This solicitation notice is for the construction of a facility renovation project located within Building 9201 at Tinker Air Force Base, Oklahoma. The project scope includes offices, conference rooms, entry ways, visitor control, restrooms, open office space, cubicles, a break room, mechanical room, electrical room, communications room, and general circulation space. Structural, mechanical, electrical, and fire suppression upgrades are also part of the project scope. The estimated construction duration is 545 calendar days. This requirement will be set aside as a 100% small business opportunity. A site visit is scheduled for June 30, 2022, with notification of attendance requested by June 28. The anticipated solicitation closing date is July 22, 2022.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

21 22

PD

PD.5

PE

VESTIBULE

LOBBY

STORAGE

LACTATION

MEN'S

WOMEN'S

JAN.

MEN'S

WOMEN'S

STOR.

GRP

DIRECTOR

LG SUP

SEC SUP

ADMIN

FM

DIRECTOR

CONFERENCE

PK DIRECTOR

DEP

DIRECTOR

LG SUP

IT SUP

CORRIDOR

100C 100D

100A 100B

128 129 130

131124

125 126 127 133 132

134A

1A-400

16 1616

16 1416

7' - 2" 7' - 8"

10' - 5" 10' - 5" 25' - 6 3/4" 10' - 5" 10' - 5" 10' - 4"

17' - 5" 35' - 2 1/2"

C O

R R

ID

O

R

18' - 1" 2' - 6"

LV-3

MATCHLINEMATCHLINE

M A

T C

H L

IN

E M

A T

C H

L

IN

E

FA/MN

CORRIDOR

122 137123

6' - 4"

1' - 0" 1' - 0"

6' - 4"

1A-310

5' - 6"

11' - 5"

12' - 2"

IT STORAGE

1A-570

1A-550

1A-550

1A-550

1A-550

1A-551

SERVER

1A-552

20.5 21.5

1A-311

Sim

INDICATES DOOR NUMBER.

REFER TO DOOR SCHEDULE ON SHEET 1A-600.

INDICATES WINDOW TYPE. REFER TO SHEET 1A-510.

INDICATES LOUVER TYPE. REFER TO SHEET 1A-530.

INDICATES WALL TYPE CONSTRUCTION.

REFER TO SHEET 1A-540.

INDICATES (1) HOUR RATED WALL. REFER TO LIFE

SAFETY PLANS.

FLOOR INFILL. REFER TO STRUCTURAL

DRAWINGS AND DETAIL 10/1A-580.

1FB

ARCHITECTURAL LEGEND

WAG KEY PLAN

B

A

C

D

E

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

F

IL

E N

A M

E

1A-111

P A

R T

IA

L F

L O

O R

P L A

N A

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K L A

H O

M A

M B

A R

N E

T T

K R

IG

G

S

W F

O Y

A M c C

O Y

A P

R

IL

R E

A D

Y T

O A

D V

E R

T

IS

E

A F

L C

M C

F A

C

IL

IT

Y

D E

S

IG

N B

U

IL

D

IN

G

T U

L S

A D

IS

T

R

IC

T T

U L S

A O

K L A

H O

M A

N o n e A

-1 .d w g

W A

G G

R O

U P

SCALE: 1/8" = 1'-0"1A-111

1 PARTIAL FLOOR PLAN A

SHEET KEYNOTES

1 SURFACE MOUNTED ENTRY MAT.

2 NOT USED.

3 6" RAISED ACCESS FLOORING STEPS, 2'-0" TIERED

SEATING. REFER TO DETAILS ON SHEET 1A-580.

4 SEMI-RECESSED FIRE EXTINGUISHER CABINET WITH A

10lb. (4A:80B:C) FIRE EXTINGUISHER. (TO BE ONE HOUR

RATED WHEN INSTALLED IN RATED WALLS). REFER TO

DETAIL 1/1A-580.

5 SURFACE MOUNTED FIRE EXTINGUISHER BRACKET.

MOUNT BOTTOM AT 27" A.F.F. MAXIMUM.

6 TAPE, SKIM COAT AND SAND ALL JOINTS, CORNERS AND

SCREW HEADS IN PREPARATION FOR PAINT.

7 PRE-MANUFACTURED FREE-STANDING ENTRANCE

CANOPY. OFFSET 2" FROM EXISTING EXTERIOR METAL

WALL PANEL.

8 1-1/2" PAINTED HANDRAIL/GUARDRAIL.

9 SURFACE MOUNTED FIRE EXTINGUISHER CABINET WITH

10 LBS. (4A:80B:C) FIRE EXTINGUISHER. REFER TO DETAIL

1/1A-580.

10 PROVIDE A 5'-5" WIDE X 8'-6" HIGH FRAMED OPENING IN

THE WALL FOR FUTURE CORRIDOR. REFER TO HEADER

DETAIL 6/1A-543. FRAMED OPENING SHALL MEET SECURE

AREA PERIMETER WALL CONSTRUCTION BUT SHALL BE

CONSTRUCTED SO THAT THE OPENING CAN BE

DEMOLISHED IN THE FUTURE WITHOUT DISTURBING THE

SECURE AREA PERIMETER WALL CONSTRUCTION

11 2-HOUR RATED, STC 50 EXPANSION JOINT WITH

COMPRESSIBLE GASKET AT 4" GAP BETWEEN NEW AND

EXISTING FLOOR SLABS. REFER TO STRUCTURAL

DRAWINGS.

12 REFER TO DETAIL 7/1A-543 FOR EXPANSION JOINT WALL

DETAIL.

13 REFER TO 1I-111 FOR ACOUSTICAL WALL LOCATION AND

INFORMATION. REFER TO 1A-141 FOR ATTACHMENT

INFORMATION.

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

/1 /2

21 22

PC

PD

PC.5

PK OFFICE

OPEN OFFICE

OPEN OFFICE

135A

136B

134B

136A

4 4

12' - 4" 12' - 4" 19' - 4" 19' - 8 3/4" 12' - 4" 10' - 4"

55' - 5" 6' - 6"

1A-310

C O

R R

ID

O

R

CORRIDOR

MATCHLINEMATCHLINE

MATCHLINEMATCHLINE

M A

T C

H L

IN

E

153A

SUPER

152A

SUPER

154A

SUPER

135A

SUPER

135B

154B153B152B

153A 154A

OPEN OFFICE

134A

12' - 4" 136D

1' - 4"

1' - 6"

4' - 4"

1A-550

1A-550

1A-550

1A-550

1A-550

IPT OFFICE

CORRIDOR

1A-552

1A-550

10' - 8" 136C

136A

SUPER

1A-551

1A-552

20.5 21.5

M A

T C

H L

IN

E

INDICATES DOOR NUMBER.

REFER TO DOOR SCHEDULE ON SHEET 1A-600.

INDICATES WINDOW TYPE. REFER TO SHEET 1A-510.

INDICATES LOUVER TYPE. REFER TO SHEET 1A-530.

INDICATES WALL TYPE CONSTRUCTION.

REFER TO SHEET 1A-540.

INDICATES (1) HOUR RATED WALL. REFER TO LIFE

SAFETY PLANS.

FLOOR INFILL. REFER TO STRUCTURAL

DRAWINGS AND DETAIL 10/1A-580.

1FB

ARCHITECTURAL LEGEND

WAG KEY PLAN

B

A

C

D

E

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

F

IL

E N

A M

E

1A-112

P A

R T

IA

L F

L O

O R

P L A

N B

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K L A

H O

M A

M B

A R

N E

T T

K R

IG

G

S

W F

O Y

A M c C

O Y

A P

R

IL

R E

A D

Y T

O A

D V

E R

T

IS

E

A F

L C

M C

F A

C

IL

IT

Y

D E

S

IG

N B

U

IL

D

IN

G

T U

L S

A D

IS

T

R

IC

T T

U L S

A O

K L A

H O

M A

N o n e A

-1 .d w g

W A

G G

R O

U P

SCALE: 1/8" = 1'-0"1A-112

1 PARTIAL FLOOR PLAN B

SHEET KEYNOTES

1 SURFACE MOUNTED ENTRY MAT.

2 NOT USED.

3 6" RAISED ACCESS FLOORING STEPS, 2'-0" TIERED

SEATING. REFER TO DETAILS ON SHEET 1A-580.

4 SEMI-RECESSED FIRE EXTINGUISHER CABINET WITH A

10lb. (4A:80B:C) FIRE EXTINGUISHER. (TO BE ONE HOUR

RATED WHEN INSTALLED IN RATED WALLS). REFER TO

DETAIL 1/1A-580.

5 SURFACE MOUNTED FIRE EXTINGUISHER BRACKET.

MOUNT BOTTOM AT 27" A.F.F. MAXIMUM.

6 TAPE, SKIM COAT AND SAND ALL JOINTS, CORNERS AND

SCREW HEADS IN PREPARATION FOR PAINT.

7 PRE-MANUFACTURED FREE-STANDING ENTRANCE

CANOPY. OFFSET 2" FROM EXISTING EXTERIOR METAL

WALL PANEL.

8 1-1/2" PAINTED HANDRAIL/GUARDRAIL.

9 SURFACE MOUNTED FIRE EXTINGUISHER CABINET WITH

10 LBS. (4A:80B:C) FIRE EXTINGUISHER. REFER TO DETAIL

1/1A-580.

10 PROVIDE A 5'-5" WIDE X 8'-6" HIGH FRAMED OPENING IN

THE WALL FOR FUTURE CORRIDOR. REFER TO HEADER

DETAIL 6/1A-543. FRAMED OPENING SHALL MEET SECURE

AREA PERIMETER WALL CONSTRUCTION BUT SHALL BE

CONSTRUCTED SO THAT THE OPENING CAN BE

DEMOLISHED IN THE FUTURE WITHOUT DISTURBING THE

SECURE AREA PERIMETER WALL CONSTRUCTION

11 2-HOUR RATED, STC 50 EXPANSION JOINT WITH

COMPRESSIBLE GASKET AT 4" GAP BETWEEN NEW AND

EXISTING FLOOR SLABS. REFER TO STRUCTURAL

DRAWINGS.

12 REFER TO DETAIL 7/1A-543 FOR EXPANSION JOINT WALL

DETAIL.

13 REFER TO 1I-111 FOR ACOUSTICAL WALL LOCATION AND

INFORMATION. REFER TO 1A-141 FOR ATTACHMENT

INFORMATION.

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

/1 /2

1 1

INDICATES DOOR NUMBER.

REFER TO DOOR SCHEDULE ON SHEET 1A-600.

INDICATES WINDOW TYPE. REFER TO SHEET 1A-510.

INDICATES LOUVER TYPE. REFER TO SHEET 1A-530.

INDICATES WALL TYPE CONSTRUCTION.

REFER TO SHEET 1A-540.

INDICATES (1) HOUR RATED WALL. REFER TO LIFE

SAFETY PLANS.

FLOOR INFILL. REFER TO STRUCTURAL

DRAWINGS AND DETAIL 10/1A-580.

1FB

ARCHITECTURAL LEGEND

18 19

PC

PD

PB.6

PC.5

CYBER

OFFICE139

IPT OFFICE

SUPPORT

COPIER

SOURCE

SELECTION

ROOM

SMALL

CONFERENCE

VESTIBULE

BREAKOUT

SMALL

CONFERENCE

VEST

138A

141142

149B

149A

16 16

44 436' - 6" 34' - 6" 31' - 8"

5' - 5" 5' - 6" 29' - 0"

7' - 0" 15' - 1" 9' - 0" 10' - 11" 29' - 0" 12' - 4"

32' - 4" 34' - 10"

13' - 0"

139A

MATCHLINEMATCHLINE

MATCHLINE

M A

T C

H L

IN

E M

A T

C H

L

IN

E

151A

SUPER

138A

SUPER139A

SUPER

CORRIDOR

151B

151A

139B

OPEN OFFICE

LARGE

CONFERENCE

152A

138B

5 5

10' - 8" 11' - 2"

10' - 8 1/8"

/8 " 2' - 8"

/8

149C

149A

MEDIA

ELECTRICAL

1A-551

1A-551

OPP

1A-551

SIM SIM

1A-551

SIM

1A-550

1A-551

1A-550

1A-550

1A-550

1A-550

SIM

11111111

17.5 18.5 19.5

WAG KEY PLAN

B

A

C

D

E

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

F

IL

E N

A M

E

1A-113

P A

R T

IA

L F

L O

O R

P L A

N C

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K L A

H O

M A

M B

A R

N E

T T

K R

IG

G

S

W F

O Y

A M c C

O Y

A P

R

IL

R E

A D

Y T

O A

D V

E R

T

IS

E

A F

L C

M C

F A

C

IL

IT

Y

D E

S

IG

N B

U

IL

D

IN

G

T U

L S

A D

IS

T

R

IC

T T

U L S

A O

K L A

H O

M A

N o n e A

-1 .d w g

W A

G G

R O

U P

SCALE: 1/8" = 1'-0"1A-113

1 PARTIAL FLOOR PLAN C

SHEET KEYNOTES

1 SURFACE MOUNTED ENTRY MAT.

2 NOT USED.

3 6" RAISED ACCESS FLOORING STEPS, 2'-0" TIERED

SEATING. REFER TO DETAILS ON SHEET 1A-580.

4 SEMI-RECESSED FIRE EXTINGUISHER CABINET WITH A

10lb. (4A:80B:C) FIRE EXTINGUISHER. (TO BE ONE HOUR

RATED WHEN INSTALLED IN RATED WALLS). REFER TO

DETAIL 1/1A-580.

5 SURFACE MOUNTED FIRE EXTINGUISHER BRACKET.

MOUNT BOTTOM AT 27" A.F.F. MAXIMUM.

6 TAPE, SKIM COAT AND SAND ALL JOINTS, CORNERS AND

SCREW HEADS IN PREPARATION FOR PAINT.

7 PRE-MANUFACTURED FREE-STANDING ENTRANCE

CANOPY. OFFSET 2" FROM EXISTING EXTERIOR METAL

WALL PANEL.

8 1-1/2" PAINTED HANDRAIL/GUARDRAIL.

9 SURFACE MOUNTED FIRE EXTINGUISHER CABINET WITH

10 LBS. (4A:80B:C) FIRE EXTINGUISHER. REFER TO DETAIL

1/1A-580.

10 PROVIDE A 5'-5" WIDE X 8'-6" HIGH FRAMED OPENING IN

THE WALL FOR FUTURE CORRIDOR. REFER TO HEADER

DETAIL 6/1A-543. FRAMED OPENING SHALL MEET SECURE

AREA PERIMETER WALL CONSTRUCTION BUT SHALL BE

CONSTRUCTED SO THAT THE OPENING CAN BE

DEMOLISHED IN THE FUTURE WITHOUT DISTURBING THE

SECURE AREA PERIMETER WALL CONSTRUCTION

11 2-HOUR RATED, STC 50 EXPANSION JOINT WITH

COMPRESSIBLE GASKET AT 4" GAP BETWEEN NEW AND

EXISTING FLOOR SLABS. REFER TO STRUCTURAL

DRAWINGS.

12 REFER TO DETAIL 7/1A-543 FOR EXPANSION JOINT WALL

DETAIL.

13 REFER TO 1I-111 FOR ACOUSTICAL WALL LOCATION AND

INFORMATION. REFER TO 1A-141 FOR ATTACHMENT

INFORMATION.

SCALE: NTS

LARGE CONFERENCE ROOM 149 - ISOMETRIC2

1A-113

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

/1 /2

18 19

PD

PD.5

PE

CORRIDOR

BREAKROOM

COMM

ELECTRICAL

TRAINING

CORRIDOR

IT BUILD

CORRIDOR

112B113115

114 112A

116B

117 118

116A

MECHANICAL

7' - 5" 29' - 0" 23' - 0" 7' - 3" 25' - 10"

7' - 5" 4' - 0" 17' - 0" 15' - 8" 40' - 0" 22' - 0"

14 14

116C116C

1A-420

LV-1LV-2

MATCHLINE

M A

T C

H L

IN

E

UNCLASSIFIED

WORK AREA

MAN TRAP

VISITOR

CONTROL

SECURITY

119A

119B

14 14 14

1' - 0" 22' - 6" 10' - 2" 3' - 4"

1' - 9"

6' - 4" 5' - 3" 11' - 6"

3' - 0"

5' - 0"

A

2' - 0"

1' - 0"

SERVER

1A-551

1A-551

1A-551

1A-551

1A-550

1A-550

1A-551

SIM

MATCHLINE

M A

T C

H L

IN

E

17.5 18.5 19.5

INDICATES DOOR NUMBER.

REFER TO DOOR SCHEDULE ON SHEET 1A-600.

INDICATES WINDOW TYPE. REFER TO SHEET 1A-510.

INDICATES LOUVER TYPE. REFER TO SHEET 1A-530.

INDICATES WALL TYPE CONSTRUCTION.

REFER TO SHEET 1A-540.

INDICATES (1) HOUR RATED WALL. REFER TO LIFE

SAFETY PLANS.

FLOOR INFILL. REFER TO STRUCTURAL

DRAWINGS AND DETAIL 10/1A-580.

1FB

ARCHITECTURAL LEGEND

WAG KEY PLAN

B

A

C

D

E

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

F

IL

E N

A M

E

1A-114

P A

R T

IA

L F

L O

O R

P L A

N D

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K L A

H O

M A

M B

A R

N E

T T

K R

IG

G

S

W F

O Y

A M c C

O Y

A P

R

IL

R E

A D

Y T

O A

D V

E R

T

IS

E

A F

L C

M C

F A

C

IL

IT

Y

D E

S

IG

N B

U

IL

D

IN

G

T U

L S

A D

IS

T

R

IC

T T

U L S

A O

K L A

H O

M A

N o n e A

-1 .d w g

W A

G G

R O

U P

SCALE: 1/8" = 1'-0"1A-114

1 PARTIAL FLOOR PLAN D

SHEET KEYNOTES

1 SURFACE MOUNTED ENTRY MAT.

2 NOT USED.

3 6" RAISED ACCESS FLOORING STEPS, 2'-0" TIERED

SEATING. REFER TO DETAILS ON SHEET 1A-580.

4 SEMI-RECESSED FIRE EXTINGUISHER CABINET WITH A

10lb. (4A:80B:C) FIRE EXTINGUISHER. (TO BE ONE HOUR

RATED WHEN INSTALLED IN RATED WALLS). REFER TO

DETAIL 1/1A-580.

5 SURFACE MOUNTED FIRE EXTINGUISHER BRACKET.

MOUNT BOTTOM AT 27" A.F.F. MAXIMUM.

6 TAPE, SKIM COAT AND SAND ALL JOINTS, CORNERS AND

SCREW HEADS IN PREPARATION FOR PAINT.

7 PRE-MANUFACTURED FREE-STANDING ENTRANCE

CANOPY. OFFSET 2" FROM EXISTING EXTERIOR METAL

WALL PANEL.

8 1-1/2" PAINTED HANDRAIL/GUARDRAIL.

9 SURFACE MOUNTED FIRE EXTINGUISHER CABINET WITH

10 LBS. (4A:80B:C) FIRE EXTINGUISHER. REFER TO DETAIL

1/1A-580.

10 PROVIDE A 5'-5" WIDE X 8'-6" HIGH FRAMED OPENING IN

THE WALL FOR FUTURE CORRIDOR. REFER TO HEADER

DETAIL 6/1A-543. FRAMED OPENING SHALL MEET SECURE

AREA PERIMETER WALL CONSTRUCTION BUT SHALL BE

CONSTRUCTED SO THAT THE OPENING CAN BE

DEMOLISHED IN THE FUTURE WITHOUT DISTURBING THE

SECURE AREA PERIMETER WALL CONSTRUCTION

11 2-HOUR RATED, STC 50 EXPANSION JOINT WITH

COMPRESSIBLE GASKET AT 4" GAP BETWEEN NEW AND

EXISTING FLOOR SLABS. REFER TO STRUCTURAL

DRAWINGS.

12 REFER TO DETAIL 7/1A-543 FOR EXPANSION JOINT WALL

DETAIL.

13 REFER TO 1I-111 FOR ACOUSTICAL WALL LOCATION AND

INFORMATION. REFER TO 1A-141 FOR ATTACHMENT

INFORMATION.

SCALE: NTS1A-114

CORRIDOR 107 - UTILITIES2

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

/1 /2

INDICATES DOOR NUMBER.

REFER TO DOOR SCHEDULE ON SHEET 1A-600.

INDICATES WINDOW TYPE. REFER TO SHEET 1A-510.

INDICATES LOUVER TYPE. REFER TO SHEET 1A-530.

INDICATES WALL TYPE CONSTRUCTION.

REFER TO SHEET 1A-540.

INDICATES (1) HOUR RATED WALL. REFER TO LIFE

SAFETY PLANS.

FLOOR INFILL. REFER TO STRUCTURAL

DRAWINGS AND DETAIL 10/1A-580.

1FB

ARCHITECTURAL LEGEND21 22

PB.6

PB

PA.3

PA

20' - 0" 8

18' - 2" 10' - 4"

VESTIBULE

FIRE RISER

CORRIDOR

157B

1A-200

MATCHLINE

M A

T C

H L

IN

E

1A-570

1A-551

157A

MATCHLINE

20.5 21.5

WAG KEY PLAN

B

A

C

D

E

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

F

IL

E N

A M

E

1A-115

P A

R T

IA

L F

L O

O R

P L A

N E

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K L A

H O

M A

M B

A R

N E

T T

K R

IG

G

S

W F

O Y

A M c C

O Y

A P

R

IL

R E

A D

Y T

O A

D V

E R

T

IS

E

A F

L C

M C

F A

C

IL

IT

Y

D E

S

IG

N B

U

IL

D

IN

G

T U

L S

A D

IS

T

R

IC

T T

U L S

A O

K L A

H O

M A

N o n e A

-1 .d w g

W A

G G

R O

U P

SHEET KEYNOTES

1 SURFACE MOUNTED ENTRY MAT.

2 NOT USED.

3 6" RAISED ACCESS FLOORING STEPS, 2'-0" TIERED

SEATING. REFER TO DETAILS ON SHEET 1A-580.

4 SEMI-RECESSED FIRE EXTINGUISHER CABINET WITH A

10lb. (4A:80B:C) FIRE EXTINGUISHER. (TO BE ONE HOUR

RATED WHEN INSTALLED IN RATED WALLS). REFER TO

DETAIL 1/1A-580.

5 SURFACE MOUNTED FIRE EXTINGUISHER BRACKET.

MOUNT BOTTOM AT 27" A.F.F. MAXIMUM.

6 TAPE, SKIM COAT AND SAND ALL JOINTS, CORNERS AND

SCREW HEADS IN PREPARATION FOR PAINT.

7 PRE-MANUFACTURED FREE-STANDING ENTRANCE

CANOPY. OFFSET 2" FROM EXISTING EXTERIOR METAL

WALL PANEL.

8 1-1/2" PAINTED HANDRAIL/GUARDRAIL.

9 SURFACE MOUNTED FIRE EXTINGUISHER CABINET WITH

10 LBS. (4A:80B:C) FIRE EXTINGUISHER. REFER TO DETAIL

1/1A-580.

10 PROVIDE A 5'-5" WIDE X 8'-6" HIGH FRAMED OPENING IN

THE WALL FOR FUTURE CORRIDOR. REFER TO HEADER

DETAIL 6/1A-543. FRAMED OPENING SHALL MEET SECURE

AREA PERIMETER WALL CONSTRUCTION BUT SHALL BE

CONSTRUCTED SO THAT THE OPENING CAN BE

DEMOLISHED IN THE FUTURE WITHOUT DISTURBING THE

SECURE AREA PERIMETER WALL CONSTRUCTION

11 2-HOUR RATED, STC 50 EXPANSION JOINT WITH

COMPRESSIBLE GASKET AT 4" GAP BETWEEN NEW AND

EXISTING FLOOR SLABS. REFER TO STRUCTURAL

DRAWINGS.

12 REFER TO DETAIL 7/1A-543 FOR EXPANSION JOINT WALL

DETAIL.

13 REFER TO 1I-111 FOR ACOUSTICAL WALL LOCATION AND

INFORMATION. REFER TO 1A-141 FOR ATTACHMENT

INFORMATION.

SCALE: 1/8" = 1'-0"1A-115

1 PARTIAL FLOOR PLAN E

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

/1 /2

17 18 19 21 22

PC

PD

PD.5

PE

PB.6

PB

PA.3

PA

PC.5

PE.5

210' - 4"

/2

18' - 2"

198' - 1"

17.2

17.5 18.5 19.5 20.5 21.5

WAG KEY PLAN

B

A

C

D

E

GRAPHIC SCALE: = 1'-0"

16' 08' 32' 48'16'

1/16"GRAPHIC SCALE: = 1'-0"

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

F

IL

E N

A M

E

1A-120

C O

M P

O S

IT

E

S E

C O

N D

F L O

O R

P L A

N

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K L A

H O

M A

M B

A R

N E

T T

K R

IG

G

S

W F

O Y

A M c C

O Y

A P

R

IL

R E

A D

Y T

O A

D V

E R

T

IS

E

A F

L C

M C

F A

C

IL

IT

Y

D E

S

IG

N B

U

IL

D

IN

G

T U

L S

A D

IS

T

R

IC

T T

U L S

A O

K L A

H O

M A

N o n e A

-1 .d w g

W A

G G

R O

U P

SCALE: 1/16" = 1'-0"

COMPOSITE SECOND FLOOR PLAN

SHEET KEYNOTES

1 INSTALL LOOSE LAID 1" MINERAL FIBER INSULATION ON

TOP OF FLOOR SLAB. SET EACH PIECE TIGHT AGAINST

EACH OTHER AT HATCHED AREA.

2 PROVIDE 2-HOUR RATED EXPANSION JOINT WITH

COMPRESSIBLE GASKET AT 4" GAP BETWEEN NEW AND

EXISTING FLOOR SLABS. REFER TO DETAIL 5/1S-351.

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

/1 /2

ARCHITECTURAL LEGEND

2'-0"X 2'-0" SUSPENDED ACOUSTICAL CEILING

SUSPENDED GYPSUM BOARD CEILING (WATER

RESISTANT IN RESTROOMS)

EXPOSED CEILING

4'-0" SURFACE MOUNTED LED

2'-0" X 2'-0" LED

LED FIXTURE

EMERGENCY LIGHTING

EXIT SIGN

AIR TERMINAL: SUPPLY/RETURN/EXHAUST

EMERGENCY EXTERIOR LIGHT

1-HOUR FIRE RATED GYPSUM BOARD CEILING CAP

21 22

PD

PD.5

PE

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

MATCHLINEMATCHLINE

M A

T C

H L

IN

E M

A T

C H

L

IN

E

9' - 0"

9' - 0"

9' - 0"

EXP

EXP

9' - 0"

19.5 20.5 21.5

9' - 0"

EXP

9' - 0"

WAG KEY PLAN

B

A

C

D

E

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

F

IL

E N

A M

E

1A-141

P A

R T

IA

L R

E F

L E

C T

E D

C E

IL

IN

G P

L A

N A

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K L A

H O

M A

M B

A R

N E

T T

K R

IG

G

S

W F

O Y

A M c C

O Y

A P

R

IL

R E

A D

Y T

O A

D V

E R

T

IS

E

A F

L C

M C

F A

C

IL

IT

Y

D E

S

IG

N B

U

IL

D

IN

G

T U

L S

A D

IS

T

R

IC

T T

U L S

A O

K L A

H O

M A

N o n e A

-1 .d w g

W A

G G

R O

U P

SCALE: 1/8" = 1'-0"1A-141

1 PARTIAL REFLECTED CEILING PLAN - A

SHEET KEYNOTES

1 BULKHEAD, REFER TO DETAIL 1/1A-560.

2 SOFFIT, REFER TO DETAIL 2/1A-560.

3 EXTRUDED ALUMINUM FLAT SOFFIT DECKING.

4 EXPANSION JOINT. REFER TO DETAIL 3/1A-560.

5 EXPANSION JOINT. REFER TO DETAIL 4/1A-560.

6 1-HOUR FIRE RATED CEILING AT 9'-5". REFER TO DETAIL

5/1A-560.

7 1-HOUR FIRE RATED CEILING CAP AT 16'-0" A.F.F.

8 AWP-01 IS A 12" WIDE X 102" HEIGHT 2 SIDED PRINT

ACOUSTIC BAFFLE. USE BAFFLE CUP HOOKS TO ATTACH

TO CEILING GRID FOR INSTALLATION. STABLIZED BY

ADJUSTABLE CABLE 5' WIRE LENGTH WITH T-BAR TWIST

CLIP THREADED WITH BASE. BAFFLES WILL BE CLIPPED

TO U-CHANEL. U-CHANELS ARE TO BE BOLTED OR

ADHERRED TO FLOOR. U-CHANELS TO BE CUT ON SITE.

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

/1 /2

PE

AC04

AC01

AC01

(TYP)

AC02

AC02

AC07

AC08

AC04

AC04

AC09

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

AC06

LACTATION

JAN.

MEN'S

WOMEN'S

STOR.

WOMEN'S

MEN'S

AC09

AC07

AC07

AC08

8 9

10 1010

8 8

7 12

101010

11 11

7 12

101010

8' - 6" 1' - 6" 8' - 6"

1' - 4" 10' - 1" 8' - 6" 1' - 6" 8' - 6" 5' - 8" 1' - 4" 7' - 4"

/8

/8

1' - 4"

14' - 4 1/8"

/2

23' - 5"

1A-400

1A-400

1A-420

AC02

AC10

AC10

AC01

AC02

AC02

AC01

AC08

AC07

AC02

AC02

AC01

AC01

AC08

AC09

AC04

1A-401

1A-401

1A-401

AC03

(TYP)

AC05

(TYP)

AC01

AC01

AC03

AC03

AC11

AC11

20.5

AC08

FIRST FLOOR

100' - 0"

AC04

AC07

AC08

AC09

AC08

4 56

(TYP)

AC04

AC03 AC03

TYP.

1' - 6"

FIRST FLOOR

100' - 0"

TYP

AC02

3AC01

1A-401

AC02

AC01

8' - 0 5/8" 8' - 0 5/8"

TYP

GRAPHIC SCALE: = 1'-0"

2' 01' 4' 6'2'

1/2"GRAPHIC SCALE: = 1'-0"

4' 02' 8' 12'4'

GRAPHIC SCALE: = 1'-0"1/4"GRAPHIC SCALE: = 1'-0"

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

F

IL

E N

A M

E

1A-400

E N

L A

R G

E D

R E

S T

R O

O M

P L A

N A

N D

E L E

V A

T

IO

N S

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K L A

H O

M A

M B

A R

N E

T T

K R

IG

G

S

W F

O Y

A M c C

O Y

A P

R

IL

R E

A D

Y T

O A

D V

E R

T

IS

E

A F

L C

M C

F A

C

IL

IT

Y

D E

S

IG

N B

U

IL

D

IN

G

T U

L S

A D

IS

T

R

IC

T T

U L S

A O

K L A

H O

M A

N o n e A

-4 .d w g

W A

G G

R O

U P

SCALE: 1/4" = 1'-0"1A-400

ENLARGED RESTROOM, JANITOR AND

LACTATION ROOM PLAN

SHEET KEYNOTES

1 COUNTER TOP MOUNTED LAVATORY.

2 SOLID SURFACE COUNTER WITH BACKSPLASH AT 3

SIDES.

3 MIRROR, REFER TO ELEVATION FOR SIZE. NO WALL TILE

BEHIND MIRROR.

4 ABA COMPLIANT URINAL.

5 ABA COMPLIANT WATER CLOSET.

6 18" X 42" HDPE (HIGH DENSITY POLYETHYLENE) FLOOR

SUPPORTED URINAL SCREEN.

7 FLOOR SUPPORTED OVERHEAD BRACED HDPE (HIGH

DENSITY POLYETHYLENE) TOILET PARTITION WITH 1

ROBE HOOK ON EACH DOOR.

8 12" X 12" X 1/4" ACCESS PANEL INTO CHASE. REFER TO

DETAIL 5/1A-401.

9 ABA COMPLIANT HI-LOW WATER COOLER WITH BOTTLE

FILLER. REFER TO DETAIL 4/1A-580 AND PLUMBING

DRAWINGS.

10 UTILITY MOP SINK. REFER TO PLUMBING DRAWINGS.

11 SOFFIT ABOVE. REFER TO DETAIL 2/1A-560.

12 SINGLE BOWL POLISHED STAINLESS STEEL SINK.

13 UNDER COUNTER REFRIGERATOR.

14 COUNTERTOP WITH BACKSPLASH AT WALL SURFACES.

15 BASE CABINETS.

16 2-HOUR RATED EXPANSION JOINT WITH COMPRESSIBLE

GASKET AT 4" GAP BETWEEN NEW AND EXISTING FLOOR

SLABS. REFER TO STRUCTURAL DRAWINGS AND DETAIL

3/1A-560.

17 REFER TO DETAIL 7/1A-543 FOR EXPANSION JOINT WALL

DETAIL.

ACCESSORY SCHEDULE

AC01 SURFACE MOUNTED SOAP DISPENSER.(GFGI)

AC02 SURFACE MOUNTED PAPER TOWEL DISPENSER.(GFGI)

AC03 SURFACE MOUNTED TOILET SEAT COVER DISPENSER.

AC04 SURFACE MOUNTED TOILET TISSUE DISPENSER.(GFGI)

AC05 SURFACE MOUNTED SANITARY NAPKIN DISPOSAL

AC06 SURFACE MOUNTED UTILITY SHELF WITH MOP AND

BROOM HOLDER.

AC07 3'-0" GRAB BAR, MOUNT CENTER AT 2'-9".

AC08 3'-6" GRAB BAR, MOUNT CENTER AT 2'-9".

AC09 18" VERTICAL GRAB BAR, MOUNT BOTTOM AT 3'-3" A.F.F.

AC10 24" X 60" MIRROR. MOUNT BOTTOM AT 18" A.F.F.

AC11 24" X 30" MIRROR. MOUNT BOTTOM AT 40" A.F.F.

SCALE: 1/2" = 1'-0"1A-400

2 MEN'S 108 RESTROOM ELEVATION

SCALE: 1/2" = 1'-0"1A-400

3 WOMEN'S 109 RESTROOM ELEVATION

1. REFER TO FINISH SCHEDULE ON SHEET 1A-610.

2. REFER TO FINISH KEY ON SHEET 1A-611 FOR TOILET

PARTITION, URINAL SCREENS, AND COUNTER TOP

FINISHES.

3. REFER TO PLUMBING DRAWINGS FOR PLUMBING

FIXTURES.

4. ALL DIMENSIONS ARE MEASURED TO FACE OF STUD ON

PLANS AND GYPSUM BOARD ON ELEVATIONS.

5. FIELD VERIFY WALL DIMENSION ABOVE LAVATORIES

FOR LOCATION OF MIRROR PRIOR TO INSTALLATION.

6. PROVIDE FIRE RETARDANT TREATED SOLID WOOD

BLOCKING IN WALL BEHIND ALL ACCESSORIES AND

MIRRORS FOR MOUNTING.

7. PROVIDE CONTINUOUS ANGLE MOUNTING BRACKETS

FOR ALL TOILET PARTITIONS AND URINAL

INSTALLATION.

8. FLOOR TILE SHALL EXTEND THROUGHOUT ROOM ON

ALL FLOOR SURFACES.

9. PROVIDE COAT HOOKS ON TOILET COMPARTMENT

DOORS PER SPECIFICATION.

10. ALL EXPOSED PIPES UNDER LAVATORIES SHALL BE

COVERED WITH PREFABRICATED INSULATING

ANTIMICROBIAL VINYL. THERE SHALL BE NO SHARP

EDGES OR ABRASIVE SURFACES UNDER LABATORIES.

COLOR SHALL MATCH BROCAR PRODUCT'S INC'S "TRAP

WRAP" IN STANDARD WHITE.

11. RESTROOM ACCESSORIES SHALL BE MOUNTED WITH

THEIR DISPENSING MECHANISMS OR OPENINGS

LOCATED 38" - 54" UNLESS OTHERWISE SPECIFIED.

12. AC-xx NUMBERS IN THE ACCESSORIES LEGEND

REFERENCE A SCHEDULE NUMBER IN THE 10 28 13

TOILET ACCESSORIES SPECIFICATION.

13. SLOPE FLOOR TO DRAINS. REFER TO PLUMBING

DRAWINGS FOR DRAIN LOCATIONS AND STRUCTURAL

DRAWINGS FOR DRAIN DETAILS.

GENERAL NOTES

LEGEND

INDICATES DOOR NUMBER. REFER TO DOOR

SCHEDULE ON SHEET A-600.

INDICATES WALL TYPE CONSTRUCTION. REFER TO

SHEET A-540.

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

/1 /2

2'-0"

1'-9 3/4"

3/4"

1 1/2"

SUSPENDED 5/8" WATER RESISTANT

GYPSUM BOARD CEILING

EXTEND STUDS TO UNDERSIDE

OF DECK AND SEAL

3 5/8" METAL STUD AT 16" O.C.

ACOUSTICAL SOUND BATT INSULATION

5/8" CEMENTITIOUS BACKER BOARD (TYP.)

LIGHT DIFFUSER. REFER TO

ELECTRICAL FOR LIGHT FIXTURE.

MIRROR. REFER TO

ELEVATIONS FOR SIZE

SOLID SURFACE COUNTER TOP

WITH 4" BACK SPLASH AT 3 SIDES

1A-401

1A-560

1/2"

1/2"

/2

SOUND BATT INSULATION

1'-11"

METAL STUDS AT 16"

O.C. (REFER TO WALL TYPES

FOR SIZE OF STUDS)

SOLID SURFACE COUNTER

WITH 4" BACK SPLASH AT 3 SIDES,

REFER TO FINISH SCHEDULE

3/4" PLYWOOD

5/8" CEMENTITIOUS BACKER

BOARD

SOLID SURFACE APRON

WITH WOOD BLOCKING

SOLID SURFACE APRON

VANITY SKIRT

PROVIDE SOLID SURFACE

SUPPORT BRACKETS MINIMUM

OF 3 SUPPORTS ON COUNTERS

GREATER THAN 8'-2"

WALL TILE, REFER TO

FINISH SCHEDULE

1A-401

MIRROR

5/8" CEMENTITIOUS

BACKER BOARD

STAINLESS STEEL

MIRROR FRAME

PROVIDE FIRE

RETARDANT-

TREATED

WOOD BLOCKING

METAL STUDS AT

16" O.C. (REFER TO

WALL TYPES FOR

SIZE OF STUDS)

SOLID SURFACING

BACKSPLASH

3/4" PLYWOOD

2' - 0"

1'-0"

/4

EDGE OF TILE

BEHIND ACCESS

PANEL

ACCESS PANEL

ANCHORS (TYP.)

1A-401

ANCHOR (TYP.)

ACCESS PANEL

SOUND BATT INSULATION

5/8" CEMENTITIOUS BACKER

BOARD

METAL STUDS AT

16" O.C. (REFER TO

WALL TYPES FOR

SIZE OF STUDS)

WALL TILE,

REFER TO FINISH

SCHEDULE

WOOD BLOCKING

(BEYOND)

WALL TILE

(BEYOND)

2"x4" FIRE

RETARDANT-

TREATED

WOOD BLOCKING

FIRST FLOOR

100' - 0"

AC04

AC07

AC08

AC09

AC02

1' - 6"

AC03

AC11

1' - 6"

FIRST FLOOR

100' - 0"

"2

AC04

AC07 AC08

AC09

AC03

AC05

FIRST FLOOR

100' - 0"

AC02

AC01

AC04

AC08

AC07

AC03

GRAPHIC SCALE: = 1'-0"

4" 2" 0 4" 8" 1'

3"GRAPHIC SCALE: = 1'-0"

GRAPHIC SCALE: = 1'-0"

2' 01' 4' 6'2'

1/2"GRAPHIC SCALE: = 1'-0"

GRAPHIC SCALE: = 1'-0"

1' 06" 2' 3'1'

1"GRAPHIC SCALE: = 1'-0"

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

F

IL

E N

A M

E

1A-401

R E

S T

R O

O M

D E

T A

IL

S

A N

D E

L E

V A

T

IO

N S

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K L A

H O

M A

M B

A R

N E

T T

K R

IG

G

S

W F

O Y

A M c C

O Y

A P

R

IL

R E

A D

Y T

O A

D V

E R

T

IS

E

A F

L C

M C

F A

C

IL

IT

Y

D E

S

IG

N B

U

IL

D

IN

G

T U

L S

A D

IS

T

R

IC

T T

U L S

A O

K L A

H O

M A

N o n e A

-4 .d w g

W A

G G

R O

U P

SCALE: 1/2" = 1'-0"1A-401

1 SECTION

SCALE: 1" = 1'-0"1A-401

2 SECTION

SCALE: 3" = 1'-0"1A-401

3 BLOCKING DETAIL

SCALE: 1/2" = 1'-0"1A-401

4 MIRROR DETAIL

SCALE: 1" = 1'-0"1A-401

5 RESTROOM ACCESS PANEL DETAIL

SCALE: 3" = 1'-0"1A-401

6 RESTROOM ACCESS PANEL SECTION

SCALE: 1/2" = 1'-0"1A-401

8 MEN'S 104 RESTROOM ELEVATION

SCALE: 1/2" = 1'-0"1A-401

7 WOMEN'S 105 RESTROOM ELEVATION

SCALE: 1/2" = 1'-0"1A-401

9 MEN'S 108 RESTROOM ELEVATION

ACCESSORY SCHEDULE

AC01 SURFACE MOUNTED SOAP DISPENSER.(GFGI)

AC02 SURFACE MOUNTED PAPER TOWEL DISPENSER.(GFGI)

AC03 SURFACE MOUNTED TOILET SEAT COVER DISPENSER.

AC04 SURFACE MOUNTED TOILET TISSUE DISPENSER.(GFGI)

AC05 SURFACE MOUNTED SANITARY NAPKIN DISPOSAL

AC06 SURFACE MOUNTED UTILITY SHELF WITH MOP AND

BROOM HOLDER.

AC07 3'-0" GRAB BAR, MOUNT CENTER AT 2'-9".

AC08 3'-6" GRAB BAR, MOUNT CENTER AT 2'-9".

AC09 18" VERTICAL GRAB BAR, MOUNT BOTTOM AT 3'-3" A.F.F.

AC10 24" X 60" MIRROR. MOUNT BOTTOM AT 18" A.F.F.

AC11 24" X 30" MIRROR. MOUNT BOTTOM AT 40" A.F.F.

SHEET KEYNOTES

1 COUNTER TOP MOUNTED LAVATORY.

2 SOLID SURFACE COUNTER WITH BACKSPLASH AT 3

SIDES.

3 MIRROR, REFER TO ELEVATION FOR SIZE. NO WALL TILE

BEHIND MIRROR.

4 ABA COMPLIANT URINAL.

5 ABA COMPLIANT WATER CLOSET.

6 18" X 42" HDPE (HIGH DENSITY POLYETHYLENE) FLOOR

SUPPORTED URINAL SCREEN.

7 FLOOR SUPPORTED OVERHEAD BRACED HDPE (HIGH

DENSITY POLYETHYLENE) TOILET PARTITION WITH 1

ROBE HOOK ON EACH DOOR.

8 12" X 12" X 1/4" ACCESS PANEL INTO CHASE. REFER TO

DETAIL 5/1A-401.

9 ABA COMPLIANT HI-LOW WATER COOLER WITH BOTTLE

FILLER. REFER TO DETAIL 4/1A-580 AND PLUMBING

DRAWINGS.

10 UTILITY MOP SINK. REFER TO PLUMBING DRAWINGS.

11 SOFFIT ABOVE. REFER TO DETAIL 2/1A-560.

12 SINGLE BOWL POLISHED STAINLESS STEEL SINK.

13 UNDER COUNTER REFRIGERATOR.

14 COUNTERTOP WITH BACKSPLASH AT WALL SURFACES.

15 BASE CABINETS.

16 2-HOUR RATED EXPANSION JOINT WITH COMPRESSIBLE

GASKET AT 4" GAP BETWEEN NEW AND EXISTING FLOOR

SLABS. REFER TO STRUCTURAL DRAWINGS AND DETAIL

3/1A-560.

17 REFER TO DETAIL 7/1A-543 FOR EXPANSION JOINT WALL

DETAIL.

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

/1 /2

PE

1A-420

BREAKROOM

FIRST FLOOR

100' - 0"2' - 3"1' - 9"

1A-420

1A-420

SIM SIM

3' - 0" 2' - 0" 3' - 0" 3' - 0" 2' - 0"

3' - 0" 2' - 0" 3' - 0" 3' - 0" 2' - 0"

1A-420

1A-420

1A-420

3/4" FINISHED MELAMINE CASE WITH

PVC EDGE, DRILLED FOR ADJUSTABLE

SHELF CLIPS. EXPOSED ENDS OF

CASEWORK SHALL BE PLASTIC

LAMINATE FINISH. PVC EDGE SHALL

COORDINATE WITH LAMINATE.

3/4" MDF, PLASTIC LAMINATE

CLAD DOOR WITH COORDINATING

PVC EDGE. REFER TO SPECIAL ITEMS KEY.

3/4" ADJUSTABLE MELAMINE

SHELVES WITH PVC EDGE,

ROUTED TO ACCEPT RECESSED

SHELF CLIPS/PINS.

3/4" MDF, PLASTIC LAMINATE

CLAD DRAWER FRONT WITH COORDINATING

PVC EDGE. REFER TO SPECIAL ITEMS KEY.

1' - 0"

2' - 1"

/2

2' - 0"

3"

1/2" SOLID SURFACE COUNTER TOP WITH

BACK SPLASH. REFER TO SPECIAL ITEMS

KEY.

3/4" FOUR SIDED MELAMINE DRAWER BOX

WITH PVC EDGE AND CAPTURED BOTTOM.

DRAWER GLIDES SHALL BE FULL EXTENSION

UNDER MOUNT. PVC EDGE SHALL

COORDINATE WITH DRAWER BOX.

3/4" FINISHED MELAMINE CASE WITH PVC

EDGE, DRILLED FOR ADJUSTABLE SHELF

CLIPS. EXPOSED ENDS OF CASEWORK SHALL

BE PLASTIC LAMINATE FINISH. PVC EDGE

SHALL COORDINATE WITH LAMINATE.

3/4" ADJUSTABLE MELAMINE

SHELVES WITH PVC EDGE,

ROUTED TO ACCEPT RECESSED

SHELF CLIPS/PINS.

3/4" MDF, PLASTIC LAMINATE

CLAD DOOR WITH COORDINATING

PVC EDGE. REFER TO SPECIAL ITEMS KEY.

3/4" KICK PLATE.

RUBBER BASE, REFER TO FINISH KEY.

3/4" FINISHED MELAMINE CASE WITH

PVC EDGE, DRILLED FOR ADJUSTABLE

SHELF CLIPS. EXPOSED ENDS OF

CASEWORK SHALL BE PLASTIC

LAMINATE FINISH. PVC EDGE SHALL

COORDINATE WITH LAMINATE.

3/4" MDF, PLASTIC LAMINATE

CLAD DOOR WITH COORDINATING

PVC EDGE. REFER TO SPECIAL ITEMS KEY.

3/4" ADJUSTABLE MELAMINE

SHELVES WITH PVC EDGE,

ROUTED TO ACCEPT RECESSED

SHELF CLIPS/PINS.

1/2" SOLID SURFACE COUNTER TOP

WITH BACK SPLASH. REFER TO SPECIAL ITEMS

KEY.

3/4" FOUR SIDED MELAMINE DRAWER BOX WITH

PVC EDGE AND CAPTURED BOTTOM. DRAWER

GLIDES SHALL BE FULL EXTENSION UNDER

MOUNT. PVC EDGE SHALL COORDINATE WITH

DRAWER BOX.

3/4" FINISHED MELAMINE CASE WITH PVC

EDGE, DRILLED FOR ADJUSTABLE SHELF CLIPS.

EXPOSED ENDS OF CASEWORK SHALL BE

PLASTIC LAMINATE FINISH. PVC EDGE SHALL

COORDINATE WITH LAMINATE.

3/4" MDF, PLASTIC LAMINATE

CLAD DRAWER FRONT WITH COORDINATING

PVC EDGE. REFER TO SPECIAL ITEMS KEY.

(TYPICAL)

3/4" KICK PLATE.

RUBBER BASE, REFER TO FINISH KEY.

2' - 0" 3"

/2

2' - 1"

1' - 6 1/2"

2' - 1"

/2

3"

2' - 0"

3/4" FINISHED MELAMINE CASE WITH

PVC EDGE, DRILLED FOR ADJUSTABLE

SHELF CLIPS. EXPOSED ENDS OF

CASEWORK SHALL BE PLASTIC

LAMINATE FINISH. PVC EDGE SHALL

COORDINATE WITH LAMINATE.

3/4" MDF, PLASTIC LAMINATE

CLAD DOOR WITH COORDINATING

PVC EDGE. REFER TO SPECIAL ITEMS KEY.

PLASTIC LAMINATE COUNTER TOP WITH

BACK SPLASH. REFER TO SPECIAL ITEMS

KEY.

3/4" FOUR SIDED MELAMINE DRAWER

BOX WITH PVC EDGE AND CAPTURED

BOTTOM. DRAWER GLIDES SHALL BE

FULL EXTENSION UNDER MOUNT. PVC

EDGE SHALL COORDINATE WITH

DRAWER BOX.

3/4" FINISHED MELAMINE CASE WITH

PVC EDGE, DRILLED FOR ADJUSTABLE

SHELF CLIPS. EXPOSED ENDS OF

CASEWORK SHALL BE PLASTIC

LAMINATE FINISH. PVC EDGE SHALL

COORDINATE WITH LAMINATE.

3/4" ADJUSTABLE MELAMINE

SHELVES WITH PVC EDGE, ROUTED

TO ACCEPT RECESSED SHELF

CLIPS/PINS.

3/4" MDF, PLASTIC LAMINATE

CLAD DOOR WITH COORDINATING

PVC EDGE. REFER TO SPECIAL ITEMS

KEY.

3/4" KICK PLATE.

RUBBER BASE, REFER TO FINISH KEY.

1' - 0"

3/4" MDF, PLASTIC LAMINATE CLAD SHELF.

4' 02' 8' 12'4'

GRAPHIC SCALE: = 1'-0"1/4"GRAPHIC SCALE: = 1'-0"

GRAPHIC SCALE: = 1'-0"

2' 01' 4' 6'2'

1/2"GRAPHIC SCALE: = 1'-0"

GRAPHIC SCALE: = 1'-0"

1' 06" 2' 3'1'

1"GRAPHIC SCALE: = 1'-0"

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

F

IL

E N

A M

E

1A-420

E N

L A

R G

E D

B R

E A

K R

O O

M P

L A

N

E L E

V A

T

IO

N S

A N

D D

E T

A

IL

S

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K L A

H O

M A

M B

A R

N E

T T

K R

IG

G

S

W F

O Y

A M c C

O Y

A P

R

IL

R E

A D

Y T

O A

D V

E R

T

IS

E

A F

L C

M C

F A

C

IL

IT

Y

D E

S

IG

N B

U

IL

D

IN

G

T U

L S

A D

IS

T

R

IC

T T

U L S

A O

K L A

H O

M A

N o n e A

-4 .d w g

W A

G G

R O

U P

SCALE: 1/4" = 1'-0"1A-420

1 ENLARGED BREAKROOM PLAN

SHEET KEYNOTES

1 DOUBLE BOWL POLISHED STAINLESS STEEL SINK.

2 BASE AND UPPER CABINETS.

3 MICROWAVE. (N.I.C.)

4 REFRIGERATOR. REF-1 (N.I.C.)

5 VENDING MACHINES. (N.I.C.)

6 COFFEE MAKER. CM-1 (N.I.C.)

7 ABA COMPLIANT HI-LOW WATER COOLER WITH BOTTLE

FILLER. REFER TO DETAIL 4/1A-580 AND PLUMBING

DRAWINGS.

8 SINGLE BOWL POLISHED STAINLESS STEEL SINK.

9 UNDER COUNTER REFRIGERATOR.

10 COUNTERTOP WITH BACKSPLASH AT WALL SURFACES.

11 BASE CABINETS.

12 SURFACE MOUNTED SOAP DISPENSER.(GFCI)

13 ICE MAKER. IM-1 (N.I.C.)

14 CELL PHONE LOCKERS. REFER TO DETAILS ON SHEET

1A-581.

SCALE: 1/2" = 1'-0"1A-420

2 LACTATION ELEVATION

SCALE: 1/2" = 1'-0"1A-420

3 BREAKROOM ELEVATION

1. REFER TO SPECIAL ITEM KEY FOR CABINET AND

COUNTER AND COUNTER TOP FINISH.

2. BACK SPLASHES, AND END SPLASHES SHALL MATCH

COUNTER TOP.

3. PROVIDE 20ga METAL STUDS AND BLOCKING IN AREAS OF WALL MOUNTED ITEMS (TVs, MONITORS, PROJECTION SCREENS, ETC). REFER TO ELECTRICAL

AND FURNITURE PLANS.

GENERAL SHEET NOTES

LEGEND

INDICATES DOOR NUMBER. REFER TO DOOR

SCHEDULE ON SHEET 1A-600.

INDICATES WALL TYPE CONSTRUCTION. REFER TO

SHEET 1A-540.

INDICATES (1) HOUR RATED WALL. REFER TO LIFE

SAFETY PLANS.

SCALE: 1" = 1'-0"1A-420

4 CASEWORK SECTION

SCALE: 1" = 1'-0"1A-420

5 CASEWORK SECTION

SCALE: 1" = 1'-0"1A-420

6 CASEWORK SECTION

1FB

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

/1 /2

3 5/8" 3 5/8"

3 5/8"

3 5/8"3 5/8"

SECURE PERIMETER WALL

STC TESTED RATING = 50

1 HOUR RATED U.L. U465

3-5/8" METAL STUD AT 16" O.C.

EXTEND TO DECK AND SECURE

ACOUSTICAL BLANKET

INSULATION

5/8" MOLD AND MOISTURE

RESISTANT GYPSUM BOARD.

EXTEND TO DECK AND SEAL

CROSS BRACING AS REQUIRED

CEILING. REFER TO REFLECTED

CEILING PLANS

5/8" MOLD AND MOISTURE

RESISTANT GYPSUM BOARD.

EXTEND TO 4" ABOVE CEILING

3-5/8" METAL STUD AT 16" O.C.

EXTEND TO 6" ABOVE CEILING

ACOUSTICAL BLANKET

INSULATION

CROSS BRACING AS

REQUIRED

CEILING. REFER TO

REFLECTED CEILING PLANS

3-5/8" METAL STUD AT

16" O.C. EXTEND TO 6"

ABOVE CEILING

ACOUSTICAL BLANKET

INSULATION

CROSS BRACING AS

REQUIRED

CEILING. REFER TO

REFLECTED CEILING PLANS

ACOUSTICAL BLANKET

INSULATION

5/8" CEMENTITIOUS BACKER

BOARD, EXTEND TO 4" ABOVE

CEILING

3-5/8" METAL STUD AT 16" O.C.

EXTEND TO 6" ABOVE CEILING

WALL TILE, REFER TO

FINISH SCHEDULE

CROSS BRACING AS REQUIRED

CEILING. REFER TO

REFLECTED CEILING PLANS

5/8" CEMENTITIOUS BACKER

BOARD, EXTEND TO 4" ABOVE

CEILING

WALL TILE, REFER TO FINISH

SCHEDULE

3-5/8" METAL STUD AT 16" O.C.

EXTEND TO 6" ABOVE CEILING

ACOUSTICAL BLANKET

INSULATION

6 7

11 12

6" CROSS BRACING AS

REQUIRED

CEILING. REFER TO

REFLECTED CEILING PLANS

5/8" CEMENTITIOUS BACKER

BOARD, EXTEND TO 4" ABOVE

CEILING

WALL TILE, REFER TO FINISH

SCHEDULE

6" METAL STUD AT 16" O.C.

EXTEND TO 6" ABOVE CEILING

ACOUSTICAL BLANKET INSULATION

5/8" MOLD AND MOISTURE

RESISTANT GYPSUM BOARD.

EXTEND 4" ABOVE CEILING

5/8" MOLD AND MOISTURE

RESISTANT GYPSUM BOARD.

EXTEND 4" ABOVE CEILING

3 5/8"

5/8" MOLD AND MOISTURE

RESISTANT GYPSUM BOARD.

EXTEND TO DECK AND SEAL

3-5/8" METAL STUD AT 16" O.C.

ACOUSTICAL BLANKET INSULATION

STC=45

3 5/8"

CROSS BRACING AS

REQUIRED

CEILING. REFER TO

REFLECTED CEILING PLANS

ACOUSTICAL BLANKET INSULATION

5/8" CEMENTITIOUS BACKER

BOARD, EXTEND TO 4" ABOVE

CEILING

3-5/8" METAL STUD AT 16" O.C.

EXTEND TO 6" ABOVE CEILING

WALL TILE, REFER TO

FINISH SCHEDULE

10"

5/8" MOLD AND MOISTURE

RESISTANT GYPSUM BOARD.

EXTEND TO DECK AND SEAL

3-5/8" METAL STUD AT 16" O.C.

EXISTING 2" INSULATED METAL

PANEL

1' - 11" 3 5/8"

5/8" MOLD AND MOISTURE

RESISTANT GYPSUM BOARD.

EXTEND TO DECK AND SEAL

3-5/8" METAL STUD AT 16" O.C.

EXISTING 2" INSULATED METAL

PANEL

1' - 5"

COL

1' - 8 5/8" 6"

5/8" CEMENTITIOUS BACKER BOARD,

EXTEND TO DECK AND SEAL

6" METAL STUD AT 16" O.C.

EXTEND TO DECK AND SECURE

EXISTING 2" INSULATED METAL

PANEL

1' - 5"

COL

WALL TILE, REFER TO FINISH

SCHEDULE

ACOUSTICAL BLANKET INSULATION

3 5/8"

3-5/8" METAL STUD AT 16" O.C.

EXTEND TO DECK AND SECURE

ACOUSTICAL BLANKET

INSULATION

5/8" MOLD AND MOISTURE

RESISTANT TYPE 'X' GYPSUM

BOARD. EXTEND TO DECK AND

SEAL

1 HOUR RATED

U.L. U465

METAL ROOF DECK

5/8" MOLD AND MOISTURE

RESISTANT GYPSUM BOARD

EXTEND TO 4" ABOVE CEILING.

SECURE PERIMETER WALL

STC TESTED RATING = 50

(2) LAYERS OF 5/8" MOLD AND MOISTURE

RESISTANTTYPE "X" GYPSUM BOARD,

EXTEND TO DECK AND SEAL

3-5/8" METAL STUD AT 16" O.C.

ACOUSTICAL BLANKET INSULATION

(2) LAYERS OF 5/8" ACOUSTICAL

RATED GYPSUM BOARD, EXTEND

TO DECK AND SEAL

ULTRA RADIANT R-FOIL

SANDWICHED

BETWEEN THE TWO LAYERS

NOT USED

REFER TO DETAIL 6/1A-542

FOR DEEP LEG CHANNEL

DETAIL

3" SPRAY FOAM INSULATION 3" SPRAY FOAM INSULATION 3" SPRAY FOAM INSULATION

3 5/8"

(2) LAYERS OF 5/8" MOLD AND

MOISTURE RESISTANT TYPE "X"

GYPSUM BOARD, EXTEND TO DECK

AND SEAL

3-5/8" METAL STUD AT 16" O.C.

ACOUSTICAL BLANKET INSULATION

ULTRA RADIANT R-FOIL

SANDWICHED

BETWEEN THE TWO LAYERS

ACOUSTICAL BLANKET INSULATION

ACOUSTICAL BLANKET INSULATION

3 5/8"

(2) LAYERS 5/8" MOLD AND

MOISTURE RESISTANT TYPE 'X'

GYPSUM BOARD. EXTEND TO DECK

AND SEAL

3-5/8" METAL STUD AT 16" O.C.

ACOUSTICAL BLANKET INSULATION

(2) LAYERS OF 5/8 ACOUSTICAL

RATED GYPSUM BOARD. EXTEND

TO DECK AND SEAL

3 5/8"

STC=50

(2) LAYERS OF 5/8" ACOUSTICAL

RATED GYPSUM BOARD. EXTEND TO

DECK AND SEAL.

1. REFER TO SHEETS 1A-541 THROUGH 1A-543

FOR MISCELLANEOUS METAL STUD DETAILS.

2. REFER TO FINISH SCHEDULE FOR WALL

FINISHES.

3. PROVIDE STRAP BRACING IN WALLS AS

NEEDED FOR LATERAL BRACING OF WALLS.

4. ALL PENETRATIONS IN WALLS SHALL BE

SEALED. AT THE SECURE PEREMITER AND STC

RATED WALLS PROVIDE ACOUSTICAL

SEALANT.

5. PROVIDE 18ga METAL STUDS FOR WALLS THAT

RECEIVE CEMENTITIOUS BACKER BOARD AND

WALL TILE.

6. ON TYPICAL NON RATED WALLS, EXTEND

METAL STUDS 6" ABOVE CEILING. PROVIDE

DIAGONAL BRACING AT 48" O.C. TO

STRUCTURE ABOVE UNLESS OTHERWISE

NOTED.

7. FIRE RATED WALL ASSEMBLIES SHALL EXTEND

TO THE UNDERSIDE OF DECK ABOVE AND BE

SEALED WITH FIRE STOPPING MATERIAL. ALL

PENETRATIONS IN FIRE WALLS SHALL BE FIRE

STOPPED. REFER TO PARTIAL PLANS FOR FIRE

WALL LOCATIONS.

8. ALL FIRE-RATED WALLS SHALL BE

EFFECTIVELY AND PERMANENTLY IDENTIFIED

WITH STENCILING. REFER TO DETAIL 4/1A-543.

9. SECURE AREA PERIMETER WALL TYPES SHALL

BE CONSTRUCTED PER IC TECH SPEC ICD/ICS

705:

-INSTALL ONE LAYER OF 5/8" TYPE "X" GYPSUM

BOARD APPLIED TO THE CONTROLLED AREA

SIDE OF WALL. ATTACH WITH 1" TYPE "S"

DRYWALL SCREWS 8" O.C. AT PERIMETER OF

BOARD AND 12" O.C. TO INTERMEDIATE STUDS.

-INSTALL ULTRA RADIANT R-FOIL TO GYPSUM

BOARD

- INSTALL THE FACE LAYER OF 5/8" GYPSUM

BOARD (ON CONTROLLED AREA SIDE) OVER

THE TYPE "X" GYPSUM BOARD. ATTACH WITH

LAMINATING COMPOUND AND WITH 1-5/8" TYPE

"S" DRYWALL SCREWS 8" O.C. AT PERIMETER

OF BOARD AND 12" O.C. TO INTERMEDIATE

STUDS. (STAGGER SEAMS, 50% OFFSET FROM

ALIGNMENT).

- INSTALL 3-1/2"ACOUSTICAL GLASS FIBER

INSULATION IN CAVITY. BATTEN SHALL BE

FASTENED TO PREVENT IT FROM SLIDING

DOWN AND LEAVING A VOID AT THE TOP.

- PER SECURE AREA REQUIREMENTS, ENTIRE

SECURE PERIMETER WALL ASSEMBLY SHALL

BE PAINTED FROM TRUE FLOOR TO TRUE

CEILING.

- SEAL TOP AND BOTTOM OF WALL ON BOTH

SIDES WITH ACOUSTICAL FOAM OR SEALANT.

-SEAL ALL PENETRATIONS WITH ACOUSTICAL

FOAM OR SEALANT ON BOTH SIDES OF WALL,

COLUMN, ANOTHER WALL, ETC.

- GSSO SHALL CHECK EACH WALL LAYER

(GYPSUM BOARD, INSULATION, ETC) AND

APPROVE THE CONSTRUCTION PRIOR TO

CONTRACTOR PROCEEDING WITH THE NEXT

WALL LAYER.

- REFER TO DETAIL 5/1A-543.

10. RADIO FRENQUENCY SHEILDING SHALL BE

PROVIDED AND INSTALLED PER

MANUFACTURER'S REQUIREMENTS. INCLUDE

AT WALLS, FLOOR AND DOORS.

INDICATES WALL TYPE CONSTRUCTION. REFER

TO PARTIAL PLANS.

GRAPHIC SCALE: = 1'-0"

1' 06" 2' 3'1'

1"GRAPHIC SCALE: = 1'-0"

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

F

IL

E N

A M

E

1A-540

W A

L L T

Y P

E S

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K L A

H O

M A

M B

A R

N E

T T

K R

IG

G

S

W F

O Y

A M c C

O Y

A P

R

IL

R E

A D

Y T

O A

D V

E R

T

IS

E

A F

L C

M C

F A

C

IL

IT

Y

D E

S

IG

N B

U

IL

D

IN

G

T U

L S

A D

IS

T

R

IC

T T

U L S

A O

K L A

H O

M A

N o n e A

-5 .d w g

W A

G G

R O

U P

SCALE: 1" = 1'-0"

WALL TYPES

GENERAL SHEET NOTES

LEGEND

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

/1 /2

ACOUSTICAL

BLANKET

INSULATION

METAL STUDS AT 16" O.C.,

REFER TO PLANS FOR

WALL

TYPE

LIGHT FIXTURE,

REFER TO

ELECTRICAL

DRAWINGS

CEILING HEIGHT

EL.=109'-0"

SOFFIT HEIGHT

EL.=108'-0"

WALL TILE, REFER

TO FINISH SCHEDULE

3 5/8" METAL

STUDS AT 16" O.C.

5/8" WATER

RESISTANT

GYPSUM BOARD

5/8" CEMENTITIOUS BACKER BOARD

BAFFLE

SUSPENDED ACOUSTICAL

CEILING

CORNER BEAD

SUSPENDED

ACOUSTICAL

CEILING

3 5/8" METAL

STUDS AT 16" O.C.

5/8" GYPSUM

BOARD

CEILING HEIGHT

EL = 109'-0" A.F.F

BOTTOM OF BULKHEAD

EL=108'-6" A.F.F.

SUSPENDED CEILING

HANGER WIRE

SUSPENDED ACOUSTICAL

CEILING

SUSPENDED

ACOUSTICAL

CEILING

CEILING HEIGHT

EL = 109'-0" A.F.F

SUSPENDED CEILING

HANGER WIRE

EXPANSION

JOINT COVER.

COLOR TO

MATCH

CEILING.

4"

EXPANSION JOINT COVER.

COLOR TO MATCH CEILING.

3-5/8" METAL STUDS

CONTINUOUS

EXTEND STUDS TO

STRUCTURE ABOVE

4" 5/8" WATER RESISTANT

GYPSUM BOARD ON 3-5/8"

METAL STUDS @ 16" OC

CEILING HEIGHT

EL.=109'- 5"

5/8" TYPE 'X' GYPSUM BOARD

2-1/2" 25-GAUGE C-H

STUD AT 24" O.C.

1" GYPSUM LINER PANEL

2-1/2" WIDE 24-GAUGE J-RUNNER

ACOUSTICAL SEALANT

REFER TO FLOOR PLANS AND

WALL TYPES FOR SPECIFIC WALL

INFORMATION AND RATINGS

3-5/8" METAL STUD AT 16" O.C.

/8

FIRE TEST NO: WHI 495-PSH-0154/0167

GRAPHIC SCALE: = 1'-0"

1' 06" 2' 3'1'

1"GRAPHIC SCALE: = 1'-0"

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

F

IL

E N

A M

E

1A-560

C E

IL

IN

G D

E T

A

IL

S

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K L A

H O

M A

M B

A R

N E

T T

K R

IG

G

S

W F

O Y

A M c C

O Y

A P

R

IL

R E

A D

Y T

O A

D V

E R

T

IS

E

A F

L C

M C

F A

C

IL

IT

Y

D E

S

IG

N B

U

IL

D

IN

G

T U

L S

A D

IS

T

R

IC

T T

U L S

A O

K L A

H O

M A

N o n e A

-5 .d w g

W A

G G

R O

U P

SCALE: 1" = 1'-0"1A-560

2 SOFFIT DETAIL

SCALE: 1" = 1'-0"1A-560

1 BULKHEAD DETAIL

SCALE: 1" = 1'-0"1A-560

4 ACT EXPANSION JOINT DETAIL

SCALE: 1" = 1'-0"1A-560

3 GYPSUM EXPANSION JOINT DETAIL

SCALE: 1" = 1'-0"1A-560

5 1-HOUR RATED CEILING DETAIL

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

/1 /2

M A

X

METAL STUDS AT 16" O.C.

W/R-19 BATT INSULATION.

GLASS

ABC FIRE

EXTINGUISHER

(10 lb.) (N.I.C.)

ABA COMPLIANT CABINET ASSEMBLY

WITH 2 1/2" ROLLED RETURN TRIM,

MOUNT CENTERLINE OF CABINET AT 48"

A.F.F.

5/8" GYPSUM BOARD,

PAINTED

2 1/2" RETURN

TRIM,

(TYPICAL)

4'-0" A.F.F.

NOTES:

1.

2.

3.

SEMI-RECESSED FIRE EXTINGUISHER CABINET (TO BE ONE HOUR RATED WHEN INSTALLED IN RATED WALLS).

CABINET SIZE TO BE APPROXIMATELY 26 3/4"H x 11 3/4" W. CABINET AND HANDLE SHALL COMPLY WITH ABA REQUIREMENTS. CABINET SHALL BE SIZED TO FIT IN 3 5/8" METAL STUD WALL WITH 5/8" GYPSUM BOARD EACH SIDE AND ACCOMMODATE 10lb FIRE EXTINGUISHER AND BE NON-LOCKING. COORDINATE OPENING SIZE REQUIREMENT WITH CABINET. PROVIDE GLASS AND SIGNAGE.

SEMI-RECESSED

FIRE EXTINGUISHER CABINET - PLAN

FIRE EXTINGUISHER

CABINET - ELEVATION

SURFACE MOUNTED FIRE EXTINGUISHER SHALL BE MOUNTED WITH THE LEADING EDGE AT OR BELOW 27" TO COMPLY WITH ABA REQUIREMENTS.

METAL STUDS AT 16" O.C. WITH

BATT INSULATION.

ABC FIRE

EXTINGUISHER

(10 lb.) (N.I.C.)

5/8" GYPSUM BOARD,

PAINTED

SURFACE MOUNTED

FIRE EXTINGUISHER CABINET - PLAN

ABA COMPLIANT CABINET ASSEMBLY

WITH 2 1/2" ROLLED RETURN TRIM,

MOUNT BOTTOM OF CABINET HANDLE AT

27" A.F.F.

N O

M

IN

A L

N O

M

IN

A L

/2

N O

M

IN

A L

1'-6" NOMINAL

A B

A R

E Q

U

IR

E D

FINISH FLOOR

BUGLE HEAD DRYWALL

SCREW STAGGERED

9" O.C.

1/4" RADIUS

CONTINUOUS EXTRUDED

ALUMINUM RETAINER

CONTOURED FOR

VINYL WALL COVERING

OR PAINT

FEATHERED JOINT

CEMENT

5/8" GYPSUM BOARD

3 5/8" METAL STUDS

WALL TYPES

VARY, REFER

TO FLOOR PLANS

SELF-TAPPING SCREWS

3" x 3" x 72" RESILIENT

CORNER GUARD. MOUNT

ABOVE BASE.

CONTINUOUS RETAINER

SHEET MATERIAL

5/8" GYPSUM BOARD

WALL TYPES

VARY, REFER

TO FLOOR PLANS

4" - 5"

PERIMETER ADAPTOR

STEEL

FLOOR PANEL

PEDESTAL

PERIMETER

PEDESTAL

FASCIA ANGLE SECURED

TO SUBFLOOR WITH

ADHESIVE

CORNERLOCK FASCIA ASSEMBLY

PERIMETER

PEDESTAL

ALL STEEL

FLOOR PANEL

FASCIA

TRIM

ANGLE

PERIMETER

ADAPTER

AND RUBBER

STAIR NOSE

FASCIA

PLATE

COVER WITH

CARPET

CARPET TILE

FASCIA ANGLE SECURED

TO

SUBFLOOR WITH ADHESIVE

CARPET OVER STEEL FASCIA

PANEL

FASCIA TRIM ANGLE

SITE CUT TO SIZE CONCORE

DIAGONAL BRACE

FASTENED TO PANEL

BOTTOM AND TO

SUBFLOOR (WHERE PANEL

AT FASCIA IS NOT

SECURED)

PERIMETER

PEDESTAL

STRINGER CUT BACK ON

SITE TO SUIT PERIMETER

DIMENSIONS6

5'-0"

CARPET TILE

EXISTING CONCRETE FLOOR SLAB

MOISTURE BARRIER

ULTRA RADIANT R-FOIL TO EXTEND 30"

BEYOND FLOOR INFILL

FLOORING MATERIAL APPLIED

OVER R-FOIL/SHEET METAL

4'-0" ROLLED GALVANIZED SHEET METAL

POWER FASTENED TO FLOOR SLAB TO

PROTECT R-FOIL

NEW CONCRETE FLOOR SLAB

2' - 6"

OVERLAP

NOTES:

PROVIDE WOOD BLOCKING FOR TACKBOARD ATTACHMENT.1.

FINISHED WALL

1 1/4" ALUMINUM

FRAME

1/8" NATURAL

CORK

3'-0" A.F.F.

1 1/4" ALUMINUM

FRAME

NOTES:

PROVIDE WOOD BLOCKING FOR MARKERBOARD ATTACHMENT.1.

FINISHED WALL

ANCHOR AS

RECOMMENDED

BY

MANUFACTURER

(TYPICAL)

MARKER TRAY

1/4" LIQUID MARKER

BOARD

3'-0" A.F.F.

GRAPHIC SCALE: = 1'-0"

1' 06" 2' 3'1'

1"GRAPHIC SCALE: = 1'-0"

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

F

IL

E N

A M

E

1A-580

M

IS

C E

L L A

N E

O U

S D

E T

A

IL

S

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K L A

H O

M A

M B

A R

N E

T T

K R

IG

G

S

W F

O Y

A M c C

O Y

A P

R

IL

R E

A D

Y T

O A

D V

E R

T

IS

E

A F

L C

M C

F A

C

IL

IT

Y

D E

S

IG

N B

U

IL

D

IN

G

T U

L S

A D

IS

T

R

IC

T T

U L S

A O

K L A

H O

M A

N o n e A

-5 .d w g

W A

G G

R O

U P

SCALE: 1" = 1'-0"1A-580

1 FIRE EXTINGUISHER CABINET DETAILS

SCALE: 1" = 1'-0"1A-580

COMBINATION WATER FOUNTAIN / BOTTLE

FILLING STATION DETAIL

SCALE: NTS1A-580

CORNER GUARD DETAIL5

SCALE: NTS1A-580

CORNER GUARD DETAIL6

SCALE: NTS1A-580

RAISED ACCESS FLOOR DETAIL9

SCALE: NTS1A-580

RAISED ACCESS FLOOR DETAIL8

SCALE: NTS1A-580

RAISED FLOOR STEP DETAIL7

SCALE: NTS1A-580

RF SHIELDING FLOOR DETAIL10

SCALE: 1" = 1'-0"1A-580

2 TACKBOARD DETAIL

SCALE: 1" = 1'-0"1A-580

3 MARKERBOARD DETAIL

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

/1 /2

1. ALL FINISHES ARE SPECIFIED USING PLAN NORTH.

2. REFER TO SHEET 1A-611 FOR FINISH KEYS AND FINISH

NOTES.

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

F

IL

E N

A M

E

1A-610

F

IN

IS

H

S C

H E

D U

L E

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K L A

H O

M A

W K

IR

K

P A

T R

IC

K

K R

IG

G

S

W F

O Y

A M c C

O Y

A P

R

IL

R E

A D

Y T

O A

D V

E R

T

IS

E

A F

L C

M C

F A

C

IL

IT

Y

D E

S

IG

N B

U

IL

D

IN

G

T U

L S

A D

IS

T

R

IC

T T

U L S

A O

K L A

H O

M A

N o n e A

-6 .d w g

W A

G G

R O

U P

ROOM FINISH SCHEDULE

ROOM FLOOR WALL FINISH CEILING

NOTES & REMARKSNUMBER NAME MAT. BASE PLAN NORTH PLAN EAST PLAN SOUTH PLAN WEST MATL HEIGHT

100 VESTIBULE SEM-1 RB-1 P-3 P-3 P-3 P-3 ACT-1 9' - 0"

101 LOBBY CON-1 RB-1 P-4 P-3 P-3 P-4 ACT-1 9' - 0"

102 STORAGE CON-1 RB-1 P-3 P-3 P-3 P-3 ACT-2 9' - 0"

103 LACTATION CPT-1 RB-1 P-3 P-3 P-3/ DWT-1 P-3 ACT-2 9' - 0"

104 MEN'S PFT-1 PBT-1 PWT-1 PWT-1 PWT-1 PWT-1 GWB-2 9' - 0"

105 WOMEN'S PFT-1 PBT-1 PWT-1 PWT-1 PWT-1 PWT-1 GWB-2 9' - 0"

106 JAN. CON-1 RB-1 P-3/ FRP-1 P-3/ FRP-1 P-3 P-3 GWB-2 9' - 0"

107 CORRIDOR CON-1 RB-1 P-3 P-3 P-3 P-3 ACT-2 9' - 0"

108 MEN'S PFT-1 PBT-1 PWT-1 PWT-1 PWT-1 PWT-1 GWB-2 9' - 0"

109 WOMEN'S PFT-1 PBT-1 PWT-1 PWT-1 PWT-1 PWT-1 GWB-2 9' - 0"

110 STOR. CON-1 RB-1 P-3 P-3 P-3 P-3 ACT-2 9' - 0"

111 BREAKROOM CON-1 RB-1 P-3/ CR-1 P-3/ DWT-1 P-3/ CR-1 P-4/ CR-1 ACT-2 9' - 0"

112 MECHANICAL CON-1 RB-1 P-3 P-3 P-3 P-3 EXP 16' - 0" REFER TO FINISH NOTE #20. PAINT SURFACE MOUNTED EQUIPMENT TO

MATCH WALL COLOR. REFER TO NOTE 21.

113 COMM ESD-1 RB-1 P-3 P-3 P-3 P-3 EXP 16' - 0" REFER TO FINISH NOTE #20.

114 ELECTRICAL CON-1 RB-1 P-3 P-3 P-3 P-3 EXP 16' - 0" REFER TO FINISH NOTE #20. PAINT SURFACE MOUNTED EQUIPMENT TO

MATCH WALL COLOR. REFER TO NOTE 21.

115 TRAINING CPT-1 RB-1 P-3 P-3 P-4 P-3 ACT-2 9' - 0"

116 CORRIDOR CON-1 RB-1 P-3 P-3 P-3 P-3 ACT-2 9' - 0"

117 UNCLASSIFIED WORK AREA CPT-1 RB-1 P-3 P-3 P-3 P-3 ACT-2 9' - 0"

118 IT BUILD ESD-1 RB-1 P-3 P-3 P-3 P-4 EXP 16' - 0" REFER TO FINISH NOTE #20.

119 MAN TRAP CON-1 RB-1 P-3 P-3 P-3 P-3 ACT-2 9' - 0"

120 VISITOR CONTROL CPT-1 RB-1 P-3 P-3 P-3 P-3 ACT-2 9' - 0"

121 SECURITY CPT-1 RB-1 P-3 P-3 P-3 P-3 ACT-2 9' - 0"

122 SERVER ESD-1 RB-1 P-3 P-3 P-3 P-3 EXP 16' - 0" REFER TO FINISH NOTE #20.

123 IT STORAGE CON-1 RB-1 P-3 P-3 P-3 P-3 EXP 16' - 0" REFER TO FINISH NOTE #20.

124 GRP DIRECTOR CPT-1 RB-1 P-4 P-3 P-3 P-3 ACT-2 9' - 0"

125 LG SUP CPT-1 RB-1 P-4 P-3 P-3 P-3 ACT-2 9' - 0"

126 SEC SUP CPT-1 RB-1 P-4 P-3 P-3 P-3 ACT-2 9' - 0"

127 ADMIN CPT-1 RB-1 P-3 P-3 P-3 P-3 ACT-1 9' - 0"

128 FM DIRECTOR CPT-1 RB-1 P-3 P-3 P-3 P-4 ACT-2 9' - 0"

129 CONFERENCE CPT-1 RB-1 P-3 P-3 P-3 P-4 ACT-3 9' - 0"

130 PK DIRECTOR CPT-1 RB-1 P-3 P-4 P-3 P-3 ACT-2 9' - 0"

131 DEP DIRECTOR CPT-1 RB-1 P-4 P-3 P-3 P-3 ACT-2 9' - 0"

132 LG SUP CPT-1 RB-1 P-4 P-3 P-3 P-3 ACT-2 9' - 0"

133 IT SUP CPT-1 RB-1 P-3 P-3 P-3 P-3 ACT-2 9' - 0"

134 CORRIDOR CON-1 RB-1 P-3 P-3 P-3 P-3 ACT-2 9' - 0"

135 PK OFFICE CPT-1 RB-1 P-3 P-3 P-4 P-3 ACT-2 9' - 0"

135A SUPER CPT-1 RB-1 P-3 P-4 P-3 P-3 ACT-2 9' - 0"

136 IPT OFFICE CPT-1 RB-1 P-3 P-3 P-3 P-3 ACT-2 9' - 0"

136A SUPER CPT-1 RB-1 P-4 P-3 P-3 P-3 ACT-2 9' - 0"

137 FA/MN CON-1 RB-1 P-3 P-3 P-3 P-3 EXP 9' - 0" REFER TO FINISH NOTE #20.

138 CYBER OFFICE CPT-1 RB-1 P-3 P-3 P-3 P-3 ACT-2 9' - 0"

138A SUPER CPT-1 RB-1 P-4 P-3 P-3 P-3 ACT-2 9' - 0"

139 IPT OFFICE CPT-1 RB-1 P-3 P-3 P-3 P-4 ACT-2 9' - 0"

139A SUPER CPT-1 RB-1 P-4 P-3 P-3 P-3 ACT-2 9' - 0"

141 SUPPORT COPIER CON-1 RB-1 P-3 P-3 P-3 P-3 ACT-2 9' - 0"

142 ELECTRICAL CON-1 RB-1 P-3 P-3 P-3 P-3 EXP 16' - 0" REFER TO FINISH NOTE #20.

143 SOURCE SELECTION ROOM CPT-1 RB-1 P-3 P-4 P-3 P-3 ACT-2 9' - 0"

145 SMALL CONFERENCE CPT-1 RB-1 P-3 P-3 P-4 P-3 ACT-3 9' - 0"

146 VESTIBULE CPT-1 RB-1 P-3 P-3 P-3 P-3 ACT-2 9' - 0"

147 BREAKOUT CPT-1 RB-1 P-3/ CR-1 P-4/ CR-1 P-3/ CR-1 P-3/ CR-1 ACT-3 9' - 0"

148 SMALL CONFERENCE CPT-1 RB-1 P-4/ CR-1 P-3/ CR-1 P-3/ CR-1 P-3/ CR-1 ACT-3 9' - 0"

149 LARGE CONFERENCE CPT-1/RAF-1 RB-1 P-3/ AWP-2 P-3 P-3/ AWP-2 P-4 ACT-3 10' - 0" RAISED AUDITORIUM FLOOR SYSTEM TO HAVE CARPET TILE WITH SLIP

RESISTANT STAIR NOSING.

149A MEDIA CPT-1 RB-1 P-3 P-3 P-3 P-3 ACT-2 9' - 0"

150 VEST CPT-1 RB-1 P-3 P-3 P-3 P-3 ACT-2 9' - 0"

151 OPEN OFFICE 1 CPT-1 RB-1 P-3 P-3 P-3 P-3 ACT-2 9' - 0"

151A SUPER CPT-1 RB-1 P-3 P-3 P-3 P-4 ACT-2 9' - 0"

152 OPEN OFFICE 2 CPT-1 RB-1 P-3 P-3 P-3 P-3 ACT-2 9' - 0"

152A SUPER CPT-1 RB-1 P-3 P-4 P-3 P-3 ACT-2 9' - 0"

153 OPEN OFFICE 3 CPT-1 RB-1 P-3 P-3 P-3 P-3 ACT-2 9' - 0"

153A SUPER CPT-1 RB-1 P-3 P-3 P-3 P-4 ACT-2 9' - 0"

154 OPEN OFFICE 4 CPT-1 RB-1 P-3 P-3 P-3 P-3 ACT-2 9' - 0"

154A SUPER CPT-1 RB-1 P-3 P-4 P-3 P-3 ACT-2 9' - 0"

155 CORRIDOR CON-1 RB-1 P-3 P-3 P-3 P-3 ACT-2 9' - 0"

156 FIRE RISER CON-1 RB-1 P-3 P-3 P-3 P-3 GWB-3 16' - 0"

157 VESTIBULE SEM-1 RB-1 P-3 P-3 P-3 P-3 ACT-2 9' - 0"

FINISH SCHEDULE NOTES

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

/1 /2

1. MANUFACTURERS REFERENCED ARE INTENDED TO

ESTABLISH COLOR, PATTERN, AND FINISH ONLY.

FINISHES LISTED ARE NOT INTENDED TO LIMIT

SELECTIONS FROM OTHER MANUFACTURERS.

SUBSTITUTIONS SHALL BE SUBMITTED ALONG WITH

PRODUCTS ON FINISH SCHEDULE.

2. CEILING COLORS SHALL APPLY TO SURFACES

INCLUDING GRILLES, DIFFUSERS, REGISTERS AND

ACCESS PANELS.

3. EXPOSED STRUCTURE, METAL DECKING TO BE PAINTED

"P-2". REFER TO FINISH NOTE 20.

4. SUSPENDED GYPSUM CEILINGS AND FUR DOWN

("GWB-2" AND "GWB-3") TO BE PAINTED "P-1" AND "P-2"

UNLESS OTHERWISE NOTED.

5. COLUMNS SHALL BE PAINTED ("P-3") UNLESS

OTHERWISE NOTED.

6. ALL GROUT SHALL BE EPOXY.

7. USE A "GROUT RELEASE" ON FLOOR TILE TO HELP WITH

CLEAN UP OF GROUT.

8. ALL MAINTENANCE AREA INTERIOR METAL DOORS AND

DOOR FRAMES TO BE PAINTED "P-5"" ALKYD ENAMEL

SATIN FINISH.

9. ALL ADMINISTRATIVE AREA TRIM TO BE PAINTED "P-5"

GLOSS FINISH.

10. ALL INTERIOR SOLID CORE WOOD DOORS TO BE

FACTORY "FINISHED TO MATCH STAIN "STN-1".

11. APPLY ABA COMPLIANT TRANSITION STRIPS AT ALL

FLOOR CHANGES.

12. FLUSH-MOUNTED RESILIENT CORNER GUARDS ("CG-1")

SHALL BE INSTALLED FLOOR-TO-CEILING HEIGHT AT ALL

OUTSIDE CORNERS (INCLUDING COLUMNS), AND SHALL

BE COORDINATED WITH PAINT COLOR OF EACH WALL IN

ADMINISTRATIVE AREAS. REFER TO FINISH KEY.

13. FLUSH-MOUNTED RESILIENT CORNER GUARDS ("CG-2")

SHALL BE INSTALLED FLOOR-TO-CEILING HEIGHT AT ALL

OUTSIDE CORNERS WHERE "PNT-4" IS USED. REFER TO

FINISH KEY.

14. CHAIR RAILS TO BE INSTALLED IN CONFERENCE ROOM

(145 AND 148) AND BREAKOUT ROOM (147) AND BREAK

ROOM (111) AT 32" AFF.

15. INSTALL FIBERGLASS REINFORCED PANEL ("FRP-1") UP

TO 48" A.F.F. ON BOTH SIDES OF THE MOP SINK IN THE

JANITORS CLOSET 106.

16. CUT EDGES OF WALL TILE AT OUTSIDE CORNERS SHALL

BE TRANSITIONED USING SCHLUTER-STYLE TRIM.

17. PORCELAIN FLOOR TILE TO BE INSTALLED WITH A 1/3

OFFSET. USE A MEDIUM BED…