P7555 - Dredge Yaquina Launch Final.pdf

PDF 5 MB Posted

Attached to
FY24 Yaquina Overhaul Solicitation
Solicitation number
W9127N23B0014
Issued by

About this file

This document contains a report from an inspection of the dredge Yaquina Launch conducted on behalf of the U.S. Army Corps of Engineers. The inspection included a visual examination of the hull and structural stiffening below the waterline, as well as liquid penetrant testing and positive material identification at various locations. The inspection found indications of pitting, fractures, and surface roughness. Liquid penetrant testing revealed fractures in the bottom plate, rudder stock hull penetration, and a frame weld. Positive material identification determined the vessel is constructed of aluminum alloy 5086 in all locations tested.

Also included is a solicitation from the Department of the Army Corps of Engineers Engineering District Portland for overhaul work on the dredge Yaquina in fiscal year 2024. No other details are provided on the products, services, pricing, or terms required under the solicitation.

View the file

Other files

File Type Posted
C.04_FormalAbstractOfOffers7N23B0014.pdf PDF
C.04_BidRoster7N23B0014.pdf PDF
B.08 W9127N23B0014 Yaquina Overhaul Amendment 0003.pdf PDF
B.08 Price List Amendment 0003.xlsx XLSX spreadsheet
Port Sewage Flat Tank Top fR 94 95.pdf PDF
Furuno 2827 Radars.pdf PDF
VD-TM-91721User Op.Manual.pdf PDF
Y-2232-18 Arrgt Details of Bow Thruster Instl.pdf PDF
Bottom plating within 4th strake from keel.pdf PDF
Furuno GP-170.pdf PDF
Furuno GP-170 AIS.pdf PDF
Ned-deck Marine O M Davit SCH rev E 14-12-2010.pdf PDF
Tank Top in way of Trunnion Room.pdf PDF
DT50-55 Tech Manual 80-677.pdf PDF
Dredge Yaquina - TAB Report March 2023.pdf PDF
B.08 W9127N23B0014 Yaquina Overhaul Amendment 0002.pdf PDF
Furuno FE-700 Echo Sounder.pdf PDF
GX5500S.pdf PDF
LIPS-A004654.pdf PDF
Furuno RD-30 Repeater.pdf PDF
Y-2470-4_Installation_of_New_Hopper_Distribution_System.pdf PDF
Bottom plating in Steering Flat at port side aft of frame 88 .pdf PDF
Y-2496-3 Hyd Cylinders Ovfl Trough Hopper Doors.pdf PDF
95340 Swell Compensator Cylinder.pdf PDF
Y-2496-2 Arrgt Details Hopper Doors Operating Gear.pdf PDF
19731_Longitudinal Stiffeners.pdf PDF
19731 REV 06 Sent to cust. 4.12.21.pdf PDF
Y-1032-16 Sheets 1 to 6.pdf PDF
Hundested 1-022-021126-2 MP700-CPG120 Installation Unit 6331-G1178.pdf PDF
Red Hawk FA-101 Fire Alarm System FAS Layout.pdf PDF
5241127.pdf PDF
Y-2636-1 Shaft Struts.pdf PDF
Y-2232-44 Seachests.pdf PDF
Y-2274-1 Detail 15-A Rudder Seal Ring.pdf PDF
D-1441-1.PDF PDF
Hundested 0-002-020932-2 MP700 Propeller Hoved Samling.pdf PDF
5241115 Trunnion.pdf PDF
Red Hawk FA-000 Fire Alarm System General Notes.pdf PDF
Y-3874-3 DIAGRAM Bilge and Ballast System.pdf PDF
Y-3872-4 Arrangement Firemain System.pdf PDF
Y-3874-4 Arrangement Bilge and Ballast System.pdf PDF
1788 0878 Stuffing Box female recess.pdf PDF
12V2000_P82_operating instructions.pdf PDF
Y-2636-2 Shafting Arrangement.pdf PDF
X-1441-2 Rev G.pdf PDF
Y-3872-3 DIAGRAM Firemain System.pdf PDF
Y-3872-5 DIAGRAM Sea Water Circ System.pdf PDF
Hundested 2-140-021135-1 MP700-CPG120 Flange Coupling Assembly.pdf PDF
Y-2274-1 Rudders.pdf PDF
Y-3872-6 Sea Water Argmt.pdf PDF
Show 40 more

Latest 50 of 119 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Specialists in Nondestructive Examination

Seattle: 3229 S. 148 th Street, SeaTac, WA 98168 Phone: 206/766-8180 Fax: 206/766-8186

Portland: 10521 N. Lombard Street, Portland, OR 97203 Phone: 503/283-2668 Fax: 503/283-7656 Oakland: 2900 Main St., Suite 3201, Alameda, CA 94501 Phone: 510/748-0964 Fax: 510/748-9874

Los Angeles: 10600 Pioneer Blvd., Unit A, Santa Fe Springs, CA 90670 Phone: 562/944-3166 Fax: 562/944-3114 San Diego: 7030 Alamitos Ave., Suite B, San Diego, CA 92154 Phone: 619/512-5858

Houston: 1146 Sheffield Blvd., Suite O, Houston, TX 77015 Phone: 832/767-3238 www.iinspect.com II Report Cover – Page 1 of 3

DREDGE YAQUINA LAUNCH

Hull Inspection

October 2021

Seattle Portland Los Angeles San Diego Houston 3229 S. 148 th St. 10521 North Lombard St. Corporate Headquarters 2704 Transportation Ave., Unit C 1146 Sheffied Blvd., Suite O

SeaTac, WA 98168 Portland, OR 97203 10600 Pioneer Blvd., Unit A National City, CA 91950 Houston, TX 77015

(206) 766-8180 Fax (206) 766-8186 (503) 283-2668 Fax (503) 283-7656 Santa Fe Springs, CA 90670 (619) 512-5858 Fax (619) 512-5859 (832) 767-3238 seattle@iinspect.com portland@iinspect.com (562) 944-3166 Fax (562) 944-3114 sandiego@iinspect.com houston@iinspect.com la@iinspect.com www.iinspect.com

QA Manager/ Operations Manager Review

Signature Date

All drawings, specifications, and copies thereof furnished by International Inspection LLC (hereafter, “the Work Product”) are and shall remain the property of International Inspection LLC. The Work Product is to be used only with respect to work on the vessel/project listed above (hereafter, “The Project”) and is not to be used on any other project or delivered to any person or entity not directly involved with The Project. Submission or distribution of the Work Product to meet official regulatory requirements for other purposes in connection with The Project is not to be construed as publication in derogation of International Inspection LLC’s common law copyright or other reserved rights to Work Product.

Copyright (c) 2021 International Inspection LLC drosian Daniel C Rosian drosian Text Box 10/22/2021 drosian Text Box

Seat t le Por t land Oak land Los Ange les San Diego Hous ton

Specialists in Nondestructive Examination www.iinspect.com II Report Cover – Page 3 of 3

Visual, Liquid Penetrant, and Positive Material Identification testing methods were performed for the U.S, Army Corps of Engineers on the vessel Yaquina Launch on October 19, 2021 at Terminal 2 in Portland, Oregon. The owners were represented by Mr. Sam Repman. The survey was conducted by International Inspection personnel.

EXTENT OF SURVEY

Visual inspection of hull and structural stiffening below water line for in service related suspect areas. Liquid Penetrant testing was utilized to identify the area of extent in the locations deemed to qualify as suspect areas. Positive Material Identification (PMI) was performed to identify material used during fabrication.

RESULTS OF SURVEY

The results are shown within the following report.

Respectfully submitted, Michael Fiskum Technician P7555

Client

Project fc

Inspector (Print Name)

203199ABC

8/26/2021

Fracture in bottom plate

Fracture at rudder stock hull penetration

Client Information Only

VISUAL INSPECTION REPORT

Page

Date/Time

Accept RejectIndication # Location

Pitting in base material1

Specification

Acceptance Criteria

U.S. Army Corps of Engineers

Description

We hereby certify that the above information was examined in accordance with the specified requirements, and that the results indicated are the accurate interpretation of the undersigned inspector to the best of his/her knowledge, ability and integrity.

Calib Due 2/26/2021

Light Meter Reading 800

Indication not accessible due to dock cradle

Stbd Side Shell

Stbd Btm. Plt.

Port Btm. Plt.

Port Btm. Plt.

Fracture in frame weld

Frame M

Report No.

Stbd Bow

Stbd Bow 0

P7555 10/19/21

7RevisionII-41-6002-B

WO# G222-9637 Dredge Yaquina Launch

Visual inspection performed on hull shell plating and stiffening.

T9074-AS-GIB-010/271 Rev. 1

Date Calib.

Additional Information

Procedure

Light Meter DLM 1000 Serial No.

Pitting under rubrail

Fracture at rudder stock hull penetration

Fracture in bottom plate

Michael Fiskum Signature

SNT-TC-1A Level II

Port Btm. Plt.

Project

UV fc

Inspector (Print Name) 3/18/2022

Description

Pitting in base material

Pitting under rubrail

Fracture at rudder stock hull penetration

Fracture in bottom plate

Fracture in bottom plate

Fracture at rudder stock hull penetration

Fracture in frame weld

Visual Acuity expires

Michael Fiskum

We hereby certify that the above information was examined in accordance with the specified requirements, and that the results indicated are the accurate interpretation of the undersigned inspector to the best of his/her knowledge, ability and integrity.

Signature

SNT-TC-1A Level II

Report No. P7555

T9074-AS-GIB-010/271 Rev. 1

10/19/21

WO# G222-9637 Dredge Yaquina Launch

Procedure

Material:

RevisionII-33-3003

Performed liquid dye penetrant testing on the items below.

13 Acceptance Criteria µW/cm2

02/26/22203199 A,B,C

Specification

Penetrant:

Stbd Btm. Plt.

Light Meter Reading

Page

Date/Time

Accept

LIQUID PENETRANT TEST REPORT

U.S. Army Corps of Engineers

RejectIndication # Location

Stbd Bow

800N/A White

Alluminum N/AThickness:

Additional Information:

Application:

Brushed

836-A1

0Port Btm. Plt.

Stbd Side Shell

Port Btm. Plt.

Client Information Only

Dwell Time:

Calib. DueSerial No.

Batch No.: 924-H6

Sherwin D40

Port Btm. Plt.

Frame M

Remover: Sherwin DR60 Batch No.: 923-H4

Developer: Sprayed

Light Meter DLM 1000 Date Calib. 08/26/21

10 Minutes

Dwell Time: 10 Minutes

Pre-Clean Procedure: Solvent spray and clean cloth wipe

Application: Batch No.:

Sherwin D100

LIQUID PENETRANT TEST REPORT

Page

U.S. Army Corps of Engineers Report No. P7555 Date/Time 10/19/21

We hereby certify that the above information was examined in accordance with the specified requirements, and that the results indicated are the accurate interpretation of the undersigned inspector to the best of his/her knowledge, ability and integrity.

Indication #1 (Visual) Indication #1 (PT)

Representative of pitting at various areas of the hull. No indication of pitting penetrating hull.

LIQUID PENETRANT TEST REPORT

Page

U.S. Army Corps of Engineers Report No. P7555 Date/Time 10/19/21

Indication #2 (Visual)

Indication of possible deviation.

We hereby certify that the above information was examined in accordance with the specified requirements, and that the results indicated are the accurate interpretation of the undersigned inspector to the best of his/her knowledge, ability and integrity.

LIQUID PENETRANT TEST REPORT

Page

U.S. Army Corps of Engineers Report No. P7555 Date/Time 10/19/21

We hereby certify that the above information was examined in accordance with the specified requirements, and that the results indicated are the accurate interpretation of the undersigned inspector to the best of his/her knowledge, ability and integrity.

Indication #3 (Visual) Indication #3 (PT)

Indication of surface roughness and .10" pit at arrow.Representative of pitting and surface roughness behind rubrail.

LIQUID PENETRANT TEST REPORT

Page

U.S. Army Corps of Engineers Report No. P7555 Date/Time 10/19/21

Indication #4 Outside (Above), Inside (Below) (Visual) Indication #4 Outside (Above). Inside (Below) (PT)

We hereby certify that the above information was examined in accordance with the specified requirements, and that the results indicated are the accurate interpretation of the undersigned inspector to the best of his/her knowledge, ability and integrity.

Indication of fracture at weld toe in rudder post doubler. Indication of fracture at weld toe in rudder post doubler.

LIQUID PENETRANT TEST REPORT

Page

U.S. Army Corps of Engineers Report No. P7555 Date/Time 10/19/21

Indication #5 (Visual) Indication #5 (PT)

Indication of melt through and possible fracture. Indication of base material fracture.

We hereby certify that the above information was examined in accordance with the specified requirements, and that the results indicated are the accurate interpretation of the undersigned inspector to the best of his/her knowledge, ability and integrity.

LIQUID PENETRANT TEST REPORT

Page

U.S. Army Corps of Engineers Report No. P7555 Date/Time 10/19/21

Indication #6 (Visual) Indication #6 (PT)

Indication of possible fracture. Indication of base material fracture.

We hereby certify that the above information was examined in accordance with the specified requirements, and that the results indicated are the accurate interpretation of the undersigned inspector to the best of his/her knowledge, ability and integrity.

LIQUID PENETRANT TEST REPORT

Page

U.S. Army Corps of Engineers Report No. P7555 Date/Time 10/19/21

Indication #7 Outside (Above), Inside (Below) (Visual) Indication #7 Outside (Above). Inside (Below) (PT)

We hereby certify that the above information was examined in accordance with the specified requirements, and that the results indicated are the accurate interpretation of the undersigned inspector to the best of his/her knowledge, ability and integrity.

Indication of fracture at weld toe in rudder post doubler. Indication of fracture at weld toe in rudder post doubler.

LIQUID PENETRANT TEST REPORT

Page

U.S. Army Corps of Engineers Report No. P7555 Date/Time 10/19/21

Indication #8 (Visual) Indication #8 (PT)

Indication of fracture in weld at Frame M. Indication of fracture in weld at Frame M.

We hereby certify that the above information was examined in accordance with the specified requirements, and that the results indicated are the accurate interpretation of the undersigned inspector to the best of his/her knowledge, ability and integrity.

US Army Corp of Eng. 10/08/2021

International Insp Job# WR-P7555

27' 5" Dredge Yaquina Launch Boat

PMI Procedure: II-54-7006 Rev.6

PMI Instrument: Thermo Scientific Niton XL2 980

Instrument S/N# 112678

Tech: D. Rosian

Reading No Time Type Duration Units Sequence Item Description Material ID Al Al Error Mn Mn Error Results

1 10/19/2021 10:16 System Check 53.91 cps Final System Check 1 of 2 Pass

2 10/19/2021 10:18 System Check 55.34 cps Final System Check 2 of 2 Pass

3 10/19/2021 10:18 General Metals 10 % Final AA 6061 Calibration Standard AA 6061 : 0.00 99.07 0.033 0.099 0.026 Pass

4 10/19/2021 10:19 General Metals 10 % Final Stbd. SSHL - Aft Section AA 5086 : 1.31 98.73 0.043 0.63 0.054 Pass

5 10/19/2021 10:20 General Metals 10 % Final Stbd. SSHL - Mid Section AA 5086 : 1.33 98.85 0.041 0.553 0.053 Pass

6 10/19/2021 10:21 General Metals 10 % Final Stbd. SSHL - Fwd. Section AA 5086 : 0.96 98.83 0.04 0.602 0.053 Pass

7 10/19/2021 10:21 General Metals 10 % Final Port SSHL - Aft Section AA 5086 : 1.06 98.79 0.043 0.607 0.055 Pass

8 10/19/2021 10:22 General Metals 10 % Final Port SSHL - Mid Section AA 5086 : 1.28 98.78 0.044 0.63 0.057 Pass

9 10/19/2021 10:22 General Metals 10 % Final Port SSHL - Fwd. Section AA 5086 : 1.28 98.83 0.041 0.601 0.054 Pass

10 10/19/2021 10:23 General Metals 10 % Final Transom Plate AA 5086 : 1.26 98.84 0.04 0.637 0.054 Pass

11 10/19/2021 10:24 General Metals 10 % Final Btm. Plate - Port Aft Section AA 5086 : 0.87 98.86 0.039 0.58 0.052 Pass

12 10/19/2021 10:24 General Metals 10 % Final Btm. Plate - Port Mid Section AA 5086 : 1.57 98.8 0.041 0.599 0.053 Pass

13 10/19/2021 10:25 General Metals 10 % Final Btm. Plate - Port Fwd Section AA 5086 : 1.54 98.74 0.045 0.677 0.058 Pass

14 10/19/2021 10:26 General Metals 10 % Final Btm. Plate - Stbd. Aft Section AA 5086 : 1.67 98.75 0.046 0.606 0.057 Pass

15 10/19/2021 10:27 General Metals 10 % Final Btm. Plate - Stbd. Mid Section AA 5086 : 0.90 98.82 0.041 0.623 0.054 Pass

16 10/19/2021 10:27 General Metals 10 % Final Btm. Plate - Stbd. Fwd Section AA 5086 : 1.65 98.76 0.043 0.636 0.055 Pass

17 10/19/2021 10:28 General Metals 10 % Final Port Push Knee AA 5086 : 0.80 99.19 0.028 0.49 0.048 Pass

18 10/19/2021 10:29 General Metals 10 % Final Stbd. Push Knee AA 5086 : 0.90 99.16 0.031 0.525 0.052 Pass

19 10/19/2021 10:30 General Metals 10 % Final Cabin - Aft Section Stbd. AA 5086 : 1.20 98.8 0.042 0.621 0.056 Pass

20 10/19/2021 10:31 General Metals 10 % Final Cabin - Aft Section Port. AA 5086 : 1.23 98.84 0.039 0.586 0.051 Pass

21 10/19/2021 10:32 General Metals 10 % Final Cabin - Fwd. Section Stbd. AA 5086 : 0.79 99 0.037 0.492 0.051 Pass

22 10/19/2021 10:32 General Metals 10 % Final Cabin - Fwd. Section Port. AA 5086 : 0.88 98.97 0.037 0.475 0.049 Pass

23 10/19/2021 10:33 General Metals 10 % Final Cabin - Port Side AA 5086 : 0.80 98.8 0.041 0.638 0.055 Pass

24 10/19/2021 10:34 General Metals 10 % Final Cabin - Stbd Side AA 5086 : 1.26 98.76 0.042 0.647 0.055 Pass

25 10/19/2021 10:35 General Metals 10 % Final Cabin - Roof AA 5086 : 1.64 98.74 0.042 0.613 0.053 Pass

26 10/19/2021 10:36 General Metals 10 % Final Frame M - Stbd Side AA 5086 : 0.79 98.8 0.044 0.586 0.056 Pass

27 10/19/2021 10:37 General Metals 10 % Final Frame L - Stbd Side AA 5086 : 0.79 98.88 0.039 0.534 0.05 Pass

28 10/19/2021 10:38 General Metals 10 % Final Stbd. Rudder Post - Top Plate AA 5086 : 1.01 99.13 0.03 0.529 0.049 Pass

29 10/19/2021 10:39 General Metals 10 % Final Aft Hook Hatch Box AA 5086 : 0.79 98.63 0.05 0.692 0.061 Pass

30 10/19/2021 10:41 General Metals 10 % Final 3" Shaft Tubing - Stbd Side AA 5086 : 0.96 98.9 0.039 0.505 0.05 Pass

27' 5" Dredge Yaquina Launch Boat

PMI Procedure: II-54-7006 Rev.6

PMI Instrument: Thermo Scientific Niton XL2 980

Instrument S/N# 112678

Tech: D. Rosian

Reading No Time Type Duration Units Sequence Item Description Material ID Al Al Error Mn Mn Error Results

31 10/19/2021 10:42 General Metals 10 % Final Stbd. Engine Bed Longitudinal AA 5086 : 1.69 99.09 0.032 0.359 0.042 Pass

32 10/19/2021 10:44 General Metals 10 % Final Fuel Tank Top Plate AA 5086 : 0.79 98.83 0.04 0.58 0.052 Pass

33 10/19/2021 10:45 General Metals 10 % Final Port Rudder Post - Top Plate AA 5086 : 0.79 99.13 0.031 0.497 0.05 Pass

34 10/19/2021 10:45 General Metals 10 % Final Frame M - Port Side AA 5086 : 0.79 98.81 0.041 0.589 0.053 Pass

35 10/19/2021 10:46 General Metals 10 % Final Frame L - Port Side AA 5086 : 0.79 98.87 0.043 0.558 0.057 Pass

37 10/19/2021 10:50 General Metals 10 % Final Deck - Aft Section AA 5086 : *2.06 98.75 0.045 0.571 0.054 Pass

38 10/19/2021 10:54 General Metals 10 % Final AA 6061 Calibration Standard AA 6061 : 0.00 99.1 0.032 0.095 0.026 Pass

AA 5086 Composition Range

Aluminum (Al): 93.0 - 96.3

Manganese (Mn): 0.20 - 0.70

Technician: Daniel C Rosian 10/19/2021

27' 5" Dredge Yaquina Launch Boat

PMI Procedure: II-54-7006 Rev.6

PMI Instrument: Thermo Scientific Niton XL2 980

Instrument S/N# 112678

Tech: D. Rosian