Tank Top in way of Trunnion Room.pdf
PDF 219 KB Posted
- Attached to
- FY24 Yaquina Overhaul Solicitation
- Solicitation number
- W9127N23B0014
About this file
This document contains an ultrasonic thickness measurement report for the tank top in way of the trunnion room of the dredge Yaquina. Key details include measurements taken at 112 locations on the tank top with substantial and excessive wastage percentages noted in blue and red. Substantial wastage was found at 18.75% of readings while excessive wastage was found at 25% of readings. A spreadsheet provides a complete list of readings and wastage percentages. Relatedly, solicitation number W9127N23B0014 seeks offers for overhaul of the dredge Yaquina to be awarded by the US Army Corps of Engineers Engineering District Portland.
View the file
Other files
Show 40 more
Latest 50 of 119 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M ou nt
M ou nt
Manhole
.378 .311
.358 .338
.361
.343 .315
.369
.351
.342
.375
.351
.353
.331
.364
.358.256.360
.331
.299
.253 .318 .208.258
.372
.290
.277 .238
.248 .259
.336.311
.362
.212 .227
.342 .282 .239
.267
.275
.308
.319
.354
.367
.375
.325
.381
.389
.321 .215
.338
.348
.356
.354
.352
.295
.221
.211
.218 .203
.211 .238
.226
USACE Dredge "YAQUINA" Ultrasonic Thickness Measurements of Tank Top in way of Trunnion Room
Drawing 21
Manhole
M ou nt
M ou nt
.344 .344 .344 .352 .333
.243 .287
.299
.380
.368 .345
.310 .325
.362 .335
.340
.358
.361
.358
.339
.348
.371
.351
Forward
Port SideStbd. Side
Note: Substantial wastage [18.75%] readings are shown in (blue) and excessive wastage [25%] readings are shown in (red).
See following spreadsheet for a complete list of readings and wastage.
Note: Blue percentages show Substantial wastage. Red percentages show excessive wastage.
info@certifiedndt.com
(253-952-2337
Report: 53303 Date: 3/3/2023
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 .375 .333 .243 .287 .299 .380 .351 .352 .368 .344 .344 .345 .358 .344 .335 .340
%Wastage 11.20% 35.20% 23.47% 20.27% 0.00% 6.40% 6.13% 1.87% 8.27% 8.27% 8.00% 4.53% 8.27% 10.67% 9.33% .375 .361 .362 .325 .339 .358 .310 .348 .371 .339
%Wastage 3.73% 3.47% 13.33% 9.60% 4.53% 17.33% 7.20% 1.07% 9.60% .375 .369 .315 .342 .375 .351 .381 .351 .325 .343 .361 .358 .364 .331 .353 .375
%Wastage 1.60% 16.00% 8.80% 0.00% 6.40% 0.00% 6.40% 13.33% 8.53% 3.73% 4.53% 2.93% 11.73% 5.87% 0.00% .375 .318 .208 .267 .256 .253 .258 .239 .275 .308 .354 .367 .338 .282 .319 .358
%Wastage 15.20% 44.53% 28.80% 31.73% 32.53% 31.20% 36.27% 26.67% 17.87% 5.60% 2.13% 9.87% 24.80% 14.93% 4.53% .375 .342 .348 .356 .354 .299 .248 .336 .259 .362 .212 .227 .218 .221 .352 .311
%Wastage 8.80% 7.20% 5.07% 5.60% 20.27% 33.87% 10.40% 30.93% 3.47% 43.47% 39.47% 41.87% 41.07% 6.13% 17.07% .375 .311 .389 .215 .203 .211 .238 .226 .295 .211 .378 .360 .331 .321 .338 .321
%Wastage 17.07% 0.00% 42.67% 45.87% 43.73% 36.53% 39.73% 21.33% 43.73% 0.00% 4.00% 11.73% 14.40% 9.87% 14.29% .375 .290 .277 .372 .238 .294
%Wastage 22.67% 26.13% 0.80% 36.53% 21.73%
Tank Top 25%
USACE Dredge "YAQUINA"
Ultrasonic Thickness Measurements of: Tank Top in way of Trunnion Room [Drawing 21]
Structure Location Number Side Structural
Member Max. Allow.
Wastage Max.
Dim.
Nominal Thickness
Readings Avg./ % Loss
.281Trunnion Room 1
.281
Trunnion Room 1 [cont.] Port Tank Top 25% .281
Trunnion Room 2 Stbd. Tank Top 25%
Port
.281
Trunnion Room 2 [cont.] Stbd. Tank Top 25% .281
Trunnion Room 3 Stbd. Tank Top 25%
.281
Trunnion Room 2 [cont.] Stbd. Tank Top 25% .281
Trunnion Room 2 [cont.] Stbd. Tank Top 25%
File details come from the government source that posted it. Updated .