B.08.03 Solicitation Amendment 0002 MFRM_SF135.pdf

PDF 273 KB Posted

Attached to
Manhattan Levee Flood Risk Management Project Federal contract opportunity
Solicitation number
W912DQ21B1002
Issued by
Department of the Army Corps of Engineers Engineering District Kansas City

About this file

This document provides details on an upcoming federal construction contract opportunity with the U.S. Army Corps of Engineers Kansas City District. The solicitation will be for construction of updates to the Manhattan Levee Flood Risk Management Project in Manhattan, Kansas, including approximately 14,600 feet of levee raises, underseepage control measures such as relief wells and berms, modification and replacement of drainage structures, and numerous utility relocations. The project value is estimated between $25 million to $100 million. The contract will be awarded through full and open competition utilizing NAICS Code 237990. The performance period for completion of construction is estimated at 913 days. Bids are due on the date and time specified in the solicitation, which is expected to be available on April 21, 2021 through the SAM.gov website. Registered contractors must have an active SAM registration and updated representations and certifications to be considered for award.

View the file

Other files for this federal contract opportunity

Other files attached to Manhattan Levee Flood Risk Management Project, newest first.
File Type Posted
C.04.01 Abstract of Offers.xlsx XLSX spreadsheet
B.08.03 Solicitation Amendment 0004 W912DQ21B1002 (SF 30).pdf PDF
B.08.03 Solicitation Amendment 0004-Attach. G.pdf PDF
B.08.03 Solicitation Amendment-0004 Volume 1 Plans.pdf PDF
B.08.03 Solicitation Amendment 0004-Attach. B.pdf PDF
B.08.03 Solicitation Amendment 0004-Attach I.pdf PDF
B.08.03 Solicitation Amendment-0004 Volume 2 Plans.pdf PDF
B.08.03 Solicitation Amendment 0004-Attach.K.pdf PDF
B.08.03 Solicitation Amendment 003 Volume 1 Plan Sheets Reduced.pdf PDF
B.08.03 Solicitation Amendment 003 Volume 1 Plan Sheets.pdf PDF
B.08.03 Solicitation Amendment 0003 Manhattan Pilot Hole Logs.pdf PDF
B.08.03 Solicitation Amendment 0003 Manhattan Borrow Test Pit Logs.pdf PDF
B.08.03 Solicitation Amendment 0003 SF 30 MFRM Amdt 3 Pg 2.pdf PDF
B.08.03 Solicitation Amendment 0003 Volume 2 Plan Sheets.pdf PDF
B.08.03 Solicitation Amendment 0003 - Spec Attachment N - Div VII Sec 7300.pdf PDF
B.08.03 Solicitation Amendment 0002 How To Obtain CADD Drawing.pdf PDF
B.08.03 Solicitation Amendment 0002 MFRM_CS301.pdf PDF
B.08.03 Solicitation Amendment 0002 MFRM_G-001.pdf PDF
B.08.03 Solicitation Amendment 0002 MFRM_CS501.pdf PDF
B.08.03 Solicitation Amendment 0002 (SF 30).pdf PDF
B.08.03 Solicitation Amendment 0002 Riley Co CUP for Levee Borrow June 2021.pdf PDF
I.01.11 Site Visit Sign-In Sheet.pdf PDF
B.08.03 Solicitation Amendment 0001 (Approved).pdf PDF
B.08.02 MFRM Solicitation and Specifications (6-17-21).pdf PDF
B.08.02 MFRM PLANS - VOLUME 2.pdf PDF
NOTICE TO BIDDERS.docx DOCX document
Manhattan Virtual Industry Day UNOFFICIAL SLIDES.pptx PPTX presentation
A.02.10 Vendors List From Industry Day.xlsx XLSX spreadsheet
A.01.23 Updated Industry Day Information (1).docx DOCX document
A.01.23 Industry Day Information (1).pdf PDF
Show all 30

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1'-0"1'-3"7'-0"1'-3"1'-0"

"3

2' -0

2'-0"

"3

2'-0"

5""2 19"2

19"2 19"2

195"

4'-0"

/4

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

C O

N S

T R

U C

T

IO

N

N O

T F

O R

SHOWN.

HAVE A STANDARD 90° HOOK AS

BELOW PIPE, EF. U-BARS SHALL

PROVIDE INVERTED #6 U-BARS

BAR EF WITH 3" CLEAR COVER.

VERTICAL BAR, ADD ADDITIONAL

AND UNCUT HORIZONTAL OR

COVER EXISTS BETWEEN PIPE

WHERE MORE THAN 6" CLEAR

C923,TYP

CONFORMING TO ASTM

TO JUNCTION BOX,

FOR CONNECTING PIPES

WATERTIGHT CONNECTOR

OR APPROVED EQUAL

PROVIDE A-LOK PREMIUM

LAB WITH WALL REBAR

STANDARD HOOK, TYP

EDGE OF BASE

ELEV. RE: CG110

ELEV. RE: CG110

NOTE:

1. ALL STEEL #6 @ 12" MAX, EW EF

2. WHERE HORIZONTAL BARS ARE TERMINATED DUE TO PIPE PENETRATION

PLACE U-BAR WITH LEGS LAPPING WITH HORIZONTAL REBAR. U-BAR

TO OPEN AWAY FROM PIPE.

CENTERLINE OF PIPES.

INVERT. SLOPE TOWARDS

FILL WITH CONCRETE TO PIPE

GENERAL SHEET NOTES

NOTE:

1. ALL STEEL #6 @ 12" MAX, EW EF

2. 12" RCP NOT SHOWN FOR CLARITY

NOTE:

1. ALL STEEL #6 @ 12" MAX, EW EF

2. 12" RCP NOT SHOWN FOR CLARITY

OF VERT BARS, EF

(2) #6 HOOPS, INSIDE

AROUND, TYP

WATERSTOP ALL

HYDROPHILIC STRIP

LAB WITH WALL REBAR

STANDARD HOOK, TYP

FROM EDGE OF MANHOLE

FROM MAT. 3" CLR CVR

SPACE 6" OC, 45 DEG

ADDITIONAL #6 EF

SEE SHEET NOTE 2

SEE SHEET NOTE 2

PIPE EMBED INTO BASE SLAB

VERT BAR. EF ON EA SIDE OF

ADDITIONAL #6 FULL HEIGHT

NOTE:

1. ALL STEEL #6 @ 12", EW EF

2. (2) #6 HOOPS AROUND ALL INTERSECTING RCP, INSIDE OF VERTICAL BARS. EF.

3. CLSM OVER FOOTER EXTENSION BENEARTH 48" PIPES. SEE A1/SF505 FOR DETAILS.

4. LADDER RUNGS NOT SHOWN FOR CLARITY.

SEE DETAIL NOTE 3

INDIVIDUAL LADDER RUNGS

REFER TO SHEET NOTE 4

REMAINING RUNGS NOT

SHOWN FOR CLARITY

FOR OPENING

SEE DETAIL 1

SIDE VIEWFRONT VIEW

1/4

TYP

SHEAR STUDS 4"X1/2" (TYP)

4X4X1/2" (TYP)

4X4X1/2" (TYP)

3.5"X1/2" PLATE (TYP)

NOTE:

1. HOT DIPPED GALVANIZED

2. VERTICAL ANGLES REQUIRE

INTERIOR LEG CORNERS TO BE

CLIPPED (2X2)

3. ALL PLATES 3.5"X1/2"

CENTER PL ON

ANGLES

1. FOR GENERAL STRUCTURAL NOTES SEE SHEET S-001.

2. ACCESS FRAME AND LID SHALL BE NEENAH R-1900-E OR APPROVED EQUAL.

3. SLOPE TOP SLABS TO DRAIN.

4. INSTALL LADDER RUNGS DESIGNED AND DETAILED IN ACCORDANCE

WITH 29 CFR 1910.23. THE LADDER RUNG DESIGN, INCLUDING

ANCHORAGE, SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR

AND SHALL BE DESIGNED TO MEET 29 CFR 1910.23 AND SPECIFICATION

SECTION 05 51 33. FOR POST-INSTALLED ANCHORAGE, GPR SHALL BE

USED TO LOCATE REBAR AND ANCHOR HOLES DRILLED TO MISS REBAR.

MAINTAIN 3" CLEAR COVER TO PIPE WALL.

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg2:30:32 PM 7/12/2021

...\Manhattan Levee Improvements\6.0 Engineering-Design\6.1 Drawings\CAD_BIM\_Sheets\MH-A2 JUNCTION BOX STA. 254+55

F Y

F

IL

E N

A M

E

SF135

S E

E C

O V

E R S

H E

E T

M A

N H

A T

T A

N U

N

IT

L

E V

E E R

A

IS

E

K A

N S

A S R

IV

E R F

L O

O D P

R O

T E

C T

IO

N P

R O J E

C T

S E

E C

O V

E R S

H E

E T

K A

N S

A S C

IT

Y

M O

E T

H S

T R

E E

T

K A

N S

A S C

IT

Y D

IS

T R

IC

T

D

R A

W

IN

G C

O D

E

D R

A W

IN

G

C O

E

J U

N E

A N

S I

D

A S

V

IT

A K

S

A

M H -A

J

U N

C T

IO

N B

O X

C

B R

E C

K W

O L

D T

F S

H E

F F

IE

L

M F

R M

S

F .d g n

C

B R

E C

K W

O L

D

D1

SCALE: 1/2" = 1'

SECTION

0 2' 4'1' D6

PLAN VIEW

0 2' 4'1'

A1

SCALE: 1/2" = 1' 0 2' 4'1' A6

0 2' 4'1'

SCALE: 1/2" = 1' 0 2' 4'1'

DETAIL 1