N T
A C
K E
T T
O P
A R
K
IN
S O
N
A U
G U
S T
W D
R -2
-R
-0
W G
-1 -D
-0
O P
T
IO
N T
IT
L E
O P
T
IO
N F
IE
L D
R T
A S
U B
M
IS
S
IO
N
IN
S
T R
U C
T
IO
N A
L D
E S
IG
N
C E
N T
E R
D
IS
T
A N
C E
L E
A R
N
IN
G C
E N
T E
R
P N
SCALE: NTS
SCHEMATIC FIRE ALARM / MASS NOTIFICATION SYSTEM RISER DIAGRAM
B3
1. PROVIDE AN AUTOMATIC, SUPERVISED WET PIPE FIRE SPRINKLER SYSTEM THROUGHOUT THE FACILITY.
2. THE CONTRACTOR MUST PERFORM A FIRE HYDRANT FLOW TEST IN ACCORDANCE WITH NFPA 291.
SPRINKLER HYDRAULIC DESIGN MUST BE BASED ON NEW HYDRANT FLOW TESTS PERFORMED BY THE
CONTRACTOR.
3. THE FIRE PROTECTION SYSTEM MUST COMPLY WITH THE IBC, NFPA 13, AND WITH THESE CONTRACT
DRAWINGS.
4. FIRE PROTECTION MATERIALS MUST BE UL LISTED AND/OR FM APPROVED.
5. INSTALLING CONTRACTOR MUST OBTAIN APPROVAL OF THE FIRE MARSHAL AND AUTHORITIES HAVING
JURISDICTION.
6. IT IS THE INTENT OF THESE DOCUMENTS TO PROVIDE DESIGN, MATERIALS AND EQUIPMENT FOR A TOTALLY
FUNCTIONING AND OPERATING FIRE PROTECTION SYSTEM, INCLUDING THE PROPER INTERFACING AND
COORDINATING WITH ALL OTHER BUILDING SYSTEMS.
7. THE GENERAL CHARACTER AND SCOPE OF THE WORK IS ILLUSTRATED IN THE SPECIFICATIONS AND DRAWINGS. THE SPECIFICATIONS AND DRAWINGS ARE DIVIDED INTO SEVERAL SECTIONS FOR CONVENIENCE ONLY AND THE CONTRACT DOCUMENTS MUST BE CONSIDERED AS A WHOLE. THE CONTRACTOR MUST BE RESPONSIBLE FOR THE COORDINATION OF ALL TRADES, SUBCONTRACTORS, AND VENDORS ENGAGED IN
WORK.
8. THE SPRINKLER SYSTEM DESIGNER MUST BE RESPONSIBLE FOR AVOIDING CONFLICTS BETWEEN FIRE PROTECTION SYSTEMS AND LIGHTING FIXTURES, DIFFUSERS, GRILLES, DUCTS, EQUIPMENT FIXTURES, STRUCTURAL MEMBERS, PIPES, CONDUITS, AND OTHER OBSTRUCTIONS ENCOUNTERED.
9. PIPING LAYOUTS, WHERE SHOWN, ARE DIAGRAMMATIC AND SHOW SYSTEM INTENT. PIPING MAY REQUIRE ADDITIONAL OFFSETS, DROPS, AND RISERS. CONTRACTOR MUST BE RESPONSIBLE FOR FINAL PIPING LAYOUT
AND HYDRAULIC CALCULATIONS.
10. SPRINKLER PIPING MUST BE INSTALLED SO THAT ALL PORTIONS OF THE SYSTEM CAN BE DRAINED BACK THROUGH THE MAIN DRAIN VALVES. WHERE TRAPPED SECTIONS OF PIPING CANNOT BE AVOIDED, AUXILIARY
DRAINS MUST BE PROVIDED. PROVIDE TEST AND DRAIN CONNECTIONS IN ACCORDANCE WITH
SPECIFICATIONS AND NFPA 13.
11. THE INCOMING SPRINKLER SERVICE SHALL BE PROVIDED WITH A DOUBLE CHECK VALVE BACKFLOW PREVENTER. NEW BACKFLOW PREVENTER SHALL INCLUDE A FORWARD FLOW TEST CONNECTION, WITH ONE 2 1/2 INCH HOSE CONNECTION FOR EVERY 250 GPM OF ANTICIPATED FLOW OF THE SPRINKLER SYSTEM.
12. DRAINS MUST TERMINATE TO THE EXTERIOR OF THE BUILDING AND BE PROVIDED WITH A SPLASH BLOCK.
DRAINS MAY NOT TERMINATE AT JANITOR'S CLOSETS OR OTHER INTERNAL DRAINS.
13. LOCATE CONTROL VALVES, TEST VALVES, AND LOW POINT DRAIN VALVES IN READILY ACCESSIBLE AREAS WITHIN 6 FEET OF THE FLOOR. TEST VALVES MUST DISCHARGE TO THE OUTSIDE OF THE BUILDING ONTO A
SPLASH BLOCK IF NOT DISCHARGING TO A PAVED SURFACE.
14. HYDRAULIC CALCULATIONS MUST BE BASED ON AREA/DENSITY APPROACH ONLY. SPECIAL DESIGN
APPROACHES, SUCH AS ROOM DESIGN MUST NOT BE USED.
15. PROVIDE AT LEAST ONE HYDRAULIC CALCULATION FOR EACH HAZARD CLASSIFICATION. HYDRAULIC CALCULATIONS MUST INCLUDE A MINIMUM PRESSURE DROP ACROSS THE BACKFLOW PREVENTERS OF 8.0 PSI, OR THE ACTUAL PRESSURE DROP WHICHEVER IS GREATER, REGARDLESS OF TYPE OR SIZE.
16. THE SPRINKLER SYSTEMS MUST BE DESIGNED HYDRAULICALLY FOR UNIFORM DISCHARGE DENSITIES ON THE
FOLLOWING BASIS
17. MAXIMUM SPRINKLER PROTECTION AREA MUST BE 225 SQUARE FEET PER SPRINKLER FOR LIGHT HAZARD AREAS AND 130 SQUARE FEET PER SPRINKLER FOR ORDINARY HAZARD AREAS. EXTENDED COVERAGE
SPRINKLERS ARE NOT PERMITTED.
18. PROVIDE PROTECTIVE CAGES ON SPRINKLERS LOCATED LESS THAN 7 FEET ABOVE THE FINISHED FLOOR AND
IN AREAS SUBJECT TO MECHANICAL DAMAGE.
19. PROVIDE INTERMEDIATE AND HIGH TEMPERATURE HEADS AS NEEDED TO MEET NFPA 13, SECTION 8.3.2.5.
THIS INCLUDES BUT IS NOT LIMITED TO UNIT HEATERS, HEATING DUCTS AND DIFFUSERS.
20. CENTER SPRINKLERS IN CENTER OF CEILING TILE.
21. SPRINKLER CONTROL VALVES MUST BE ELECTRICALLY SUPERVISED UNLESS OTHERWISE NOTED.
22. GALVANIZED PIPING IS NOT PERMITTED TO BE USED IN DRY PIPE, PREACTION, OR WET PIPE SPRINKLER
SYSTEMS.
23. PIPING MUST BE INSTALLED TO MAINTAIN CEILING HEIGHTS OR CLEARANCES IN ACCORDANCE WITH NFPA 13, NFPA 101, AND THE CONTRACT DOCUMENTS.
24. PENETRATIONS OF THE BUILDING AIR BARRIER MUST BE SEALED TO MAINTAIN THE INTEGRITY OF THE AIR
BARRIER. REFER TO ARCHITECTURE DRAWINGS FOR LOCATION AND DETAILS OF AIR BARRIERS.
25. DAMAGE TO WALLS, PARTITIONS, CEILINGS AND FLOORS FROM PENETRATIONS, INSTALLATION OR OTHER
ACTIONS OF THE SPRINKLER INSTALLER MUST BE PATCHED, REPAIRED, PAINTED WITH NEW MATERIALS TO
ORIGINAL CONDITION.
26. STRUCTURAL MEMBERS MUST NOT BE CUT, DRILLED OR BURNED UNLESS PREVIOUSLY APPROVED BY THE
PROJECTS STRUCTURAL ENGINEER AND CONTRACTING OFFICER.
27. PROVIDE SPRINKLER PROTECTION UNDER OBSTRUCTIONS, INCLUDING DUCTS, THAT ARE GREATER THAN 4
FEET.
28. PAINT CONCEALED PIPING AND PIPING IN NORMALLY UNOCCUPIED SPACES WITH PRIMER AND TWO COATS OF
RED OIL BASED PAINT.
29. PAINT EXPOSED PIPING IN OCCUPIED SPACES WITH PRIMER AND TWO COATS OF OIL BASE MATCHING THE
CEILING PAINT IN THE SPACE.
30. PROVIDE SPRINKLER GAUGE INSTALLATION LABELS ON EACH SPRINKLER GAUGE SHOWING SPRINKLER
GAUGES HAVE BEEN TEST OR REPLACED WITHIN FIVE YEARS.
31. PROVIDE A WALL-MOUNTED, TWO-INLET SIAMESE FIRE DEPARTMENT CONNECTION ON THE EXTERIOR WALL
OF THE MECHANICAL ROOM.
FIRE PROTECTION GENERAL NOTESFIRE PROTECTION ABBREVIATIONS AND LEGEND
SYMBOL ABBREV DESCRIPTION
OH-1
LIGHT HAZARD
ORDINARY HAZARD, GROUP 1OH-1
LH
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
M B
I( A
E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
324207
FX001
F
IR
E P
R O
T E
C T
IO
N
G E
N E
R A
L N
O T
E S
A
B B
R E
V
IA
T
IO
N S
S Y
M B
O L S
H A
R P
E R
S F
E R
R Y
W
E S
T V
IR
G
IN
IA
F O
R T
W O
R T
H D
IS
T
R
IC
T T
A Y
L O
R S
T C
T O
F C
R M
A
F O
R T
W O
R T
H T
X
-0
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
L
Y N
D O
N B
J O
H N
S O
N F
W Y
S
U
IT
E
D A
L L A
S T
X
D W
A L T
E R
D W
A L T
E R
J A
S O
N T
A C
K E
T T
O P
A R
K
IN
S O
N
A U
G U
S T
W D
R -2
-R
-0
W G
-1 -D
-0
O P
T
IO
N T
IT
L E
O P
T
IO
N F
IE
L D
R T
A S
U B
M
IS
S
IO
N
IN
S
T R
U C
T
IO
N A
L D
E S
IG
N
C E
N T
E R
D
IS
T
A N
C E
L E
A R
N
IN
G C
E N
T E
R
P N
ORDINARY HAZARD, GROUP 1 0.15 / 1,500 8.0 130
LIGHT HAZARD 0.1 / 1,500 5.6 225
HAZARD CLASSIFICATION
DESIGN DENSITY/AREA
(GPM/SF/SF)
MINIMUM K-FACTOR MAXIMUM SPRINKLER COVERAGE (SF)
FLOW: 1,384 GPM
RESIDUAL PRESSURE: 35 PSI
STATIC PRESSURE: 87 PSI
TESTED BY: D. WALTER, PE (MICHAEL BAKER INTERNATIONAL)
TEST DATE: 19 MAY 2022
HYDRANT FLOW DATA
TOP OF HOISTWAY YES YES
PIT AREA NO NO
ELEVATOR LOBBIES YES YES
ELEVATOR CONTROL ROOM YES YES
ROOM / AREA
PROVIDE SPRINKLER
PROVIDE SMOKE DETECTION
ELEVATOR REQUIREMENTS
1 1.1 2 3 3.2 4 5
D
C
B.9
B.5
B
A.8
A
A.1
AA
OH-1
F X
F X
FX501
J1
4.8
LOBBY
L100
CLOSET
104B
CLASSROOM 1
104.2
CLASSROOM 2
104.1
CLOSET
104A
VESTIBULE
V101
CORRIDOR
C101
STAIR B
STB1
ELEV LOBBY
C100
MECH
VESTIBULE
V100
JAN
TELE / COM
ELEV
STAIR A
STA1
GENERAL SHEET NOTES
1. REFER TO SHEET FX001 FOR GENERAL NOTES AND
SYMBOLS
2. ALL AREAS ARE CLASSIFIED AS LIGHT HAZARD UNLESS
NOTED OTHERWISE.
3. FIRE SPRINKLER PIPING IS SHOWN FOR REFERENCE
ONLY AND IS INTENDED TO SHOW SYSTEM INTENT. IT IS
THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR
TO DETERMINE FINAL PIPING LAYOUT.
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
M B
I( A
E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
A B
KEY PLAN
324208
FX111
F
IR
E P
R O
T E
C T
IO
N
F
IR
S
T F
L O
O R
P L A
N
A R
E A
A
H A
R P
E R
S F
E R
R Y
W
E S
T V
IR
G
IN
IA
F O
R T
W O
R T
H D
IS
T
R
IC
T T
A Y
L O
R S
T C
T O
F C
R M
A
F O
R T
W O
R T
H T
X
-0
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
L
Y N
D O
N B
J O
H N
S O
N F
W Y
S
U
IT
E
D A
L L A
S T
X
D W
A L T
E R
D W
A L T
E R
J A
S O
N T
A C
K E
T T
O P
A R
K
IN
S O
N
A U
G U
S T
W D
R -2
-R
-0
W G
-1 -D
-0
O P
T
IO
N T
IT
L E
O P
T
IO
N F
IE
L D
R T
A S
U B
M
IS
S
IO
N
IN
S
T R
U C
T
IO
N A
L D
E S
IG
N
C E
N T
E R
D
IS
T
A N
C E
L E
A R
N
IN
G C
E N
T E
R
P N
SCALE: 1/8" = 1'-0"
FIRE PROTECTION - FIRST FLOOR PLAN - AREA A
B6
PLAN NORTH
0 4' 8' 16'
1/8"=1'-0SCALE:
KEYNOTES
1 PROVIDE SIDEWALL SPRINKLERS FOR PROTECTION OF
SHADED AREA.
2 PIPING SHALL BE INSTALLED A MINIMUM OF 12 INCHES
BELOW THE BOTTOM OF BUILDING FOUNDATIONS OR
FOOTERS IN ACCORDANCE WITH NFPA 24 SECTION
10.4.3.1.2. PIPE JOINTS SHALL NOT BE LOCATED
DIRECTLY UNDER FOUNDATION FOOTINGS.
6 7 8 9 109.9
C
B.9
B.5
B
A.8
A
A.1
AA
OH-1
F X
F X
6.2
LOBBY
L100
CLASSROOM 3
CLOSET
106A
COLLABORATION
115 COLLABORATION
COLLABORATION
COLLABORATION/ CONF
VESTIBULE
V101
COLLABORATION/ CONF
COLLABORATION
COLLABORATION
COLLABORATION
STAIR C
STC1
ELEV LOBBY
C100
KITCHENETTE
MEN'S
G101
WOMEN'S
G100
VESTIBULE
V100
ELEC
CORRIDOR
C103 COPY
CORRIDOR
C102
GENERAL SHEET NOTES
1. REFER TO SHEET FX001 FOR GENERAL NOTES AND
SYMBOLS
2. ALL AREAS ARE CLASSIFIED AS LIGHT HAZARD UNLESS
NOTED OTHERWISE.
3. FIRE SPRINKLER PIPING IS SHOWN FOR REFERENCE
ONLY AND IS INTENDED TO SHOW SYSTEM INTENT. IT IS
THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR
TO DETERMINE FINAL PIPING LAYOUT.
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
M B
I( A
E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
A B
KEY PLAN
324209
FX112
F
IR
E P
R O
T E
C T
IO
N
F
IR
S
T F
L O
O R
P L A
N
A R
E A
B
H A
R P
E R
S F
E R
R Y
W
E S
T V
IR
G
IN
IA
F O
R T
W O
R T
H D
IS
T
R
IC
T T
A Y
L O
R S
T C
T O
F C
R M
A
F O
R T
W O
R T
H T
X
-0
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
L
Y N
D O
N B
J O
H N
S O
N F
W Y
S
U
IT
E
D A
L L A
S T
X
D W
A L T
E R
D W
A L T
E R
J A
S O
N T
A C
K E
T T
O P
A R
K
IN
S O
N
A U
G U
S T
W D
R -2
-R
-0
W G
-1 -D
-0
O P
T
IO
N T
IT
L E
O P
T
IO
N F
IE
L D
R T
A S
U B
M
IS
S
IO
N
IN
S
T R
U C
T
IO
N A
L D
E S
IG
N
C E
N T
E R
D
IS
T
A N
C E
L E
A R
N
IN
G C
E N
T E
R
P N
SCALE: 1/8" = 1'-0"
FIRE PROTECTION - FIRST FLOOR PLAN - AREA B
B7
PLAN NORTH
0 4' 8' 16'
1/8"=1'-0SCALE:
KEYNOTES
1 PROVIDE SIDEWALL SPRINKLERS FOR PROTECTION OF
SHADED AREA.
1 1.1 2 3 3.2 4 5
C
B.9
B.5
B
A.8
A
A.1
AA
OH-1
F X
F X
4.8
2 PERSON OFFICE
OFFICE
OFFICE
DESIGN ROOM 1
DESIGN ROOM 3
OPEN STAFF BAY
ELEV LOBBY
C200
TECH / COMMS
CORRIDOR
C203
LAN/SWITCH
DESIGN ROOM 2
CONFERENCE ROOM
STAIR B
STB1
TELE / COMM
OFFICE
COLLABORATION AREA
CORRIDOR
C202
STAIR A
STA1
CORRIDOR
C204
JAN
ELEV
MECHANICAL
GENERAL SHEET NOTES
1. REFER TO SHEET FX001 FOR GENERAL NOTES AND
SYMBOLS
2. ALL AREAS ARE CLASSIFIED AS LIGHT HAZARD UNLESS
NOTED OTHERWISE.
3. FIRE SPRINKLER PIPING IS SHOWN FOR REFERENCE
ONLY AND IS INTENDED TO SHOW SYSTEM INTENT. IT IS
THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR
TO DETERMINE FINAL PIPING LAYOUT.
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
M B
I( A
E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
A B
KEY PLAN
324210
FX121
F
IR
E P
R O
T E
C T
IO
N
S
E C
O N
D F
L O
O R
P L A
N
A R
E A
A
H A
R P
E R
S F
E R
R Y
W
E S
T V
IR
G
IN
IA
F O
R T
W O
R T
H D
IS
T
R
IC
T T
A Y
L O
R S
T C
T O
F C
R M
A
F O
R T
W O
R T
H T
X
-0
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
L
Y N
D O
N B
J O
H N
S O
N F
W Y
S
U
IT
E
D A
L L A
S T
X
D W
A L T
E R
D W
A L T
E R
J A
S O
N T
A C
K E
T T
O P
A R
K
IN
S O
N
A U
G U
S T
W D
R -2
-R
-0
W G
-1 -D
-0
O P
T
IO
N T
IT
L E
O P
T
IO
N F
IE
L D
R T
A S
U B
M
IS
S
IO
N
IN
S
T R
U C
T
IO
N A
L D
E S
IG
N
C E
N T
E R
D
IS
T
A N
C E
L E
A R
N
IN
G C
E N
T E
R
P N
SCALE: 1/8" = 1'-0"
FIRE PROTECTION - SECOND FLOOR PLAN - AREA A
B6
PLAN NORTH
0 4' 8' 16'
1/8"=1'-0SCALE:
KEYNOTES
1 ELEVATOR HOISTWAY SPRINKLER CONTROL. IN
ACCORDANCE WITH IBC SECTION 3005.5, ELEVATOR
HOISTWAYS AND CONTROLS ROOMS PROTECTED BY
AUTOMATIC SPRINKLERS SHALL HAVE A MEANS
INSTALLED IN ACCORDANCE WITH NFPA 72 SECTION
21.4 TO AUTOMATICALLY DISCONNECT THE MAIN LINE
POWER SUPPLY TO THE AFFECTED ELEVATOR PRIOR
TO THE APPLICATION OF WATER.
2 PROVIDE SPRINKLER PROTECTION AT TOP OF
ELEVATOR HOISTWAY.
3 PROVIDE LISTED GUARDS OVER SPRINKLERS
LOCATED WITHIN ELEVATOR CONTROL ROOM.
6 7 8 9 109.9
C
B.9
B.5
B
A.8
A
A.1
AA
OH-1
F X
F X
OH-1
6.2
GREEN SCREEN / SOUND
STUDIO
OPEN STAFF BAY
CORRIDOR
C205
LAN/SWITCH
DESIGN ROOM 5
2 PERSON OFFICE
OFFICE
DESIGN ROOM 4
DESIGN ROOM 6
STORAGE
205A
STAIR C
STC1
MEN'S
G201
WOMEN'S
G200
KITCHENETTE
ELEC
CORRIDOR
C206
COPY AREA
201.1
UNISEX TLT
G202
MOTHER'S NURSING
CORRIDOR
C201
ELEV DISCONNECT
CLOSET
GENERAL SHEET NOTES
1. REFER TO SHEET FX001 FOR GENERAL NOTES AND
SYMBOLS
2. ALL AREAS ARE CLASSIFIED AS LIGHT HAZARD UNLESS
NOTED OTHERWISE.
3. FIRE SPRINKLER PIPING IS SHOWN FOR REFERENCE
ONLY AND IS INTENDED TO SHOW SYSTEM INTENT. IT IS
THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR
TO DETERMINE FINAL PIPING LAYOUT.
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
M B
I( A
E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
A B
KEY PLAN
324211
FX122
F
IR
E P
R O
T E
C T
IO
N
S
E C
O N
D F
L O
O R
P L A
N
A R
E A
B
H A
R P
E R
S F
E R
R Y
W
E S
T V
IR
G
IN
IA
F O
R T
W O
R T
H D
IS
T
R
IC
T T
A Y
L O
R S
T C
T O
F C
R M
A
F O
R T
W O
R T
H T
X
-0
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
L
Y N
D O
N B
J O
H N
S O
N F
W Y
S
U
IT
E
D A
L L A
S T
X
D W
A L T
E R
D W
A L T
E R
J A
S O
N T
A C
K E
T T
O P
A R
K
IN
S O
N
A U
G U
S T
W D
R -2
-R
-0
W G
-1 -D
-0
O P
T
IO
N T
IT
L E
O P
T
IO
N F
IE
L D
R T
A S
U B
M
IS
S
IO
N
IN
S
T R
U C
T
IO
N A
L D
E S
IG
N
C E
N T
E R
D
IS
T
A N
C E
L E
A R
N
IN
G C
E N
T E
R
P N
SCALE: 1/8" = 1'-0"
FIRE PROTECTION - SECOND FLOOR PLAN - AREA B
B7
PLAN NORTH
0 4' 8' 16'
1/8"=1'-0SCALE:
KEYNOTES
1 PROVIDE FLOW SWITCH AND TAMPER SWITCH FOR
ELEVATOR CONTROL ROOM. IN ACCORDANCE WITH
IBC SECTION 3005.5, ELEVATOR HOISTWAYS AND
CONTROLS ROOMS PROTECTED BY AUTOMATIC
SPRINKLERS SHALL HAVE A MEANS INSTALLED IN
ACCORDANCE WITH NFPA 72 SECTION 21.4 TO
AUTOMATICALLY DISCONNECT THE MAIN LINE POWER
SUPPLY TO THE AFFECTED ELEVATOR PRIOR TO THE
APPLICATION OF WATER.
2 PROVIDE LISTED GUARDS OVER SPRINKLERS
LOCATED WITHIN ELEVATOR CONTROL ROOM.
1. REFER TO SHEET FX001 FOR GENERAL NOTES AND
SYMBOLS
2. FIRE SPRINKLER PIPING IS SHOWN FOR REFERENCE
ONLY AND IS INTENDED TO SHOW SYSTEM INTENT. IT IS
THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR
TO DETERMINE FINAL PIPING LAYOUT.
AA.1 AA
BUTTERFLY VALVE
(NORMALLY CLOSED)
FLOW SWITCH
(TYP)
CHECK VALVE
(TYP)
BUTTERFLY VALVE
(TYP)
DOUBLE CHECK VALVE
BACKFLOW PREVENTER
INCOMING FIRE WATER
SERVICE LATERAL
TO FIRST FLOOR
TO SECOND FLOOR
TO FIRE DEPARTMENT
CONNECTION
TEST HEADER
CHECK VALVE
4 5
A
A.1
J8
FX501
J8
FX501
DOUBLE CHECK
VALVE
BACKFLOW
PREVENTER
SPRINKLER RISERS
4.811
FIRE DEPARTMENT CONNECTION
BACKFLOW PREVENTER
FORWARD
FLOW TEST HEADER
ELEVATOR CAB
ELEVATOR LOBBY
FIRST FLOOR
SECOND FLOOR
SD
ELEVATOR LOBBY
SD
CEILING LINE
CEILING LINE
SPRINKLER
FSTS
1" INSPECTOR'S
TEST STATION
SPRINKLER LINE FROM
2ND FLOOR ZONE SYSTEM
TO ELEVATOR POWER DISCONNECT
SD
SMOKE DETECTOR
FSTS
1" INSPECTOR'S
TEST STATION
SPRINKLER LINE FROM
2ND FLOOR ZONE SYSTEM
TO ELEVATOR POWER DISCONNECT
ELEVATOR CONTROL
ROOM
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
M B
I( A
E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
324212
FX501
F
IR
E P
R O
T E
C T
IO
N
D
E T
A
IL
S
H A
R P
E R
S F
E R
R Y
W
E S
T V
IR
G
IN
IA
F O
R T
W O
R T
H D
IS
T
R
IC
T T
A Y
L O
R S
T C
T O
F C
R M
A
F O
R T
W O
R T
H T
X
-0
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
L
Y N
D O
N B
J O
H N
S O
N F
W Y
S
U
IT
E
D A
L L A
S T
X
D W
A L T
E R
D W
A L T
E R
J A
S O
N T
A C
K E
T T
O P
A R
K
IN
S O
N
A U
G U
S T
W D
R -2
-R
-0
W G
-1 -D
-0
O P
T
IO
N T
IT
L E
O P
T
IO
N F
IE
L D
R T
A S
U B
M
IS
S
IO
N
IN
S
T R
U C
T
IO
N A
L D
E S
IG
N
C E
N T
E R
D
IS
T
A N
C E
L E
A R
N
IN
G C
E N
T E
R
P N
SCALE: NTS
FIRE PROTECTION - FIRE RISER DETAIL
J8
SCALE: NTS
FIRE PROTECTION - ENLARGED RISER PLAN
J1
SCALE:
FIRE PROTECTION - RISER ISOMETRIC
J13
SCALE: NTS
FIRE PROTECTION - ELECTRIC TRACTION ELEVATOR - MACHINE ROOM LESS
B6
NTS
SCALE: NTS
B1
FIRE PROTECTION - ELEVATOR CONTROL
ROOM
1. REFER TO SHEET FX001 FOR GENERAL NOTES AND
SYMBOLS
PIPE DIAMETER
A
B
C
15"
3'-6"
0.600.50
3'-6"
4'-0"
15"
4'-0"
3", 4" & 6"
*D = APPROX. VOLUME OF CONC. IN C.Y.
D*
18"
2'-6"
0.30
2'-6"
15"
3'-0"
0.40
3'-0"
8" 10" 12"
C
C 2"
A
A/2
TRENCH BOTTOM
B
PIPE DIA.
MECHANICAL JOINT WITH
RETAINER GLANDS
SELECT AGGREGATE
MATERIAL
EDGE OF
TRENCH
UNDISTURBED SOIL
CONCRETE ANCHORS FOR
HORIZONTAL 90° BENDS
N.T.S.
SECTIONPLAN
PIPE
SUPPORT NUT
LOCK NUT
HANGER SUPPORT ROD
(SUPPORT FROM STRUCTURE ABOVE)
PLANK
EXPANSION BOLT:
1 1/4" MAX EMBEDMENT
CLEVIS HANGER
(ATR) ALL THREADED ROD
PIPE
24 GAUGE PIPE
SLEEVE TO FIT
SNUGGLY IN HOLE IN
WALL
APPROVED FIRE STOP MATERIAL
RATED PARTITION
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
M B
I( A
E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
324213
FX502
F
IR
E P
R O
T E
C T
IO
N
D
E T
A
IL
S
H A
R P
E R
S F
E R
R Y
W
E S
T V
IR
G
IN
IA
F O
R T
W O
R T
H D
IS
T
R
IC
T T
A Y
L O
R S
T C
T O
F C
R M
A
F O
R T
W O
R T
H T
X
-0
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
L
Y N
D O
N B
J O
H N
S O
N F
W Y
S
U
IT
E
D A
L L A
S T
X
J A
S O
N T
A C
K E
T T
A U
G U
S T
W D
R -2
-R
-0
W G
-1 -D
-0
O P
T
IO
N T
IT
L E
O P
T
IO
N F
IE
L D
R T
A S
U B
M
IS
S
IO
N
IN
S
T R
U C
T
IO
N A
L D
E S
IG
N
C E
N T
E R
D
IS
T
A N
C E
L E
A R
N
IN
G C
E N
T E
R
P N
PROVIDE THRUST BLOCKING
FIRE PROTECTION
WATER SERVICE
RESTRAINING RODS (TYP.)
WATER MAIN.
REFER TO CIVIL SHEETS FOR
CONTINUATION
REFER TO STRUCTURAL
DRAWINGS
FINISHED FLOOR
SLEEVE AND SEAL
FLOOR PENETRATIONS
FIRE SERVICE.
SEE FX501 FOR DETAILS.
F IN FLOOR
PROVIDE T HRUST BLOCKING
SLEEVE AND SEAL
F LOOR PENET RAT IONS
6" F IRE PROTECT ION
WAT ER SERVICE
WAT ER MAIN.
REF ER T O CIVIL DRAWINGS F OR
CONT .
NOT E:
WAT ER ENT RANCE ASSEMBLY MUST BE A MINIMUM OF 12" F ROM WALL.
NOT E:
F IRE SERVICE
SEE FP DWGS F OR
MORE INFORMAT ION
REST RAINING RODS
(TYP)
REF ER T O STRUCTURAL
DRAWINGS
SCALE: NOT TO SCALE
FIRE SERVICE ENTRANCE DETAIL
B1
SCALE: NOT TO SCALE
FIRE PROTECTION - THRUST BLOCK DETAIL
B9
SCALE: NTS
PIPE HANGER DETAIL
K8
SCALE: NTS
INDIVIDUAL PIPE SUPPORT DETAIL
K13
SCALE: NTS
RATED WALL PENETRATION DETAIL
K1
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C H
E C
K E
D B
Y
D W
A L T
E R
D W
A L T
E R
O P
A R
K
IN
S O
N
PLUMBING PIPE LEGEND
SAN
ST
V
PD
TP
ABBREV DESCRIPTIONSYMBOL
CW DOMESTIC COLD WATER
HW DOMESTIC HOT WATER
HWR DOMESTIC HOT WATER
RETURN
PD PUMP DISCHARGE
SAN SANITARY SEWER
ST STORM SEWER
TP TRAP PRIMER PIPING
V SANITARY VENT
CW/GW DOMESTIC COLD WATER /
GRAY WATER
RAD RADON PIPINGRAD
T
PLUMBING SYMBOLS LEGEND
T
DESCRIPTIONSYMBOL
ACCESS PANEL
BALL VALVE
CONNECT TO EXISTING
DIRECTION OF WATER FLOW
DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL
CLEAN-OUT
CLEAN-OUT IN HORIZONTAL
ELBOW 90° DOWN
ELBOW 90° UP
FLEXIBLE CONNECTION
UNION
CAP
TEE DOWN
TEE UP
CHECK VALVE (SWING GATE)
ANGLE GLOBE VALVE
CALIBRATED BALANCE VALVE
THERMOMETER
CONTROL VALVE (3-WAY)
PRESSURE GAUGE WITH GAUGE
COCK
PT (PRESSURE &
TEMPERATURE) TEST PORT
PUMP (ARROW IS DIRECTION OF
FLOW)
P-#
REMOVE EXISTING TO
THERMOSTAT (DASHED LINE
RUNS TO CONTROLLED DEVICE)
TEMPERATURE SENSOR
EJ
FS
BUTTERFLY VALVE
PLUG VALVE
EXPANSION JOINT
GATE VALVE
GLOBE VALVE
PIPING - FLOW SWITCH STRAINER
REDUCER
SOLENOID VALVE
PIPE GUIDE
PIPE ANCHOR
S
T
ELBOW 45°
WALL HYDRANT
ELBOW 90°
WATER HAMMER ARRESTOR
ANGLE GATE VALVE
ELEV PLAN
BACKFLOW PREVENTER
CO
CO
CLEAN-OUT IN VERTICALCO
COMPRESSED AIR OUTLET
DRAIN VALVE
FLOOR CLEAN-OUT
FCO
FILTER/REGULATOR
FILTER
FILTER/REGULATOR/LUBRICATOR
F/R
F/R/L
FLOOR DRAIN W/ P-TRAPOR
FD-# FD-#
GAS REGULATOR
OR
FS-# FS-#
FLOOR SINK W/ P-TRAP
HOSE BIBB
HOSE & QUICK COUPLERS
LUBRICATOR
METER
MIXING VALVE
M
QUICK DISCONNECT
ROOF DRAIN
PRESSURE RELIEF VALVE
(TEMPERATURE & PRESSURE)
PRESSURE REDUCING VALVE
T&P
PRESSURE RELIEF VALVE
(TEMPERATURE)
T
PRESSURE RELIEF VALVE
(PRESSURE)
P
PRESSURE REGULATOR
RD-#
STRAINER WITH VALVED AND
CAPPED BLOW DOWN
TRAP - ELEVATION
TRAP - PLAN
VALVE IN RISE
VENT THROUGH ROOF
WH-#
WHA-X
KEYNOTE
NOTE:
LEGENDS ON THIS SHEET ARE ALL-INCLUSIVE.
ALL SYMBOLS, ABBREVIATIONS, OR PIPE
SYSTEMS MAY NOT BE PART OF THIS PROJECT.
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
M B
I( A
E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
324214
P-001
P L U
M B
IN
G
G E
N E
R A
L N
O T
E S
A
B B
R E
V
IA
T
IO
N S
S
Y M
B O
L S
H A
R P
E R
S F
E R
R Y
W
E S
T V
IG
IN
IA
F O
R T
W O
R T
H D
IS
T
R
IC
T T
A Y
L O
R S
T C
T O
F C
R M
A
F O
R T
W O
R T
H T
X
-0
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
L
Y N
D O
N B
J O
H N
S O
N F
W Y
S
U
IT
E
D A
L L A
S T
X
S H
O R
N
IC
K
S H
O R
N
IC
K
J A
S O
N T
A C
K E
T T
K B
L A
N C
H
A U
G U
S T
W D
R -2
-R
-0
W G
-1 -D
-0
O P
T
IO
N T
IT
L E
O P
T
IO
N F
IE
L D
R T
A S
U B
M
IS
S
IO
N
IN
S
T R
U C
T
IO
N A
L D
E S
IG
N
C E
N T
E R
D
IS
T
A N
C E
L E
A R
N
IN
G C
E N
T E
R
P N
ABB DESCRIPTION
SH SHOWER
SRC SECONDARY RAIN CONDUCTOR
SS SERVICE SINK
STRUC STRUCTURAL
SWC SAFE WASTE CONNECTION
TD TRENCH DRAIN
TE TOP ELEVATION
TEMP TEMPERATURE
TOF TOP OF FOOTING
TOP TOP OF PIPE
TP TRAP PRIMER VALVE
TYP TYPICAL
U URINAL
UNO UNLESS NOTED OTHERWISE
VOL VOLUME
W WASTE
W/ WITH
W/O WITHOUT
WB WASHER BOX
WC
WATER CLOSET, WATER
COLUMN
WF WASH FOUNTAIN
WH WATER HEATER
ABB DESCRIPTION
MAX MAXIMUM
MC MECHANICAL CONTRACTOR
MECH MECHANICAL
MFR / MFGR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MR MOP RECEPTOR
NC NORMALLY CLOSED
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NTS NOT TO SCALE
OB OUTLET BOX
P&T PRESSURE & TEMPERATURE
PC PLUMBING CONTRACTOR
PDI
PLUMBING & DRAINAGE
INSTITUTE
POL PETROLEUM / OIL / LUBRICANT
PSI POUNTS PER SQUARE INCH
QTY QUANTITY
REQ'D REQUIRED
RPM REVOLUTIONS PER MINUTE
RWC RAIN WATER CONDUCTOR
RWL RAIN WATER LEADER
S SINK
SF SQUARE FEET
SFU SUPPLY FIXTURE UNIT(S)
ABB DESCRIPTION
FFE FINISHED FLOOR ELEVATION
FIN FINISHED
FLEX FLEXIBLE
FLR FLOOR
FPM FEET PER MINUTE
FRP
FIBERGLASS REINFORCED
PLASTIC PIPING
FT FOOT, FEET
FTG FOOTING
GA GAUGE
GBD GARBAGE DISPOSAL
GC GENERAL CONTRACTOR
GPM GALLONS PER MINUTE
GWH GAS WATER HEATER
HP HORSE POWER
HTG HEATING
HV HEATING AND VENTILATION
HVAC
HEATING VENTILATION / AIR
CONDITIONING
IE INVERT ELEVATION
IN INCH(ES)
IRH INFRARED RADIANT HEATER
KS KITCHEN SINK
KW KILOWATTS
L LAVATORY
LB(S) POUND(S)
ABB DESCRIPTION
CU FT CUBIC FEET
CUH CABINET UNIT HEATER
CWBT CHILLED WATER BUFFER TANK
CWR CHILLED WATER RETURN
CWS CHILLED WATER SUPPLY
DEG DEGREE(S)
DF DRINKING FOUNTAIN
DFU DRAINAGE FIXTURE UNIT
DIA DIAMETER
DN DOWN
DWG DRAWING
EC ELECTRICAL CONTRACTOR
EL EXPANSION LOOP
ELEC ELECTRIC(AL)
ELEV ELEVATION
ESEW
EMERGENCY SHOWER & EYE
WASH
ET EXPANSION TANK
ETR EXISTING TO REMAIN
EW EMERGENCY EYE WASH
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EX, EXIST EXISTING
(F) FUTURE
F FEHRENHEIT
FCO FLOOR CLEANOUT
ABB DESCRIPTION
ABV ABOVE
AC AIR COMPRESSOR
AD ACCESS DOOR, AIR DRYER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFR ABOVE FINISHED ROOF
AHU AIR HANDLING UNIT
AP ACCESS PANEL
APPROX APPROXIMATE(LY)
ARCH
ARCHITECT OR
ARCHITECTURAL
AST
ABOVE GROUND STORAGE
TANK
BLDG BUILDING
BLW BELOW
BOF BOTTOM OF FOOTING
BOT BOTTOM
C CELSIUS
CB CATCH BASIN
CFH CUBIC FEET PER HOUR
CLG CEILING
CONC CONCRETE
COND CONDENSATION
CONN CONNECTION
CONT CONTINUOUS, CONTINUATION
CONTR CONTRACTOR
PLUMBING ABBREVIATIONS
1. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED, TO INSTALL COMPLETE FOR AN OPERABLE PLUMBING SYSTEM AS INDICATED ON THE DRAWINGS, AS SPECIFIED, AND AS REQUIRED BY CODE. ALL MATERIAL SHALL BE NEW AND OF GOOD QUALITY. ALL WORK SHALL BE INSTALLED IN A NEAT AND
WORKMAN LIKE MANNER.
2. CONTRACT DOCUMENT DRAWINGS FOR PLUMBING WORK ARE DIAGRAMMATIC AND ARE INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. THE LOCATIONS OF ALL ITEMS SHOWN ON THE DRAWINGS OR CALLED FOR IN THE SPECIFICATIONS THAT ARE NOT DEFINITIVELY FIXED BY DRAWING DIMENSIONS ARE APPROXIMATE ONLY. THE EXACT LOCATION NECESSARY TO ACHIEVE THE BEST CONDITIONS AND RESULTS MUST BE DETERMINED BY THE PROJECT SITE CONDITIONS. DO NOT SCALE DRAWINGS. CERTAIN ITEMS SUCH AS RISES AND DROPS IN PIPING, ACCESS DOORS, ETC., ARE INDICATED ON THE CONTRACT DOCUMENT DRAWINGS FOR CLARITY NOT FOR A SPECIFIC LOCATION REQUIREMENT AND SHALL NOT BE INTERPRETED AS THE EXTENT OF THE REQUIREMENTS FOR
THESE TYPES OF ITEMS.
3. INSTALL ALL PLUMBING EQUIPMENT AND APPURTENANCES IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, CONTRACT DOCUMENTS, AND APPLICABLE CODES AND REGULATIONS. COORDINATE ALL EQUIPMENT CONNECTIONS WITH MANUFACTURERS' CERTIFIED DRAWINGS. COORDINATE AND PROVIDE ALL TRANSITIONS REQUIRED FOR FINAL EQUIPMENT CONNECTIONS TO FURNISHED EQUIPMENT. FIELD VERIFY AND COORDINATE ALL PIPING DIMENSIONS BEFORE FABRICATION. LOCATE ALL PLUMBING EQUIPMENT FOR UNOBSTRUCTED ACCESS TO UNIT ACCESS PANELS, CONTROLS, VALVING, ETC.
4. COORDINATE CONSTRUCTION OF ALL PLUMBING WORK WITH ARCHITECTURAL, STRUCTURAL, CIVIL, SOILS, MECHANICAL, ELECTRICAL, COMMUNICATIONS WORK, ETC., AS SHOWN IN OTHER CONTRACT DOCUMENTS. PROPERLY CONSTRUCTED OFFSETS IN PIPING AROUND OBSTRUCTIONS SHALL BE PROVIDED AT NO ADDITIONAL COST. LOCATIONS AND SIZES OF ALL FLOOR, WALL AND ROOF OPENINGS SHALL BE COORDINATED WITH ALL OTHER TRADES INVOLVED.
5. MAINTAIN A MINIMUM OF 6'-8" CLEARANCE TO UNDERSIDE OF PIPES, CONDUITS, SUSPENDED EQUIPMENT, ETC., THROUGHOUT ACCESS ROUTES IN MECHANICAL
ROOMS.
6. ALL TESTS SHALL BE COMPLETED BEFORE ANY EQUIPMENT OR PIPING INSULATION IS APPLIED, OR CONCEALED.
7. LOCATE ALL TEMPERATURE, PRESSURE AND FLOW MEASURING DEVICES IN ACCESSIBLE LOCATIONS WITH A STRAIGHT SECTION OF PIPE UPSTREAM AND
DOWNSTREAM, AS RECOMMENDED BY THE DEVICE MANUFACTURER FOR ACCURACY. INSTALL THERMOMETER IN A VERTICAL AND TILTED POSITION TO ALLOW
READING BY OBSERVER STANDING ON FLOOR.
8. WHERE TWO OR MORE PRODUCTS OF THE SAME TYPE OF EQUIPMENT ARE REQUIRED, THE PRODUCTS OF A SINGLE MANUFACTURER SHALL BE USED.
9. PROVIDE ACCESS PANELS FOR INSTALLATION IN WALLS AND CEILINGS, WHERE REQUIRED, TO SERVICE VALVES AND OTHER CONCEALED PLUMBING EQUIPMENT, DEVICES, ETC. ACCESS PANELS SHALL BE TURNED OVER TO THE GENERAL CONTRACTOR FOR INSTALLATION.
10. ALL OPENINGS IN FIRE RESISTANCE RATED WALLS DUE TO DUCTWORK, PIPING, CONDUIT, ETC., SHALL BE FIRE STOPPED IN ACCORDANCE WITH THE REQUIREMENTS
OF ASTM E 814 & UL 1479. SIMILARLY, SEAL/FIRESTOP AS REQUIRED AT SMOKE RATED SURFACES AS WELL.
11. PROVIDE FLEXIBLE CONNECTIONS IN ALL PIPING CONNECTED TO SUMP PUMP AND OTHER EQUIPMENT WHICH REQUIRES VIBRATION ISOLATION. FLEXIBLE
CONNECTIONS SHALL BE PROVIDED AT THE POINT OF CONNECTION TO THE EQUIPMENT UNLESS OTHERWISE INDICATED.
12. INSTALL PIPING SO THAT ALL VALVES, STRAINERS, UNIONS, TRAPS, FLANGES AND OTHER APPURTENANCES REQUIRING ACCESS ARE EASILY ACCESSIBLE. ALL
VALVES SHALL BE INSTALLED SO THAT THE VALVE REMAINS IN SERVICE WHEN EQUIPMENT OR PIPING ON EQUIPMENT SIDE OF VALVE IS REMOVED.
This is the start of the file's text. The full file is on GovTribe.