Questions and Answers FT Hood Tank Inspections.docx

DOCX document 15 KB Posted

Attached to
Fort Hood Tank Inspection
Solicitation number
W9128F25QA101
Issued by

About this file

This document is a Questions and Answers file for a Fort Hood Tank Inspection contract opportunity. The file provides critical technical details about tank inspection requirements, including specifications for three facilities (88071, 88045, and 88072). Key details include multiple tank transfers, with transfer quantities ranging from 3,500 to 5,000 gallons, and specifications for handling fuel/sludge or residual product not exceeding 100 gallons. The document confirms internal floating roof details for Tank 211, indicates a minimum of two mobilizations will be required for inspections, and provides information about tank proximity and transfer logistics, with tanks 310 and 311 being approximately 100 feet apart and Tank 211 potentially being transferred to a JAA tank with an estimated 250-350 foot transfer distance.

The related federal contract opportunity involves the Department of the Army Corps of Engineers Engineering District Omaha, with Solicitation Number W9128F25QA101. The primary scope includes conducting three API 653 internal inspections across specified facilities, one API 653 external inspection, and wiper seal replacement at Ft. Hood, Texas, in compliance with applicable laws, standards, federal regulations, and state and local guidelines. The solicitation requires adherence to specific inspection and transfer protocols outlined in the accompanying documentation.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Questions and Answers

UNCLASSIFIED

1. The transfer quantities in attachment B do not match the quantities in the PWS, Section 4.1.11 for tanks 310 and 311.

Transfer fuel to adjacent tank not to exceed 5000 gallons and dispose of fuel/sludge or residual product not to exceed 100 gallons for facility 88071.

Transfer fuel to adjacent tank not to exceed 3500 gallons and dispose of fuel/sludge or residual product not to exceed 100 gallons for facility 88072.

Transfer fuel to adjacent tank not to exceed 3500 gallons and dispose of fuel/sludge or residual product not to exceed 100 gallons for facility 88045.

1. Confirming that Tank 211 does have an internal floating roof as the 2008 internal inspection shows none but the 2016 shows it has one.

1. If yes, what type of IFR?

0. Full-Contact Internal Covers ("Honeycomb" Type) They are in direct contact with the liquid, eliminating the vapor space. They are made up of honeycomb sandwich panels and are made of aluminum or stainless steel.

1. If yes, what is the leg setting for the IFR?

1. I believe around 6 feet.

1. N/A

1. Are tanks 310, 311 and 211 (internal inspections) to be completed on a single mobilization or multiple?

3. If multiple, how many mobilizations are expected/required?

A minimum of two mobilizations will be required for these inspections.

1. N/A

1. Where is the fuel from Tanks 310, 311 and 211 being transferred into?

5. Tank 310 and 311 are approximately 100 feet apart. One of these tanks will have to be transferred into the other. Only two DS2 Tanks we have.

5. Tank 211 can be transferred until empty into one of the other two JAA Tanks. Estimating 250 to 350 foot to nearest JAA tank if it has to be done the hard way.

5. How what is the estimated distance between the tanks that we will being transferred to?