This document contains ultrasonic thickness measurements of the port sewage flat tank top on the USACE dredge Yaquina. Measurements were taken at 112 points on the tank top, with 18.75% wastage shown in blue and 25% wastage shown in red. Substantial wastage was found at 10 of the measured points, with percentages ranging from 24.80% to 43.47%. The average wastage across the tank top was 30%.
The related federal contract opportunity is a solicitation issued by the Department of the Army Corps of Engineers Engineering District Portland for FY24 overhaul work of the USACE dredge Yaquina. Solicitation number is W9127N23B0014. No further details are provided on products or services required, response dates, or other salient information.
View the file
Other files
Show 40 more
Latest 50 of 119 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
No Access
No Access
Manhole Manhole
CL
21" Rise
Fr. 78
Forward
USACE Dredge "YAQUINA" Ultrasonic Thickness Measurements of Port Sewage Flat Tank Top
Drawing 28
.234 .236
.262
.210
.225
.215
.315
.281
.212
.331
.277
.339.282
.280
Note: Substantial wastage [18.75%] readings are shown in (blue) and excessive wastage [25%] readings are shown in (red).
See following spreadsheet for a complete list of readings and wastage.
.280
Note: Blue percentages show Substantial wastage. Red percentages show excessive wastage.
info@certifiedndt.com
(253-952-2337
Report: 53303 Date: 3/3/2023
1 2 3 4 5 6 7 8 9 10 .375 .280 .282 .339 .212 .277 .331 .281 .262 .234 .236
%Wastage 25.33% 24.80% 9.60% 43.47% 26.13% 11.73% 25.07% 30.13% 37.60% 37.07% .375 .280 .215 .225 .315 .210 .265
%Wastage 25.33% 42.67% 40.00% 16.00% 44.00% 29.26% .263
Avg./ % Loss
Sewage Flat Tank Top
1 Port Tank Top 30% .263
Sewage Flat Tank Top
[cont.] Port Tank Top 30%
USACE Dredge "YAQUINA"
Ultrasonic Thickness Measurements of: Port Sewage Flat Tank Top [Drawing 28]
Structure Location Number Side Structural
Member Max. Allow.
Wastage Max.
Dim.
Nominal Thickness
Readings
File details come from the government source that posted it. Updated .