D_Gen1.pdf
PDF 3 MB Posted
- Solicitation number
- W912BU-18-R-0026
About this file
This solicitation is for construction services for an Aircraft Maintenance Hangar at Dover Air Force Base in Delaware. The project scope includes construction of an approximately 84,176 square foot single bay hangar with office, tool, and support spaces. Infrastructure such as roads, utilities, and an optional parking area are also included. The facility must achieve LEED Silver certification and have enhanced commissioning. The contract value is between $25-100 million. A site visit is scheduled for March 1, 2019, and Requests for Information are due by March 19, 2019. Proposals are due April 5, 2019. Award will be made using a tradeoff process evaluating technical and price factors. The North American Industry Classification System code is 236220 and there is no set-aside designation. The contract type is firm-fixed price with options and the duration is approximately 610 calendar days.
Drawings - 6
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 18R0026_Specs-AM2.pdf | ||
| 18R0026_Dwgs-AM2.pdf | ||
| 18-R-0026_DAFB_AMH_Pre-proposal_Site_Visit_Attendance_Roster.pdf | ||
| 18R0026_Specs-AM1R1.pdf | ||
| D_Elec10.pdf | ||
| D_Civ2.pdf | ||
| D_Structural4.pdf | ||
| RFI_Format.pdf | ||
| D_Civ3.pdf | ||
| D_Int6.pdf | ||
| D_Fire7.pdf | ||
| D_Arch5.pdf | ||
| D_Tel11.pdf | ||
| 18R0026-SpecsVol1-RTA.pdf | ||
| D_Plum8.pdf | ||
| D_Mech9.pdf | ||
| 18R0026-SpecsVol3-RTA.pdf | ||
| 18R0026-SpecsVol2-RTA.pdf |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
1 2 3 4 5
/1
/2
:2
:5
P M
G-001
C O
V E
R S
H E
E T
R S
M L
M J S
R T
A
D
E C
D
E C
DOVER AIR FORCE BASE
AIRCRAFT MAINTENANCE HANGAR
US ARMY CORPS OF ENGINEERS
PHILADELPHIA DISTRICT
RFP: W912BU-18-R-0026
PROJECT NO: FJXT133000
DOVER, DELAWARE
RTA
12 DEC 2018
VICINITY MAP
LOCATION MAP
W-5274
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
1 2 3 4 5
/1
/2
:2
:2
P M
G-002
S H
E E
T I N
D E
X
R S
M L
M J S
R T
A
D
E C
D
E C
SHEET INDEX - INTERIM DESIGN SUBMISSION...
SHEET
COUNT
SHEET INFORMATION
NUMBER NAME
ELECTRICAL
312 E-001 ELECTRICAL - NOTES, SYMBOLS, AND ABBREVIATIONS
313 ES101 ELECTRICAL - SITE UTILITY PLAN
314 ES102 ELECTRICAL - SITE UTILITY PLAN
315 ES103 ELECTRICAL - SITE UTILITY PLAN - BID OPTION
316 ES104 ELECTRICAL - SITE UTILITY PLAN - BID OPTION
317 ES110 ELECTRICAL - SITE LIGHTING PLAN
318 ES111 ELECTRICAL - SITE LIGHTING PLAN
319 ES112 ELECTRICAL - SITE LIGHTING PLAN - BID OPTION
320 ES113 ELECTRICAL - SITE LIGHTING PLAN - BID OPTION
321 ES501 ELECTRICAL - SITE DETAILS
322 ES502 ELECTRICAL - SITE DETAILS
359 TS103 TELECOMMUNICATIONS - SITE UTILITY PLAN - BID
OPTION
360 TS104 TELECOMMUNICATIONS - SITE UTILITY PLAN - BID
OPTION
323 EG110 ELECTRICAL - GROUNDING PLAN
324 EG120 ELECTRICAL - LIGHTNING PROTECTION PLAN
325 EG501 ELECTRICAL - GROUNDING DETAILS
326 EG600 ELECTRICAL - GROUNDING RISER DIAGRAM
327 EU110 ELECTRICAL - UNDERSLAB PLAN - COMPREHENSIVE
328 EU111 ELECTRICAL - UNDERSLAB PLAN - AREA A
329 EU112 ELECTRICAL - UNDERSLAB PLAN - AREA B
330 EU113 ELECTRICAL - UNDERSLAB PLAN - AREA C
331 EU114 ELECTRICAL - UNDERSLAB PLAN - AREA D
332 EU115 ELECTRICAL - UNDERSLAB PLAN - AREA E
333 EL110 ELECTRICAL - LIGHTING PLAN - COMPREHENSIVE
334 EL111 ELECTRICAL - LIGHTING PLAN - AREA A
335 EL112 ELECTRICAL - LIGHTING PLAN - AREA B
336 EL113 ELECTRICAL - LIGHTING PLAN - AREA C
337 EL114 ELECTRICAL - LIGHTING PLAN - AREA D
338 EL115 ELECTRICAL - LIGHTING PLAN - AREA E
339 EP100 ELECTRICAL - HAZARDOUS LOCATION PLAN
340 EP110 ELECTRICAL - POWER PLAN - COMPREHENSIVE
341 EP111 ELECTRICAL - POWER PLAN - AREA A
342 EP112 ELECTRICAL - POWER PLAN - AREA B
343 EP113 ELECTRICAL - POWER PLAN - AREA C
344 EP114 ELECTRICAL - POWER PLAN - AREA D
345 EP115 ELECTRICAL - POWER PLAN - AREA E
346 E-401 ELECTRICAL - ENLARGED PLANS
347 E-501 ELECTRICAL - DETAILS
348 E-502 ELECTRICAL - DETAILS
349 E-503 ELECTRICAL - DETAILS
350 E-504 ELECTRICAL - DETAILS
351 E-600 ELECTRICAL - SINGLE LINE DIAGRAM
352 E-601 ELECTRICAL - LIGHTING FIXTURE SCHEDULE AND APRON
LIGHTING AIMING GUIDE
353 E-602 ELECTRICAL - PANEL SCHEDULES
354 E-603 ELECTRICAL - PANEL SCHEDULES
355 E-604 ELECTRICAL - PANEL SCHEDULES
TELECOMMUNICATIONS
356 T-001 TELECOMMUNICATIONS - NOTES, SYMBOLS, AND
ABBREVIATIONS
357 TS101 TELECOMMUNICATIONS - SITE UTILITY PLAN
358 TS102 TELECOMMUNICATIONS - SITE UTILITY PLAN
361 T-110 TELECOMMUNICATIONS - FLOOR PLAN -
COMPREHENSIVE
362 T-111 TELECOMMUNICATIONS - FLOOR PLAN - AREA A
363 T-112 TELECOMMUNICATIONS - FLOOR PLAN - AREA B
364 T-113 TELECOMMUNICATIONS - FLOOR PLAN - AREA C
365 T-114 TELECOMMUNICATIONS - FLOOR PLAN - AREA D
366 T-115 TELECOMMUNICATIONS - FLOOR PLAN - AREA E
367 T-401 TELECOMMUNICATIONS ENLARGED PLANS
368 T-501 TELECOMMUNICATIONS DETAILS
369 T-502 TELECOMMUNICATIONS DETAILS
370 T-503 TELECOMMUNICATIONS DETAILS
371 T-601 TELECOMMUNICATIONS DIAGRAMS
SHEET INDEX - INTERIM DESIGN SUBMISSION...
SHEET
COUNT
SHEET INFORMATION
NUMBER NAME
FIRE PROTECTION
207 FA001 FIRE ALARM - GENERAL NOTES, ABBREVIATIONS, &
SYMBOLS
208 FA002 FIRE ALARM - SEQUENCE OF OPERATIONS
209 FA111 FIRE ALARM - AREA A - FLOOR PLAN
210 FA112 FIRE ALARM - AREA B - FLOOR PLAN
211 FA113 FIRE ALARM - AREA C - FLOOR PLAN
212 FA114 FIRE ALARM - AREA D - FLOOR PLAN
213 FA115 FIRE ALARM - AREA E - FLOOR PLAN
214 FA401 FIRE ALARM - ENLARGED PLANS
215 FA501 FIRE ALARM - DETAILS
216 FA701 FIRE ALARM - RISER DIAGRAM
217 FX001 FIRE PROTECTION GENERAL NOTES, ABBREVIATIONS, &
SYMBOLS
218 FX101 FIRE PROTECTION - OVERALL - FLOOR PLAN
219 FX111 FIRE PROTECTION - AREA A - FLOOR PLAN
220 FX112 FIRE PROTECTION - AREA B - FLOOR PLAN
221 FX113 FIRE PROTECTION - AREA C - FLOOR PLAN
222 FX114 FIRE PROTECTION - AREA D - FLOOR PLAN
223 FX115 FIRE PROTECTION - AREA E - FLOOR PLAN
224 FX401 FIRE PROTECTION - ENLARGED PLANS
225 FX501 FIRE PROTECTION - DETAILS
226 FX701 FIRE PROTECTION - RISER DIAGRAM
PLUMBING
227 P-001 PLUMBING GENERAL NOTES, ABBREVIATIONS &
SYMBOLS
228 PU100 PLUMBING - UNDERGROUND PLAN - COMPREHENSIVE
229 PU101 PLUMBING - UNDERGROUND PLAN - AREA A
230 PU102 PLUMBING - UNDERGROUND PLAN - AREA B
231 PU103 PLUMBING - UNDERGROUND PLAN - AREA C
232 PU104 PLUMBING - UNDERGROUND PLAN - AREA D
233 PU105 PLUMBING - UNDERGROUND PLAN - AREA E
234 PP110 PLUMBING - 1ST FLOOR PLAN - COMPREHENSIVE
235 PP111 PLUMBING - 1ST FLOOR PLAN - AREA A
236 PP112 PLUMBING - 1ST FLOOR PLAN - AREA B
237 PP113 PLUMBING - 1ST FLOOR PLAN - AREA C
238 PP114 PLUMBING - 1ST FLOOR PLAN - AREA D
239 PP115 PLUMBING - 1ST FLOOR PLAN - AREA E
240 PP116 PLUMBING - HEAT TRACING PLAN
241 P-401 PLUMBING ENLARGED PLANS
242 P-402 PLUMBING ENLARGED PLANS
243 P-403 PLUMBING ENLARGED PLANS
244 P-404 PLUMBING ENLARGED PLANS
245 P-405 PLUMBING ENLARGED PLANS
246 P-501 PLUMBING DETAILS
247 P-502 PLUMBING DETAILS
248 P-503 PLUMBING DETAILS
249 P-601 PLUMBING SCHEDULES
250 P-602 PLUMBING SCHEDULES
251 P-701 PLUMBING SANITARY RISERS
252 P-702 PLUMBING SANITARY RISERS
253 P-703 PLUMBING OIL-LADEN WASTE RISER
254 P-704 PLUMBING WATER RISERS
255 P-705 PLUMBING WATER RISERS
256 P-706 PLUMBING WATER RISERS
257 P-707 PLUMBING COMPRESSED AIR RISERS
258 P-708 PLUMBING COMPRESSED AIR RISERS
259 P-709 PLUMBING NATURAL GAS RISERS
260 P-710 PLUMBING RISERS DIAGRAMS
261 P-711 PLUMBING RISER DIAGRAMS
MECHANICAL
262 M-001 MECHANICAL SYMBOLS AND ABBREVIATIONS
263 M-002 MECHANICAL GENERAL NOTES
264 MH110 HVAC - 1ST FLOOR PLAN - COMPREHENSIVE
265 MH111 HVAC - 1ST FLOOR PLAN - AREA A
266 MH112 HVAC - 1ST FLOOR PLAN - AREA B
267 MH113 HVAC - 1ST FLOOR PLAN - AREA C
268 MH114 HVAC - 1ST FLOOR PLAN - AREA D
269 MH115 HVAC - 1ST FLOOR PLAN - AREA E
270 MP110 PIPING - 1ST FLOOR PLAN - COMPREHENSIVE
271 MP111 PIPING - 1ST FLOOR PLAN - AREA A
272 MP112 PIPING - 1ST FLOOR PLAN - AREA B
273 MP113 PIPING - 1ST FLOOR PLAN - AREA C
274 MP114 PIPING - 1ST FLOOR PLAN - AREA D
275 MP115 PIPING - 1ST FLOOR PLAN - AREA E
276 M-121 MECHANICAL - ROOF PLAN
277 M-301 MECHANICAL - SECTIONS
278 M-302 MECHANICAL - SECTIONS
279 M-303 MECHANICAL - SECTIONS
280 M-401 MECHANICAL - ENLARGED PLAN
281 M-402 MECHANICAL - ENLARGED PLAN
282 M-403 MECHANICAL - ENLARGED PLAN
283 M-501 MECHANICAL DETAILS
284 M-502 MECHANICAL DETAILS
285 M-503 MECHANICAL DETAILS
286 M-504 MECHANICAL DETAILS
287 M-505 MECHANICAL DETAILS
288 M-601 MECHANICAL SCHEDULES
289 M-602 MECHANICAL SCHEDULES
290 M-603 MECHANICAL SCHEDULES
291 M-604 MECHANICAL SCHEDULES
292 M-605 MECHANICAL SCHEDULES
293 M-606 MECHANICAL SCHEDULES
294 M-607 MECHANICAL SCHEDULES
295 M-608 MECHANICAL SCHEDULES
296 M-701 HVAC - HOT WATER FLOW DIAGRAM
297 M-702 HVAC - CHILLED WATER FLOW DIAGRAM
298 M-800 HVAC CONTROLS
299 M-801 HVAC CONTROLS
300 M-802 HVAC CONTROLS
301 M-803 HVAC CONTROLS
302 M-804 HVAC CONTROLS
303 M-805 HVAC CONTROLS
304 M-806 HVAC CONTROLS
305 M-807 HVAC CONTROLS
306 M-808 HVAC CONTROLS
307 M-809 HVAC CONTROLS
308 M-810 HVAC CONTROLS
309 M-811 HVAC CONTROLS
310 M-812 HVAC CONTROLS
311 M-901 MECHANICAL ISOMETRIC VIEWS
SHEET INDEX - INTERIM DESIGN SUBMISSION...
SHEET
COUNT
SHEET INFORMATION
NUMBER NAME
104 SF315 ROOF (TRUSS TOP CHORD) FRAMING PLAN - AREA E
105 SF316 HIGH ROOF FRAMING PLAN
106 S-201 ELEVATION - GRID A
107 S-202 ELEVATION - GRID B
108 S-203 ELEVATION - GRIDS C, D & E
109 S-204 ELEVATION - GRID F
110 S-205 ELEVATION - GRIDS G, H & J
111 S-206 ELEVATION - GRID K
112 S-207 ELEVATION - GRIDS L & M, N
113 S-208 ELEVATION - GRIDS 1, 13
114 S-209 ELEVATION - GRIDS 5 & 9, 5.2 & 8.8
115 S-210 ELEVATION - GRIDS 4 & 10, 6 & 8
116 S-211 ELEVATION - GRIDS 2 & 12, 3 & 11
117 S-212 ELEVATION - GRID 7
118 S-301 FOUNDATION SECTIONS
119 S-311 FRAMING SECTIONS
120 S-312 FRAMING SECTIONS
121 S-313 FRAMING SECTIONS
122 S-314 FRAMING SECTIONS
123 S-411 CATWALK FRAMING PLANS
124 S-501 FOUNDATION TYPICAL DETAILS
125 S-502 FOUNDATION TYPICAL DETAILS
126 S-503 FOUNDATION TYPICAL DETAILS
127 S-511 FRAMING TYPICAL DETAILS
128 S-512 FRAMING TYPICAL DETAILS
129 S-521 TRUSS CONNECTION DETAILS
130 S-522 TRUSS CONNECTION DETAILS
131 S-523 TRUSS CONNECTION DETAILS
132 S-524 TRUSS CONNECTION DETAILS
133 S-525 TRUSS CONNECTION DETAILS
134 S-526 TRUSS CONNECTION DETAILS
135 S-531 VERTICAL BRACING DETAILS
136 S-532 VERTICAL BRACING DETAILS
137 S-533 VERTICAL BRACING DETAILS
138 S-541 HORIZONTAL BRACING DETAILS
139 S-542 HORIZONTAL BRACING DETAILS
140 S-551 GIRT DETAILS
141 S-601 FOUNDATION SCHEDULES
142 S-602 COLUMN SCHEDULE
143 S-701 WIND LOAD DIAGRAM
ARCHITECTURE
144 A-001 ARCHITECTURAL GENERAL NOTES & LEGENDS
145 A-002 TYPICAL ADA DETAILS
146 A-110 COMPREHENSIVE FLOOR PLAN
147 A-111 AREA A - FLOOR PLAN
148 A-112 AREA B - FLOOR PLAN
149 A-113 AREA C - FLOOR PLAN
150 A-114 AREA D - FLOOR PLAN
151 A-115 AREA E - FLOOR PLAN
152 A-120 COMPREHENSIVE ROOF PLAN
153 AR110 COMPREHENSIVE REFLECTED CEILING PLAN
154 AR111 AREA A - REFLECTED CEILING PLAN
155 AR112 AREA B - REFLECTED CEILING PLAN
156 AR113 AREA C - REFLECTED CEILING PLAN
157 AR114 AREA D - REFLECTED CEILING PLAN
158 AR115 AREA E - REFLECTED CEILING PLAN
159 AR200 DRAFT CURTAINS
160 A-200 EXTERIOR FINISH SCHEDULE
161 A-201 COMPREHENSIVE BUILDING ELEVATIONS
162 A-202 COMPREHENSIVE BUILDING ELEVATIONS
163 A-301 BUILDING SECTIONS
164 A-310 WALL SECTIONS
165 A-311 WALL SECTIONS
166 A-312 WALL SECTIONS
167 A-401 ENLARGED RESTROOM PLANS
168 A-402 ENLARGED BREAKROOM PLANS
169 A-403 EQUIPMENT PLATFORM
170 A-404 EQUIPMENT PLATFORM
171 A-405 EQUIPMENT PLATFORM
172 A-406 EQUIPMENT PLATFORM
173 A-501 ARCHITECTURAL DETAILS
174 A-502 ARCHITECTURAL DETAILS
175 A-503 ARCHITECTURAL DETAILS
176 A-504 ARCHITECTURAL DETAILS
177 A-505 ARCHITECTURAL DETAILS
178 A-506 ARCHITECTURAL DETAILS
179 A-507 CEILING DETAILS
180 A-601 PARTITION TYPES
181 A-602 TILE & SHOWER PAN DETAILS
182 A-610 DOOR SCHEDULE
183 A-611 DOOR AND WINDOW TYPES
184 A-612 EXTERIOR AND INTERIOR WINDOW TYPES
185 A-801 CLEARANCE PLAN - C5
186 A-802 CLEARANCE SECTION - C5
187 A-803 CLEARANCE PLAN - C17
188 A-804 CLEARANCE SECTION - C17
189 A-805 AIR BARRIER PLAN
190 A-806 AIR BARRIER SECTION
INTERIORS
191 IN001 INTERIOR FINISH DETAILED NOTES, LEGENDS &
SCHEDULES
192 IN110 COMPREHENSIVE - FINISH PLAN
193 IN111 FINISH & SIGNAGE - 1ST FLOOR PLAN - AREA A
194 IN112 FINISH & SIGNAGE - 1ST FLOOR PLAN - AREA B
195 IN113 FINISH & SIGNAGE - 1ST FLOOR PLAN - AREA C
196 IN114 FINISH & SIGNAGE - 1ST FLOOR PLAN - AREA D
197 IN115 FINISH & SIGNAGE - 1ST FLOOR PLAN - AREA E
198 IN501 ENLARGED - INTERIOR FINISH PLANS & DETAILS
199 IG001 SIGNAGE DETAILED NOTES, LEGENDS & SCHEDULES
200 IG501 SIGNAGE DETAILS - INSTALLATION & TYPES A.1 - S
201 IF001 INTERIOR FURNITURE DETAILED NOTES, LEGENDS &
DESK TYPICALS
202 IF110 COMPREHENSIVE - FURNITURE PLAN
203 IF111 FURNITURE - 1ST FLOOR PLAN - AREA A
204 IF112 FURNITURE - 1ST FLOOR PLAN - AREA B
205 IF113 FURNITURE - 1ST FLOOR PLAN - AREA C
206 IF114 FURNITURE - 1ST FLOOR PLAN-AREA E
SHEET INDEX - INTERIM DESIGN SUBMISSION...
SHEET
COUNT
SHEET INFORMATION
NUMBER NAME
GENERAL
1 G-001 COVER SHEET
2 G-002 SHEET INDEX
3 G-100 LIFE SAFETY - CODE ANALYSIS
4 G-101 LIFE SAFETY - FLOOR PLAN
CIVIL
5 C-001 CIVIL LEGEND AND ABBREVIATIONS
6 C-002 CIVIL GENERAL NOTES
7 C-003 LOCATION AND VICINITY MAPS
8 C-004 ACCESS ABD SAFETY PLAN
9 C-005 GENERAL ACCESS AND SAFETY NOTES
10 C-006 CONSTRUCTION PHASING PARIS STREET RELOCATION
AND UTILITY RELOCATION
11 C-007 CONSTRUCTION PHASING PLAN RAMP ROAD
RECONSTRUCTION
12 B-100 OVERALL BORING PLAN
13 B-101 BORING LOGS
14 B-102 BORING LOGS
15 B-103 BORING LOGS
16 B-104 BORING LOGS
17 V-100 OVERALL EXISTING CONDITIONS SITE PLAN
18 V-101 EXISTING CONDITIONS SITE PLAN
19 V-102 EXISTING CONDITIONS SITE PLAN
20 VD100 OVERALL SITE DEMOLITION PLAN
21 VD101 SITE DEMOLITION PLAN
22 VD102 SITE DEMOLITION PLAN
23 CS100 OVERALL SITE PLAN
24 CS101 SITE PLAN
25 CS102 SITE PLAN
26 CS103 SITE PLAN BID OPTION
27 CS104 SITE PLAN BID OPTION
28 CS201 PROPOSED ROADWAY PROFILES
29 CG100 OVERALL SITE GRADING & DRAINAGE PLAN
30 CG101 SITE GRADING & DRAINAGE PLAN
31 CG102 SITE GRADING & DRAINAGE PLAN
32 CG103 SITE GRADING & DRAINAGE PLAN BID OPTION
33 CG104 SITE GRADING & DRAINAGE PLAN BID OPTION
34 CG201 PROPOSED STORM SEWER PROFILES
35 CG202 PROPOSED STORM SEWER PROFILES
36 CG203 PROPOSED STORM SEWER PROFILES
37 CH101 HORIZONTAL CONTROL PLAN
38 CH102 HORIZONTAL CONTROL PLAN
39 CH103 HORIZONTAL CONTROL PLAN BID OPTION
40 CH104 HORIZONTAL CONTROL PLAN BID OPTION
41 CH501 HORIZONTAL CONTROL TABLE
42 CH502 HORIZONTAL CONTROL TABLE BID OPTION
43 CP100 OVERALL SITE PAVING & SIGNAGE PLAN
44 CP101 SITE PAVING & SIGNAGE PLAN
45 CP102 SITE PAVING & SIGNAGE PLAN
46 CP103 PAVEMENT JOINTING PLAN
47 CP104 SITE PAVING PLAN BID OPTION
48 CP105 SITE PAVING PLAN BID OPTION
49 CM100 OVERALL PAVEMENT MARKING AND SIGNAGE PLAN
50 CM101 PAVEMENT MARKING AND SIGNAGE PLAN
51 CM102 PAVEMENT MARKING AND SIGNAGE PLAN
52 CM103 PAVEMENT MARKING AND SIGNATE PLAN BID OPTION
53 CM104 PAVEMENT MARKING AND SIGNATE PLAN BID OPTION
54 CU100 OVERALL SITE UTILITY PLAN
55 CU101 SITE UTILITY PLAN
56 CU102 SITE UTILITY PLAN
57 CU201 PROPOSED SANITARY SEWER PROFILES
58 CE101 EROSION AND SEDIMENT CONTROL PLAN - PHASE I
59 CE102 EROSION AND SEDIMENT CONTROL PLAN - PHASE II
60 CE103 E&S CONTROL PLAN PHASE 2 WITH BID OPTION
61 C-501 STANDARD DETAILS
62 C-502 STANDARD DETAILS
63 C-503 STANDARD DETAILS
64 C-504 STANDARD DETAILS
65 C-505 STANDARD DETAILS
66 C-506 STANDARD DETAILS
67 C-507 STANDARD DETAILS
68 C-508 STANDARD DETAILS
69 C-509 STANDARD DETAILS
70 C-510 STANDARD DETAILS
71 C-511 STANDARD DETAILS
72 C-512 STANDARD DETAILS
73 C-513 STANDARD DETAILS
74 C-514 STANDARD DETAILS
75 C-515 STANDARD DETAILS
76 C-516 STANDARD DETAILS
77 C-517 STANDARD DETAILS
STRUCTURAL
78 S-001 STRUCTURAL DESIGN CRITERIA, & GENERAL NOTES
79 S-002 STRUCTURAL ABBREVIATIONS & SYMBOLS
80 S-003 STRUCTURAL SPECIAL INSPECTION TABLES
81 S-004 STRUCTURAL SPECIAL INSPECTION TABLES
82 SB110 COMPREHENISVE FOUNDATION PLAN
83 SB111 FOUNDATION PLAN - AREA A
84 SB112 FOUNDATION PLAN - AREA B
85 SB113 FOUNDATION PLAN - AREA C
86 SB114 FOUNDATION PLAN - AREA D
87 SB115 FOUNDATION PLAN - AREA E
88 SB116 HANGAR SLAB JOINT PLAN
89 SF110 COMPREHENSIVE LOW ROOF FRAMING PLAN
90 SF111 LOW ROOF FRAMING PLAN - AREA A
91 SF113 LOW ROOF FRAMING PLAN - AREA C
92 SF115 LOW ROOF FRAMING PLAN - AREA E
93 SF210 COMPREHENSIVE ROOF (BOTTOM CHORD) FRAMING
PLAN
94 SF211 ROOF (TRUSS BOTTOM CHORD) FRAMING PLAN - AREA A
95 SF212 ROOF (TRUSS BOTTOM CHORD) FRAMING PLAN - AREA B
96 SF213 ROOF (TRUSS BOTTOM CHORD) FRAMING PLAN - AREA C
97 SF214 ROOF (TRUSS BOTTOM CHORD) FRAMING PLAN - AREA D
98 SF215 ROOF (TRUSS BOTTOM CHORD) FRAMING PLAN - AREA E
99 SF310 COMPREHENSIVE ROOF (TOP CHORD) FRAMING PLAN
100 SF311 ROOF (TRUSS TOP CHORD) FRAMING PLAN - AREA A
101 SF312 ROOF (TRUSS TOP CHORD) FRAMING PLAN - AREA B
102 SF313 ROOF (TRUSS TOP CHORD) FRAMING PLAN - AREA C
103 SF314 ROOF (TRUSS TOP CHORD) FRAMING PLAN - AREA D
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
FIRE PROTECTION/LIFE SAFETY/ACCESSIBILTY CODE SUBMITTAL
1. PROJECT NAME
DOVER AIR FORCE BASE, C5/C17 AIRCRAFT MAINTENANCE HANGAR.
2. PROJECT DESCRIPTION
THE HANGAR CONSISTS OF ONE HANGAR BAY, HOUSING A SINGLE AIRCRAFT. THE HANGAR
BAY IS SEPARATED FROM AN OPERATIONS AREA THAT STORES MATERIALS AND TOOLS USED
FOR AIRCRAFT MAINTENANCE AND AN ADMINISTRATION AREA THAT SUPPORTS FLIGHT
OPERATIONS. THE FACILITY HAS BEEN ANALYZED FOR LIFE SAFETY AND FIRE PROTECTION
REQUIREMENTS USING THE CODES AND STANDARDS LISTED BELOW. THE UNIFIED FACILITIES
CRITERIA (UFC) APPLIES TO THE MILITARY DEPARTMENTS, THE DEFENSE AGENCIES, AND THE
DOD FIELD ACTIVITIES WHICH PROVIDES TECHNICAL CRITERIA FOR NEW MILITARY
CONSTRUCTION. BASED ON UFC 1-200-01 CHAPTER 2 - MODIFICATIONS TO THE
INTERNATIONAL BUILDING CODE (IBC) AND UFC 3-600-01, THE IBC WILL BE USED FOR FIRE
RESISTANCE REQUIREMENTS, ALLOWABLE FLOOR AREA, BUILDING HEIGHT LIMITATIONS,
BUILDING SEPARATION DISTANCE REQUIREMENTS, BUILDING CONSTRUCTION TYPE, AND
OCCUPANCY SEPARATION REQUIREMENTS EXCEPT AS MODIFIED BY UFC 3-600-01. NFPA 101
WILL BE USED FOR BUILDING CONSTRUCTION RELATED TO EGRESS AND SAFETY TO LIFE AS
WELL AS FIRE RESISTANCE RATINGS OF NON-BEARING PARTITIONS. IF ANY CONFLICTS OCCUR
BETWEEN NFPA 101 AND IBC, RELATED TO FIRE RESISTANCE RATING, NFPA 101 WILL TAKE
PRECEDENCE AND APPLICABLE CRITERIA CONTAINED IN UFC 3-600-01. OCCUPANCY
DEFINITIONS OF NFPA 101 WILL BE USED TO DETERMINE MEANS OF EGRESS REQUIREMENTS.
3. APPLICABLE CODES AND STANDARDS
• IBC – 2015 EDITION – INTERNATIONAL BUILDING CODE
• NFPA 10 – 2013 EDITION – STANDARD FOR PORTABLE FIRE EXTINGUISHERS
• NFPA 11 – 2016 EDITION – STANDARD FOR LOW-, MEDIUM-, AND HIGH EXPANSION FOAM
• NFPA 13 – 2016 EDITION – STANDARD FOR INSTALLATION OF SPRINKLER SYSTEMS
• NFPA 24 – 2016 EDITION – STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE
MAINS AND THEIR APPURTENANCES
• NFPA 70 – 2014 EDITION – NATIONAL ELECTRICAL CODE
• NFPA 72 – 2016 EDITION – NATIONAL FIRE ALARM AND SIGNALING CODE
• NFPA 90A – 2015 EDITION – STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING &
VENTILATING SYSTEMS
• NFPA 101 – 2015 EDITION – LIFE SAFETY CODE
• NFPA 409 – 2016 EDITION – STANDARD ON AIRCRAFT HANGARS
• UFC 1-200-01 – GENERAL BUILDING REQUIREMENTS, 20 JUNE 2016
• UFC 3-600-01 – FIRE PROTECTION ENGINEERING FOR FACILITIES, 8 AUGUST 2016 WITH
CHANGE 1, 28 NOVEMBER 2016
• UFC 4-010-01 – DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, 9 FEBRUARY
2012 WITH CHANGE 1, 1 OCTOBER 2013
• UFC 4-021-01 – DESIGN AND O&M: MASS NOTIFICATION SYSTEMS, 9 APRIL 2008 WITH
CHANGE 1, JANUARY 2010
• UFC 4-211-01 – AIRCRAFT MAINTENANCE HANGARS, 13 APRIL 2017
• DOVER AIR FORCE BASE, LOCAL MILCON AND SRM DESIGN GUIDE
4. OCCUPANCY CLASSIFICATION
IBC ASSEMBLY GROUP A-3 (IBC – SECTION 303)
BUSINESS GROUP B (IBC – SECTION 304)
STORAGE GROUP S-2 (IBC -– SECTION 311)
STORAGE GROUP S-1 (IBC -– SECTION 311)
NFPA 101 ASSEMBLY OCCUPANCY (NFPA 101, CHAPTER 12)
BUSINESS OCCUPANCY (NFPA 101, CHAPTER 38)
LOW HAZARD STORAGE OCCUPANCY (NFPA 101, CHAPTER 42)
ORDINARY HAZARD STORAGE OCCUPANCY (NFPA 101, CHAPTER 42)
5. CONSTRUCTION TYPE (IBC 602.2 AND TABLE 503)
CONSTRUCTION TYPE II-B
6. AREA AND HEIGHT LIMITATIONS (UFC 4-211-01 AND IBC)
PER UFC 4-211-01 SECTION 3-3.1.6, THE ALLOWABLE BUILDING AREA IS LIMITED TO THE
RESTRICTIONS OF THE IBC. PER IBC CHAPTER 507.4, THE AREA OF A GROUP S BUILDING NO
MORE THAN ONE STORY ABOVE GRADE OF ANY CONSTRUCTION TYPE, SHALL NOT BE
LIMITED WHERE THE BUILDING IS PROVIDED WITH AN AUTOMATIC SPRINKLER SYSTEM
THROUGHOUT THE BUILDING AND IS SURROUNDED AND ADJOINED BY PUBLIC WAYS NOT
LESS THAN 60 FEET IN WIDTH. PER UFC 4-211-01 SECTION 3-3.1.6, GROUP A-3 BUILDING
NO MORE THAN THREE STORIES ABOVE GRADE OF TYPE II CONSTRUCTION, SHALL NOT
BE LIMITED IF IT DOES NOT A STAGE OR ANY OTHER PLATFORM, WHERE THE BUILDING IS
PROVIDED WITH AN AUTOMATIC SPRINKLER SYSTEM THROUGHOUT THE BUILDING, AND IS
SURROUNDED AND ADJOINED BY PUBLIC WAYS NOT LESS THAN 60 FEET IN WIDTH.
THE ALLOWABLE HEIGHT IS UNLIMITED PER UFC 4-211-01 SECTION 3-3.1.7.
7. FIRE RESISTIVE REQUIREMENTS (IBC TABLE 601 AND 602)
PRIMARY STRUCTURAL FRAME 0 HOUR RATING
EXTERIOR BEARING WALLS 0 HOUR RATING*
INTERIOR BEARING WALLS 0 HOUR RATING
EXTERIOR NON-BEARING WALLS AND PARTITIONS 0 HOUR RATING
INTERIOR NON-BEARING WALLS AND PARTITIONS 0 HOUR RATING
FLOOR CONSTRUCTION AND SECONDARY MEMBERS 0 HOUR RATING
ROOF CONSTRUCTION AND SECONDARY MEMBERS 0 HOUR RATING
*TAKES INTO ACCOUNT THE FIRE SEPARATION DISTANCE REQUIREMENT OF IBC TABLE 602
AND UFC 4-211-01. THE MINIMUM SEPARATION DISTANCE BETWEEN TYPE I OR II HANGARS
AND HANGARS OF OTHER CONSTRUCTION TYPES SHALL BE 40 FT. THIS MAY BE REDUCED
TO 25 FT. IF SEPARATED BY A 1-HOUR EXPOSURE WALL WITH OPENINGS PROTECTED WITH
SELF-CLOSING 45-MINUTE ASSEMBLIES, OR IF BOTH HANGARS ARE PROTECTED BY
APPROVED FIRE SUPPRESSION SYSTEMS. THIS MAY BE FURTHER REDUCED TO 10 FT. IF
BOTH HANGARS HAVE A 1-HOUR EXPOSURE WALL WITH OPENINGS PROTECTED WITH SELF-
LOSING 45-MINUTE ASSEMBLIES. MINIMUM SEPARATION BETWEEN HANGARS AND OTHER
BUILDINGS IS 40 FT. REDUCTIONS IN THIS DISTANCE MUST CONFORM TO THE IBC.
OCCUPANCY SEPARATIONS AND RATINGS PER UFC 4-211-01:
HANGAR BAY TO SUPPORT AREAS 1 HOUR RATING
FIRE PROTECTION EQUIPMENT ROOM 1 HOUR RATING
WHERE FIRE BARRIERS ARE PROVIDED THAT BORDER THE HANGAR BAY, PROVIDE MASONRY
CONSTRUCTION TO A MINIMUM OF 10 FT. AFF. ABOVE 20 FT. ANY UL LISTED ASSEMBLY
IS PERMITTED TO COMPLETE THE BARRIER. THE TERM MASONRY IS INCLUSIVE OF
CAST-IN-PLACE, PRE-CAST, TILT-UP, BLOCK OR OTHER SIMILAR CONCRETE CONSTRUCTION.
PROVIDE A 1-HOUR FIRE BARRIER BETWEEN HANGAR BAY AND SUPPORT AREAS
(E.G.,OFFICES, SHOPS).
8. PROTECTION FROM HAZARDS (NFPA 101, 12.3.2, 38.3.2, 42.3.2, AND NFPA 70)
HAZARDOUS AREAS INCLUDING, BUT NOT LIMITED TO, AREAS USED FOR GENERAL STORAGE,
BOILER OR FURNACE ROOMS, AND ROOMS OR SPACES USED FOR USE OF COMBUSTIBLE
SUPPLIES DEEMED HAZARDOUS BY THE AUTHORITY HAVING JURISDICTION SHALL BE
PROTECTED BY A MINIMUM SMOKE PARTITION COMPLYING WITH NFPA 101 SECTION 8.4.
ELECTRICAL ROOM IS SEPARATED FROM THE REST OF THE BUILDING BY A 1 HOUR FIRE
BARRIER DUE TO TRANSFORMER SIZE IN ACCORDANCE WITH NFPA 70 ARTICLE 450.21.
9. OPENING PROTECTION AND PENETRATION REQUIREMENTS (NFPA 101 CHAPTER 8)
PENETRATIONS FOR CABLES, CONDUITS, PIPES, AND SIMILAR ITEMS TO ACCOMMODATE
ELECTRICAL, MECHANICAL, PLUMBING, AND COMMUNICATIONS SYSTEMS THAT PASS
THROUGH FIRE BARRIERS SHALL BE PROTECTED BY APPROVED FIRESTOP SYSTEMS OR
DEVICES TESTED IN ACCORDANCE WITH ASTM E 814 OR ANSI / UL 1479.
JOINTS MADE WITHIN OR AT THE PERIMETER OF FIRE BARRIERS SHALL BE PROTECTED WITH
A JOINT SYSTEM THAT IS CAPABLE OF LIMITING THE TRANSFER OF SMOKE. JOINTS MADE
WITHIN OR BETWEEN FIRE BARRIERS SHALL BE PROTECTED WITH A SMOKE-TIGHT JOINT
SYSTEM THAT IS CAPABLE OF LIMITING THE TRANSFER OF SMOKE. JOINTS MADE WITHIN OR
BETWEEN FIRE RESISTANCE-RATED ASSEMBLIES SHALL BE PROTECTED WITH A JOINT
SYSTEM TESTED IN ACCORDANCE WITH ASTM E1966 OR ANSI / UL 2079.
PENETRATIONS AND JOINTS THROUGH SMOKE PARTITIONS SHALL BE PROTECTED BY A
SYSTEM THAT IS CAPABLE OF LIMITING THE TRANSFER OF SMOKE
COMPONENT WALLS AND PARTITIONS (HOUR)
NFPA 101 TABLE 8.3.4.2
FIRE DOOR ASSEMBLIES (HOUR)
FIRE BARRIER 1 3/4
SMOKE PARTITIONS - (SELF CLOSING)
FIREBLOCKING AND DRAFTSTOPPING ARE NOT REQUIRED IN NON-COMBUSTIBLE CONSTRUCTION PER
IBC 717.2 AND 717.3
10. MARKING AND IDENTIFICATION OF FIRE BARRIER AND SMOKE PARTITION (IBC 703.7)
FIRE BARRIERS AND SMOKE PARTITIONS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH
SIGNS OR STENCILING. SUCH IDENTIFICATION SHALL:
1. BE LOCATED IN ACCESSIBLE CONCEALED FLOOR, CEILING, OR ATTIC SPACE.
2. BE LOCATED WITHIN 15 FEET OF THE END OF EACH WALL AND AT INTERVALS NOT EXCEEDING 30
FEET MEASURED HORIZONTALLY ALONG THE WALL OR PARTITIONS.
3. INCLUDE LETTERING NOT LESS THAN 3 INCHES IN HEIGHT WITH A MINIMUM 3/8 INCH STROKE IN A
CONTRASTING COLOR INCORPORATING THE SUGGESTED WORDING “FIRE AND/OR SMOKE
PARTITION – PROTECT ALL OPENINGS” OR OTHER WORDING.
11. FIRE AND SMOKE DAMPERS (NFPA 90A)
AIR-TRANSFER OPENINGS IN A FIRE-RATED ASSEMBLY SHALL BE PROVIDED WITH APPROVED FIRE
DAMPERS.
AIR-TRANSFER OPENINGS IN SMOKE PARTITIONS SHALL BE PROVIDED WITH APPROVED SMOKE
DAMPERS.
INTERIOR FINISH CLASSIFICATION: NFPA 101 A.10.2.2
OCCUPANCY EXIT ENCLOSURES
EXIT ACCESS
CORRIDORS
OTHER SPACES
NEW ASSEMBLY -
LESS THAN 300
OCCUPANTS
NEW BUSINESS
STORAGE
CLASS A CLASS A OR B CLASS I OR II
CLASS I OR II CLASS I OR II N/A
CLASS A OR B
CLASS I OR II
CLASS A OR B
CLASS I OR II
CLASS A INTERIOR WALL AND CEILING FINISH – FLAME SPREAD INDEX 0-25, SMOKE DEVELOPED 0-450 CLASS B INTERIOR WALL AND CEILING FINISH – FLAME SPREAD INDEX 26-75, SMOKE DEVELOPED 0-450 CLASS C INTERIOR WALL AND CEILING FINISH – FLAME SPREAD INDEX 76-200, SMOKE DEVELOPED 0-450
CLASS I INTERIOR FLOOR FINISH – CRITICAL RADIANT FLUX NOT LESS THAN 0.45 W/CM2
CLASS II INTERIOR FLOOR FINISH – CRITICAL RADIANT FLUX NOT MORE THAN 0.22 W/CM2 BUT LESS
THAN 0.45 W/CM2
CLASS A OR B
N/A
CLASS A, B, OR C
N/A
CLASS A, B, OR C
N/A
CLASS A, B, OR C
N/A
NOTE: WHERE A COMPLETE STANDARD SYSTEM OF AUTOMATIC SPRINKLER SYSTEM IS
PROVIDED, INTERIOR WALL AND CEILING FINISH WITH A FLAME SPREAD RATING NOT EXCEEDING CLASS C IS PERMITTED TO BE USED IN ANY LOCATION WHERE CLASS B IS REQUIRED AND WITH A
RATING OF CLASS B IN ANY LOCATION WHERE CLASS A IS REQUIRED; SIMILARLY, CLASS II
INTERIOR FLOOR FINISH IS PERMITTED TO BE USED IN ANY LOCATION WHERE CLASS I IS
REQUIRED, AND NO CRITICAL RADIANT FLUX RATING IS REQUIRED WHERE CLASS II IS REQUIRED.
13. INSULATION REQUIREMENTS (UFC 3-600-01 SECTION 8-3)
THERMAL AND ACOUSTICAL INSULATION WITH A FLAME SPREAD (FS) RATING NOT HIGHER THAN 75, AND A SMOKE DEVELOPED (SD) RATING NOT HIGHER THAN 150 WHEN TESTED INACCORDANCE WITH ASTM E84 (NFPA 255) SHALL BE USED UNLESS THE EXCEPTIONS OF SECTIONS 2-7.2.1 OR
2-7.2.2 ARE MET.
14. MEANS OF EGRESS
EXITS WILL BE DESIGNED TO MEET NFPA 101. ALL DOORS, CORRIDORS, AND RAMPS WILL BE
SIZED AT 0.2 INCHES PER OCCUPANT USING THE EXIT.
12. INTERIOR FINISH CLASSIFICATION LIMITS
16. DISCHARGE FROM EXITS (NFPA 101, 12.2.7, 38.2.7, 42.2.7, AND 7.7)
A MINIMUM OF 50 PERCENT OF THE EXITS SHALL DISCHARGE TO THE EXTERIOR. BUILDING
EXITS SHALL TERMINATE DIRECTLY AT A PUBLIC WAY IN ACCORDANCE WITH NFPA 101,
SECTION 7.7.
17. ILLUMINATION OF MEANS OF EGRESS (NFPA 101, 12.2.8, 38.2.8, 42.2.8, AND 7.8)
MEANS OF EGRESS SHALL BE ILLUMINATED IN ACCORDANCE WITH NFPA 101 SECTION 7.8.
18. EMERGENCY LIGHTING (NFPA 101, 12.2.9, 38.2.9, 42.2.9, AND 7.9)
EMERGENCY LIGHTING SHALL BE PROVIDED IN ACCORDANCE WITH SECTION 7.9.
19. MARKING OF MEANS OF EGRESS (NFPA 101, 12.2.10, 38.2.10, 42.2.10, AND 7.10)
MEANS OF EGRESS SHALL HAVE SIGNS IN ACCORDANCE WITH SECTION 7.10.
20. PORTABLE FIRE EXTINGUISHERS (NFPA 10)
A SEMI-FLUSH MOUNTED CABINET FOR A PORTABLE CLASS K FIRE EXTINGUISHER WILL BE
LOCATED IN BREAKROOM 104 IN ACCORDANCE WITH UFC 3-600-01, NFPA 101, AND NFPA 10.
ONLY THE CABINET WILL BE PROVIDED, THE EXTINGUISHER WILL BE PROVIDED BY OTHERS.
21. FIRE HYDRANTS (UFC 4-211-01)
PER UFC 4-211-01 SECTION 3-6.4, WHERE THE AIRCRAFT PARKING APRON PAVEMENT ABUTS
THE BUILDING, FIRE HYDRANTS SHALL BE LOCATED IN THESE AREAS WITHIN 10 FEET OF THE
BUILDING, AT LEAST ONE FIRE HYDRANT SHALL BE LOCATED WITHIN 100 FEET OF EACH
CORNER OF THE HANGAR, FIRE HYDRANT SPACING SHALL NOT EXCEED 300 FEET LINEARLY
AROUND THE FACILITY PERIMETER, AND FIRE HYDRANTS SHALL BE LOCATED SUCH THAT
THEY ARE WITHIN 150 FEET OF FIRE DEPARTMENT CONNECTION FOR THE BUILDING.
22. FIRE DEPARTMENT ACCESS (UFC 3-600-01 AND UFC 4-211-01)
ALL WEATHER GROUND ACCESS SHALL BE PROVIDED NO FARTHER THAN 33 FEET FROM TWO
COMPLETE SIDES OF BUILDINGS IN ACCORDANCE WITH UFC 3-600-01 SECTION 9-1 AND UFC
4-211-01 SECTION 3-3.1.11.
23. AUTOMATIC SPRINKLERS AND OTHER EXTINGUISHING EQUIPMENT (UFC 3-600-01, UFC 4-211-01, NFPA 409, AND NFPA 13)
THE ENTIRE BUILDING SHALL BE PROTECTED THROUGHOUT WITH A HYDRAULICALLY
CALCULATED AUTOMATIC SPRINKLER SYSTEM. DESIGN DENSITIES SHALL BE IN ACCORDANCE
WITH UFC 4-211-01, UFC 3-600-01, AND NFPA 13. WATER FOR FIRE PROTECTION WILL BE
PROVIDED BY NEWLY INSTALLED FIRE PUMPS AND FIRE WATER STORAGE TANKS. THE
HANGAR BAYS SHALL BE PROVIDED WITH BOTH AUTOMATIC SPRINKLERS AND A LOW LEVEL
HIGH EXPANSION FOAM SYSTEM IN ACCORDANCE WITH NFPA 11. THE FOAM GENERATORS
SHALL BE LOCATED TO PREVENT THE DISCHARGING FOAM FROM HITTING THE AIRCRAFT.
24. DRAFT CURTAINS (UFC 4-211-01, NFPA 409)
RECTANGULAR DRAFT CURTAINS SHALL BE INSTALLED AND EXTEND DOWN FROM THE ROOF
(OR CEILING) NOT LESS THAN ONE-EIGHTH OF THE DISTANCE FROM THE ROOF (OR CEILING) TO
THE FLOOR. WHEN ROOF STRUCTURAL SUPPORTS EXTEND BELOW THE ROOF OR CEILING,
DRAFT CURTAINS SHALL BE SUSPENDED TO THE LOWEST MEMBER OF THE STRUCTURAL
SUPPORTS, OR ONE EIGHTH THE DISTANCE FROM THE ROOF OR CEILING, WHICHEVER IS
GREATER.
25. FIRE ALARM (FA) AND MASS NOTIFICATION SYSTEMS (MNS) (UFC 3-600-01, UFC 4-021-01, AND NFPA 72)
THE BUILDING SHALL BE PROVIDED WITH A FIRE ALARM AND MASS NOTIFICATION SYSTEM
CONSISTING OF MANUAL PULL STATION, STROBES, SPEAKERS, SPRINKLER FLOW AND VALVE
TAMPER SUPERVISION, AND SMOKE DETECTORS WITHIN THE HVAC SYSTEMS AS REQUIRED
BY NFPA 90A. THE BUILDING IS NOT REQUIRED TO BE PROVIDED WITH SMOKE DETECTION
THROUGHOUT. THE FIRE ALARM AND MASS NOTIFICATION SYSTEM WILL TRANSMIT A SIGNAL
THROUGH A RADIO TRANSMITTER TO THE EXISTING BASE RECEIVING STATION.
26. ACCESSIBILITY REQUIREMENTS
THE HANGAR BUILDING SHALL BE ACCESSIBLE AND CONFORM TO ABA ACCESSIBILITY
STANDARD FOR DEPARTMENT OF DEFENSE FACILITIES AS ADOPTED BY THE DEPUTY
SECRETARY OF DEFENSE IN LIEU OF IBC CHAPTER 11 PER UFC 1-200-01.
27. ANTITERRORISM AND FORCE PROTECTION REQUIREMENTS (UFC 4-010-01 SECTION B-4.3)
AN EMERGENCY SHUTOFF SWITCH IN THE HVAC CONTROL SYSTEM CAPABLE OF IMMEDIATE
SHUT DOWN OF THE AIR DISTRIBUTION SYSTEM THROUGHOUT THE BUILDING.
SEPARATION OF MEANS OF EGRESS
EXITS SHALL BE PROVIDED SUCH THAT EXITS ARE AT LEAST 1/3 THE DIAGONAL DISTANCE OF
THE BUILDING APART PER NFPA 101, SECTION 7.5.1.3.3.
EXITS IN THE HANGAR SHALL ALSO BE PROVIDED SUCH THAT THE DOORS ARE SPACED AT A
MAXIMUM OF 150 FEET APART ALONG THE PERIMETER WALLS OF THE HANGAR BAY.
EXCEPTION IS THAT HANGAR DOORS THAT EXCEED 150 FT DO NOT REQUIRE A DOOR WITHIN
THE HANGAR DOOR. PERSONNEL DOORS SHALL BE PROVIDED WITHIN 20 FEET OF EACH END
OF THE HANGAR DOOR.
AREAS SERVING MECHANICAL EQUIPMENT AND VERTICAL FABRIC DOOR MOTORS SHALL BE
DEFINED AS EQUIPMENT PLATFORMS IN ACCORDANCE WITH IBC SECTION 505.3. THE
AGGREGATE AREA OF ALL EQUIPMENT PLATFORMS WITHIN A ROOM SHALL NOT BE GREATER
THAN TWO-THIRDS OF THE AREA OF THE ROOM IN WHICH THEY ARE LOCATED. SUCH
PLATFORMS AND THE WALKWAYS, STAIRS, ALTERNATING TREAD DEVICES, AND LADDERS
PROVIDING ACCESS TO AN EQUIPMENT PLATFORM SHALL NOT SERVE AS A PART OF THE
MEANS OF EGRESS FROM THE BUILDING. EQUIPMENT PLATFORMS SHALL NOT CONTRIBUTE
TO EITHER THE BUILDING AREA OR THE NUMBER OF STORIES.
15. OCCUPANT LOAD AND EGRESS CAPACITY CALCULATION
USE GROUP
OCCUPANT LOAD CALCULATIONS: NFPA 101 TABLE 7.3.1.2
TOTAL
OCCUPANT LOAD FACTOR
(SQUARE FEET / PERSON)
OCCUPANT
COUNT
BUSINESS 27
EXITS REQUIRED: 2 EXITS PROVIDED: 13 DIRECT EXITS AND 6 EXITS EACH
FROM ELECTRICAL ROOMS, TR / TER, FIRE PUMP AND
FOAM TANK ROOM, AND MECHANICAL ROOMS.
100 (GROSS)
STORAGE
52ANTICIPATED STAFF
AREA
(SQUARE FEET)
82986
15 (NET)ASSEMBLY
TER 1300 (NET)
MECHANICAL
ROOM
5500 (NET)
ELEC 2500 (NET) 600
1459 98
FIRE PUMP AND
FOAM TANK ROOM
500 (NET) 702 2
ELEC / TR 300 (GROSS) 200 1
HANGAR 500 (GROSS) 71811 144
LOCKERS
7300 (GROSS)
MECHANICAL
ROOM
2500 (NET) 900
E:2
EXIT NUMBER
MINIMUM CLEAR WIDTH
REQUIRED (IN)
E:1
EXIT CAPACITY CALCULATIONS: NFPA 101, 7.3.3.1
OCCUPANT CAPACITY
E:3
E:4
CLEAR WIDTH
PROVIDED (IN)
34 170
34 170
34 170
E:6
E:5
E:16
34 170
68 340
32 34 170
E:18 32 68 340
EXITS CAPACITY REQUIRED:
328 PERSONS
EXITS CAPACITY PROVIDED:
2380 PERSONS
EXTERIOR ELEC ROOM 107
EXITS CAPACITY REQUIRED:
2 PERSONS
EXITS CAPACITY PROVIDED:
340 PERSONS
EXTERIOR FIRE PUMP AND FOAM TANK ROOM 113
EXITS CAPACITY REQUIRED:
2 PERSONS
EXITS CAPACITY PROVIDED:
340 PERSONS
E:15 32 68 340
EXTERIOR MECHANICAL ROOM 106
EXITS CAPACITY REQUIRED:
2 PERSONS
EXITS CAPACITY PROVIDED:
340 PERSONS
E:14 32 34 170
EXTERIOR TER ROOM 100
EXITS CAPACITY REQUIRED:
1 PERSON
EXITS CAPACITY PROVIDED:
170 PERSONS
E:7
E:8
E:9
E:10
E:11
E:12
E:13
E:19
EXITS CAPACITY REQUIRED: EXITS CAPACITY PROVIDED:
EXTERIOR TR 110 AND ELECTRICAL ROOM 111
34 170
34 170
1 PERSON 170 PERSONS
E:17 32 68 340
EXTERIOR MECH ROOM 112
EXITS CAPACITY REQUIRED:
5 PERSONS
EXITS CAPACITY PROVIDED:
340 PERSONS
OCCUPANCY DEAD END (FT)
BUSINESS
EGRESS LIMITATIONS: NFPA 101, TABLE A.7.6
SPRINKLERED FACILITY
TRAVEL DISTANCE (FT)COMMON PATH (FT)
100 300
STORAGE
(ORDINARY
HAZARD)
100 100 400
ASSEMBLY 20 20 250
AIRCRAFT
HANGAR
50 100 400*
NOTES: THE HANGAR SHALL BE PROVIDED WITH EXITS LOCATED A MAXIMUM OF 150 FEET
APART AT THE EXTERIOR WALL OF THE HANGAR, EXCEPT ACROSS THE HANGAR DOOR OPENING.
WHERE THE HANGAR BAY DOOR OPENING EXCEEDS 110 FEET, PROVIDE THE FIRST EXIT OR EXIT
ACCESS WITHIN 20 FEET OF THE HANGAR BAY DOOR OPENING.
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
1 2 3 4 5
/1
/2
:4
:2
P M
G-100
L
IF
E S A F E T Y C O D E A N A L Y S
IS
K B
S D
A M
M C
Z
R T A D E C
D
E C
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
F E
C
TER
RESTROOM WOMEN'S
G003
RESTROOM MEN'S
G004
CORRIDOR
C002
MECHANICAL ROOM
ELEC
FUEL CELL TOOL ROOM
TOOL CRIB
HANGAR DOOR
MECH
TR
ELECTRICAL ROOM
FIRE PUMP AND FOAM
TANK ROOM
A
B
10.9 2 3 4
D
E
F
G
H
J
K
L
M
N
M.1
5 5.2 7 7.8 8.8 9 10 11 12 13
MENS LOCKER RM
G006
LOBBY
L001
1 HR
1 HR1 HR
1 HR
1 HR
1 HR
SP
1 HR
1 HR
SP
1 HR
SP
1 HR
SP
1 HR
SP
1 HR
SP
1 HR
1 HR
E-2
E-3
E-1
E-14
E-4
E-15
E-16
E-5
E-6
E-7
E-8
E-9
E-10 E-17
E-18
E-19
E-11
E-12
E-13
48'
90'
[1:15]
70'
VESTIBULE
V001
J.C.
G001
RESTROOM
G002
OPEN OFFICE
OFFICE
OFFICE
BREAKROOM
125'
E X
IT
S
P A
C
IN
G
E
X
IT
S P
A C
IN
G
E X
IT
S
P A
C
IN
G
EXIT SPACING = 86'
EXIT SPACING
= 25'
EXIT SPACING = 150'
E X
IT
S
P A
C
IN
G
3'
E X
IT
S
P A
C
IN
G
HALLWAY
C001
KB
HANGAR
EQUIP CLOSET
104A
HANGAR
1 HR
1 HR
860.50.40.20.00.1
C
D.1
D.6
M.7
M.8
KB
F.8
F.7
WOMENS LOCKER RM
G005
1 HOUR FIRE
BARRIER
1 HR
LEGEND
DESCRIPTION SYMBOL
SMOKE PARTITION SP
FIRE EXTINGUISHER
CABINET
FEC
OCCUPANCY
LOAD
EXIT NUMBER E-#
EXIT SIGN
TRAVEL
DISTANCE
COMMON PATH
OF TRAVEL
DEAD END
OCCUPANT LOAD
FACTOR
[X:Y]
PERSONS:SQUARE FOOT
KNOX BOX KB
GENERAL NOTES
1. REFER TO G-100 FOR LIFE SAFETY CODE
ANALYSIS.
2. EXIT SIGNS AND FIRE EXTINGUISHER LOCATIONS
ARE SHOWN FOR INFORMATION ONLY. REFER TO
ARCHITECTURAL AND ELECTRICAL DRAWINGS
FOR EXACT LOCATIONS AND DETAILS.
PNN
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y
C K
D B
Y
D A
T E
S
IZ
E E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A
IR
C R
A F
T M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B U
- 1 -R
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
1 2 3 4 5
/1
/2
:4
:3
P M
G-101
L
IF
E S A F E T Y F L O O R P L A N
K B
S D
A M
M C
Z
R T A D E C
D
E C
SCALE: 1/16" = 1'-0"
LIFE SAFETY - FLOOR PLAN
KEYNOTES
1 ROOMS WITH DIRECT ACCESS TO THE HANGAR
BAY SHALL BE ELECTRICALLY CLASSIFIED AS
CLASS 1, DIVISION 2 UP TO 18 INCHES ABOVE
FINISHED FLOOR.
SCALE: 1/16" = 1'-0"
0 8'-0" 16'-0" 32'-0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
| G-001 - COVER SHEET |
| G-002 - SHEET INDEX |
| G-100 - LIFE SAFETY - CODE ANALYSIS |
| G-101 - LIFE SAFETY - FLOOR PLAN |
File details come from the government source that posted it. Updated .