D_Tel11.pdf

PDF 2 MB Posted

Attached to
Construction services for an Aircraft Maintenance Hangar
Solicitation number
W912BU-18-R-0026
Issued by

About this file

This solicitation is for construction services for an Aircraft Maintenance Hangar at Dover Air Force Base, Delaware. The project includes construction of an 84,176 square foot hangar with office spaces, tool rooms, break room, toilet facilities and support spaces. Related site work includes roads, utilities and optional parking areas. The facility requires enhanced commissioning and LEED Silver certification. The firm-fixed price contract value is between $25-100 million with a 610 calendar day performance period. Proposals are due on April 5, 2019. The contract will be awarded using the tradeoff source selection process based on technical and price factors. A site visit is scheduled for March 1, 2019 for interested firms to examine the project location.

Drawings - 11

View the file

Other files

File Type Posted
18R0026_Specs-AM2.pdf PDF
18R0026_Dwgs-AM2.pdf PDF
18-R-0026_DAFB_AMH_Pre-proposal_Site_Visit_Attendance_Roster.pdf PDF
18R0026_Specs-AM1R1.pdf PDF
D_Elec10.pdf PDF
D_Civ2.pdf PDF
D_Structural4.pdf PDF
RFI_Format.pdf PDF
D_Civ3.pdf PDF
D_Int6.pdf PDF
D_Fire7.pdf PDF
D_Arch5.pdf PDF
18R0026-SpecsVol1-RTA.pdf PDF
D_Plum8.pdf PDF
D_Gen1.pdf PDF
D_Mech9.pdf PDF
18R0026-SpecsVol3-RTA.pdf PDF
18R0026-SpecsVol2-RTA.pdf PDF
Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TELECOMMUNICATIONS HORIZONTAL CABLING

SYSTEM DESIGNATION CABLE TYPE CABLE COLOR

DATA CAT 6 U/UTP BLUE

TELECOMMUNICATIONS BACKBONE CABLING

SYSTEM DESIGNATION CABLE TYPE

DATA OPTICAL FIBER 12- STRAND SM

TELECOMMUNICATIONS STANDARDS

TELECOMMUNICATIONS CABLING NOTES

VOICE MULTI-PAIR ISP VOICE GRADE

VOICE CAT 6 U/UTP WHITE

SYMBOL TELECOMMUNICATIONS DESCRIPTION

110 110 PUNCHDOWN BLOCKS, RACK OR WALL MOUNTED AS INDICATED

8P8C 8-PIN, 8-CONDUCTOR

ACS ACCESS CONTROL SYSTEM

AFF ABOVE FINISHED FLOOR

AHJ AUTHORITY HAVING JURISDICTION

AWG AMERICAN WIRE GAUGE

BCO BASE COMMUNICATIONS OFFICER

BCT BONDING CONDUCTOR FOR TELECOMMUNICATIONS

C CONDUIT(S)

CAA CONTROLLED ACCESS AREA

CAT 6 CABLING ETL VERIFIED TO ANSI/TIA-568-C.2 CATEGORY 6

CATV CABLE TELEVISION

CCH CLOSET CONNECTOR HOUSING

CCTV CLOSED-CIRCUIT TELEVISION

CFCI CONTRACTOR FURNISHED CONTRACTOR INSTALLED

CP CONSOLIDATION POINT

DB DIRECT BURIED

DDC DIRECT DIGITAL CONTROL

DIA DIAMETER

DWG DRAWING

ER EXISTING RELOCATED

ETR EXISTING TO REMAIN

EXIST EXISTING

FB FLOOR BOX

FT FEET

GFGI GOVERNMENT FURNISHED GOVERNMENT INSTALLED

GND GROUND

GRS GALVANIZED RIGID STEEL

IAW IN ACCORDANCE WITH

ICT INFORMATION AND COMMUNICATIONS TECHNOLOGY

IDS INTRUSION DETECTION SYSTEM

IN INCHES

LCA LIMITED CONTROL ACCESS

MC MECHANICAL CONTRACTOR

MIN MINIMUM

MTD MOUNTED

NEC NETWORK ENTERPRISE CENTER

NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION

NESC NATIONAL ELECTRICAL SAFETY CODE

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NIC NOT IN CONTRACT

NTS NOT TO SCALE

OEM ORIGINAL EQUIPMENT MANUFACTURER

OFCI OWNER FURNISHED CONTRACTOR INSTALLED

OFOI OWNER FURNISHED OWNER INSTALLED

OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION

PA PUBLIC ADDRESS

PE POLYETHYLENE

PET PROTECTED ENTRANCE TERMINALS

POTS PLAIN OLD TELEPHONE SERVICE (SWITCHED TELEPHONE LINE)

PSI POUNDS PER SQUARE INCH

PTZ PAN / TILT / ZOOM

QTY QUANTITY

RR REMOVE AND RELOCATE

RS RIGID STEEL

RU RACK UNIT

SCH SCHEDULE

STP SHIELDED TWISTED PAIR

TBB TELECOMMUNICATIONS BONDING BACKBONE

TE TELECOMMUNICATIONS ENCLOSURE

TGB TELECOMMUNICATIONS GROUNDING BUSBAR

TMGB TELECOMMUNICATIONS MAIN GROUNDING BUSBAR

TYP TYPICAL

U/G UNDERGROUND

UON UNLESS OTHERWISE NOTED

U/UTP UNSCREENED/UNSHIELDED TWISTED PAIR CABLE

VoIP VOICE OVER INTERNET PROTOCOL

WP WEATHERPROOF

XP EXPLOSION PROOF

TELECOMMUNICATIONS ABBREVIATIONSTELECOMMUNICATIONS GENERAL NOTES

1. THIS IS A STANDARD LEGEND SHEET. NOT ALL SYMBOLS OR ABBREVIATIONS

MAY APPEAR ON DRAWINGS.

2. REFER TO DIVISIONS 26, 27, 28 AND 33 SPECIFICATIONS FOR

TELECOMMUNICATION SYSTEM ITEMS.

3. MOUNTING DEVICES AND EQUIPMENT PER SPECIFICATIONS UNLESS

OTHERWISE NOTED.

4. MOUNTING HEIGHTS, UNLESS OTHERWISE NOTED, ARE TO CENTER LINE OF

DEVICE.

5. THE CONTRACTOR SHALL DETERMINE THE EXACT ROUTING OF RACEWAYS.

6. THE CONTRACTOR SHALL COORDINATE ALL RACEWAY PENETRATIONS AND

PROVIDE FIREPROOFING AS APPLICABLE.

7. THE MAXIMUM PERMANENT HORIZONTAL LINK DISTANCE SHALL NOT EXCEED

295' AND THE MAXIMUM HORIZONTAL CHANNEL (LINK PLUS WORKSTATION

CABLES AND PATCH CORDS) SHALL BE 328'.

8. ALL HORIZONTAL VOICE AND DATA CABLING SHALL BE CATEGORY-6

INSTALLED IN A MINIMUM 1" CONDUIT UNLESS NOTED OTHERWISE FROM

TELECOMM OUTLET LOCATIONS TO THE CABLE TRAY.

9. ALL HORIZONTAL AND BACKBONE CABLING SHALL BE PLENUM RATED WITH

THE EXCEPTION OF CABLING INSTALLED IN UNDERGROUND CONDUITS. SEE

NOTE 21 FOR CABLES INSTALLED IN UNDERGROUND CONDUITS.

10. CATEGORY-6 CABLING SHALL BE TERMINATED ON 8-PIN, 8-CONDUCTOR (RJ-

45) CONNECTORS USING PIN/PAIR ASSIGNMENTS IN ACCORDANCE WITH T568B

PIN-OUT SEQUENCE.

11. CATEGORY-6 JACKS SHALL BE THE SAME COLOR AS CORRESPONDING

HORIZONTAL VOICE AND DATA CABLING. CATEGORY-6 JACKS SHALL BE THE

SAME MANUFACTURER AS THE PATCH PANELS.

12. PROVIDE CATEGORY-6, 8-PIN, 8-CONDUCTOR MODULAR TO 8-PIN, 8-

CONDUCTOR MODULAR, PATCH CABLES IN QUANTITIES AND LENGTHS SUCH

THAT ALL WORKSTATION CABLES ARE CONNECTED.

13. OPTICAL FIBER CABLES SHALL BE TERMINATED WITH DUPLEX LC-TYPE

CONNECTORS.

14. THE USE OF J-HOOKS SHALL BE LIMITED. WHEN USED, J-HOOKS SHALL BE

CATEGORY-6 RATED AND SPACES AT INTERVALS NOT TO EXCEED 5'. J-HOOKS

SHALL NOT EXCEED 24 CABLES OR 50% FILL, WHICHEVER IS LESS. WHEN J-

HOOKS ARE USED TO SPAN FROM CONDUIT STUB UPS TO CABLE TRAY, A

BONDING BUSHING SHALL BE INSTALLED ON THE CONDUIT STUB UPS AND A

MINIMUM #6 AWG GROUND CONDUCTOR SHALL BE INSTALLED FROM THE

BONDING BUSHING TO THE CABLE TRAY, EFFECTIVELY BONDING THE

METALLIC RACEWAYS TOGETHER.

15. ALL TELECOMMUNICATIONS RACKS AND SUPPORTING STRUCTURES (CABLE

TRAYS, LADDER RACKS, CONDUITS, AND BASKETS) WITHIN A TR MUST BE

BONDED TO THE TR SIGNAL GROUND RING OR BUS BAR (TGB OR TMGB) AS

DEFINED IN ANSI/TIA-569-C AND IN ANSI/TIA-607-B.

16. CABLE TRAY SHALL BE WALL MOUNTED (PREFERABLE) OR TRAPEZE

MOUNTED. CENTER HUNG CABLE TRAY IS NOT ALLOWED. CABLE TRAY SHALL

NOT BE USED TO SUPPORT OTHER ITEMS, CONDUIT, CABLE TRAY, PIPING OF

UTILITIES. CABLE TRAY SUPPORTS SHALL BE PER NEMA STANDARDS

PUBLICATION VE 2 - METAL CABLE TRAY INSTALLATION GUIDELINES.

17. PROVIDE ACCESS PANELS IN NON LAY-IN CEILINGS SUCH THAT NO POINT IN

THE CABLE TRAY SYSTEM IS MORE THAN 20' FROM AN ACCESS POINT.

18. PROVIDE A MINIMUM OF 12" OF CLEARANCE ABOVE THE TOP OF CABLE TRAYS

AND A MINIMUM OF 3" CLEARANCE BELOW CABLE TRAYS.

19. COMPLY WITH ANSI/TIA-569-C TELECOMMUNICATION PATHWAYS AND SPACES.

20. USE ONLY COPPER CONDUCTORS FOR GROUND CONNECTIONS. THE USE OF

ALUMINUM CONDUCTORS IS NOT ALLOWED.

21. PROVIDE CABLE INSTALLED IN UNDERGROUND CONDUITS LISTED FOR USE IN

WET LOCATIONS. PLENUM RATED CABLE SHALL NOT BE INSTALLED IN ANY

UNDERGROUND CONDUIT.

22. LABEL ALL CABLE TERMINATIONS AND BOTH ENDS OF ALL CABLES IN

ACCORDANCE WITH UFC 3-580-01 AND ANSI/TIA-606-B.

23. PROVIDE AS-BUILT DOCUMENTATION INCLUDING COMPLETE TEST RESULT

REPORTS, FLOOR PLANS SHOWING USER WORKSTATIONS WITH CABLING

LABELING, AND BACKBONE CABLE SCHEMATIC AND LABELING IN AN

ELECTRONIC FORMAT (PDF) OR OTHER APPROVED FORMAT AND A PRINTED

HARDCOPY. TEST RESULTS SHALL BE SUPPLIED ELECTRONICALLY TO THE

PROJECT RCDD AND CORPS PROJECT ENGINEER/ARCHITECT IN THE TEST

PROGRAM NATIVE FORMAT.

24. ANY MOTOR, TRANSFORMER, OR OTHER ELECTRICAL DEVICE GREATER THAN

5 KVA SHALL HAVE A MINIMUM OF A 4' BUFFER FROM ANY WALL OF THE EF,

TER, OR TR(S).

25. THE PUBLIC ADDRESS (PA) SYSTEM, WITH COVERAGE TO ALL INTERIOR AREAS

OF THE FACILITY, SHALL INTERFACE WITH THE TELEPHONE SYSTEM SUCH

THAT THE TELEPHONE SYSTEM PROVIDES ACCESS TO THE PA SYSTEM. ALL

PA SPEAKERS SHALL BE WEATHER PROOF IN ACCORDANCE WITH (I.A.W.) UFC

4-211-01 3-6.19.5.1. THE PA SYSTEM SHALL PROVIDE MASS NOTIFICATION

FUNCTION THROUGHOUT THE SUPPORT AREAS AND HANGAR BAY IN I.A.W.

NFPA 72, UFC 4-021-01, UFC 4-021-01, UFC 4-211-01, AND UFC 3-600-01 C1. THE

MASS NOTIFICATION SYSTEM ANNOUNCEMENTS SHALL TAKE PRIORITY OVER

ALL OTHER AUDIBLE ANNOUNCEMENTS OF THE SYSTEM INCLUDING THE

OUTPUT OF THE FIRE ALARM SYSTEM IN A NORMAL OR ALARM STATE. WHEN A

MASS NOTIFICATION ANNOUNCEMENT IS ACTIVATED DURING A FIRE ALARM,

ALL FIRE ALARM SYSTEM FUNCTIONS SHALL CONTINUE IN AN ALARM STATE

EXCEPT FOR THE OUTPUT SIGNALS OF THE FIRE ALARM AUDIBLE AND VISUAL

NOTIFICATION APPLIANCES.

26. EXISTING CONDITIONS AND DEMOLITIONS ARE SHOWN IN THE CIVIL V-SERIES

DRAWINGS.

27. METALLIC TELECOMMUNICATIONS CABLE TRAY RACEWAYS SHOULD BE MADE

ELECTRICALLY CONTINUOUS TO ENSURE PROPER GROUNDING (EARTHING) OF

ALL METALLIC PARTS AND UNITS TO MINIMIZE THE ACCUMULATION OF

VOLTAGES. A MINIMUM OF A 6 AWG INSULATED, STRANDED COPPER, BONDING

CONDUCTOR SHALL BE INSTALLED BETWEEN THE METALIC

TELECOMMUNICATIONS CABLE TRAY TRANSITIONING TO PVC CONDUIT

RACEWAY EFFECTIVELY BONDING THE METALLIC RACEWAYS TOGETHER.

ANSI/TIA 607-C STANDARD PROVIDES ADDITIONAL GUIDANCE FOR SPECIFIC

BONDING CONDUCTOR SIZE VS LENGTH.

COORDINATE ALL CABLE COLORS WITH AHJ BEFORE PURCHASE.

TELECOMMUNICATIONS INSTALLATION SHALL COMPLY WITH THE MOST

CURRENT VERSION OF THE FOLLOWING STANDARDS:

ANSI/TIA-568-C.2, 2009 - BALANCED TWISTED-PAIR TELECOMMUNICATIONS

CABLING AND COMPONENTS STANDARD

ANSI/TIA-568-C.3, 2008 - OPTICAL FIBER CABLING COMPONENTS STANDARD

ANSI/TIA-568-C.4, 2011 - BROADBAND COAXIAL CABLING AND COMPONENTS

STANDARD

ANSI/TIA-568-D.0, 2015 - GENERIC TELECOMMUNICATIONS CABLING FOR

CUSTOMER PREMISES

ANSI/TIA-568-D.1, 2015 - COMMERCIAL BUILDING TELECOMMUNICATIONS

CABLING STANDARD

ANSI/TIA-569-D, 2015 - TELECOMMUNICATIONS PATHWAYS AND SPACES

ANSI/TIA/EIA-598-C - OPTICAL FIBER CABLE COLOR CODING.

ANSI/TIA-606-B, 2012 - ADMINISTRATION STANDARD FOR COMMERCIAL

TELECOMMUNICATIONS INFRASTRUCTURE

ANSI/TIA-607-B, 2011 - COMMERCIAL BUILDING GROUNDING (EARTHING) AND

BONDING REQUIREMENTS FOR TELECOMMUNICATIONS

ANSI/TIA-758-B, 2012 - CUSTOMER-OWNED OUTSIDE PLANT

TELECOMMUNICATIONS INFRASTRUCTURE STANDARD

ANSI/TIA-1152, 2009 - REQUIREMENTS FOR FIELD TEST INSTRUMENTS AND

MEASUREMENTS FOR BALANCED TWISTED-PAIR CABLING

TIA-526-7 (OFSTP-7)-2002+A1:2008 - MEASUREMENT OF OPTICAL POWER LOSS OF

INSTALLED SINGLE-MODE FIBER CABLE PLANT

TIA-526-14-B-2010 (OFSTP-14) - OPTICAL POWER LOSS MEASUREMENTS OF

INSTALLED MULTIMODE FIBER CABLE PLANT

TIA-758 - CUSTOMER-OWNED OUTSIDE PLANT TELECOMMUNICATIONS

INFRASTRUCTURE

TSB-162-A - TIA SYSTEMS BULLETIN TELECOMMUNICATIONS CABLING

GUIDELINES FOR WIRELESS ACCESS POINTS

IEC/TR 61602 ED. 1.0 B:1996 27-JUN-1996 CONNECTORS USED IN THE FIELD OF

AUDIO, VIDEO AND AUDIOVISUAL ENGINEERING

IEC 61883-1 ED. 3.0 EN:2008 07-FEB-2008 CONSUMER AUDIO/VIDEO EQUIPMENT -

DIGITAL INTERFACE - PART 1: GENERAL

IEC 61883-6 ED. 2.0 EN:2005 28-OCT-2005 CONSUMER AUDIO/VIDEO EQUIPMENT -

DIGITAL INTERFACE - PART 6: AUDIO AND MUSIC DATA TRANSMISSION

PROTOCOL

IEC 61938 ED. 1.0 B:1996 05-DEC-1996 AUDIO, VIDEO AND AUDIOVISUAL SYSTEMS

- INTERCONNECTIONS AND MATCHING VALUES – PREFERRED MATCHING

VALUES OF ANALOGUE SIGNALS

IEC 62075 ED. 1.0 B:2008 15-JAN-2008 AUDIO/VIDEO, INFORMATION AND

COMMUNICATION TECHNOLOGY EQUIPMENT – ENVIRONMENTALLY CONSCIOUS

DESIGN

IEC 62087-BD ED. 2.0 EN:2008 15-OCT-2008 METHODS OF MEASUREMENT FOR

THE POWER CONSUMPTION OF AUDIO, VIDEO AND RELATED EQUIPMENT

UFC-3-580-01 CA - TELECOMMUNICATIONS INTERIOR INFRASTRUCTURE

PLANNING AND DESIGN

UFGS 27.10.00 - BUILDING TELECOMMUNICATIONS CABLING SYSTEM

MIL-HDBK-419A – GROUNDING, BONDING, AND SHIELDING FOR ELECTRONIC

EQUIPMENT AND FACILITIES

MIL-HDBK-1012/3 - TELECOMMUNICATIONS PREMISES DISTRIBUTION PLANNING,

DESIGN, AND ESTIMATING

NFPA 262 - STANDARD METHOD OF TEST FOR FLAME TRAVEL AND SMOKE OF

WIRES AND CABLES FOR USE IN AIR-HANDLING SPACES

NFPA 70 - NATIONAL ELECTRICAL CODE (NEC)

NFPA 75 - STANDARD FOR THE PROTECTION OF INFORMATION TECHNOLOGY

EQUIPMENT

NFPA 76 - STANDARD FOR THE FIRE PROTECTION OF TELECOMMUNICATIONS

FACILITIES

NFPA 780 - STANDARD FOR THE INSTALLATION OF LIGHTNING PROTECTION

SYSTEMS

AR 380-5 - DEPARTMENT OF THE ARMY INFORMATION SECURITY PROGRAM

AMERICANS WITH DISABILITIES ACT AND ARCHITECTURAL BARRIERS ACT

ACCESSIBILITY GUIDELINES (UFAS/ADAAG), 2011

BICSI - BUILDING INDUSTRIES CONSULTING SERVICES INTERNATIONAL (TDMM),

13TH ED., 2014, TELECOMMUNICATIONS DISTRIBUTION METHODS MANUAL 13TH

EDITION.

TERMINATIONS SHALL BE PERFORMED USING PIN/PAIR ASSIGNMENTS IN

ACCORDANCE WITH THE T568B PIN-OUT SEQUENCE USING 8-PIN 8

CONDUCTOR (8P8C) RJ45 TYPE CONNECTORS RATED FOR THE CATEGORY OF

THE INSTALLED CABLE; COLOR SHALL MATCH THE U/UTP OUTER JACKET.

TELECOMMUNICATIONS OUTLETS, 8P8C RJ45 TYPE CONNECTOR

· U/UTP CABLES FOR DATA SHALL HAVE A BLUE OUTER JACKET

· U/UTP CABLES FOR VOICE SHALL HAVE A WHITE OUTER JACKET

CATV OUTLET WITH ONE RG-6 COAXIAL CABLE AND ONE F-TYPE

CONNECTOR, MOUNTED AT 72" AFF

1 STANDARD DUPLEX ICT OUTLET WITH THREE (3) CATEGORY-6

U/UTP CABLE, TWO (2) LABELED DATA AND ONE (1) LABELED

VOICE - CENTER OF OUTLET MOUNTED AT 18" AFF

X = DENOTES (MUTOA) MULTI-USER TELECOMMUNICATIONS

OUTLET ASSEMBLY WHERE (X) DEPICTS THE NUMBER OF

DUPLEX OUTLET CONNECTOR AGGREGATE OF TWO (2)

LABELED DATA AND ONE (1) LABELED VOICE

W

TV

VOICE-ONLY OUTLET - ONE OUTLET CONNECTOR IN A SINGLE

GANG OUTLET FACEPLATE WITH MOUNTING LUGS - MOUNTED AT

57" AFF; WP DESIGNATES "WEATHERPROOF" FOR OUTSIDE

BUILDING ENTRANCES

APPLICABLE TO ALL OUTLETS LISTED BELOW:

X

WP

CATV BROADBAND INDOOR DISTRIBUTION AMPLIFIER

CATV SYMBOLS:

8-WAY SPLITTER

TERMINATION

CONTINUANCE

1 DATA, DIRECT DIGITAL CONTROL (DDC) SYSTEM IT OUTLET,

CENTER OF OUTLET MOUNTED AT 18” AFF

DDC

SYMBOL TELECOMMUNICATIONS DESCRIPTION

WAP WIRELESS ACCESS POINT OUTLET (2 CATEGORY-6 U/UTP

OUTLETS), LOCATED 12" ABOVE DROPPED CEILING

PA

GROUNDING BUSBAR, TMGB OR TGB AS INDICATED ON PLANS

CABLE TRAY, SIZE AS INDICATED ON PLANS. WELDED WIRE TYPE

FOR DISTRIBUTION OF CABLING OUTSIDE OF TELECOMMUNICATION

ROOMS AND LADDER TYPE CABLE RUNWAY WITHIN

TELECOMMUNICATION ROOMS

WEATHERPROOF CEILING MOUNTED PA SYSTEM SPEAKER

19" TELECOMMUNICATIONS EQUIPMENT RACK

VERTICAL UPWARD CONDUIT FROM UNDERGROUND OSP

OTHER SYMBOLS:

HORIZONTAL CONDUIT RUN FROM TELECOMMUNICATION

ROOMS TO RESPECTIVE AREAS AS INDICATED ON PLANS

CRASH PHONE - ONE OUTLET CONNECTOR IN A SINGLE GANG

OUTLET FACEPLATE WITH MOUNTING LUGS - MOUNTED AT 57" AFF;

EP DESIGNATES DEDICATED EMERGENCY WALL MOUNTED PRIVATE

LINE TELEPHONE PROVISIONED FOR AUTOMATIC RING-DOWN TO

THE FIRE DEPARTMENT. LOCATION AND LOGISTICS SHALL BE

COORDINATED WITH THE FIRE DEPARTMENT.

EP

PA WEATHERPROOF WALL MOUNTED PA SYSTEM HORN SPEAKER

MOUNTED AT 15'0" AFF.

1 STANDARD TRIPLEX ICT OUTLET WITH FOUR (4) CATEGORY-6

U/UTP CABLE, THREE (3) LABELED DATA AND ONE (1) LABELED

VOICE - CENTER OF OUTLET MOUNTED AT 18" AFF

X = DENOTES (MUTOA) MULTI-USER TELECOMMUNICATIONS

OUTLET ASSEMBLY WHERE (X) DEPICTS THE NUMBER OF

DUPLEX OUTLET CONNECTOR AGGREGATE OF THREE (3)

LABELED DATA AND ONE (1) LABELED VOICE

TXT

HDMI CONNECTOR

AV

SITE TELECOMMUNICATIONS

Cux EXISTING COMMUNICATION UNDERGOUND CONDUITS TO REMAIN

COMMUNICATIONS MANHOLE - CMH

Cu NEW DIRECT BURIED PVC SCHEDULE 40 CONDUITS

COMMUNICATIONS HANDHOLE - CHH

EXISTING COMMUNICATION UNDERGROUND CONDUITS TO BE DEMOLISHEDCux

SYMBOL

C

CM

1 2 3 4 5

A

B

C

D

PLATE REFERENCE

NUMBER

SHEET OF

P L

O T

D A

T E

P

L O

T S

C A

L E

S U

B M

IT

T

E D

B Y

D W

N B

Y

D E

S

IG

N E

D B

Y

C K

D B

Y

D A

T E

S

IZ

E E

F

IL

E N

A M

E

"X

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

US ARMY CORPS

OF ENGINEERS

PHILADELPHIA

DISTRICT

D O

V E

R A

IR

F

O R

C E

B A

S E

A

IR

C R

A F

T M

A

IN

T E

N A

N C

E F

A C

IL

IT

Y

A S

N O

T E

D

-0

-0

W

B U

- 1 -R

-0

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S

1 2 3 4 5

/1

/2

:0

:2

P M

T-001

T E

L E

C O

M M

U N

IC

A

T

IO

N S

N

O T

E S

, S Y

M B

O L

S A

N D

A B

B R

E V

IA

T

IO

N

S

D K

B R

M S

M V

R T

A

D

E C

D

E C

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

A

B

S c

922 W WWE S

TT T TTTJC T S

c c

S

S c

SS

J C TGEN

DN

VAN

TS101

TS102

CM

CMCux Cux

Cux Cux

C u

C u

C

Cu

Cu

Cu

Cu Cu

TS101T-502

Cu

CM

C u

C uCM

Cux

Cux

Cu Cu

Cu Cu

Cu Cu

Cu Cu

C u

C u

C u

C u

C u

C u

C u

C u

C

C ux

Cux

MH-913-2 Cu x

Cu x

Cux Cux

(1) 4" PVC

(1) 4" PVC

(1) 4" PVC

Cux Cux Cux

(1) 4" PVC

HH-14

(1) 4" PVC

(2) 4" PVC

60SM, B711-B910

6SM, 910-C2

HH-105

(2) 4" PVC

6PR, 22AWG

36SM FIBER

918-711

(2) 4" PVC

60SM, B77-910

6SM, 910-C2

AIP COPPER

(2) 4" PVC

(2) 4" PVC

Cu

Cu

Cu

Cux

PNN

1 2 3 4 5

A

B

C

D

PLATE REFERENCE

NUMBER

SHEET OF

P L

O T

D A

T E

P

L O

T S

C A

L E

S U

B M

IT

T

E D

B Y

D W

N B

Y

D E

S

IG

N E

D B

Y

C K

D B

Y

D A

T E

S

IZ

E E

F

IL

E N

A M

E

"X

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

US ARMY CORPS

OF ENGINEERS

PHILADELPHIA

DISTRICT

D O

V E

R A

IR

F

O R

C E

B A

S E

A

IR

C R

A F

T M

A

IN

T E

N A

N C

E F

A C

IL

IT

Y

A S

N O

T E

D

-0

-0

W

B U

- 1 -R

-0

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S

1 2 3 4 5

/1

/2

:0

:5

P M

TS101

T E

L E

C O

M M

U N

IC

A

T

IO

N S

S

IT

E

U T

IL

IT

Y P

L A

N

D K

B L

A K

M V

R T

A

D

E C

D

E C

KEY PLAN

SCALE:

10'-0" 20'-0" 40'-0"

0'-1" = 20'-0"

GENERAL NOTES

1. SEE DWG T-001 FOR TELECOMMUNICATIONS

NOTES, SYMBOLS, AND ABBREVIATIONS.

2. COMMUNICATIONS MANHOLES HAVE INTERIOR

DIMENSIONS OF 4’ X 4’ X4’ AND NEED TO MATCH

THE SPECIFICATIONS OF THOSE INSTALLED ON

THE BASE. THE APPROVED COMMUNICATIONS

MANHOLES ARE EQUIPPED WITH FOUR (4) “PAI”

MOLDED PULLING IRONS, A 12” DIAMETER X 4”

DEEP SUMP, AND ONE (1) GROUND ROD

KNOCKOUT. THE TOP HAS A 30” ACCESS OPENING.

THEY MUST HAVE THE LOCK DOWN/LOCK DRY

MECHANISM KEYED THE SAME AS ALL

COMMUNICATIONS MANHOLES INSTALLED ON THE

BASE. THE BASE COMMUNICATIONS OFFICER’S

OFFICE (BCO) CAN PROVIDE THE LOCKS FOR THE

LOCK DOWN/LOCK DRY MECHANISMS. THE

MECHANISMS THEMSELVES ARE CONTRACTOR

FURNISHED AND CONTRACTOR INSTALLED.

3. COMMUNICATIONS HANDHOLES ARE 2’ X 3’,

COMPOSITE, WITH NON-LOCKING LIDS.

4. PLEASE COORDINATE WITH THE BCO.

5. THREE (3) CATEGORY-6 OUTSIDE PLANT RATED

U/UTP CABLES INSTALLED INTO THE 3" CONDUIT

TO THE TRANSFORMER PAD FOR DDC. EACH

PASSING THROUGH A CATEGORY-6 DATA LINE

NETWORK SURGE PROTECTOR MODULE

LOCATED IN TER 100 PRIOR TO THE NETWORK

SWITCH. TERMINATE EACH U/UTP CABLE ONTO AN

8P8C RJ45-TYPE JACK, RATED FOR OUTDOOR

INSTALLATION, INSTALLED INTO A NEMA-4X

OUTLET ENCLOSURE AT THE TRANSFORMER PAD.

COORDINATE WITH ELECTRICAL.

LEGEND

Cux

EXISTING COMMUNICATION UNDERGOUND

CONDUITS TO REMAIN

COMMUNICATIONS MANHOLE - CMHCM

Cu NEW DIRECT BURIED PVC SCHEDULE 40

CONDUITS

COMMUNICATIONS HANDHOLE - CHHC

KEYNOTES

1. PROVIDE FOUR (4) 4-INCH PVC SCHEDULE 40

CONDUITS. THREE (3) CONDUIT SHALL INCLUDE

THREE (3) 3-INCH 3-CELL FABRIC MESH

INNERDUCT TOTALING NINE INNNERDUCTS PER

CONDUIT. ONE (1) CONDUIT SHALL BE DEDICATED

FOR ONE (1) 24-STRAND SINGLE MODE FIBER

OPTICAL CABLE. ONE (1) OPEN CONDUIT (NO

INNERDUCT) SHALL BE DEDICATED FOR ONE (1)

100-PAIR OSP UTP COPPER CABLE. TWO (2)

CONDUIT (WITH INNERDUCT) SHALL BE

DEDICATED FOR SPARES.

2. EXISTING TO REMAIN.

3. ABANDONED IN PLACE.

4. ONE (1) 3" CONDUIT INSTALLED BETWEEN TER

100 TO THE TRANSFORMER PAD LOCATED AT

THE SOUTHWEST CORNER OF THE HANGAR

BUILDING.

EXISTING COMMUNICATION UNDERGROUND

CONDUITS TO BE DEMOLISHED

Cux

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

A

B

S c

922 W WWE S

TT T TTTJC T S

c c

S

S c

SS

J C TGEN

DN

VAN

C u

C u

C u

C u

C u

C u

C u

C u

CuCu

CuCu

Cu Cu

Cu Cu

Cu Cu

Cu Cu

Cu Cu

CM Cu Cu

C ux

C ux

C ux

C u

CM

C u

CM

CM

C u

C u

C u

C u

C u

C u

CM C

C ux

C ux

C ux

C ux

C ux

C ux

C u

C u

C u

C u

C ux

DIRECT BURIED

COPPER

HH-26

(1) 4" PVC

(1) 4" PVC

(4) 4" PVC

(4) 4" PVC

MH-91060SM, B910-877

6SM, B910-CAMERA2

36SM,

B639-B910

CM

CM

(1) 4" PVC W/ MAXCEL

BLOWN FIBER FOR

CAMERAS AT MUNITIONS

C ux

C ux

C ux

Cux

Cux Cux

Cux

Cux

36SM,

B639-B910

36SM,

B639-B910

60SM, B910-877

6SM, B910-CAMERA2

60SM, B910-877

6SM, B910-CAMERA2

60SM, B910-877

6SM, B910-CAMERA2

(2) 4" PVC

(2) 4" PVC

AIP COPPER

T

Cu

Cu

TS101

TS102

PNN

1 2 3 4 5

A

B

C

D

PLATE REFERENCE

NUMBER

SHEET OF

P L

O T

D A

T E

P

L O

T S

C A

L E

S U

B M

IT

T

E D

B Y

D W

N B

Y

D E

S

IG

N E

D B

Y

C K

D B

Y

D A

T E

S

IZ

E E

F

IL

E N

A M

E

"X

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

US ARMY CORPS

OF ENGINEERS

PHILADELPHIA

DISTRICT

D O

V E

R A

IR

F

O R

C E

B A

S E

A

IR

C R

A F

T M

A

IN

T E

N A

N C

E F

A C

IL

IT

Y

A S

N O

T E

D

-0

-0

W

B U

- 1 -R

-0

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S

1 2 3 4 5

/1

/2

:0

:0

P M

TS102

T E

L E

C O

M M

U N

IC

A

T

IO

N S

S

IT

E

U T

IL

IT

Y P

L A

N

D K

B L

A K

M V

R T

A

D

E C

D

E C

KEY PLAN

SCALE:

10'-0" 20'-0" 40'-0"

0'-1" = 20'-0"

GENERAL NOTES

1. SEE DWG T-001 FOR TELECOMMUNICATIONS

NOTES, SYMBOLS, AND ABBREVIATIONS.

2. COMMUNICATIONS MANHOLES HAVE INTERIOR

DIMENSIONS OF 4’ X 4’ X4’ AND NEED TO MATCH

THE SPECIFICATIONS OF THOSE INSTALLED ON

THE BASE. THE APPROVED COMMUNICATIONS

MANHOLES ARE EQUIPPED WITH FOUR (4) “PAI”

MOLDED PULLING IRONS, A 12” DIAMETER X 4”

DEEP SUMP, AND ONE (1) GROUND ROD

KNOCKOUT. THE TOP HAS A 30” ACCESS OPENING.

THEY MUST HAVE THE LOCK DOWN/LOCK DRY

MECHANISM KEYED THE SAME AS ALL

COMMUNICATIONS MANHOLES INSTALLED ON THE

BASE. THE BASE COMMUNICATIONS OFFICER’S

OFFICE (BCO) CAN PROVIDE THE LOCKS FOR THE

LOCK DOWN/LOCK DRY MECHANISMS. THE

MECHANISMS THEMSELVES ARE CONTRACTOR

FURNISHED AND CONTRACTOR INSTALLED.

3. COMMUNICATIONS HANDHOLES ARE 2’ X 3’,

COMPOSITE, WITH NON-LOCKING LIDS.

4. PLEASE COORDINATE WITH THE BCO.

5. THREE (3) CATEGORY-6 OUTSIDE PLANT RATED

U/UTP CABLES INSTALLED INTO THE 3" CONDUIT

TO THE TRANSFORMER PAD FOR DDC. EACH

PASSING THROUGH A CATEGORY-6 DATA LINE

NETWORK SURGE PROTECTOR MODULE

LOCATED IN TER 100 PRIOR TO THE NETWORK

SWITCH. TERMINATE EACH U/UTP CABLE ONTO AN

8P8C RJ45-TYPE JACK, RATED FOR OUTDOOR

INSTALLATION, INSTALLED INTO A NEMA-4X

OUTLET ENCLOSURE AT THE TRANSFORMER PAD.

COORDINATE WITH ELECTRICAL.

LEGEND

Cux

EXISTING COMMUNICATION UNDERGOUND

CONDUITS TO REMAIN

COMMUNICATIONS MANHOLE - CMHCM

Cu NEW DIRECT BURIED PVC SCHEDULE 40

CONDUITS

COMMUNICATIONS HANDHOLE - CHHC

KEYNOTES

1. PROVIDE FOUR (4) 4-INCH PVC SCHEDULE 40

CONDUITS. THREE (3) CONDUIT SHALL INCLUDE

THREE (3) 3-INCH 3-CELL FABRIC MESH

INNERDUCT TOTALING NINE INNNERDUCTS PER

CONDUIT. ONE (1) CONDUIT SHALL BE DEDICATED

FOR ONE (1) 24-STRAND SINGLE MODE FIBER

OPTICAL CABLE. ONE (1) OPEN CONDUIT (NO

INNERDUCT) SHALL BE DEDICATED FOR ONE (1)

100-PAIR OSP UTP COPPER CABLE. TWO (2)

CONDUIT (WITH INNERDUCT) SHALL BE

DEDICATED FOR SPARES.

2. EXISTING TO REMAIN.

3. ABANDONED IN PLACE.

4. ONE (1) 3" CONDUIT INSTALLED BETWEEN TER

100 TO THE TRANSFORMER PAD LOCATED AT

THE SOUTHWEST CORNER OF THE HANGAR

BUILDING.

EXISTING COMMUNICATION UNDERGROUND

CONDUITS TO BE DEMOLISHED

Cux

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

W

P W

A P

W A

P W

A P

W A

P W

A P

W A

P W

A P

W A

P

W A

P

WAP

WAP

WAP

WAP

WAP

TV TV

TV TV

A V

WAP WAP

EPEP

W W

W

W

T

T

T D

D C

T W

W W

W

W

W

W

W

W

W

W

W

W

PA

PA

PA

PA PA PA

PA

PA PA

PA

PA

PA PA

PA

PA

PA

PA

P A

PA PA

PA PA

PA

PA

P A

PA

P A

P A

P A

P A

P A

P A P

A

P A

P A

P A

W

T T

T T

T

W

P A

P A

P A

W

W

T

A V

D D

C

PA

P

A

P A

PA

PA

PA

PAPA

PA

PA

PA

PA

PA

PA

PA

PA

PA

PA

PA

PA

PA

PA

PA

PA

DDC

A

B

C

D

E

F

G

H

J

K

L

M

N

M.1

0.0 0.2 0.9 1 2 3 4 5 5.2 6.2 7 7.8 8.8 9 10 11 1312

TOOL CRIB

FUEL

CELL

TOOL

ROOM

ELEC

MECHANICAL ROOM

RESTROOM WOMEN'S

G003

HALLWAY

C001

MENS LOCKER RM

G006

MECH

TER

LOBBY

L001

RESTROOM

G002

VESTIBULE

V001

J.C.

G001

CORRIDOR

C002

BREAKROOM

OFFICE

OFFICE

OPEN

OFFICE

WOMENS

LOCKER

RM

G005

RESTROOM MEN'S

G004

/1 T-111

/1 T-113

/1 T-112

/1 T-114

/1 T-111

/1 T-113

/1 T-112

/1 T-114

/1 T-113

/1 T-115

/1 T-114

T -1

T -1

FIRE

PUMP

AND

FOAM

TANK

ROOM

TR

ELECTRICAL

ROOM

EQUIP CLOSET

104A

HANGAR

PNN

1 2 3 4 5

A

B

C

D

PLATE REFERENCE

NUMBER

SHEET OF

P L

O T

D A

T E

P

L O

T S

C A

L E

S U

B M

IT

T

E D

B Y

D W

N B

Y

D E

S

IG

N E

D B

Y

C K

D B

Y

D A

T E

S

IZ

E E

F

IL

E N

A M

E

"X

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

US ARMY CORPS

OF ENGINEERS

PHILADELPHIA

DISTRICT

D O

V E

R A

IR

F

O R

C E

B A

S E

A

IR

C R

A F

T M

A

IN

T E

N A

N C

E F

A C

IL

IT

Y

A S

N O

T E

D

-0

-0

W

B U

- 1 -R

-0

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S

A B

C D

E

KEY PLAN

1 2 3 4 5

/1

/2

:0

:3

P M

T-110

T E

L E

C O

M M

U N

IC

A

T

IO

N S

F

L O

O R

P L

A N

C

O M

P R

E H

E N

S

IV

E

D K

B R

M S

M V

R T

A

D

E C

D

E C

SCALE: 1/16" = 1'-0"

TELECOMMUNICATIONS - FLOOR PLAN - COMPREHENSIVE

GENERAL NOTES

1. SEE DWG T-001 FOR TELECOMMUNICATIONS

NOTES, SYMBOLS, AND ABBREVIATIONS.

SCALE:

8'-0" 16'-0" 32'-0"

0'-0 1/16" = 1'-0"

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

P

W A P

WAP

WAP

WAP

TV TV

TV TV

A V

T

T

T

T

W W

W W

W

W

W

PA

PA

PA

PA PA

PA

PA

PA

P A

P A

T T

T T

T

T

A V

PA

PA

PA

PAPA

PA

PA

PA

PA

PA

PA

PA

PA

PA

PA

PA

PA

PA

PA

PA

PA

T-111 T-401

RESTROOM WOMEN'S

G003

HALLWAY

C001

TER

A

B

C

D

E

0.0 0.2 0.9 1 2 3 4 5 5.2 6.2 7

LOBBY

L001

RESTROOM

G002

VESTIBULE

V001

J.C.

G001

BREAKROOM

OFFICE

OFFICE

OPEN OFFICE

WOMENS LOCKER RM

G005

RESTROOM MEN'S

G004

/1 T-113 /1 T-113

/1 T-112

/1 T-114

T -1

EQUIP CLOSET

104A

2 2

2 2

HANGAR

PNN

1 2 3 4 5

A

B

C

D

PLATE REFERENCE

NUMBER

SHEET OF

P L

O T

D A

T E

P

L O

T S

C A

L E

S U

B M

IT

T

E D

B Y

D W

N B

Y

D E

S

IG

N E

D B

Y

C K

D B

Y

D A

T E

S

IZ

E E

F

IL

E N

A M

E

"X

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

US ARMY CORPS

OF ENGINEERS

PHILADELPHIA

DISTRICT

D O

V E

R A

IR

F

O R

C E

B A

S E

A

IR

C R

A F

T M

A

IN

T E

N A

N C

E F

A C

IL

IT

Y

A S

N O

T E

D

-0

-0

W

B U

- 1 -R

-0

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S

A B

C D

E

KEY PLAN

1 2 3 4 5

/1

/2

:0

:4

P M

T-111

T E

L E

C O

M M

U N

IC

A

T

IO

N S

F

L O

O R

P L

A N

A

R E

A A

D K

B R

M S

M V

R T

A

D

E C

D

E C

SCALE: 1/8" = 1'-0"T-111

1 TELECOMMUNICATIONS - FLOOR PLAN - AREA A

SCALE:

4'-0" 8'-0" 16'-0"

0'-0 1/8" = 1'-0"

GENERAL NOTES

1. SEE DWG T-001 FOR TELECOMMUNICATIONS

NOTES, SYMBOLS, AND ABBREVIATIONS.

2. EACH WIRELESS ACCESS POINT (WAP) OUTLET

SHALL BE MOUNTED AT 12-INCHES ABOVE

FINISHED CEILING, EXCEPT IN THE HANGAR BAY

AREAS.

3. WIRELESS ACCESS POINT (WAP) OUTLET IN THE

HANGAR BAY AREAS SHALL BE WALL-MOUNTED

AT 11'-0" AFF.

4. ALL ELECTRICAL EQUIPMENT, WAP AND PA

SPEAKERS, IN THE HANGAR BAY IS REQUIRED TO

BE IN A NEMA 250 TYPE 3R OR WEATHER PROOF

ENCLOSURE.

KEYNOTES

1. A FLAT SCREEN DIGITAL SIGNAGE MONITOR

SHALL BE LOCATED IN THE MAIN HALLWAY NEAR

THE MAIN ENTRY. CONTENT SHALL BE

CONTROLLED BY A LOCAL DIGITAL SIGNAGE

APPLIANCE TO BE LOCATED AT A DESK IN THE

ADMIN AREA. HDMI CONNECTIVITY BETWEEN

THESE TWO WITH ONE (1) HDMI CONNECTOR AT

THE MONITOR AND ONE (1) HDMI CONNECTOR AT

THE DESK WITH THE DIGITAL SIGNAGE

APPLIANCE.

2. FLAT SCREEN TELEVISIONS IN BREAKROOM 104

SHALL EACH HAVE ONE (1) CATV RF COAXIAL

CONNECTOR.

3. THREE (3) 4-INCH SCH. 40 PVC CONDUITS WITH

THREE (3) THREE-CELL FABRIC MESH INNER-

DUCTS INSTALLED IN EACH CONDUIT INSTALLED

BETWEEN THE EF/TER, ROOM 100, AND THE TR,

ROOM 110, ROUTED BENEATH THE FLOOR SLAB.

REFERENCE DETAIL 4 ON DRAWING T-502.

4. PROVIDE 12X4 CABLE TRAY.

5. ONE (1) HDMI CONNECTOR FOR THE DIGITAL

SIGNAGE APPLIANCE WITH ONE (1) HDMI CABLE

TO THE HDMI CONNECTOR AT THE DIGITAL

SIGNAGE MONITOR.

T-110

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

P

W A P

W P A

P A

A

B

C

D

E

7 7.8 8.8 9 10 11 1312

/1 T-114

/1 T-111

/1 T-113 /1 T-114

T -1

HANGAR

PNN

1 2 3 4 5

A

B

C

D

PLATE REFERENCE

NUMBER

SHEET OF

P L

O T

D A

T E

P

L O

T S

C A

L E

S U

B M

IT

T

E D

B Y

D W

N B

Y

D E

S

IG

N E

D B

Y

C K

D B

Y

D A

T E

S

IZ

E E

F

IL

E N

A M

E

"X

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

US ARMY CORPS

OF ENGINEERS

PHILADELPHIA

DISTRICT

D O

V E

R A

IR

F

O R

C E

B A

S E

A

IR

C R

A F

T M

A

IN

T E

N A

N C

E F

A C

IL

IT

Y

A S

N O

T E

D

-0

-0

W

B U

- 1 -R

-0

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S

A B

C D

E

KEY PLAN

1 2 3 4 5

/1

/2

:0

:4

P M

T-112

T E

L E

C O

M M

U N

IC

A

T

IO

N S

F

L O

O R

P L

A N

A

R E

A B

D K

B R

M S

M V

R T

A

D

E C

D

E C

SCALE: 1/8" = 1'-0"T-112

1 TELECOMMUNICATIONS - FLOOR PLAN - AREA B

GENERAL NOTES

1. SEE DWG T-001 FOR TELECOMMUNICATIONS

NOTES, SYMBOLS, AND ABBREVIATIONS.

2. WIRELESS ACCESS POINT (WAP) OUTLET IN THE

HANGAR BAY AREAS SHALL BE WALL-MOUNTED

AT 11'-0" AFF.

3. ALL ELECTRICAL EQUIPMENT, WAP AND PA

SPEAKERS, IN THE HANGAR BAY IS REQUIRED TO

BE IN A NEMA 250 TYPE 3R OR WEATHER PROOF

ENCLOSURE.

SCALE:

4'-0" 8'-0" 16'-0"

0'-0 1/8" = 1'-0"

T-110

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

P W

A P

WAP

WAP

WAP

EP EP

W W

D D

C W

W

PA

PA PA PA

PA

PA PA

PA

PA

PA

P A

PA

P A

P A

P A

P A

P A

P A

P A

P A

W

DDC

TOOL CRIB

FUEL CELL TOOL ROOM

ELEC

MECHANICAL ROOM

MENS LOCKER RM

G006

HANGAR

F

G

H

J

K

0.0 0.2 0.9 1 2 3 4 5 5.2 6.2 7

CORRIDOR

C002

RESTROOM MEN'S

G004

/1 T-111 /1 T-111 /1 T-112

/1 T-114

/1 T-115

/1 T-114

PNN

1 2 3 4 5

A

B

C

D

PLATE REFERENCE

NUMBER

SHEET OF

P L

O T

D A

T E

P

L O

T S

C A

L E

S U

B M

IT

T

E D

B Y

D W

N B

Y

D E

S

IG

N E

D B

Y

C K

D B

Y

D A

T E

S

IZ

E E

F

IL

E N

A M

E

"X

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

US ARMY CORPS

OF ENGINEERS

PHILADELPHIA

DISTRICT

D O

V E

R A

IR

F

O R

C E

B A

S E

A

IR

C R

A F

T M

A

IN

T E

N A

N C

E F

A C

IL

IT

Y

A S

N O

T E

D

-0

-0

W

B U

- 1 -R

-0

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S

A B

C D

E

KEY PLAN

1 2 3 4 5

/1

/2

:0

:5

P M

T-113

T E

L E

C O

M M

U N

IC

A

T

IO

N S

F

L O

O R

P L

A N

A

R E

A C

D K

B R

M S

M V

R T

A

D

E C

D

E C

SCALE: 1/8" = 1'-0"T-113

1 TELECOMMUNICATIONS - FLOOR PLAN - AREA C

GENERAL NOTES

KEYNOTES

1. SEE DWG T-001 FOR TELECOMMUNICATIONS

NOTES, SYMBOLS, AND ABBREVIATIONS.

2. WIRELESS ACCESS POINT (WAP) OUTLET IN THE

HANGAR BAY AREAS SHALL BE WALL-MOUNTED

AT 11'-0" AFF.

3. ALL ELECTRICAL EQUIPMENT, WAP AND PA

SPEAKERS, IN THE HANGAR BAY IS REQUIRED TO

BE IN A NEMA 250 TYPE 3R OR WEATHER PROOF

ENCLOSURE.

SCALE:

4'-0" 8'-0" 16'-0"

0'-0 1/8" = 1'-0"

1. THREE (3) 4-INCH SCH. 40 PVC CONDUITS WITH

THREE (3) THREE-CELL FABRIC MESH INNER-

DUCTS INSTALLED IN EACH CONDUIT INSTALLED

BETWEEN THE EF/TER, ROOM 100, AND THE TR,

ROOM 110, ROUTED BENEATH THE FLOOR SLAB.

REFERENCE DETAIL 4 ON DRAWING T-502.

2. CRASH PHONES: ONE SHALL BE RED IN COLOR

AND THE OTHER BLUE IN COLOR.

3. COORDINATE WITH MECHANICAL FOR DDC

LOCATION.

4. PROVIDE TWO (2) 4-INCH PVC CONDUITS.

5. PROVIDE 12X4 CABLE TRAY.

T-110

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

P

W A P

WAPPA

W P A

W

PA

T-114 T-401

HANGAR

F

G

H

J

K

7 7.8 8.8 9 10 11 1312

/1 T-112/1 T-111

/1 T-113

/1 T-112

/1 T-113

/1 T-115

TR

ELECTRICAL

ROOM

PNN

1 2 3 4 5

A

B

C

D

PLATE REFERENCE

NUMBER

SHEET OF

P L

O T

D A

T E

P

L O

T S

C A

L E

S U

B M

IT

T

E D

B Y

D W

N B

Y

D E

S

IG

N E

D B

Y

C K

D B

Y

D A

T E

S

IZ

E E

F

IL

E N

A M

E

"X

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

US ARMY CORPS

OF ENGINEERS

PHILADELPHIA

DISTRICT

D O

V E

R A

IR

F

O R

C E

B A

S E

A

IR

C R

A F

T M

A

IN

T E

N A

N C

E F

A C

IL

IT

Y

A S

N O

T E

D

-0

-0

W

B U

- 1 -R

-0

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S

A B

C D

E

KEY PLAN

1 2 3 4 5

/1

/2

:0

:0

P M

T-114

T E

L E

C O

M M

U N

IC

A

T

IO

N S

F

L O

O R

P L

A N

A

R E

A D

D K

B R

M S

M V

R T

A

D

E C

D

E C

SCALE: 1/8" = 1'-0"T-114

1 TELECOMMUNICATIONS - FLOOR PLAN - AREA D

GENERAL NOTES

KEYNOTES

1. SEE DWG T-001 FOR TELECOMMUNICATIONS NOTES,

SYMBOLS, AND ABBREVIATIONS.

2. WIRELESS ACCESS POINT (WAP) OUTLET IN THE

HANGAR BAY AREAS SHALL BE WALL-MOUNTED AT 11'-

0" AFF.

3. ALL ELECTRICAL EQUIPMENT, WAP AND PA SPEAKERS,

IN THE HANGAR BAY IS REQUIRED TO BE IN A NEMA 250

TYPE 3R OR WEATHER PROOF ENCLOSURE.

SCALE:

4'-0" 8'-0" 16'-0"

0'-0 1/8" = 1'-0"

1. THREE (3) 4-INCH SCH. 40 PVC CONDUITS WITH

THREE (3) THREE-CELL FABRIC MESH INNER-

DUCTS INSTALLED IN EACH CONDUIT INSTALLED

BETWEEN THE EF/TER, ROOM 100, AND THE TR,

ROOM 110, ROUTED BENEATH THE FLOOR SLAB.

REFERENCE DETAIL 4 ON DRAWING T-502.

T-110

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

P

W A P

W

W

W

W

W

PA PA

PA

PA

P A

PA

W

D D C

PA

P A

T-114 T-401

MECH

K

L

M

N

M.1

5 5.2 6.2 7 7.8 8.8 9 10 11 1312

/1 T-113 /1 T-114

FIRE PUMP AND FOAM

TANK ROOM

TR

ELECTRICAL

ROOM

PNN

1 2 3 4 5

A

B

C

D

PLATE REFERENCE

NUMBER

SHEET OF

P L

O T

D A

T E

P

L O

T S

C A

L E

S U

B M

IT

T

E D

B Y

D W

N B

Y

D E

S

IG

N E

D B

Y

C K

D B

Y

D A

T E

S

IZ

E E

F

IL

E N

A M

E

"X

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

US ARMY CORPS

OF ENGINEERS

PHILADELPHIA

DISTRICT

D O

V E

R A

IR

F

O R

C E

B A

S E

A

IR

C R

A F

T M

A

IN

T E

N A

N C

E F

A C

IL

IT

Y

A S

N O

T E

D

-0

-0

W

B U

- 1 -R

-0

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S

A B

C D

E

KEY PLAN

1 2 3 4 5

/1

/2

:0

:0

P M

T-115

T E

L E

C O

M M

U N

IC

A

T

IO

N S

F

L O

O R

P L

A N

A

R E

A E

D K

B R

M S

M V

R T

A

D

E C

D

E C

SCALE: 1/8" = 1'-0"T-115

1 TELECOMMUNICATIONS - FLOOR PLAN - AREA E

GENERAL NOTES

KEYNOTES

1. SEE DWG T-001 FOR TELECOMMUNICATIONS

NOTES, SYMBOLS, AND ABBREVIATIONS.

2. WIRELESS ACCESS POINT (WAP) OUTLET IN THE

HANGAR BAY AREAS SHALL BE WALL-MOUNTED

AT 11'-0" AFF.

3. ALL ELECTRICAL EQUIPMENT, WAP AND PA

SPEAKERS, IN THE HANGAR BAY IS REQUIRED TO

BE IN A NEMA 250 TYPE 3R OR WEATHER PROOF

ENCLOSURE.

SCALE:

4'-0" 8'-0" 16'-0"

0'-0 1/8" = 1'-0"

1. THREE (3) 4-INCH SCH. 40 PVC CONDUITS WITH

THREE (3) THREE-CELL FABRIC MESH INNER-

DUCTS INSTALLED IN EACH CONDUIT INSTALLED

BETWEEN THE EF/TER, ROOM 100, AND THE TR,

ROOM 110, ROUTED BENEATH THE FLOOR SLAB.

T-110

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

P

A

W P

A

TER

(TYP) 1

2 4 5 6

TR

(TYP)

TGB5

1 2 3 4 5

A

B

C

D

PLATE REFERENCE

NUMBER

SHEET OF

P L

O T

D A

T E

P

L O

T S

C A

L E

S U

B M

IT

T

E D

B Y

D W

N B

Y

D E

S

IG

N E

D B

Y

C K

D B

Y

D A

T E

S

IZ

E E

F

IL

E N

A M

E

"X

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

US ARMY CORPS

OF ENGINEERS

PHILADELPHIA

DISTRICT

D O

V E

R A

IR

F

O R

C E

B A

S E

A

IR

C R

A F

T M

A

IN

T E

N A

N C

E F

A C

IL

IT

Y

A S

N O

T E

D

-0

-0

W

B U

- 1 -R

-0

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S

1 2 3 4 5

/1

/2

:0

:1

P M

T-401

T E

L E

C O

M M

U N

IC

A

T

IO

N S

E N

L A

R G

E D

P L

A N

S

D K

B R

M S

M V

R T

A

D

E C

D

E C

SCALE: 1/4" = 1'-0"T-111 T-401

1 TELECOMMUNICATIONS - ENLARGED TER RM 100

SCALE: 1/4" = 1'-0"T-114 T-401

2 TELECOMMUNICATIONS - ENLARGED TR RM 110

SCALE:

2'-0" 4'-0" 8'-0"

0'-0 1/4" = 1'-0"

GENERAL NOTES

KEYNOTES

1. SEE DWG T-001 FOR TELECOMMUNICATIONS

NOTES, SYMBOLS, AND ABBREVIATIONS.

2. WIRELESS ACCESS POINT (WAP) OUTLET IN THE

HANGAR BAY AREAS SHALL BE WALL-MOUNTED AT

11'-0" AFF.

3. THREE (3) CATEGORY-6 OUTSIDE PLANT RATED

U/UTP CABLES INSTALLED INTO THE 3" CONDUIT TO

THE TRANSFORMER PAD FOR DDC. EACH PASSING

THROUGH A CATEGORY-6 DATA LINE NETWORK

SURGE PROTECTOR MODULE LOCATED IN TER 100

PRIOR TO THE NETWORK SWITCH. TERMINATE

EACH U/UTP CABLE ONTO AN 8P8C RJ45-TYPE

JACK, RATED FOR OUTDOOR INSTALLATION,

INSTALLED INTO A NEMA-4X OUTLET ENCLOSURE

AT THE TRANSFORMER PAD. COORDINATE WITH

ELECTRICAL.

1. 8' HIGH x 3/4" THICK, AC GRADE, VOID FREE, FIRE

RATED PLYWOOD BACKBOARD COVERING THREE

WALLS. DO NOT PAINT. PLYWOOD IS TO BE

INSTALLED 8" AFF.

2. FOUR (4) 4" CONDUITS FROM OSP. CONDUITS ARE

TO BE STUBBED UP 4"-6" AFF.

3. TELECOMMUNICATIONS MAIN GROUNDING

BUSBAR (TMGB); 1/4" THICK X 24" LONG X 4" WIDE,

MOUNTED AT 78" AFF; SEE DETAIL 1 ON DWG T-502.

4. BUILDING ENTRANCE TERMINAL (BET).

5. WALL-MOUNTED, 110-TYPE CONNECTOR BLOCKS

WITH C-5 CLIPS FOR COPPER BACKBONE

TERMINATIONS.

6. CATV BROADBAND INDOOR DISTRIBUTION

AMPLIFIER.

7. WALL-MOUNTED PHONE OUTLET WITH ONE (1)

CATEGORY 6 CABLE MOUNTED AT 57" AFF.

8. THREE (3) 4" CONDUITS FROM TER 100 TO TR 110.

9. ONE (1) 2" CONDUIT EXTENDED TO FIVE (5) FEET

PAST BUILDING FOR CATV SERVICE PROVIDER.

10. ONE (1) 3" CONDUIT INSTALLED BETWEEN TER 100

TO THE TRANSFORMER PAD LOCATED AT THE

SOUTHWEST CORNER OF THE HANGER BUILDING.

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

MODULAR RJ45

CONNECTOR

1" CONDUIT

(MINIMUM)

4" H x 2 1/8" W x 2 1/8" D

OUTLET BOX WITH

SINGLE GANG

PLASTER RING

DDC

MOUNTING LUGS

MODULAR RJ45

CONNECTOR

W

1" CONDUIT

(MINIMUM)

4" H x 2 1/8" W x 2 1/8" D

OUTLET BOX WITH SINGLE

GANG PLASTER RING.

MOUNTED AT 57" AFF

EP

F-TYPE

CONNECTOR

TV

1" CONDUIT

(MINIMUM)

4" H x 2 1/8" W x 2 1/8" D

OUTLET BOX WITH SINGLE

GANG PLASTER RING.

MOUNTED AT 72" AFF

DATA

MODULAR RJ45

CONNECTOR

1" CONDUIT

(MINIMUM)

5" SQUARE x 2 7/8"

DEEP OUTLET BOX

WITH SINGLE GANG

PLASTER RING

BLANK COVER

DATA

MODULAR RJ45

CONNECTOR

VOICE

MODULAR RJ45

CONNECTOR

1" CONDUIT

(MINIMUM)

5" SQUARE x 2 7/8"

DEEP OUTLET BOX

WITH SINGLE GANG

PLASTER RING

DATA

MODULAR RJ45

CONNECTOR

DATA

MODULAR RJ45

CONNECTOR

VOICE

MODULAR RJ45

CONNECTOR

DATA

MODULAR RJ45

CONNECTOR

T

CABLE TRAY

INSULATED GROUND BUSHING

WITH #6 AWG CONDUCTOR TO

CABLE TRAY BONDING

CONDUCTOR

1" CONDUIT

CABLE TRAY

CONDUIT

CLAMP

1' -0

0'

-3

TELECOMM WALL

OUTLET BOX

SEE DETAILS 1 - 4

OF T-501 FOR

OUTLET DETAILS.

MIN. CLEARANCE

MIN.

CEILING

1/4"

HOLE (TYP)

TELECOMMUNICATIONS MAIN GROUNDING BUSBAR (TMGB) AT THE EF/TER, IN ACCORDANCE WITH ANSI/TIA-607-C, SERVES AS THE DEDICATED EXTENSION OF THE BUILDING AC GROUNDING (EARTHING) ELECTRODE SYSTEM FOR THE TELECOMMUNICATIONS INFRASTRUCTURE. IT SERVES AS THE CENTRAL ATTACHMENT POINT FOR THE

TELECOMMUNICATIONS BONDING BACKBONE (TBB) AND TELECOMMUNICATIONS EQUIPMENT.

THE WALL MOUNTED TMGB MUST BE A PREDRILLED WITH STANDARD 5/16" HOLES IN A 2 HOLE CONFIGURATION, OF COPPER OR A COPPER ALLOY WITH A MINIMUM OF 95% CONDUCTIVITY, BE ELECTROTIN0PLATED (ETP) TO REDUCE CONTACT RESISTANCE AND CORROSION, WITH MINIMUM DIMENSIONS OF 0.25 INCH THICKNESS BY 4

INCH WIDTH AND BE A MINIMUM OF 24 INCHES IN LENGTH.

THE TMGB IS BONDED TO THE MAIN ELECTRICAL SERVICE GROUNDING ELECTRODE SYSTEM AT THE MAIN SWITCHBOARD WITH A BONDING CONDUCTOR FOR TELECOMMUNICATIONS (BCT) CONDUCTOR USING

IRREVERSIBLE, HIGH COMPRESSION OR PERMANENT EXOTHERMIC CONNECTIONS.

4"

24"

(TYP)

(TYP)

ICT RACK 1 ICT RACK 2

(TYP) (TYP)(TYP)

(TYP)

(TYP) (TYP)

(TYP)

(TYP)

ICT RACK

(TYP REAR)

INDIVIDUAL EQUIPMENT

GROUNDING TERMINAL

(TYP)

TECB

10 13

1/4"

HOLE (TYP)

TELECOMMUNICATIONS GROUNDING BUSBAR (TGB) IN THE TELECOMMUNICATIONS SPACES, IN

ACCORDANCE WITH ANSI/TIA-607-B, IS THE GROUNDING (EARTHING) CONNECTION POINT FOR

TELECOMMUNICATIONS INFRASTRUCTURE SYSTEMS (E.G., CABLING, PATHWAYS) AND

TELECOMMUNICATIONS EQUIPMENT IN THE AREA SERVED BY A TER OR A TR.

THE WALL MOUNTED TGB MUST BE A PREDRILLED WITH STANDARD 5/16" HOLES IN A 2 HOLE

CONFIGURATION, OF COPPER OR A COPPER ALLOY WITH A MINIMUM OF 95% CONDUCTIVITY, BE

ELECTROTIN0PLATED (ETP) TO REDUCE CONTACT RESISTANCE AND CORROSION, WITH MINIMUM

DIMENSIONS OF 0.25 INCH THICKNESS BY 2 INCH WIDTH AND BE A MINIMUM OF 24 INCHES IN LENGTH.

THE TGB SHALL BE BONDED TO THE TMGB AND TO THE MAIN ELECTRICAL SERVICE GROUNDING ELECTRODE

SYSTEM WITH A BONDING CONDUCTOR FOR TELECOMMUNICATIONS (BCT) CONDUCTOR USING

IRREVERSIBLE, HIGH COMPRESSION OR PERMANENT EXOTHERMIC CONNECTIONS AND BE BONDED TO THE NEAREST STRUCTURAL STEEL MEMBER, WHETHER IT IS A HORIZONTAL OR VERTICAL BEAM, IF AVAILABLE.

2"

24"

1 2 3 4 5

A

B

C

D

PLATE REFERENCE

NUMBER

SHEET OF

P L

O T

D A

T E

P

L O

T S

C A

L E

S U

B M

IT

T

E D

B Y

D W

N B

Y

D E

S

IG

N E

D B

Y

C K

D B

Y

D A

T E

S

IZ

E E

F

IL

E N

A M

E

"X

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

US ARMY CORPS

OF ENGINEERS

PHILADELPHIA

DISTRICT

D O

V E

R A

IR

F

O R

C E

B A

S E

A

IR

C R

A F

T M

A

IN

T E

N A

N C

E F

A C

IL

IT

Y

A S

N O

T E

D

-0

-0

W

B U

- 1 -R

-0

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S

1 2 3 4 5

/1

/2

:0

:2

P M

T-501

T E

L E

C O

M M

U N

IC

A

T

IO

N S

D E

T A

IL

S

D K

B R

M S

M V

R T

A

D

E C

D

E C

SCALE: NTST-501

1 TYPICAL DDC OUTLET

T-501 SCALE: NTST-501

4 TYPICAL WALL PHONE OUTLET

T-501

SCALE: NTST-501

5 TYPICAL CATV OUTLET

T-501

SCALE: NTST-501

2 TYPICAL DUPLEX ICT OUTLET

T-501 SCALE: NTST-501

3 TYPICAL TRIPLEX ICT OUTLET

T-501

SCALE: NTST-501

11 CABLE TRAY TO OUTLET CONDUIT TRANSITION

T-501SCALE: NTST-501

TELECOMMUNICATIONS MAIN GROUNDING

BUSBAR, TMGB

T-501

SCALE: NTST-501

8 TYPICAL RGB ENLARGED DETAIL

T-501SCALE: NTST-501

6 EQUIPMENT RACK ELEVATIONS

T-501 SCALE: NTST-501

7 TYPICAL EQUIPMENT RACK REAR VIEW

T-501

GENERAL NOTES

KEYNOTES

1. SEE DWG T-001 FOR TELECOMMUNICATIONS

NOTES, SYMBOLS, AND ABBREVIATIONS.

SCALE: NTST-501

TELECOMMUNICATIONS GROUNDING BUSBAR,

TGB

T-501

1. 7'H X 6"W X 14.61"D DOUBLE SIDED, DOUBLE

HINGED VERTICAL WIRE MANAGERS.

2. 7'H X 20.3"W TWO-POST 19-INCH EQUIPMENT

RACK WITH 6" VERTICAL WIRE MANAGERS AND

RMU MARKINGS FOR SUPPORT UP TO 1500 LB

STATIC LOAD RATING.

3. 2 RU HORIZONTAL WIRE MANAGEMENT UNIT.

4. 48 PORT, 2 RU, CATEGORY 6, PATCH PANELS

FOR HORIZONTAL CABLES WITH T568A WIRING

FOR 110 STYLE IDC TERMINATIONS.

5. CFCI 7"H X 19"W X 17"D RACK-MOUNTED

CORNING CLOSET CONNECTOR HOUSING (CCH)

FOR DUPLEX SC ADAPTERS, FOR 12-SM OS2

FIBERS; PART NUMBER CCH-04U; HOLDS 12

CCH PANELS AND IS 4RU; SPECIFICALLY USED

IN TER 124 FOR TERMINATING BACKBONE

CABLE FROM EF AND TO TR 106 AND TR 126.

6. LADDER TYPE, CABLE RUNWAY, MADE UP OF

STEEL TUBING WITH CROSS MEMBERS WELDED

AT 12" INTERVALS.

7. CABLE RUNWAY ELEVATION BRACKETS WITH A

4-6" STAND-OFF FROM THE TOP OF THE

EQUIPMENT RACK.

8. CABLE RUNWAY RADIUS DROP, MOUNTS TO

RUNWAY CROSS MEMBER.

9. 24-PORT, 1 RU POTS PATCH PANEL.

10. L5-20R TWIST LOCK RECEPTACLE MOUNTED ON

THE CABLE TRAY ABOVE TELECOM RACK.

11. 1 INCH X 19 INCH RACK MOUNTED RGB

LOCATED 1 RU FROM THE TOP, BONDED TO

TGB. REFERENCE DETAIL 5 OF T-603.

12. STANDARD RACK HARDWARE.

13. L6-20R TWIST LOCK RECEPTACLE MOUNTED ON

THE CABLE TRAY ABOVE TELECOM RACK.

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

RGS OR IMC BUSHING

RGS/IMC CONDUIT EXTENDED UP

TO EQUIPMENT AS DIRECTED ON

CONSTRUCTION DRAWINGS

FINISHED FLOOR

RGS/IMC SWEEP. SIZE TO MATCH RGS/IMC

CONDUIT. SWEEP RADIUS TO BE

CONSISTENT WITH DEPTH OF BURIED

RGS/IMC CONDUIT

4" TO

6" AFF

CUT PVC CONDUIT AND ATTACH A

THREADED / COMPRESSION RGS/IMC

ADAPTOR OR FITTING AS REQUIRED

UNDERGROUND PVC CONDUIT

NOTE:

NON METALLIC CONDUIT, OTHER THAN PVC SCH 40 OR 80 SHALL BE CONVERTED

TO PLASTIC COATED RIGID, OR IMC, STEEL CONDUIT BEFORE RISING THROUGH

THE FLOOR SLAB WITH APPROPRIATE SWEEPS AND COUPLINGS.

GROUNDING BUSHING4" TO 6" AFF.

FIRE-RATED A-C PLYWOOD

BACKBOARD (SEE NOTE BELOW)

NOTE:

RIDIGLY-FIXED FIRE-RATED, 3/4" A-C PLYWOOD BACKBOARD, PREFERABLY VOID-FREE

WITH THE A-SIDE OUT, INSTALLED 6" AFF TO 8'-6" AFF, CAPABLE F SUPPORTING

ATTACHED EQUIPMENT. THE FIRE STAMP SHALL BE CLEARLY VISIBLE, DO NOT PAINT.

RF CABLE FROM CATV

SERVICE PROVIDER

COAXIAL CABLE

GROUNDING BLOCK

CATV DISTRIBUTION

AMPLIFIER

8-WAY CATV SPLITTER, BLONDER

TONGUE MODEL SDS-8 OR

APPROVED EQUIVALENT, WALL

MOUNTED, CONNECTING ALL RG6

COAXIAL DISTRIBUTION CABLE.

FINAL GRADE

MARKING12

M

IN

SELECTED BACKFILL

(NO STONES OVER

3" DIAMETER)

(2) - 4" CONDUIT WITH

(3) - 3" - 3 CELL FABRIC

MESH INNERDUCT

CONCRETE

M

IN

1'-10" MIN

AROUND)

3"

(TYP ALL

2" MIN

2' -0 M

IN

SPARE

FINAL GRADE

MARKING12

M

IN

SELECTED BACKFILL

(NO STONES OVER

3" DIAMETER)

(3) - 4" CONDUIT WITH

(3) - 3" - 3 CELL FABRIC

MESH INNERDUCT

CONCRETE

M

IN

2'-4" MIN

AROUND)

3"

(TYP ALL

2" MIN

2' -0 M

IN

SPARE

STRUT CHANNELLADDER RACK HOLD DOWN

CLAMP WITH HEX

HEAD BOLT & STRUT

CHANNEL NUT

10mm THREADED ROD

FLAT

WASHER

AND NUT

LADDER RACK

SINGLE POINT

BRACKET

LOCK

WASHER

AND NUT

10mm THREADED ROD

LADDER RACK

ELEVATION KIT

480mm

TELECOM

M

RACK

LADDER RACK

(AS SHOWN ON PLANS)

LADDER RACK HOLD

DOWN CLAMP WITH HEX

HEAD BOLT & STRUT

CHANNEL NUT

SPACE SUPPORTS ACCORDING TO CABLE TRAY

WORKING LOAD RATING AND CABLE TRAY

MANUFACTURER RECOMMENDATIONS. FIRST

SUPPORT MUST BE WITHIN 300mm OF SPLICE WITH

A MAXIMUM OF ONE SPLICE BETWEEN SUPPORTS.

UNISTRUT CHANNEL

AND BRACING

SURFACE MOUNTED

PLATE

1. SURFACE MOUNTED CHANNEL MUST BE SECURELY FASTENED

INTO THE SLAB, WALL, ETC. SUFFICIENTLY TO CARRY THE LOAD

OF THE TRAY AND ITS CONTENTS WITH A SAFETY FACTOR OF 3.

2. ALL CHANNEL, TRAY FITTINGS AND ACCESSORIES ARE TO BE

GALVANIZED.

1 2 3 4 5

A

B

C

D

PLATE REFERENCE

NUMBER

SHEET OF

P L

O T

D A

T E

P

L O

T S

C A

L E

S U

B M

IT

T

E D

B Y

D W

N B

Y

D E

S

IG

N E

D B

Y

C K

D B

Y

D A

T E

S

IZ

E E

F

IL

E N

A M

E

"X

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

US ARMY CORPS

OF ENGINEERS

PHILADELPHIA

DISTRICT

D O

V E

R A

IR

F

O R

C E

B A

S E

A

IR

C R

A F

T M

A

IN

T E

N A

N C

E F

A C

IL

IT

Y

A S

N O

T E

D

-0

-0

W

B U

- 1 -R

-0

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S

1 2 3 4 5

/1

/2

:0

:2

P M

T-502

T E

L E

C O

M M

U N

IC

A

T

IO

N S

D E

T A

IL

S

D K

B R

M S

M V

R T

A

D

E C

D

E C

SCALE: NTST-502

1 PVC TO RGS OR IMC CONDUIT STUB UP DETAIL

T-502 SCALE: NTST-502

4" ENTRANCE RGS CONDUIT WITH GROUNDING

BUSHING

T-502 SCALE: NTST-502

3 CATV SYSTEM BACKBOARD ELEVATION

T-502

SCALE: NTST-502

TELECOMMUNICATIONS 3-WAY CONCRETE

ENCASED DUCT BANK

T-502 SCALE: NTST-502

TELECOMMUNICATIONS 4-WAY CONCRETE

ENCASED DUCT BANK

T-502

GENERAL NOTES

1. SEE DWG T-001 FOR TELECOMMUNICATIONS

NOTES, SYMBOLS, AND ABBREVIATIONS.

SCALE: NTST-502

LADDER TYPE CABLE RUNWAY TRAPEZE

MOUNTING

T-502SCALE: NTST-502

LADDER TYPE CABLE RUNWAY SINGLE POINT

MOUNTING

T-502SCALE: NTST-502

8 LADDER TYPE CABLE RUNWAY RACK MOUNTING

T-502

SCALE: NTST-502

LADDER TYPE CABLE RUNWAY WALL MOUNTING

DETAIL

T-502

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

#6 AWG GROUND WIRE

GROUND LUG

GROUND LUG

FIRE RATED WALL

FIRE RATED SLEEVE

ASSEMBLY

PENETRATIONS

THROUGH WALL FOR

ACCESS

TO CABLE TRAY (TYP)LADDER RACK

(AS SHOWN ON

ENLARGED PLANS)

1. SURFACE MOUNTED CHANNEL MUST BE SECURELY FASTENED

INTO THE SLAB, WALL, ETC. SUFFICIENTLY TO CARRY THE LOAD

OF THE TRAY AND ITS CONTENTS WITH A SAFETY FACTOR OF 3.

2. ALL CHANNEL, TRAY FITTINGS AND ACCESSORIES ARE TO BE

GALVANIZED.

3. ALL METALIC TELECOMMUNICATIONS PATHWAYS SHALL BE

BONDED TO THE TELECOMMUNICATIONS BONDING BUSBAR

INSIDE THE NEAREST TELECOMMUNICATIONS SPACE I.A.W.

ANSI/TIA-607-C (7.1.5).

1/2"

3/8"

9'-0" AFF.

10'-6" AFF.

12'-0" AFF.

500 MCM INSULATED COPPER

EQUIPMENT GROUND

RUNWAY SPLICE 2012

GROUND STRAP

CABLE BRACKET 24" O.C.

SEE NEWTON FIGURE

2052 DETAIL (TYP)

5/8" ALL THREAD ROD WITH P1000

UNISTRUT TRAPEZE OR (NEWTON

3022-11) AS REQUIRED HANGERS

4'-0" O.C. UP TO P-1000 UNISTRUT

INSTALL ON BOTH SIDES OF

CABLE LADDER

RUNWAY BRACKET 3029-1

2-5/8" HEX NUTS 3014-8

LOCK WASHER 3015-8

SAUNDERS SB-156

WASHER SB-1048-A

NUT SB-1028

CABLE LADDER

NEWTON FIGURE 2004-4 + 12"

NEWTON FIGURE 2003-23 + 16"

NEWTON FIGURE 2003-26 + 24"

NEWTON FIGURE 2003-29 + 30"

NEWTON FIGURE 2003-30 + 36"

JUNCTION

KIT 2014

TOP OF

FLOOR SLAB

m m

T Y

P

FINISHED

CEILING SLAB

VERTICAL WALL BRACKETS

(TYP)

610mm WIDE LADDER TYPE

CABLE RUNWAY

INSTALL GROUND WIRE

(GREEN INSULATED) FROM

TRAY TO GROUND BUSBAR IN

COMM AREA. SEE DWG

T-110 FOR BUSBAR LOCATION.

PROTECTIVE END CAPS (TYP)

RUNWAY FOOT KIT (TYP)THREE (3) 4" CONDUITS

(TYP)

COMMUNICATION

1-1/2" SHARP FACE GOTHIC

(4) 1" HANDLING HOLES ON 35-1/2" BC

(2) CLOSED PICKHOLES

1040A SQ 1-1/2" PH CORE

CORE# 10402010

32" DIA

0' -1

/2

32-1/4" DIA

30" DIA

32-1/4" DIA

38" DIA

ACM PART NUMBER 141983

NOTE: FRAME IS REVERSIBLE.

CAN BE INSTALLED AS A TOP

FLANGE UNIT.

2'-6"

5'-0"

2' -6

5' -0

(4) 1" DIA THREADED

PENNSYLVANIA INSERT

CORPORATION

STEPDOWN (TYP) APPLY

JOINT SEALANT BEFORE

INSTALLING TO PIECE

BELOW

30" DIA ACCESS OPENING

0' -6

0'

-0

/4

3'-11"

0'-6 1/2"

0'-6"

0' -6

2'-0"

4'-0"

2' -0

4' -0

FLAT SURFACE FOR CONNECTION

JOINT SEALANT BEFORE

INSTALLATION

(4) 38-1/2" H x 45" W x 3" D

KNOCKOUT

(4) PAI MOLDED

PULLING IRON

12" DIA x 4" DEEP SUMP

WITH A 1" GROOVE

1" DIA GROUND ROD

KNOCKOUT

1 2 3 4 5

A

B

C

D

PLATE REFERENCE

NUMBER

SHEET OF

P L

O T

D A

T E

P

L O

T S

C A

L E

S U

B M

IT

T

E D

B Y

D W

N B

Y

D E

S

IG

N E

D B

Y : C

K D

B Y

D A

T E

S

IZ

E E

F

IL

E N

A M

E

"X

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

US ARMY CORPS

OF ENGINEERS

PHILADELPHIA

DISTRICT

D O

V E

R A

IR

F

O R

C E

B A

S E

A

IR

C R

A F

T M

A

IN

T E

N A

N C

E F

A C

IL

IT

Y

A S

N O

T E

D

-0

-0

W

B U

- 1 -R

-0

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S

1 2 3 4 5

/1

/2

:4

:4

P M

T-503

T E

L E

C O

M M

U N

IC

A

T

IO

N S

D E

T A

IL

S

D K

B R

M S

M V

R T

A

D

E C

D

E C

GENERAL NOTES

1. SEE DWG T-001 FOR TELECOMMUNICATIONS

NOTES, SYMBOLS, AND ABBREVIATIONS.

SCALE: NTST-503

RE-ENTERABLE MECHANICAL FIRESTOP

ASSEMBLY CABLE TRAY TO LADDER RACK WALL

PENETRATION

T-503 SCALE: NTST-503

LADDER TYPE CABLE RUNWAY WALL MOUNTING

DETAIL

T-503 SCALE: NTST-503

VERTICAL TELECOMMUNICATIONS CABLE

RUNWAY

T-503

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

SCALE: NTST-503

4 MANHOLE COVER

T-503 SCALE: NTST-503

5 MANHOLE

T-503 SCALE: NTST-503

6 HANDHOLE

T-503

EJC T

PA

FROM PBX

FXO PORT

PUBLIC ADDRESS SINGLE-ZONE TELEPHONE INTERFACE DEVICE

SUCH AS THE BOGEN MODEL UTI1

DIGITAL FEEDBACK TERMINATOR

SUCH AS THE BOGEN MODEL DFT120

PUBLIC ADDRESS AMPLIFIER

SUCH AS THE BOGEN MODEL M600

TER 100

HANGAR 105ADMIN AND SUPPORT AREA

PA PA PA

(TYP) (TYP) (TYP)(TYP)

CEILING OR

WALL MOUNTED

SPEAKERS

WEATHERPROOF

WALL MOUNTED

SPEAKERS

1 11

(TYP)

WALL

PHONE

ICT

OUTLET

(TYP)

STANDARD

DUAL ICT

OUTLET

(TYP)

STANDARD

SINGLE

ICT

OUTLET

PLENUM CATEGORY-6 U/UTP CABLE (TYP)

(TYP)

TELECOMM

HORIZONTAL

EQUIPMENT

RACK

(TYP)

WAP

B U

IL

D

IN

G

M E T A L

S T R

U C

T U

R E A

C C

E S S

IB

LE

TER 100

TELECOMMUNICATIONS EQUIPMENT ROOM

EQUIPMENT RACK

NETWORK

SWITCH

ROOM

POWER

PANEL

TMGB

NETWORK

SWITCH

CABLE TRAY BONDING SYSTEM

ELECTRICAL ROOM 107

GROUNDING

ELECTRODE

SYSTEM

MGB

TBB

ANSI/TIA-607-B TBB CONDUCTOR SIZE CHART

TBB/GE LINEAR LENGTH (FEET) AWG #

LESS THAN 13 6

14 - 20 4

21 - 26 3

27 - 33 2

34 - 41 1

42 - 52 1/0

53 - 66 2/0

67 - 84 3/0

106 - 125 4/0

126 - 150 250 KCMIL

126 - 150 300 KCMIL

151 - 175 350 KCMIL

176 - 250 500 KCMIL

251 - 300 600 KCMIL

TBB

PET

TEBC

RBG

ENTRANCE

DUCTS

EQUIPMENT RACK

TR 110

TELECOMMUNICATIONS ROOM

EQUIPMENT RACK

NETWORK

SWITCH

NETWORK

SWITCH

EQUIPMENT RACK

TGB

CABLE TRAY BONDING SYSTEM

ROOM

POWER

PANEL

RBG

TEBC

1 2 3 4 5

A

B

C

D

PLATE REFERENCE

NUMBER

SHEET OF

P L

O T

D A

T E

P

L O

T S

C A

L E

S U

B M

IT

T

E D

B Y

D W

N B

Y

D E

S

IG

N E

D B

Y

C K

D B

Y

D A

T E

S

IZ

E E

F

IL

E N

A M

E

"X

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

C A

T E

G O

R Y

C O

D E

US ARMY CORPS

OF ENGINEERS

PHILADELPHIA

DISTRICT

D O

V E

R A

IR

F

O R

C E

B A

S E

A

IR

C R

A F

T M

A

IN

T E

N A

N C

E F

A C

IL

IT

Y

A S

N O

T E

D

-0

-0

W

B U

- 1 -R

-0

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S

1 2 3 4 5

/1

/2

:0

:4

P M

T-601

T E

L E

C O

M M

U N

IC

A

T

IO

N S

D

IA

G R

A M

S

D K

B R

M S

M V

R T

A

D

E C

D

E C

GENERAL NOTES

1. SEE DWG T-001 FOR TELECOMMUNICATIONS

NOTES, SYMBOLS, AND ABBREVIATIONS.

2. ALL ELECTRICAL EQUIPMENT, WAP AND PA

SPEAKERS, IN THE HANGAR BAY IS REQUIRED TO

BE IN A NEMA 250 TYPE 3R OR WEATHER PROOF

ENCLOSURE.

SCALE: NTST-601

2 PA SYSTEM RISER DIAGRAM

T-601

SCALE: NTST-601

3 TELECOMMUNICATIONS RISER DIAGRAM

T-601SCALE: NTST-601

1 GROUNDING DIAGRAM

T-601

KEYNOTES

1. BELDEN 6T00UP 2C SPEAKER CABLE INSTALLED IN

1" CONDUIT SYSTEM.

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

T-001 - TELECOMMUNICATIONS - NOTES, SYMBOLS, AND ABBREVIATIONS
TS101 - TELECOMMUNICATIONS - SITE UTILITY PLAN
TS102 - TELECOMMUNICATIONS - SITE UTILITY PLAN
T-110 - TELECOMMUNICATIONS - FLOOR PLAN - COMPREHENSIVE
T-111 - TELECOMMUNICATIONS - FLOOR PLAN - AREA A
T-112 - TELECOMMUNICATIONS - FLOOR PLAN - AREA B
T-113 - TELECOMMUNICATIONS - FLOOR PLAN - AREA C
T-114 - TELECOMMUNICATIONS - FLOOR PLAN - AREA D
T-115 - TELECOMMUNICATIONS - FLOOR PLAN - AREA E
T-401 - TELECOMMUNICATIONS ENLARGED PLANS
T-501 - TELECOMMUNICATIONS DETAILS
T-502 - TELECOMMUNICATIONS DETAILS
T-503 - TELECOMMUNICATIONS DETAILS
T-601 - TELECOMMUNICATIONS DIAGRAMS

File details come from the government source that posted it. Updated .