20210902_W9128F21R0070 AM0005 - Drawings.pdf

PDF 3 MB Posted

Attached to
CNS Consolidated Helo/TRF Ops/AMU and Alert Facility, FE Warren AFB, WY
Solicitation number
W9128F21R0070
Issued by

About this file

This document package includes construction drawings and specifications for Solicitation W9128F21R0070 to construct a Helo/TRF Ops/AMU and Alert Facility at FE Warren Air Force Base in Wyoming. The project involves construction of a new facility including site utilities, a crash/fire rescue facility as an optional bid item. The Army Corps of Engineers Engineering District Omaha is the contracting agency. The drawings provide column schedules, plumbing schedules including fixture details and water heater specifications, mechanical details such as air handling unit specifications, and specifications for items including trench drains. The solicitation response date is not provided.

View the file

Other files

Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LEVEL 1 LEVEL 1

100' - 0" 100' - 0"

Column Locations A-8 A-12 A-14 A-15 B-16 B-18 B-19 B-21 C-22 C-24 C-26 C-28 C-29 C-31 C-32 C-34 C-37 C-37.9 C-39 C-42 D-4 D-6 E-4 E-6 E-16 E-21 F-4 F-6 G-22 G-32 G-42 H-1 H-2 H-4 H-6 H-8 H-14 H-15 H-16 H-21 J-16 J-18 J-19 J-21 J-22 J-24 J-26 J-28 J-29 J-31 J-32 J-34 J-36 J-37.9 J-39

LEVEL 1 LEVEL 1

100' - 0" 100' - 0"

Column Locations J-42 K-16 K-17 K-20 K-23 K-25 K-27 K-30 K-33 K-35 K-38 K-40 K-43 K-44 K-45 K-46 K-47 K-48 K-49 K-50 K-51 K-52 K-53 K.5-1 K.9-33 L-1 L-2 L-4 L-6 L-11 L-14 L-15 L.4-15 M-16 M-44 M-45 M-53 P-1 P-2 P-4 P-6 P-8.9 P-10 P-14 P-15 Q-16 Q-44 Q-45 Q-53 Q.7-33 R-16 R-17 R-33 R-43 R-44

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

H S

S

X X

/8

W X

W X

H S

S

X X

/8

H S

S

X X

/8

H S

S X

X

/8

H S

S

X X

/8

H S

S

X X

/8

H S

S

X X

/8

H S

S X

X

/8

W X

H S

S X

X

/8

H S

S X

X

/8

H S

S X

X

/8

W X

H S

S X

X

/8

W X

W X

W X

H S

S

X X

/8

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

H S

S

X X

/8

H S

S X

X

/8

H S

S X

X

/8

W X

H S

S

X X

/8

H S

S

X X

/8

H S

S

X X

/8

H S

S

X X

/8

H S

S

X X

/8

W X

W X

W X

H S

S

X X

/8

H S

S

X X

/8

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

TOP OF FOUNDATION (TYP-

REFER TO FOUNDATION

PLAN)

TOP OF FOUNDATION (TYP-

REFER TO FOUNDATION

PLAN)

ABRAHAM ABEL AVALOS

OF TEXASS

TATE

ALNOI

SS

E

F O

R P

ENG

IN

E E

R

NSEDECI

L 114070

US Army Corps of Engineers Omaha District ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

A F

-1

-0

-W F

R

M

A R

C H

C H

O F

F F

IL

E

N A

M E

O M

A H

A D

IS

T

R

IC

T

O M

A H

A

N E

B R

A S

K A

F Y

H

E L

O /T

R F

/M A

IN

T

E N

A N

C E

F A

C

IL

IT

Y

P R

O J E

C T

N U

M B

E R

G

H L

N A

F E

W A

R R

E N

A F

B

W Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t

F o rt

W o rt h

T X

READY-TO-ADVERTISE (RTA) DESIGN

TEXAS REGISTERED

ENGINEERING FIRM F-2966

S-600

C O

L U

M N

S C

H E

D U

L E

C V

A L L

E N

IL

L A

S .D

R A

S K

O V

IC

A .A

V A

L O

S

F E

-G

H L

N

A S

-6

A

M

R E

V

IS

IO

N

-0

-2

09/02/2021

LEVEL 1 LEVEL 1

100' - 0" 100' - 0"

Column Locations R-45 R-46 R-52 R-53 R.2-4 R.2-6 R.5-33 R.6-16 R.6-17 R.6-43 R.6-44 R.6-45 R.6-46 R.6-52 R.6-53 S-13 S-14 S-15 T-1 T-2 T-4 T-6 T-10 U-13 U-14 V-13 V-14 W-1' W-2' W-3' X-1 X-2 X-4 X-6 X-10 Y-1' Y-3' Z-1' Z-3' AA-1 AA-2 AA-4 AA-10 BB-1 BB-3 BB-5 BB-7 BB-9 CC-1' CC-3' DD-1 DD-7 DD-9 EE-1' EE-2'

LEVEL 1 LEVEL 1

100' - 0" 100' - 0"

Column Locations EE-3' FF-1 GG-1 HH-1 JJ-1 KK-1 LL-1 LL-7 LL-9 MM-1 MM-3 MM-5 MM-7 MM-9

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

H S

S X

X

/8

H S

S

X X

/8

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

3 W

X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

H S

S X

X

/8

W X

H S

S

X X

/8

W X

H S

S

X X

/8

H S

S

X X

/8

H S

S X

X

/8

H S

S X

X

/8

W X

W X

W X

H S

S X

X

/8

H S

S X

X

/8

W X

W X

W X

W X

W X

TOP OF FOUNDATION

(TYP- REFER TO

FOUNDATION PLAN)

TOP OF FOUNDATION

(TYP- REFER TO

FOUNDATION PLAN)

ABRAHAM ABEL AVALOS

OF TEXASS

TATE

ALNOI

SS

E

F O

R P

ENG

IN

E E

R

NSEDECI

L 114070

US Army Corps of Engineers Omaha District ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

A F

-1

-0

-W F

R

M

A R

C H

C H

O F

F F

IL

E

N A

M E

O M

A H

A D

IS

T

R

A H

A

N E

B R

A S

K A

F Y

H

E L

O /T

R F

/M A

IN

T

E N

A N

C E

F A

C

IL

IT

Y

P R

O J E

C T

N U

M B

E R

G

H L

N A

F E

W A

R R

E N

A F

B

W Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t

F o rt

W o rt h

T X

READY-TO-ADVERTISE (RTA) DESIGN

TEXAS REGISTERED

ENGINEERING FIRM F-2966

S-601

C O

L U

M N

S C

H E

D U

L E

C V

A L L

E N

IL

L A

S .D

R A

S K

O V

IC

A .A

V A

L O

S

F E

-G

H L

N

A S

-6

NOTE:

COLUMN SECTIONS FOR BID OPTION 2 ARE INDICATED

IN PLAN (RE: SB109)

A

M

R E

V

IS

IO

N

-0

-2

09/02/2021

FLOAT CONTROL VALVE

VALVES LOCKED IN OPEN

POSITION BY CHAIN

12" TEE TO FLOAT

CONTROL BYPASS

12" FROM

EXISTING

WATER

SUPPLY

SYSTEM

3/4" LINE TO PILOT

MOUNTED WITHIN

TANK ENCLOSURE

12" TANK FILL PIPE

12" TANK FILL PIPE

3/4" LINE TO PILOT

MOUNTED WITHIN

TANK ENCLOSURE

PLAN VIEW

ELEVATION VIEW

NORMALLY CLOSED 12"

CONTROL VALVE IN BYPASS

ACCESS LADDER

RE:A1/FP504

0.38'-0"

.2

"RE:A1/FP504

ACCESS HATCH

WITH LADDER

12" BYPASS

0.1

.1

4'-0"

SUPPORT COMPATIBLE

WITH PIPE TYPE

VAULT AND COVER SHALL BE H-20 RATED.

AIR GAP (MINIMUM TWO PIPE DIAMETERS)

RESERVOIR CELL

REFER TO STRUCTURAL DRAWINGS FOR

EXACT LOCATION AND DIMENSIONS OF

FIRE WATER STORAGE TANK

18 INCH

MINIMUM

FIRE PUMP COLUMN

AND SHAFT

FIRE PUMP BOWL

ASSEMBLY

NORMAL WATER LEVEL

WATER LEVEL FLOAT VALVE "ON"

WATER LEVEL FLOAT VALVE "OFF"

LW HW

HIGH WATER

LEVEL ALARM

LOW WATER

LEVEL ALARM

ADJUSTABLE STOP

COLLAR - LOW POINT

ADJUSTABLE STOP

COLLAR - HIGH POINT

STILLING WELL

FLOAT AT NORMAL

WATER LEVEL

FLOAT ROD

CONTROL LINES TO HYDRAULICALLY

OPERATE CONTROL VALVE

FLOAT ASSEMBLY WITH

MOUNTING BRACKET

CONCRETE

TANK WALL

COUNTERWEIGHT

US Army Corps of Engineers Omaha District ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

A F

-1

-0

-W F

R

M

A R

C H

C H

O F

F F

IL

E

N A

M E

O M

A H

A D

IS

T

R

A H

A

N E

B R

A S

K A

F Y

H

E L

O /T

R F

/M A

IN

T

E N

A N

C E

F A

C

IL

IT

Y

P R

O J E

C T

N U

M B

E R

G

H L

N A

F E

W A

R R

E N

A F

B

W Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t

F o rt

W o rt h

T X

READY-TO-ADVERTISE (RTA) DESIGN

FP504

F

IR

E S

U P

P R

E S

S

IO

N D

E T

A

IL

S

J S

H U

M A

K E

B B

U S

S

J B

E A

L S

F E

-G

H L

N

A F

P

12" = 1'-0"D1

FLOAT CONTROL VALVE VAULT DETAIL

NTSD6

WATER STORAGE TANK DETAIL

12" = 1'-0"A1

FLOAT CONTROL PILOT DETAIL

A

M

R E

V

IS

IO

N

S

-0

-2

BRODIE B. B. HEFLIN

OF TEXASS

TATE

ALNOI

SS

E

F O

R P

ENG

IN

E E

R

NSEDECI

L 106046

US Army Corps of Engineers Omaha District ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

A F

-1

-0

-W F

R

M

A R

C H

C H

O F

F F

IL

E

N A

M E

O M

A H

A D

IS

T

R

A H

A

N E

B R

A S

K A

F Y

H

E L

O /T

R F

/M A

IN

T

E N

A N

C E

F A

C

IL

IT

Y

P R

O J E

C T

N U

M B

E R

G

H L

N A

F E

W A

R R

E N

A F

B

W Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t

F o rt

W o rt h

T X

READY-TO-ADVERTISE (RTA) DESIGN

TEXAS REGISTERED

ENGINEERING FIRM F-2966

P-601

P L U

M B

IN

G

S C

H E

D U

L E

S

D K

E M

P

C R

O D

P B

A K

E R

F E

-G

H L

N

A P

-6

PLUMBING FIXTURE SCHEDULE

MARK FIXTURE DCW DHW TW WASTE VENT DESCRIPTION

WC-1 WATER CLOSET 1 1/4" - - 4" 2"

BOWL:

WALL HUNG, VITREOUS CHINA, SIPHON JET.

FLUSH VALVE:

MANUAL DIAPHRAGM TYPE, 1.28 GPF.

WC-2 WATER CLOSET 1 1/4" - - 4" 2"

BOWL:

ADA HEIGHT, WALL HUNG, VITREOUS CHINA, SIPHON JET.

FLUSH VALVE:

MANUAL DIAPHRAGM TYPE, 1.28 GPF.

WD-1

WALL DRAIN

BOX

- - - 3" 2"

WALL DRAIN BOX - SINGLE-WIDE WALL BOX. PROVIDE WITH DRAIN RECEPTOR FOR

CONDENSATE LINE FROM MECHANICAL EQUIPMENT. PROVIDE WITH ASSE 1072 TRAP SEAL.

PLUMBING FIXTURE SCHEDULE

MARK FIXTURE DCW DHW TW WASTE VENT DESCRIPTION

EEW-1

EMERGENCY

EYE WASHER

- - 1/2" 1-1/2" 1 1/2"

EYE/FACE WASH AND VALVE ASSEMBLY. PROVIDE WITH ALARM STATION INCLUDING HORN

AND STROB.

EEWS-1

EMERGENCY

FIXTURE

- - 1-1/2" - -

COMBINATION EMERGENCY SHOWER AND EYE/FACE WASH, FLOOR MOUNTED. PROVIDE WITH

ALARM STATION INCLUDING HORN AND STROBE.

EWC-1

WATER

COOLER

1/2" - - 2" 2"

ELECTRIC, REFRIGERATED, WALL HUNG, BI-LEVEL WITH BOTTLE FILLER AND INTEGRAL

WATER FILTER.

FD-1 FLOOR DRAIN - - - 3" 2" 3" FLOOR DRAIN WITH HEAVY DUTY STRAINER. PROVIDE WITH ASSE 1072 TRAP GUARD.

FD-2 FLOOR DRAIN - - - 4" 2" 4" FLOOR DRAIN WITH HEAVY DUTY STRAINER. PROVIDE WITH ASSE 1072 TRAP GUARD.

FS-1 FLOOR SINK - - - 3" - 3" FLOOR SINK WITH HEAVY DUTY STRAINER. PROVIDE WITH ASSE 1072 TRAP GUARD.

FS-3 FLOOR SINK - - - 4" 2" 4" FLOOR SINK WITH HEAVY DUTY STRAINER. PROVIDE WITH ASSE 1072 TRAP GUARD.

HB-1 HOSE BIB 3/4" - - - -

WALL CASING, PLATE AND FLANGE, FURNISHED WITH POLYCARBONATE WHEEL HANDLE AND

LOOSE TEE KEY, VACUUM BREAKER.

HD-1 HUB DRAIN - - - 3" 1 1/2"

8 5/8" DIAMETER DECK RECEPTOR DRAIN, DURA-COATED CAST IRON BODY WITH THREADED

OUTLET AND INTERNAL STRAINER.

PROVIDE ASSE 1072 BARRIER TYPE TRAP SEAL.

L-1 LAVATORY 1/2" 1/2" - 2" 2"

SINK:

WHITE VITREOUS CHINA, UNDER-COUNTER MOUNT.

FAUCET:

MANUAL WITH SINGLE LEVER HANDLE, CHROME PLATED, 0.5 GPM.

L-2 LAVATORY 1/2" 1/2" - 2" 2"

SINK:

WHITE VITREOUS CHINA, WALL MOUNT.

FAUCET:

MANUAL WITH SINGLE LEVER HANDLE, CHROME PLATED, 0.5 GPM.

L-3 LAVATORY 1/2" 1/2" - 2" 2"

SINK:

WHITE VITREOUS CHINA, UNDER-COUNTER MOUNT.

FAUCET:

GOOSENECK WITH DUAL WRISTBLADE HANDLES, 1.5 GPM.

LI-1

LINT

INTERCEPTOR

- - - 4" -

LINT INTERCEPTOR:

FABRICATED STEEL WITH GRAY DUCO COATING AND STAINLESS STEEL PRIMARY AND

SECONDARY LINT SCREENS, 3/16" DIAMOND PLAT COVER (SECURED AND GASKETED) AND

THREADED INLET AND OUTLET. PROVIDE A MINIMUM 50 GPM FLOW CAPACITY. MAXIMUM

FOOTPRINT 48" X 30". MAXIMUM DEPTH 20".

MS-1 MOP SINK 1/2" 1/2" - 3" 2"

SINK:

PRE-CAST TERRAZZO, FLOOR MOUNT, CORNER STYLE, 24" X 24" WITH STAINLESS STEEL EDGE

CAPS.

FAUCET:

CHROME PLATED, WALL HUNG, 8" CENTER SET, SOLID BRASS BODY, 8" SPOUT WITH VACUUM

BREAKER, 3/4" HOSE THREAD OUTLET AND PAIL HOOK.

ACCESSORIES:

36" LONG HOSE WITH 3/4" CHROME COUPLING, STAINLESS STEEL WALL BRACKET, 20GA

STAINLESS STEEL BACK SPLASH PANEL.

NFRH-1 ROOF HYDRANT 3/4" - - - - NON-FREEZE, ASSE 1057, SANITARY ROOF HYDRANT WITH NO DRAIN LINE REQUIRED.

NFWH-1 WALL HYDRANT 3/4" - - - -

CHROME PLATED, NON-FREEZE, ASSE 1019, AUTOMATIC DRAINING WITH ANTI-SIPHON

VACUUM BREAKER.

S-1 KITCHEN SINK 1/2" 1/2" - 2" 2"

SINK:

DOUBLE BOWL, COUNTERTOP, STAINLESS STEEL WITH UNDERSINK FOOD WASTE DISPOSER.

FAUCET:

CHROME PLATED, SINGLE LEVER WITH PULL-DOWN SPRAY, 1.5 GPM.

S-2

BREAKROOM

SINK

1/2" 1/2" - 2" 2"

SINK:

DOUBLE BOWL, COUNTERTOP, STAINLESS STEEL, ADA COMPLIANT.

FAUCET:

CHROME PLATED, SINGLE LEVER WITH PULL-DOWN SPRAY, 1.5 GPM.

S-3 SERVICE SINK 1/2" 1/2" - 2" 2"

SINK:

SINGLE BOWL, FLOOR MOUNTED, 18 GA 304 STAINLESS STEEL, 9" HIGH BACKSPLASH,

INTEGRAL SIDE DRAINBOARD, STAINLESS STEEL TUBULAR LEGS WITH ADJUSTABLE FEET.

FAUCET:

WALL MOUNTED, SOLID BRASS, CHROME PLATED, 8" CENTERSET, 2.2 GPM GOOSNECK SWING

SPOUT, METAL WRISTBLADE HANDLES.

S-4 WASH STATION 3/4" 3/4" - 2" 2"

BASIN:

304 STAINLESS STEEL, SEMI-CIRCULAR

FAUCETS:

4 EA. MANUAL FAUCET, INTEGRAL THERMOSTATIC MIXING VALVE.

SH-1 SHOWER 1/2" 1/2" - 2" 2"

BASE:

PRE-CAST POLYESTER RESIN WITH MOONSTONE METALLIC FINISH. STAINLESS STEEL LINEAR

DRAIN OPPOSITE DOOR. ACCESSIBLE ENTRY.

SHOWER VALVE:

PRESSURE BALANCING WITH WASHERLESS DISC CARTRIDGE, SOLID BRASS BODY, CHROME

PLATED, BUILT-IN HIGH TEMPERATURE LIMIT, INTEGRAL SERVICE STOPS, 1.5 GPM BALL JOINT

SHOWERHEAD WITH ARM AND FLANGE.

DIVERTER VALVE:

4 PORT, CHROME PLATED WITH METAL LEVER HANDLE.

SH-2 SHOWER - ADA 1/2" 1/2" - 2" 2"

BASE:

PRE-CAST POLYESTER RESIN WITH MOONSTONE METALLIC FINISH. STAINLESS STEEL LINEAR

DRAIN OPPOSITE DOOR. ACCESSIBLE ENTRY.

SHOWER VALVE:

PRESSURE BALANCING WITH WASHERLESS DISC CARTRIDGE, SOLID BRASS BODY, CHROME

PLATED, BUILT-IN HIGH TEMPERATURE LIMIT, INTEGRAL SERVICE STOPS, 1.5 GPM BALL JOINT

SHOWERHEAD WITH ARM AND FLANGE. PROVIDE ADDITIONAL 1.5 GPM HAND SPRAY WITH 24"

ADJUSTABLE VERTICAL SLIDE BAR, 60" FLEXIBLE METAL HOSE, WALL SUPPLY ELBOW AND

IN-LINE VACUUM BREAKER AND DIVERTER VALVE.

DIVERTER VALVE:

4 PORT, CHROME PLATED WITH METAL LEVER HANDLE.

U-1 URINAL 1" - - 2" 2"

BOWL:

WALL HUNG, VITREOUS CHINA, WASHDOWN ACTION.

FLUSH VALVE:

MANUAL DIAPHRAGM TYPE, 1/8 GPF.

WB-1 WALL BOX - - - 2" 1 1/2"

WALL BOX - PROVIDE WITH HAMMER ARRESTORS, QUARTER TURN ISOLATION VALVES FOR

HOT AND COLD WATER AND DRAIN RECEPTOR FOR WASHER DRAIN.

WB-2 WALL BOX - - - 2" 1 1/2"

WALL BOX - PROVIDE WITH WATER HAMMER ARRESTOR AND QUARTER TURN ISOLATION

FALVE FOR COLD WATER.

AIRCRAFT WASH SYSTEM (BID OPTION 5)

MARK SERVICE LOCATION VOLTS PHASE CYCLE HORSEPOWER

GAS

INPUT

(MBH) DESCRIPTION

AWS-1 WATER

HEATING/PUMP

PACKAGE

COMPRESS

EQUIP 192

208 3 60 10 450 HIGH PRESSURE HOT WATER SYSTEM TO PROVIDE 5 GPM AT UP TO 3000

PSI

AWS-2 REMOTE

EQUIPMENT

MODULE

AIRCRAFT

SHELTER BAY

115 1 60 0 0 DELIVERY SYSTEM WITH DUAL RETRACTABLE HOSE REELS. PROVIDE

HOSE REELS FOR SOAP/FOAM DELIVER AND HOT WATER DELIVERY.

PROVIDE 100' HOSE LENGTH. INCLUDE VARIABLE PRESSURE TRIGGER

DUAL WAND FOR HOT WATER DELIVERY.

AWS-3 CHEMICAL

MIXING STATION

COMPRESS

EQUIP 192

115 1 60 0 0 CHEMICAL SOLUTION MIX SYSTEM TO PROVIDE PRE-MIX CLEANING

COMPOUND TO SOAP/FOAM DELIVERY SYSTEM.

A

M

R E

V

IS

IO

N

S

-0

-2

AIR COMPRESSOR SCHEDULE (BID OPTION 5)

MARK

AIR FLOW

ACFM/SCFM

DISCHARGE

PRESSURE

HORSEPOWER

VOLTAGE/

PHASE

DESCRIPTION

INTEGRAL

DRYER FLA

PACKAGE

FLA

AC-1 238/179 125 psi 60 hp 460/3

PACKAGED, VARIABLE SPEED, AIR COOLED

COMPRESSOR. PROVIDE WITH INTEGRAL

AFTERCOOLER AND REFRIGERATED DRYER.

INCL 87.5

AIR RECEIVER TANK SCHEDULE (BID OPTION 5)

MARK DESCRIPTION LOCATION SERVICE

CAPACITY

(GAL) PRESSURE DIAMETER HEIGHT

RT-1 VERTICAL AIR RECEIVER

TANK

AIRCRAFT SHELTER FACILITY

CA SYSTEM 500 125 psi 3' - 0" 10' - 0"

BACKFLOW PREVENTER SCHEDULE

MARK SERVICE ASSE

MAXIMUM WORKING

PRESSURE (PSI)

MAXIMUM WORKING

TEMPERATURE (°F)

NOMINAL

DIAMETER

PRESSURE

DROP (PSI)

RATED

FLOW

(GPM)

ACTUAL

FLOW

(GPM)

BFP-1 DOMESTIC WATER 1013 175 140 3" 9 320 189

BFP-2 NON-POTABLE WATER 1013 175 140 3/4" 13 13 10

BFP-3 AIRCRAFT WASH STATION 1013 175 140 1" 10 20 10

PUMP SCHEDULE

MARK DESCRIPTION CAPACITY HEAD HP RPM VOLT PHASE

CP-1 IN-LINE CARTRIDGE CIRCULATOR, ALL BRONZE (SUITABLE FOR

POTABLE WATER)

5 GPM 3.00 psi 0.025 3250 115 1

CP-2 IN-LINE CARTRIDGE CIRCULATOR, ALL BRONZE (SUITABLE FOR

POTABLE WATER)

6 GPM 6.50 psi 0.125 3250 115 1

SP-1 ELEVATOR SUMP PUMP. PROVIDE WITH OIL DETECTION. 50 GPM 6.00 psi 0.5 3450 115 1

SP-2 SUBMERSIBLE WASTEWATER PUMP INSTALLED IN 24" DIAMETER

WET WELL THAT EXTENDS 30" BELOW INVERT OF SUBSOIL DRAIN

PIPING. PROVIDE WITH SYSTEM THAT PERMITS REMOVAL

WITHOUT DISTURBING DISCHARGE PIPING.

24 GPM 9.00 psi 0.75 3450 208 1

THERMOSTATIC MIXING VALVE SCHEDULE

MARK DESCRIPTION SERVICE LOCATION

MINIMUM

DRAW-OFF

MAXIMUM

FLOW

LEAVING

TEMP.

VOLTAGE/

PHASE

TMV-1 DIGITAL MIXING VALVE, ASSE 1070 DOMESTIC HOT

WATER

MECHANICAL

0 GPM 41 GPM 120 °F 115/1

TMV-2 DIGITAL MIXING VALVE, ASSE 1071.

ANSI Z378.1

TEPID WATER MECHANICAL

0 GPM 41 GPM 81 °F 115/1

WATER HEATER SCHEDULE

MARK DESCRIPTION

RATED

INPUT

(MBH)

RECOVERY

RATE (GPH)

TEMP.

RISE (°F)

STORAGE

CAPACITY

(GAL)

LEAVING

WATER

TEMP. (°F)

EFFICIENC

Y

VOLTAGE/

PHASE

WH-1 VERTICAL TANK GAS-FIRED

CONDENSING WATER HEATER WITH

STAINLESS STEEL STORAGE TANK.

702 770 105 130 140 96% 115/1

WH-2 VERTICAL TANK GAS-FIRED

CONDENSING WATER HEATER WITH

STAINLESS STEEL STORAGE TANK.

702 770 105 130 140 96% 115/1

TRENCH DRAIN SCHEDULE

MARK SLOPE

ACTUAL

WIDTH

LEFT

SIDE

LENGTH

RIGHT

SIDE

LENGTH

CATCH BASIN BOTTOM

OUTLET

DIAMETER DESCRIPTIONLENGTH WIDTH DEPTH

TD-1 0.5% 12" 43' - 6" 43' - 6" 1' - 6" 1' - 6" 3' - 0" 8" TRENCH:

PREFORMED, CAST-IN-PLACE SYSTEM WITH CURVED BOTTOM.

GRATE:

AIRCRAFT RATED, DUCTILE IRON WITH NON-BOLTED, PIN-LOCK

RETENTION SYSTEM.

PROVIDE DIRT COLLECTION BASKET IN CATCH BASIN.

TD-2 0.5% 12" 57' - 0" 63' - 0" 1' - 6" 1' - 6" 3' - 0" 8" TRENCH:

PREFORMED, CAST-IN-PLACE SYSTEM WITH CURVED BOTTOM.

GRATE:

AIRCRAFT RATED, DUCTILE IRON WITH NON-BOLTED, PIN-LOCK

RETENTION SYSTEM.

PROVIDE DIRT COLLECTION BASKET IN CATCH BASIN.

TD-3 1.0% 12" 18' - 6" 0' - 1" 1' - 6" 1' - 6" 2' - 0" 6" TRENCH:

PREFORMED, CAST-IN-PLACE SYSTEM WITH CURVED BOTTOM.

GRATE:

AIRCRAFT RATED, DUCTILE IRON WITH NON-BOLTED, PIN-LOCK

RETENTION SYSTEM.

PROVIDE DIRT COLLECTION BASKET IN CATCH BASIN.

TD-4 0.5% 12" 43' - 1" 43' - 1" 1' - 6" 1' - 6" 3' - 0" 8" TRENCH:

PREFORMED, CAST-IN-PLACE SYSTEM WITH CURVED BOTTOM.

GRATE:

AIRCRAFT RATED, DUCTILE IRON WITH NON-BOLTED, PIN-LOCK

RETENTION SYSTEM.

PROVIDE DIRT COLLECTION BASKET IN CATCH BASIN.

TD-7 0.5% 12" 30' - 0" 30' - 0" 1' - 6" 1' - 6" 3' - 0" 8" TRENCH:

PREFORMED, CAST-IN-PLACE SYSTEM WITH CURVED BOTTOM.

GRATE:

AIRCRAFT RATED, DUCTILE IRON WITH NON-BOLTED, PIN-LOCK

RETENTION SYSTEM.

PROVIDE DIRT COLLECTION BASKET IN CATCH BASIN.

UT-1 0.5% 16" 16' - 8" UTILITY TRENCH:

PREFORMED, CAST-IN-PLACE SYSTEM WITH CURVED BOTTOM.

ESTIMATED DEPTH OF TRENCH IS 2'.

GRATE:

DUCTILE IRON WITH NON-BOLTED, PIN-LOCK RETENTION SYSTEM.

COORDINATE FINAL SIZE WITH OWNER AND SIMULATOR

EQUIPMENT PROVIDER.

UT-2 0.5% 16" 17' - 2" UTILITY TRENCH:

PREFORMED, CAST-IN-PLACE SYSTEM WITH CURVED BOTTOM.

ESTIMATED DEPTH OF TRENCH IS 2'.

GRATE:

DUCTILE IRON WITH NON-BOLTED, PIN-LOCK RETENTION SYSTEM.

COORDINATE FINAL SIZE WITH OWNER AND SIMULATOR

EQUIPMENT PROVIDER.

NOTES:

1. RATED INPUT ADJUSTED FOR DESIGN ALTITUDE OF 6,350 FT AND HEATING VALUE OF 847 BTU/CUFT.

BOOSTER PUMP SCHEDULE

MARK DESCRIPTION

PERFORMANCE (EACH PUMP) TOTAL PACKAGE

FLOW RATE

(GPM)

PUMP

HEAD

MAX

NPSH HP RPM VOLTAGE MCA MOCP

WEIGHT

(LBS)

BP-1 TRIPLEX VARIABLE SPEED BOOSTER PUMP

PACKAGE. PROVIDE THREE (3) EA. 33% PUMPS, EACH

WITH FACTORY MATCHED VARIABLE FREQUENCY

DRIVE.

117 76 psi 4.30 psi 10 3600 460/3/60 46.5 A 50 A 2937

NOTES:

1. COMPRESSOR AIRFLOW HAS BEEN ADJUSTED FOR OPERATION AT AN ALTITUDE OF 6300 FEET.

2. ALL MOTORS SHALL BE SELECTED FOR OPERATION AT AN ALTITUDE OF 6300 FEET.

BRODIE B. B. HEFLIN

OF TEXASS

TATE

ALNOI

SS

E

F O

R P

ENG

IN

E E

R

NSEDECI

L 106046

US Army Corps of Engineers Omaha District ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

A F

-1

-0

-W F

R

M

A R

C H

C H

O F

F F

IL

E

N A

M E

O M

A H

A D

IS

T

R

A H

A

N E

B R

A S

K A

F Y

H

E L

O /T

R F

/M A

IN

T

E N

A N

C E

F A

C

IL

IT

Y

P R

O J E

C T

N U

M B

E R

G

H L

N A

F E

W A

R R

E N

A F

B

W Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t

F o rt

W o rt h

T X

READY-TO-ADVERTISE (RTA) DESIGN

TEXAS REGISTERED

ENGINEERING FIRM F-2966

P-602

P L U

M B

IN

G

S C

H E

D U

L E

S

D K

E M

P

C R

O D

P B

A K

E R

F E

-G

H L

N

A P

-6

PRESSURE REDUCING VALVE SCHEDULE

MARK SERVICE DESCRIPTION

MAXIMUM

WORKING

PRESSURE

(PSIG)

MINIMUM

WORKING

PRESSURE

(PSIG)

MAXIMUM

WORKING

TEMPERATURE

(°F)

NOMINAL

DIAMETER

SET

PRESSURE

PRESSURE

FALL-OFF

DESIGN

FLOW

(SCFH) NOTES

PRV-1 BUILDING

NATURAL GAS

SELF-CONTAINED 150 50 70 2" 5 PSIG 1%

ABSOLUTE

14,800 1,3

PRV-2 BUILDING

NATURAL GAS

SELF-CONTAINED 150 5 70 2" 2 PSIG 1%

ABSOLUTE

14,800 1

PRV-3 BUILDING

NATURAL GAS

SELF-CONTAINED 150 50 70 2" 5 PSIG 1%

ABSOLUTE

14,800 1

PRV-4 WH-1 SELF-CONTAINED 5 1 70 1 1/4" 7 IN WC < 1.0 IN WC 829 1,2

PRV-5 WH-2 SELF-CONTAINED 5 1 70 1 1/4" 7 IN WC < 1.0 IN WC 829 1,2

PRV-6 DOAU-1

(HEATER)

SELF-CONTAINED 5 1 70 1 1/4" 7 IN WC < 1.0 IN WC 570 1,4

PRV-7 DOAU-1

(HUMIDIFIER)

SELF-CONTAINED 5 1 70 1 1/2" 7 IN WC < 1.0 IN WC 1060 1,4

PRV-8 MAU-1 SELF-CONTAINED 5 1 70 1 1/4" 7 IN WC < 1.0 IN WC 416 1,4

PRV-9 AWS-1 SELF-CONTAINED 5 1 70 1 1/4" 7 IN WC < 1.0 IN WC 472 1,4

PRV-10 ERU-1 SELF-CONTAINED 5 1 70 3/4" 7 IN WC < 1.0 IN WC 364 1,4

PRV-11 ERU-2 SELF-CONTAINED 5 1 70 3/4" 7 IN WC < 1.0 IN WC 260 1,4

PRV-12 ERU-3 SELF-CONTAINED 5 1 70 3/4" 7 IN WC < 1.0 IN WC 364 1,4

PRV-13 ERU-4 (BASE

BID)

SELF-CONTAINED 5 1 70 3/4" 7 IN WC < 1.0 IN WC 364 1,4

PRV-14 ERU-4 (BID OPT

2)

SELF-CONTAINED 5 1 70 3/4" 7 IN WC < 1.0 IN WC 280 1,4

PRV-15 ERU-5 (BID OPT

2)

SELF-CONTAINED 5 1 70 3/4" 7 IN WC < 1.0 IN WC 260 1,4

PRV-16 B-1 SELF-CONTAINED 5 1 70 2" 7 IN WC < 1.0 IN WC 2,835 1,2

PRV-17 B-2 SELF-CONTAINED 5 1 70 2" 7 IN WC < 1.0 IN WC 2,835 1,2

PRV-18 B-3 (BID OPT 4) SELF-CONTAINED 5 1 70 2" 7 IN WC < 1.0 IN WC 2,835 1,2

NOTES:

1. SITE ELEVATION IS 6,300 FEET, 0 PSIG IS EQUAL TO 11.64 PSIA.

2. REGULATORS SHALL BE VENTED TO ATMOSPHERE.

3. MONITOR REGULATOR WITH EXTERNAL CONTROL TAP FOR REMOTE DOWNSTREAM CONTROL.

4. REGULATOR WITH OUTDOOR VENT PROTECTORS.

PRESSURE TANK SCHEDULE

MARK LOCATION SERVES

TANK VOLUME

(GAL) TYPE

REQUIRED

ACCEPTANCE (GAL)

SHIPPING

WEIGHT (LBS)

OPERATING

WEIGHT (LBS)

(OD X H -

INCHES) NOTES

ET-1 MECHANICAL 284 HYDRODYNAMIC

TANK

132 DIAPHRAGM 153 508 1800 30 X 74 ASME

ET-2 MECHANICAL 284 EXPANSION

TANK

153 DIAPHRAGM 132 391 1500 24 X 87 ASME

NOTES:

1. PROVIDE WITH LOW SUCTION PRIME LINE AND LOSS OF PRIME SENSOR.

A

M

R E

V

IS

IO

N

S

-0

-2

TATE

ALNOI

SS

E

F O

R P

ENG

IN

E E

R

NSEDECI

L 106046

US Army Corps of Engineers Omaha District ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

A F

-1

-0

-W F

R

M

A R

C H

C H

O F

F F

IL

E

N A

M E

O M

A H

A D

IS

T

R

A H

A

N E

B R

A S

K A

F Y

H

E L

O /T

R F

/M A

IN

T

E N

A N

C E

F A

C

IL

IT

Y

P R

O J E

C T

N U

M B

E R

G

H L

N A

F E

W A

R R

E N

A F

B

W Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t

F o rt

W o rt h

T X

READY-TO-ADVERTISE (RTA) DESIGN

TEXAS REGISTERED

ENGINEERING FIRM F-2966

P-615

B

ID

O P

T

IO

N

C

R A

S H

/F

IR

E R

E S

C U

E F

A C

IL

IT

Y

P L U

M B

IN

G

S C

H E

D U

L E

S

Y M

A S

H N

I

Y M

A S

H N

I

P B

A K

E R

F E

-G

H L

N

A P

-6

AIR COMPRESSOR SCHEDULE (BID OPTION 6)

MARK

AIRFLOW

(ACFM/SCFM)

DISCHARGE

PRESSURE

MAX

HORSEPOWER

VOLTAGE/

PHASE/HZ

INTEGRAL

DRYER FLA

PACKAGE

FLA DESCRIPTION

AC-2 22/17 175 psi 7.5 208/3/60 INCL 33.8

TWO STAGE AIR COOLED COMPRESSOR. PROVIDE

WITH AFTER COOLER AND REFRIGERATED DRYER.

FACTORY MOUNTED ON VERTICAL 80 GALLON

RECEIVER.

BACKFLOW PREVENTER SCHEDULE

MARK SERVICE ASSE STD

MAXIMUM WORKING

PRESSURE (PSI)

MAXIMUM WORKING

TEMPERATURE (°F)

NOMINAL

DIAMETER

PRESSURE

DROP (PSI)

RATED

FLOW (GPM)

ACTUAL

FLOW (GPM)

BFP-4 DOMESTIC WATER 1013 175 110 2 1/2" 12 113 84

BFP-5 NON-POTABLE WATER 1013 175 110 3" 12 175 150

CIRCULATING PUMP SCHEDULE

MARK DESCRIPTION CAPACITY HEAD HP RPM VOLTAGE PHASE HERTZ

CP-3 DOMESTIC HOT WATER 3 GPM 7.0 0.04 3250 115 V 1 60

PLUMBING FIXTURE SCHEDULE

MARK FIXTURE DCW DHW WASTE VENT DESCRIPTION

EEWS-1

EMERGENCY SHOWER

AND EYEWASH

1 1/2" 1 1/4" - -

COMBINATION EMERGENCY SHOWER AND EYE/FACE WASH, FLOOR MOUNTED. PROVIDE

WITH ALARM STATION INCLUDING HORN AND STROBE.

EWC-1 WATER COOLER 1/2" - 2" 2"

ELECTRIC, REFRIGERATED, WALL HUNG, BI-LEVEL WITH BOTTLE FILLER AND INTEGRAL

FRONT ACCESS WATER FILTER. 8.0 GPH AT 90°F AMBIENT.

FD-1 3" FLOOR DRAIN - - 3" 2" 3" FLOOR DRAIN WITH HEAVY DUTY STRAINER. PROVIDE WITH ASSE 1072 TRAP GUARD.

FS-1 4" FLOOR SINK - - 4" 2" 4" FLOOR SINK WITH HEAVY DUTY STRAINER. PROVIDE WITH ASSE 1072 TRAP GUARD.

GH-1

NATURAL GAS QUICK

DISCONNECT

3/4" NATURAL GAS QUICK DISCONNECT FOR PATIO GRILL.

36 MBH USED FOR DESIGN.

HB-1 HOSE BIBB 1/2" - - -

WALL CASING, PLATE AND FLANGE, FURNISHED WITH POLYCARBONATE WHEEL HANDLE

AND LOOSE TEE KEY, VACUUM BREAKER.

HB-2 HOT/COLD HOSE BIBB 3/4" 3/4" - -

HOT/COLD MIXER, AUTOMATIC DRAIN, FURNISHED WITH POLYCARBONATE WHEEL HANDLE

AND LOOSE TEE KEY, HOSE CONNECTION, VACUUM BREAKER.

HB-3 2 1/2" FIRE HOSE BIBB 3" (NPW) - - -

HOSE CONNECTION FOR FIRE TRUCK FILL. PROVIDE WITH BRASS GATE VALVE AND A 2-1/2

INCH 90 WITH STANDARD FIRE HOSE CONNECTION THREAD.

L-2 LAVATORY 1/2" 1/2" 1-1/2" 1-1/2"

SINK:

WHITE VITREOUS CHINA, WALL MOUNT.

FAUCET:

MANUAL WITH SINGLE LEVER HANDLE, CHROME PLATED, 0.5 GPM WITH POP-UP STRAINER.

LI-2 LINT INTERCEPTOR - - 4"

LINT INTERCEPTOR:

FABRICATED STEEL WITH GRAY DUCO COATING AND STAINLESS STEEL PRIMARY AND

SECONDARY LINT SCREENS, 3/16" DIAMOND PLAT COVER (SECURED AND GASKETED) AND

THREADED INLET AND OUTLET. PROVIDE A MINIMUM 50 GPM FLOW CAPACITY. MAXIMUM

FOOTPRINT 48" X 30". MAXIMUM DEPTH 20".

MS-1 MOP SINK 3/4" 3/4" 3" 1-1/2"

SINK:

PRE-CAST TERRAZZO, FLOOR MOUNT, CORNER STYLE, 24" X 24" WITH STAINLESS STEEL

EDGE CAPS.

FAUCET:

CHROME PLATED, WALL HUNG, 8" CENTER SET, SOLID BRASS BODY, 8" SPOUT WITH VACUUM

BREAKER, 3/4" HOSE THREAD OUTLET AND PAIL HOOK.

ACCESSORIES:

36" LONG HOSE WITH 3/4" CHROME COUPLING, STAINLESS STEEL WALL BRACKET, 20GA

STAINLESS STEEL BACK SPLASH PANEL.

NFRH-1

NONFREEZE ROOF

HYDRANT

3/4" - -- -

3/4" FREEZELESS SANITARY ROOF HYDRANT; ASSE 1057; HOSE CONNECTION WITH

BACKFLOW PREVENTER; NO DRAIN REQUIRED

NFWH-1

NONFREEZE WALL

HYDRANT

3/4" - - -

CHROME PLATED, NON-FREEZE, ASSE 1019, AUTOMATIC DRAINING WITH ANTI-SIPHON

VACUUM BREAKER.

S-1 SINK 1/2" 1/2" 2" 1-1/2"

SINK:

DOUBLE BOWL, COUNTERTOP, STAINLESS STEEL, ADA COMPLIANT WITH UNDERSINK FOOD

WASTE DISPOSER.

FAUCET:

CHROME PLATED, SINGLE LEVER, STRAINER WITH PULL-DOWN SPRAY, 1.5 GPM.

S-5 SERVICE SINK 1/2" 1/2" 2" 2"

SINK:

SINGLE BOWL, FLOOR MOUNTED, 18 GA 304 STAINLESS STEEL

FAUCET:

CHROME FINISH, 2 HOLE, 8" CENTERSET, BRASS, 2.2 GPM OULET, BRASS GOOSENECK

SWING SPOUT, 9" FROM WALL TO OUTLET, METAL WRIST BLADE HANDLES, 1/2" NPT FEMALE

INLETS.

SH-1 SHOWER DRAIN 1/2" 1/2" 2" 1-1/2"

BASE:

PRE-CAST POLYESTER RESIN WITH MOONSTONE METALLIC FINISH. STAINLESS STEEL

LINEAR DRAIN OPPOSITE DOOR. ACCESSIBLE ENTRY.

SHOWER VALVE:

ASSE 1016 PRESSURE BALANCING WITH WASHERLESS DISC CATRIDGE, SOLID BRASS BODY,

CHROME PLATED, BUILT-IN HIGH TEMPERATURE LIMIT, INTEGRAL SERVICE STOPS, 1.5 GPM

BALL JOINT SHOWERHEAD WITH ARM AND FLANGE.

DIVERTER VALVE:

4 PORT, CHROME PLATED WITH METAL LEVER HANDLE.

WC-2 WATER CLOSET 1 1/4" - 4" 2"

BOWL:

ADA HEIGHT, WALL HUNG, VITREOUS CHINA, SIPHON JET.

FLUSH VALVE:

MANUAL DIAPHRAGM TYPE, 1.28 GPF.

THERMOSTATIC MIXING VALVE SCHEDULE

MARK DESCRIPTION

MINIMUM

DRAW-OFF

MAXIMUM

FLOW

LEAVING

TEMP.

PRESSURE

DROP (PSI)

VOLTAGE/

PHASE NOTES

TMV-3 CFR MECHANICAL ROOM - WATER HEATER MIXING VALVE 2 GPM 24 GPM 120 °F 15 115/1 1

TMV-4 CFR APPARATUS BAY - EMERGENCY EYEWASH/SHOWER MIXING VALVE 0 GPM 23 GPM 85 °F 12 115/1 2

WATER HEATER SCHEDULE

MARK DESCRIPTION RATED INPUT

RECOVERY

RATE (GPH) TEMP. RISE (°F)

STORAGE

CAPACITY (GAL)

LEAVING WATER

TEMPERATURE EFFICIENCY

VOLTAGE/

PHASE

WH-3 CRF MECHANICAL ROOM 300 MBH 343 105 100 140 96 120/1

WH-4 CRF MECHANICAL ROOM 300 MBH 343 105 100 140 96 120/1

NOTES:

1. REFER TO ARCHITECTURAL DRAWINGS FOR FIXTURE MOUNTING HEIGHTS.

NOTES:

1. PROVIDE PUMP WITH BMS CONTROL.

NOTES:

1. ASSE 1017

2. PROVIDE EMERGENCY SHOWER AND EYEWASH MIXING VALVE WITH 15 GPM CONSTANT COLD WATER FLOW IN HOT WATER

FAILURE MODE TO OPEN OUTLET AT 45 PSI PRESSURE DROP (ASSE 1071).

NOTES:

1. RATED INPUT ADJUSTED FOR DESIGN ALTITUDE OF 6300 FEET AND HEATING VALUE OF 847 BTU/CUFT.

2. PROVIDE WALL MOUNTED THERMOSTATIC MIXING VALVE ADJACENT TO WATER HEATERS.

3. PROVIDE CPVC CONCENTRIC VENT TERMINATION.

4. PROVIDE SYSTEM IN COMPLIANCE WITH ASHRAE 90.1-2010 FOR EFFICIENCY AND STANDBY LOSS.

5. PROVIDE CONDENSATE NEUTRALIZATION KIT FOR FLUE GAS DRAIN.

6. NATURAL GAS WILL BE DELIVERED BETWEEN 8 AND 10 INCHES W.C. OR AS ADJUSTED ON PRV.

TRENCH DRAIN SCHEDULE

MARK SLOPE

ACTUAL

WIDTH

INLINE CATCH BASIN TRENCH

LENGTH

OUTLET

DIAMETER DESCRIPTIONLENGTH WIDTH DEPTH

TD-5 1.0% 12" 1' - 2" 1' - 0" 2' - 0" 25' - 8" 4" TRENCH:

PREFORMED, CAST-IN-PLACE SYSTEM WITH CURVED BOTTOM. BOTTOM

OUTLET CATCH BASIN WITH STAINLESS STEEL SEDIMENT BASKET.

GRATE:

HEAVY DUTY RATED, DUCTILE IRON WITH NON-BOLTED, PIN-LOCK

RETENTION SYSTEM.

TD-6 1.0% 12" 1' - 2" 1' - 0" 2' - 0" 36' - 2 1/8" 4" TRENCH:

PREFORMED, CAST-IN-PLACE SYSTEM WITH CURVED BOTTOM. BOTTOM

OUTLET CATCH BASIN WITH STAINLESS STEEL SEDIMENT BASKET.

GRATE:

HEAVY DUTY RATED, DUCTILE IRON WITH NON-BOLTED, PIN-LOCK

RETENTION SYSTEM.

NOTES:

1. AIRFLOW HAS BEEN ADJUSTED FOR OPERATION AT AN ALTITUDE OF 6300 FEET.

2. DERATE MOTORS FOR OPERATION AT AN ALTITUDE OF 6300 FEET.

PRESSURE REDUCING VALVE SCHEDULE

MARK SERVICE DESCRIPTION

MAXIMUM

WORKING

PRESSURE

(PSIG)

MINIMUM

WORKING

PRESSURE

(PSIG)

MAXIMUM

WORKING

TEMPERATURE

(°F)

NOMINAL

DIAMETER

SET

PRESSURE

PRESSURE

FALL-OFF

DESIGN

FLOW NOTES

PRV-21 BUILDING

NATURAL

GAS

SELF-CONTAINED 150 50 70 2" 5.0 PSIG 1%

ABSOLUTE

1,250

SCFH

NOTES 1, 3

PRV-22 BUILDING

NATURAL

GAS

SELF-CONTAINED 150 5 70 2" 2.0 PSIG 1%

ABSOLUTE

1,250

SCFH

NOTES 1

PRV-24 WH-3 SELF-CONTAINED 5 1 70 3/4" 7 IN WC <1.0 IN WC 300 SCFH NOTES 1, 2

PRV-25 WH-4 SELF-CONTAINED 5 1 70 3/4" 7 IN WC <1.0 IN WC 300 SCFH NOTES 1, 2

PRV-26 DOAU-2

(HEATER)

SELF-CONTAINED 5 1 70 1/2" 7 IN WC <1.0 IN WC 88 SCFH NOTES 1, 4

PRV-27 DOAU-2

(HUMIDIFIER)

SELF-CONTAINED 5 1 70 1/2" 7 IN WC <1.0 IN WC 85 SCFH NOTES 1, 4

PRV-28 MAU-2 SELF-CONTAINED 5 1 70 3/4" 7 IN WC <1.0 IN WC 220 SCFH NOTES 1, 4

PRV-29 B-4 SELF-CONTAINED 5 1 70 3/4" 7 IN WC <1.0 IN WC 200 SCFH NOTES 1, 2

PRV-30 GH-1 SELF-CONTAINED 5 1 70 1/2" 7 IN WC <1.0 IN WC 36 SCFH NOTES 1, 4

NOTES:

1. SITE ELEVATION IS 6,300 FEET, 0 PSIG IS EQUAL TO 11.64 PSIA.

2. REGULATOR SHALL BE VENTED TO ATMOSPHERE.

3. MONITOR REGULATOR WITH EXTERNAL CONTROL TAP FOR REMOTE DOWNSTREAM CONTROL.

4. REGULATOR WITH OUTDOOR VENT PROTECTORS.

PRESSURE TANK SCHEDULE

MARK LOCATION SERVES

TANK VOLUME

(GAL) TYPE

REQUIRED

ACCEPTANCE (GAL)

SHIPPING

WEIGHT (LBS)

OPERATING

WEIGHT (LBS)

(OD X H -

INCHES) NOTES

ET-3 MECH 124 DOMESTIC HOT

WATER

37 VERTICAL

DIAPHRAGM

5.6 225 295 24 X 37 1, 2

NOTES:

1. ASME STAMPED

2. PRECHARGED TO 65 PSIG

A

M

R E

V

IS

IO

N

S

-0

-2

TATE

ALNOI

SS

E

F O

R P

ENG

IN

E E

R

NSEDECI

L 106046

US Army Corps of Engineers Omaha District ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

A F

-1

-0

-W F

R

M

A R

C H

C H

O F

F F

IL

E

N A

M E

O M

A H

A D

IS

T

R

A H

A

N E

B R

A S

K A

F Y

H

E L

O /T

R F

/M A

IN

T

E N

A N

C E

F A

C

IL

IT

Y

P R

O J E

C T

N U

M B

E R

G

H L

N A

F E

W A

R R

E N

A F

B

W Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t

F o rt

W o rt h

T X

READY-TO-ADVERTISE (RTA) DESIGN

TEXAS REGISTERED

ENGINEERING FIRM F-2966

M-604

S C

H E

D U

L E

S

B B

S /R

C

B B

S /R

C

B H

F E

-G

H L N

A M

-6

AIR TERMINAL DEVICE SCHEDULE

MARK SERVICE DESCRIPTION MATERIAL

NECK

SIZE FACE SIZE

MAXIMUM

THROW @

100 FPM (FT)

MAXIMUM

NOISE

CRITERIA

MAXIMUM

FLOW

MAX

PRESSURE

DROP (IN. W.G.)

AD-2 SUPPLY AIR LAY-IN ALUMINUM 6"Ø 24"X24" 4 25 200 0.099

AD-3 SUPPLY AIR LAY-IN ALUMINUM 8"Ø 24"X24" 25

AD-4 SUPPLY AIR LAY-IN ALUMINUM 10"Ø 24"X24" 7 25 440 0.066

AD-6 SUPPLY AIR LINEAR SLOT ALUMINUM 6"Ø 4'X6" 9 25 160 0.121

AD-7 SUPPLY AIR LINEAR SLOT ALUMINUM 8"Ø 4'X6" 16 25 210 0.096

AD-8 SUPPLY/RETURN AIR LINEAR SLOT ALUMINUM 8"Ø 4'X5.25" 3 25 160 0.065

AD-9 OUTSIDE AIR SURFACE MOUNT ALUMINUM 6"Ø 12"X12" 6 25 200 0.114

AD-11 OUTSIDE AIR LAY-IN ALUMINUM 6"Ø 24"X24" 4 25 200 0.099

AD-12 OUTSIDE AIR LAY-IN ALUMINUM 8"Ø 24"X24" 7 25 350 0.101

AD-13 OUTSIDE AIR LAY-IN ALUMINUM 14"Ø 24"X24" 8 25 650 0.040

AD-14 OUTSIDE AIR LINEAR SLOT ALUMINUM 6"Ø 4'X6" 9 25 160 0.121

AD-15 OUTSIDE AIR LINEAR SLOT ALUMINUM 12"Ø 4'X6" 21 25 290 0.065

AD-16 RETURN SURFACE MOUNT ALUMINUM 10"X10" 12"X12" - 25 475 0.040

AD-17 RETURN LAY-IN ALUMINUM 22"X22" 24"X24" - 25 0.040

AD-18 RETURN LINEAR SLOT ALUMINUM 10"Ø 4'X6" - 25 250 0.085

AD-19 RETURN LINEAR SLOT ALUMINUM 12"Ø 4'X6" - 25 290 0.065

AD-20 EXHAUST SURFACE MOUNT ALUMINUM 6"X6" 12"X12" - 25 150 0.040

AD-21 EXHAUST SURFACE MOUNT ALUMINUM 8"X8" 12"X12" - 25 300 0.040

AD-22 EXHAUST SURFACE MOUNT ALUMINUM 10"X10" 12"X12" - 25 475 0.040

AD-23 EXHAUST LAY-IN ALUMINUM 6"X6" 24"X24" - 25 115 0.040

AD-24 EXHAUST LAY-IN ALUMINUM 8"X8" 24"X24" - 25 300 0.040

AD-25 EXHAUST LAY-IN ALUMINUM 10"X10" 24"X24" - 25 475 0.040

AD-26 SIDEWALL STEEL 6"X6" -

AD-27 OUTSIDE AIR SIDEWALL STEEL 6"X6" - 18 25 115 0.022

AD-28 SUPPLY AIR SIDEWALL STEEL 8"X6" - 21 25 260 0.106

AD-29 OUTSIDE AIR SIDEWALL STEEL 8"X6" - 21 25 260 0.106

AD-30 SUPPLY AIR SIDEWALL STEEL 12"X10" - 31 25 575 0.106

AD-31 OUTSIDE AIR SIDEWALL STEEL 12"X10" - 31 25 575 0.106

AD-32 OUTSIDE AIR SIDEWALL STEEL 12"X12" - 34 25 705 0.106

AD-33 SUPPLY AIR LINEAR SLOT ALUMINUM 6"Ø 3'-7 1/2" X6" 9 25 145 0.121

AD-34 SUPPLY AIR LINEAR SLOT ALUMINUM 10"Ø 4'X6" 19 25 250 0.085

AD-35 EXHAUST SIDEWALL ALUMINUM 6"X6" - - 25 115 0.022

AD-36 EXHAUST LAY-IN ALUMINUM 22"X22" 24"X24" 4 25 2500 0.099

AD-37 RETURN SIDEWALL STEEL 10"X10" 12"X12" - 25 475 0.040

AD-38 RETURN SIDEWALL STEEL 8"X8" 10"X10" - 25 300 0.040

AD-39 EXHAUST SIDEWALL STEEL 8"X8" 10"X10" - 25 300 0.040

AD-40 SUPPLY AIR SIDEWALL ALUMINUM 12"X10" - 31 25 575 0.106

AD-41 OUTSIDE AIR LAY-IN ALUMINUM 10"Ø 24"X24" 7 25 440 0.066

DL-1 SUPPLY AIR DRUM LOUVER ALUMINUM 24"X6" 24" X 6" 35 44 1040 0.510

DL-2 SUPPLY AIR DRUM LOUVER ALUMINUM 18"X6" 18" X 6" 28 35 810 0.510

HVLS FAN SCHEDULE

MARK SERVICE BID OPTION

MIN. FAN

DIA. (FT)

MIN.

AIRFLOW

(CFM)

ELECTRICAL

WEIGHT

MOTOR

HP VOLTAGE PHASE FLA

HVLS-1 ALERT HANGAR BASE BID 6 9600 1 460 3 1.69 150

HVLS-2 ALERT HANGAR BASE BID 6 9600 1 460 3 1.69 150

HVLS-3 MAINTENANCE HANGAR BASE BID 6 9600 1 460 3 1.69 150

HVLS-4 MAINTENANCE HANGAR BASE BID 6 9600 1 460 3 1.69 150

HVLS-5 MAINTENANCE HANGAR BASE BID 6 12720 1 460 3 1.69 150

HVLS-6 SHELTER HANGAR BASE BID 6 12720 1 460 3 1.69 150

HVLS-7 SHELTER HANGAR BASE BID 6 9600 1 460 3 1.69 150

HVLS-8 SHELTER HANGAR BASE BID 6 12720 1 460 3 1.69 150

HVLS-9 SHELTER HANGAR BID OPTION 2 6 9600 1 460 3 1.69 150

HVLS FAN SCHEDULE NOTES:

1. PROVIDE WITH MANUFACTURER PROVIDE VFD AND WALL-MOUNTED CONTROL PANEL.

2. PROVIDE CLEARANCE AS REQUIRED BY THE MANUFACTURER.

3. FANS TO PROVIDE 50 FPM AIR MOVEMENT AT 48" ABOVE THE FINISHED FLOOR.

4. MOUNT WITH BOTTOM OF FAN AT 38'-0" ABOVE BUILDING LEVEL 1 FINISHED FLOOR.

5. HVLS-1, 2, 3, 4, 7, AND 9 IS AT 64 RPM WHEN OPERATED AT THE SCHEDULED AIR FLOW.

6. HVLS-5, 6, AND 8 IS AT 85 RPM WHEN OPERATED AT THE SCHEDULED AIR FLOW.

MAKE UP AIR UNIT SCHEDULE

MARK LOCATION SERVICE

OUTDOOR

AIRFLOW

(CFM)

SUPPLY

E.S.P. (IN.

W.C.)

SUPPLY

T.S.P. (IN.

W.C.)

HIGH EFFICIENCY CONDENSING GAS HEATER SUPPLY FAN ELECTRICAL MAX UNIT SIZE (IN)

MAX UNIT

WEIGHT

(LBS)TYPE

FACE

VELOCITY

(FPM)

EAT

(°F)

LAT

(°F)

GAS

INPUT

(MBH)

TOTAL

CAPACITY

(MBH) FAN TYPE

DRIVE

TYPE MAX BHP

MOTOR

HP

VOLT/

PHASE FLA LENGTH WIDTH HEIGHT

MAU-1 VEHICLE BAY ROOF 197 - G-4 BEARCAT 5135 0.75 2.80 CONDENSING GAS 90% EFFICIENT 500 1 67 352 317 FORWARD CURVED BELT 4.7 7.5 480/3 10.6 92 72 44 2300

MAU-2 CFR ROOF CFR BUILDING 1800 0.75 2.65 CONDENSING GAS 90% EFFICIENT 500 1 67 125 111 FORWARD CURVED BELT 1.5 5 208/3 17.2 92 72 44 2300

MAKEUP AIR UNIT SCHEDULE NOTES:

1. PROVIDE VFD RATED MOTORS, VFD BY

MANUFACTURER.

2. SINGLE-POINT WIRING, ELECTRICAL TO PROVIDE

MAIN DISCONNECT.

3. MAU-2 IS FOR BID OPTION 1.

4. PROVIDE 24" MANUFACTURER SUPPLIED ROOF

CURB.

5. PROVIDE MERV-8 PRE FILTER AND LOW PRESSUE

DROP MERV-13 BAG FILTER WITH INITIAL PRESSURE

DROP OF 0.35" AND MAXIMUM DIRTY FILTER DROP

OF 0.55". FILTER TO HAVE 1 YEAR LIFE.

6. PROVIDE WITH CONDENSATE NEUTRALIZATION KIT

FOR CONDENSING FURNACE.

7. PROVIDE REGULATOR RATED FOR FURNACE INPUT

FOR GAS CONNECTION.

FAN SCHEDULE

MARK LOCATION SERVICE UNIT TYPE

TOTAL AIR

(CFM)

E.S.P. (IN.

W.C.)

ELECTRICAL

WEIGHT

(LBS)

DRIVE

TYPE FAN HP FLA PHASE VOLTAGE

EF-1 ROOF 197 - G-4 BEARCAT EXHAUST CENTRIFUGAL DOWNBLAST 2335 0.75 BELT 0.75 3.7 1 208 95

EF-2 158 - MECHANICAL 158 - MECHANICAL ROOM EXHAUST CENTRIFUGAL INLINE 3595 0.75 BELT 1.5 11 1 208 182

EF-3 ROOF 166 - ELECTRICAL ROOM EXHAUST CENTRIFUGAL DOWNBLAST 2615 0.75 DIRECT 1 8.8 1 208 71

EF-4 191 - FIRE SUPPRESSION EQUIP 191 - FIRE SUPPRESSION EQUIP EXHAUST CENTRIFUGAL INLINE 1485 0.50 DIRECT 0.75 10.6 1 120 60

EF-5 135 - FIRE SUPPRESSION 135 - FIRE SUPPRESSION EXHAUST CENTRIFUGAL INLINE 840 0.50 DIRECT 0.25 3.7 1 120 47

EF-6 192 - COMPRESS EQUIP 192 - COMPRESS EQUIP EXHAUST CENTRIFUGAL INLINE 830 0.50 DIRECT 0.25 3.7 1 120 47

EF-7 284 - MECHANICAL 284 - MECHANICAL ROOM EXHAUST CENTRIFUGAL INLINE 2770 0.75 DIRECT 1 12 1 120 149

EF-8 LIGHTING VAULT CAP 196 - LIGHTING VAULT EXHAUST CENTRIFUGAL UPBLAST 1325 0.50 BELT 0.33 7.2 1 120 59

EF-9 CFR BUILDING - ROOF 107 - CRASH RESPONSE EXHAUST CENTRIFUGAL DOWNBLAST 1630 0.75 BELT 0.5 9.8 1 120 90

EF-10 CFR BUILDING - ROOF 124 - MECHANICAL ROOM EXHAUST CENTRIFUGAL DOWNBLAST 1105 0.50 DIRECT 0.5 6.2 1 120 47

EF-11 CFR BUILDING - ROOF 122 - ELECTRICAL ROOM EXHAUST CENTRIFUGAL DOWNBLAST 1590 0.50 DIRECT 0.5 6.7 1 120 56

EF-12 CFR BUILDING - ROOF 105 - HOSE STORAGE, 106 - EQUIPMENT MAINT, 108 - PPE CENTRIFUGAL DOWNBLAST 165 0.50 DIRECT 0.25 5.8 1 120 90

EF-13 ROOF 163 - SIM COMM CENTRIFUGAL DOWNBLAST 160 0.25 DIRECT 0.03 1 1 115 25

FAN SCHEDULE NOTES:

1. FOR EF-2: PROVIDE VFD RATED MOTORS, VFD BY MANUFACTURER.

2. PROVIDE INTEGRAL DISCONNECT AND STARTER.

3. EF-9, EF-10, EF-11 AND EF-12 ARE FOR BID OPTION 1.

4. PROVIDE 24" MANUFACTURER SUPPLIED ROOF CURB FOR ROOF

MOUNTED EQUIPMENT.

5. FOR EF-1, 3, 4, 5, 6, 7, 8, 9, 10, 11, AND 12: PROVIDE WITH ECM MOTOR.

AIR TERMINAL DEVICE SCHEDULE NOTES:

1. COORDINATE FINISHES WITH ARCHITECTURE.

2. COORDINATE MOUNT TYPE WITH ARCHITECTURAL CEILING.

GENERAL NOTES - SCHEDULES

ALL EQUIPMENT SELECTED AT 6350 FT. ELEVATION ABOVE SEA LEVEL

KITCHEN HOOD SCHEDULE

MARK LOCATION UNIT TYPE

HOOD

CONSTRUCTION

FAN ELECTRICAL UNIT

WIDTHAIRFLOW (CFM) TYPE VOLTAGE PHASE WATTS

KH-1 KITCHEN 299 WALL MOUNTED RECIRCULATION HOOD SYSTEM STAINLESS STEEL 600 CENTRIFUGAL 120 1 530 3' - 0"

KH-2 KITCHEN 299 WALL MOUNTED RECIRCULATION HOOD SYSTEM STAINLESS STEEL 600 CENTRIFUGAL 120 1 530 3' - 0"

KH-3 CFR - KITCHEN 111 WALL MOUNTED RECIRCULATION HOOD SYSTEM STAINLESS STEEL 600 CENTRIFUGAL 120 1 530 3' - 0"

KITCHEN HOOD SCHEDULE NOTES:

1. REFER TO INTERIORS PLANS AND SPECIFICATIONS.

2. PROVIDE SYSTEM WITH CENTRIFUGAL INTEGRATED BLOWER AND RECIRCULATION MODE KIT.

3. PROVIDE SYSTEM WITH SPEED CONTROLS DISPLAY, TIMER AND CONTROLS TO AUTOMATICALLY TURN ON BLOWER UPON

EXCESSIVE HEAT SENSED.

4. PROVDE SYSTEM WITH CHARCOAL REPLACEABLE FILTERS.

5. PROVIDE HOOD WITH INTEGRAL LIGHTING.

6. KH-3 FOR BID OPTION 1.

350 0.1017

SUPPLY AIR 19018 25 0.106

A

M

R E

V

IS

IO

N

S

-0

-2

TATE

ALNOI

SS

E

F O

R P

ENG

IN

E E

R

NSEDECI

L 106046

US Army Corps of Engineers Omaha District ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

A F

-1

-0

-W F

R

M

A R

C H

C H

O F

F F

IL

E

N A

M E

O M

A H

A D

IS

T

R

A H

A

N E

B R

A S

K A

F Y

H

E L

O /T

R F

/M A

IN

T

E N

A N

C E

F A

C

IL

IT

Y

P R

O J E

C T

N U

M B

E R

G

H L

N A

F E

W A

R R

E N

A F

B

W Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t

F o rt

W o rt h

T X

READY-TO-ADVERTISE (RTA) DESIGN

TEXAS REGISTERED

ENGINEERING FIRM F-2966

M-605

S C

H E

D U

L E

S

B B

S /R

C

B B

S /R

C

B H

F E

-G

H L N

A M

-6

VARIABLE AIR VOLUME BOX SCHEDULE

MARK

UNIT

SIZE AHU SERVED

MAX

AIRFLOW

(CFM)

MIN

AIRFLOW

(CFM)

MAX AIR

PRESSURE

DROP (IN.

W.C.)

VAV2-13 6 AHU-2 55 0 0.25

VAV2-14 6 AHU-2 55 0 0.25

VAV2-15 6 AHU-2 210 0 0.25

VAV2-16 6 AHU-2 100 0 0.25

VAV2-17 6 AHU-2 100 0 0.25

VAV2-18 6 AHU-2 55 0 0.25

VAV2-19 6 AHU-2 55 0 0.25

VAV2-20 6 AHU-2 55 0 0.25

VAV2-21 6 AHU-2 55 0 0.25

VAV2-22 6 AHU-2 85 0 0.25

VAV2-23 6 AHU-2 85 0 0.25

VAV2-24 6 AHU-2 55 0 0.25

VAV2-25 6 AHU-2 85 0 0.25

VAV2-26 6 AHU-2 85 0 0.25

VAV2-27 6 AHU-2 85 0 0.25

VAV2-28 6 AHU-2 140 0 0.25

VAV2-29 8 AHU-2 440 0 0.25

VAV2-30 6 AHU-2 220 0 0.25

VAV2-31 12 AHU-2 1160 0 0.25

VAV2-32 10 AHU-2 760 0 0.25

VAV2-34 6 AHU-2 50 0 0.25

VAV2-35 8 AHU-2 420 0 0.25

VAV2-36 8 AHU-2 285 0 0.25

VAV2-37 8 AHU-2 500 0 0.25

VAV2-38 8 AHU-2 510 0 0.25

VAV2-39 6 AHU-2 135 0 0.25

VAV2-40 10 AHU-2 720 0 0.25

VAV2-41 6 AHU-2 195 0 0.25

VAV2-42 6 AHU-2 195 0 0.25

VAV2-43 8 AHU-2 440 0 0.25

VAV2-44 6 AHU-2 300 0 0.25

VAV2-45 8 AHU-2 350 0 0.25

VAV2-46 8 AHU-2 450 0 0.25

VAV2-47 10 AHU-4 770 0 0.25

VAV2-56 6 AHU-4 290 0 0.25

VAV2-57 8 AHU-4 365 0 0.25

VAV2-58 6 AHU-4 140 0 0.25

VAV2-59 8 AHU-4 580 0 0.25

VAV2-60 6 AHU-4 90 0 0.25

VAV2-61 6 AHU-4 150 0 0.25

VAV2-63 10 AHU-4 790 0 0.25

VAV3-01 12 CFR BUILDING 350 0 0.25

VAV3-02 8 CFR BUILDING 310 0 0.25

VAV3-03 10 CFR BUILDING 690 0 0.25

VAV3-04 6 CFR BUILDING 150 0 0.25

VAV3-05 6 CFR BUILDING 120 0 0.25

VAV3-06 6 CFR BUILDING 60 0 0.25

VAV3-07 6 CFR BUILDING 60 0 0.25

VAV3-08 6 CFR BUILDING 60 0 0.25

VAV3-09 6 CFR BUILDING 60 0 0.25

VAV3-10 6 CFR BUILDING 80 0 0.25

VAV3-11 6 CFR BUILDING 165 0 0.25

VAV3-13 6 CFR BUILDING 60 0 0.25

VAV3-14 6 CFR BUILDING 120 0 0.25

VARIABLE AIR VOLUME BOX SCHEDULE

MARK

UNIT

SIZE AHU SERVED

MAX

AIRFLOW

(CFM)

MIN

AIRFLOW

(CFM)

MAX AIR

PRESSURE

DROP (IN.

W.C.)

VAV1-01 8 AHU-1 515 0 0.25

VAV1-02 6 AHU-1 125 0 0.25

VAV1-03 10 AHU-1 820 0 0.25

VAV1-04 6 AHU-1 350 0 0.25

VAV1-05 6 AHU-1 115 0 0.25

VAV1-06 10 AHU-1 835 0 0.25

VAV1-07 8 AHU-1 715 0 0.25

VAV1-08 10 AHU-1 780 0 0.25

VAV1-09 6 AHU-1 140 0 0.25

VAV1-10 6 AHU-1 80 0 0.25

VAV1-11 6 AHU-1 200 0 0.25

VAV1-12 6 AHU-1 140 0 0.25

VAV1-13 6 AHU-1 60 0 0.25

VAV1-14 12 AHU-1 830 0 0.25

VAV1-15 12 AHU-1 830 0 0.25

VAV1-16 6 AHU-1 40 0 0.25

VAV1-17 6 AHU-1 200 0 0.25

VAV1-18 6 AHU-1 360 0 0.25

VAV1-19 6 AHU-1 80 0 0.25

VAV1-20 8 AHU-1 435 0 0.25

VAV1-21 6 AHU-1 250 0 0.25

VAV1-22 6 AHU-1 170 0 0.25

VAV1-23 6 AHU-1 235 0 0.25

VAV1-24 6 AHU-1 120 0 0.25

VAV1-25 6 AHU-1 140 0 0.25

VAV1-26 6 AHU-1 385 0 0.25

VAV1-31 8 AHU-4 345 0 0.25

VAV1-32 10 AHU-4 675 0 0.25

VAV1-33 6 AHU-4 365 0 0.25

VAV1-34 6 AHU-4 280 0 0.25

VAV1-35 6 AHU-4 260 0 0.25

VAV1-37 6 AHU-4 165 0 0.25

VAV1-38 6 AHU-4 360 0 0.25

VAV1-39 8 AHU-4 610 0 0.25

VAV1-40 6 AHU-4 90 0 0.25

VAV1-41 6 AHU-4 320 0 0.25

VAV1-42 8 AHU-4 720 0 0.25

VAV1-43 6 AHU-4 80 0 0.25

VAV1-48 8 AHU-3 480 0 0.25

VAV1-49 8 AHU-3 660 0 0.25

VAV1-50 6 AHU-3 100 0 0.25

VAV1-51 8 AHU-3 680 0 0.25

VAV1-52 8 AHU-3 200 0 0.25

VAV2-01 6 AHU-2 105 0 0.25

VAV2-02 6 AHU-2 85 0 0.25

VAV2-03 6 AHU-2 85 0 0.25

VAV2-04 6 AHU-2 85 0 0.25

VAV2-05 6 AHU-2 85 0 0.25

VAV2-06 6 AHU-2 105 0 0.25

VAV2-07 6 AHU-2 75 0 0.25

VAV2-08 6 AHU-2 55 0 0.25

VAV2-09 6 AHU-2 55 0 0.25

VAV2-10 6 AHU-2 55 0 0.25

VAV2-11 6 AHU-2 75 0 0.25

VAV2-12 6 AHU-2 55 0 0.25

VARIABLE AIR VOLUME BOX SCHEDULE NOTES:

1. VAV3-01 THRU VAV3-14 ARE FOR BID OPTION 1.

2. PROVIDE HOT WATER HEATING COIL FOR VAV3-05 TO PROVIDE 80°F LAT.

GENERAL NOTES - SCHEDULES

ALL EQUIPMENT SELECTED AT 6350 FT. ELEVATION ABOVE SEA LEVEL

VEHICLE EXHAUST FAN SCHEDULE

MARK LOCATION SERVICE UNIT TYPE

TOTAL

AIR (CFM)

E.S.P. (IN.

W.C.)

ELECTRICAL

DRIVE

TYPE FAN HP PHASE VOLTAGE

VEF-1 HELO 197 - G-4 BEARCAT BACKWARD INCLINED CENTRIFUGAL 700 4.6 DIRECT 1.5 1 208

VEF-2 HELO 197 - G-4 BEARCAT BACKWARD INCLINED CENTRIFUGAL 700 4.6 DIRECT 1.5 1 208

VEF-3 HELO 197 - G-4 BEARCAT BACKWARD INCLINED CENTRIFUGAL 700 4.6 DIRECT 1.5 1 208

VEF-4 HELO 197 - G-4 BEARCAT BACKWARD INCLINED CENTRIFUGAL 700 4.6 DIRECT 1.5 1 208

SOLDERING EXHAUST FAN SCHEDULE

MARK LOCATION SERVICE UNIT TYPE

TOTAL

AIR

(CFM)

E.S.P.

(IN.

W.C.)

ELECTRICAL

DRIVE

TYPE

FAN

HP FLA PHASE VOLTAGE

SEF-1 HELO 183 - AVIONICS WALL MOUNTED 180 2.7 DIRECT 0.75 13.8 1 120

SEF-2 HELO 189 - GENERAL MAINTENANCE WALL MOUNTED 180 2.7 DIRECT 0.75 13.8 1 120

LOUVER DAMPER SCHEDULE

MARK SERVICE

AIRFLOW

(CFM)

VELOCITY

(FPM)

MOTORIZED DAMPER

ELECTRICAL

VOLTAGE POWER PHASE

L-1 OUTSIDE AIR 6400 700 24 V 45 W 1

L-2 OUTSIDE AIR 2100 500 24 V 45 W 1

L-3 OUTSIDE AIR 3595 700 24 V 45 W 1

L-4 OUTSIDE AIR 1485 500 24 V 45 W 1

L-5 OUTSIDE AIR 840 500 24 V 45 W 1

L-6 OUTSIDE AIR 830 500 24 V 45 W 1

L-7 OUTSIDE AIR 1325 500 24 V 45 W 1

L-10 EXHAUST 3595 750 24 V 45 W 1

L-11 EXHAUST 1485 750 24 V 45 W 1

L-12 EXHAUST 840 750 24 V 45 W 1

ROOF HOOD SCHEDULE

Mark SERVICE TYPE

THROAT

DIMS

AIRFLOW

(CFM)

FREE AREA

(SF)

STATIC

PRESSURE

(IN. W.G.)

RH-2 AHU-2 INTAKE ROOF HOOD 54x54 9700 20.25 0.05

RH-3 ELECTRICAL ROOM INTAKE ROOF HOOD 30"Ø 2615 5.03 0.07

RH-4 2ND FLOOR MECH ROOM INTAKE ROOF HOOD 30"Ø 2770 5.03 0.08

RH-5 CRASH RESCUE INTAKE ROOF HOOD 24"Ø 1285 3.24 0.03

RH-6 CFR MECH ROOM INTAKE ROOF HOOD 20"Ø 1105 2.25 0.04

RH-7 CFR ELECTRICAL ROOM INTAKE ROOF HOOD 24"Ø 1590 3.24 0.04

RH-8 2ND FLOOR MECH ROOM EXHAUST ROOF HOOD 24"Ø 2770 3.24 0.09

RH-9 COMPRESSOR ROOM EXHAUST ROOF HOOD 15"Ø 830 1.12 0.06

RH-10 RELIEF ROOF HOOD 54x54 8150 20.25 0.04

RH-11 RELIEF ROOF HOOD 54x54 8150 20.25 0.04

RH-12 CFR RELIEF ROOF HOOD 28x28 2600 5.44 0.05

RH-13 SIM COMM ROOM INTAKE ROOF HOOD 10x10 160 0.37 0.03

ROOF HOOD SCHEDULE NOTES:

1. RH-5, 6, 7, AND 12 ARE FOR BID OPTION 1.

2. PROVIDE 24" MANUFACTURER SUPPLIED ROOF CURB

3. PROVIDE BIRD SCREEN ON OPENINGS.

LOUVER SCHEDULE NOTES:

1. REFER TO ARCHITECTURAL FOR LOUVER SIZE.

VEHICLE EXHAUST FAN SCHEDULE NOTES:

1. PROVIDE A MINIMUM 8" Ø HOSE AND SPRING OPERATED HOSE REEL.

2. FOR VEF-1 THROUGH VEF-4 PROVIDE A Y-ADAPTOR FOR DUAL EXHAUST CONNECTION.

3. EXHAUST FAN SHALL BE DIRECT MOUNTED TO HOSE REEL.

4. PROVIDE MINIMUM 20 FT LONG HOSE. COORDINATE HOSE LENGTH WITH HOSE REEL LOCATION.

FAN POWERED TERMINAL UNIT (HOT WATER HEAT) SCHEDULE

Mark

INLET

SIZE

AHU

SERVED

MAX

AIRFLOW

(CFM)

MIN

AIRFLOW

(CFM)

FAN E.S.P.

(IN. W.C.)

ELECTRICAL HEATING

RADIATED

NC

DISCHARGE

NCFAN HP MCA PHASE VOLTAGE AIRFLOW

CAPACITY

(MBH)

EWT

(°F)

LWT

(°F)

FLOW

(GPM)

MAX WATER

PRESSURE

DROP (FT)

MAX

ROWS

FTU-1 6 AHU-2 500 250 0.28 0.17 2.9 1 120 500 3.3 140 115 0.8 0.10 1 22 24

FTU-2 6 AHU-2 500 250 0.28 0.17 2.9 1 120 500 3.3 140 115 0.8 0.10 1 22 24

FTU-3 10 AHU-4 1400 1400 0.32 0.33 10.6 1 120 770 5 140 97 0.8 0.17 1 31 26

FTU-4 12 AHU-4 1525 750 0.33 0.33 10.6 1 120 1525 18 140 96 0.8 0.17 1 32 27

FTU-5 12 AHU-4 1525 750 0.33 0.33 10.6 1 120 1525 18 140 96 0.8 0.17 1 32 27

FTU-6 8 AHU-5 720 360 0.3 0.25 5 1 120 720 9.5 140 112 0.8 0.10 1 27 20

FTU SCHEDULE NOTES:

1. MOTOR SHALL BE ECM RATED

SOLDERING EXHAUST FAN SCHEDULE NOTES:

1. PROVIDE WITH INTEGRAL DISCONNECT AND STARTER, CONSOLIDATED WORKBENCH AND MANUFACTURER'S HAND SWITCH.

A

M

R E

V

IS

IO

N

S

-0

-2

MAU-2

A

EA

EA

OA

RADIANT FLOOR

LOCATED ON LOW ROOF

EF-9

REFER TO A7/M-713 FOR

CONFIGURATION DETAIL

PERSONNEL

DOORS

QTY. 2

O A

M M

18"

ROLL UP DOOR

QTY. 3

OA

COx

NOx

HOSE STORAGE

EQUIP MAINT

PPE

50 CFM

70 CFM

45 CFM

EA

EA

EA

OA

LALA

SOLAR

WALL

POA

MODE

PURGE

MIN

MAU

EF-9

AIRFLOWS (CFM)

EA

EF-12

M

NOTE:

1. MINIMUM DESIGN AIRFLOWS SHOWN.

EF-12

SA SUPPLY AIR

LEAKAGE AIR

OUTSIDE AIR

RETURN AIR

EXHAUST AIR

PREHEATED OUTSIDE AIR

VEHICLE EXHAUST AIR

CARBON MONOXIDE

NITROGEN OXIDE

MOTORIZED DAMPER

FLOW SENSOR

THERMOSTAT

LA

OA

RA

M

F

T

LEGEND

EA

POA

VEA

CO

NO

EA

EF

O A

M M

OA

E A

C

F M

C

F M

HS

BRODIE B. B. HEFLIN

OF TEXASS

TATE

ALNOI

SS

E

F O

R P

ENG

IN

E E

R

NSEDECI

L 106046

US Army Corps of Engineers Omaha District ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

A F

-1

-0

-W F

R

M

A R

C H

C H

O F

F F

IL

E

N A

M E

O M

A H

A D

IS

T

R

A H

A

N E

B R

A S

K A

F Y

H

E L

O /T

R F

/M A

IN

T

E N

A N

C E

F A

C

IL

IT

Y

P R

O J E

C T

N U

M B

E R

G

H L

N A

F E

W A

R R

E N

A F

B

W Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t

F o rt

W o rt h

T X

READY-TO-ADVERTISE (RTA) DESIGN

TEXAS REGISTERED

ENGINEERING FIRM F-2966

M-704

A

IR

F L O

W D

IA

G

R A

M S

B B

S /R

C

B B

S /R

C

B H

F E

-G

H L N

A M

-7

NTSA6

CFR VEHICLE BAY AIRFLOW DIAGRAM

NTSA1

SIM COMM ROOM - CLEAN AGENT EXHAUST AIRFLOW DIAGRAM

A

M

R E

V

IS

IO

N

S

-0

-2

T

T

T

T

S

S3

H T

T

T

T

LCS

NLP11

NHL11

ATS-1

SHL12

T-SD2

NHSIM

SSB

ATS-2

LCP11

NSB

UH-4

T-NP11

RCP11

NLSIM

SLCP12

SLD2

MSE

21 22

A

B

C

E

F

H

G

LO

AD

B

AN

K

ECB 1E

ECB TB2

ECB TB1

ECB 2O

SHL1

IN-FLOOR

PIT

T-NP12

NLP12

FCU-1

RCP12

Z

AA

SHL11

SLCP11

NHL21

T-NP22

NLP22A

NLP22B

LCP21

FCU-11

W

RCP22A

RCP22B

8 9 10

Q.7

R

R.5

SLCP21 SHL21

T-SP21

SLP21

R.6

W FCU-4

ELEV (1)

K

J

W

D2

D2

GFI/WP

GFI/WP

SLP13:27

SLP13:24

ELEV (2)222

ELEVATOR

ELEV EQUIP

SLP13:7253

SLP13:20

SLP13:22

WP

ELEV (3)

SHE11

HUM-1

AIR CC

AIR CCR 1

AIR CSS 1064

T-SP11

SLP11

LL

MM

AIR CSS 2

AIR CCR 2

UH-2

AIR LCP

T-NP21 RCP21A

NLP21A

NLP21B

RCP21B

L

L.4

M

21 22 23 24 25 26

3'

4" B

FG

201201

3'

" B

FG

4'

6" B

FG

205204

203203

4'

/4

3'

4"

3'

" B

FG

L

L.4

SLP15SLP13

RCP13

NLP13

T-NP13

NHD1 LCP13NHL13

SRCP15

NLP13:37

NLP13:39

02 4 8134

SCALE: 1/4"=1'-0"

US Army Corps of Engineers Omaha District ®

SHEET

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

2x

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

D R

AW

IN

G C

O D

E.

AF

1-

-0

-W

F2

1R

M

A R

C H

C . H

O

FF

FI

LE

N

AM

E:

O M

AH

A

D

IS

TR

IC

T O

M

AH

A, N

EB

R

AS

KA

FY

H

EL

O /T

R F/

M

AI

N

TE

N

AN

CE

F

AC

IL

IT

Y

PR

O

JE

C

T N

UM

B

ER

: G

H

LN

A

FE

W

AR

R

EN

A

FB

, W

Y

JA

C

O

BS

E N

G

IN

EE

R

IN

G

G R

O U

P

IN

C

M ai n St re et

Fo rt

W or th , T

X

READY-TO-ADVERTISE (RTA) DESIGN

E-401

EN

LA

R G

ED

P

LA

N

S

C . T

R U

SS

EL

L

C . T

R U

SS

EL

L

L.

J.

D

AV

IS

FE

-G H

LN

3 0

AE

-4

1/4" = 1'-0"A3 ENLARGED PLAN - ELEC 166

GENERAL NOTES - POWER

A REFER TO SHEET E-001 FOR GENERAL NOTES,

SYMBOLS AND ABBREVIATIONS.

B REFER TO DETAIL A1, SHEET E-506 FOR DEVICE

MOUNTING HEIGHTS.

C PROVIDE RECEPTACLES AND FIXTURES IN CLASS 1,

DIVISION 2 SPACES MOUNTED AT 18" AFF TO BOTTOM

OF FIXTURE UNLESS OTHERWISE NOTED.

D PROVIDE ALL ELECTRICAL EQUIPMENT IN HANGAR

BAYS IN NEMA 3R ENCLOSURES UON. PROVIDE NEMA

4X FOR ALL EQUIPMENT LOCATED IN AIRCRAFT WASH

BAY. ALSO PROVIDE 18" PEDESTALS FOR FLOOR

MOUNTED EQUIPMENT WHERE NECESSARY TO

CONFORM WITH NEC HAZARDOUS AREA

CLASSIFICATION REQUIREMENTS.

E REFER TO EP130-EP143 FOR ADDITIONAL EQUIPMENT

CONNECTION INFORMATION.

F REFER TO GI005 FOR NEC CLASSIFIED HAZARDOUS

AREA PLANS.

G CONTROLLED RECEPTACLES TO UTILIZE CENTRALIZED

RECEPTACLE CONTROL PANEL RELAY SYSTEM IN ELEC

ROOMS. PROVIDE RECEPTACLE CONTROL PANELS AS

NECESSARY TO ACHIEVE PERFORMANCE INDICATED

ON PLANS. RE: E-519 FOR RCP/LCP WIRING DIAGRAM.

1/4" = 1'-0"C1 ENLARGED PLAN - ELEC 137

1/4" = 1'-0"D1 ENLARGED PLAN - ELEC 228

1/4" = 1'-0"F6 ENLARGED PLAN - ELEVATOR

1/4" = 1'-0"A1 ENLARGED PLAN - LIGHTING VAULT 196

KEYNOTES

062 PROVIDE AIRFIELD LIGHTING CONTROL PANEL IN NEMA 3R ENCLOSURE. RE:

E-704 FOR ONE LINE DIAGRAM.

063 PROVIDE AIRFIELD CONSTANT CURRENT REGULATOR IN NEMA 3R

ENCLOSURE WITH INTEGRAL HMI SCREEN. RE: E-702 & E-704 FOR ONE LINE

DIAGRAMS.

064 PROVIDE AIRFIELD CIRCUIT SELECTOR SWITCH IN NEMA 3R ENCLOSURE. RE:

E-704 FOR ONE LINE DIAGRAM.

065 PROVIDE AIRFIELD CUTOUT CABINET IN NEMA 3R ENCLOSURE WITH

APPROXIMATE DIMENSIONS OF 36" H X 24" W X 10" D.

099 MAINTAIN A MINIMUM 3" CONCRETE ENCASEMENT AND 3" SEPARATION

BETWEEN ALL DUCTS. COORDINATION PENETRATIONS WITH STRUCTURAL

FOUNDATION BEFORE POURING CONCRETE. REFER TO STRUCTURAL

DETAILS. COORDINATION UTILITY CROSSINGS WITH SITE CIVIL CONTRACTOR

TO MAINTAIN MINIMUM 3' BURIAL DEPTH TO TOP OF CONCRETE.

189 MOUNT 4'-6" ABOVE PIT FLOOR AND EVERY 10' ABOVE THAT FOR HEIGHT OF

ELEVATOR SHAFT. MOUNT TOP FIXTURE TO CEILING. COORDINATE

INSTALLATION WITH ELEVATOR INSTALLER.

201 TRANSFORMER FIRE PUMP TAP BOX FEEDER. RE: E-701 AND E-702 FOR

CABLE AND CONDUIT SIZING.

202 TRANSFORMER MSE FEEDER. RE: E-701 FOR CABLE AND CONDUIT SIZING.

203 GENERATOR FIRE PUMP TAP BOX FEEDER. RE: E-702 FOR CABLE AND

CONDUIT SIZING.

204 GENERATOR ATS 1 FEEDER. RE: E-702 FOR CABLE AND CONDUIT SIZING.

205 GENERATOR ATS 2 FEEDER. RE: E-702 FOR CABLE AND CONDUIT SIZING.

206 TRANSFORMER ATS 2 FEEDER. RE: E-701 AND E-702 FOR CABLE AND

CONDUIT SIZING.

220 MOUNT THREE WAY SWITCH INSIDE THE ELEVATOR CHASE AT 4' ABOVE

ELEVATOR LANDING ON BOTH LEVELS. COORDINATE INSTALLATION OF

SWITCH SO THAT IT IS LOCATED ADJACENT TO THE HOISTWAY ACCESS

LADDER.

221 MOLDED CASE CIRCUIT BREAKER IN NEMA 1 ENCLOSURE, 20A, 1 POLE, 120V

FOR ELEVATOR CAB LIGHTING AND IN-CAB CONVENIENCE RECEPTACLE. RE:

E-602 FOR CIRCUITING INFO. ALSO PROVIDE PERMANENTLY ATTACHED SIGN

WHICH READS 'WARNING PARTS OF THE CONTROLLER ARE NOT

DE-ENERGIZED BY THIS SWITCH.' BREAKER HANDLE MUST BE CAPABLE OF

BEING LOCKED IN THE OPEN POSITION ONLY.

222 MOLDED CASE CIRCUIT BREAKER IN NEMA 1 ENCLOSURE, 20A, 1 POLE, 120V

FOR ELEVATOR CAB HVAC. RE: E-602 FOR CIRCUITING INFO. BREAKER

HANDLE MUST BE CAPABLE OF BEING LOCKED IN THE OPEN POSITION ONLY.

223 MOLDED CASE CIRCUIT BREAKER IN NEMA 1 ENCLOSURE, 125A, 3 POLE, 480V

FOR ELEVATOR MOTOR. PROVIDE WITH SHUNT TRIP ACTIVATION.

COORDINATE WITH FIRE ALARM FOR ACTIVATION OF ELEVATOR SHUNT TRIP

WITH ALARM ACTIVATION. RE: E-602 FOR CIRCUITING INFO. PROVIDE

PERMANENTLY ATTACHED SIGN IDENTIFYING THE LOCATION OF THE SUPPLY

SIDE OVERCURRENT PROTECTIVE DEVICE. ALSO PROVIDE PERMANENTLY

ATTACHED SIGN WHICH READS "WARNING PARTS OF THE CONTROLLER ARE

NOT DE-ENERGIZED BY THIS SWITCH." BREAKER HANDLE MUST BE CAPABLE

OF BEING LOCKED IN THE OPEN POSITION ONLY.

224 LOCATE RECEPTACLE INSIDE OF ELEVATOR CHASE 3' ABOVE ELEVATOR PIT

FLOOR IN WEATHERPROOF ENCLOSURE. TYPICAL OF TWO.

225 ELEVATOR CAB TELEPHONE. COORDINATE WITH ELEVATOR SUPPLIER FOR

REQUIREMENTS.

253 PROVIDE A TWIST-LOCK SIMPLEX RECEPTACLE WITH PILOT LAMP TO VERIFY

CIRCUIT IS ENERGIZED FOR SUMP PUMP, NO GFI OR GFCI PROTECTION.

MOUNT 5' ABOVE PIT FLOOR.

254 PROVIDE A SIMPLEX RECEPTACLE 3' ABOVE PIT FLOOR WITH WEATHER

RESISTANT ENCLOSURE AND WET LOCATION WIRING FOR SCAVENGER

PUMP. COORDINATE LOCATION WITH ELEVATOR SUPPLIER. COORDINATE

PROTECTION AND WIRING WITH PUMP MANUFACTURER.

262 PROVIDE DEDICATED LIGHTING CONTROL SYSTEM SERVER WITH ALL

ASSOCIATED PERIPHERALS. COORDINATE REQUIREMENTS WITH LIGHTING

CONTROL SYSTEM PROVIDER.

320 PROVIDE ALL NAMEPLATES IN ACCORDANCE TO THE SPECIFICATIONS. IN

ADDITION, PROVIDE PLACARD…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .