AM_0002 Drawings.pdf
PDF 2 MB Posted
- Attached to
- Fort Randall Powerhouse Elevator Replacement Federal contract opportunity
- Solicitation number
- W9128F25R0008
About this file
These are architectural and mechanical drawings for an elevator replacement project at Fort Randall Dam's powerhouse in South Dakota (solicitation W9128F25R0008). The drawings show floor plans, elevations, and mechanical details for replacing an existing passenger elevator that services multiple levels from elevation 1244.0 to 1291.0, with a machine room at elevation 1307.0.
The drawings detail specific requirements including: installation of a new elevator controller/drive, governor, hoist machine, motor, encoder, brake components, door operators, traveling cable, counterweight, buffers, and door protection systems; replacement of all signal features including car station, direction lanterns, and hall stations; repainting of elevator lobby walls and doors at all floor levels; and installation of a new HVAC system in the machine room including an inline pressurization fan (SF-1) rated at 3100 CFM, wall-mounted exhaust fan (EF-1) rated at 1600 CFM, and a 3kW electric unit heater. The drawings also specify maintaining existing elevator guide rails while replacing or refurbishing various other components throughout the hoistway and at each landing.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| AM0004 SF30 W9128F25R0008.pdf | ||
| 01 22 00 Am-0004.pdf | ||
| 01 35 26 Am-0004.pdf | ||
| AM_0004 Drawings.pdf | ||
| 14 21 23 Am-0004.pdf | ||
| AM0003 SF30 W9128F25R0008.pdf | ||
| AM0002 SF30 W9128F25R0008.pdf | ||
| 14 21 23 Am-0002.pdf | ||
| AM0001_W9128F25R0008_Fort_Randall_Elevator_DRWG_151.pdf | ||
| 01 35 26 Am-0001.pdf | ||
| AM0001 SF30 W9128F25R0008.pdf | ||
| AM0001_W9128F25R0008_Fort_Randall_Elevator_DRWG E-150.pdf | ||
| 09 90 00 Am-0001.pdf | ||
| 02 41 00 Am-0001.pdf | ||
| 14 21 23 Am-0001.pdf | ||
| Site Visit Roster.pdf | ||
| FR00108 - ADVERTISEMENT.PDF | ||
| W9128F25R0008_Fort_Randall_Elevator_Specs.pdf | ||
| W9128F25R0008.pdf | ||
| ATTACHMENT 2.pdf |
Show all 20
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A N
S I
D
R E
P L
A C
E M
E N
T
P O
W E
R H
O U
S E
P A
S S
E N
G E
R E
L E
V A
T O
R
F O
R T
R A
N D
A L
L D
A M
S
O U
T H
D A
K O
T A
W F
R
N O
V E
M B
E R
O M
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
IC
T
F
IL
E
N U
M B
E R
F
IL
E N
A M
E
J
S W
E R
C Z
K
C
V E
R
I N
D E
X
G-001
M H
O F
F M
A N
J
S W
E R
C Z
E K
-0
-2
G E
N E
R A
L R
E V
IS
IO
R
G
-0
.d g n
H
O F
F M
S
P
D
:1
:5
A
M
/8 /2
F R
G
-0 .d
REPLACEMENT
POWERHOUSE PASSENGER ELEVATOR
FORT RANDALL DAM, SOUTH DAKOTA
W9128F25R0008
NOVEMBER 2024
OMAHA DISTRICT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A D
V E
R T
IS
E
M E
N T
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
of Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
B
D
F
G
H
J
1 2 3 4 5 7
8 9 10
2A 4A
J
H
GA
A
B
D
F
G
C
B-101
B-100
SPRINGS
EXISTING STEEL
UNITS
AND STRUCTURAL CLAY
HOISTWAY - CONCRETE
EXISTING ELEVATOR
TO BE REMOVED AND REPLACED
EXISTING STEEL LADDER
LOBBY
ELEVATOR
B-101
SHAFT
ELEVATOR
B-100
RAILS TO REMAIN
EXISTING STEEL GUIDE
A-301
B6
PROTECTION PLATE
COUNTERWEIGHTS
EXISTING STL.
EXISTING HOLES
SIZED TO COVER ANY
- BACK PLATE MUST BE
CALL BUTTON ASSEMBLY
REPLACE WITH A NEW
BUTTON ASSEMBLY AND
REMOVE EXISTING CALL
ANY EXISTING HOLES
SIZED TO COVER
BACK PLATE MUST BE
ASSEMBLIES -
NEW FLOOR INDICATOR
REPLACE WITH
ASSEMBLIES AND
FLOOR INDICATOR
REMOVE EXISTING
EXISTING DRAIN7
/1
ANY EXISTING HOLES
BE SIZED TO COVER
BACKER PLATE MUST
REPLACE "ELEVATOR" SIGN -
MAINTENANCE ASSEMBLY
FUNCTIONALITY OF EXISTING
PROTECT AND MAINTAIN
DURING PAINTING
PROTECT FLOOR
CORNER TO CORNER -
PAINT EAST-WEST FROM
CONCRETE FLOOR,
PAINT WALL TO 11'-6" ABOVE
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A D
V E
R T
IS
E
M E
N T
B-101
B-100
SPRINGS
EXISTING STEEL
UNITS
AND STRUCTURAL CLAY
HOISTWAY - CONCRETE
EXISTING ELEVATOR
TO BE REMOVED AND REPLACED
EXISTING STEEL LADDER
LOBBY
ELEVATOR
B-101
SHAFT
ELEVATOR
B-100
RAILS TO REMAIN
EXISTING STEEL GUIDE
A-301
B6
PROTECTION PLATE
COUNTERWEIGHTS
EXISTING STL.
EXISTING HOLES
SIZED TO COVER ANY
- BACK PLATE MUST BE
CALL BUTTON ASSEMBLY
REPLACE WITH A NEW
BUTTON ASSEMBLY AND
REMOVE EXISTING CALL
ANY EXISTING HOLES
SIZED TO COVER
BACK PLATE MUST BE
ASSEMBLIES -
NEW FLOOR INDICATOR
REPLACE WITH
ASSEMBLIES AND
FLOOR INDICATOR
REMOVE EXISTING
EXISTING DRAIN7
/1
ANY EXISTING HOLES
BE SIZED TO COVER
BACKER PLATE MUST
REPLACE "ELEVATOR" SIGN -
MAINTENANCE ASSEMBLY
FUNCTIONALITY OF EXISTING
PROTECT AND MAINTAIN
DURING PAINTING
PROTECT FLOOR
CORNER TO CORNER -
PAINT EAST-WEST FROM
CONCRETE FLOOR,
PAINT WALL TO 11'-6" ABOVE
A N
S
P L
A C
E M
E N
T
P O
W E
R H
O U
S E
P A
S S
E N
G E
R E
L E
V A
T O
R
F O
R T
R A
N D
A L
L D
A M
S
O U
T H
D A
K O
T A
W F
R
N O
V E
M B
E R
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
E
N U
M B
E R
F
IL
E N
A M
E
B
G O
R U
P
L
E V
A T
IO
N
.0
F L
O O
R P
L A
N
A-110
A F
O R
D
B
G O
R
A
-1 .d
F
O
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
B3
FLOOR PLAN - ELEVATION 1244.0
1/4"=1'-0"SCALE:
3 4 5 6
F G
THAT IS NOT ARCHITECTURAL IN NATURE.
23. SEE ALL OTHER TECHNICAL DISCIPLINES' DRAWINGS FOR ALL WORK
1273, AND 1291.
ELEVATOR LOBBY, REPAINT TO MATCH EXISTING. TYPICAL AT ELEVATIONS 1244, 1258,
22. REPAIR AND REFINISH ANY DAMAGE TO PLAN NORTH WALL OF
21. REPLACE SAFETY LABELS AT ALL FLOOR ELEVATIONS.
AND REQUIREMENTS.
SEE SPECIFICATION 14 21 23 FOR ADDITIONAL INFORMATION 20.
SUPPLY AND INSTALL NEW GOVERNOR TENSION WEIGHT.19.
REPLACE CAR AND COUNTERWEIGHT BUFFERS.18.
REPLACE EXISTING COUNTERWEIGHT.17.
SUPPLY AND INSTALL NEW TRAVELING CABLE.16.
ENCLOSURE (FLOOR, WALLS, AND CEILING).
SUPPLY AND INSTALL NEW SAFETIES, TOE GUARD, AND INTERIOR CAB 15.
SUPPLY AND INSTALL NEW DOOR PROTECTION SYSTEM.14.
JAMB BRAILLE.
HALL STATIONS, HALL PL AT LEVEL 1 (ELEV 1273.0), AND PROVIDE
LIMITED TO MAIN CAR STATION, CAR DIRECTION LANTERNS,
PROVIDE NEW SIGNAL FEATURES INCLUDING BUT NOT13.
NOT USED.12.
NOT USED.11.
RETAIN EXISTING ELEVATOR CAR PLATFORM. 10.
SUPPLY AND INSTALL NEW DOOR OPERATORS.9.
ROPE GRIPPER, AND ADAPTER BEAMS.
SUPPLY AND INSTALL NEW HOIST MACHINE, MOTOR, ENCODER, BRAKE8.
SUPPLY AND INSTALL NEW HOIST ROPES.7.
SUPPLY AND INSTALL NEW GOVERNOR ROPE.6.
SUPPLY AND INSTALL NEW GOVERNOR.5.
SUPPLY AND INSTALL NEW ELEVATOR CONTROLLER/DRIVE.4.
DOOR ROLLERS AND DOOR MECHANISMS TO LIKE NEW QUALITY - TYP. ALL FLOORS.
FULLY REPAIR AND REFURBISH EXISTING ELEVATOR LOBBY 3.
DOORS ARE TO BE PAINTED AND FRAME IS TO REMAIN UNPAINTED.
COLORS. - TYPICAL ALL FLOORS OTHER THAN LEVEL 1 (ELEV 1273.0) WHERE
LOBBY/HOISTWAY DOORS AND FRAMES. MATCH EXISTING
SURFACE PREPARE AND PAINT EXISTING ELEVATOR 2.
REMOVE EXISTING STEEL PIT LADDER AND REPLACE. 1.
GENERAL NOTES:
SCALE: 1/4" = 1'-0"
0 4'4' 2'
M18
KEY PLAN
1"=40'SCALE:
-0
-2
A M
G
E N
E R
A L
R E
V
IS
IO
1 2 3 4 5 6 7 8 9 10
B
D
F
G
H
J
1 2 3 4 5 7
8 9 10
2A 4A
J
H
GA
A
B
D
F
G
C
LOBBY
ELEVATOR
A-101
A-101
A-100 A-100
SHAFT
ELEVATOR GUIDE RAILS TO REMAIN
EXISTING STEEL UNITS
AND STRUCTURAL CLAY
HOISTWAY - CONCRETE
EXISTING ELEVATOR
EXISTING HOLES
SIZED TO COVER ANY
- BACK PLATE MUST BE
CALL BUTTON ASSEMBLY
REPLACE WITH A NEW
BUTTON ASSEMBLY AND
REMOVE EXISTING CALL
ANY EXISTING HOLES
SIZED TO COVER
BACK PLATES MUST BE
ASSEMBLIES -
NEW FLOOR INDICATOR
REPLACE WITH
ASSEMBLIES AND
FLOOR INDICATOR
REMOVE EXISTING
ANY EXISTING HOLES
BE SIZED TO COVER
BACKER PLATE MUST
REPLACE "ELEVATOR" SIGN -
FLOOR DURING PAINTING
TO FLOOR - PROTECT
AND FROM CEILING
CORNER TO CORNER
PAINT WALL FROM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A D
V E
R T
IS
E
M E
N T
LOBBY
ELEVATOR
A-101
A-101
A-100 A-100
SHAFT
ELEVATOR GUIDE RAILS TO REMAIN
EXISTING STEEL UNITS
AND STRUCTURAL CLAY
HOISTWAY - CONCRETE
EXISTING ELEVATOR
EXISTING HOLES
SIZED TO COVER ANY
- BACK PLATE MUST BE
CALL BUTTON ASSEMBLY
REPLACE WITH A NEW
BUTTON ASSEMBLY AND
REMOVE EXISTING CALL
ANY EXISTING HOLES
SIZED TO COVER
BACK PLATES MUST BE
ASSEMBLIES -
NEW FLOOR INDICATOR
REPLACE WITH
ASSEMBLIES AND
FLOOR INDICATOR
REMOVE EXISTING
ANY EXISTING HOLES
BE SIZED TO COVER
BACKER PLATE MUST
REPLACE "ELEVATOR" SIGN -
FLOOR DURING PAINTING
TO FLOOR - PROTECT
AND FROM CEILING
CORNER TO CORNER
PAINT WALL FROM
A N
S
P L
A C
E M
E N
T
P O
W E
R H
O U
S E
P A
S S
E N
G E
R E
L E
V A
T O
R
F O
R T
R A
N D
A L
L D
A M
S
O U
T H
D A
K O
T A
W F
R
N O
V E
M B
E R
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
E
N U
M B
E R
F
IL
E N
A M
E
B
G O
R
E V
A T
IO
N
S
.0
A N
D
.0
F L
O O
R P
L A
N
A-120
A F
O R
D
B
G O
R
A
-1
.d
F
O
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
3 4 5 6 F
G
SCALE: 1/4" = 1'-0"
0 4'4' 2'
B3
FLOOR PLAN-ELEVATION 1258.0 AND 1262.0
1/4"=1'-0"SCALE:
DOORS ARE TO BE PAINTED AND FRAME IS TO REMAIN UNPAINTED.
COLORS. - TYPICAL ALL FLOORS OTHER THAN LEVEL 1 (ELEV 1273.0) WHERE
LOBBY/HOISTWAY DOORS AND FRAMES. MATCH EXISTING
SURFACE PREPARE AND PAINT EXISTING ELEVATOR 2.
THAT IS NOT ARCHITECTURAL IN NATURE.
23. SEE ALL OTHER TECHNICAL DISCIPLINES' DRAWINGS FOR ALL WORK
1273, AND 1291.
ELEVATOR LOBBY, REPAINT TO MATCH EXISTING. TYPICAL AT ELEVATIONS 1244, 1258,
22. REPAIR AND REFINISH ANY DAMAGE TO PLAN NORTH WALL OF
21. REPLACE SAFETY LABELS AT ALL FLOOR ELEVATIONS.
AND REQUIREMENTS.
SEE SPECIFICATION 14 21 23 FOR ADDITIONAL INFORMATION 20.
SUPPLY AND INSTALL NEW GOVERNOR TENSION WEIGHT.19.
REPLACE CAR AND COUNTERWEIGHT BUFFERS.18.
REPLACE EXISTING COUNTERWEIGHT.17.
SUPPLY AND INSTALL NEW TRAVELING CABLE.16.
ENCLOSURE (FLOORS, WALLS, AND CEILING).
SUPPLY AND INSTALL NEW SAFETIES, TOE GUARD, AND INTERIOR CAB 15.
SUPPLY AND INSTALL NEW DOOR PROTECTION SYSTEM.14.
JAMB BRAILLE.
HALL STATIONS, HALL PLO AT LEVEL 1 (ELEV 1273.0), AND PROVIDE
LIMITED TO MAIN CAR STATION, CAR DIRECTION LANTERNS,
PROVIDE NEW SIGNAL FEATURES INCLUDING BUT NOT13.
NOT USED.12.
NOT USED.11.
RETAIN EXISTING ELEVATOR CAR PLATFORM. 10.
SUPPLY AND INSTALL NEW DOOR OPERATORS.9.
ROPE GRIPPER, AND ADAPTER BEAMS.
SUPPLY AND INSTALL NEW HOIST MACHINE, MOTOR, ENCODER, BRAKE8.
SUPPLY AND INSTALL NEW HOIST ROPES.7.
SUPPLY AND INSTALL NEW GOVERNOR ROPE.6.
SUPPLY AND INSTALL NEW GOVERNOR.5.
SUPPLY AND INSTALL NEW ELEVATOR CONTROLLER/DRIVE.4.
DOOR ROLLERS AND DOOR MECHANISMS TO LIKE NEW QUALITY - TYP. ALL FLOORS.
FULLY REPAIR AND REFURBISH EXISTING ELEVATOR LOBBY 3.
NOT USED.1.
GENERAL NOTES:
M18
KEYPLAN
1"=40'SCALE:
-0
-2
A M
G
E N
E R
A L
R E
V
IS
IO
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A D
V E
R T
IS
E
M E
N T
GUIDE RAILS TO REMAIN
EXISTING STEEL
1-100 1-100
SHAFT
ELEVATOR
UNITS
AND STRUCTURAL CLAY
HOISTWAY - CONCRETE
EXISTING ELEVATOR
1-101
LOBBY
ELEVATOR
1-101
B5
B9
A-130 A-300
A-130 A-300
B14
A-130 A-300
A-301
B6
ANY EXISTING HOLES
MUST BE SIZED TO COVER
- BACK PLATE
CALL BUTTON ASSEMBLY
REPLACE WITH A NEW
BUTTON ASSEMBLY AND
REMOVE EXISTING CALL
ANY EXISTING HOLES
SIZED TO COVER
BACK PLATES MUST BE
ASSEMBLIES -
NEW FLOOR INDICATOR
REPLACE WITH
ASSEMBLIES AND
FLOOR INDICATOR
REMOVE EXISTING
EXISTING HOLES
COVER ANY
MUST BE SIZED TO
SIGN - BACK PLATE
REPLACE ELEVATOR
MAINTENANCE ASSEMBLY
FUNCTIONALITY OF EXISTING
PROTECT AND MAINTAIN
CORNER
PAINT FROM CORNER TO
UP TO TRIM, EAST-WEST
PAINT FROM TOP OF TILE
DURING PAINTING
- PROTECT FLOOR
1 2 3 4 5 6 7 8 9 10
A
B
D
F
G
H
J
1 2 3 4 5 7
8 9 10
2A 4A
J
H
GA
A
B
D
F
G
GUIDE RAILS TO REMAIN
EXISTING STEEL
1-100 1-100
SHAFT
ELEVATOR
UNITS
AND STRUCTURAL CLAY
HOISTWAY - CONCRETE
EXISTING ELEVATOR
1-101
LOBBY
ELEVATOR
1-101
B5
B9
A-130 A-300
A-130 A-300
B14
A-130 A-300
A-301
B6
ANY EXISTING HOLES
MUST BE SIZED TO COVER
- BACK PLATE
CALL BUTTON ASSEMBLY
REPLACE WITH A NEW
BUTTON ASSEMBLY AND
REMOVE EXISTING CALL
ANY EXISTING HOLES
SIZED TO COVER
BACK PLATES MUST BE
ASSEMBLIES -
NEW FLOOR INDICATOR
REPLACE WITH
ASSEMBLIES AND
FLOOR INDICATOR
REMOVE EXISTING
EXISTING HOLES
COVER ANY
MUST BE SIZED TO
SIGN - BACK PLATE
REPLACE ELEVATOR
MAINTENANCE ASSEMBLY
FUNCTIONALITY OF EXISTING
PROTECT AND MAINTAIN
CORNER
PAINT FROM CORNER TO
UP TO TRIM, EAST-WEST
PAINT FROM TOP OF TILE
DURING PAINTING
- PROTECT FLOOR
A N
S
P L
A C
E M
E N
T
P O
W E
R H
O U
S E
P A
S S
E N
G E
R E
L E
V A
T O
R
F O
R T
R A
N D
A L
L D
A M
S
O U
T H
D A
K O
T A
W F
R
N O
V E
M B
E R
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
E
N U
M B
E R
F
IL
E N
A M
E
B
G O
R
E V
A T
IO
N
.0
F L
O O
R P
L A
N
A-130
A F
O R
D
B
G O
R
A
-1
.d
F
O
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
SCALE: 1/4" = 1'-0"
0 4'4' 2'
DOORS ARE TO BE PAINTED AND FRAME IS TO REMAIN UNPAINTED.
COLORS. - TYPICAL ALL FLOORS OTHER THAN LEVEL 1 (ELEV 1273.0) WHERE
LOBBY/HOISTWAY DOORS AND FRAMES. MATCH EXISTING
SURFACE PREPARE AND PAINT EXISTING ELEVATOR 2.
THAT IS NOT ARCHITECTURAL IN NATURE.
23. SEE ALL OTHER TECHNICAL DISCIPLINES' DRAWINGS FOR ALL WORK
1244, 1258, 1273, AND 1291.
ELEVATOR LOBBY, REPAINT TO MATCH EXISTING. - TYPICAL AT ELEVATIONS
22. REPAIR AND REFINISH ANY DAMAGE TO PLAN NORTH WALL OF
21. REPLACE SAFETY LABELS AT ALL FLOOR ELEVATIONS.
AND REQUIREMENTS.
SEE SPECIFICATION 14 21 23 FOR ADDITIONAL INFORMATION 20.
SUPPLY AND INSTALL NEW GOVERNOR TENSION WEIGHT.19.
REPLACE CAR AND COUNTERWEIGHT BUFFERS.18.
REPLACE EXISTING COUNTERWEIGHT.17.
SUPPLY AND INSTALL NEW TRAVELING CABLE.16.
ENCLOSURE (FLOOR, WALLS, AND CEILING).
SUPPLY AND INSTALL NEW SAFETIES, TOE GUARD, AND INTERIOR CAB 15.
SUPPLY AND INSTALL NEW DOOR PROTECTION SYSTEM.14.
JAMB BRAILLE.
HALL STATIONS, HALL PL AT LEVEL 1 (ELEV 1273.0), AND PROVIDE
LIMITED TO MAIN CAR STATION, CAR DIRECTION LANTERNS,
PROVIDE NEW SIGNAL FEATURES INCLUDING BUT NOT13.
NOT USED.12.
NOT USED.11.
RETAIN EXISTING ELEVATOR CAR PLATFORM. 10.
SUPPLY AND INSTALL NEW DOOR OPERATORS.9.
ROPE GRIPPER, AND ADAPTER BEAMS.
SUPPLY AND INSTALL NEW HOIST MACHINE, MOTOR, ENCODER, BRAKE8.
SUPPLY AND INSTALL NEW HOIST ROPES.7.
SUPPLY AND INSTALL NEW GOVERNOR ROPE.6.
SUPPLY AND INSTALL NEW GOVERNOR.5.
SUPPLY AND INSTALL NEW ELEVATOR CONTROLLER/DRIVE.4.
DOOR ROLLERS AND DOOR MECHANISMS TO LIKE NEW QUALITY - TYP. ALL FLOORS.
FULLY REPAIR AND REFURBISH EXISTING ELEVATOR LOBBY 3.
NOT USED.1.
GENERAL NOTES:
C5
FLOOR PLAN - ELEVATION 1273.0
1/4"=1'-0"SCALE:
M16
KEY PLAN
1"=40'SCALE:
-0
-2
A M
G
E N
E R
A L
R E
V
IS
IO
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A D
V E
R T
IS
E
M E
N T
B14
A-140 A-300
UNITS
AND STRUCTURAL CLAY
HOISTWAY - CONCRETE
EXISTING ELEVATOR
REMAIN
GUIDE RAILS TO
EXISTING STEEL
2-100 2-100
SHAFT
ELEVATOR
2-101
LOBBY
ELEVATOR
2-101
B5
B9
A-140 A-300
A-300A-140
A-301
B6
PLATE TO MATCH ENTRY
- PAINT ADDITIONAL MISC.
ANY EXISTING HOLES
MUST BE SIZED TO COVER
ASSEMBLIES - BACK PLATES
NEW FLOOR INDICATOR
REPLACE WITH
ASSEMBLIES AND
FLOOR INDICATOR
REMOVE EXISTING
ANY EXISTING HOLES
MUST BE SIZED TO COVER
- BACK PLATE
CALL BUTTON ASSEMBLY
REPLACE WITH A NEW
BUTTON ASSEMBLY AND
REMOVE EXISTING CALL
ANY EXISTING HOLES
BE SIZED TO COVER
BACK PLATE MUST
REPLACE "ELEVATOR" SIGN -
ASSEMBLY
EXISTING MAINTENANCE
FUNCTIONALITY OF
PROTECT AND MAINTAIN
PAINTING
FLOOR DURING
FLOOR - PROTECT
AND FROM CEILING TO
CORNER TO CORNER
PAINT WALL FROM
1 2 3 4 5 6 7 8 9 10
A
B
D
F
G
H
J
1 2 3 4 5 7
8 9 10
2A 4A
J
H
GA
A
B
D
F
G
B14
A-140 A-300
UNITS
AND STRUCTURAL CLAY
HOISTWAY - CONCRETE
EXISTING ELEVATOR
REMAIN
GUIDE RAILS TO
EXISTING STEEL
2-100 2-100
SHAFT
ELEVATOR
2-101
LOBBY
ELEVATOR
2-101
B5
B9
A-140 A-300
A-300A-140
A-301
B6
PLATE TO MATCH ENTRY
- PAINT ADDITIONAL MISC.
ANY EXISTING HOLES
MUST BE SIZED TO COVER
ASSEMBLIES - BACK PLATES
NEW FLOOR INDICATOR
REPLACE WITH
ASSEMBLIES AND
FLOOR INDICATOR
REMOVE EXISTING
ANY EXISTING HOLES
MUST BE SIZED TO COVER
- BACK PLATE
CALL BUTTON ASSEMBLY
REPLACE WITH A NEW
BUTTON ASSEMBLY AND
REMOVE EXISTING CALL
ANY EXISTING HOLES
BE SIZED TO COVER
BACK PLATE MUST
REPLACE "ELEVATOR" SIGN -
ASSEMBLY
EXISTING MAINTENANCE
FUNCTIONALITY OF
PROTECT AND MAINTAIN
PAINTING
FLOOR DURING
FLOOR - PROTECT
AND FROM CEILING TO
CORNER TO CORNER
PAINT WALL FROM
A N
S
P L
A C
E M
E N
T
P O
W E
R H
O U
S E
P A
S S
E N
G E
R E
L E
V A
T O
R
F O
R T
R A
N D
A L
L D
A M
S
O U
T H
D A
K O
T A
W F
R
N O
V E
M B
E R
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
E
N U
M B
E R
F
IL
E N
A M
E
B
G O
R
E V
A T
IO
N
.0
F L
O O
R P
L A
N
A-140
A F
O R
D
B
G O
R
A
-1
.d
F
O
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
SCALE: 1/4" = 1'-0"
0 4'4' 2'
DOORS ARE TO BE PAINTED AND FRAME IS TO REMAIN UNPAINTED.
COLORS. - TYPICAL ALL FLOORS OTHER THAN LEVEL 1 (ELEV 1273.0) WHERE
LOBBY/HOISTWAY DOORS AND FRAMES. MATCH EXISTING
SURFACE PREPARE AND PAINT EXISTING ELEVATOR 2.
THAT IS NOT ARCHITECTURAL IN NATURE.
23. SEE ALL OTHER TECHNICAL DISCIPLINES' DRAWINGS FOR ALL WORK
1273, AND 1291.
ELEVATOR LOBBY, REPAINT TO MATCH EXISTING. TYPICAL AT ELEVATIONS 1244, 1258,
22. REPAIR AND REFINISH ANY DAMAGE TO PLAN NORTH WALL OF
21. REPLACE SAFETY LABELS AT ALL FLOOR ELEVATIONS.
AND REQUIREMENTS.
SEE SPECIFICATION 14 21 23 FOR ADDITIONAL INFORMATION 20.
SUPPLY AND INSTALL NEW GOVERNOR TENSION WEIGHT.19.
REPLACE CAR AND COUNTERWEIGHT BUFFERS.18.
REPLACE EXISTING COUNTERWEIGHT.17.
SUPPLY AND INSTALL NEW TRAVELING CABLE.16.
ENCLOSURE (FLOORS, WALLS, AND CEILING).
SUPPLY AND INSTALL NEW SAFETIES, TOE GUARD, AND INTERIOR CAB 15.
SUPPLY AND INSTALL NEW DOOR PROTECTION SYSTEM.14.
JAMB BRAILLE.
HALL STATIONS, HALL PL AT LEVEL 1 (ELEV 1273.0), AND PROVIDE
LIMITED TO MAIN CAR STATION, CAR DIRECTION LANTERNS,
PROVIDE NEW SIGNAL FEATURES INCLUDING BUT NOT13.
NOT USED.12.
NOT USED.11.
RETAIN EXISTING ELEVATOR CAR PLATFORM. 10.
SUPPLY AND INSTALL NEW DOOR OPERATORS.9.
ROPE GRIPPER, AND ADAPTER BEAMS.
SUPPLY AND INSTALL NEW HOIST MACHINE, MOTOR, ENCODER, BRAKE8.
SUPPLY AND INSTALL NEW HOIST ROPES.7.
SUPPLY AND INSTALL NEW GOVERNOR ROPE.6.
SUPPLY AND INSTALL NEW GOVERNOR.5.
SUPPLY AND INSTALL NEW ELEVATOR CONTROLLER/DRIVE.4.
DOOR ROLLERS AND DOOR MECHANISMS TO LIKE NEW QUALITY - TYP. ALL FLOORS.
FULLY REPAIR AND REFURBISH EXISTING ELEVATOR LOBBY 3.
NOT USED.1.
GENERAL NOTES:
C5
FLOOR PLAN - ELEVATION 1291.0
1/4"=1'-0"SCALE:
M16
KEY PLAN
1"=40'SCALE:
A M
G
E N
E R
A L
R E
V
IS
IO
N
-0
-2
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A D
V E
R T
IS
E
M E
N T
ROOM ELEVATION 1307.0 - DEMOLITION
EXISTING FLOOR PLAN - ELEVATOR MACHINE
4 65
F
G
D
B
A
4 65
B
A
D
F
G
ROOM ELEVATION 1307.0 -
FLOOR PLAN - ELEVATOR MACHINE
MACHINERY
EXISTING ELEVATOR
JOINT
CONSTRUCTION
EXISTING
GRATING
EXISTING
CONC WALL
EXISTING
CLAY UNITS
EXISTING STRUCTURAL
AND GUARDRAILS
EXISTING STAIRS
LOUVERS
ALUMINUM
EXISTING
OVERLOADING
AND PROTECT FROM
CONTRACTOR TO AVOID
CAPACITY UNKNOWN,
EXISTING HATCH COVER -
AND GUARDRAILS
EXISTING STAIRS
CATWALK
EXISTING
LADDER
EXISTING
AT ELEVATION 1318.17
EXISTING LANDING
STACK
INCINERATOR
EXISTING
- TYP.
DUCT OPENING
EXISTING
BASES - TYP.
EXISTING FAN
DUCT OPENING
EXISTING
LOUVER
ALUMINUM
EXISTING
JOINT
CONSTRUCTION
EXISTING
7'-11"10'-8"
EM1
MACHINE ROOM
ELEVATOR
MOVING INTO POSITION
TO BE ACCESSED WHILE
HATCHES, AND STAIRWELLS
SIZE WITH ALL DOORS,
EQUIPMENT - COORDINATE
NEW ELEVATOR
REFERENCE UL DESIGN U437
TO ENSURE 2-HOUR FIRE RATING
SHAFTWALL CORE BD. -
AND ONE LAYER OF 1" GYP
OF 5/8" TYPE "X" GWB
SET BETWEEN TWO LAYERS
(OR AS REQUIRED FOR SPAN)
WITH STEEL STUDS @ 24" O.C.
6" SHAFTWALL ASSEMBLY
AND FRAME ASSEMBLY
90 MINUTE F.R DOOR
INTAKE CEILING
FRESH AIR
EXISTING
OUTLINE OF
REMOVED
CONDUIT WAS
FLOOR WHERE
IN EXIST. CONC.
PATCH OPENING
BELOW
EXISTING ROOF
STR. & MECH.
DUCTWORK- SEE
SYSTEM
PRESSURIZATION
HOISTWAY
OPENING FOR
ENLARGED FLOOR
MECH. AND STR.
NEW DUCT - SEE
CONC. FLOOR FOR
OPENING IN EXIST.
NEW +/- 1'-0" X 1'-0"
E M
FLOOR - PATCH
OPENING IN
EXISTING 4"X4"
SPECIFICATIONS
IN ACCORDANCE TO THE
APPLY PAINT AND TEXTURE
1 2 3 4 5 6 7 8 9 10
A
B
D
F
G
H
J
1 2 3 4 5 72A 4A
A
B
D
F
G
11 12 13 14 15 16 17 18 2019 21 22 23 24 25 26 27 28 29 30 32 33 34 3531 37 38 39 4036 42 43 44 4541 47 48 49 5046 51
GA
ON C/A-300 AND M-501.
METAL DUCT AS SHOWN
CAP. INSTALL NEW SHEET
CURB AND SHEET METAL
OPENING WITH ROOF
EXISTING +/- 2'-0" X 1'-6"
WORK
PROTECT DURING
ROOF ASSEMBLY-
EXISTING EPDM
S L
O P
E
WORK
PROTECT DURING
ROOF BELOW -
EXISTING EPDM
EXPANSION JOINT
EXISTING BUILDING
A N
S
P L
A C
E M
E N
T
P O
W E
R H
O U
S E
P A
S S
E N
G E
R E
L E
V A
T O
R
F O
R T
R A
N D
A L
L D
A M
S
O U
T H
D A
K O
T A
W F
R
N O
V E
M B
E R
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
E
N U
M B
E R
F
IL
E N
A M
E
B
G O
R
E V
A T
IO
N
.0
F L
O O
R P
L A
N
A-150
A F
O R
D
B
G O
R
A
-1
.d
F
O
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
M15
KEY PLAN
1"=80'SCALE:
THAT IS NOT ARCHITECTURAL IN NATURE.
23. SEE ALL OTHER TECHNICAL DISCIPLINES' DRAWINGS FOR ALL WORK
1273, AND 1291.
ELEVATOR LOBBY, REPAINT TO MATCH EXISTING. TYPICAL AT ELEVATIONS 1244, 1258,
22. REPAIR AND REFINISH ANY DAMAGE TO PLAN NORTH WALL OF
21. REPLACE SAFETY LABELS AT ALL FLOOR ELEVATIONS.
AND REQUIREMENTS.
SEE SPECIFICATION 14 21 23 FOR ADDITIONAL INFORMATION 20.
SUPPLY AND INSTALL NEW GOVERNOR TENSION WEIGHT.19.
REPLACE CAR AND COUNTERWEIGHT BUFFERS.18.
REPLACE EXISTING COUNTERWEIGHT.17.
SUPPLY AND INSTALL NEW TRAVELING CABLE.16.
NOT USED.15.
SUPPLY AND INSTALL NEW DOOR PROTECTION SYSTEM.14.
NOT USED.13.
NOT USED.12.
NOT USED.11.
NOT USED.10.
NOT USED.9.
ROPE GRIPPER, AND ADAPTER BEAMS.
SUPPLY AND INSTALL NEW HOIST MACHINE, MOTOR, ENCODER, BRAKE8.
SUPPLY AND INSTALL NEW HOIST ROPES.7.
SUPPLY AND INSTALL NEW GOVERNOR ROPE.6.
SUPPLY AND INSTALL NEW GOVERNOR.5.
SUPPLY AND INSTALL NEW ELEVATOR CONTROLLER/DRIVE.4.
NOT USED.3.
NOT USED. 2.
NOT USED.1.
GENERAL NOTES:
A
M
G E
N E
R A
L R
E V
IS
IO
N S
-0
-2
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A D
V E
R T
IS
E
M E
N T
1 2 3 4 5 6 7
A
B
D
F
G
H
J
1 2 3 4 5 72A 4A
GA
ON C/A-300 AND M-501.
METAL DUCT AS SHOWN
CAP. INSTALL NEW SHEET
CURB AND SHEET METAL
OPENING WITH ROOF
EXISTING +/- 2'-0" X 1'-6"
WORK
PROTECT DURING
ROOF ASSEMBLY-
EXISTING EPDM
S L
O P
E
WORK
PROTECT DURING
ROOF BELOW -
EXISTING EPDM
EXPANSION JOINT
EXISTING BUILDING
1 2 3 4 5 6 7 8 9 10
A
B
D
F
G
H
J
1 2 3 4 5 72A 4A
A
B
D
F
G
11 12 13 14 15 16 17 18 2019 21 22 23 24 25 26 27 28 29 30 32 33 34 3531 37 38 39 4036 42 43 44 4541 47 48 49 5046 51
GA
ON C/A-300 AND M-501.
METAL DUCT AS SHOWN
CAP. INSTALL NEW SHEET
CURB AND SHEET METAL
OPENING WITH ROOF
EXISTING +/- 2'-0" X 1'-6"
WORK
PROTECT DURING
ROOF ASSEMBLY-
EXISTING EPDM
S L
O P
E
WORK
PROTECT DURING
ROOF BELOW -
EXISTING EPDM
EXPANSION JOINT
EXISTING BUILDING
A N
S
P L
A C
E M
E N
T
P O
W E
R H
O U
S E
P A
S S
E N
G E
R E
L E
V A
T O
R
F O
R T
R A
N D
A L
L D
A M
S
O U
T H
D A
K O
T A
W F
R
N O
V E
M B
E R
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
E
N U
M B
E R
F
IL
E N
A M
E
B
G O
R
R T
IA
L
R O
O F
P L
A N
A-170
A F
O R
D
B
G O
R
A
-1
.d
F
O
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
A3
PARTIAL ROOF PLAN
SCALE: 1/32"= 1'-0"
M15
KEY PLAN
1"=80'SCALE:
SCALE: 1/32" = 1'-0"
32' 16' 32'
-0
-2
A
M
S H
E E
T R
E
IS
S U
E D
L
E V
E L
T O
N E
A D
J U
S T
M E
N T
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A D
V E
R T
IS
E
M E
N T
ELEV. 1244.0
LEVEL B
FIN. Fl.
ELEV. 1258.0
LEVEL A
FIN. FL.
ELEV. 1273.0
LEVEL 1
FIN. FL.
ELEV. 1291.0
LEVEL 2
FIN FLOOR
ELEV. 1307.0
MACH. RM
FIN. FL - ELEV. ROOF
EXIST.
EM1
MACHINE ROOM
ELEVATOR
4 5 6
4A
LOBBY
ELEVATOR
B-101
LOBBY
ELEVATOR
A-101
LOBBY
ELEVATOR
1-101
LOBBY
ELEVATOR
2-101
ELEV. 1238.17
B.O ELEV PIT
FIN. Fl.
B13
A-301A-301
1-101
ASSEMBLY - TYP.
CALL BUTTON
NEW RECESSED
1273 ONLY
OCCURS - TYP. AT
ANY DAMAGE THAT
CONSTRUCTION, REPAIR
- PROTECT DURING
TILE WAINSCOT
EXISTING CERAMIC
TO MATCH EXIST.
DOORS AND FRAMES
ELEVATOR SHAFT
PAINT EXISTING
DEFINED ON OTHER SHEETS
- TYP. AT ALL ELEVATIONS,
TO MATCH EXIST.
PLASTER WALLS
PAINT EXISTING
AS SHOWN IN A/A-301
AT 1273, ALL OTHERS TO SIDE
ASSEMBLY - OVER DOOR
NEW FLOOR INDICATOR
CALL ASSEMBLY
EXISTING MAINTENANCE
FUNCTIONALITY OF
AND MAINTAIN
LABELS, PROTECT
REPLACE SAFETY
OF ENTRY
INTERIOR FACES
LABELS ON BOTH
NEW FLOOR
- SEE ELEC.
SMOKE DETECTORS
REPLACE ALL
NEW "ELEVATOR" SIGN
A N
S
P L
A C
E M
E N
T
P O
W E
R H
O U
S E
P A
S S
E N
G E
R E
L E
V A
T O
R
F O
R T
R A
N D
A L
L D
A M
S
O U
T H
D A
K O
T A
W F
R
N O
V E
M B
E R
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
E
N U
M B
E R
F
IL
E N
A M
E
B
G O
R
E V
A T
O R
E L
E V
A T
IO
N
S
A-301
A F
O R
D
B
G O
R
A
-3
.d
F
O
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
B6
A-301 A-301
ELEVATOR LOBBY ELEVATIONS B13
A-301 A-301
TYPICAL ELEVATOR LOBBY ELEVATION
@ 1244, 1258, 1273, AND 1291
A
M
G E
N E
R A
L R
E V
IS
IO
N S
-0
-2
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A D
V E
R T
IS
E
M E
N T
A N
S
P L
A C
E M
E N
T
P O
W E
R H
O U
S E
P A
S S
E N
G E
R E
L E
V A
T O
R
F O
R T
R A
N D
A L
L D
A M
S
O U
T H
D A
K O
T A
W F
R
N O
V E
M B
E R
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
E
N U
M B
E R
F
IL
E N
A M
E
J
S W
E R
C Z
C H
A N
IC
A
L E
Q U
IP
M
E N
T S
C H
E D
U L
E S
A N
D C
O N
T R
O L
S
M-601
K
P A
R K
J
S W
E R
C Z
M
-6
.d
P A
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
P
R O
D U
C T
IO
N
D A
T A
REMARKS
REMARKS:
DRIVE TYPE
BELT
MANUFACTURERMARK MODELTYPE (CFM)
AIR FLOW
O)
PRESS. (IN. H
EXT. STAT.
LEVELS (SONES)
MAX. SOUND
DIRECT
FAN SCHEDULE
SF-1 3100 0.5"INLINE X--- - - 1,2,3,4,5
PROVIDE OSHA FAN GUARD AT INLET, COMBINATION FIRE /SMOKE DAMPER ON FAN DISCHARGE SIDE WALL.
IN ACCORDANCE WITH IBC 2021, ASME 17.1 (2022), AND APPLICABLE NFPA STANDARDS.
PROVIDE ELEVATOR HOISTWAY PRESSURIZATION FAN SYSTEM AND ALL APPARATUS REQUIRED TO MEET THE FUNCTIONAL REQUIREMENTS OF THE SMOKE CONTROL SYSTEM
FAN MOTOR SHALL BE PROVIDED WITH VARIABLE FREQUENCY DRIVE (VFD).
PROVIDE MESHED SCREEN AND MOTORIZED DAMPER (NORMALLY CLOSED) AT AIR INTAKE PENTHOUSE.
PROVIDE SMOKE DETECTOR AT FAN DISCHARGE AIR STREAM WHICH WILL AUTOMATICALLY SHUTDOWN THE FAN SYSTEM WHEN SMOKE IS DETECTED WITHIN THE SYSTEM.
MOUNT UNIT ACCORDING TO MANUFACTURER'S RECOMMENDATIONS INCLUDING NECESSARY VIBRATION ISOLATORS .
WITH IBC 2021.
IN.WC AND A MAXIMUM POSITIVE PRESSURE OF 0.25 IN.WC WITH RESPECT TO ADJACENT OCCUPIED SPACE ON ALL FLOORS IN ACCORDANCE THE SYSTEM FAN (SF-1) AND ITS CONTROL SHALL PRESSURIZE THE ELEVATOR HOISTWAY TO MAINTAIN A MINIMUM POSITIVE PRESSURE OF 0.10
DURING THE FIRE EVENT.
SF-1 SPEED SHALL BE CONTROLLED BY THE ASSOCIATED VFD TO POSITIVELY PRESSURIZE THE HOISTWAY RELATIVE TO THE FIRE FLOOR
SYSTEM AND/OR THE ELEVATOR LANDING AREA SMOKE DETECTORS.
ELEVATOR HOISTWAY PRESSURIZATION SYSTEM FAN, SF-1 SHALL BE ACTIVATED UPON ACTIVATION OF EITHER THE BUILDING FIRE ALARM
COMPLETE FUNCTIONAL ELEVATOR HOISTWAY PRESSURIZATION SYSTEM PER CODE REQUIREMENTS.
RELATED CONTROL DEVICES AND DETAILED CONTROL SCHEMATIC INCLUDING POINTS SUMMARY (INPUT/OUTPUT) ON SHOP DRAWINGS FOR DIAGRAM ON SHOP DRAWINGS PER SPECIFICATION SECTION 14 21 23. CONTRACTOR SHALL CLEARLY INDICATE PRESSURIZATION SYSTEM PER IBC 2021. CONTRACTOR SHALL DETERMINE THE SUITABLE LOCATIONS FOR DP SENSORS, WIRING ROUTE, AND PRESENT SCHEMATIC LANDING AREA ON EACH FLOOR TO CONTROL SF-1 FAN SPEED TO MAINTAIN ABOVE REFERENCED DIFFERENTIAL PRESSURE RANGE REQUIRED NOTE: CONTRACTOR SHALL PROVIDE ALL NECESSARY DIFFERENTIAL PRESSURE (DP) SENSORS AND WIRING IN HOISTWAY AND ELEVATOR
SEQUENCE OF OPERATION (SF-1):
1.
2.
3.
1.
EF-1 1600 0.5"WALL MOUNT AXIAL X--- - - 1,6
ACTIVATION OF SIGNAL.
LOUVER SHALL OPEN / CLOSE ACCORDINGLY. SMOKE ALARM SIGNAL SHALL OVERRIDE DAMPER POSITION COMMAND AND CLOSE DAMPER UPON 80 F. WHEN EF-1 IS COMMANDED TO OPERATE/STOP, BOTH COMBINATION FIRE/SMOKE DAMPERS IN AIR INTAKE LOUVER AND THE EXHAUST AIR EF-1 SHALL BE ENERGIZED WHENEVER ROOM TEMPERATURE RISE ABOVE 85 F. FAN SHALL STOP WHEN THE ROOM TEMPERATURE FALLS BELOW
SEQUENCE OF OPERATION (EF-1):
1.
REMARKSMANUFACTURERMARK MODELLOCATION (CFM)
AIR FLOW
CAPACITY
HEATING
(VOLTS / PH)
ELECTRICAL
TYPE
MOUNTING
ELECTRIC UNIT HEATER SCHEDULE
EUH-1 400 3 KWELEVATOR MR WALL MOUNTED - - 1208 /1
REMARKS:
PROVIDE UNIT WITH INTEGRAL THERMOSTAT CONTROL1.
EUH-1 SHALL BE ENERGIZED TO MAINTAIN ROOM TEMPERATURE 70F. UNIT SHALL OPERATE BASED ON INTEGRAL THERMOSTAT CONTROL.
SEQUENCE OF OPERATION (EUH-1)
1.
2.
3.
4.
5.
6.
A M
G
E N
E R
A L
R E
V
IS
IO
N
-0
-2
| FR00108G-001 |
| FR00108A-110 |
| FR00108A-120 |
| FR00108A-130 |
| FR00108A-140 |
| FR00108A-150 |
| FR00108A-170 |
| FR00108A-301 |
| FR00108M-601 |