About this file

This file contains architectural drawings showing floor plans and elevations for an elevator modernization project at Fort Randall Dam Powerhouse in South Dakota. The drawings detail the renovation of existing passenger elevators, including floor plans at multiple elevations (1244.0, 1258.0, 1273.0, 1291.0, and 1307.0).

The drawings specify extensive upgrades including: replacement of elevator controllers/drives, governors, hoist machines, door operators, traveling cables, wire ropes, signal features, and safety equipment. Existing components to be retained include the car platform, guide rails, and some structural elements. The work includes repainting elevator lobby walls, refinishing/repairing doors and frames, replacing safety labels, and installing new call buttons and floor indicators. The elevator machine room at elevation 1307.0 will receive new HVAC equipment and fire-rated wall assemblies. The drawings include detailed demolition and new construction plans, with specific notes about protecting existing features during construction. These are revision 4 drawings dated January 22, 2025, prepared by the US Army Corps of Engineers Omaha District.

View the file

Other files for this federal contract opportunity

Other files attached to Fort Randall Powerhouse Elevator Replacement, newest first.
File Type Posted
14 21 23 Am-0004.pdf PDF
01 35 26 Am-0004.pdf PDF
AM0004 SF30 W9128F25R0008.pdf PDF
01 22 00 Am-0004.pdf PDF
AM0003 SF30 W9128F25R0008.pdf PDF
14 21 23 Am-0002.pdf PDF
AM0002 SF30 W9128F25R0008.pdf PDF
AM_0002 Drawings.pdf PDF
AM0001 SF30 W9128F25R0008.pdf PDF
AM0001_W9128F25R0008_Fort_Randall_Elevator_DRWG E-150.pdf PDF
09 90 00 Am-0001.pdf PDF
02 41 00 Am-0001.pdf PDF
14 21 23 Am-0001.pdf PDF
AM0001_W9128F25R0008_Fort_Randall_Elevator_DRWG_151.pdf PDF
01 35 26 Am-0001.pdf PDF
Site Visit Roster.pdf PDF
ATTACHMENT 2.pdf PDF
FR00108 - ADVERTISEMENT.PDF PDF
W9128F25R0008_Fort_Randall_Elevator_Specs.pdf PDF
W9128F25R0008.pdf PDF
Show all 20

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 2 3 4 5 6 7 8 9 10

A

B

D

F

G

H

J

1 2 3 4 5 7

8 9 10

2A 4A

J

H

GA

A

B

D

F

G

C

B-101

B-100

SPRINGS

EXISTING STEEL

UNITS

AND STRUCTURAL CLAY

HOISTWAY - CONCRETE

EXISTING ELEVATOR

TO BE REMOVED AND REPLACED

EXISTING STEEL LADDER

LOBBY

ELEVATOR

B-101

SHAFT

ELEVATOR

B-100

RAILS TO REMAIN

EXISTING STEEL GUIDE

A-301

B6

PROTECTION PLATE

COUNTERWEIGHTS

EXISTING STL.

EXISTING HOLES

SIZED TO COVER ANY

- BACK PLATE MUST BE

CALL BUTTON ASSEMBLY

REPLACE WITH A NEW

BUTTON ASSEMBLY AND

REMOVE EXISTING CALL

ANY EXISTING HOLES

SIZED TO COVER

BACK PLATE MUST BE

ASSEMBLIES -

NEW FLOOR INDICATOR

REPLACE WITH

ASSEMBLIES AND

FLOOR INDICATOR

REMOVE EXISTING

EXISTING DRAIN7

/1

ANY EXISTING HOLES

BE SIZED TO COVER

BACKER PLATE MUST

REPLACE "ELEVATOR" SIGN -

MAINTENANCE ASSEMBLY

FUNCTIONALITY OF EXISTING

PROTECT AND MAINTAIN

DURING PAINTING

PROTECT FLOOR

CORNER TO CORNER -

PAINT EAST-WEST FROM

CONCRETE FLOOR,

PAINT WALL TO 11'-6" ABOVE

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

IS

S

U E

D A

T E

S I Z

E

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

SHEET ID

®of Engineers

US Army Corps

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

A D

V E

R T

IS

E

M E

N T

B-101

B-100

SPRINGS

EXISTING STEEL

UNITS

AND STRUCTURAL CLAY

HOISTWAY - CONCRETE

EXISTING ELEVATOR

TO BE REMOVED AND REPLACED

EXISTING STEEL LADDER

LOBBY

ELEVATOR

B-101

SHAFT

ELEVATOR

B-100

RAILS TO REMAIN

EXISTING STEEL GUIDE

A-301

B6

PROTECTION PLATE

COUNTERWEIGHTS

EXISTING STL.

EXISTING HOLES

SIZED TO COVER ANY

- BACK PLATE MUST BE

CALL BUTTON ASSEMBLY

REPLACE WITH A NEW

BUTTON ASSEMBLY AND

REMOVE EXISTING CALL

ANY EXISTING HOLES

SIZED TO COVER

BACK PLATE MUST BE

ASSEMBLIES -

NEW FLOOR INDICATOR

REPLACE WITH

ASSEMBLIES AND

FLOOR INDICATOR

REMOVE EXISTING

EXISTING DRAIN7

/1

ANY EXISTING HOLES

BE SIZED TO COVER

BACKER PLATE MUST

REPLACE "ELEVATOR" SIGN -

MAINTENANCE ASSEMBLY

FUNCTIONALITY OF EXISTING

PROTECT AND MAINTAIN

DURING PAINTING

PROTECT FLOOR

CORNER TO CORNER -

PAINT EAST-WEST FROM

CONCRETE FLOOR,

PAINT WALL TO 11'-6" ABOVE

A N

S I

D

R E

P L

A C

E M

E N

T

P O

W E

R H

O U

S E

P A

S S

E N

G E

R E

L E

V A

T O

R

F O

R T

R A

N D

A L

L D

A M

S

O U

T H

D A

K O

T A

W F

R

N O

V E

M B

E R

O M

A H

A

N E

C A

P

IT

O L

A V

E

O M

A H

A D

IS

T

R

IC

T

F

IL

E

N U

M B

E R

F

IL

E N

A M

E

B

G O

R U

P

L

E V

A T

IO

N

.0

F L

O O

R P

L A

N

A-110

A F

O R

D

B

G O

R

A

-1 .d g n

F

O

R O

D U

C T

IO

N

D A

T A

P

R O

D U

C T

IO

N

D A

T A

P

R O

D U

C T

IO

N

D A

T A

P

R O

D U

C T

IO

N

D A

T A

B3

FLOOR PLAN - ELEVATION 1244.0

1/4"=1'-0"SCALE:

3 4 5 6

F G

REUSE AND REFURBISH OR REPLACE IF WORN.

VERIFY CONDITION OF EXISTING CAR BUFFERS AND COUNTERWEIGHT BUFFER.

THAT IS NOT ARCHITECTURAL IN NATURE.

23. SEE ALL OTHER TECHNICAL DISCIPLINES' DRAWINGS FOR ALL WORK

1273, AND 1291.

ELEVATOR LOBBY, REPAINT TO MATCH EXISTING. TYPICAL AT ELEVATIONS 1244, 1258,

22. REPAIR AND REFINISH ANY DAMAGE TO PLAN NORTH WALL OF

21. REPLACE SAFETY LABELS AT ALL FLOOR ELEVATIONS.

AND REQUIREMENTS.

SEE SPECIFICATION 14 21 23 FOR ADDITIONAL INFORMATION 20.

SUPPLY AND INSTALL NEW GOVERNOR TENSION WEIGHT.19.

18.

AT A MINIMUM, PROVIDE NEW WIRE ROPES AND FASTENERS.

EVALUATE, REUSE, AND REFURBISH EXISTING COUNTERWEIGHT. 17.

SUPPLY AND INSTALL NEW TRAVELING CABLE.16.

ENCLOSURE (FLOOR, WALLS, AND CEILING).

SUPPLY AND INSTALL NEW SAFETIES, TOE GUARD, AND INTERIOR CAB 15.

SUPPLY AND INSTALL NEW DOOR PROTECTION SYSTEM.14.

JAMB BRAILLE.

HALL STATIONS, HALL PL AT LEVEL 1 (ELEV 1273.0), AND PROVIDE

LIMITED TO MAIN CAR STATION, CAR DIRECTION LANTERNS,

PROVIDE NEW SIGNAL FEATURES INCLUDING BUT NOT13.

NOT USED.12.

NOT USED.11.

RETAIN EXISTING ELEVATOR CAR PLATFORM. 10.

SUPPLY AND INSTALL NEW DOOR OPERATORS.9.

ROPE GRIPPER, AND ADAPTER BEAMS.

SUPPLY AND INSTALL NEW HOIST MACHINE, MOTOR, ENCODER, BRAKE8.

SUPPLY AND INSTALL NEW HOIST ROPES.7.

SUPPLY AND INSTALL NEW GOVERNOR ROPE.6.

SUPPLY AND INSTALL NEW GOVERNOR.5.

SUPPLY AND INSTALL NEW ELEVATOR CONTROLLER/DRIVE.4.

DOOR ROLLERS AND DOOR MECHANISMS TO LIKE NEW QUALITY - TYP. ALL FLOORS.

FULLY REPAIR AND REFURBISH EXISTING ELEVATOR LOBBY 3.

DOORS ARE TO BE PAINTED AND FRAME IS TO REMAIN UNPAINTED.

COLORS. - TYPICAL ALL FLOORS OTHER THAN LEVEL 1 (ELEV 1273.0) WHERE

LOBBY/HOISTWAY DOORS AND FRAMES. MATCH EXISTING

SURFACE PREPARE AND PAINT EXISTING ELEVATOR 2.

REMOVE EXISTING STEEL PIT LADDER AND REPLACE. 1.

GENERAL NOTES:

SCALE: 1/4" = 1'-0"

0 4'4' 2'

M18

KEY PLAN

1"=40'SCALE:

-0

-2

A M

G

E N

E R

A L

R E

V

IS

IO

N

-2

-2

A M

G

E N

E R

A L

R E

V

IS

1 2 3 4 5 6 7 8 9 10

B

D

F

G

H

J

1 2 3 4 5 7

8 9 10

2A 4A

J

H

GA

A

B

D

F

G

C

LOBBY

ELEVATOR

A-101

A-101

A-100 A-100

SHAFT

ELEVATOR GUIDE RAILS TO REMAIN

EXISTING STEEL UNITS

AND STRUCTURAL CLAY

HOISTWAY - CONCRETE

EXISTING ELEVATOR

EXISTING HOLES

SIZED TO COVER ANY

- BACK PLATE MUST BE

CALL BUTTON ASSEMBLY

REPLACE WITH A NEW

BUTTON ASSEMBLY AND

REMOVE EXISTING CALL

ANY EXISTING HOLES

SIZED TO COVER

BACK PLATES MUST BE

ASSEMBLIES -

NEW FLOOR INDICATOR

REPLACE WITH

ASSEMBLIES AND

FLOOR INDICATOR

REMOVE EXISTING

ANY EXISTING HOLES

BE SIZED TO COVER

BACKER PLATE MUST

REPLACE "ELEVATOR" SIGN -

FLOOR DURING PAINTING

TO FLOOR - PROTECT

AND FROM CEILING

CORNER TO CORNER

PAINT WALL FROM

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

IS

S

U E

D A

T E

S I Z

E

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

SHEET ID

®of Engineers

US Army Corps

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

A D

V E

R T

IS

E

M E

N T

LOBBY

ELEVATOR

A-101

A-101

A-100 A-100

SHAFT

ELEVATOR GUIDE RAILS TO REMAIN

EXISTING STEEL UNITS

AND STRUCTURAL CLAY

HOISTWAY - CONCRETE

EXISTING ELEVATOR

EXISTING HOLES

SIZED TO COVER ANY

- BACK PLATE MUST BE

CALL BUTTON ASSEMBLY

REPLACE WITH A NEW

BUTTON ASSEMBLY AND

REMOVE EXISTING CALL

ANY EXISTING HOLES

SIZED TO COVER

BACK PLATES MUST BE

ASSEMBLIES -

NEW FLOOR INDICATOR

REPLACE WITH

ASSEMBLIES AND

FLOOR INDICATOR

REMOVE EXISTING

ANY EXISTING HOLES

BE SIZED TO COVER

BACKER PLATE MUST

REPLACE "ELEVATOR" SIGN -

FLOOR DURING PAINTING

TO FLOOR - PROTECT

AND FROM CEILING

CORNER TO CORNER

PAINT WALL FROM

A N

S

P L

A C

E M

E N

T

P O

W E

R H

O U

S E

P A

S S

E N

G E

R E

L E

V A

T O

R

F O

R T

R A

N D

A L

L D

A M

S

O U

T H

D A

K O

T A

W F

R

N O

V E

M B

E R

A H

A

N E

C A

P

IT

O L

A V

E

O M

A H

A D

IS

T

R

E

N U

M B

E R

F

IL

E N

A M

E

B

G O

R

E V

A T

IO

N

S

.0

A N

D

.0

F L

O O

R P

L A

N

A-120

A F

O R

D

B

G O

R

A

-1

.d

F

O

R O

D U

C T

IO

N

D A

T A

P

R O

D U

C T

IO

N

D A

T A

P

R O

D U

C T

IO

N

D A

T A

P

R O

D U

C T

IO

N

D A

T A

3 4 5 6 F

G

SCALE: 1/4" = 1'-0"

0 4'4' 2'

B3

FLOOR PLAN-ELEVATION 1258.0 AND 1262.0

1/4"=1'-0"SCALE:

REUSE AND REFURBISH OR REPLACE IF WORN.

VERIFY CONDITION OF EXISTING CAR BUFFERS AND COUNTERWEIGHT BUFFER.

DOORS ARE TO BE PAINTED AND FRAME IS TO REMAIN UNPAINTED.

COLORS. - TYPICAL ALL FLOORS OTHER THAN LEVEL 1 (ELEV 1273.0) WHERE

LOBBY/HOISTWAY DOORS AND FRAMES. MATCH EXISTING

SURFACE PREPARE AND PAINT EXISTING ELEVATOR 2.

THAT IS NOT ARCHITECTURAL IN NATURE.

23. SEE ALL OTHER TECHNICAL DISCIPLINES' DRAWINGS FOR ALL WORK

1273, AND 1291.

ELEVATOR LOBBY, REPAINT TO MATCH EXISTING. TYPICAL AT ELEVATIONS 1244, 1258,

22. REPAIR AND REFINISH ANY DAMAGE TO PLAN NORTH WALL OF

21. REPLACE SAFETY LABELS AT ALL FLOOR ELEVATIONS.

AND REQUIREMENTS.

SEE SPECIFICATION 14 21 23 FOR ADDITIONAL INFORMATION 20.

SUPPLY AND INSTALL NEW GOVERNOR TENSION WEIGHT.19.

18.

AT A MINIMUM, PROVIDE NEW WIRE ROPES AND FASTENERS.

EVALUATE, REUSE, AND REFURBISH EXISTING COUNTERWEIGHT. 17.

SUPPLY AND INSTALL NEW TRAVELING CABLE.16.

ENCLOSURE (FLOORS, WALLS, AND CEILING).

SUPPLY AND INSTALL NEW SAFETIES, TOE GUARD, AND INTERIOR CAB 15.

SUPPLY AND INSTALL NEW DOOR PROTECTION SYSTEM.14.

JAMB BRAILLE.

HALL STATIONS, HALL PLO AT LEVEL 1 (ELEV 1273.0), AND PROVIDE

LIMITED TO MAIN CAR STATION, CAR DIRECTION LANTERNS,

PROVIDE NEW SIGNAL FEATURES INCLUDING BUT NOT13.

NOT USED.12.

NOT USED.11.

RETAIN EXISTING ELEVATOR CAR PLATFORM. 10.

SUPPLY AND INSTALL NEW DOOR OPERATORS.9.

ROPE GRIPPER, AND ADAPTER BEAMS.

SUPPLY AND INSTALL NEW HOIST MACHINE, MOTOR, ENCODER, BRAKE8.

SUPPLY AND INSTALL NEW HOIST ROPES.7.

SUPPLY AND INSTALL NEW GOVERNOR ROPE.6.

SUPPLY AND INSTALL NEW GOVERNOR.5.

SUPPLY AND INSTALL NEW ELEVATOR CONTROLLER/DRIVE.4.

DOOR ROLLERS AND DOOR MECHANISMS TO LIKE NEW QUALITY - TYP. ALL FLOORS.

FULLY REPAIR AND REFURBISH EXISTING ELEVATOR LOBBY 3.

NOT USED.1.

GENERAL NOTES:

M18

KEYPLAN

1"=40'SCALE:

-0

-2

A M

G

E N

E R

A L

R E

V

IS

IO

N

-2

-2

A M

G

E N

E R

A L

R E

V

IS

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

IS

S

U E

D A

T E

S I Z

E

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

SHEET ID

®of Engineers

US Army Corps

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

A D

V E

R T

IS

E

M E

N T

GUIDE RAILS TO REMAIN

EXISTING STEEL

1-100 1-100

SHAFT

ELEVATOR

UNITS

AND STRUCTURAL CLAY

HOISTWAY - CONCRETE

EXISTING ELEVATOR

1-101

LOBBY

ELEVATOR

1-101

B5

B9

A-130 A-300

A-130 A-300

B14

A-130 A-300

A-301

B6

ANY EXISTING HOLES

MUST BE SIZED TO COVER

- BACK PLATE

CALL BUTTON ASSEMBLY

REPLACE WITH A NEW

BUTTON ASSEMBLY AND

REMOVE EXISTING CALL

ANY EXISTING HOLES

SIZED TO COVER

BACK PLATES MUST BE

ASSEMBLIES -

NEW FLOOR INDICATOR

REPLACE WITH

ASSEMBLIES AND

FLOOR INDICATOR

REMOVE EXISTING

EXISTING HOLES

COVER ANY

MUST BE SIZED TO

SIGN - BACK PLATE

REPLACE ELEVATOR

MAINTENANCE ASSEMBLY

FUNCTIONALITY OF EXISTING

PROTECT AND MAINTAIN

CORNER

PAINT FROM CORNER TO

UP TO TRIM, EAST-WEST

PAINT FROM TOP OF TILE

DURING PAINTING

- PROTECT FLOOR

1 2 3 4 5 6 7 8 9 10

A

B

D

F

G

H

J

1 2 3 4 5 7

8 9 10

2A 4A

J

H

GA

A

B

D

F

G

GUIDE RAILS TO REMAIN

EXISTING STEEL

1-100 1-100

SHAFT

ELEVATOR

UNITS

AND STRUCTURAL CLAY

HOISTWAY - CONCRETE

EXISTING ELEVATOR

1-101

LOBBY

ELEVATOR

1-101

B5

B9

A-130 A-300

A-130 A-300

B14

A-130 A-300

A-301

B6

ANY EXISTING HOLES

MUST BE SIZED TO COVER

- BACK PLATE

CALL BUTTON ASSEMBLY

REPLACE WITH A NEW

BUTTON ASSEMBLY AND

REMOVE EXISTING CALL

ANY EXISTING HOLES

SIZED TO COVER

BACK PLATES MUST BE

ASSEMBLIES -

NEW FLOOR INDICATOR

REPLACE WITH

ASSEMBLIES AND

FLOOR INDICATOR

REMOVE EXISTING

EXISTING HOLES

COVER ANY

MUST BE SIZED TO

SIGN - BACK PLATE

REPLACE ELEVATOR

MAINTENANCE ASSEMBLY

FUNCTIONALITY OF EXISTING

PROTECT AND MAINTAIN

CORNER

PAINT FROM CORNER TO

UP TO TRIM, EAST-WEST

PAINT FROM TOP OF TILE

DURING PAINTING

- PROTECT FLOOR

A N

S

P L

A C

E M

E N

T

P O

W E

R H

O U

S E

P A

S S

E N

G E

R E

L E

V A

T O

R

F O

R T

R A

N D

A L

L D

A M

S

O U

T H

D A

K O

T A

W F

R

N O

V E

M B

E R

A H

A

N E

C A

P

IT

O L

A V

E

O M

A H

A D

IS

T

R

E

N U

M B

E R

F

IL

E N

A M

E

B

G O

R

E V

A T

IO

N

.0

F L

O O

R P

L A

N

A-130

A F

O R

D

B

G O

R

A

-1

.d

F

O

R O

D U

C T

IO

N

D A

T A

P

R O

D U

C T

IO

N

D A

T A

P

R O

D U

C T

IO

N

D A

T A

P

R O

D U

C T

IO

N

D A

T A

SCALE: 1/4" = 1'-0"

0 4'4' 2'

REUSE AND REFURBISH OR REPLACE IF WORN.

VERIFY CONDITION OF EXISTING CAR BUFFERS AND COUNTERWEIGHT BUFFER.

DOORS ARE TO BE PAINTED AND FRAME IS TO REMAIN UNPAINTED.

COLORS. - TYPICAL ALL FLOORS OTHER THAN LEVEL 1 (ELEV 1273.0) WHERE

LOBBY/HOISTWAY DOORS AND FRAMES. MATCH EXISTING

SURFACE PREPARE AND PAINT EXISTING ELEVATOR 2.

THAT IS NOT ARCHITECTURAL IN NATURE.

23. SEE ALL OTHER TECHNICAL DISCIPLINES' DRAWINGS FOR ALL WORK

1244, 1258, 1273, AND 1291.

ELEVATOR LOBBY, REPAINT TO MATCH EXISTING. - TYPICAL AT ELEVATIONS

22. REPAIR AND REFINISH ANY DAMAGE TO PLAN NORTH WALL OF

21. REPLACE SAFETY LABELS AT ALL FLOOR ELEVATIONS.

AND REQUIREMENTS.

SEE SPECIFICATION 14 21 23 FOR ADDITIONAL INFORMATION 20.

SUPPLY AND INSTALL NEW GOVERNOR TENSION WEIGHT.19.

18.

AT A MINIMUM, PROVIDE NEW WIRE ROPES AND FASTENERS.

EVALUATE, REUSE, AND REFURBISH EXISTING COUNTERWEIGHT. 17.

SUPPLY AND INSTALL NEW TRAVELING CABLE.16.

ENCLOSURE (FLOOR, WALLS, AND CEILING).

SUPPLY AND INSTALL NEW SAFETIES, TOE GUARD, AND INTERIOR CAB 15.

SUPPLY AND INSTALL NEW DOOR PROTECTION SYSTEM.14.

JAMB BRAILLE.

HALL STATIONS, HALL PL AT LEVEL 1 (ELEV 1273.0), AND PROVIDE

LIMITED TO MAIN CAR STATION, CAR DIRECTION LANTERNS,

PROVIDE NEW SIGNAL FEATURES INCLUDING BUT NOT13.

NOT USED.12.

NOT USED.11.

RETAIN EXISTING ELEVATOR CAR PLATFORM. 10.

SUPPLY AND INSTALL NEW DOOR OPERATORS.9.

ROPE GRIPPER, AND ADAPTER BEAMS.

SUPPLY AND INSTALL NEW HOIST MACHINE, MOTOR, ENCODER, BRAKE8.

SUPPLY AND INSTALL NEW HOIST ROPES.7.

SUPPLY AND INSTALL NEW GOVERNOR ROPE.6.

SUPPLY AND INSTALL NEW GOVERNOR.5.

SUPPLY AND INSTALL NEW ELEVATOR CONTROLLER/DRIVE.4.

DOOR ROLLERS AND DOOR MECHANISMS TO LIKE NEW QUALITY - TYP. ALL FLOORS.

FULLY REPAIR AND REFURBISH EXISTING ELEVATOR LOBBY 3.

NOT USED.1.

GENERAL NOTES:

C5

FLOOR PLAN - ELEVATION 1273.0

1/4"=1'-0"SCALE:

M16

KEY PLAN

1"=40'SCALE:

-0

-2

A M

G

E N

E R

A L

R E

V

IS

IO

N

-2

-2

A M

G

E N

E R

A L

R E

V

IS

B

C

D

E

F

G

H

J

K

L

M

N

P

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

IS

S

U E

D A

T E

S I Z

E

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

SHEET ID

®of Engineers

US Army Corps

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

A D

V E

R T

IS

E

M E

N T

B14

A-140 A-300

UNITS

AND STRUCTURAL CLAY

HOISTWAY - CONCRETE

EXISTING ELEVATOR

REMAIN

GUIDE RAILS TO

EXISTING STEEL

2-100 2-100

SHAFT

ELEVATOR

2-101

LOBBY

ELEVATOR

2-101

B5

B9

A-140 A-300

A-300A-140

A-301

B6

PLATE TO MATCH ENTRY

- PAINT ADDITIONAL MISC.

ANY EXISTING HOLES

MUST BE SIZED TO COVER

ASSEMBLIES - BACK PLATES

NEW FLOOR INDICATOR

REPLACE WITH

ASSEMBLIES AND

FLOOR INDICATOR

REMOVE EXISTING

ANY EXISTING HOLES

MUST BE SIZED TO COVER

- BACK PLATE

CALL BUTTON ASSEMBLY

REPLACE WITH A NEW

BUTTON ASSEMBLY AND

REMOVE EXISTING CALL

ANY EXISTING HOLES

BE SIZED TO COVER

BACK PLATE MUST

REPLACE "ELEVATOR" SIGN -

ASSEMBLY

EXISTING MAINTENANCE

FUNCTIONALITY OF

PROTECT AND MAINTAIN

PAINTING

FLOOR DURING

FLOOR - PROTECT

AND FROM CEILING TO

CORNER TO CORNER

PAINT WALL FROM

1 2 3 4 5 6 7 8 9 10

A

B

D

F

G

H

J

1 2 3 4 5 7

8 9 10

2A 4A

J

H

GA

A

B

D

F

G

B14

A-140 A-300

UNITS

AND STRUCTURAL CLAY

HOISTWAY - CONCRETE

EXISTING ELEVATOR

REMAIN

GUIDE RAILS TO

EXISTING STEEL

2-100 2-100

SHAFT

ELEVATOR

2-101

LOBBY

ELEVATOR

2-101

B5

B9

A-140 A-300

A-300A-140

A-301

B6

PLATE TO MATCH ENTRY

- PAINT ADDITIONAL MISC.

ANY EXISTING HOLES

MUST BE SIZED TO COVER

ASSEMBLIES - BACK PLATES

NEW FLOOR INDICATOR

REPLACE WITH

ASSEMBLIES AND

FLOOR INDICATOR

REMOVE EXISTING

ANY EXISTING HOLES

MUST BE SIZED TO COVER

- BACK PLATE

CALL BUTTON ASSEMBLY

REPLACE WITH A NEW

BUTTON ASSEMBLY AND

REMOVE EXISTING CALL

ANY EXISTING HOLES

BE SIZED TO COVER

BACK PLATE MUST

REPLACE "ELEVATOR" SIGN -

ASSEMBLY

EXISTING MAINTENANCE

FUNCTIONALITY OF

PROTECT AND MAINTAIN

PAINTING

FLOOR DURING

FLOOR - PROTECT

AND FROM CEILING TO

CORNER TO CORNER

PAINT WALL FROM

A N

S

P L

A C

E M

E N

T

P O

W E

R H

O U

S E

P A

S S

E N

G E

R E

L E

V A

T O

R

F O

R T

R A

N D

A L

L D

A M

S

O U

T H

D A

K O

T A

W F

R

N O

V E

M B

E R

A H

A

N E

C A

P

IT

O L

A V

E

O M

A H

A D

IS

T

R

E

N U

M B

E R

F

IL

E N

A M

E

B

G O

R

E V

A T

IO

N

.0

F L

O O

R P

L A

N

A-140

A F

O R

D

B

G O

R

A

-1

.d

F

O

R O

D U

C T

IO

N

D A

T A

P

R O

D U

C T

IO

N

D A

T A

P

R O

D U

C T

IO

N

D A

T A

P

R O

D U

C T

IO

N

D A

T A

SCALE: 1/4" = 1'-0"

0 4'4' 2'

REUSE AND REFURBISH OR REPLACE IF WORN.

VERIFY CONDITION OF EXISTING CAR BUFFERS AND COUNTERWEIGHT BUFFER.

DOORS ARE TO BE PAINTED AND FRAME IS TO REMAIN UNPAINTED.

COLORS. - TYPICAL ALL FLOORS OTHER THAN LEVEL 1 (ELEV 1273.0) WHERE

LOBBY/HOISTWAY DOORS AND FRAMES. MATCH EXISTING

SURFACE PREPARE AND PAINT EXISTING ELEVATOR 2.

THAT IS NOT ARCHITECTURAL IN NATURE.

23. SEE ALL OTHER TECHNICAL DISCIPLINES' DRAWINGS FOR ALL WORK

1273, AND 1291.

ELEVATOR LOBBY, REPAINT TO MATCH EXISTING. TYPICAL AT ELEVATIONS 1244, 1258,

22. REPAIR AND REFINISH ANY DAMAGE TO PLAN NORTH WALL OF

21. REPLACE SAFETY LABELS AT ALL FLOOR ELEVATIONS.

AND REQUIREMENTS.

SEE SPECIFICATION 14 21 23 FOR ADDITIONAL INFORMATION 20.

SUPPLY AND INSTALL NEW GOVERNOR TENSION WEIGHT.19.

18.

AT A MINIMUM, PROVIDE NEW WIRE ROPES AND FASTENERS.

EVALUATE, REUSE, AND REFURBISH EXISTING COUNTERWEIGHT. 17.

SUPPLY AND INSTALL NEW TRAVELING CABLE.16.

ENCLOSURE (FLOORS, WALLS, AND CEILING).

SUPPLY AND INSTALL NEW SAFETIES, TOE GUARD, AND INTERIOR CAB 15.

SUPPLY AND INSTALL NEW DOOR PROTECTION SYSTEM.14.

JAMB BRAILLE.

HALL STATIONS, HALL PL AT LEVEL 1 (ELEV 1273.0), AND PROVIDE

LIMITED TO MAIN CAR STATION, CAR DIRECTION LANTERNS,

PROVIDE NEW SIGNAL FEATURES INCLUDING BUT NOT13.

NOT USED.12.

NOT USED.11.

RETAIN EXISTING ELEVATOR CAR PLATFORM. 10.

SUPPLY AND INSTALL NEW DOOR OPERATORS.9.

ROPE GRIPPER, AND ADAPTER BEAMS.

SUPPLY AND INSTALL NEW HOIST MACHINE, MOTOR, ENCODER, BRAKE8.

SUPPLY AND INSTALL NEW HOIST ROPES.7.

SUPPLY AND INSTALL NEW GOVERNOR ROPE.6.

SUPPLY AND INSTALL NEW GOVERNOR.5.

SUPPLY AND INSTALL NEW ELEVATOR CONTROLLER/DRIVE.4.

DOOR ROLLERS AND DOOR MECHANISMS TO LIKE NEW QUALITY - TYP. ALL FLOORS.

FULLY REPAIR AND REFURBISH EXISTING ELEVATOR LOBBY 3.

NOT USED.1.

GENERAL NOTES:

C5

FLOOR PLAN - ELEVATION 1291.0

1/4"=1'-0"SCALE:

M16

KEY PLAN

1"=40'SCALE:

A M

G

E N

E R

A L

R E

V

IS

IO

N

-0

-2

-2

-2

A M

G

E N

E R

A L

R E

V

IS

B

C

D

E

F

G

H

J

K

L

M

N

P

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

IS

S

U E

D A

T E

S I Z

E

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

SHEET ID

®of Engineers

US Army Corps

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

A D

V E

R T

IS

E

M E

N T

ROOM ELEVATION 1307.0 - DEMOLITION

EXISTING FLOOR PLAN - ELEVATOR MACHINE

4 65

F

G

D

B

A

4 65

B

A

D

F

G

ROOM ELEVATION 1307.0 -

FLOOR PLAN - ELEVATOR MACHINE

MACHINERY

EXISTING ELEVATOR

JOINT

CONSTRUCTION

EXISTING

GRATING

EXISTING

CONC WALL

EXISTING

CLAY UNITS

EXISTING STRUCTURAL

AND GUARDRAILS

EXISTING STAIRS

LOUVERS

ALUMINUM

EXISTING

OVERLOADING

AND PROTECT FROM

CONTRACTOR TO AVOID

CAPACITY UNKNOWN,

EXISTING HATCH COVER -

AND GUARDRAILS

EXISTING STAIRS

CATWALK

EXISTING

LADDER

EXISTING

AT ELEVATION 1318.17

EXISTING LANDING

STACK

INCINERATOR

EXISTING

- TYP.

DUCT OPENING

EXISTING

BASES - TYP.

EXISTING FAN

DUCT OPENING

EXISTING

LOUVER

ALUMINUM

EXISTING

JOINT

CONSTRUCTION

EXISTING

7'-11"10'-8"

EM1

MACHINE ROOM

ELEVATOR

MOVING INTO POSITION

TO BE ACCESSED WHILE

HATCHES, AND STAIRWELLS

SIZE WITH ALL DOORS,

EQUIPMENT - COORDINATE

NEW ELEVATOR

REFERENCE UL DESIGN U437

TO ENSURE 2-HOUR FIRE RATING

SHAFTWALL CORE BD. -

AND ONE LAYER OF 1" GYP

OF 5/8" TYPE "X" GWB

SET BETWEEN TWO LAYERS

(OR AS REQUIRED FOR SPAN)

WITH STEEL STUDS @ 24" O.C.

6" SHAFTWALL ASSEMBLY

AND FRAME ASSEMBLY

90 MINUTE F.R DOOR

INTAKE CEILING

FRESH AIR

EXISTING

OUTLINE OF

REMOVED

CONDUIT WAS

FLOOR WHERE

IN EXIST. CONC.

PATCH OPENING

BELOW

EXISTING ROOF

STR. & MECH.

DUCTWORK- SEE

SYSTEM

PRESSURIZATION

HOISTWAY

OPENING FOR

ENLARGED FLOOR

MECH. AND STR.

NEW DUCT - SEE

CONC. FLOOR FOR

OPENING IN EXIST.

NEW +/- 1'-0" X 1'-0"

E M

FLOOR - PATCH

OPENING IN

EXISTING 4"X4"

SPECIFICATIONS

IN ACCORDANCE TO THE

APPLY PAINT AND TEXTURE

1 2 3 4 5 6 7 8 9 10

A

B

D

F

G

H

J

1 2 3 4 5 72A 4A

A

B

D

F

G

11 12 13 14 15 16 17 18 2019 21 22 23 24 25 26 27 28 29 30 32 33 34 3531 37 38 39 4036 42 43 44 4541 47 48 49 5046 51

GA

ON C/A-300 AND M-501.

METAL DUCT AS SHOWN

CAP. INSTALL NEW SHEET

CURB AND SHEET METAL

OPENING WITH ROOF

EXISTING +/- 2'-0" X 1'-6"

WORK

PROTECT DURING

ROOF ASSEMBLY-

EXISTING EPDM

S L

O P

E

WORK

PROTECT DURING

ROOF BELOW -

EXISTING EPDM

EXPANSION JOINT

EXISTING BUILDING

A N

S

P L

A C

E M

E N

T

P O

W E

R H

O U

S E

P A

S S

E N

G E

R E

L E

V A

T O

R

F O

R T

R A

N D

A L

L D

A M

S

O U

T H

D A

K O

T A

W F

R

N O

V E

M B

E R

A H

A

N E

C A

P

IT

O L

A V

E

O M

A H

A D

IS

T

R

E

N U

M B

E R

F

IL

E N

A M

E

B

G O

R

E V

A T

IO

N

.0

F L

O O

R P

L A

N

A-150

A F

O R

D

B

G O

R

A

-1

.d

F

O

R O

D U

C T

IO

N

D A

T A

P

R O

D U

C T

IO

N

D A

T A

P

R O

D U

C T

IO

N

D A

T A

P

R O

D U

C T

IO

N

D A

T A

M15

KEY PLAN

1"=80'SCALE:

REUSE AND REFURBISH OR REPLACE IF WORN.

VERIFY CONDITION OF EXISTING CAR BUFFERS AND COUNTERWEIGHT BUFFER.

THAT IS NOT ARCHITECTURAL IN NATURE.

23. SEE ALL OTHER TECHNICAL DISCIPLINES' DRAWINGS FOR ALL WORK

1273, AND 1291.

ELEVATOR LOBBY, REPAINT TO MATCH EXISTING. TYPICAL AT ELEVATIONS 1244, 1258,

22. REPAIR AND REFINISH ANY DAMAGE TO PLAN NORTH WALL OF

21. REPLACE SAFETY LABELS AT ALL FLOOR ELEVATIONS.

AND REQUIREMENTS.

SEE SPECIFICATION 14 21 23 FOR ADDITIONAL INFORMATION 20.

SUPPLY AND INSTALL NEW GOVERNOR TENSION WEIGHT.19.

18.

AT A MINIMUM, PROVIDE NEW WIRE ROPES AND FASTENERS.

EVALUATE, REUSE, AND REFURBISH EXISTING COUNTERWEIGHT. 17.

SUPPLY AND INSTALL NEW TRAVELING CABLE.16.

NOT USED.15.

SUPPLY AND INSTALL NEW DOOR PROTECTION SYSTEM.14.

NOT USED.13.

NOT USED.12.

NOT USED.11.

NOT USED.10.

NOT USED.9.

ROPE GRIPPER, AND ADAPTER BEAMS.

SUPPLY AND INSTALL NEW HOIST MACHINE, MOTOR, ENCODER, BRAKE8.

SUPPLY AND INSTALL NEW HOIST ROPES.7.

SUPPLY AND INSTALL NEW GOVERNOR ROPE.6.

SUPPLY AND INSTALL NEW GOVERNOR.5.

SUPPLY AND INSTALL NEW ELEVATOR CONTROLLER/DRIVE.4.

NOT USED.3.

NOT USED. 2.

NOT USED.1.

GENERAL NOTES:

A

M

G E

N E

R A

L R

E V

IS

IO

N S

-0

-2

-2

-2

A M

G

E N

E R

A L

R E

V

IS

FR00108A-110
FR00108A-120
FR00108A-130
FR00108A-140
FR00108A-150

File details come from the government source that posted it. Updated .