D_Tel11.pdf
PDF 2 MB Posted
- Solicitation number
- W912BU-18-R-0026
About this file
This solicitation is for construction services for an Aircraft Maintenance Hangar at Dover Air Force Base, Delaware. The project includes construction of an 84,176 square foot hangar with office spaces, tool rooms, break room, toilet facilities and support spaces. Related site work includes roads, utilities and optional parking areas. The facility requires enhanced commissioning and LEED Silver certification. The firm-fixed price contract value is between $25-100 million with a 610 calendar day performance period. Proposals are due on April 5, 2019. The contract will be awarded using the tradeoff source selection process based on technical and price factors. A site visit is scheduled for March 1, 2019 for interested firms to examine the project location.
Drawings - 11
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 18R0026_Specs-AM2.pdf | ||
| 18R0026_Dwgs-AM2.pdf | ||
| 18-R-0026_DAFB_AMH_Pre-proposal_Site_Visit_Attendance_Roster.pdf | ||
| 18R0026_Specs-AM1R1.pdf | ||
| D_Elec10.pdf | ||
| D_Civ2.pdf | ||
| D_Structural4.pdf | ||
| RFI_Format.pdf | ||
| D_Civ3.pdf | ||
| D_Int6.pdf | ||
| D_Fire7.pdf | ||
| D_Arch5.pdf | ||
| 18R0026-SpecsVol1-RTA.pdf | ||
| D_Plum8.pdf | ||
| D_Gen1.pdf | ||
| D_Mech9.pdf | ||
| 18R0026-SpecsVol3-RTA.pdf | ||
| 18R0026-SpecsVol2-RTA.pdf |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TELECOMMUNICATIONS HORIZONTAL CABLING
SYSTEM DESIGNATION CABLE TYPE CABLE COLOR
DATA CAT 6 U/UTP BLUE
TELECOMMUNICATIONS BACKBONE CABLING
SYSTEM DESIGNATION CABLE TYPE
DATA OPTICAL FIBER 12- STRAND SM
TELECOMMUNICATIONS STANDARDS
TELECOMMUNICATIONS CABLING NOTES
VOICE MULTI-PAIR ISP VOICE GRADE
VOICE CAT 6 U/UTP WHITE
SYMBOL TELECOMMUNICATIONS DESCRIPTION
110 110 PUNCHDOWN BLOCKS, RACK OR WALL MOUNTED AS INDICATED
8P8C 8-PIN, 8-CONDUCTOR
ACS ACCESS CONTROL SYSTEM
AFF ABOVE FINISHED FLOOR
AHJ AUTHORITY HAVING JURISDICTION
AWG AMERICAN WIRE GAUGE
BCO BASE COMMUNICATIONS OFFICER
BCT BONDING CONDUCTOR FOR TELECOMMUNICATIONS
C CONDUIT(S)
CAA CONTROLLED ACCESS AREA
CAT 6 CABLING ETL VERIFIED TO ANSI/TIA-568-C.2 CATEGORY 6
CATV CABLE TELEVISION
CCH CLOSET CONNECTOR HOUSING
CCTV CLOSED-CIRCUIT TELEVISION
CFCI CONTRACTOR FURNISHED CONTRACTOR INSTALLED
CP CONSOLIDATION POINT
DB DIRECT BURIED
DDC DIRECT DIGITAL CONTROL
DIA DIAMETER
DWG DRAWING
ER EXISTING RELOCATED
ETR EXISTING TO REMAIN
EXIST EXISTING
FB FLOOR BOX
FT FEET
GFGI GOVERNMENT FURNISHED GOVERNMENT INSTALLED
GND GROUND
GRS GALVANIZED RIGID STEEL
IAW IN ACCORDANCE WITH
ICT INFORMATION AND COMMUNICATIONS TECHNOLOGY
IDS INTRUSION DETECTION SYSTEM
IN INCHES
LCA LIMITED CONTROL ACCESS
MC MECHANICAL CONTRACTOR
MIN MINIMUM
MTD MOUNTED
NEC NETWORK ENTERPRISE CENTER
NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
NESC NATIONAL ELECTRICAL SAFETY CODE
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OEM ORIGINAL EQUIPMENT MANUFACTURER
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OFOI OWNER FURNISHED OWNER INSTALLED
OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION
PA PUBLIC ADDRESS
PE POLYETHYLENE
PET PROTECTED ENTRANCE TERMINALS
POTS PLAIN OLD TELEPHONE SERVICE (SWITCHED TELEPHONE LINE)
PSI POUNDS PER SQUARE INCH
PTZ PAN / TILT / ZOOM
QTY QUANTITY
RR REMOVE AND RELOCATE
RS RIGID STEEL
RU RACK UNIT
SCH SCHEDULE
STP SHIELDED TWISTED PAIR
TBB TELECOMMUNICATIONS BONDING BACKBONE
TE TELECOMMUNICATIONS ENCLOSURE
TGB TELECOMMUNICATIONS GROUNDING BUSBAR
TMGB TELECOMMUNICATIONS MAIN GROUNDING BUSBAR
TYP TYPICAL
U/G UNDERGROUND
UON UNLESS OTHERWISE NOTED
U/UTP UNSCREENED/UNSHIELDED TWISTED PAIR CABLE
VoIP VOICE OVER INTERNET PROTOCOL
WP WEATHERPROOF
XP EXPLOSION PROOF
TELECOMMUNICATIONS ABBREVIATIONSTELECOMMUNICATIONS GENERAL NOTES
1. THIS IS A STANDARD LEGEND SHEET. NOT ALL SYMBOLS OR ABBREVIATIONS
MAY APPEAR ON DRAWINGS.
2. REFER TO DIVISIONS 26, 27, 28 AND 33 SPECIFICATIONS FOR
TELECOMMUNICATION SYSTEM ITEMS.
3. MOUNTING DEVICES AND EQUIPMENT PER SPECIFICATIONS UNLESS
OTHERWISE NOTED.
4. MOUNTING HEIGHTS, UNLESS OTHERWISE NOTED, ARE TO CENTER LINE OF
DEVICE.
5. THE CONTRACTOR SHALL DETERMINE THE EXACT ROUTING OF RACEWAYS.
6. THE CONTRACTOR SHALL COORDINATE ALL RACEWAY PENETRATIONS AND
PROVIDE FIREPROOFING AS APPLICABLE.
7. THE MAXIMUM PERMANENT HORIZONTAL LINK DISTANCE SHALL NOT EXCEED
295' AND THE MAXIMUM HORIZONTAL CHANNEL (LINK PLUS WORKSTATION
CABLES AND PATCH CORDS) SHALL BE 328'.
8. ALL HORIZONTAL VOICE AND DATA CABLING SHALL BE CATEGORY-6
INSTALLED IN A MINIMUM 1" CONDUIT UNLESS NOTED OTHERWISE FROM
TELECOMM OUTLET LOCATIONS TO THE CABLE TRAY.
9. ALL HORIZONTAL AND BACKBONE CABLING SHALL BE PLENUM RATED WITH
THE EXCEPTION OF CABLING INSTALLED IN UNDERGROUND CONDUITS. SEE
NOTE 21 FOR CABLES INSTALLED IN UNDERGROUND CONDUITS.
10. CATEGORY-6 CABLING SHALL BE TERMINATED ON 8-PIN, 8-CONDUCTOR (RJ-
45) CONNECTORS USING PIN/PAIR ASSIGNMENTS IN ACCORDANCE WITH T568B
PIN-OUT SEQUENCE.
11. CATEGORY-6 JACKS SHALL BE THE SAME COLOR AS CORRESPONDING
HORIZONTAL VOICE AND DATA CABLING. CATEGORY-6 JACKS SHALL BE THE
SAME MANUFACTURER AS THE PATCH PANELS.
12. PROVIDE CATEGORY-6, 8-PIN, 8-CONDUCTOR MODULAR TO 8-PIN, 8-
CONDUCTOR MODULAR, PATCH CABLES IN QUANTITIES AND LENGTHS SUCH
THAT ALL WORKSTATION CABLES ARE CONNECTED.
13. OPTICAL FIBER CABLES SHALL BE TERMINATED WITH DUPLEX LC-TYPE
CONNECTORS.
14. THE USE OF J-HOOKS SHALL BE LIMITED. WHEN USED, J-HOOKS SHALL BE
CATEGORY-6 RATED AND SPACES AT INTERVALS NOT TO EXCEED 5'. J-HOOKS
SHALL NOT EXCEED 24 CABLES OR 50% FILL, WHICHEVER IS LESS. WHEN J-
HOOKS ARE USED TO SPAN FROM CONDUIT STUB UPS TO CABLE TRAY, A
BONDING BUSHING SHALL BE INSTALLED ON THE CONDUIT STUB UPS AND A
MINIMUM #6 AWG GROUND CONDUCTOR SHALL BE INSTALLED FROM THE
BONDING BUSHING TO THE CABLE TRAY, EFFECTIVELY BONDING THE
METALLIC RACEWAYS TOGETHER.
15. ALL TELECOMMUNICATIONS RACKS AND SUPPORTING STRUCTURES (CABLE
TRAYS, LADDER RACKS, CONDUITS, AND BASKETS) WITHIN A TR MUST BE
BONDED TO THE TR SIGNAL GROUND RING OR BUS BAR (TGB OR TMGB) AS
DEFINED IN ANSI/TIA-569-C AND IN ANSI/TIA-607-B.
16. CABLE TRAY SHALL BE WALL MOUNTED (PREFERABLE) OR TRAPEZE
MOUNTED. CENTER HUNG CABLE TRAY IS NOT ALLOWED. CABLE TRAY SHALL
NOT BE USED TO SUPPORT OTHER ITEMS, CONDUIT, CABLE TRAY, PIPING OF
UTILITIES. CABLE TRAY SUPPORTS SHALL BE PER NEMA STANDARDS
PUBLICATION VE 2 - METAL CABLE TRAY INSTALLATION GUIDELINES.
17. PROVIDE ACCESS PANELS IN NON LAY-IN CEILINGS SUCH THAT NO POINT IN
THE CABLE TRAY SYSTEM IS MORE THAN 20' FROM AN ACCESS POINT.
18. PROVIDE A MINIMUM OF 12" OF CLEARANCE ABOVE THE TOP OF CABLE TRAYS
AND A MINIMUM OF 3" CLEARANCE BELOW CABLE TRAYS.
19. COMPLY WITH ANSI/TIA-569-C TELECOMMUNICATION PATHWAYS AND SPACES.
20. USE ONLY COPPER CONDUCTORS FOR GROUND CONNECTIONS. THE USE OF
ALUMINUM CONDUCTORS IS NOT ALLOWED.
21. PROVIDE CABLE INSTALLED IN UNDERGROUND CONDUITS LISTED FOR USE IN
WET LOCATIONS. PLENUM RATED CABLE SHALL NOT BE INSTALLED IN ANY
UNDERGROUND CONDUIT.
22. LABEL ALL CABLE TERMINATIONS AND BOTH ENDS OF ALL CABLES IN
ACCORDANCE WITH UFC 3-580-01 AND ANSI/TIA-606-B.
23. PROVIDE AS-BUILT DOCUMENTATION INCLUDING COMPLETE TEST RESULT
REPORTS, FLOOR PLANS SHOWING USER WORKSTATIONS WITH CABLING
LABELING, AND BACKBONE CABLE SCHEMATIC AND LABELING IN AN
ELECTRONIC FORMAT (PDF) OR OTHER APPROVED FORMAT AND A PRINTED
HARDCOPY. TEST RESULTS SHALL BE SUPPLIED ELECTRONICALLY TO THE
PROJECT RCDD AND CORPS PROJECT ENGINEER/ARCHITECT IN THE TEST
PROGRAM NATIVE FORMAT.
24. ANY MOTOR, TRANSFORMER, OR OTHER ELECTRICAL DEVICE GREATER THAN
5 KVA SHALL HAVE A MINIMUM OF A 4' BUFFER FROM ANY WALL OF THE EF,
TER, OR TR(S).
25. THE PUBLIC ADDRESS (PA) SYSTEM, WITH COVERAGE TO ALL INTERIOR AREAS
OF THE FACILITY, SHALL INTERFACE WITH THE TELEPHONE SYSTEM SUCH
THAT THE TELEPHONE SYSTEM PROVIDES ACCESS TO THE PA SYSTEM. ALL
PA SPEAKERS SHALL BE WEATHER PROOF IN ACCORDANCE WITH (I.A.W.) UFC
4-211-01 3-6.19.5.1. THE PA SYSTEM SHALL PROVIDE MASS NOTIFICATION
FUNCTION THROUGHOUT THE SUPPORT AREAS AND HANGAR BAY IN I.A.W.
NFPA 72, UFC 4-021-01, UFC 4-021-01, UFC 4-211-01, AND UFC 3-600-01 C1. THE
MASS NOTIFICATION SYSTEM ANNOUNCEMENTS SHALL TAKE PRIORITY OVER
ALL OTHER AUDIBLE ANNOUNCEMENTS OF THE SYSTEM INCLUDING THE
OUTPUT OF THE FIRE ALARM SYSTEM IN A NORMAL OR ALARM STATE. WHEN A
MASS NOTIFICATION ANNOUNCEMENT IS ACTIVATED DURING A FIRE ALARM,
ALL FIRE ALARM SYSTEM FUNCTIONS SHALL CONTINUE IN AN ALARM STATE
EXCEPT FOR THE OUTPUT SIGNALS OF THE FIRE ALARM AUDIBLE AND VISUAL
NOTIFICATION APPLIANCES.
26. EXISTING CONDITIONS AND DEMOLITIONS ARE SHOWN IN THE CIVIL V-SERIES
DRAWINGS.
27. METALLIC TELECOMMUNICATIONS CABLE TRAY RACEWAYS SHOULD BE MADE
ELECTRICALLY CONTINUOUS TO ENSURE PROPER GROUNDING (EARTHING) OF
ALL METALLIC PARTS AND UNITS TO MINIMIZE THE ACCUMULATION OF
VOLTAGES. A MINIMUM OF A 6 AWG INSULATED, STRANDED COPPER, BONDING
CONDUCTOR SHALL BE INSTALLED BETWEEN THE METALIC
TELECOMMUNICATIONS CABLE TRAY TRANSITIONING TO PVC CONDUIT
RACEWAY EFFECTIVELY BONDING THE METALLIC RACEWAYS TOGETHER.
ANSI/TIA 607-C STANDARD PROVIDES ADDITIONAL GUIDANCE FOR SPECIFIC
BONDING CONDUCTOR SIZE VS LENGTH.
COORDINATE ALL CABLE COLORS WITH AHJ BEFORE PURCHASE.
TELECOMMUNICATIONS INSTALLATION SHALL COMPLY WITH THE MOST
CURRENT VERSION OF THE FOLLOWING STANDARDS:
ANSI/TIA-568-C.2, 2009 - BALANCED TWISTED-PAIR TELECOMMUNICATIONS
CABLING AND COMPONENTS STANDARD
ANSI/TIA-568-C.3, 2008 - OPTICAL FIBER CABLING COMPONENTS STANDARD
ANSI/TIA-568-C.4, 2011 - BROADBAND COAXIAL CABLING AND COMPONENTS
STANDARD
ANSI/TIA-568-D.0, 2015 - GENERIC TELECOMMUNICATIONS CABLING FOR
CUSTOMER PREMISES
ANSI/TIA-568-D.1, 2015 - COMMERCIAL BUILDING TELECOMMUNICATIONS
CABLING STANDARD
ANSI/TIA-569-D, 2015 - TELECOMMUNICATIONS PATHWAYS AND SPACES
ANSI/TIA/EIA-598-C - OPTICAL FIBER CABLE COLOR CODING.
ANSI/TIA-606-B, 2012 - ADMINISTRATION STANDARD FOR COMMERCIAL
TELECOMMUNICATIONS INFRASTRUCTURE
ANSI/TIA-607-B, 2011 - COMMERCIAL BUILDING GROUNDING (EARTHING) AND
BONDING REQUIREMENTS FOR TELECOMMUNICATIONS
ANSI/TIA-758-B, 2012 - CUSTOMER-OWNED OUTSIDE PLANT
TELECOMMUNICATIONS INFRASTRUCTURE STANDARD
ANSI/TIA-1152, 2009 - REQUIREMENTS FOR FIELD TEST INSTRUMENTS AND
MEASUREMENTS FOR BALANCED TWISTED-PAIR CABLING
TIA-526-7 (OFSTP-7)-2002+A1:2008 - MEASUREMENT OF OPTICAL POWER LOSS OF
INSTALLED SINGLE-MODE FIBER CABLE PLANT
TIA-526-14-B-2010 (OFSTP-14) - OPTICAL POWER LOSS MEASUREMENTS OF
INSTALLED MULTIMODE FIBER CABLE PLANT
TIA-758 - CUSTOMER-OWNED OUTSIDE PLANT TELECOMMUNICATIONS
INFRASTRUCTURE
TSB-162-A - TIA SYSTEMS BULLETIN TELECOMMUNICATIONS CABLING
GUIDELINES FOR WIRELESS ACCESS POINTS
IEC/TR 61602 ED. 1.0 B:1996 27-JUN-1996 CONNECTORS USED IN THE FIELD OF
AUDIO, VIDEO AND AUDIOVISUAL ENGINEERING
IEC 61883-1 ED. 3.0 EN:2008 07-FEB-2008 CONSUMER AUDIO/VIDEO EQUIPMENT -
DIGITAL INTERFACE - PART 1: GENERAL
IEC 61883-6 ED. 2.0 EN:2005 28-OCT-2005 CONSUMER AUDIO/VIDEO EQUIPMENT -
DIGITAL INTERFACE - PART 6: AUDIO AND MUSIC DATA TRANSMISSION
PROTOCOL
IEC 61938 ED. 1.0 B:1996 05-DEC-1996 AUDIO, VIDEO AND AUDIOVISUAL SYSTEMS
- INTERCONNECTIONS AND MATCHING VALUES – PREFERRED MATCHING
VALUES OF ANALOGUE SIGNALS
IEC 62075 ED. 1.0 B:2008 15-JAN-2008 AUDIO/VIDEO, INFORMATION AND
COMMUNICATION TECHNOLOGY EQUIPMENT – ENVIRONMENTALLY CONSCIOUS
DESIGN
IEC 62087-BD ED. 2.0 EN:2008 15-OCT-2008 METHODS OF MEASUREMENT FOR
THE POWER CONSUMPTION OF AUDIO, VIDEO AND RELATED EQUIPMENT
UFC-3-580-01 CA - TELECOMMUNICATIONS INTERIOR INFRASTRUCTURE
PLANNING AND DESIGN
UFGS 27.10.00 - BUILDING TELECOMMUNICATIONS CABLING SYSTEM
MIL-HDBK-419A – GROUNDING, BONDING, AND SHIELDING FOR ELECTRONIC
EQUIPMENT AND FACILITIES
MIL-HDBK-1012/3 - TELECOMMUNICATIONS PREMISES DISTRIBUTION PLANNING,
DESIGN, AND ESTIMATING
NFPA 262 - STANDARD METHOD OF TEST FOR FLAME TRAVEL AND SMOKE OF
WIRES AND CABLES FOR USE IN AIR-HANDLING SPACES
NFPA 70 - NATIONAL ELECTRICAL CODE (NEC)
NFPA 75 - STANDARD FOR THE PROTECTION OF INFORMATION TECHNOLOGY
EQUIPMENT
NFPA 76 - STANDARD FOR THE FIRE PROTECTION OF TELECOMMUNICATIONS
FACILITIES
NFPA 780 - STANDARD FOR THE INSTALLATION OF LIGHTNING PROTECTION
SYSTEMS
AR 380-5 - DEPARTMENT OF THE ARMY INFORMATION SECURITY PROGRAM
AMERICANS WITH DISABILITIES ACT AND ARCHITECTURAL BARRIERS ACT
ACCESSIBILITY GUIDELINES (UFAS/ADAAG), 2011
BICSI - BUILDING INDUSTRIES CONSULTING SERVICES INTERNATIONAL (TDMM),
13TH ED., 2014, TELECOMMUNICATIONS DISTRIBUTION METHODS MANUAL 13TH
EDITION.
TERMINATIONS SHALL BE PERFORMED USING PIN/PAIR ASSIGNMENTS IN
ACCORDANCE WITH THE T568B PIN-OUT SEQUENCE USING 8-PIN 8
CONDUCTOR (8P8C) RJ45 TYPE CONNECTORS RATED FOR THE CATEGORY OF
THE INSTALLED CABLE; COLOR SHALL MATCH THE U/UTP OUTER JACKET.
TELECOMMUNICATIONS OUTLETS, 8P8C RJ45 TYPE CONNECTOR
· U/UTP CABLES FOR DATA SHALL HAVE A BLUE OUTER JACKET
· U/UTP CABLES FOR VOICE SHALL HAVE A WHITE OUTER JACKET
CATV OUTLET WITH ONE RG-6 COAXIAL CABLE AND ONE F-TYPE
CONNECTOR, MOUNTED AT 72" AFF
1 STANDARD DUPLEX ICT OUTLET WITH THREE (3) CATEGORY-6
U/UTP CABLE, TWO (2) LABELED DATA AND ONE (1) LABELED
VOICE - CENTER OF OUTLET MOUNTED AT 18" AFF
X = DENOTES (MUTOA) MULTI-USER TELECOMMUNICATIONS
OUTLET ASSEMBLY WHERE (X) DEPICTS THE NUMBER OF
DUPLEX OUTLET CONNECTOR AGGREGATE OF TWO (2)
LABELED DATA AND ONE (1) LABELED VOICE
W
TV
VOICE-ONLY OUTLET - ONE OUTLET CONNECTOR IN A SINGLE
GANG OUTLET FACEPLATE WITH MOUNTING LUGS - MOUNTED AT
57" AFF; WP DESIGNATES "WEATHERPROOF" FOR OUTSIDE
BUILDING ENTRANCES
APPLICABLE TO ALL OUTLETS LISTED BELOW:
X
WP
CATV BROADBAND INDOOR DISTRIBUTION AMPLIFIER
CATV SYMBOLS:
8-WAY SPLITTER
TERMINATION
CONTINUANCE
1 DATA, DIRECT DIGITAL CONTROL (DDC) SYSTEM IT OUTLET,
CENTER OF OUTLET MOUNTED AT 18” AFF
DDC
SYMBOL TELECOMMUNICATIONS DESCRIPTION
WAP WIRELESS ACCESS POINT OUTLET (2 CATEGORY-6 U/UTP
OUTLETS), LOCATED 12" ABOVE DROPPED CEILING
PA
GROUNDING BUSBAR, TMGB OR TGB AS INDICATED ON PLANS
CABLE TRAY, SIZE AS INDICATED ON PLANS. WELDED WIRE TYPE
FOR DISTRIBUTION OF CABLING OUTSIDE OF TELECOMMUNICATION
ROOMS AND LADDER TYPE CABLE RUNWAY WITHIN
TELECOMMUNICATION ROOMS
WEATHERPROOF CEILING MOUNTED PA SYSTEM SPEAKER
19" TELECOMMUNICATIONS EQUIPMENT RACK
VERTICAL UPWARD CONDUIT FROM UNDERGROUND OSP
OTHER SYMBOLS:
HORIZONTAL CONDUIT RUN FROM TELECOMMUNICATION
ROOMS TO RESPECTIVE AREAS AS INDICATED ON PLANS
CRASH PHONE - ONE OUTLET CONNECTOR IN A SINGLE GANG
OUTLET FACEPLATE WITH MOUNTING LUGS - MOUNTED AT 57" AFF;
EP DESIGNATES DEDICATED EMERGENCY WALL MOUNTED PRIVATE
LINE TELEPHONE PROVISIONED FOR AUTOMATIC RING-DOWN TO
THE FIRE DEPARTMENT. LOCATION AND LOGISTICS SHALL BE
COORDINATED WITH THE FIRE DEPARTMENT.
EP
PA WEATHERPROOF WALL MOUNTED PA SYSTEM HORN SPEAKER
MOUNTED AT 15'0" AFF.
1 STANDARD TRIPLEX ICT OUTLET WITH FOUR (4) CATEGORY-6
U/UTP CABLE, THREE (3) LABELED DATA AND ONE (1) LABELED
VOICE - CENTER OF OUTLET MOUNTED AT 18" AFF
X = DENOTES (MUTOA) MULTI-USER TELECOMMUNICATIONS
OUTLET ASSEMBLY WHERE (X) DEPICTS THE NUMBER OF
DUPLEX OUTLET CONNECTOR AGGREGATE OF THREE (3)
LABELED DATA AND ONE (1) LABELED VOICE
TXT
HDMI CONNECTOR
AV
SITE TELECOMMUNICATIONS
Cux EXISTING COMMUNICATION UNDERGOUND CONDUITS TO REMAIN
COMMUNICATIONS MANHOLE - CMH
Cu NEW DIRECT BURIED PVC SCHEDULE 40 CONDUITS
COMMUNICATIONS HANDHOLE - CHH
EXISTING COMMUNICATION UNDERGROUND CONDUITS TO BE DEMOLISHEDCux
SYMBOL
C
CM
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
1 2 3 4 5
/1
/2
:0
:2
P M
T-001
T E
L E
C O
M M
U N
IC
A
T
IO
N S
N
O T
E S
, S Y
M B
O L
S A
N D
A B
B R
E V
IA
T
IO
N
S
D K
B R
M S
M V
R T
A
D
E C
D
E C
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
A
B
S c
922 W WWE S
TT T TTTJC T S
c c
S
S c
SS
J C TGEN
DN
VAN
TS101
TS102
CM
CMCux Cux
Cux Cux
C u
C u
C
Cu
Cu
Cu
Cu Cu
TS101T-502
Cu
CM
C u
C uCM
Cux
Cux
Cu Cu
Cu Cu
Cu Cu
Cu Cu
C u
C u
C u
C u
C u
C u
C u
C u
C
C ux
Cux
MH-913-2 Cu x
Cu x
Cux Cux
(1) 4" PVC
(1) 4" PVC
(1) 4" PVC
Cux Cux Cux
(1) 4" PVC
HH-14
(1) 4" PVC
(2) 4" PVC
60SM, B711-B910
6SM, 910-C2
HH-105
(2) 4" PVC
6PR, 22AWG
36SM FIBER
918-711
(2) 4" PVC
60SM, B77-910
6SM, 910-C2
AIP COPPER
(2) 4" PVC
(2) 4" PVC
Cu
Cu
Cu
Cux
PNN
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
1 2 3 4 5
/1
/2
:0
:5
P M
TS101
T E
L E
C O
M M
U N
IC
A
T
IO
N S
S
IT
E
U T
IL
IT
Y P
L A
N
D K
B L
A K
M V
R T
A
D
E C
D
E C
KEY PLAN
SCALE:
10'-0" 20'-0" 40'-0"
0'-1" = 20'-0"
GENERAL NOTES
1. SEE DWG T-001 FOR TELECOMMUNICATIONS
NOTES, SYMBOLS, AND ABBREVIATIONS.
2. COMMUNICATIONS MANHOLES HAVE INTERIOR
DIMENSIONS OF 4’ X 4’ X4’ AND NEED TO MATCH
THE SPECIFICATIONS OF THOSE INSTALLED ON
THE BASE. THE APPROVED COMMUNICATIONS
MANHOLES ARE EQUIPPED WITH FOUR (4) “PAI”
MOLDED PULLING IRONS, A 12” DIAMETER X 4”
DEEP SUMP, AND ONE (1) GROUND ROD
KNOCKOUT. THE TOP HAS A 30” ACCESS OPENING.
THEY MUST HAVE THE LOCK DOWN/LOCK DRY
MECHANISM KEYED THE SAME AS ALL
COMMUNICATIONS MANHOLES INSTALLED ON THE
BASE. THE BASE COMMUNICATIONS OFFICER’S
OFFICE (BCO) CAN PROVIDE THE LOCKS FOR THE
LOCK DOWN/LOCK DRY MECHANISMS. THE
MECHANISMS THEMSELVES ARE CONTRACTOR
FURNISHED AND CONTRACTOR INSTALLED.
3. COMMUNICATIONS HANDHOLES ARE 2’ X 3’,
COMPOSITE, WITH NON-LOCKING LIDS.
4. PLEASE COORDINATE WITH THE BCO.
5. THREE (3) CATEGORY-6 OUTSIDE PLANT RATED
U/UTP CABLES INSTALLED INTO THE 3" CONDUIT
TO THE TRANSFORMER PAD FOR DDC. EACH
PASSING THROUGH A CATEGORY-6 DATA LINE
NETWORK SURGE PROTECTOR MODULE
LOCATED IN TER 100 PRIOR TO THE NETWORK
SWITCH. TERMINATE EACH U/UTP CABLE ONTO AN
8P8C RJ45-TYPE JACK, RATED FOR OUTDOOR
INSTALLATION, INSTALLED INTO A NEMA-4X
OUTLET ENCLOSURE AT THE TRANSFORMER PAD.
COORDINATE WITH ELECTRICAL.
LEGEND
Cux
EXISTING COMMUNICATION UNDERGOUND
CONDUITS TO REMAIN
COMMUNICATIONS MANHOLE - CMHCM
Cu NEW DIRECT BURIED PVC SCHEDULE 40
CONDUITS
COMMUNICATIONS HANDHOLE - CHHC
KEYNOTES
1. PROVIDE FOUR (4) 4-INCH PVC SCHEDULE 40
CONDUITS. THREE (3) CONDUIT SHALL INCLUDE
THREE (3) 3-INCH 3-CELL FABRIC MESH
INNERDUCT TOTALING NINE INNNERDUCTS PER
CONDUIT. ONE (1) CONDUIT SHALL BE DEDICATED
FOR ONE (1) 24-STRAND SINGLE MODE FIBER
OPTICAL CABLE. ONE (1) OPEN CONDUIT (NO
INNERDUCT) SHALL BE DEDICATED FOR ONE (1)
100-PAIR OSP UTP COPPER CABLE. TWO (2)
CONDUIT (WITH INNERDUCT) SHALL BE
DEDICATED FOR SPARES.
2. EXISTING TO REMAIN.
3. ABANDONED IN PLACE.
4. ONE (1) 3" CONDUIT INSTALLED BETWEEN TER
100 TO THE TRANSFORMER PAD LOCATED AT
THE SOUTHWEST CORNER OF THE HANGAR
BUILDING.
EXISTING COMMUNICATION UNDERGROUND
CONDUITS TO BE DEMOLISHED
Cux
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
A
B
S c
922 W WWE S
TT T TTTJC T S
c c
S
S c
SS
J C TGEN
DN
VAN
C u
C u
C u
C u
C u
C u
C u
C u
CuCu
CuCu
Cu Cu
Cu Cu
Cu Cu
Cu Cu
Cu Cu
CM Cu Cu
C ux
C ux
C ux
C u
CM
C u
CM
CM
C u
C u
C u
C u
C u
C u
CM C
C ux
C ux
C ux
C ux
C ux
C ux
C u
C u
C u
C u
C ux
DIRECT BURIED
COPPER
HH-26
(1) 4" PVC
(1) 4" PVC
(4) 4" PVC
(4) 4" PVC
MH-91060SM, B910-877
6SM, B910-CAMERA2
36SM,
B639-B910
CM
CM
(1) 4" PVC W/ MAXCEL
BLOWN FIBER FOR
CAMERAS AT MUNITIONS
C ux
C ux
C ux
Cux
Cux Cux
Cux
Cux
36SM,
B639-B910
36SM,
B639-B910
60SM, B910-877
6SM, B910-CAMERA2
60SM, B910-877
6SM, B910-CAMERA2
60SM, B910-877
6SM, B910-CAMERA2
(2) 4" PVC
(2) 4" PVC
AIP COPPER
T
Cu
Cu
TS101
TS102
PNN
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
1 2 3 4 5
/1
/2
:0
:0
P M
TS102
T E
L E
C O
M M
U N
IC
A
T
IO
N S
S
IT
E
U T
IL
IT
Y P
L A
N
D K
B L
A K
M V
R T
A
D
E C
D
E C
KEY PLAN
SCALE:
10'-0" 20'-0" 40'-0"
0'-1" = 20'-0"
GENERAL NOTES
1. SEE DWG T-001 FOR TELECOMMUNICATIONS
NOTES, SYMBOLS, AND ABBREVIATIONS.
2. COMMUNICATIONS MANHOLES HAVE INTERIOR
DIMENSIONS OF 4’ X 4’ X4’ AND NEED TO MATCH
THE SPECIFICATIONS OF THOSE INSTALLED ON
THE BASE. THE APPROVED COMMUNICATIONS
MANHOLES ARE EQUIPPED WITH FOUR (4) “PAI”
MOLDED PULLING IRONS, A 12” DIAMETER X 4”
DEEP SUMP, AND ONE (1) GROUND ROD
KNOCKOUT. THE TOP HAS A 30” ACCESS OPENING.
THEY MUST HAVE THE LOCK DOWN/LOCK DRY
MECHANISM KEYED THE SAME AS ALL
COMMUNICATIONS MANHOLES INSTALLED ON THE
BASE. THE BASE COMMUNICATIONS OFFICER’S
OFFICE (BCO) CAN PROVIDE THE LOCKS FOR THE
LOCK DOWN/LOCK DRY MECHANISMS. THE
MECHANISMS THEMSELVES ARE CONTRACTOR
FURNISHED AND CONTRACTOR INSTALLED.
3. COMMUNICATIONS HANDHOLES ARE 2’ X 3’,
COMPOSITE, WITH NON-LOCKING LIDS.
4. PLEASE COORDINATE WITH THE BCO.
5. THREE (3) CATEGORY-6 OUTSIDE PLANT RATED
U/UTP CABLES INSTALLED INTO THE 3" CONDUIT
TO THE TRANSFORMER PAD FOR DDC. EACH
PASSING THROUGH A CATEGORY-6 DATA LINE
NETWORK SURGE PROTECTOR MODULE
LOCATED IN TER 100 PRIOR TO THE NETWORK
SWITCH. TERMINATE EACH U/UTP CABLE ONTO AN
8P8C RJ45-TYPE JACK, RATED FOR OUTDOOR
INSTALLATION, INSTALLED INTO A NEMA-4X
OUTLET ENCLOSURE AT THE TRANSFORMER PAD.
COORDINATE WITH ELECTRICAL.
LEGEND
Cux
EXISTING COMMUNICATION UNDERGOUND
CONDUITS TO REMAIN
COMMUNICATIONS MANHOLE - CMHCM
Cu NEW DIRECT BURIED PVC SCHEDULE 40
CONDUITS
COMMUNICATIONS HANDHOLE - CHHC
KEYNOTES
1. PROVIDE FOUR (4) 4-INCH PVC SCHEDULE 40
CONDUITS. THREE (3) CONDUIT SHALL INCLUDE
THREE (3) 3-INCH 3-CELL FABRIC MESH
INNERDUCT TOTALING NINE INNNERDUCTS PER
CONDUIT. ONE (1) CONDUIT SHALL BE DEDICATED
FOR ONE (1) 24-STRAND SINGLE MODE FIBER
OPTICAL CABLE. ONE (1) OPEN CONDUIT (NO
INNERDUCT) SHALL BE DEDICATED FOR ONE (1)
100-PAIR OSP UTP COPPER CABLE. TWO (2)
CONDUIT (WITH INNERDUCT) SHALL BE
DEDICATED FOR SPARES.
2. EXISTING TO REMAIN.
3. ABANDONED IN PLACE.
4. ONE (1) 3" CONDUIT INSTALLED BETWEEN TER
100 TO THE TRANSFORMER PAD LOCATED AT
THE SOUTHWEST CORNER OF THE HANGAR
BUILDING.
EXISTING COMMUNICATION UNDERGROUND
CONDUITS TO BE DEMOLISHED
Cux
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
W
P W
A P
W A
P W
A P
W A
P W
A P
W A
P W
A P
W A
P
W A
P
WAP
WAP
WAP
WAP
WAP
TV TV
TV TV
A V
WAP WAP
EPEP
W W
W
W
T
T
T D
D C
T W
W W
W
W
W
W
W
W
W
W
W
W
PA
PA
PA
PA PA PA
PA
PA PA
PA
PA
PA PA
PA
PA
PA
PA
P A
PA PA
PA PA
PA
PA
P A
PA
P A
P A
P A
P A
P A
P A P
A
P A
P A
P A
W
T T
T T
T
W
P A
P A
P A
W
W
T
A V
D D
C
PA
P
A
P A
PA
PA
PA
PAPA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
DDC
A
B
C
D
E
F
G
H
J
K
L
M
N
M.1
0.0 0.2 0.9 1 2 3 4 5 5.2 6.2 7 7.8 8.8 9 10 11 1312
TOOL CRIB
FUEL
CELL
TOOL
ROOM
ELEC
MECHANICAL ROOM
RESTROOM WOMEN'S
G003
HALLWAY
C001
MENS LOCKER RM
G006
MECH
TER
LOBBY
L001
RESTROOM
G002
VESTIBULE
V001
J.C.
G001
CORRIDOR
C002
BREAKROOM
OFFICE
OFFICE
OPEN
OFFICE
WOMENS
LOCKER
RM
G005
RESTROOM MEN'S
G004
/1 T-111
/1 T-113
/1 T-112
/1 T-114
/1 T-111
/1 T-113
/1 T-112
/1 T-114
/1 T-113
/1 T-115
/1 T-114
T -1
T -1
FIRE
PUMP
AND
FOAM
TANK
ROOM
TR
ELECTRICAL
ROOM
EQUIP CLOSET
104A
HANGAR
PNN
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
A B
C D
E
KEY PLAN
1 2 3 4 5
/1
/2
:0
:3
P M
T-110
T E
L E
C O
M M
U N
IC
A
T
IO
N S
F
L O
O R
P L
A N
C
O M
P R
E H
E N
S
IV
E
D K
B R
M S
M V
R T
A
D
E C
D
E C
SCALE: 1/16" = 1'-0"
TELECOMMUNICATIONS - FLOOR PLAN - COMPREHENSIVE
GENERAL NOTES
1. SEE DWG T-001 FOR TELECOMMUNICATIONS
NOTES, SYMBOLS, AND ABBREVIATIONS.
SCALE:
8'-0" 16'-0" 32'-0"
0'-0 1/16" = 1'-0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
P
W A P
WAP
WAP
WAP
TV TV
TV TV
A V
T
T
T
T
W W
W W
W
W
W
PA
PA
PA
PA PA
PA
PA
PA
P A
P A
T T
T T
T
T
A V
PA
PA
PA
PAPA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
PA
T-111 T-401
RESTROOM WOMEN'S
G003
HALLWAY
C001
TER
A
B
C
D
E
0.0 0.2 0.9 1 2 3 4 5 5.2 6.2 7
LOBBY
L001
RESTROOM
G002
VESTIBULE
V001
J.C.
G001
BREAKROOM
OFFICE
OFFICE
OPEN OFFICE
WOMENS LOCKER RM
G005
RESTROOM MEN'S
G004
/1 T-113 /1 T-113
/1 T-112
/1 T-114
T -1
EQUIP CLOSET
104A
2 2
2 2
HANGAR
PNN
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
A B
C D
E
KEY PLAN
1 2 3 4 5
/1
/2
:0
:4
P M
T-111
T E
L E
C O
M M
U N
IC
A
T
IO
N S
F
L O
O R
P L
A N
A
R E
A A
D K
B R
M S
M V
R T
A
D
E C
D
E C
SCALE: 1/8" = 1'-0"T-111
1 TELECOMMUNICATIONS - FLOOR PLAN - AREA A
SCALE:
4'-0" 8'-0" 16'-0"
0'-0 1/8" = 1'-0"
GENERAL NOTES
1. SEE DWG T-001 FOR TELECOMMUNICATIONS
NOTES, SYMBOLS, AND ABBREVIATIONS.
2. EACH WIRELESS ACCESS POINT (WAP) OUTLET
SHALL BE MOUNTED AT 12-INCHES ABOVE
FINISHED CEILING, EXCEPT IN THE HANGAR BAY
AREAS.
3. WIRELESS ACCESS POINT (WAP) OUTLET IN THE
HANGAR BAY AREAS SHALL BE WALL-MOUNTED
AT 11'-0" AFF.
4. ALL ELECTRICAL EQUIPMENT, WAP AND PA
SPEAKERS, IN THE HANGAR BAY IS REQUIRED TO
BE IN A NEMA 250 TYPE 3R OR WEATHER PROOF
ENCLOSURE.
KEYNOTES
1. A FLAT SCREEN DIGITAL SIGNAGE MONITOR
SHALL BE LOCATED IN THE MAIN HALLWAY NEAR
THE MAIN ENTRY. CONTENT SHALL BE
CONTROLLED BY A LOCAL DIGITAL SIGNAGE
APPLIANCE TO BE LOCATED AT A DESK IN THE
ADMIN AREA. HDMI CONNECTIVITY BETWEEN
THESE TWO WITH ONE (1) HDMI CONNECTOR AT
THE MONITOR AND ONE (1) HDMI CONNECTOR AT
THE DESK WITH THE DIGITAL SIGNAGE
APPLIANCE.
2. FLAT SCREEN TELEVISIONS IN BREAKROOM 104
SHALL EACH HAVE ONE (1) CATV RF COAXIAL
CONNECTOR.
3. THREE (3) 4-INCH SCH. 40 PVC CONDUITS WITH
THREE (3) THREE-CELL FABRIC MESH INNER-
DUCTS INSTALLED IN EACH CONDUIT INSTALLED
BETWEEN THE EF/TER, ROOM 100, AND THE TR,
ROOM 110, ROUTED BENEATH THE FLOOR SLAB.
REFERENCE DETAIL 4 ON DRAWING T-502.
4. PROVIDE 12X4 CABLE TRAY.
5. ONE (1) HDMI CONNECTOR FOR THE DIGITAL
SIGNAGE APPLIANCE WITH ONE (1) HDMI CABLE
TO THE HDMI CONNECTOR AT THE DIGITAL
SIGNAGE MONITOR.
T-110
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
P
W A P
W P A
P A
A
B
C
D
E
7 7.8 8.8 9 10 11 1312
/1 T-114
/1 T-111
/1 T-113 /1 T-114
T -1
HANGAR
PNN
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
A B
C D
E
KEY PLAN
1 2 3 4 5
/1
/2
:0
:4
P M
T-112
T E
L E
C O
M M
U N
IC
A
T
IO
N S
F
L O
O R
P L
A N
A
R E
A B
D K
B R
M S
M V
R T
A
D
E C
D
E C
SCALE: 1/8" = 1'-0"T-112
1 TELECOMMUNICATIONS - FLOOR PLAN - AREA B
GENERAL NOTES
1. SEE DWG T-001 FOR TELECOMMUNICATIONS
NOTES, SYMBOLS, AND ABBREVIATIONS.
2. WIRELESS ACCESS POINT (WAP) OUTLET IN THE
HANGAR BAY AREAS SHALL BE WALL-MOUNTED
AT 11'-0" AFF.
3. ALL ELECTRICAL EQUIPMENT, WAP AND PA
SPEAKERS, IN THE HANGAR BAY IS REQUIRED TO
BE IN A NEMA 250 TYPE 3R OR WEATHER PROOF
ENCLOSURE.
SCALE:
4'-0" 8'-0" 16'-0"
0'-0 1/8" = 1'-0"
T-110
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
P W
A P
WAP
WAP
WAP
EP EP
W W
D D
C W
W
PA
PA PA PA
PA
PA PA
PA
PA
PA
P A
PA
P A
P A
P A
P A
P A
P A
P A
P A
W
DDC
TOOL CRIB
FUEL CELL TOOL ROOM
ELEC
MECHANICAL ROOM
MENS LOCKER RM
G006
HANGAR
F
G
H
J
K
0.0 0.2 0.9 1 2 3 4 5 5.2 6.2 7
CORRIDOR
C002
RESTROOM MEN'S
G004
/1 T-111 /1 T-111 /1 T-112
/1 T-114
/1 T-115
/1 T-114
PNN
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
A B
C D
E
KEY PLAN
1 2 3 4 5
/1
/2
:0
:5
P M
T-113
T E
L E
C O
M M
U N
IC
A
T
IO
N S
F
L O
O R
P L
A N
A
R E
A C
D K
B R
M S
M V
R T
A
D
E C
D
E C
SCALE: 1/8" = 1'-0"T-113
1 TELECOMMUNICATIONS - FLOOR PLAN - AREA C
GENERAL NOTES
KEYNOTES
1. SEE DWG T-001 FOR TELECOMMUNICATIONS
NOTES, SYMBOLS, AND ABBREVIATIONS.
2. WIRELESS ACCESS POINT (WAP) OUTLET IN THE
HANGAR BAY AREAS SHALL BE WALL-MOUNTED
AT 11'-0" AFF.
3. ALL ELECTRICAL EQUIPMENT, WAP AND PA
SPEAKERS, IN THE HANGAR BAY IS REQUIRED TO
BE IN A NEMA 250 TYPE 3R OR WEATHER PROOF
ENCLOSURE.
SCALE:
4'-0" 8'-0" 16'-0"
0'-0 1/8" = 1'-0"
1. THREE (3) 4-INCH SCH. 40 PVC CONDUITS WITH
THREE (3) THREE-CELL FABRIC MESH INNER-
DUCTS INSTALLED IN EACH CONDUIT INSTALLED
BETWEEN THE EF/TER, ROOM 100, AND THE TR,
ROOM 110, ROUTED BENEATH THE FLOOR SLAB.
REFERENCE DETAIL 4 ON DRAWING T-502.
2. CRASH PHONES: ONE SHALL BE RED IN COLOR
AND THE OTHER BLUE IN COLOR.
3. COORDINATE WITH MECHANICAL FOR DDC
LOCATION.
4. PROVIDE TWO (2) 4-INCH PVC CONDUITS.
5. PROVIDE 12X4 CABLE TRAY.
T-110
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
P
W A P
WAPPA
W P A
W
PA
T-114 T-401
HANGAR
F
G
H
J
K
7 7.8 8.8 9 10 11 1312
/1 T-112/1 T-111
/1 T-113
/1 T-112
/1 T-113
/1 T-115
TR
ELECTRICAL
ROOM
PNN
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
A B
C D
E
KEY PLAN
1 2 3 4 5
/1
/2
:0
:0
P M
T-114
T E
L E
C O
M M
U N
IC
A
T
IO
N S
F
L O
O R
P L
A N
A
R E
A D
D K
B R
M S
M V
R T
A
D
E C
D
E C
SCALE: 1/8" = 1'-0"T-114
1 TELECOMMUNICATIONS - FLOOR PLAN - AREA D
GENERAL NOTES
KEYNOTES
1. SEE DWG T-001 FOR TELECOMMUNICATIONS NOTES,
SYMBOLS, AND ABBREVIATIONS.
2. WIRELESS ACCESS POINT (WAP) OUTLET IN THE
HANGAR BAY AREAS SHALL BE WALL-MOUNTED AT 11'-
0" AFF.
3. ALL ELECTRICAL EQUIPMENT, WAP AND PA SPEAKERS,
IN THE HANGAR BAY IS REQUIRED TO BE IN A NEMA 250
TYPE 3R OR WEATHER PROOF ENCLOSURE.
SCALE:
4'-0" 8'-0" 16'-0"
0'-0 1/8" = 1'-0"
1. THREE (3) 4-INCH SCH. 40 PVC CONDUITS WITH
THREE (3) THREE-CELL FABRIC MESH INNER-
DUCTS INSTALLED IN EACH CONDUIT INSTALLED
BETWEEN THE EF/TER, ROOM 100, AND THE TR,
ROOM 110, ROUTED BENEATH THE FLOOR SLAB.
REFERENCE DETAIL 4 ON DRAWING T-502.
T-110
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
P
W A P
W
W
W
W
W
PA PA
PA
PA
P A
PA
W
D D C
PA
P A
T-114 T-401
MECH
K
L
M
N
M.1
5 5.2 6.2 7 7.8 8.8 9 10 11 1312
/1 T-113 /1 T-114
FIRE PUMP AND FOAM
TANK ROOM
TR
ELECTRICAL
ROOM
PNN
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
A B
C D
E
KEY PLAN
1 2 3 4 5
/1
/2
:0
:0
P M
T-115
T E
L E
C O
M M
U N
IC
A
T
IO
N S
F
L O
O R
P L
A N
A
R E
A E
D K
B R
M S
M V
R T
A
D
E C
D
E C
SCALE: 1/8" = 1'-0"T-115
1 TELECOMMUNICATIONS - FLOOR PLAN - AREA E
GENERAL NOTES
KEYNOTES
1. SEE DWG T-001 FOR TELECOMMUNICATIONS
NOTES, SYMBOLS, AND ABBREVIATIONS.
2. WIRELESS ACCESS POINT (WAP) OUTLET IN THE
HANGAR BAY AREAS SHALL BE WALL-MOUNTED
AT 11'-0" AFF.
3. ALL ELECTRICAL EQUIPMENT, WAP AND PA
SPEAKERS, IN THE HANGAR BAY IS REQUIRED TO
BE IN A NEMA 250 TYPE 3R OR WEATHER PROOF
ENCLOSURE.
SCALE:
4'-0" 8'-0" 16'-0"
0'-0 1/8" = 1'-0"
1. THREE (3) 4-INCH SCH. 40 PVC CONDUITS WITH
THREE (3) THREE-CELL FABRIC MESH INNER-
DUCTS INSTALLED IN EACH CONDUIT INSTALLED
BETWEEN THE EF/TER, ROOM 100, AND THE TR,
ROOM 110, ROUTED BENEATH THE FLOOR SLAB.
T-110
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
P
A
W P
A
TER
(TYP) 1
2 4 5 6
TR
(TYP)
TGB5
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
1 2 3 4 5
/1
/2
:0
:1
P M
T-401
T E
L E
C O
M M
U N
IC
A
T
IO
N S
E N
L A
R G
E D
P L
A N
S
D K
B R
M S
M V
R T
A
D
E C
D
E C
SCALE: 1/4" = 1'-0"T-111 T-401
1 TELECOMMUNICATIONS - ENLARGED TER RM 100
SCALE: 1/4" = 1'-0"T-114 T-401
2 TELECOMMUNICATIONS - ENLARGED TR RM 110
SCALE:
2'-0" 4'-0" 8'-0"
0'-0 1/4" = 1'-0"
GENERAL NOTES
KEYNOTES
1. SEE DWG T-001 FOR TELECOMMUNICATIONS
NOTES, SYMBOLS, AND ABBREVIATIONS.
2. WIRELESS ACCESS POINT (WAP) OUTLET IN THE
HANGAR BAY AREAS SHALL BE WALL-MOUNTED AT
11'-0" AFF.
3. THREE (3) CATEGORY-6 OUTSIDE PLANT RATED
U/UTP CABLES INSTALLED INTO THE 3" CONDUIT TO
THE TRANSFORMER PAD FOR DDC. EACH PASSING
THROUGH A CATEGORY-6 DATA LINE NETWORK
SURGE PROTECTOR MODULE LOCATED IN TER 100
PRIOR TO THE NETWORK SWITCH. TERMINATE
EACH U/UTP CABLE ONTO AN 8P8C RJ45-TYPE
JACK, RATED FOR OUTDOOR INSTALLATION,
INSTALLED INTO A NEMA-4X OUTLET ENCLOSURE
AT THE TRANSFORMER PAD. COORDINATE WITH
ELECTRICAL.
1. 8' HIGH x 3/4" THICK, AC GRADE, VOID FREE, FIRE
RATED PLYWOOD BACKBOARD COVERING THREE
WALLS. DO NOT PAINT. PLYWOOD IS TO BE
INSTALLED 8" AFF.
2. FOUR (4) 4" CONDUITS FROM OSP. CONDUITS ARE
TO BE STUBBED UP 4"-6" AFF.
3. TELECOMMUNICATIONS MAIN GROUNDING
BUSBAR (TMGB); 1/4" THICK X 24" LONG X 4" WIDE,
MOUNTED AT 78" AFF; SEE DETAIL 1 ON DWG T-502.
4. BUILDING ENTRANCE TERMINAL (BET).
5. WALL-MOUNTED, 110-TYPE CONNECTOR BLOCKS
WITH C-5 CLIPS FOR COPPER BACKBONE
TERMINATIONS.
6. CATV BROADBAND INDOOR DISTRIBUTION
AMPLIFIER.
7. WALL-MOUNTED PHONE OUTLET WITH ONE (1)
CATEGORY 6 CABLE MOUNTED AT 57" AFF.
8. THREE (3) 4" CONDUITS FROM TER 100 TO TR 110.
9. ONE (1) 2" CONDUIT EXTENDED TO FIVE (5) FEET
PAST BUILDING FOR CATV SERVICE PROVIDER.
10. ONE (1) 3" CONDUIT INSTALLED BETWEEN TER 100
TO THE TRANSFORMER PAD LOCATED AT THE
SOUTHWEST CORNER OF THE HANGER BUILDING.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
MODULAR RJ45
CONNECTOR
1" CONDUIT
(MINIMUM)
4" H x 2 1/8" W x 2 1/8" D
OUTLET BOX WITH
SINGLE GANG
PLASTER RING
DDC
MOUNTING LUGS
MODULAR RJ45
CONNECTOR
W
1" CONDUIT
(MINIMUM)
4" H x 2 1/8" W x 2 1/8" D
OUTLET BOX WITH SINGLE
GANG PLASTER RING.
MOUNTED AT 57" AFF
EP
F-TYPE
CONNECTOR
TV
1" CONDUIT
(MINIMUM)
4" H x 2 1/8" W x 2 1/8" D
OUTLET BOX WITH SINGLE
GANG PLASTER RING.
MOUNTED AT 72" AFF
DATA
MODULAR RJ45
CONNECTOR
1" CONDUIT
(MINIMUM)
5" SQUARE x 2 7/8"
DEEP OUTLET BOX
WITH SINGLE GANG
PLASTER RING
BLANK COVER
DATA
MODULAR RJ45
CONNECTOR
VOICE
MODULAR RJ45
CONNECTOR
1" CONDUIT
(MINIMUM)
5" SQUARE x 2 7/8"
DEEP OUTLET BOX
WITH SINGLE GANG
PLASTER RING
DATA
MODULAR RJ45
CONNECTOR
DATA
MODULAR RJ45
CONNECTOR
VOICE
MODULAR RJ45
CONNECTOR
DATA
MODULAR RJ45
CONNECTOR
T
CABLE TRAY
INSULATED GROUND BUSHING
WITH #6 AWG CONDUCTOR TO
CABLE TRAY BONDING
CONDUCTOR
1" CONDUIT
CABLE TRAY
CONDUIT
CLAMP
1' -0
0'
-3
TELECOMM WALL
OUTLET BOX
SEE DETAILS 1 - 4
OF T-501 FOR
OUTLET DETAILS.
MIN. CLEARANCE
MIN.
CEILING
1/4"
HOLE (TYP)
TELECOMMUNICATIONS MAIN GROUNDING BUSBAR (TMGB) AT THE EF/TER, IN ACCORDANCE WITH ANSI/TIA-607-C, SERVES AS THE DEDICATED EXTENSION OF THE BUILDING AC GROUNDING (EARTHING) ELECTRODE SYSTEM FOR THE TELECOMMUNICATIONS INFRASTRUCTURE. IT SERVES AS THE CENTRAL ATTACHMENT POINT FOR THE
TELECOMMUNICATIONS BONDING BACKBONE (TBB) AND TELECOMMUNICATIONS EQUIPMENT.
THE WALL MOUNTED TMGB MUST BE A PREDRILLED WITH STANDARD 5/16" HOLES IN A 2 HOLE CONFIGURATION, OF COPPER OR A COPPER ALLOY WITH A MINIMUM OF 95% CONDUCTIVITY, BE ELECTROTIN0PLATED (ETP) TO REDUCE CONTACT RESISTANCE AND CORROSION, WITH MINIMUM DIMENSIONS OF 0.25 INCH THICKNESS BY 4
INCH WIDTH AND BE A MINIMUM OF 24 INCHES IN LENGTH.
THE TMGB IS BONDED TO THE MAIN ELECTRICAL SERVICE GROUNDING ELECTRODE SYSTEM AT THE MAIN SWITCHBOARD WITH A BONDING CONDUCTOR FOR TELECOMMUNICATIONS (BCT) CONDUCTOR USING
IRREVERSIBLE, HIGH COMPRESSION OR PERMANENT EXOTHERMIC CONNECTIONS.
4"
24"
(TYP)
(TYP)
ICT RACK 1 ICT RACK 2
(TYP) (TYP)(TYP)
(TYP)
(TYP) (TYP)
(TYP)
(TYP)
ICT RACK
(TYP REAR)
INDIVIDUAL EQUIPMENT
GROUNDING TERMINAL
(TYP)
TECB
10 13
1/4"
HOLE (TYP)
TELECOMMUNICATIONS GROUNDING BUSBAR (TGB) IN THE TELECOMMUNICATIONS SPACES, IN
ACCORDANCE WITH ANSI/TIA-607-B, IS THE GROUNDING (EARTHING) CONNECTION POINT FOR
TELECOMMUNICATIONS INFRASTRUCTURE SYSTEMS (E.G., CABLING, PATHWAYS) AND
TELECOMMUNICATIONS EQUIPMENT IN THE AREA SERVED BY A TER OR A TR.
THE WALL MOUNTED TGB MUST BE A PREDRILLED WITH STANDARD 5/16" HOLES IN A 2 HOLE
CONFIGURATION, OF COPPER OR A COPPER ALLOY WITH A MINIMUM OF 95% CONDUCTIVITY, BE
ELECTROTIN0PLATED (ETP) TO REDUCE CONTACT RESISTANCE AND CORROSION, WITH MINIMUM
DIMENSIONS OF 0.25 INCH THICKNESS BY 2 INCH WIDTH AND BE A MINIMUM OF 24 INCHES IN LENGTH.
THE TGB SHALL BE BONDED TO THE TMGB AND TO THE MAIN ELECTRICAL SERVICE GROUNDING ELECTRODE
SYSTEM WITH A BONDING CONDUCTOR FOR TELECOMMUNICATIONS (BCT) CONDUCTOR USING
IRREVERSIBLE, HIGH COMPRESSION OR PERMANENT EXOTHERMIC CONNECTIONS AND BE BONDED TO THE NEAREST STRUCTURAL STEEL MEMBER, WHETHER IT IS A HORIZONTAL OR VERTICAL BEAM, IF AVAILABLE.
2"
24"
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
1 2 3 4 5
/1
/2
:0
:2
P M
T-501
T E
L E
C O
M M
U N
IC
A
T
IO
N S
D E
T A
IL
S
D K
B R
M S
M V
R T
A
D
E C
D
E C
SCALE: NTST-501
1 TYPICAL DDC OUTLET
T-501 SCALE: NTST-501
4 TYPICAL WALL PHONE OUTLET
T-501
SCALE: NTST-501
5 TYPICAL CATV OUTLET
T-501
SCALE: NTST-501
2 TYPICAL DUPLEX ICT OUTLET
T-501 SCALE: NTST-501
3 TYPICAL TRIPLEX ICT OUTLET
T-501
SCALE: NTST-501
11 CABLE TRAY TO OUTLET CONDUIT TRANSITION
T-501SCALE: NTST-501
TELECOMMUNICATIONS MAIN GROUNDING
BUSBAR, TMGB
T-501
SCALE: NTST-501
8 TYPICAL RGB ENLARGED DETAIL
T-501SCALE: NTST-501
6 EQUIPMENT RACK ELEVATIONS
T-501 SCALE: NTST-501
7 TYPICAL EQUIPMENT RACK REAR VIEW
T-501
GENERAL NOTES
KEYNOTES
1. SEE DWG T-001 FOR TELECOMMUNICATIONS
NOTES, SYMBOLS, AND ABBREVIATIONS.
SCALE: NTST-501
TELECOMMUNICATIONS GROUNDING BUSBAR,
TGB
T-501
1. 7'H X 6"W X 14.61"D DOUBLE SIDED, DOUBLE
HINGED VERTICAL WIRE MANAGERS.
2. 7'H X 20.3"W TWO-POST 19-INCH EQUIPMENT
RACK WITH 6" VERTICAL WIRE MANAGERS AND
RMU MARKINGS FOR SUPPORT UP TO 1500 LB
STATIC LOAD RATING.
3. 2 RU HORIZONTAL WIRE MANAGEMENT UNIT.
4. 48 PORT, 2 RU, CATEGORY 6, PATCH PANELS
FOR HORIZONTAL CABLES WITH T568A WIRING
FOR 110 STYLE IDC TERMINATIONS.
5. CFCI 7"H X 19"W X 17"D RACK-MOUNTED
CORNING CLOSET CONNECTOR HOUSING (CCH)
FOR DUPLEX SC ADAPTERS, FOR 12-SM OS2
FIBERS; PART NUMBER CCH-04U; HOLDS 12
CCH PANELS AND IS 4RU; SPECIFICALLY USED
IN TER 124 FOR TERMINATING BACKBONE
CABLE FROM EF AND TO TR 106 AND TR 126.
6. LADDER TYPE, CABLE RUNWAY, MADE UP OF
STEEL TUBING WITH CROSS MEMBERS WELDED
AT 12" INTERVALS.
7. CABLE RUNWAY ELEVATION BRACKETS WITH A
4-6" STAND-OFF FROM THE TOP OF THE
EQUIPMENT RACK.
8. CABLE RUNWAY RADIUS DROP, MOUNTS TO
RUNWAY CROSS MEMBER.
9. 24-PORT, 1 RU POTS PATCH PANEL.
10. L5-20R TWIST LOCK RECEPTACLE MOUNTED ON
THE CABLE TRAY ABOVE TELECOM RACK.
11. 1 INCH X 19 INCH RACK MOUNTED RGB
LOCATED 1 RU FROM THE TOP, BONDED TO
TGB. REFERENCE DETAIL 5 OF T-603.
12. STANDARD RACK HARDWARE.
13. L6-20R TWIST LOCK RECEPTACLE MOUNTED ON
THE CABLE TRAY ABOVE TELECOM RACK.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
RGS OR IMC BUSHING
RGS/IMC CONDUIT EXTENDED UP
TO EQUIPMENT AS DIRECTED ON
CONSTRUCTION DRAWINGS
FINISHED FLOOR
RGS/IMC SWEEP. SIZE TO MATCH RGS/IMC
CONDUIT. SWEEP RADIUS TO BE
CONSISTENT WITH DEPTH OF BURIED
RGS/IMC CONDUIT
4" TO
6" AFF
CUT PVC CONDUIT AND ATTACH A
THREADED / COMPRESSION RGS/IMC
ADAPTOR OR FITTING AS REQUIRED
UNDERGROUND PVC CONDUIT
NOTE:
NON METALLIC CONDUIT, OTHER THAN PVC SCH 40 OR 80 SHALL BE CONVERTED
TO PLASTIC COATED RIGID, OR IMC, STEEL CONDUIT BEFORE RISING THROUGH
THE FLOOR SLAB WITH APPROPRIATE SWEEPS AND COUPLINGS.
GROUNDING BUSHING4" TO 6" AFF.
FIRE-RATED A-C PLYWOOD
BACKBOARD (SEE NOTE BELOW)
NOTE:
RIDIGLY-FIXED FIRE-RATED, 3/4" A-C PLYWOOD BACKBOARD, PREFERABLY VOID-FREE
WITH THE A-SIDE OUT, INSTALLED 6" AFF TO 8'-6" AFF, CAPABLE F SUPPORTING
ATTACHED EQUIPMENT. THE FIRE STAMP SHALL BE CLEARLY VISIBLE, DO NOT PAINT.
RF CABLE FROM CATV
SERVICE PROVIDER
COAXIAL CABLE
GROUNDING BLOCK
CATV DISTRIBUTION
AMPLIFIER
8-WAY CATV SPLITTER, BLONDER
TONGUE MODEL SDS-8 OR
APPROVED EQUIVALENT, WALL
MOUNTED, CONNECTING ALL RG6
COAXIAL DISTRIBUTION CABLE.
FINAL GRADE
MARKING12
M
IN
SELECTED BACKFILL
(NO STONES OVER
3" DIAMETER)
(2) - 4" CONDUIT WITH
(3) - 3" - 3 CELL FABRIC
MESH INNERDUCT
CONCRETE
M
IN
1'-10" MIN
AROUND)
3"
(TYP ALL
2" MIN
2' -0 M
IN
SPARE
FINAL GRADE
MARKING12
M
IN
SELECTED BACKFILL
(NO STONES OVER
3" DIAMETER)
(3) - 4" CONDUIT WITH
(3) - 3" - 3 CELL FABRIC
MESH INNERDUCT
CONCRETE
M
IN
2'-4" MIN
AROUND)
3"
(TYP ALL
2" MIN
2' -0 M
IN
SPARE
STRUT CHANNELLADDER RACK HOLD DOWN
CLAMP WITH HEX
HEAD BOLT & STRUT
CHANNEL NUT
10mm THREADED ROD
FLAT
WASHER
AND NUT
LADDER RACK
SINGLE POINT
BRACKET
LOCK
WASHER
AND NUT
10mm THREADED ROD
LADDER RACK
ELEVATION KIT
480mm
TELECOM
M
RACK
LADDER RACK
(AS SHOWN ON PLANS)
LADDER RACK HOLD
DOWN CLAMP WITH HEX
HEAD BOLT & STRUT
CHANNEL NUT
SPACE SUPPORTS ACCORDING TO CABLE TRAY
WORKING LOAD RATING AND CABLE TRAY
MANUFACTURER RECOMMENDATIONS. FIRST
SUPPORT MUST BE WITHIN 300mm OF SPLICE WITH
A MAXIMUM OF ONE SPLICE BETWEEN SUPPORTS.
UNISTRUT CHANNEL
AND BRACING
SURFACE MOUNTED
PLATE
1. SURFACE MOUNTED CHANNEL MUST BE SECURELY FASTENED
INTO THE SLAB, WALL, ETC. SUFFICIENTLY TO CARRY THE LOAD
OF THE TRAY AND ITS CONTENTS WITH A SAFETY FACTOR OF 3.
2. ALL CHANNEL, TRAY FITTINGS AND ACCESSORIES ARE TO BE
GALVANIZED.
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
1 2 3 4 5
/1
/2
:0
:2
P M
T-502
T E
L E
C O
M M
U N
IC
A
T
IO
N S
D E
T A
IL
S
D K
B R
M S
M V
R T
A
D
E C
D
E C
SCALE: NTST-502
1 PVC TO RGS OR IMC CONDUIT STUB UP DETAIL
T-502 SCALE: NTST-502
4" ENTRANCE RGS CONDUIT WITH GROUNDING
BUSHING
T-502 SCALE: NTST-502
3 CATV SYSTEM BACKBOARD ELEVATION
T-502
SCALE: NTST-502
TELECOMMUNICATIONS 3-WAY CONCRETE
ENCASED DUCT BANK
T-502 SCALE: NTST-502
TELECOMMUNICATIONS 4-WAY CONCRETE
ENCASED DUCT BANK
T-502
GENERAL NOTES
1. SEE DWG T-001 FOR TELECOMMUNICATIONS
NOTES, SYMBOLS, AND ABBREVIATIONS.
SCALE: NTST-502
LADDER TYPE CABLE RUNWAY TRAPEZE
MOUNTING
T-502SCALE: NTST-502
LADDER TYPE CABLE RUNWAY SINGLE POINT
MOUNTING
T-502SCALE: NTST-502
8 LADDER TYPE CABLE RUNWAY RACK MOUNTING
T-502
SCALE: NTST-502
LADDER TYPE CABLE RUNWAY WALL MOUNTING
DETAIL
T-502
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
#6 AWG GROUND WIRE
GROUND LUG
GROUND LUG
FIRE RATED WALL
FIRE RATED SLEEVE
ASSEMBLY
PENETRATIONS
THROUGH WALL FOR
ACCESS
TO CABLE TRAY (TYP)LADDER RACK
(AS SHOWN ON
ENLARGED PLANS)
1. SURFACE MOUNTED CHANNEL MUST BE SECURELY FASTENED
INTO THE SLAB, WALL, ETC. SUFFICIENTLY TO CARRY THE LOAD
OF THE TRAY AND ITS CONTENTS WITH A SAFETY FACTOR OF 3.
2. ALL CHANNEL, TRAY FITTINGS AND ACCESSORIES ARE TO BE
GALVANIZED.
3. ALL METALIC TELECOMMUNICATIONS PATHWAYS SHALL BE
BONDED TO THE TELECOMMUNICATIONS BONDING BUSBAR
INSIDE THE NEAREST TELECOMMUNICATIONS SPACE I.A.W.
ANSI/TIA-607-C (7.1.5).
1/2"
3/8"
9'-0" AFF.
10'-6" AFF.
12'-0" AFF.
500 MCM INSULATED COPPER
EQUIPMENT GROUND
RUNWAY SPLICE 2012
GROUND STRAP
CABLE BRACKET 24" O.C.
SEE NEWTON FIGURE
2052 DETAIL (TYP)
5/8" ALL THREAD ROD WITH P1000
UNISTRUT TRAPEZE OR (NEWTON
3022-11) AS REQUIRED HANGERS
4'-0" O.C. UP TO P-1000 UNISTRUT
INSTALL ON BOTH SIDES OF
CABLE LADDER
RUNWAY BRACKET 3029-1
2-5/8" HEX NUTS 3014-8
LOCK WASHER 3015-8
SAUNDERS SB-156
WASHER SB-1048-A
NUT SB-1028
CABLE LADDER
NEWTON FIGURE 2004-4 + 12"
NEWTON FIGURE 2003-23 + 16"
NEWTON FIGURE 2003-26 + 24"
NEWTON FIGURE 2003-29 + 30"
NEWTON FIGURE 2003-30 + 36"
JUNCTION
KIT 2014
TOP OF
FLOOR SLAB
m m
T Y
P
FINISHED
CEILING SLAB
VERTICAL WALL BRACKETS
(TYP)
610mm WIDE LADDER TYPE
CABLE RUNWAY
INSTALL GROUND WIRE
(GREEN INSULATED) FROM
TRAY TO GROUND BUSBAR IN
COMM AREA. SEE DWG
T-110 FOR BUSBAR LOCATION.
PROTECTIVE END CAPS (TYP)
RUNWAY FOOT KIT (TYP)THREE (3) 4" CONDUITS
(TYP)
COMMUNICATION
1-1/2" SHARP FACE GOTHIC
(4) 1" HANDLING HOLES ON 35-1/2" BC
(2) CLOSED PICKHOLES
1040A SQ 1-1/2" PH CORE
CORE# 10402010
32" DIA
0' -1
/2
32-1/4" DIA
30" DIA
32-1/4" DIA
38" DIA
ACM PART NUMBER 141983
NOTE: FRAME IS REVERSIBLE.
CAN BE INSTALLED AS A TOP
FLANGE UNIT.
2'-6"
5'-0"
2' -6
5' -0
(4) 1" DIA THREADED
PENNSYLVANIA INSERT
CORPORATION
STEPDOWN (TYP) APPLY
JOINT SEALANT BEFORE
INSTALLING TO PIECE
BELOW
30" DIA ACCESS OPENING
0' -6
0'
-0
/4
3'-11"
0'-6 1/2"
0'-6"
0' -6
2'-0"
4'-0"
2' -0
4' -0
FLAT SURFACE FOR CONNECTION
JOINT SEALANT BEFORE
INSTALLATION
(4) 38-1/2" H x 45" W x 3" D
KNOCKOUT
(4) PAI MOLDED
PULLING IRON
12" DIA x 4" DEEP SUMP
WITH A 1" GROOVE
1" DIA GROUND ROD
KNOCKOUT
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y : C
K D
B Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
1 2 3 4 5
/1
/2
:4
:4
P M
T-503
T E
L E
C O
M M
U N
IC
A
T
IO
N S
D E
T A
IL
S
D K
B R
M S
M V
R T
A
D
E C
D
E C
GENERAL NOTES
1. SEE DWG T-001 FOR TELECOMMUNICATIONS
NOTES, SYMBOLS, AND ABBREVIATIONS.
SCALE: NTST-503
RE-ENTERABLE MECHANICAL FIRESTOP
ASSEMBLY CABLE TRAY TO LADDER RACK WALL
PENETRATION
T-503 SCALE: NTST-503
LADDER TYPE CABLE RUNWAY WALL MOUNTING
DETAIL
T-503 SCALE: NTST-503
VERTICAL TELECOMMUNICATIONS CABLE
RUNWAY
T-503
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
SCALE: NTST-503
4 MANHOLE COVER
T-503 SCALE: NTST-503
5 MANHOLE
T-503 SCALE: NTST-503
6 HANDHOLE
T-503
EJC T
PA
FROM PBX
FXO PORT
PUBLIC ADDRESS SINGLE-ZONE TELEPHONE INTERFACE DEVICE
SUCH AS THE BOGEN MODEL UTI1
DIGITAL FEEDBACK TERMINATOR
SUCH AS THE BOGEN MODEL DFT120
PUBLIC ADDRESS AMPLIFIER
SUCH AS THE BOGEN MODEL M600
TER 100
HANGAR 105ADMIN AND SUPPORT AREA
PA PA PA
(TYP) (TYP) (TYP)(TYP)
CEILING OR
WALL MOUNTED
SPEAKERS
WEATHERPROOF
WALL MOUNTED
SPEAKERS
1 11
(TYP)
WALL
PHONE
ICT
OUTLET
(TYP)
STANDARD
DUAL ICT
OUTLET
(TYP)
STANDARD
SINGLE
ICT
OUTLET
PLENUM CATEGORY-6 U/UTP CABLE (TYP)
(TYP)
TELECOMM
HORIZONTAL
EQUIPMENT
RACK
(TYP)
WAP
B U
IL
D
IN
G
M E T A L
S T R
U C
T U
R E A
C C
E S S
IB
LE
TER 100
TELECOMMUNICATIONS EQUIPMENT ROOM
EQUIPMENT RACK
NETWORK
SWITCH
ROOM
POWER
PANEL
TMGB
NETWORK
SWITCH
CABLE TRAY BONDING SYSTEM
ELECTRICAL ROOM 107
GROUNDING
ELECTRODE
SYSTEM
MGB
TBB
ANSI/TIA-607-B TBB CONDUCTOR SIZE CHART
TBB/GE LINEAR LENGTH (FEET) AWG #
LESS THAN 13 6
14 - 20 4
21 - 26 3
27 - 33 2
34 - 41 1
42 - 52 1/0
53 - 66 2/0
67 - 84 3/0
106 - 125 4/0
126 - 150 250 KCMIL
126 - 150 300 KCMIL
151 - 175 350 KCMIL
176 - 250 500 KCMIL
251 - 300 600 KCMIL
TBB
PET
TEBC
RBG
ENTRANCE
DUCTS
EQUIPMENT RACK
TR 110
TELECOMMUNICATIONS ROOM
EQUIPMENT RACK
NETWORK
SWITCH
NETWORK
SWITCH
EQUIPMENT RACK
TGB
CABLE TRAY BONDING SYSTEM
ROOM
POWER
PANEL
RBG
TEBC
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
1 2 3 4 5
/1
/2
:0
:4
P M
T-601
T E
L E
C O
M M
U N
IC
A
T
IO
N S
D
IA
G R
A M
S
D K
B R
M S
M V
R T
A
D
E C
D
E C
GENERAL NOTES
1. SEE DWG T-001 FOR TELECOMMUNICATIONS
NOTES, SYMBOLS, AND ABBREVIATIONS.
2. ALL ELECTRICAL EQUIPMENT, WAP AND PA
SPEAKERS, IN THE HANGAR BAY IS REQUIRED TO
BE IN A NEMA 250 TYPE 3R OR WEATHER PROOF
ENCLOSURE.
SCALE: NTST-601
2 PA SYSTEM RISER DIAGRAM
T-601
SCALE: NTST-601
3 TELECOMMUNICATIONS RISER DIAGRAM
T-601SCALE: NTST-601
1 GROUNDING DIAGRAM
T-601
KEYNOTES
1. BELDEN 6T00UP 2C SPEAKER CABLE INSTALLED IN
1" CONDUIT SYSTEM.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
| T-001 - TELECOMMUNICATIONS - NOTES, SYMBOLS, AND ABBREVIATIONS |
| TS101 - TELECOMMUNICATIONS - SITE UTILITY PLAN |
| TS102 - TELECOMMUNICATIONS - SITE UTILITY PLAN |
| T-110 - TELECOMMUNICATIONS - FLOOR PLAN - COMPREHENSIVE |
| T-111 - TELECOMMUNICATIONS - FLOOR PLAN - AREA A |
| T-112 - TELECOMMUNICATIONS - FLOOR PLAN - AREA B |
| T-113 - TELECOMMUNICATIONS - FLOOR PLAN - AREA C |
| T-114 - TELECOMMUNICATIONS - FLOOR PLAN - AREA D |
| T-115 - TELECOMMUNICATIONS - FLOOR PLAN - AREA E |
| T-401 - TELECOMMUNICATIONS ENLARGED PLANS |
| T-501 - TELECOMMUNICATIONS DETAILS |
| T-502 - TELECOMMUNICATIONS DETAILS |
| T-503 - TELECOMMUNICATIONS DETAILS |
| T-601 - TELECOMMUNICATIONS DIAGRAMS |