Appendix A-4 Dover DE Hazardous Materials Survey Final

View the file

Other files

File Type Posted
17R0032_Amendment_00007.pdf PDF
W912BU-17-R-0032_Specs-AM0005.pdf PDF
W912BU-17-R-0032_Dwgs-AM0005.pdf PDF
W912BU-17-R-0032_Specs-AM0004A.zip ZIP file
W912BU-17-R-0032_Specs-AM0004.zip ZIP file
W912BU-17-R-0032_Dwgs-AM0004.pdf PDF
17R0032_amendment3b.pdf PDF
W912BU-17-R-0032_Dwgs-AM0003.pdf PDF
W912BU-17-R-0032_Specs-AM0003.pdf PDF
Appendix_A-6_WelchDoverReferenceDwgPage25.pdf PDF
17-R-0032_Pre-Proposal_Site_Visit_Attendance_Roster.pdf PDF
W912BU-17-R-0032_Specs-AM0001.pdf PDF
RFI_Example.xls XLS spreadsheet
amendment_0001_SF30_(003).pdf PDF
RFP W912-BU-17-R-0032_Dwgs_Volume-3.pdf PDF
RFP W912-BU-17-R-0032_Dwgs_Volume-2.pdf PDF
RFP W912-BU-17-R-0032_Dwgs_Volume-1.pdf PDF
RFP_W912-BU-17-R-0032_Specs_Volume-2.pdf PDF
RFP_W912-BU-17-R-0032_Specs_Volume-1.pdf PDF
RFP_W912-BU-17-R-0032_Specs_Volume-3.pdf PDF
RFP_W912-BU-17-R-0032_Specs_Volume-4.pdf PDF
RFP_W912-BU-17-R-0032_Specs_Volume-5.pdf PDF
Appendix_A-5_price_breakout_schedule.pdf PDF
Appendix_A-6_WelchDoverReferenceDwgs.pdf PDF
Appendix_A-1_Geotech_Report.pdf PDF
Appendix_A-2_EPA_Technical_Guidance_for_Reducing_Lead_in_Drinking_Water_In_Schools.pdf PDF
Appendix_A-3_Soil_Gas_Assessment_Report.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Hazardous Materials Survey Welch Elementary/Dover Middle School Replacement

Dover Air Force Base Dover, Delaware November 1, 2016

Terracon Project No. J116P090

Prepared for:

Zyscovich Architects

Miami, Florida

Prepared by:

Terracon Consultants, Inc.

Manchester, NH mmcguinn Typewritten Text

APPENDIX A-4

mmcguinn Typewritten Text

HAZARDOUS MATERIALS SURVEY

mmcguinn Typewritten Text

RFP W912BU-17-R-0032

Responsive ■ Resourceful ■ Reliable i

TABLE OF CONTENTS

1.0 INTRODUCTION

1.1 Project Objective

1.2 Reliance

2.0 BUILDING DESCRIPTION

3.0 FIELD ACTIVITIES

3.1 Asbestos Survey

3.1.1 Visual Assessment

3.1.2 Physical Assessment

3.1.3 Sample Collection

3.1.4 Sample Analysis

3.2 Lead Paint Sampling

3.2.1 Visual Assessment

3.2.2 Sample Collection

3.2.3 Sample Analysis

3.3 Hazardous Materials Assessment

3.3.1 Visual Assessment

4.0 REGULATORY OVERVIEW

4.1 Asbestos

4.2 Lead

4.3 Hazardous Materials

5.0 FINDINGS and recommendations

5.1 Asbestos

5.2 Lead Sampling Summary

5.3 Hazardous Materials

6.0 LIMITATIONS/GENERAL COMMENTS

APPENDIX A ASBESTOS ANALYTICAL LABORATORY DATA

APPENDIX B LEAD ANALYTICAL LABORATORY DATA

APPENDIX C LICENSES AND CERTIFICATIONS

Responsive ■ Resourceful ■ Reliable 1

HAZARDOUS MATERIALS SURVEY

Welch Elementary/Dover Middle School Replacement Dover Air Force Base, Dover, Delaware

Terracon Project No. J116P090 November 1, 2016

1.0 INTRODUCTION

Terracon Consultants, Inc. (Terracon) conducted a pre-demolition Hazardous Materials Survey of Welch Elementary/Dover Middle School located at Dover Air Force Base, Dover, Delaware.

The survey was conducted on July 5 - 8 and October 12, 2016, by representatives from Terracon in general accordance with Terracon proposal J6155030, dated February 15, 2016. The interior and exterior building components were surveyed, and homogeneous areas of suspect asbestos-containing materials (ACM) were visually identified and documented. Although reasonable effort was made to survey accessible suspect materials, additional suspect but un-sampled materials could be located in walls, in voids, or in other concealed areas. Suspect ACM samples were collected in general accordance with the sampling protocols outlined in United States Environmental Protection Agency (USEPA) 40 Code of Federal Regulations (CFR) Part 763, Subpart E, known as the Asbestos Hazard Emergency Response Act (AHERA). Samples were delivered to an accredited laboratory for analysis by Polarized Light Microscopy (PLM).

1.1 Project Objective

We understand this Hazardous Materials Survey was requested due to the planned demolition of the on-site buildings to satisfy requirements of the USEPA 40 CFR Part 61, Subpart M, and National Emission Standards for Hazardous Air Pollutants (NESHAP).

1.2 Reliance

This report is for the exclusive use of Zyscovich Architects for the project being discussed.

Reliance by any other party on this report is prohibited without written authorization of Terracon and Zyscovich Architects. Reliance on this report by Zyscovich Architects and all authorized parties will be subject to the terms, conditions, and limitations stated in the proposal, this report, and Terracon’s Agreement for Services. The limitations of liability defined in Terracon’s Agreement for Services is the aggregate limit of Terracon’s liability to Zyscovich Architects.

Welch Elementary and Dover Middle School ■ Dover, DE November 1, 2016, 2016 ■ Terracon Project J116P090

Responsive ■ Resourceful ■ Reliable 2

2.0 BUILDING DESCRIPTION

The building is two stories with a glass and brick exterior, concrete block interior, and a metal roof used as an elementary and middle school. The structure is approximately 127,000 square feet.

3.0 FIELD ACTIVITIES

The survey was conducted by Terracon a Certified Asbestos Professional Services Firm. John Lynch, Leonard Giambrocco, and Vincent Giambrocco, AHERA accredited asbestos inspectors, conducted the survey. A copy of the licenses are attached as Appendix C. The survey was conducted in general accordance with the sample collection protocols established in USEPA 40 CFR Part 763, Subpart E, Section 763.86, AHERA. A summary of survey activities is provided below.

3.1 Asbestos Survey

The survey was conducted July 4 - 8, and October 12, 2016, by AHERA accredited asbestos inspectors. The survey was conducted in general accordance with the sample collection protocols established in USEPA 40 CFR Part 763 Subpart E 763.86, AHERA. A summary of survey activities is provided below.

3.1.1 Visual Assessment

Survey activities were initiated with visual observation of the interior and exterior of the building to identify homogeneous areas of suspect ACM. A homogeneous area (HA) consists of building materials that appear similar throughout in terms of color and texture with consideration given to the date of application. Interior assessment was conducted in visually accessible areas of the building proposed for renovation.

3.1.2 Physical Assessment

A physical assessment of each HA of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the USEPA as a material which can be crumbled, pulverized, or reduced to powder by hand pressure when dry. Friability was assessed by physically touching suspect materials.

3.1.3 Sample Collection

Based on results of the visual observation, bulk samples of suspect ACM were collected in general accordance with USEPA AHERA sampling protocols. Samples of suspect materials were collected from randomly selected locations in each homogeneous area. Bulk samples were

November 1, 2016, 2016 ■ Terracon Project J116P090

Responsive ■ Resourceful ■ Reliable 3 collected using wet methods as applicable to reduce the potential for fiber release. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.

The selection of sample locations and frequency of sampling were based on Terracon’s observations and the assumption that like materials in the same area are homogeneous in content.

Terracon collected two-hundred fifty-nine (259) samples from eighty-two (82) homogeneous areas of suspect ACM. A summary of suspect ACM samples collected during the survey is included as Appendix B.

3.1.4 Sample Analysis

Bulk samples were submitted under chain of custody to EMSL in Woburn, MA for analysis by polarized light microscopy with dispersion staining techniques per EPA 600/R-93/116. The percentage of asbestos, where applicable, was determined by microscopic visual estimation. Lab Name is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP) Accreditation No. 101147-0.

3.2 Lead Paint Sampling

3.2.1 Visual Assessment

Terracon visually assessed the interior and exterior of the existing building and perform Lead Paint (LP) sampling that consisted of collecting paint chip samples from various painted building components. Representative building components sampled included, walls, exterior façade, and exterior doors.

3.2.2 Sample Collection

The LP sampling began with the Terracon walking the building, observing painted surfaces, and selecting sample locations. After the sampling strategy was determined, Terracon collected thirty-three paint chip samples from select areas within building.

3.2.3 Sample Analysis

Paint chip samples were submitted under a chain of custody to EMSL Analytical, Inc. (EMSL) of Woburn, Massachusetts. Paint chip samples were analyzed by Flame Atomic Absorption method SW846-3050B/7000B. EMSL is an American Industrial Hygiene Association (AIHA) accredited laboratory (ELLAP, Lab Code 100194), to perform Flame Atomic Absorption analysis. The lead paint chip laboratory analytical report is provided in Appendix B.

November 1, 2016, 2016 ■ Terracon Project J116P090

Responsive ■ Resourceful ■ Reliable 4

3.3 Hazardous Materials Assessment

3.3.1 Visual Assessment

Terracon visually assessed the interior and exterior of the existing building for common hazardous materials including but not limited to Mercury-containing items and Polychlorinated-biphenyl (PCB) containing items.

4.0 REGULATORY OVERVIEW

4.1 Asbestos

The asbestos NESHAP (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. It also requires the identification and classification of existing building materials prior to demolition or renovation activities. Under NESHAP, asbestos-containing building materials are classified as either friable, Category I non-friable or Category II non-friable ACM. Friable materials are those that, when dry, may be crumbled, pulverized or reduced to powder by hand pressure. Category I non-friable ACM includes packings, gaskets, resilient floor coverings and asphalt roofing products containing more than 1% asbestos. Category II non-friable ACM are any materials other than Category I materials that contain more than 1% asbestos.

Friable ACM, Category I and Category II non-friable ACM which is in poor condition and has become friable or which will be subjected to drilling, sanding, grinding, cutting or abrading and which could be crushed or pulverized during anticipated renovation or demolition activities are considered regulated ACM (RACM).

In the state of Delaware, asbestos activities are regulated by the Delaware Office of Management and Budget, Division of Facilities Management, 16 Delaware Code, Chapter 78 (16 Del.C. Ch.78).

Delaware requires that any asbestos-related activity conducted be performed by an Certified Asbestos Professional Services Firm.

Asbestos abatement must be conducted by a Certified Asbestos Abatement Contractor Class “A” under the direct supervision of a Delaware Certified Asbestos Abatement Supervisor Class “A”. An asbestos abatement design must be prepared by a person accredited by the EPA under AHERA, 40 CFR 763. Third-party air monitoring must be conducted by a Delaware Certified Project Monitor employed by a Certified Asbestos Professional Services Firm.

The Occupational Safety and Health Administration (OSHA) Asbestos standard for construction (29 CFR 1926.1101) regulates workplace exposure to asbestos. The OSHA standard requires that employee exposure to airborne asbestos fibers be maintained below 0.1 asbestos fibers per cubic centimeter of air (0.1 f/cc). The OSHA standard classifies construction and maintenance activities, November 1, 2016, 2016 ■ Terracon Project J116P090

Responsive ■ Resourceful ■ Reliable 5 which could disturb ACM, and specifies work practices and precautions which employers must follow when engaging in each class of regulated work.

4.2 Lead

EPA and the State of Delaware has defined LBP as coatings that contain 1.0 milligram of lead per square centimeter (mg/cm2) or 0.5% by weight. LBP waste from renovation or demolition activities, such as debris, paint chips, dust, and sludges, that exhibit the toxicity characteristic must be managed and disposed as hazardous waste under the Resource Conservation and Recovery Act (RCRA), with the exception of whole-building demolition debris. Whole-building demolition debris is considered a non-hazardous waste with regard to lead. Therefore, no sampling/analysis of painted components for lead is required for disposal as non-hazardous waste. If it is not a whole-building demolition debris, a composite, representative sample of the demolition debris must be tested to determine if it is regulated as hazardous waste under 40 CFR 261 Identification and Listing of Hazardous Waste.

The OSHA Lead standard for construction (29 CFR 1926.62) requires that employee exposure to airborne lead must be maintained below the permissible exposure limit (PEL) of 50 micrograms of contaminant per cubic meter of air (mg/m3). OSHA does not define LCP; the requirements of the standard apply if any amount of lead is present in building materials. At a minimum, the contractor is required to provide respiratory protection appropriate to the task and conduct initial, representative exposure monitoring.

4.3 Hazardous Materials

Delaware solid waste regulations prohibit the disposal of PCB-containing ballasts in regular or solid waste landfills. These ballasts must be disposed of at an incineration/recycling facility.

Approximately 25% percent of ballasts manufactured after 1979 contain DEHP, a regulated substance under the USEPA Superfund regulations. DEHP-contaminated ballasts must be disposed of in the same manner as PCB-contaminated ballasts. Fluorescent light tubes, which contain mercury, are prohibited from disposal at in-state landfills due to their mercury content.

The preferred option is for the removal and recycling of the bulbs and ballasts at an approved recycling facility.

The USEPA has issued a number of fact sheets indicating that PCBs may be present in electrical equipment and building materials (e.g., caulk and other sealant materials) used in buildings constructed/renovated in the period from 1950 through approximately 1980. PCBs were a common additive to oils in electrical equipment, and caulk materials because of their water and chemical resistance, durability, and elasticity. PCBs were added as a plasticizer in caulking used to seal joints between masonry units and around windows. More specifically, PCBs were used in building materials such as paints, caulks, adhesives, mastics, sealants, and specialty coatings.

PCBs are known to leach into existing building substrate materials (existing brick and concrete)

November 1, 2016, 2016 ■ Terracon Project J116P090

Responsive ■ Resourceful ■ Reliable 6 adjacent to suspect PCB materials sampled. If suspect building materials sampled are less than 1 part per million (ppm), substrate sampling is not necessary. Disposal of substrate materials and electrical equipment containing PCBs at concentrations of 1 to 50 ppm will require disposal at an approved solid waste landfill; concentrations above 50 ppm will require disposal at a USEPA TSCA-approved landfill. Terracon recommends testing the building materials for PCBs prior to building demolition.

5.0 FINDINGS AND RECOMMENDATIONS

5.1 Asbestos

Asbestos containing materials were identified in the samples collected and analyzed.

ACM Summary – Welch Elementary School Sample

ID

Sample

Location Sample

Description Classification Asbestos

Quantities

04-MA-10

and 24-MA-

Girls and Boys Bathrooms, Custodial Closets, and bathrooms in Rooms 118, 119, 120, 121, 122, 123, 124, 208, 210, 211, 212, 213, 214, and 215

Ceramic Tile and Grout

Category II Non Friable

2% Chrysotile

3,000 SF

07-PI-19 Hallways Thermal System Pipe Insulation

RACM 3%

Chrysotile

1,500 LF

40-CA-121 Southeast Entrance Door

Door Caulk Category II Non Friable

3% Chrysotile

50 LF

40-CA-121 Door by Room 125 Door Caulk Category II Non Friable

3% Chrysotile

20 LF

N/A Boiler Room Flue Insulation* Category II Non Friable

Assumed Positive

150 SF

N/A Boiler Room Thermal System Pipe Insulation*

RACM Assumed Positive

165 LF

N/A Boiler Room Thermal System Pipe Insulation Fittings*

RACM Assumed Positive

N/A Boiler Room Boiler and Flue Gaskets*

RACM Assumed Positive

November 1, 2016, 2016 ■ Terracon Project J116P090

Responsive ■ Resourceful ■ Reliable 7

Sample

ID

Sample Location

Sample Description

Classification Asbestos

Quantities

N/A Boiler Room Pipe Flange Gaskets*

Category I Non Friable

Assumed Positive

N/A Throughout the School behind walls

Thermal System Pipe Insulation and Fittings*

RACM Assumed Positive

2,500 LF

*Materials unable to be sampled

Sample

ID

Sample Location

Sample Description

Classification Asbestos

Quantities

11M-MS-31 Room 179, 225, and

Transite Countertop

Category II Non Friable

15% Chrysotile

600 SF

04-MA-10

and 24-MA-

Large Bathrooms (4), Small Bathrooms (2), and Janitors Closets (3)

Ceramic Tile and Grout

Category II Non Friable

2% Chrysotile

3,000 SF

N/A Boiler Room Boiler Gaskets* Category I Non Friable

Assumed Positive

20 Each

N/A Boiler Room Pipe Flange Gaskets*

Category I Non Friable

Assumed Positive

N/A Cafeteria/Stage/Kitche n

Thermal System Pipe Insulation and Fittings*

RACM Assumed Positive

360 LF

N/A Cafeteria/Stage Stage Lighting Wire*

Category II Non Friable

Assumed Positive

80 LF

N/A Gymnasium Vibration Dampening Cloth*

Category II Non Friable

Assumed Positive

N/A Hallways Thermal System Pipe Insulation and Fittings*

RACM Assumed Positive

1,550 LF

N/A Gymnasium, Stage, Storage Rooms, Locker Rooms, Offices, and Locker Rooms

Thermal System Pipe Insulation and Fittings*

RACM Assumed

1,250 LF

November 1, 2016, 2016 ■ Terracon Project J116P090

Responsive ■ Resourceful ■ Reliable 8

*Materials unable to be sampled

ACM Summary – Welch Elementary/Dover Middle School

Based on the results of our visual survey and the results of the ACM testing, Terracon provides the following conclusions and recommendations:

n A licensed Asbestos Project Designer should prepare asbestos and hazardous materials abatement technical specifications for obtaining competitive bids for the removal of identified asbestos-containing materials that will be impacted by the proposed demolition activities.

n Prior to conducting demolition activities that will impact confirmed or assumed ACM at the Site, a Delaware-licensed asbestos abatement contractor must be retained to remove the ACM anticipated to be impacted by such activities.

5.2 Lead Sampling Summary

Welch Elementary School

Sample Location Description Method Lead Concentration

1 Exterior Blue Trim AAS 0.25 % 2 Exterior Blue Trim AAS 0.12 % 3 Exterior Blue Trim AAS 0.64 % 4 Interior Beige AAS 0.044 % 5 Interior Beige AAS 0.049 % 6 Interior Beige AAS 0.044 % 7 Interior Green AAS 0.21 % 8 Interior Green AAS 0.21 % 9 Interior Green AAS 0.13 % 10 Interior White AAS <0.019 % 11 Interior White AAS <0.010 %

N/A Room 128, Technology Lab and Hallway

Thermal System Pipe Insulation and Fittings*

RACM Assumed Positive

250 LF

N/A Room 128, Technology Lab and Hallway

Vibration Dampening Cloth*

Category II Non Friable

Assumed Positive

N/A Throughout the School

Chalkboard Mastic* Category II Non Friable

Assumed

3,700 SF

November 1, 2016, 2016 ■ Terracon Project J116P090

Responsive ■ Resourceful ■ Reliable 9

Sample Location Description Method Lead Concentration

12 Interior White AAS <0.018 % 13 Interior Green Trim AAS 0.030 % 14 Interior Green Trim AAS 0.030 % 15 Interior Green Trim AAS 0.042 % 16 Interior Red Door AAS 0.33 % 17 Interior Red Door AAS 0.41 % 18 Interior Red Door AAS 0.39 %

Dover Middle School

Sample Location Description Method Lead Concentration

A Interior Yellow AAS <0.014 % B Interior Yellow AAS <0.012 % C Interior Yellow AAS <0.015 % D Interior Blue AAS 0.25 % E Interior Blue AAS 0.25 % F Interior Blue AAS 0.26 % G Interior White AAS 0.040 % H Interior White AAS 0.031 % I Interior White AAS 0.039 % J Interior Light Blue AAS 0.081 % K Interior Light Blue AAS 0.074 % L Interior Light Blue AAS 0.046 % M Interior Light Purple AAS <0.019 % N Interior Light Purple AAS 0.021 % O Interior Light Purple AAS 0.014 %

Lead (ranging from <0.010-.64% of weight) was identified in representative paint collected for this project.

Based on the results of the lead paint sampling, Terracon provides the following conclusions and recommendations:

n Any disturbance of lead-containing paint would be subject to the OSHA Lead in Construction Standard, 29 CFR 1926.62. For proper disposal, it is the responsibility of FIRST’s contractor to perform the TCLP testing to appropriately determine the waste stream characterization.

November 1, 2016, 2016 ■ Terracon Project J116P090

Responsive ■ Resourceful ■ Reliable 10

Hazardous Materials

Terracon made visual observations for universal wastes within the building at the time of the survey. This allowed Terracon to obtain information on the potential presence of hazardous materials that require removal and disposal prior to demolition/demolition. Hazardous materials observed during the survey include miscellaneous equipment oils/lubricants, various solvent containers, mercury switches, emergency exit sign/ light batteries (lead-acid batteries), fluorescent tubes/ballasts, high intensity discharge lights, fire extinguishers, wall and ceiling-mounted heater units, air conditioning units, refrigeration units which may contain CFCs, and various containerized wastes. HVAC units were also observed at the Site. An area-by-area quantification estimate of hazardous materials is provided below for a listing of the locations and estimated quantities of the suspect universal wastes.

Welch Elementary School

Area Light Tubes Ballasts Exit

Signs Thermo stats

AC

Units Other

Roof 0 0 0 0 0 Two HVAC Units, 30

Pounds of R-22 Refrigerant each

Main Offices 14 0 0 0 0 2 Emergency Lights Principal’s

Office 6 0 0 0 0 N/A

Assistant Principals

Office 6 0 0 0 0 N/A

Records Room 6 0 0 0 0 N/A

Girls Bathroom

6 0 0 0 0 N/A

Janitors Closets –

Supply Room 2 0 0 0 0 Miscellaneous Cleaning

Chemicals

Boys Bathroom

6 0 0 0 0 N/A

Library – Room 113 60 0 0 2 2 2 Emergency Lights

Teachers’ Lounge – Room 112

45 0 0 1 1 2 Emergency Lights

Room 114 45 0 0 1 1 2 Emergency Lights Room 115 45 0 0 1 1 2 Emergency Lights

November 1, 2016, 2016 ■ Terracon Project J116P090

Responsive ■ Resourceful ■ Reliable 11

Area Light Tubes Ballasts Exit

Signs Thermo stats

AC

Units Other

Room 117 45 0 0 1 1 2 Emergency Lights Room 116 45 0 0 1 1 2 Emergency Lights

Hallway from Office to

Room 117 36 0 2 0 0 2 Emergency Lights

Stairwell 8 4 0 0 0 N/A Nurses Office –

Room 118 48 0 0 1 1 N/A

Room 119 50 0 0 1 1 2 Emergency Lights Room 121 50 0 0 1 1 2 Emergency Lights Room 120 50 0 0 1 1 2 Emergency Lights Room 122 50 0 0 1 1 2 Emergency Lights Room 123 50 0 0 1 1 2 Emergency Lights Storage Room 6 0 0 0 0 N/A

Room 124 50 0 0 1 1 2 Emergency Lights Stairwell 8 4 0 0 0 N/A

Hallway from 117 to 124 32 0 2 1 1 2 Emergency Lights

Hallway to Gymnasium 22 0 2 0 0 N/A

Gymnasium offices and storage rooms

13 0 0 0 0 N/A

Gym Storage 32 0 0 0 0 N/A Boys Room in Gymnasium

11 6 0 0 0 N/A

Stage 8 0 0 0 0 1 Fire Extinguisher Girls Room in Gymnasium

11 6 0 0 0 N/A

Gymnasium 160 0 6 1 0 N/A Short Hall to Room 126

11 0 2 0 0 2 Emergency Lights

Stairwell 8 4 0 0 0 N/A

November 1, 2016, 2016 ■ Terracon Project J116P090

Responsive ■ Resourceful ■ Reliable 12

Area Light Tubes Ballasts Exit

Signs Thermo stats

AC

Units Other

Hallway from 126 to 132

42 0 2 0 0 2 Emergency Lights

Room 126 45 0 0 1 1 2 Emergency Lights Room 128 45 0 0 1 1 2 Emergency Lights Room 125 45 0 0 1 1 2 Emergency Lights Room 127 45 0 0 1 1 2 Emergency Lights Room 130 45 0 0 1 1 2 Emergency Lights Room 132 45 0 0 1 1 2 Emergency Lights Room 129 45 0 0 1 1 2 Emergency Lights Room 131 45 0 0 1 1 2 Emergency Lights

Lounge 9 0 0 1 0 N/A Boys

Bathroom 8 4 0 1 0 N/A

Janitors Closet

2 1 0 0 0 N/A

Girls Bathroom 8 4 0 1 0 N/A

Small Boiler Room 10 0 0 0 0

1 Water Cooler Compressor, 1 Dryer, 2 Quarts of Oil, 6 Cans

Solvent, 1 Fire Extinguisher, and 1 Wall

Transformer

Storage by Boiler Room 4 0 0 0 1

6 Cans of Spray Paint, 2 Quarts of Oil, and Ten

Gallons of Paint Book Room 36 0 0 1 0 N/A Room 122 45 0 0 1 1 2 Emergency Lights Room 124 45 0 0 1 1 2 Emergency Lights Elevator

Hallway – 2nd

Floor 47 0 2 0 0 2 Emergency Lights

Hallway 201 to 209 38 0 2 0 0 2 Emergency Lights

Room 206 45 0 0 1 1 2 Emergency Lights Room 209 45 0 0 1 1 2 Emergency Lights Room 207 45 0 0 1 1 2 Emergency Lights

November 1, 2016, 2016 ■ Terracon Project J116P090

Responsive ■ Resourceful ■ Reliable 13

Area Light Tubes Ballasts Exit

Signs Thermo stats

AC

Units Other

Room 204 45 0 0 1 1 2 Emergency Lights Room 202 45 0 0 1 1 2 Emergency Lights Room 205 45 0 0 1 1 2 Emergency Lights Room 203 45 0 0 1 1 2 Emergency Lights

Boys Bathroom

8 0 0 0 0 N/A

Custodial Closet

2 0 0 0 0 N/A

Girls Bathroom 8 0 0 0 0 N/A

Room 201 18 0 0 1 1 2 Emergency Lights Room 200 9 0 0 1 1 2 Emergency Lights

Hallway from 208 to 214 30 0 2 0 0 2 Emergency Lights

Room 208 50 0 0 1 1 2 Emergency Lights Room 211 50 0 0 1 1 2 Emergency Lights Room 213 50 0 0 1 1 2 Emergency Lights Room 210 50 0 0 1 1 2 Emergency Lights Room 212 50 0 0 1 1 2 Emergency Lights Room 215 50 0 0 1 1 2 Emergency Lights Room 214 50 0 0 1 1 2 Emergency Lights

Total 2,420 24 14 46 43 N/A

Dover Middle School

Area Light Tubes Ballasts Exit

Signs Thermo stats

AC

Units Other

Hallway from 123 to

Student Services

40 0 0 0 0 2 Emergency Lights

Room 123 40 0 0 1 1 2 Emergency Lights Library –

Room 127 99 4 0 3 3 2 Emergency Lights and

1 Refrigerator Computer

Lab – Room

45 0 0 1 1 2 Emergency Lights

Stairwell 6 0 0 1 0 0

November 1, 2016, 2016 ■ Terracon Project J116P090

Responsive ■ Resourceful ■ Reliable 14

Area Light Tubes Ballasts Exit

Signs Thermo stats

AC

Units Other

Hallway – Exits to

Room 128 24 0 2 1 0 2 Emergency Lights

Room 128 72 0 0 2 3 2 Emergency Lights Stairwell 6 0 0 1 0 0

Hallway from Room 130 to

Cafeteria Storage

24 0 2 0 0 2 Emergency Lights and 1 Fire Extinguisher

Room 130 36 0 0 1 1 2 Emergency Lights Room 131 36 0 0 1 1 2 Emergency Lights Room 132 36 0 0 1 1 2 Emergency Lights Room 133 36 0 0 1 1 2 Emergency Lights Room 134 36 0 0 1 1 2 Emergency Lights Room 135 36 0 0 1 1 2 Emergency Lights

Hallway from Room 135 to

Stage 33 0 0 1 0 2 Emergency Lights and

1 Fire Extinguisher

Stairwell 6 0 0 1 0 0 Boys

Bathroom 8 0 0 0 0 0

Girls Bathroom

8 0 0 1 0 0

Custodial Closet 2 0 0 0 0 0

Boiler Room 6 0 0 0 0

1 Compressor, 1 Condenser, 1 Switchgear, 2 Water Hot Water Tanks, 3 Oil Lines, and 1

Fire Extinguisher

Kitchen 48 48 0 1 2

2 Walk In Coolers, 4 Double Freezers, 1 Single Freezer, 2

Refrigerators, 4 Ovens, and 2 Fire Extinguishers

Cafeteria 216 0 0 2 0 0

Stage 4 1 0 0 0 1 Transformer and 96 Incandescent Lights

Room 177 60 0 0 1 1 2 Emergency Lights

November 1, 2016, 2016 ■ Terracon Project J116P090

Responsive ■ Resourceful ■ Reliable 15

Area Light Tubes Ballasts Exit

Signs Thermo stats

AC

Units Other

Room 166 9 0 0 0 0 2 Emergency Lights

Room 179 64 2 0 2 1 2 Emergency Lights and 1 Refrigerator

Room 180 45 0 0 1 1 2 Emergency Lights

Room 180A 18 0 0 1 1 2 Emergency Lights and 1 Refrigerator

Room 181A 27 0 0 1 2 2 Emergency Lights Home

Economics – Room 181

50 5 0 1 1 2 Emergency Lights, 1 Refrigerator, 5 Ovens, One Dryer, and 1 Washer Storage 6 0 0 0 0 0

Small Hall with closet and sink

6 0 0 0 0 2 Emergency Lights and 1 Refrigerator

Teachers’ Lounge 15 0 0 1 1 1 Soda Machine

Conference Room

12 0 0 1 1 0

Principal’s Office

9 0 0 1 0 0

School Store 3 0 0 0 0 0 Assistant Principals

Office 6 0 0 1 1 0

Main Office 18 0 0 1 0 0 Hallway by Gymnasium

42 0 0 1 0 2 Emergency Lights

Stairwell 6 0 0 1 0 0

Gymnasium 0 0 0 0 0 32 Halogen Lights and 1

Water Fountain Boys Locker

Room 12 6 0 1 0 Miscellaneous Cleaning

Chemicals Girls Locker

Room 12 6 0 1 0 0

Stage 12 0 0 1 0 0 Electrical

Closet 12 0 0 1 0 Switchgear

Room 237 27 0 0 1 1 2 Emergency Lights

November 1, 2016, 2016 ■ Terracon Project J116P090

Responsive ■ Resourceful ■ Reliable 16

Area Light Tubes Ballasts Exit

Signs Thermo stats

AC

Units Other

Janitors Closet

2 0 0 0 0 0 Miscellaneous Cleaning Chemicals

237A Storage

4 2 0 1 0 2 Emergency Lights

Girls Bathroom –

2nd Floor 8 0 0 1 0 0

Boys Bathroom –

2nd Floor 8 0 0 1 0 0

Hallway 6 0 0 0 0 2 Emergency Lights and 1 Water Fountain

Room 231 36 0 0 2 1 2 Emergency Lights Room 232 36 0 0 1 1 2 Emergency Lights

Rear Hallway 24 0 0 0 0 2 Emergency Lights Room 229 36 0 0 1 1 2 Emergency Lights Room 230 36 0 0 1 1 2 Emergency Lights Room 227 36 0 0 1 1 2 Emergency Lights Room 228 36 0 0 1 1 2 Emergency Lights Room 225 36 0 0 1 1 2 Emergency Lights

Interior Office 12 0 0 0 0 0 Room 226 48 0 0 1 1 2 Emergency Lights Hallway 24 0 0 1 0 2 Emergency Lights Total 1,690 62 4 54 36 N/A

Based on the results of our visual survey of the OHMs, Terracon provides the following conclusions and recommendations:

n Prior to conducting demolition activities that will impact the identified materials above at the Site, a Delaware-licensed contractor must be retained to remove the identified electrical and mechanical equipment materials above anticipated to be impacted by such activities.

No other environmental sampling was conducted during this survey.

November 1, 2016, 2016 ■ Terracon Project J116P090

Responsive ■ Resourceful ■ Reliable 17

6.0 LIMITATIONS/GENERAL COMMENTS

Terracon did not perform sampling requiring demolition or destructive activities such as knocking holes in walls, dismantling of equipment, or removal of protective coverings. Reasonable efforts to access suspect materials within known areas of restricted access (e.g., crawl spaces) were made; however, confined spaces or areas which may pose a health or safety risk to Terracon personnel were not sampled. Sampling did not include suspect materials which could not be safely reached with available ladders/man-lifts. Additionally, roofing materials were not sampled during this survey.

This asbestos survey was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions, and recommendations expressed in this report are based on conditions observed during our survey of the building. The information contained in this report is relevant to the date on which this survey was performed, and should not be relied upon to represent conditions at a later date. This report has been prepared on behalf of and exclusively for use by Zyscovich Architects for specific application to their project as discussed. This report is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories, or other third parties supplying information which may have been used in the preparation of this report. No warranty, express or implied is made.

APPENDIX A

ASBESTOS ANALYTICAL LABORATORY DATA

EMSL Analytical, Inc.

7 Constitution Way, Suite 107 Woburn, MA 01801

Tel/Fax: (781) 933-8411 / (781) 933-8412 http://www.EMSL.com / bostonlab@emsl.com

131603165EMSL Order:

Customer ID: JAWO50

Customer PO: J6167045

Project ID:

Attention: Phone:John Lynch (603) 647-9700

Fax:Terracon Consultants, Inc. (603) 647-4432

Received Date:77 Sundial Avenue 07/13/2016 9:20 AM

Analysis Date:Suite 401-W 07/19/2016 - 07/20/2016

Collected Date:Manchester, NH 03103

Project: J6167045

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

01-FC-01

131603165-0001

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Main Office Hall -

Floor Tile 1x1

01-FC-02

131603165-0002

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Main Office Hall -

Floor Tile 1x1

01-FC-03

131603165-0003

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Main Office Hall -

Floor Tile 1x1

02-FC-04

131603165-0004

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Main Office Hall -

Floor Mastic

02-FC-05

131603165-0005

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Main Office Hall -

Floor Mastic

02-FC-06

131603165-0006

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Main Office Hall -

Floor Mastic

03-MG-07

131603165-0007

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Main Office Hall -

Cove Base Mastic

03-MG-08

131603165-0008

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Main Office Hall -

Cove Base Mastic

03-MG-09

131603165-0009

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Main Office Hall -

Cove Base Mastic

04-MA-10

131603165-0010

2% ChrysotileNon-fibrous (Other)98%Gray

Non-Fibrous

Homogeneous

Girls Lav - Ceramic

Tile Grout

04-MA-11

131603165-0011

Positive Stop (Not Analyzed)Girls Lav - Ceramic

Tile Grout

04-MA-12

131603165-0012

Positive Stop (Not Analyzed)Girls Lav - Ceramic

Tile Grout

05-MA-13

131603165-0013

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Girls Lav - Caulk

Around Door

05-MA-14

131603165-0014

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Girls Lav - Caulk

Around Door

05-MA-15

131603165-0015

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Girls Lav - Caulk

Around Door

06-PI-16

131603165-0016

None DetectedNon-fibrous (Other)85%Glass15%White

Fibrous

Homogeneous

Main Hall Classrooms

Throughout - Pipe

Insulation

Initial Report From: 07/20/2016 13:48:32

Page 1 of 9ASB_PLM_0008 - 1.71 Printed: 7/20/2016 1:48 PM

Tel/Fax: (781) 933-8411 / (781) 933-8412 http://www.EMSL.com / bostonlab@emsl.com

131603165EMSL Order:

Customer ID: JAWO50

Customer PO: J6167045

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

06-PI-17

131603165-0017

None DetectedNon-fibrous (Other)85%Glass15%White

Fibrous

Homogeneous

Main Hall Classrooms

Throughout - Pipe

Insulation

06-PI-18

131603165-0018

None DetectedNon-fibrous (Other)85%Glass15%White

Fibrous

Homogeneous

Main Hall Classrooms

Throughout - Pipe

Insulation

07-PI-19

131603165-0019

3% ChrysotileNon-fibrous (Other)87%Min. Wool10%White

Fibrous

Homogeneous

Main Hall Classrooms

- Pipe Insulation

07-PI-20

131603165-0020

Positive Stop (Not Analyzed)Main Hall Classrooms

- Pipe Insulation

07-PI-21

131603165-0021

Positive Stop (Not Analyzed)Main Hall Classrooms

- Pipe Insulation

08-MA-22

131603165-0022

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Girls Lav/Boys - Tile

Grout - Floor

08-MA-23

131603165-0023

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Girls Lav/Boys - Tile

Grout - Floor

08-MA-24

131603165-0024

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Girls Lav/Boys - Tile

Grout - Floor

09-PL-25

131603165-0025

None DetectedNon-fibrous (Other)98%Hair2%Gray/White

Non-Fibrous

Homogeneous

Lav Main Hall -

Plaster Ceiling

09-PL-26

131603165-0026

None DetectedNon-fibrous (Other)98%Hair2%Gray/White

Non-Fibrous

Homogeneous

Lav Main Hall -

Plaster Ceiling

09-PL-27

131603165-0027

None DetectedNon-fibrous (Other)98%Hair2%Gray/White

Non-Fibrous

Homogeneous

Lav Main Hall -

Plaster Ceiling

10-MA-28

131603165-0028

None DetectedNon-fibrous (Other)100%Beige

Non-Fibrous

Homogeneous

Main Office - Cove

Base Mastic

10-MA-29

131603165-0029

None DetectedNon-fibrous (Other)100%Brown/Beige

Non-Fibrous

Homogeneous

Main Office - Cove

Base Mastic

10-MA-30

131603165-0030

None DetectedNon-fibrous (Other)100%Beige

Non-Fibrous

Homogeneous

Main Office - Cove

Base Mastic

11-MA-31

131603165-0031

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Main Office - Carpet

Glue

11-MA-32

131603165-0032

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Main Office - Carpet

Glue

11-MA-33

131603165-0033

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Main Office - Carpet

Glue

12-CA-34

131603165-0034

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Library - Around A/C -

Window Caulk

12-CA-35

131603165-0035

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Library - Around A/C -

Window Caulk

Page 2 of 9ASB_PLM_0008 - 1.71 Printed: 7/20/2016 1:48 PM

Tel/Fax: (781) 933-8411 / (781) 933-8412 http://www.EMSL.com / bostonlab@emsl.com

131603165EMSL Order:

Customer ID: JAWO50

Customer PO: J6167045

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

12-CA-36

131603165-0036

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Library - Around A/C -

Window Caulk

13-MA-37

131603165-0037

None DetectedNon-fibrous (Other)100%Green

Non-Fibrous

Homogeneous

Library - Carpet Glue

13-MA-38

131603165-0038

None DetectedNon-fibrous (Other)100%Green

Non-Fibrous

Homogeneous

Library - Carpet Glue

13-MA-39

131603165-0039

None DetectedNon-fibrous (Other)100%Green

Non-Fibrous

Homogeneous

Library - Carpet Glue

14-CT-40

131603165-0040

None DetectedNon-fibrous (Other)20%Cellulose

Min. Wool

40%

40%

Gray/White

Fibrous

Homogeneous

Library - Ceiling Tile

2x4

14-CT-41

131603165-0041

None DetectedNon-fibrous (Other)20%Cellulose

Min. Wool

40%

40%

Gray/White

Fibrous

Homogeneous

Library - Ceiling Tile

2x4

14-CT-42

131603165-0042

None DetectedNon-fibrous (Other)20%Cellulose

Min. Wool

40%

40%

Gray/White

Fibrous

Homogeneous

Library - Ceiling Tile

2x4

15-CT-43

131603165-0043

None DetectedNon-fibrous (Other)20%Cellulose

Min. Wool

40%

40%

Gray

Fibrous

Homogeneous

Library - Ceiling Tile

1x1

15-CT-44

131603165-0044

None DetectedNon-fibrous (Other)20%Cellulose

Min. Wool

40%

40%

Gray

Fibrous

Homogeneous

Library - Ceiling Tile

1x1

15-CT-45

131603165-0045

None DetectedNon-fibrous (Other)20%Cellulose

Min. Wool

40%

40%

Gray/White

Fibrous

Homogeneous

Library - Ceiling Tile

1x1

16-SI-46

131603165-0046

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Teachers Lounge -

Sink Coating

16-SI-47

131603165-0047

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Teachers Lounge -

Sink Coating

16-SI-48

131603165-0048

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Teachers Lounge -

Sink Coating

17-FT-49-Floor Tile

131603165-0049

None DetectedNon-fibrous (Other)100%Beige

Non-Fibrous

Homogeneous

Rm 114 - 1x1 Floor

Tile and Mastic

17-FT-49-Mastic

131603165-0049A

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Rm 114 - 1x1 Floor

Tile and Mastic

17-FT-50-Floor Tile

131603165-0050

None DetectedNon-fibrous (Other)100%Beige

Non-Fibrous

Homogeneous

Rm 114 - 1x1 Floor

Tile and Mastic

17-FT-50-Mastic

131603165-0050A

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Rm 114 - 1x1 Floor

Tile and Mastic

17-FT-51-Floor Tile

131603165-0051

None DetectedNon-fibrous (Other)100%Beige

Non-Fibrous

Homogeneous

Rm 114 - 1x1 Floor

Tile and Mastic

17-FT-51-Mastic

131603165-0051A

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Rm 114 - 1x1 Floor

Tile and Mastic

Page 3 of 9ASB_PLM_0008 - 1.71 Printed: 7/20/2016 1:48 PM

Tel/Fax: (781) 933-8411 / (781) 933-8412 http://www.EMSL.com / bostonlab@emsl.com

131603165EMSL Order:

Customer ID: JAWO50

Customer PO: J6167045

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

18-MA-52

131603165-0052

None DetectedNon-fibrous (Other)100%Brown/Black

Non-Fibrous

Homogeneous

Rm 114 - Cove Base

18-MA-53

131603165-0053

None DetectedNon-fibrous (Other)100%Brown/Black

Non-Fibrous

Homogeneous

Rm 114 - Cove Base

18-MA-54

131603165-0054

None DetectedNon-fibrous (Other)100%Brown/Black

Non-Fibrous

Homogeneous

Rm 114 - Cove Base

19-SI-55

131603165-0055

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Rm 114 - Sink

Undercoat

19-SI-56

131603165-0056

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Rm 114 - Sink

Undercoat

19-SI-57

131603165-0057

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Rm 114 - Sink

Undercoat

20-MA-58

131603165-0058

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Stair Tread Glue

20-MA-59

131603165-0059

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Stair Tread Glue

20-MA-60

131603165-0060

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Stair Tread Glue

21-FT-61

131603165-0061

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Hall Between 117-119

- Floor - 1st Layer

21-FT-62

131603165-0062

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Hall Between 117-119

- Floor - 1st Layer

21-FT-63

131603165-0063

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Hall Between 117-119

- Floor - 1st Layer

22-FT-64

131603165-0064

None DetectedNon-fibrous (Other)85%Cellulose15%Gray

Fibrous

Homogeneous

Between 117-119 -

Floor - 2nd Layer

22-FT-65

131603165-0065

None DetectedNon-fibrous (Other)85%Cellulose15%Gray

Fibrous

Homogeneous

Between 117-119 -

Floor - 2nd Layer

22-FT-66

131603165-0066

None DetectedNon-fibrous (Other)85%Cellulose15%Gray

Fibrous

Homogeneous

Between 117-119 -

Floor - 2nd Layer

23-FT-67

131603165-0067

None DetectedNon-fibrous (Other)100%Green

Non-Fibrous

Homogeneous

Between 117-119 -

Floor - 2nd Layer

23-FT-68

131603165-0068

None DetectedNon-fibrous (Other)100%Green

Non-Fibrous

Homogeneous

Between 117-119 -

Floor - 2nd Layer

23-FT-69

131603165-0069

None DetectedNon-fibrous (Other)100%Green

Non-Fibrous

Homogeneous

Between 117-119 -

Floor - 2nd Layer

24-MA-70

131603165-0070

2% ChrysotileNon-fibrous (Other)98%Gray

Non-Fibrous

Homogeneous

From Rm 118 Lav -

Mortar - Ceramic Tile

Page 4 of 9ASB_PLM_0008 - 1.71 Printed: 7/20/2016 1:48 PM

Tel/Fax: (781) 933-8411 / (781) 933-8412 http://www.EMSL.com / bostonlab@emsl.com

131603165EMSL Order:

Customer ID: JAWO50

Customer PO: J6167045

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

24-MA-71

131603165-0071

Positive Stop (Not Analyzed)From Rm 118 Lav -

Mortar - Ceramic Tile

24-MA-72

131603165-0072

Positive Stop (Not Analyzed)From Rm 118 Lav -

Mortar - Ceramic Tile

25-MA-73

131603165-0073

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Gym Lav - Tile Grout

25-MA-74

131603165-0074

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Gym Lav - Tile Grout

25-MA-75

131603165-0075

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Gym Lav - Tile Grout

25-FT-76-Floor Tile

131603165-0076

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Rm 214 - Vinyl Floor

& Mastic

25-FT-76-Mastic

131603165-0076A

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Rm 214 - Vinyl Floor

& Mastic

25-FT-77-Floor Tile

131603165-0077

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Rm 214 - Vinyl Floor

& Mastic

25-FT-77-Mastic

131603165-0077A

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Rm 214 - Vinyl Floor

& Mastic

25-FT-78-Floor Tile

131603165-0078

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Rm 214 - Vinyl Floor

& Mastic

25-FT-78-Mastic

131603165-0078A

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Rm 214 - Vinyl Floor

& Mastic

26-FT-79-Floor Tile

131603165-0079

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

1st Floor Hall Next to

Elevator - Floor Tile &

Mastic

26-FT-79-Mastic

131603165-0079A

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

1st Floor Hall Next to

Elevator - Floor Tile &

Mastic

26-FT-80-Floor Tile

131603165-0080

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

1st Floor Hall Next to

Elevator - Floor Tile &

Mastic

26-FT-80-Mastic

131603165-0080A

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

1st Floor Hall Next to

Elevator - Floor Tile &

Mastic

26-FT-81-Floor Tile

131603165-0081

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

1st Floor Hall Next to

Elevator - Floor Tile &

Mastic

26-FT-81-Mastic

131603165-0081A

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

1st Floor Hall Next to

Elevator - Floor Tile &

Mastic

27-BI-82

131603165-0082

None DetectedNon-fibrous (Other)55%Cellulose

Min. Wool

Glass

10%

25%

10%

Gray

Fibrous

Homogeneous

Boiler Insulation

Breach

27-BI-83

131603165-0083

None DetectedNon-fibrous (Other)55%Cellulose

Min. Wool

Glass

10%

25%

10%

Gray

Fibrous

Homogeneous

Boiler Insulation

Breach

Page 5 of 9ASB_PLM_0008 - 1.71 Printed: 7/20/2016 1:48 PM

Tel/Fax: (781) 933-8411 / (781) 933-8412 http://www.EMSL.com / bostonlab@emsl.com

131603165EMSL Order:

Customer ID: JAWO50

Customer PO: J6167045

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

27-BI-84

131603165-0084

None DetectedNon-fibrous (Other)65%Cellulose

Min. Wool

10%

25%

Gray

Fibrous

Homogeneous

Boiler Insulation

Breach

28-HP-85

131603165-0085

None DetectedNon-fibrous (Other)100%Gray/White

Non-Fibrous

Homogeneous

Boiler Room - Ceiling

Plaster

28-HP-86

131603165-0086

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Boiler Room - Ceiling

Plaster

28-HP-87

131603165-0087

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Boiler Room - Ceiling

Plaster

29-CA-88

131603165-0088

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Boiler Room at

Corner of Building

Southeast Side -

Window Glaze

29-CA-89

131603165-0089

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Boiler Room at

Corner of Building

Southeast Side -

Window Glaze

29-CA-90

131603165-0090

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Boiler Room at

Corner of Building

Southeast Side -

Window Glaze

30-CA-91

131603165-0091

None DetectedNon-fibrous (Other)100%Blue

Non-Fibrous

Homogeneous

Southeast Side -

Window Glaze - Teal

30-CA-92

131603165-0092

None DetectedNon-fibrous (Other)100%Blue

Non-Fibrous

Homogeneous

Southeast Side -

Window Glaze - Teal

30-CA-93

131603165-0093

None DetectedNon-fibrous (Other)100%Blue

Non-Fibrous

Homogeneous

Southeast Side -

Window Glaze - Teal

31-CA-94

131603165-0094

None DetectedNon-fibrous (Other)92%Cellulose8%Black

Non-Fibrous

Homogeneous

Southeast Side -

Black Foundation

Caulk

31-CA-95

131603165-0095

None DetectedNon-fibrous (Other)92%Cellulose8%Black

Non-Fibrous

Homogeneous

Southeast Side -

Black Foundation

Caulk

31-CA-96

131603165-0096

None DetectedNon-fibrous (Other)92%Cellulose8%Black

Non-Fibrous

Homogeneous

Southeast Side -

Black Foundation

Caulk

32-CA-97

131603165-0097

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Southeast Side -

White Caulk

32-CA-98

131603165-0098

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Southeast Side -

White Caulk

32-CA-99

131603165-0099

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Southeast Side -

White Caulk

33-RF-100

131603165-0100

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Roof Over Rm 126 -

Rubber

33-RF-101

131603165-0101

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Roof Over Rm 126 -

Rubber

Page 6 of 9ASB_PLM_0008 - 1.71 Printed: 7/20/2016 1:48 PM

Tel/Fax: (781) 933-8411 / (781) 933-8412 http://www.EMSL.com / bostonlab@emsl.com

131603165EMSL Order:

Customer ID: JAWO50

Customer PO: J6167045

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

33-RF-102

131603165-0102

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Roof Over Rm 126 -

Rubber

34-RF-103

131603165-0103

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Roof Over Rm 126 -

Black Pitch Under

Foam

34-RF-104

131603165-0104

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Roof Over Rm 126 -

Black Pitch Under

Foam

34-RF-105

131603165-0105

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Roof Over Rm 126 -

Black Pitch Under

Foam

35-RF-106

131603165-0106

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Roof Over Rm 126 -

White Material

35-RF-107

131603165-0107

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Roof Over Rm 126 -

White Material

35-RF-108

131603165-0108

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Roof Over Rm 126 -

White Material

36-RF-109

131603165-0109

None DetectedNon-fibrous (Other)100%Clear

Non-Fibrous

Homogeneous

Roof Over Rm 126 -

Mastic/Caulk

36-RF-110

131603165-0110

None DetectedNon-fibrous (Other)100%Clear

Non-Fibrous

Homogeneous

Roof Over Rm 126 -

Mastic/Caulk

36-RF-111

131603165-0111

None DetectedNon-fibrous (Other)100%Clear

Non-Fibrous

Homogeneous

Roof Over Rm 126 -

Mastic/Caulk

37-RF-112

131603165-0112

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Roof Over Rm 126 -

Black Window Caulk

37-RF-113

131603165-0113

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Roof Over Rm 126 -

Black Window Caulk

37-RF-114

131603165-0114

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Roof Over Rm 126 -

Black Window Caulk

38-RF-115

131603165-0115

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Over Rm 126 - Grey

Window Caulk -

Outside

38-RF-116

131603165-0116

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Over Rm 126 - Grey

Window Caulk -

Outside

38-RF-117

131603165-0117

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Over Rm 126 - Grey

Window Caulk -

Outside

39-CA-118

131603165-0118

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Southeast Entrance -

Door Caulk

39-CA-119

131603165-0119

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Southeast Entrance -

Door Caulk

39-CA-120

131603165-0120

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Southeast Entrance -

Door Caulk

Page 7 of 9ASB_PLM_0008 - 1.71 Printed: 7/20/2016 1:48 PM

Tel/Fax: (781) 933-8411 / (781) 933-8412 http://www.EMSL.com / bostonlab@emsl.com

131603165EMSL Order:

Customer ID: JAWO50

Customer PO: J6167045

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

40-CA-121

131603165-0121

3% ChrysotileNon-fibrous (Other)97%Gray

Non-Fibrous

Homogeneous

Southeast Entrance -

Door Caulk

40-CA-122

131603165-0122

Positive Stop (Not Analyzed)Southeast Entrance -

Door Caulk

40-CA-123

131603165-0123

Positive Stop (Not Analyzed)Southeast Entrance -

Door Caulk

40-MS-124

131603165-0124

None DetectedNon-fibrous (Other)2%Cellulose98%Brown

Fibrous

Homogeneous

Library - Door Core

40-MS-125

131603165-0125

None DetectedNon-fibrous (Other)2%Cellulose98%Brown

Fibrous

Homogeneous

Library - Door Core

40-MS-126

131603165-0126

None DetectedNon-fibrous (Other)2%Cellulose98%Brown

Non-Fibrous

Homogeneous

Library - Door Core

41-CA-127

131603165-0127

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Outside Windows

Inside Courtyard -

Window Caulk

41-CA-128

131603165-0128

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Outside Windows

Inside Courtyard -

Window Caulk

41-CA-129

131603165-0129

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Outside Windows

Inside Courtyard -

Window Caulk

42-CA-130

131603165-0130

None DetectedNon-fibrous (Other)100%Beige

Non-Fibrous

Homogeneous

Front Entrance -

Caulk Door

42-CA-131

131603165-0131

None DetectedNon-fibrous (Other)100%Beige

Non-Fibrous

Homogeneous

Front Entrance -

Caulk Door

42-CA-132

131603165-0132

None DetectedNon-fibrous (Other)100%Beige

Non-Fibrous

Homogeneous

Front Entrance -

Caulk Door

43-CA-133

131603165-0133

None DetectedNon-fibrous (Other)100%Gray/White

Non-Fibrous

Homogeneous

Between Window &

Brick Front Side -

Caulk

43-CA-134

131603165-0134

None DetectedNon-fibrous (Other)100%Gray/White

Non-Fibrous

Homogeneous

Between Window &

Brick Front Side -

Caulk

43-CA-135

131603165-0135

None DetectedNon-fibrous (Other)100%Gray/White

Non-Fibrous

Homogeneous

Between Window &

Brick Front Side -

Caulk

Page 8 of…