D_Int6.pdf
PDF 3 MB Posted
- Solicitation number
- W912BU-18-R-0026
About this file
This document provides details for a federal construction contract opportunity for an Aircraft Maintenance Hangar at Dover Air Force Base in Delaware. The project involves construction of an approximately 84,176 square foot single bay, fully enclosed hangar with office spaces, tool rooms, break room, toilet facilities and support spaces. The contract is a firm-fixed price design-bid-build contract between $25-100 million awarded by the U.S. Army Corps of Engineers, Philadelphia District. The construction duration is anticipated to be approximately 610 calendar days. A site visit is scheduled for March 1, 2019 and requests for information are due by March 19, 2019. Proposals are due April 5, 2019. The contract will be awarded based on a tradeoff process evaluating technical and price factors.
Drawings - 7
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 18R0026_Specs-AM2.pdf | ||
| 18R0026_Dwgs-AM2.pdf | ||
| 18-R-0026_DAFB_AMH_Pre-proposal_Site_Visit_Attendance_Roster.pdf | ||
| 18R0026_Specs-AM1R1.pdf | ||
| D_Elec10.pdf | ||
| D_Civ2.pdf | ||
| D_Structural4.pdf | ||
| RFI_Format.pdf | ||
| D_Civ3.pdf | ||
| D_Fire7.pdf | ||
| D_Arch5.pdf | ||
| D_Tel11.pdf | ||
| 18R0026-SpecsVol1-RTA.pdf | ||
| D_Plum8.pdf | ||
| D_Gen1.pdf | ||
| D_Mech9.pdf | ||
| 18R0026-SpecsVol3-RTA.pdf | ||
| 18R0026-SpecsVol2-RTA.pdf |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
1 2 3 4 5
/1
/2
:4
:1
P M
IN001
IN
T
E R
IO
R
F
IN
IS
H
D E
T A
IL
E
D N
O T
E S
L
E G
E N
D S
S
C H
E D
U L
E S
A L M
R D
T
L J B
R T
A
D
E C
D
E C
NOTES - INTERIOR FINISH
1 SEE TECHNICAL SPECIFICATIONS & INTERIOR FINISH
DRAWINGS FOR INTERIOR FINISH INFORMATION.
2 SEE IN001 FOR INTERIOR MATERIAL COLOR SCHEDULE
& ROOM FINISH SCHEDULE. SEE IN500 FOR
ELEVATIONS & INTERIOR DETAILS.
3 INTERIOR FLOOR PLANS, ENLARGED PLANS AND
ELEVATIONS SHOWN IN THE 'IN' SERIES ARE FOR
FINISH LOCATIONS ONLY. REFER TO ARCHITECTURAL
DRAWINGS FOR DIMENSIONS AND CONSTRUCTION
INFORMATION.
4 MATERIAL FLOOR AND WALL TRANSITIONS ARE TO BE
COORDINATED WITH SELECTED PRODUCTS AND
INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
PROVIDE BARRIER FREE TRANSITIONS AT ALL FLOOR
CHANGES. SEE TRANSITION DETAILS, SERIES IN500,
FOR MORE INFORMATION.
5 REFER TO ARCHITECTURAL PLANS FOR STANDARD
MOUNTING HEIGHTS OF BATHROOM ACCESSORIES
AND FIXTURES. DIMENSIONS PROVIDED IN FINISH
DRAWINGS ARE FOR FINISH EXTENTS ONLY.
6 EXTERIOR WINDOWS RECEIVE WINDOW TREATMENTS,
TYP. U.N.O.. SEE INTERIOR ROOM SCHEDULE &
MATERIAL SCHEDULE FOR TYPES & MATERIALS AS
WELL AS THE WRITTEN SPECIFICATIONS FOR MORE
INFORMATION.
7 METAL GRILLES, DIFFUSERS, PANEL BOXES AND
REGISTERS LOCATED WITHIN OCCUPIED AREAS ARE
PAINTED TO MATCH THE ADJACENT WALL FINISH AS
NOTED ON THE FINISH SCHEDULES AND DRAWINGS.
8 REFER TO INTERIOR FINISH DRAWINGS FOR ACCENT
WALL LOCATIONS / EXTENTS.
9 SEE PLUMBING DRAWINGS FOR RESTROOM FIXTURE
INFORMATION.
10 WINDOWS WIDER THAN 48" REQUIRE MULTIPLE
SHADES PER WINDOW. INDIVIDUAL SHADE WILL NOT
EXCEED 48" IN WIDTH. SHADE DIVISION ARE AT
WINDOW MULLIONS. PROVIDE PROPOSED LAYOUT PER
WINDOW IN SHOP DRAWING SUBMITTAL. PROVIDE
WINDOW HARDWARE AS INDICATED IN
SPECIFICATIONS.
11 CONTROL JOINTS WILL MATCH THE COLOR OF THE
ADJACENT FLOORING MATERIAL.
12 REFER TO ARCHITECTURAL REFLECTED CEILING
PLANS FOR CEILING HEIGHTS.
13 TYPICAL MARKERBOARDS & BULLETIN BOARDS ARE
MOUNTED AT 36" AFF TO BOTTOM OF THE
MARKER/BULLETIN BOARD U.N.O.
14 WOOD GRAIN DIRECTION ON PLASTIC LAMINATE RUNS
VERTICAL.
15 CG1 CORNER GUARDS AT EXPOSED CORNERS IN
CORRIDORS U.N.O. CORNER GUARDS WILL BE
MOUNTED FROM THE TOP OF THE WALL BASE TO 72"
A.F.F
16 PROVIDE NECESSARY WALL BLOCKING FOR MARKER
BOARDS, TACKBOARDS, BULLETIN BOARDS, AND WALL
MOUNTED TVS.
17 SEE IN500 SERIES FOR FLOOR / WALL & WALL / WALL
TRANSITION DETAILS.
18 PROVIDE FLEXIBLE SEALANT AT WALL AND FLOOR
JOINT WHERE THERE IS NO WALL BASE REQUIRED.
19 MECHANICAL EQUIPMENT, SUPPLY & RETURN GRILLES
ETC. ARE SHOWN FOR REFERENCE ONLY. REFER TO
THE M-SERIES DRAWINGS FOR MORE INFORMATION.
SCHEDULE - INTERIOR FINISH - MATERIAL & COLOR BASIS OF DESIGN
FINISH DESCRIPTION MANUFACTURER STYLE COLOR COMMENTS
ACP1 ACOUSTICAL CEILING PANEL ARMSTRONG CIRRUS TEGULAR 584 WHITE 24" x 24" x 3/4"; 15/16" GRID
ACP2 ACOUSTICAL CEILING PANEL ARMSTRONG ULTIMA HEALTHZONE HIGH NRC 1447 WHITE - RESTROOMS 24" x 24" x 7/8"; 15/16" GRID
CG1 CORNER GUARD C/S ACROVYN ACROVYN 4000 SM20AN - 3" CORNER GUARD DRIFTWOOD 262 LOBBY AREA
CT1 CERAMIC TILE DALTILE MODERN DIMENSIONS - 4.25" X 12.75" ARTIC WHITE 0190 1 WALL FIELD TILE
CT2 CERAMIC TILE DALTILE MODERN DIMENSIONS - 2.125" X 8.5" SUEDE GRAY 0182 WALL ACCENT TILE
CT3 CERAMIC TILE DALTILE MODERN DIMENSIONS - 4.25" X 8.5" SUEDE GRAY 0182 WALL ACCENT TILE
CT4 CERAMIC TILE DALTILE SEMI-GLOSS - 6" X 6" NAVY K189 WALL ACCENT TILE
CTB1 WALL BASE TILE DALTILE MODERN DIMENSIONS FLAT TOP COVE BASE A-34C1 ARTIC WHITE 0190 USE AT WALLS WITH CT1 TILES
EF1 EPOXY FLOORING SYSTEM STONHARD STONTEC TRF SMALL FLAKES DIABLO BEIGE ADMIN / BREAKROOM / TOOL ROOMS
GT1 GROUT LATICRETE SPECTRALOCK NATURAL GREY 24 AT FLOOR & WALL TILE
HF1 HANGAR FLOORING SYSTEM TENNANT FUEL RESISTIVE RESIOUS FLOOR SYSTEM - 5 COAT LIGHT GRAY FIELD - HANGAR - SEE SPECIFICATIONS FOR DETAILS
N/A INTERIOR SIGNAGE 2/90 SIGNS N/A DARK GREY 734 BACKGROUND; SOFT WHITE 708 TEXT FIELD
P1 PAINT SHERWIN WILLIAMS LATEX / SATIN GOSSAMER VEIL SW9165 WALLS - FIELD
P2 PAINT SHERWIN WILLIAMS LATEX / SATIN FOGGY DAY SW6235 WALLS ACCENT - OFFICE AREA / BREAK ROOM
P3 PAINT SHERWIN WILLIAMS EPOXY / SEMI-GLOSS GRAYS HARBOR SW6236 INTERIOR HOLLOW METAL DOOR FRAMES / DOORS; FOR
EXTERIOR HM DOOR FRAMES / DOORS REFER TO THE
EXTERIOR FINISH SCHEDULE ON A-200
P4 PAINT SHERWIN WILLIAMS EPOXY / EGGSHELL CEILING BRIGHT WHITE SW7007 CEILINGS - SHOWERS
P5 PAINT SHERWIN WILLIAMS LATEX / EGGSHELL CEILING BRIGHT WHITE SW7007 CEILINGS
P6 PAINT SHERWIN WILLIAMS EPOXY / EGGSHELL GOSSAMER VEIL SW9165 WALLS - JANITOR
PL1 PLASTIC LAMINATE WILSONART LINEARITY FINISH WITH AEON COSMIC STRANDZ 4941K-18 VERTICAL CASEWORK AT BREAKROOM
PL2 PLASTIC LAMINATE NEVAMAR ARMORED PROTECTION VOUS METAL VS6001T RESTROOM COUNTER APRONS
PT1 PORCELAIN TILE DALTILE INDUSTRIAL PARK - 12" X 24" LIGHT GRAY IP07 FLOOR FIELD TILE - RESTROOM
PT2 PORCELAIN MOSAIC TILE DALTILE KEYSTONE 2" X 1" MOSAIC BLEND MOONLIGHT DK14 FLOOR SHOWERS
RB1 RESILIENT BASE JOHNSONITE 4" TRADITIONAL - COVED STORM CLOUD 71 WALL FIELD BASE
SC1 SEALED CONCRETE SEE SPECIFICATIONS N/A N/A EXPOSED FLOORS
SS1 SOLID SURFACE CORIAN TERRA COLLECTION PLATINUM COUNTERTOPS - RESTROOMS W/ 4" COVED BACK/SIDE SPLASH
SS2 SOLID SURFACE CORIAN PRIVATE COLLECTION ARROWROOT COUNTERTOPS - BREAKROOM W/ 4" COVED BACK/SIDE SPLASH
SS3 SOLID SURFACE CORIAN N/A DOVE WINDOW STOOLS
SS4 SOLID SURFACE CORIAN N/A GLACIER WHITE INTEGRAL SINK BOWLS
TP1 TOILET PARTITIONS ASI ACCURATE PARTITIONS SOLID PLASTIC / HAMMERED METALLIC SILVER 9511 RESTROOMS
WM1 WALK OFF MAT CONSTRUCTION SPECIALTIES PEDISYSTEMS GUNMETAL 7324 VESTIBULE
WT1 WINDOW TREATMENT - MINI BLINDS HUNTER DOUGLAS 1" ALUMINUM HORIZONTAL PLATINUM GRAY 981 EXTERIOR WINDOWS - OFFICE / BREAK AREA
LEGEND - FINISH
ACP ACOUSTICAL CEILING PANEL
CG CORNER GUARD
CT CERAMIC TILE
CTB CERAMIC TILE WALL BASE
EF EPOXY FLOORING
GT GROUT
HF HANGAR FLOOR SYSTEM - 5 COAT
P PAINT
PL PLASTIC LAMINATE
PT PORCELAIN TILE
RB RESILIENT BASE
SC SEALED CONCRETE
SS SOLID SURFACE
TP TOILET PARTITION
WM WALK OFF MAT
WT WINDOW TREATMENT
SCHEDULE - INTERIOR FINISH - ROOMS
ROOM BASE
FINISH
FLOORS WALLS CEILINGS
COMMENTS
ACCESSORIES &
WINDOW TREATMENTSNUMBER NAME FINISH FINISH FINISH
100 TER N/A SC1 P1 EXPOSED
101 OPEN OFFICE RB1 EF1 P1 / P2 ACP1 WT1
102 OFFICE RB1 EF1 P1 ACP1 WT1
103 OFFICE RB1 EF1 P1 ACP1 WT1
104 BREAKROOM RB1 EF1 P1 / P2 ACP1 WT1
104A EQUIP CLOSET RB1 EF1 P1 ACP1
105 HANGAR N/A HF1 P1 EXPOSED SAFETY STRIPING
106 MECHANICAL ROOM N/A SC1 P1 EXPOSED
107 ELEC RB1 SC1 P1 EXPOSED
108 FUEL CELL TOOL ROOM RB1 EF1 P1 EXPOSED
109 TOOL CRIB RB1 EF1 P1 EXPOSED
110 TR N/A SC1 P1 EXPOSED
111 ELECTRICAL ROOM N/A SC1 P1 EXPOSED
112 MECH N/A SC1 P1 EXPOSED
113 FIRE PUMP AND FOAM TANK ROOM N/A SC1 P1 EXPOSED
C001 HALLWAY RB1 HF1 P1 ACP1
C002 CORRIDOR RB1 HF1 P1 ACP1
G001 J.C. RB1 SC1 P6 EXPOSED
G002 RESTROOM CTB1 PT1 CT - SEE IN501 ACP2 SEE IN501 FOR WALL TILE PATTERN
G003 RESTROOM WOMEN'S CTB1 PT1 CT - SEE IN501 ACP2 SEE IN501 FOR WALL TILE PATTERN
G004 RESTROOM MEN'S CTB1 PT1 CT - SEE IN501 ACP2 SEE IN501 FOR WALL TILE PATTERN
G005 WOMENS LOCKER RM CTB1 PT1 / PT2 CT - SEE IN501 ACP2 / P4 P4 AT SHOWER CEILING; PT2 AT SHOWER FLOORS
G006 MENS LOCKER RM CTB1 PT1 / PT2 CT - SEE IN501 ACP2 / P4 P4 AT SHOWER CEILING; PT2 AT SHOWER FLOORS
L001 LOBBY RB1 EF1 P1 / P2 ACP1 CG1
V001 VESTIBULE RB1 WM1 P1 ACP1
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
F E
C
IN111
IN113
IN113
IN
IN112
IN
IN114
IN114
IN115IN115
IN114IN113
IN114
IN112IN111
IN113
0.2 0.4
A
A.6
B
0.9 1 2 3 4 5
5.2
6 7 8
8.8
9 10 11 12 13
C
D
D.1
D.6
F
G
H
J
K
L
M
N
M.1
E
BREAKROOM
OPEN OFFICE
LOBBY
L001
RESTROOM WOMEN'S
G003
RESTROOM MEN'S
G004
MENS LOCKER RM
G006
MECHANICAL ROOM
WOMENS LOCKER RM
G005
TER
VESTIBULE
V001
ELEC
FUEL CELL TOOL ROOM
TOOL CRIB
HANGAR
MECH
EQUIP CLOSET
104A
OFFICE
OFFICE
C5
C17
F.7
F.8
1. SEE IN001 FOR INTERIOR FINISH DETAILED NOTES,
LEGEND, AND SCHEDULES.
2. SEE IN500 SERIES FOR INTERIOR FINISH
ENLARGED PLAN & DETAILS.
3. SEE IG001 FOR SIGNAGE DETAILED NOTES,
LEGENDS & SCHEDULES.
4. SEE IG500 SERIES FOR SIGNAGE DETAILS.
5. HANGAR SAFETY STRIPING COLORS ARE TO BE IN
ACCORDANCE WITH BASE PROPERTY STANDARDS.
GENERAL NOTES - FINISH
PNN
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
A B
C D
E
KEY PLAN
1 2 3 4 5
/1
/2
:4
:3
P M
IN110
C O
M P
R E
H E
N S
IV
E
F
IN
IS
H P
L A
N
A L M
R D
T
L J B
R T
A
D
E C
D
E C
SCALE: 1" = 20'-0"
COMPREHENSIVE - FINISH PLAN
SCALE:
0' - 10" 1' - 8" 3' - 4"
1' - 0" = 20' - 0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
F E C
RESTROOM WOMEN'S
G003
TER
HANGAR
IN113
IN
IN114
IN112
IN113
3' - 4" 6' - 6"
6' - 6"
C L
27' - 3 1/4"
MISSION SIGNAGE
PROVIDED BY THE
USER.
WOMENS LOCKER RM
G005
LOBBY
L001
AIRCRAFT CLEARANCE
BOUNDARY LINE - 6" WIDE
STRIP, YELLOW
ALIGN STRIPING ON
THIS CORNER
HAZARD ZONE
STRIPING - YELLOW.
6" WIDE DIAGONAL
LINES 48" APART O.C.
IN
P2
P2
P
P2
MB1
TB1
MB2
BB1
TVs ARE SHOWN FOR REFERENCE
ONLY. SEE TELECOM DRAWINGS
FOR LOCATIONS AND INFORMATION.
TYPICAL ALL TV1 & TV2.
CG1 CG1 CG1
CG1
CG1
OFFICE
BREAKROOM
VESTIBULE
V001
J.C.
G001
OFFICE
RESTROOM
G002
HALLWAY
C001
IN111 IN501
0.2 0.4
A
A.6
B
0.9 1 2 3 4 5 6 7
C
D
D.1
D.6
TV1 TV1
TV1 TV1
E
CL
AIRCRAFT POSITION
CENTERLINE - 6" WIDE
STRIP, YELLOW
SAFETY EYEWASH
CLEARANCE BOUNDARY
LINE - 6" WIDE STRIP, GREEN
IN111 IN501
EQUIP CLOSET
104A
CL
CL
CL
OPEN OFFICE
TV2
11' - 8"
IN111 IN501
TYPICAL
TYPICAL
TYPICAL
GROUNDING RECEPTACLE
SAFETY STRIPING, TYPICAL
ALL - SEE DETAIL
1. SEE IN001 FOR INTERIOR FINISH DETAILED NOTES,
LEGEND, AND SCHEDULES.
2. SEE IN500 SERIES FOR INTERIOR FINISH
ENLARGED PLAN & DETAILS.
3. SEE IG001 FOR SIGNAGE DETAILED NOTES,
LEGENDS & SCHEDULES.
4. SEE IG500 SERIES FOR SIGNAGE DETAILS.
5. HANGAR SAFETY STRIPING COLORS ARE TO BE IN
ACCORDANCE WITH BASE PROPERTY STANDARDS.
GENERAL NOTES - FINISH
1. SEE IG001 FOR SIGNAGE DETAILED NOTES,
LEGEND AND SCHEDULE.
2. SEE IG500 SERIES FOR SIGNAGE DETAILS.
GENERAL NOTES - SIGNAGE
PNN
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
A B
C D
E
KEY PLAN
1 2 3 4 5
/1
/2
:4
:4
P M
IN111
F
IN
IS
H S
IG
N A G E S T F L O O R P L A N A R E A A
A L M
R D
T
L J B
R T A D E C
D
E C
SCALE:
4' - 0" 8' - 0" 16' - 0"
0' - 0 1/8" = 1' - 0"
SCALE: 1/8" = 1'-0"IN111
1 FINISH & SIGNAGE - 1ST FLOOR PLAN - AREA A
IN110
LEGEND - FINISH
ACP ACOUSTICAL CEILING PANEL
CG CORNER GUARD
CT CERAMIC TILE
CTB CERAMIC TILE WALL BASE
EF EPOXY FLOORING
GT GROUT
HF HANGAR FLOOR SYSTEM - 5 COAT
P PAINT
PL PLASTIC LAMINATE
PT PORCELAIN TILE
RB RESILIENT BASE
SC SEALED CONCRETE
SS SOLID SURFACE
TP TOILET PARTITION
WM WALK OFF MAT
WT WINDOW TREATMENT
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
IN
IN114IN114
IN111
IN113
AIRCRAFT CLEARANCE
BOUNDARY LINE - 6" WIDE
STRIP, YELLOW
HAZARD ZONE
STRIPING - YELLOW.
6" WIDE DIAGONAL
LINES 48" APART O.C.
F R O M
Y E
LL
O W
P A
IN
T E D
H A Z A R D
L
IN
E
F R O M
Y E
LL
O W
P A
IN
T E D
H A Z A R D
L
IN
E
45A
B
7 8 9 10 11 12 13
C
D
D.1
D.6
DIMENSIONS OF HAZARD STRIPING ZONE TO
ALIGN WITH THE VERTICAL PLANE OF THE
VERTICAL LIFT FABRIC DOORS
E
AIRCRAFT POSITION
CENTERLINE - 6" WIDE
STRIP, YELLOW
SAFETY EYEWASH
CLEARANCE BOUNDARY
LINE - 6" WIDE STRIP, GREEN
11' - 0"
GROUNDING RECEPTACLE
SAFETY STRIPING, TYPICAL
ALL - SEE DETAIL
1. SEE IN001 FOR INTERIOR FINISH DETAILED NOTES,
LEGEND, AND SCHEDULES.
2. SEE IN500 SERIES FOR INTERIOR FINISH
ENLARGED PLAN & DETAILS.
3. SEE IG001 FOR SIGNAGE DETAILED NOTES,
LEGENDS & SCHEDULES.
4. SEE IG500 SERIES FOR SIGNAGE DETAILS.
5. HANGAR SAFETY STRIPING COLORS ARE TO BE IN
ACCORDANCE WITH BASE PROPERTY STANDARDS.
GENERAL NOTES - FINISH
1. SEE IG001 FOR SIGNAGE DETAILED NOTES,
LEGEND AND SCHEDULE.
2. SEE IG500 SERIES FOR SIGNAGE DETAILS.
GENERAL NOTES - SIGNAGE
PNN
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
A B
C D
E
KEY PLAN
1 2 3 4 5
/1
/2
:4
:5
P M
IN112
F
IN
IS
H
S
IG
N
A G
E
S
T F
L O
O R
P L
A N
A
R E
A B
A L M
R D
T
L J B
R T
A
D
E C
D
E C
SCALE: 1/8" = 1'-0"IN112
1 FINISH & SIGNAGE - 1ST FLOOR PLAN - AREA B
IN110
LEGEND - FINISH
ACP ACOUSTICAL CEILING PANEL
CG CORNER GUARD
CT CERAMIC TILE
CTB CERAMIC TILE WALL BASE
EF EPOXY FLOORING
GT GROUT
HF HANGAR FLOOR SYSTEM - 5 COAT
P PAINT
PL PLASTIC LAMINATE
PT PORCELAIN TILE
RB RESILIENT BASE
SC SEALED CONCRETE
SS SOLID SURFACE
TP TOILET PARTITION
WM WALK OFF MAT
WT WINDOW TREATMENT
SCALE:
4' - 0" 8' - 0" 16' - 0"
0' - 0 1/8" = 1' - 0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
RESTROOM MEN'S
G004
TOOL CRIB
FUEL CELL TOOL ROOM
ELEC
MECHANICAL ROOM
CORRIDOR
C002
HANGAR
IN111
IN115
IN114
IN114
IN112IN111
MENS LOCKER RM
G006
AIRCRAFT CLEARANCE
BOUNDARY LINE - 6"
WIDE STRIP, YELLOW
IN113 IN501
0.2 0.4 0.9 1 2 3 4 5
5.2
6 7
F
G
H
J
K
SAFETY EYEWASH
CLEARANCE BOUNDARY
LINE - 6" WIDE STRIP, GREEN
SAFETY EYEWASH
CLEARANCE BOUNDARY
LINE - 6" WIDE STRIP, GREEN
SAFETY EYEWASH
CLEARANCE BOUNDARY
LINE - 6" WIDE STRIP, GREEN
9' - 10"
61' - 6 7/8"
18' - 7 3/4"
.1
.1
21' - 11 1/4"
BREAK SAFETY STRIPING
AT GROUNDING
RECEPTACLE STRIPING
GROUNDING RECEPTACLE
SAFETY STRIPING, TYPICAL
ALL - SEE DETAIL
C5
C17
F.7
F.8
1. SEE IN001 FOR INTERIOR FINISH DETAILED NOTES,
LEGEND, AND SCHEDULES.
2. SEE IN500 SERIES FOR INTERIOR FINISH
ENLARGED PLAN & DETAILS.
3. SEE IG001 FOR SIGNAGE DETAILED NOTES,
LEGENDS & SCHEDULES.
4. SEE IG500 SERIES FOR SIGNAGE DETAILS.
5. HANGAR SAFETY STRIPING COLORS ARE TO BE IN
ACCORDANCE WITH BASE PROPERTY STANDARDS.
GENERAL NOTES - FINISH
1. SEE IG001 FOR SIGNAGE DETAILED NOTES,
LEGEND AND SCHEDULE.
2. SEE IG500 SERIES FOR SIGNAGE DETAILS.
GENERAL NOTES - SIGNAGE
PNN
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
A B
C D
E
KEY PLAN
1 2 3 4 5
/1
/2
:4
:0
P M
IN113
F
IN
IS
H
S
IG
N
A G
E
S
T F
L O
O R
P L
A N
A
R E
A C
A L M
R D
T
L J B
R T
A
D
E C
D
E C
SCALE: 1/8" = 1'-0"IN113
1 FINISH & SIGNAGE - 1ST FLOOR PLAN - AREA C
IN110
LEGEND - FINISH
ACP ACOUSTICAL CEILING PANEL
CG CORNER GUARD
CT CERAMIC TILE
CTB CERAMIC TILE WALL BASE
EF EPOXY FLOORING
GT GROUT
HF HANGAR FLOOR SYSTEM - 5 COAT
P PAINT
PL PLASTIC LAMINATE
PT PORCELAIN TILE
RB RESILIENT BASE
SC SEALED CONCRETE
SS SOLID SURFACE
TP TOILET PARTITION
WM WALK OFF MAT
WT WINDOW TREATMENT
SCALE:
4' - 0" 8' - 0" 16' - 0"
0' - 0 1/8" = 1' - 0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
ELECTRICAL ROOM
TR
IN112
IN115
HANGAR
IN112IN111
IN113
AIRCRAFT CLEARANCE
BOUNDARY LINE - 6"
WIDE STRIP, YELLOW
7 8
8.8
9 10 11 12 13
F
G
H
J
K
101104
AIRCRAFT POSITION
CENTERLINE - 6" WIDE
STRIP, YELLOW
SAFETY EYEWASH
CLEARANCE BOUNDARY
LINE - 6" WIDE STRIP, GREEN
SAFETY EYEWASH
CLEARANCE BOUNDARY
LINE - 6" WIDE STRIP, GREEN
SAFETY EYEWASH
CLEARANCE BOUNDARY
LINE - 6" WIDE STRIP, GREEN
40' - 5"
17' - 11 3/4"
.1
.1
60' - 10 7/8"
11' - 0"
BREAK SAFETY STRIPING
AT GROUNDING
RECEPTACLE STRIPING
GROUNDING RECEPTACLE
SAFETY STRIPING, TYPICAL
ALL - SEE DETAIL
SAFETY STRIPE SHOWING EXTENTS OF
REINFORCED SLAB FOR JACKING POINTS. -
6" WIDE STRIP, YELLOW.
SEE S-SERIES FOR SPECIFIC INFORMATION
REGARDING REINFORCED SLAB LOCATIONS
1. SEE IN001 FOR INTERIOR FINISH DETAILED NOTES,
LEGEND, AND SCHEDULES.
2. SEE IN500 SERIES FOR INTERIOR FINISH
ENLARGED PLAN & DETAILS.
3. SEE IG001 FOR SIGNAGE DETAILED NOTES,
LEGENDS & SCHEDULES.
4. SEE IG500 SERIES FOR SIGNAGE DETAILS.
5. HANGAR SAFETY STRIPING COLORS ARE TO BE IN
ACCORDANCE WITH BASE PROPERTY STANDARDS.
GENERAL NOTES - FINISH
1. SEE IG001 FOR SIGNAGE DETAILED NOTES,
LEGEND AND SCHEDULE.
2. SEE IG500 SERIES FOR SIGNAGE DETAILS.
GENERAL NOTES - SIGNAGE
PNN
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
A B
C D
E
KEY PLAN
1 2 3 4 5
/1
/2
:4
:0
P M
IN114
F
IN
IS
H
S
IG
N
A G
E
S
T F
L O
O R
P L
A N
A
R E
A D
A L M
R D
T
L J B
R T
A
D
E C
D
E C
SCALE: 1/8" = 1'-0"IN114
1 FINISH & SIGNAGE - 1ST FLOOR PLAN - AREA D
IN110
LEGEND - FINISH
ACP ACOUSTICAL CEILING PANEL
CG CORNER GUARD
CT CERAMIC TILE
CTB CERAMIC TILE WALL BASE
EF EPOXY FLOORING
GT GROUT
HF HANGAR FLOOR SYSTEM - 5 COAT
P PAINT
PL PLASTIC LAMINATE
PT PORCELAIN TILE
RB RESILIENT BASE
SC SEALED CONCRETE
SS SOLID SURFACE
TP TOILET PARTITION
WM WALK OFF MAT
WT WINDOW TREATMENT
SCALE:
4' - 0" 8' - 0" 16' - 0"
0' - 0 1/8" = 1' - 0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
MECH
ELECTRICAL ROOM
FIRE PUMP AND FOAM
TANK ROOM
TR
HANGAR
IN113 IN114
102103
AIRCRAFT CLEARANCE BOUNDARY
LINE - 6" WIDE STRIP, YELLOW
5 5.2 6 7 8 8.8 9 10 11 12 13
K
L
M
N
M.1
C5 AIRCRAFT POSITION
NOSE GEAR STOP - 6" WIDE
STRIP, YELLOW
21' - 11 1/4"
40' - 5"
/8
18' - 7 3/4" 17' - 11 3/4"
/4
GROUNDING RECEPTACLE
SAFETY STRIPING, TYPICAL
ALL - SEE DETAIL
C17 AIRCRAFT POSITION
NOSE GEAR STOP - 6" WIDE
STRIP, YELLOW
C5
C5
1. SEE IN001 FOR INTERIOR FINISH DETAILED NOTES,
LEGEND, AND SCHEDULES.
2. SEE IN500 SERIES FOR INTERIOR FINISH
ENLARGED PLAN & DETAILS.
3. SEE IG001 FOR SIGNAGE DETAILED NOTES,
LEGENDS & SCHEDULES.
4. SEE IG500 SERIES FOR SIGNAGE DETAILS.
5. HANGAR SAFETY STRIPING COLORS ARE TO BE IN
ACCORDANCE WITH BASE PROPERTY STANDARDS.
GENERAL NOTES - FINISH
1. SEE IG001 FOR SIGNAGE DETAILED NOTES,
LEGEND AND SCHEDULE.
2. SEE IG500 SERIES FOR SIGNAGE DETAILS.
GENERAL NOTES - SIGNAGE
PNN
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
A B
C D
E
KEY PLAN
1 2 3 4 5
/1
/2
:4
:1
P M
IN115
F
IN
IS
H
S
IG
N
A G
E
S
T F
L O
O R
P L
A N
A
R E
A E
A L M
R D
T
L J B
R T
A
D
E C
D
E C
SCALE: 1/8" = 1'-0"IN115
1 FINISH & SIGNAGE - 1ST FLOOR PLAN - AREA E
IN110
LEGEND - FINISH
ACP ACOUSTICAL CEILING PANEL
CG CORNER GUARD
CT CERAMIC TILE
CTB CERAMIC TILE WALL BASE
EF EPOXY FLOORING
GT GROUT
HF HANGAR FLOOR SYSTEM - 5 COAT
P PAINT
PL PLASTIC LAMINATE
PT PORCELAIN TILE
RB RESILIENT BASE
SC SEALED CONCRETE
SS SOLID SURFACE
TP TOILET PARTITION
WM WALK OFF MAT
WT WINDOW TREATMENT
SCALE:
4' - 0" 8' - 0" 16' - 0"
0' - 0 1/8" = 1' - 0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
CT1 FIELD WALL TILE
CT1 FIELD WALL TILE
CT1 FIELD WALL TILE
CT1 FIELD WALL TILE
CT2 ACCENT WALL TILE
CT3 ACCENT WALL TILE
CT3 ACCENT WALL TILE
CT4 ACCENT WALL TILE
CT2 ACCENT WALL TILE
FINISHED CEILING
FINISHED FLOOR
CTB1 TILE WALL BASE
3' 1"
V A R
IE
S
5'
C L
NOTE: SEE OUTSIDE/INSIDE CORNER TRANSITION DETAILS
1/4" RADIUS
ACROVYN 4000 COVER
REGRIND RETAINER
HARDWARE PER
MANUFACTURERS
RECOMMENDATION
WALL SUBSTRATE
3"
3"
NOTE: CORNER GUARD TO START AT
TOP OF WALL BASE AND RUN TO 72"
AFF. ALL MATCHING FINISH CAPS &
TRIM ARE TO BE PROVIDED
OUTSIDE CORNER TILE CONDITION
WALL SUBSTRATE
WALL TILE
SCHLUTER
JOLLY EB
BRUSHED
STAINLESS WALL TILE
PORCELAIN FLOOR TILE
PORCELAIN TILE FLOOR TO CERAMIC TILE WALL TRANSITION
W A
LL
FLOOR
CERAMIC COVED WALL BASE
FLEXIBLE SEALANT STAINED
TO MATCH GROUT
CERAMIC WALL TILE
SUBSTRATE
SEALED CONCRETE
METAL REDUCER
POURED EPOXY
FLOORING / HANGAR
FLOORING SYSTEM
SUBSTRATE
PORCELAIN TILE
METAL REDUCER
HANGAR
FLOORING
SYSTEM
SUBSTRATE
METAL DIVIDER
POURED EPOXY
FLOORING
POURED EPOXY
FLOORING / HANGAR
FLOORING SYSTEM
PORCELAIN
TILE - PT1
SUBSTRATE
METAL DIVIDER
MOSAIC TILE -
PT2
ALIGN TILES
WALL BASE AS
SCHEDULED
FINISHED FLOOR
CG1 CORNER
GUARD
6'
4"
WALL TILE BASE AS
SCHEDULED
FINISHED FLOOR
WALL TILE AS SCHEDULED
SCHLUTER JOLLY CORNER
TRIM
INSIDE CORNER TILE CONDITION
WALL
SUBSTRATE
WALL TILE
WALL TILE
SILCONE JOINT TO
MATCH GROUT COLOR
WALL
SUBSTRATE
SAW CUT CONTROL
JOINT
CONTROLLED CRACK
OR CONTROL JOINT
CONCRETE
BOND COAT
TILE
CJ1 - CTC JOINT DXJ 38
CJ2 - CTC JOINT DXJ 14
NOTE: CJ1 & CJ2 ARE TO BE LOCATED DIRECTLY
ABOVE CONTROL JOINT LOCATIONS WHERE FLOOR
TILE IS SCHEDULED. CJ1 IS TO BE USED WITH PT1
AND CJ2 IS TO BE USED WITH PT2. COLOR TO MATCH
GROUT.
RESTROOM WOMEN'S
G003
WOMENS LOCKER RM
G005
PT2 CONTROL
JOINT - CJ2
CONTROL JOINT - CJ1
CONTROL JOINT -
CJ1
PT1 TO BE LAID IN A 1/3
OFFSET RUNNING BRICK
LAY PATTERN. START WITH
FULL TILES LAID AT
CONTROL JOINT LOCATION.
COORDINATE CONTROL
LOCATION WITH S-SERIES
DRAWINGS.
PT2 PT2 PT2
EQ EQ
PT1 START
POINT
RESTROOM MEN'S
G004
MENS LOCKER RM
G006
CONTROL JOINT - CJ1
6'
CL
PT1 TO BE LAID IN A 1/3 OFFSET
RUNNING BRICK LAY PATTERN.
START WITH FULL TILES LAID AT
CONTROL JOINT LOCATION.
COORDINATE CONTROL
LOCATION WITH S-SERIES
DRAWINGS.
NOTE: CONTROL JOINT
LOCATIONS ARE FOR
REFERENCE ONLY. SEE S-SERIES
STRUCTURAL DRAWINGS FOR
SPECIFIC INFORMATION
REGARDING CONTROL JOINT
LOCATIONS.
NOTE:
• DIMENSIONS TYPICAL OF ALL EYEWASH
STATION LOCATIONS WITHIN HANGAR BAY
• PROVIDE 2'-0" CLEARANCE AROUND SAFETY
EYEWASH/SHOWER EQUIPMENT, THEN
PROCEED 6" OUT FOR STRIPING BOX
2'
2'
5' - 0" 6"
E Q
E Q
C L
2' - 0"
SAFETY EYEWASH STATION
CLEARANCE BOUNDARY LINE
- 6" WIDE, GREEN
2"
1' - 6"
2"
GROUND RECEPTACLE
SET IN FLOOR
2 3/4"
YELLOW PAINT
RED PAINT
GROUND
PAINT THE WORD "GROUND" IN 1"
BLACK LETTERS AND THE DATE
TESTED IN 1/2" BLACK LETTERS
(COORDINATE WITH ELECTRICAL
CONTRACTOR)
TESTING DATE
NOTES:
1. SEE UFC 3-375-01, FIGURE 2-3 GROUNDING RECEPTACLE FOR
FURTHER INFORMATION.
2. COORDINATE FINAL LOCATIONS AND QUANITITIES WITH
ELECTRICAL DRAWINGS AND ELECTRICAL CONTRACTOR.
3. PAINT COLORS ASSOCIATED WITH STATIC GROUNDING
SERVICES VARY WITH APPLICATION AND SERVICE;
COORDINATE WITH LOCAL JURISDICTION.
4. THE PAINT IS APPLIED DIRECTLY TO THE HANGAR FLOOR OR
APRON PAVEMENT AND IS NOT APPLIED TO THE RECEPTACLE.
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
1 2 3 4 5
/1
/2
:4
:2
P M
IN501
E N L A R G E D I N T E R
IO
R F
IN
IS
H P L A N S D E T A
IL
S
A L M
R D
T
L J B
R T A D E C
D
E C
SCALE:
1' - 0" 2' - 0" 4' - 0"
0' - 0 1/2" = 1' - 0"
SCALE: 1/2" = 1'-0"IN501
TYPICAL WALL TILE PATTERN - RESTROOMS /
SHOWERS
SCALE: 6" = 1'-0"IN501
7 FINISH DETAIL - TYPICAL CORNER GUARD (CG1)
SCALE: NTSIN501
FINISH DETAIL - OUTSIDE TILE CORNER
TRANSITION
SCALE: NTSIN501
FINISH DETAIL - INTERIOR WALL
TO FLOOR TRANSITION
SCALE: NTSIN501
8 FINISH DETAIL - INTERIOR FLOORING TRANSITIONS
SCALE: 1/2" = 1'-0"IN501
FINISH DETAIL - CORNER
GUARD / WALL BASE
SCALE: 1 1/2" = 1'-0"IN501
FINISH DETAIL - OUTSIDE TILE
CORNER AT WALL BASE
SCALE: NTSIN501
FINISH DETAIL - INSIDE TILE
CORNER TRANSITION
SCALE:
0' - 1 1/2" 0' - 3" 0' - 6"
0' - 6" = 1' - 0"
SCALE:
1' - 0" 2' - 0" 4' - 0"
0' - 0 3/4" = 1' - 0"
SCALE:
0' - 6" 1' - 0" 2' - 0"
0' - 1 1/2" = 1' - 0"
SCALE: 3" = 1'-0"IN501
11 FINISH DETAIL - CONTROL JOINT
SCALE:
0' - 3" 0' - 6" 1' - 0"
0' - 3" = 1' - 0"
SCALE: 1/4" = 1'-0"IN111 IN501
ENLARGED PLAN - FLOOR PATTERN - WOMENS
RESTROOM & LOCKER ROOM
SCALE: 1/4" = 1'-0"IN113 IN501
ENLARGED PLAN - FLOOR PATTERN - MENS
RESTROOM & LOCKER ROOM
SCALE:
2' - 0" 4' - 0" 8' - 0"
0' - 0 1/4" = 1' - 0"
SCALE: 1/2" = 1'-0"IN111 IN501
TYPICAL DETAIL - EYEWASH
SAFETY STRIPING
SCALE: 1" = 1'-0"IN111 IN501
TYPICAL DETAIL - GROUNDING RECEPTACLE
SAFETY STRIPING
SCALE:
0' - 6" 1' - 0" 2' - 0"
0' - 1" = 1' - 0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
IN501 IN501 IN501 IN501 IN501
IN501 IN501
IN501
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
1 2 3 4 5
/1
/2
:4
:5
P M
IG001
S
IG
N A
G E
D E
T A
IL
E
D N
O T
E S
, L E
G E
N D
S
S C
H E
D U
L E
S
A L M
R D
T
L J B
R T
A
D
E C
D
E C
SCHEDULE - SIGNAGE
SIGN TAG
ROOM
TYPE SIGN TYPE SIGN MESSAGE (AS APPLICABLE) COMMENTSNUMBER NAME
60 C002 CORRIDOR P EXIT MOUNTED ON INTERIOR OF DOOR
61 C002 CORRIDOR D.2 ROOM ID - EXTERIOR "105"
62 C002 CORRIDOR N NO SMOKING EXTERIOR
63 106 MECHANICAL ROOM R.2 WARNING SIGN - RESTRICTED AREA MOUNTED ON EXTERIOR OF DOOR
64 106 MECHANICAL ROOM D.2 ROOM ID - EXTERIOR "106"
65 106 MECHANICAL ROOM N NO SMOKING EXTERIOR
66 107 ELEC R.2 WARNING SIGN - RESTRICTED AREA MOUNTED ON EXTERIOR OF DOOR
67 107 ELEC D.2 ROOM ID - EXTERIOR "107"
68 108 FUEL CELL TOOL ROOM R.2 WARNING SIGN - RESTRICTED AREA MOUNTED ON EXTERIOR OF DOOR
69 108 FUEL CELL TOOL ROOM P EXIT MOUNTED ON INTERIOR OF DOOR
70 108 FUEL CELL TOOL ROOM D.2 ROOM ID - EXTERIOR "108"
71 108 FUEL CELL TOOL ROOM N NO SMOKING EXTERIOR
72 108 FUEL CELL TOOL ROOM D.1 ROOM ID - INTERIOR "108 / FUEL CELL TOOL ROOM"
73 108 FUEL CELL TOOL ROOM G.2 EYEWASH
74 109 TOOL CRIB D.1 ROOM ID - INTERIOR "109 / TOOL CRIB"
75 108 FUEL CELL TOOL ROOM D.1 ROOM ID - INTERIOR "108 / FUEL CELL TOOL ROOM"
76 109 TOOL CRIB D.1 ROOM ID - INTERIOR "109 / TOOL CRIB"
77 105 HANGAR G.2 EYEWASH
78 109 TOOL CRIB G.2 EYEWASH
79 109 TOOL CRIB R.2 WARNING SIGN - RESTRICTED AREA MOUNTED ON EXTERIOR OF DOOR
80 109 TOOL CRIB P EXIT MOUNTED ON INTERIOR OF DOOR
81 109 TOOL CRIB D.2 ROOM ID - EXTERIOR "109"
82 109 TOOL CRIB N NO SMOKING EXTERIOR
83 105 HANGAR S FIRE PROTECTION FOAM SYSTEM
84 105 HANGAR R.2 WARNING SIGN - RESTRICTED AREA MOUNTED ON EXTERIOR OF DOOR
85 105 HANGAR P EXIT MOUNTED ON INTERIOR OF DOOR
86 105 HANGAR D.2 ROOM ID - EXTERIOR "105"
87 105 HANGAR N NO SMOKING EXTERIOR
88 105 HANGAR G.2 EYEWASH
89 105 HANGAR G.2 EYEWASH
90 105 HANGAR R.2 WARNING SIGN - RESTRICTED AREA MOUNTED ON EXTERIOR OF DOOR
91 105 HANGAR P EXIT MOUNTED ON INTERIOR OF DOOR
92 105 HANGAR D.2 ROOM ID - EXTERIOR "105"
93 105 HANGAR N NO SMOKING EXTERIOR
94 105 HANGAR S FIRE PROTECTION FOAM SYSTEM
95 105 HANGAR G.2 EYEWASH
96 105 HANGAR N NO SMOKING EXTERIOR
97 105 HANGAR D.2 ROOM ID - EXTERIOR "105"
98 105 HANGAR P EXIT MOUNTED ON INTERIOR OF DOOR
99 105 HANGAR R.2 WARNING SIGN - RESTRICTED AREA MOUNTED ON EXTERIOR OF DOOR
100 105 HANGAR S FIRE PROTECTION FOAM SYSTEM
101 111 ELECTRICAL ROOM R.2 WARNING SIGN - RESTRICTED AREA MOUNTED ON EXTERIOR OF DOOR
102 111 ELECTRICAL ROOM D.2 ROOM ID - EXTERIOR "111"
103 110 TR D.1 ROOM ID - INTERIOR "110 / TELECOMMUNICATIONS ROOM"
104 105 HANGAR G.2 EYEWASH
105 113 FIRE PUMP AND FOAM
TANK ROOM
N NO SMOKING EXTERIOR
106 113 FIRE PUMP AND FOAM
TANK ROOM
D.2 ROOM ID - EXTERIOR "113"
107 113 FIRE PUMP AND FOAM
TANK ROOM
R.2 WARNING SIGN - RESTRICTED AREA MOUNTED ON EXTERIOR OF DOOR
108 112 MECH D.2 ROOM ID - EXTERIOR "112"
109 112 MECH R.2 WARNING SIGN - RESTRICTED AREA "112" MOUNTED ON EXTERIOR OF DOOR
110 112 MECH P EXIT MOUNTED ON INTERIOR OF DOOR
111 105 HANGAR N NO SMOKING EXTERIOR
112 105 HANGAR R.2 WARNING SIGN - RESTRICTED AREA MOUNTED ON EXTERIOR OF DOOR
113 105 HANGAR P EXIT MOUNTED ON INTERIOR OF DOOR
114 105 HANGAR D.2 ROOM ID - EXTERIOR "105"
115 105 HANGAR S FIRE PROTECTION FOAM SYSTEM
116 105 HANGAR P EXIT MOUNTED ON INTERIOR OF DOOR
117 105 HANGAR N NO SMOKING EXTERIOR
118 105 HANGAR D.2 ROOM ID - EXTERIOR "105"
119 105 HANGAR R.2 WARNING SIGN - RESTRICTED AREA MOUNTED ON EXTERIOR OF DOOR
120 105 HANGAR S FIRE PROTECTION FOAM SYSTEM
121 105 HANGAR L.1 MANDATORY "CATWALK ACCESS AUTHORIZED PERSONNEL ONLY. MAXIMUM
LOAD CAPACITY 40 PSF"
122 105 HANGAR S FIRE PROTECTION FOAM SYSTEM
123 105 HANGAR N NO SMOKING
124 105 HANGAR D.2 ROOM ID - EXTERIOR "105"
125 105 HANGAR P EXIT MOUNTED ON INTERIOR OF DOOR
126 105 HANGAR R.2 WARNING SIGN - RESTRICTED AREA MOUNTED ON EXTERIOR OF DOOR
127 105 HANGAR T FIRE PROTECTION FOAM RELEASE
128 105 HANGAR T FIRE PROTECTION FOAM RELEASE
129 105 HANGAR T FIRE PROTECTION FOAM RELEASE
130 105 HANGAR T FIRE PROTECTION FOAM RELEASE
131 105 HANGAR T FIRE PROTECTION FOAM RELEASE
132 105 HANGAR T FIRE PROTECTION FOAM RELEASE
133 105 HANGAR T FIRE PROTECTION FOAM RELEASE
134 105 HANGAR T FIRE PROTECTION FOAM RELEASE
135 105 HANGAR T FIRE PROTECTION FOAM RELEASE
136 105 HANGAR T FIRE PROTECTION FOAM RELEASE
SCHEDULE - SIGNAGE
SIGN TAG
ROOM
TYPE SIGN TYPE SIGN MESSAGE (AS APPLICABLE) COMMENTSNUMBER NAME
1 100 TER D.2 ROOM ID - EXTERIOR "100"
2 100 TER R.2 WARNING SIGN - RESTRICTED AREA MOUNTED ON EXTERIOR OF DOOR
3 V001 VESTIBULE A BUILDING ENTRANCE EXTERIOR
4 V001 VESTIBULE B BUILDING NUMBER EXTERIOR; MOUNTED ABOVE ENTRANCE DOORS
5 V001 VESTIBULE N NO SMOKING EXTERIOR
6 V001 VESTIBULE H BUILDING DIRECTORY
7 V001 VESTIBULE P EXIT MOUNTED ON INTERIOR OF DOOR
8 G001 J.C. D.1 ROOM ID - INTERIOR "G001 / JANITORS CLOSET"
9 L001 LOBBY J DRINKING FOUNTAIN
10 103 OFFICE D.1 ROOM ID - INTERIOR "103 / PRINTABLE INSERT (ROOM NAME, OCCUPANTS TITLE &
OCCUPANTS NAME; DETERMINED BY OWNER)"
11 102 OFFICE D.1 ROOM ID - INTERIOR "102 / PRINTABLE INSERT (ROOM NAME, OCCUPANTS TITLE &
OCCUPANTS NAME; DETERMINED BY OWNER)"
12 104A EQUIP CLOSET D.1 ROOM ID - INTERIOR "104A / EQUIPMENT CLOSET" MOUNTED ON BREAKROOM SIDE OF RIGHT DOOR
13 104 BREAKROOM P EXIT MOUNTED ON INTERIOR OF DOOR
14 104 BREAKROOM D.2 ROOM ID - EXTERIOR "104"
15 104 BREAKROOM N NO SMOKING EXTERIOR
16 104 BREAKROOM R.2 WARNING SIGN - RESTRICTED AREA MOUNTED ON EXTERIOR OF DOOR
17 104 BREAKROOM L.1 MANDATORY "MAXIMUM OCCUPANCY NOT TO EXCEED 79 PERSONS"
18 104 BREAKROOM L.1 MANDATORY CLASS K FIRE EXTINGUISHER; COORDINATE
REQUIRED SIGN VERBIAGE WITH LOCAL AHJ
19 104 BREAKROOM D.1 ROOM ID - INTERIOR "104 / BREAKROOM"
20 L001 LOBBY M.1 DIRECTIONAL
21 C001 HALLWAY P EXIT MOUNTED ON INTERIOR OF DOOR
22 G002 RESTROOM K.3 UNISEX TOILET MOUNT ON DOOR
23 G005 WOMENS LOCKER RM G.1 SHOWERS
24 G005 WOMENS LOCKER RM F.2 WOMENS LOCKER ROOM
25 G003 RESTROOM WOMEN'S K.2 WOMENS TOILET
26 105 HANGAR D.1 ROOM ID - INTERIOR "105 / HANGAR"
27 105 HANGAR P EXIT MOUNTED ON INTERIOR OF DOOR
28 105 HANGAR R.2 WARNING SIGN - RESTRICTED AREA MOUNTED ON EXTERIOR OF DOOR
29 105 HANGAR S FIRE PROTECTION FOAM SYSTEM
30 105 HANGAR L.2 MANDATORY LARGE "JACKING POINTS CAPACITY - 60 TON MAXIMUM "
31 105 HANGAR L.2 MANDATORY LARGE VENTILATION SYSTEM OPERATION INSTRUCTIONS INSTRUCTIONS TO BE PROVIDED BY VENTILATION
SYSTEM MANUFACTURER
32 105 HANGAR L.2 MANDATORY LARGE FIRE SUPRESSION SYSTEM OPERATION INSTRUCTIONS INSTRUCTIONS TO BE PROVIDED BE FIRE
PROTECTION SYSTEM MANUFACTURER
33 105 HANGAR G.2 EYEWASH
34 105 HANGAR R.4 WARNING SIGN - HANGAR DOOR
CONTROL
COORDINATE SIGN LOCATION WITH HANGAR DOOR
CONTROL PANEL.
35 105 HANGAR L.1 MANDATORY "EQUIPMENT ACCESS LADDER AUTHORIZED PERSONNEL ONLY" ADD MAXIMUM UNFORM LOADS AND
CONCENTRATED LOADS AS REQUIRED
36 105 HANGAR S FIRE PROTECTION FOAM SYSTEM
37 105 HANGAR P EXIT MOUNTED ON INTERIOR OF DOOR
38 105 HANGAR N NO SMOKING EXTERIOR
39 105 HANGAR D.2 ROOM ID - EXTERIOR "105"
40 105 HANGAR R.2 WARNING SIGN - RESTRICTED AREA MOUNTED ON EXTERIOR OF DOOR
41 105 HANGAR R.2 WARNING SIGN - RESTRICTED AREA LOCATED ON FLOOR
42 105 HANGAR R.1 FLOOR WARNING SIGN - HAZARDOUS
AREA
SIGN LOCATED ON FLOOR
43 105 HANGAR R.1 FLOOR WARNING SIGN - HAZARDOUS
AREA
SIGN LOCATED ON FLOOR; EXTERIOR SIDE OF
HANGAR DOOR
44 105 HANGAR R.2 WARNING SIGN - RESTRICTED AREA LOCATED ON FLOOR
45 105 HANGAR S FIRE PROTECTION FOAM SYSTEM
46 105 HANGAR R.2 WARNING SIGN - RESTRICTED AREA MOUNTED ON EXTERIOR OF DOOR
47 105 HANGAR P EXIT MOUNTED ON INTERIOR OF DOOR
48 105 HANGAR D.2 ROOM ID - EXTERIOR "105"
49 105 HANGAR N NO SMOKING EXTERIOR
50 105 HANGAR L.1 MANDATORY "EQUIPMENT ACCESS LADDER AUTHORIZED PERSONNEL ONLY" ADD MAXIMUM UNFORM LOADS AND
CONCENTRATED LOADS AS REQUIRED
51 105 HANGAR G.2 EYEWASH
52 G004 RESTROOM MEN'S K.1 MENS TOILET
53 G006 MENS LOCKER RM F.1 MENS LOCKER ROOM
54 G006 MENS LOCKER RM G.1 SHOWERS
55 105 HANGAR G.2 EYEWASH
56 105 HANGAR S FIRE PROTECTION FOAM SYSTEM
57 C002 CORRIDOR P EXIT MOUNTED ON INTERIOR OF DOOR
58 C002 CORRIDOR D.1 ROOM ID - INTERIOR "C002 / EXIT CORRIDOR"
59 C002 CORRIDOR R.2 WARNING SIGN - RESTRICTED AREA MOUNTED ON EXTERIOR OF DOOR
NOTE: SIGNAGE SCHEDULE IS PROVIDED AS REFERENCE FOR SIGN TYPES, QUANTITIES & LOCATIONS. FINAL ROOM NUMBERS AND SIGN VERBIAGE IS TO BE REVIEWED & APPROVED BY THE USERS/GOVERNMENT PRIOR TO ORDERING AND FABRICATION. SIGN MESSAGE WITH A "/" INDICATES PROGRESSION TO NEXT LINE OF SIGN.
NOTES - SIGNAGE
1 REFER TO ABAAS REQUIREMENTS & IG500 SERIES
REGARDING SIGN MOUNTING HEIGHT, USE OF
PICTOGRAMS, FINISH & CONTRAST.
2 SIGN FINISHES, STYLES & COLORS ARE LOCATED ON
THE MATERIAL & COLOR SCHEDULE LOCATED ON THE
IN001 SERIES DRAWINGS. EXTERIOR SIGNS ARE TO
MATCH BASE STANDARDS.
3 UNLESS NOTED OTHERWISE, TEXT ON SIGNS ARE IN
ALL CAPS.
4 SIGNS MOUNTED ON GLASS TO HAVE MATCHING
BACKER PLATE OF THE SAME SHAPE AS THE SIGN AND
SHALL MATCH THE COLOR OF THE SIGN.
5 SIGNS MOUNTED ON THE EXTERIOR MUST BE
CONSTRUCTED OF DURABLE FACTORY-FINISHED
BAKED ENAMEL WITH REFLECTIVE SHEETING.
FASTENERS SHALL BE CONCEALED AND RUST PROOF.
6 PROVIDE REQUIRED MOUNTINGS / HANGING
MECHANISMS FOR SPECIFIED SIGNS PER
MANUFACTURERS RECOMMENDATIONS FOR LOAD.
7 SURFACE APPLIED VINYL LETTERS OR GRAPHICS
THAT CAN BE RUBBED OFF OR DAMAGED AND
EXPOSED PAPER INSERTS ARE PROHIBITED.
8 CONTRACTOR TO PROVIDE SOFTWARE, ADDITIONAL
MESSAGE SLOTS FOR FUTURE INSERTS & ATTIC
STOCK FOR SIGNS; COORDINATE WITH OWNER.
9 INTERIOR MODULAR SIGNS TO HAVE REMOVABLE END
CAPS WITH PAPER CARRIERS FOR IN-HOUSE PRINTING
CAPABILITY. NOT APPLICABLE FOR EXTERIOR USE.
10 MAXIMUM OCCUPANCY SIGNAGE (TYPE L WITH
PRINTED INSERT) LOCATIONS ARE DESIGN
SUGGESTIONS ONLY; CONFIRM LOCATIONS &
QUANTITIES WITH LOCAL JURISDICTION & OWNER,
REQUIRED PER LIFE SAFETY.
11 CONTRACTOR TO CONFIRM THAT THE USER HAS
REVIEWED AND APPROVED ALL SIGNAGE MESSAGE
VERBIAGE, FINAL ROOM NUMBERS AND FINAL ROOM
NAMES; PRIOR TO ORDERING AND INSTALLATION OF
SIGNAGE PACKAGE.
12 EXTERIOR SIGNS MUST CONFORM TO
MANUFACTURER RECOMMENDATIONS FOR
APPLICATION AND ARE APPROVED BY OWNER.
13 EXTERIOR BUILDING NUMBER IDENTIFICATION SIGNS
(TYPE C) FOR EMERGENCY VEHICLES (NOT LOCATED
ON PLAN), ARE LOCATED IN FIELD FOR VISIBILITY BY
SECURITY AND FIRE PERSONNEL. COORDINATE
LOCATION AND QUANTITIES WITH OWNER AND LOCAL
JURISDICTION.
14 DIRECTIONAL SIGNS ARE DESIGN SUGGESTIONS
ONLY. ALL INFORMATION, INCLUDING ROOM NAMES
AND NUMBERS, DIRECTIONS, ETC; MUST BE
COORDINATED IN FIELD WITH OWNER PRIOR TO
ORDERING AND INSTALLATION. NOTIFY ARCHITECT OF
RECORD OF ANY IN FIELD IDENTIFICATION &
NUMERICAL CHANGES.
15 CONTRACTOR TO COORDINATE WITH LOCAL
JURISDICTION & OWNER ANY HAZARDOUS MATERIAL
SIGNS AND THE IDENTIFYING NUMBER ASSOCIATED
WITH EACH SIGN LOCATION IN ACCORDANCE TO NFPA
704.
16 CONTRACTOR TO PROVIDE FLAG SIGNS INDICATING
DEFIBRILLATOR LOCATIONS, MOUNTED ABOVE EACH
DEFIBRILLATOR.
17 CONTRACTOR TO PROVIDE FLAG SIGNS INDICATING
FIRE EXTINGUISHER LOCATIONS, MOUNTED ABOVE
EACH EXTINGUISHER.
18 CONTRACTOR TO PROVIDE HOURS OF OPERATION
VINYL GRAPHIC FOR MAIN ENTRANCE DOORS.
COORDINATE FINAL HOURS OF OPERATIONS WITH
OWNER.
19 SEE TELECOMM & SECURITY DRAWINGS FOR DEVICE
RELATED SIGNAGE.
20 CONTRACTOR TO PROVIDE ANY ADDITIONAL
REQUIRED SAFETY FLOOR STRIPING IN HANGAR BAY.
COORDINATE WITH BASE PROPERTY AND
CONTRACTING OFFICER.
21 MORALE AND/OR MISSION SPECIFIC SIGNAGE TO BE
PROVIDED BY THE OWNER AND IS NOT INCLUDED IN
THIS SIGNAGE PACKAGE. CONTRACTOR TO
COORDINATE WITH OWNER ANY ADDITIONAL SIGNAGE
REQUIREMENTS.
LEGEND - SIGNAGE
A BUILDING ENTRANCE 1
B BUILDING NUMBER 1
D.1 ROOM ID - INTERIOR 12
D.2 ROOM ID - EXTERIOR 18
F.1 MENS LOCKER ROOM 1
F.2 WOMENS LOCKER ROOM 1
G.1 SHOWERS 2
G.2 EYEWASH 10
H BUILDING DIRECTORY 1
J DRINKING FOUNTAIN 1
K.1 MENS TOILET 1
K.2 WOMENS TOILET 1
K.3 UNISEX TOILET 1
L.1 MANDATORY 5
L.2 MANDATORY LARGE 3
M.1 DIRECTIONAL 1
N NO SMOKING 15
P EXIT 17
R.1 FLOOR WARNING SIGN -
HAZARDOUS AREA
R.2 WARNING SIGN - RESTRICTED AREA 21
R.4 WARNING SIGN - HANGAR DOOR
CONTROL
S FIRE PROTECTION FOAM SYSTEM 10
T FIRE PROTECTION FOAM RELEASE 10
TOTAL QUANTITY: 136
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
1st SPECIAL
FORCES
ATTACHMENT
DELTA
To Be Determined To Be Determined To Be Determined To Be Determined
To Be Determined
NOTE: MOUNTING OPTIONS VARY PER SIGN
TYPE. MOST INTERIOR SIGNS CAN BE
EASILY INSTALLED USING A COMBINATION
OF CLEAR SILICONE ADHESIVE AND DOUBLE
SIDED FOAM TAPE OR CONCEALED
MECHANICAL FASTENERS.
WHERE THERE IS LESS THAN 18" CLEAR
SPACE ON THE LATCH SIDE OF A SINGLE
DOOR, OR ON THE RIGHT SIDE OF DOUBLE
DOORS, SIGNS SHALL BE LOCATED ON THE
NEAREST ADJACENT WALL.
WHERE THERE IS A SIDE LIGHT WINDOW
LOCATED ADJACENT TO THE DOOR,
MOUNT THE SIGN TO THE GLASS AND
PROVIDE A MATCHING BACKER PLATE OF
THE SAME SHAPE AS THE SIGN ON THE
GLASS TO CONCEAL MOUNTING DEVICE.
TEXT SHOWN ON SIGNS ARE EXAMPLES
AND ARE NOT INTENDED FOR DESIGN
PURPOSES.
ROOMS ALTERNATE ENTRANCES
EXIT
3"
M
IN
. T O B O T T O M O F T E X T
M A X . T O B O T T O M O F T E X T
1' - 0"
4'
TBD
C5/C17
AIR FORCE
MAINTENANCE
HANGAR
DOVER, DE
HELVETICA NEUE 75 HEAVY
HELVETICA NEUE 75
HEAVY
3" 1/ 4"
1/ 4"
1/ 4"
1/ 4"
1/ 4"
1/ 8"
1/ 4"
3/ 4"
3/ 4"
3/ 4"
3/ 8"
3/8"
BUILDING NUMBER,
HELVETICA NEUE 85 HEAVY
HELVETICA NEUE 65 MEDIUM
NOTE: IDENTIFICATION TO BE FROSTED OR WHITE
VINYL APPLIED TO FRONT ENTRANCE GLASS.
SEE UFC 3-120-01 FOR DETAILS.
NOTE: SIGN IS A METAL PANEL
COLORED BROWN WITH WHITE
REFLECTIVE LETTERS AND NO
BORDER. SIGN IS TO INCLUDE
THE BUILDING ADDRESS. THIS
SIGN IS MOUNTED IN THE VICINITY
OF THE FRONT DOOR AND MUST
BE COORDINATED PRIOR TO
INSTALLATION.
7"
1' - 2"
STREET NO.
TOWN, STATE
NOTE: EXTERIOR 911 EMERGENCY SIGN. BUILDING NUMBERS ARE LOCATED ON A
METAL PANEL COLORED WHITE WITH BROWN REFLECTIVE LETTERS AND NO BORDER.
CONFIRM BUILDING NUMBER AND MOUNTING LOCATION WITH OWNER PRIOR TO
ORDERING AND INSTALLATION. SIGN IS NOT LOCATED ON PLANS
2' - 4"
8"
To Be Determined To Be Determined To Be Determined To Be Determined
PRINTED PAPER INSERT WITH
ROOM NAME
8 1/2"
9"
3" 6"
9"
1-1/2" TACTILE ROOM
NUMBER WITH BRAILLE
HELVETICA NUEUE 55 ROMAN
3/4" TACTILE HELVETICA
NEUE 55 ROMAN
REMOVABLE END CAPS
PHOTOPOLYMER SIGN
AND TEXT
1-1/2" TACTILE ROOM
NUMBER WITH BRAILLE
HELVETICA NEUE 55 ROMAN
9"
3"
SHOWER
INTERNATIONAL SYMBOL
OF ACCESSIBILITY
3/4" PRINTED MESSAGE
HELVETICA NEUE 55
ROMAN WITH BRAILLE
REMOVABLE END CAPS
5 1/2"
6"
7" 2"
9"
DRINKING
FOUNTAIN
HUMAN FIGURE USING
DRINKING FOUNTAIN
3/4" PRINTED MESSAGE
HELVETICA NEUE 55
ROMAN WITH BRAILLE
REMOVABLE END CAPS
5 1/2"
6"
6" 3"
9"
NAME OF FACILITY
LOCATION OF FACILITY
NOTE: CONTRACTOR TO VERIFY BUILDING DIRECTORY VERBIAGE WITH
GOVERNMENT. MOUNT 6'-6" FROM TOP OF FINISHED FLOOR TO TOP OF SIGN.
4' - 0"
/2
3" 1' - 6" 3" 3" 1' - 6" 3"
3'
2"1"
2" 3"
-1 /2 M E S S . S T R
IP
S
WOMENS
LOCKER
ROOM
1" TACTILE ROOM DESCRIPTION
WITH BRAILLE. HELVETICA
NEUE 55 ROMAN.
INTERNATIONAL SYMBOL
OF ACCESSIBILITY
REMOVABLE END CAPS
8 1/2"
9"
8"
MENS
LOCKER
ROOM
1" TACTILE ROOM DESCRIPTION
WITH BRAILLE. HELVETICA
NEUE 55 ROMAN.
INTERNATIONAL SYMBOL
OF ACCESSIBILITY
REMOVABLE END CAPS
8 1/2"
9"
8"
MEN
6" SYMBOL
1" TACTILE ROOM DESCRIPTION
WITH BRAILLE. HELVETICA
NEUE 55 ROMAN.
8 1/2"
9"
8" 3"
REMOVABLE END CAPS
WOMEN
6" SYMBOL
1" TACTILE ROOM DESCRIPTION
WITH BRAILLE. HELVETICA
NEUE 55 ROMAN.
8 1/2"
9"
8" 3"
REMOVABLE END CAPS
UNISEX
6" SYMBOLS
1" TACTILE ROOM
DESCRIPTION WITH
BRAILLE. HELVETICA
NEUE 55 ROMAN.
8 1/2"
9"
8" 3"
REMOVABLE END CAPS
PRINTED PAPER
INSERT (INTERIOR
USE ONLY)
6"
5 1/2"
6"
REMOVABLE END CAPS
PRINTED PAPER
INSERT (INTERIOR
USE ONLY)
8"
8 1/2"
REMOVABLE END CAPS
3" MESSAGE INSERT PANELS
WITH TACTILE 1-1/2" ARROWS
AND 1" MESSAGE TEXT,
HELVETICA NEUE 65 MEDIUM
BREAK ROOM←
RESTROOMS / LOCKERS
HANGAR BAY
1' - 7 1/2"
1' - 8"
9"
REMOVABLE END CAPS
SMOKING NOT
PERMITTED WITHIN 50
FEET OF BUILDING.
NON SMOKING SYMBOL
1/2" PRINTED MESSAGE
HELVETICA NEUE 55
ROMAN WITH BRAILLE
NOTE: EXTERIOR USE
9"
6" 3"
9"
EXIT
3/4" TACTILE TEXT WITH
BRAILLE, HELVETICA NEUE
55 ROMAN.
NOTE: MOUNT SIGN ON DOOR.
8 1/2"
9"
3"
REMOVABLE END CAPS
30' - 0"
8"
1'
1'
7' - 0"
CENTERLINE OF HANGAR
DOOR AND WARNING SIGN
DANGER
HAZARDOUS AREA - STAND CLEAR DURING DOOR OPERATION
WHITE PAINTED LETTERS,
HELVETICA BOLD UPPER CASE
RED TEXT
BLACK TEXT
BLACK TEXT
WARNING
Restricted Area It is unlawful to enter this area without permission of the Installation Commander.
Sec. 21, Internal Security Act of 1950; 50 U.S.C 797
While on this Installation all personnel and the property under their control are subject to search.
Use of deadly force authorized.
Prescribed by AFI 31-101 Supersedes AFVA 31-101 14 July 1995 Distribution: F
AFVA 31-107
15 October 2000
U.S. Government Printing Office 2006-325-126
BLACK TEXT
BLACK TEXT
RED TEXT
BLACK TEXT
1'
1' - 6"
DANGER
ONLY QUALIFIED PERSONNEL
AUTHORIZED BY THE SQUADRON
COMMANDER MAY OPERATE
HANGAR DOORS
1/ 2"
3" 1/ 4"
5" 1/ 4"
1'
2' - 0"
EQ EQ
HANGAR DOOR CONTROL PANEL & CONTROL STATION
1/4" THICK MATTE ACRYLIC
3" HIGH, 1/32" THICK ACRYLIC
LETTERS, HELVETICA BOLD
UPPER CASE
1" HIGH, 1/32" THICK ACRYLIC
LETTERS, HELVETICA BOLD
UPPER CASE
NOTE: FINAL SIGN LOCATION IS
DETERMINED BY HANGAR DOOR
CONTROL PANEL LOCATION
STOP
FOAM
SYSTEM
STOP
1" HIGH RED
BLOCK LETTERING
WATER CONDUIT
(BY OTHERS)
SIGN TO HAVE WHITE
BACKGROUND COLOR
WITH MINIMUM 1/2"
WIDE BLUE BORDER
DRAIN OUTLET
(BY OTHERS)
STOP
TO STOP FOAM SYSTEM,
PRESS AND CONTINUOUSLY
HOLD "STOP" BUTTON UNTIL
RELIEVED BY EMERGENCY
RESPONDERS, THERE MAY
BE UP TO A 30 SECOND
DELAY AFTER PRESSING
THE STOP BUTTON BEFORE
THE FOAM STOPS.
PUSH
BLUE ABORT STATION WITH
CLEAR TAMPER COVER (BY
OTHERS)
START
FOAM
START
FOAM
SYSTEM
MINIMUM 20"MINIMUM 20" .
SIGNS TO BE SPACED
MAXIMUM 12" APART
M
IN
IM
U M 4"
SIGN TO HAVE
YELLOW OR
LIME / YELLOW
BACKGROUND
COLOR YELLOW MANUAL RELEASE
STATION WITH CLEAR TAMPER
COVER WITH AUDIBLE ALARM
(BY OTHERS)
1" HIGH
GREEN
BLOCK
LETTERING
3" HIGH BLUE
BLOCK LETTERING
1/2" HIGH BLACK
BLOCK LETTERING
3" HIGH
RED
BLOCK
LETTERING
NOTE: COORDINATE FINAL LOCATION WITH FIRE PROTECTION DRAWINGS AND IN-FIELD EQUIPMENT PRIOR TO MOUNTING.
EYEWASH
3/4" PRINTED MESSAGE
HELVETICA NEUE 55
ROMAN WITH BRAILLE
REMOVABLE END CAPS
5 1/2"
6"
7" 2"
9"
FOAM RELEASE
WHEN ILLUMINATED
MINIMUM 3" HIGH RED
BLOCK LETTERING
SIGN TO HAVE YELLOW
OR LIME / YELLOW
BACKGROUND COLOR
SIGN TO BE MOUNTED ABOVE EACH FOAM SYSTEM BLUE ROTARY
BEACON, SEE FIRE PROTECTION DRAWINGS FOR COORDINATION.
COORDINATE FINAL SIZE REQUIREMENTS WITH LOCAL JURISDICTION.
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
1 2 3 4 5
/1
/2
:4
:0
P M
IG501
S
IG
N A
G E
D E
T A
IL
S
I N
S T
A L
L A
T
IO
N
T Y
P E
S A
.1
S
A L M
R D
T
L J B
R T
A
D
E C
D
E C
SCALE: 1/2" = 1'-0"IG501
1 SIGN INSTALLATION DETAILS
SCALE: NTSIG501
2 BUILDING ENTRANCE - TYPE A
IN111 SCALE: NTSIG501
3 BUILDING NUMBER - TYPE B
IN111 SCALE: NTSIG501
4 911 BUILDING NUMBER - TYPE C
SCALE: NTSIG501
5 ROOM ID INTERIOR - TYPE D.1
IN111
SCALE:
1' - 0" 2' - 0" 4' - 0"
0' - 0 1/2" = 1' - 0"
SCALE: NTSIG501
6 ROOM ID EXTERIOR - TYPE D.2
IN111 SCALE: NTSIG501
9 SHOWERS - TYPE G.1
IN111
SCALE: NTSIG501
12 DRINKING FOUNTAIN - TYPE J
IN111
SCALE: NTSIG501
11 BUILDING DIRECTORY - TYPE H
IN111SCALE: NTSIG501
8 WOMENS LOCKER ROOM - TYPE F.2
IN111SCALE: NTSIG501
7 MENS LOCKER ROOM - TYPE F.1
IN113
SCALE: NTSIG501
13 MENS TOILET - TYPE K.1
IN113 SCALE: NTSIG501
14 WOMENS TOILET - TYPE K.2
IN111 SCALE: NTSIG501
15 UNISEX TOILET - TYPE K.3
IN111 SCALE: NTSIG501
16 MANDATORY SMALL- TYPE L.1
SCALE: NTSIG501
17 MANDATORY LARGE - TYPE L.2
SCALE: NTSIG501
18 DIRECTIONAL - TYPE M.1
IN111 SCALE: NTSIG501
196 NO SMOKING - TYPE N
IN111 SCALE: NTSIG501
20 EXIT - TYPE P
IN111 SCALE: NTSIG501
21 FLOOR WARNING SIGN - TYPE R.1
IN112
SCALE: NTSIG501
22 WARNING SIGN - TYPE R.2
IN111 SCALE: NTSIG501
23 WARNING SIGN - TYPE R.4
IN111 SCALE: NTSIG501
24 TYPE S - FP FOAM SYSTEM
IN111
SCALE: NTSIG501
10 SHOWERS - TYPE G
IN111
SCALE: NTSIG501
19 TYPE T - FP FOAM RELEASE
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
IG501
IG501 IG501
IG501
IG501
30"D x 72"L x 29"H D SHAPE DESK WITH TOP, END
PANEL, SUPPORT PANEL & SUPPORT COLUMN
24"D x 48"L BRIDGE W/ CENTER GROMMET
FILE / FILE SUPPORTING PEDESTAL
BOX / BOX / FILE SUPPORTING PEDESTAL
6 CENTER DRAWER
72"W x 14"D OVERHEAD STORAGE W/ TASKLIGHT
7 WORKSURFACE MOUNTED TACK BOARD
8 WORKSURFACE CORNER PIECE
9 72"L x 24"W REAR CREDENZA W/ TWO GROMMETS
D1R - U SHAPED DESK RIGHT RETURN
D1L - U SHAPED DESK LEFT RETURN
8' - 6"
6'
8' - 6"
6'
D2R - L SHAPED DESK RIGHT RETURN
30"D x 72"L x 29"H D SHAPE DESK WITH TOP, END PANEL, SUPPORT
PANEL, CENTER GROMMET, PARTIAL MODESTY PANEL
BOX / BOX / FILE SUPPORTING PEDESTAL
CENTER DRAWER
60" W WORKSURFACE MOUNTED TACK BOARD
72"W x 14"D OVERHEAD STORAGE W/ TASKLIGHT
66" W WORKSURFACE MOUNTED TACK BOARD
54"L X 24"D X 29"H RETURN WITH FULL END
PANEL, FULL MODESTY PANEL
6' - 0"
7'
6' - 0"
7'
D2L - L SHAPED DESK LEFT RETURN
24"D x 66"L x 29"H D SHAPE DESK WITH TOP, END PANEL, SUPPORT
PANEL, CENTER GROMMET, PARTIAL MODESTY PANEL
BOX / BOX / FILE SUPPORTING PEDESTAL
CENTER DRAWER
72" W WORKSURFACE MOUNTED TACK BOARD
72"W x 14"D OVERHEAD STORAGE W/ TASKLIGHT
60" W WORKSURFACE MOUNTED TACK BOARD
72"L X 30"D X 29"H RETURN WITH FULL END
PANEL, FULL MODESTY PANEL
5' - 6"
8'
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
1 2 3 4 5
/1
/2
:4
:1
P M
IF001
IN
T
E R
IO
R
F U
R N
IT
U
R E
D E
T A
IL
E
D N
O T
E S
, L E
G E
N D
S
D E
S K
T Y
P
IC
A L
S
A L M
R D
T
L J B
R T
A
D
E C
D
E C
LEGEND - FURNITURE, FIXTURES & EQUIPMENT (FF&E)
TAG DESCRIPTION QUANTITY OWNERSHIP
BB1 ENCLOSED BULLETIN BOARD 1 CFCI
CH1 TASK CHAIR 10 FF&E PACKAGE
CH2 SIDE CHAIR 4 FF&E PACKAGE
CH3 BREAK ROOM CHAIR 54 FF&E PACKAGE
CH4 ESD WORK STOOL 2 FF&E PACKAGE
CH5 WORK STOOL 5 FF&E PACKAGE
CK1 SPILL CONTAINMENT KIT 4 FF&E PACKAGE
CM1 COFFEE MAKER NON-PLUMBED 1 USER PROVIDED
D1L U SHAPED DESK - LEFT RETURN 1 FF&E PACKAGE
D1R U SHAPED DESK - RIGHT RETURN 1 FF&E PACKAGE
D2L L SHAPED DESK - LEFT RETURN 1 FF&E PACKAGE
D2R L SHAPED DESK - RIGHT RETURN 6 FF&E PACKAGE
D3 L SHAPED DESK 1 FF&E PACKAGE
EQ1 MULTIFUNCTION PRINTER 5 GFGI
EQ2 COMPUTER MONITOR & KEYBOARD 12 GFGI
EQ3 DESKTOP PHONE 12 GFGI
ER1 FREESTANDING ELECTRIC OVEN RANGE 1 UFUI
FS1 FLAMMABLE STORAGE CABINET -RED - 65"H 2 FF&E PACKAGE
GD1 GARBAGE DISPOSAL 1 CFCI
HS1 HAZARDOUS STORAGE CABINET - YELLOW 65"H 2 FF&E PACKAGE
IM1 ICE MAKER - BUILT IN 1 CFCI
IS1 INDUSTRIAL SHLEVING - 48"D X 24"D 33 FF&E PACKAGE
LF1 5H LATERAL FILE 2 FF&E PACKAGE
LF2 2H LATERAL FILE 1 FF&E PACKAGE
LF3 42"W 2H LATERAL FILE 2 FF&E PACKAGE
MB1 MARKERBOARD 3 CFCI
MB2 4FT MARKERBOARD 1 CFCI
MW1 COUNTER TOP MICROWAVE 1 UFUI
MW2 WALL MOUNTED MICRO/RANGE HOOD 1 CFCI
R1 SMALL RECYCLING BIN 10 FF&E PACKAGE
R2 LARGE RECYCLING BIN 6 FF&E PACKAGE
RF1 BOTTOM FREEZER REFRIGERATOR 4 UFUI
SC1 STORAGE CABINET 4 FF&E PACKAGE
SC2 HEAVY DUTY STORAGE CABINET W/ ROLL OUT TRAYS - 59"H 2 FF&E PACKAGE
TA1 BREAK ROOM TABLE - 96"L x 42"W 9 FF&E PACKAGE
TB1 TACKBOARD 1 CFCI
TD1 TRANSPORT DOLLY FOR CH3 1 FF&E PACKAGE
TL1 FREESTANDING TASK LIGHT 5 FF&E PACKAGE
TS1 MOBILE TOOL STORAGE - 41.25"H 6 FF&E PACKAGE
TS2 STATIONARY 12 DRAWER TOOL BOX - 59"H 2 FF&E PACKAGE
TV1 65" FLAT PANEL DISPLAY W/ WALL MOUNT 4 CFCI
TV2 49" FLAT PANEL DISPLAY W/ WALL MOUNT 1 CFCI
W1 SMALL WASTE BIN 11 FF&E PACKAGE
W2 LARGE WASTE BIN 8 FF&E PACKAGE
WB1 INDUSTRIAL WORKSTATION 5 FF&E PACKAGE
WB2 ESD WORKBENCH 2 FF&E PACKAGE
WT1 MOBILE WORKTABLE 4 FF&E PACKAGE
NOTES - INTERIOR FURNITURE
1 NOT ALL ITEMS SHOWN ON THE FURNITURE DRAWINGS ARE PART OF THE FF&E
PACKAGE. PLEASE SEE THE "OWNERSHIP" COLUMN IN THE FF&E LEGEND FOR
ITEM RESPONSIBILITY. ONLY ITEMS LISTED AS "CFCI" OR "FF&E PACKAGE" ARE
INCLUDED IN THE SEPARATE CID PACKAGE.
2 ITEMS LISTED AS 'CFCI' ARE CONTRACTOR FURNISHED AND CONTRACTOR
INSTALLED. THESE ITEMS ARE PROVIDED AS PART OF THE CONSTRUCTION
CONTRACT.
3 ITEMS LISTED AS 'GFGI' ARE GOVERNMENT FURNISHED AND GOVERNMENT
INSTALLED. THESE ITEMS ARE PROVIDED BY THE GOVERNMENT AND ARE SHOWN
FOR COORDINATION FOR THE CONTRACTOR TO PROVIDE THE REQUIRED
INFRASTRUCTURE FOR THE FUNCTION OF THE EQUIPMENT.
4 ITEMS LISTED AS 'FF&E PACKAGE' ARE PART OF A FURNITURE/EQUIPMENT
PACKAGE TO BE PROCURED SEPARATELY. THESE ITEMS ARE SHOWN FOR
COORDINATION ONLY FOR THE CONTRACTOR TO PROVIDE THE REQUIRED
INFRASTRUCTURE FOR THE FUNCTION OF THE EQUIPMENT.
5 ITEMS LISTED AS 'UFUI' ARE USER FURNISHED AND USER INSTALLED ITEMS.
THESE ITEMS ARE SHOWN FOR COORDINATION ONLY FOR THE CONTRACTOR TO
PROVIDE THE REQUIRED INFRASTRUCTURE FOR THE FUNCTION OF THE
EQUIPMENT.
6 CONTRACTOR TO PROVIDE BLOCKING FOR ALL WALL MOUNTED FF&E ITEMS AS
REQUIRED. CONFIRM SIZES AND LOCATIONS WITH GOVERNMENT
7 CONTRACTOR TO COORDINATE ELECTRICAL / DATA REQUIREMENTS, PLUMBING
REQUIREMENTS, AND STRUCTURAL BLOCKING FOR ALL FURNITURE &
EQUIPMENT.
8 FURNITURE VENDOR TO PROVIDE SIGNAGE AT EACH DESK. EACH SIGN TO
INCLUDE A TACTILE SIGN WITH DESK NUMBER AND A PRINTABLE INSERT FOR
OCCUPANTS NAME. SEE DETAIL ON IF001 FOR MORE INFORMATION
9 TVS ARE SHOWN ON THE FF&E PLANS & LEGEND ARE FOR REFERENCE ONLY.
SEE TELECOM DRAWINGS FOR SPECIFIC INFORMATION REGARDING TVS AND
WALL MOUNTS.
10 MARKERBOARDS & BULLETIN BOARDS MOUNTING HEIGHTS ARE 36" AFF TO THE
UNDER SIDE OF THE BOTTOM RAIL.
SCALE: 1/2" = 1'-0"IF001
2 DESK TYPICALS - D1L & D2R
SCALE:
1' - 0" 2' - 0" 4' - 0"
0' - 0 1/2" = 1' - 0"
SCALE: 1/2" = 1'-0"IF001
3 DESK TYPICALS - D2L & D2R
SCALE: 1/2" = 1'-0"IF001
4 DESK TYPICALS - D3
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
IF001IF001 IF001 IF001
IF111
IF113
IF113
IF
IF112
IF
IF114IF114
---IF113
IF112IF111
IF113
0.2 0.4
A
A.6
B
0.9 1 2 3 4 5
5.2
6 7 8
8.8
9 10 11 12 13
C
D
D.1
D.6
F
G
H
J
K
L
M
N
M.1
E
HANGAR
BREAKROOM
OFFICE
OFFICE
OPEN OFFICE
LOBBY
L001
TER
RESTROOM WOMEN'S
G003
RESTROOM MEN'S
G004
CORRIDOR
C002
MECHANICAL ROOM
ELEC
FUEL CELL TOOL ROOM
TOOL CRIB
MECH
FIRE PUMP AND FOAM
TANK ROOM
TR
110 ELECTRICAL ROOM
F.7F.8
1. FOR DETAILED FURNITURE INFORMATION REFER
TO CID BINDER.
2. SEE SHEET IF001 FOR FURNITURE DETAILED
NOTES, LEGENDS & DESK TYPICALS.
3. FF&E IS N.I.C. AND IS SHOWN FOR REFERENCE
ONLY.
4. CONTRACTOR TO PROVIDE BLOCKING &
COORDINATE POWER & DATA FOR ALL
MONITORS/ TVS. COORDINATE WITH ELECTRICAL
AND TELECOM DRAWINGS.
5. CONTRACTOR TO PROVIDE BLOCKING FOR ALL
MARKERBOARDS AND TACKBOARDS.
GENERAL NOTES - FURNITURE
PNN
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .