This document is a set of architectural and engineering plans for a Fire Alarm and Mass Notification (FA-MN) system for a Reception Complex facility. The plans depict system layouts, component locations, operational matrices, and technical specifications for a comprehensive fire detection and emergency communication infrastructure.

The system includes manual fire alarm pull stations, smoke detectors (duct-mounted and standard), heat detectors, sprinkler water flow switches, sprinkler valve tamper switches, back flow preventer tamper switches, and carbon monoxide detectors distributed throughout multiple building sections. Notification components comprise fire alarm strobes (clear lens marked "ALERT"), wall-mounted and ceiling-mounted grill speakers, weatherproof horn speakers, and emergency message display panels. The control architecture centers on a Fire Alarm and Mass Notification and Public Address (FA-MN-PA) combined master control panel with remote local operator consoles (LOC) and a fire alarm annunciator (FAA) panel. The system employs addressable initiating devices with Class "B" supervised multiplex communication, includes a radio transceiver interface to the base-wide Giant Voice mass notification system, and provides integrated telephone paging functionality through an integral interface module. Key operational requirements specify that mass notification messages take priority over fire alarm messages, which take priority over public address messages. The system must support both pre-recorded and live voice messaging, coordinate with HVAC emergency shutdown, provide synchronized strobe operation in visible areas, and maintain full compatibility with the base-wide mass notification infrastructure. Installation specifications mandate concealed conduit routing, factory-finished red conduit components, conductor integrity monitoring, and coordination with fire department for emergency message programming.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NOTE: SOME ITEMS MAY NOT BE USED

GENERAL NOTES ABBREVIATIONS

FA-MN-PA

FAA

F

S

FIRE ALARM/MASS

NOTIFICATION

SYSTEMS OPERATIONS

MATRIX

MANUAL FIRE ALARM PULL STATION

SPRINKLER WATER FLOW SWITCH

DUCT SMOKE DETECTORS

FACP SMOKE DETECTOR (ELECTRICAL ROOM)

CARBON MONOXIDE DETECTOR

BACK FLOW PREVENTER TAMPER SWITCH

SPRINKLER VALVE TAMPER SWITCH

PIV TAMPER SWITCH

FA-MN-PA CONTROL PANEL DOOR TAMPER SWITCH

TRANSCEIVER DOOR TAMPER SWITCH

KNOX BOX TAMPER SWITCH

FACP TROUBLE

IDC OPEN

IDC SHORT

IDC GROUND

AC POWER FAILURE

TEST MODE

LOW BATTERY VOLTAGE

MASS NOTIFICATION SYSTEM NOTIFICATION ACTIVATION

LIVE VOICE ANNOUNCEMENT FROM BASEWIDE SYSTEM

PRERECORDED MESSAGE # ACTIVATED

PRERECORDED ANNOUNCEMENT ACTIVATED AT LOC

LIVE VOICE ANNOUNCEMENT ACTIVATED AT LOC

FIRE ALARM NOTIFICATION MUTED BY MNS

FIRE PUMP RUNNING

FIRE PUMP POWER LOSS

FIRE PUMP PHASE REVERSAL

D

IS

PL

AY

E

VE

N

T M

ES

SA

G E

D

IS

PL

AY

C H

AN

G

E O

F

ST

AT

U

S

R

EC

O R

D E

VE

N

T

IN

T H

E H

IS

TO

R Y

LO

G

AN

N

U N

C

IA

TE

A

LA

R

M A

T

PA

N

EL

TR

AN

SM

IT

E

VE

N T

AL

AR

M

TR

AN

SM

IT

S U

PE

R

VI

SO

R Y

SI

G

N

AL

TR

AN

SM

IT

T R

O U

BL

E

SI

G

N

AL

AC

TI

VA

TE

C

LE

AR

F

A M

N S

N O

TI

FI

C

AT

IO

N

S

TR

O

BE

S

D

IS

PL

AY

T

EX

TU

R

AL

E

M

ER

G

EN

C Y

M

ES

SA

G

E D

IS

PL

AY

BR

O

AD

C

AS

T

FI

R

E

AL

AR

M

M

ES

SA

G

E

BR

O

AD

C

AS

T

R

EC

O R

D

ED

O R

L

IV

E M

AS

S

N O

TI

FI

C

AT

IO

N

M

ES

SA

G

E

M U

TE

F

IR

E

AL

AR

M M

ES

SA

G E

M U

TE

A

V

SO

U N

D R

EI

N

FO

R

C

EM

EN

T

SY

ST

EM

S

SH

U

T D

O W

N P

R O

TE

C

TE

D

A

IR

-H

AN

D

LI

N G

U N

IT

(S

N

O

TE

BY

-P

AS

S

EG

R

ES

S

LI

G

H

TI

N G

C O

N

TR

O

LS

MASS NOTIFICATION

FIRE PUMP

SUPERVISORY SIGNALS

FIRE ALARM

FIRE DETECTION AND MASS NOTIFICATION SYMBOLS

LOC

H

F NT

FA-MN-PA AND

FAA PANELS

SUPERVISORY

STATION

NOTIFICATION AUXILLIARY

FUNCTIONS

TROUBLE SIGNALS

K

AFF ABOVE FINISHED FLOOR

C CONDUIT

COR CONTRACTING OFFICER'S REPRESENTATIVE

FACP FIRE ALARM CONTROL PANEL

GFCI GOVERNMENT FURNISHED,

CONTRACTOR INSTALLED

FA-MN-PA FIRE ALARM AND MASS NOTIFICATION AND PUBLIC

ADDRESS CONTROL PANEL

FEB FIRE EXTINGUISHER BRACKET

FEC FIRE EXTINGUISHER CABINET

MFR MANUFACTURER

MH MOUNTING HEIGHT

MNS MASS NOTIFICATION SYSTEM

NEC NATIONAL ELECTRICAL CODE

NO. NUMBER

SPD SURGE PROTECTIVE DEVICE

TVSS TRANSIENT VOLTAGE SURGE SUPRESSOR

TYP TYPICAL

UL UNDERWRITERS LABORATORY

UOI UNLESS OTHERWISE INDICATED

UON UNLESS OTHERWISE NOTED

W, WP WEATHERPROOF

1. SEE FA601 FOR ADDITIONAL NOTES CONCERNING

THE FIRE ALARM & MASS NOTIFICATION SYSTEM

COMPONENTS AND OPERATIONS.

2. SPEAKER LOCATIONS AND QUANTITIES SHALL BE

ADJUSTED AS NECESSARY TO ACHIEVE THE

SPECIFIED SPEECH INTELLIGIBILITY USING THE

SPEAKERS SUBMITTED FOR APPROVAL. SIMULATION

SOFTWARE SHALL BE USED TO CALCULATE SOUND

QUALITY. VERTICAL STORAGE CAROUSELS SHALL BE

MODELLED IN THE SOFTWARE. SEE SPECIFICATION

SECTION 28 31 76 FOR ADDITIONAL REQUIREMENTS.

3. CONDUITS SHALL BE CONCEALED IN CEILINGS AND

WALLS, EXCEPT AS SHOWN OTHERWISE.

4. MOUNT OUTLET BOXES SO THAT NONE OCCUR

BACK TO BACK IN WALLS.

5. SEAL PENETRATIONS THROUGH FLOORS OR FIRE

WALLS TO MAINTAIN THE INTEGRITY OF THE FIRE

AND ACOUSTIC RATINGS OF THE WALLS AND

FLOORS.

6. RACEWAYS CROSSING STRUCTURAL EXPANSION

JOINTS OR SEISMIC JOINTS SHALL BE PROVIDED

WITH SUITABLE EXPANSION FITTINGS OR OTHER

SUITABLE MEANS TO COMPENSATE FOR THE

BUILDING EXPANSION AND CONTRACTION AND TO

PROVIDE FOR CONTINUITY OF GROUNDING.

7. FOR TYPICAL MOUNTING HEIGHTS, SEE E-001.

FIRE ALARM & MASS NOTIFICATION MATRIX NOTES

1. THE MASS NOTIFICATION SYSTEM SHALL TEMPORARILY

INTERRUPT THE FIRE ALARM AUDIBLE MESSAGE AND

VISUAL NOTIFICATION APPLIANCES DURING

SIMULTANEOUS FIRE AND MASS EVACUATION EVENTS.

ALL OTHER FEATURES OF THE FIRE ALARM SYSTEM

SHALL FUNCTION PROPERLY. DURING THE

INTERRUPTION OF THE FIRE ALARM AUDIBLE AND VISUAL

SIGNALS, A DISTINCT SUPERVISORY SIGNAL SHALL BE

ANNUNCIATED (BOTH AUDIBLY AND VISUALLY) AT THE

FACP (AND REMOTE FIRE ALARM ANNUNCIATORS) AND

SHALL BE TRANSMITTED TO THE CENTRAL FIRE ALARM

SYSTEM.

2. SEE MECHANICAL SHEETS FOR HVAC SHUT-DOWN AND

CARBON MONOXIDE CONTROL DETAILS.

FIRE ALARM MANUAL PULL STATION.

FIRE ALARM MANUAL PULL STATION ON A SEPERATE INITIATION CIRCUIT

EXCLUDED FROM TESTING WHEN THE DETECTION OR SPRINKLER SYSTEM IS

PLACED IN "TEST" MODE. (SEE NFPA 72 PARA A-23.8.5.1.2.)

FIRE ALARM AND MASS NOTIFICATION STROBE (CLEAR) MARKED "ALERT", WALL

MOUNTED. NUMBER INDICATES INTENSITY. WALL MOUNTED 7'-6" AFF OR 6"

BELOW CEILING, WHICHEVER IS LOWER. NUMBER INDICATES CANDELA

RATING. 'WP' INDICATES WEATHERPROOF.

FIRE ALARM/ MASS NOTIFICATION/ PAGING SYSTEM GRILL SPEAKER, CEILING

MOUNTED WHERE APPLICABLE. PENDANT MOUNT AT HEIGHT OF LIGHT

FIXTURES IN SPACES WITH NO CEILINGS.

FIRE ALARM/ MASS NOTIFICATION/ PAGING SYSTEM GRILL SPEAKER, WALL

MOUNTED 7'-6" AFF UON. 'WP' INDICATES WEATHERPROOF.

FIRE ALARM/ MASS NOTIFICATION/ PAGING SYSTEM HORN SPEAKER,

WEATHERPROOF, PENDANT OR WALL MOUNTED AS INDICATED .

KNOX BOX (SEE ARCHITECTURE SHEETS).

HEAT DETECTOR.

SMOKE DETECTOR.

DUCT SMOKE DETECTOR (SEE MECHANICAL SHEETS).

SPRINKLER SYSTEM FLOW SWITCH (SEE FIRE PROTECTION SHEETS).

SPRINKLER SYSTEM TAMPER SWITCH (SEE FIRE PROTECTION SHEETS).

FIRE ALARM & MASS NOTIFICATION & PUBLIC ADDRESS SYSTEM CONTROL

PANEL.

FLUSH MOUNTED FIRE ALARM ANNUNCIATOR PANEL.

FLUSH MOUNTED MASS NOTIFICATION SYSTEM "LOCAL OPERATOR CONSOLE".

FIRE ALARM AND MASS NOTIFICATION TEXTUAL EMERGENCY MESSAGE

DISPLAY, WALL MOUNTED

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXDGV\Documents\FY18JA76149_RECEPTION COMPLEX_MEP_R21_K6ENXDGV.rvt

5/3/2024 1:51:31 PM

JU

N

E

W

2H P1

9R

M . B

R

EN

N

AN

P.

S

U

LL

IV

AN

2-

-0

FA001

FI

R

E

AL

AR

M

L

EG

EN

D

A N

D O

PE

R

AT

IO

N S

M

AT

R

IX

H

AG

O

O D

A

VE

N U

E C

H

AR

LE

ST

O N

D

IS

TR

IC

T C

H

AR

LE

ST

O N

, S O

U

TH

C

AR

O

LI

N A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

SA

VA

N

N

AH

D

IS

TR

IC

T

W

. O G

LE

TH

O R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T

JA

C

KS

O N

, S O

U

TH

C

AR

O

LI

N A

R

EC

EP

TI

O N

C O

M

PL

EX

P

H

AS

E

FY

8, P

N

VO

LU

M E

-C

LO

TH

IN

G

IN

IT

IA

L

IS

SU

E

PO

IN

T

(C

IIP

T.

F

U N

K

ISSUE FOR CONSTRUCTION

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

A U

G

0 1

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

B C

D -0

AP

R

2 3

S

S

S

S

S S

S

S

S

S

S

S

S

S S S S S S S S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S S S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S S

S

S

S S S S

S S S

S

S

S

S

S

S

S

S

S S

S

S S S S S

S

S

S

S

S

S

S

S

SSS

S

S

S

S

S

S

S

S

S S

S S

S

S SS

S S S

S S S

S S S

S S S

S

FP

C

P

JP

C P

S

S

S

S

S

S

S

S

S S S S

S

S

S

S

S

S

S

S

S

S

S

S

S S SS S S S

S S

S S S

S S

S S S

S S

S S S

S S S

S S S

S

S

SS

SSS

SSS

S

S

S

S

S S

S

S

S

S

S

S

S S

S S S

S S S

S

S

S S S S

S S S S

S S S S

S S

S S

S

S

SSS

S S

S S

S S

S S

S

S S

SS

S

S

SS

S

SS

S

SS

S

S

S S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S S S

S S S

S S S

S S S

S S S

S S S

S S

THIS COMPOSITE PLAN PRESENTS A OVERALL

LOCATION VIEW OF ALL FLOOR PLAN PARTS. THE

ACTUAL SPECIFIC FLOOR PLANS SHEETS ARE

INDICATED BY THE KEY PLAN BELOW.

COMPOSITE PLAN:

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXDGV\Documents\FY18JA76149_RECEPTION COMPLEX_MEP_R21_K6ENXDGV.rvt

5/3/2024 1:51:41 PM

JU

N

E

W

2H P1

9R

M . B

R

EN

N

AN

P.

S

U

LL

IV

AN

2-

-0

FA100

FI

R

E

AL

AR

M

A N

D M

N S

PL

AN

C

O M

PO

SI

TE

H

AG

O

O D

A

VE

N U

E C

H

AR

LE

ST

O N

D

IS

TR

IC

T C

H

AR

LE

ST

O N

, S O

U

TH

C

AR

O

LI

N A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

SA

VA

N

N

AH

D

IS

TR

IC

T

W

. O G

LE

TH

O R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T

JA

C

KS

O N

, S O

U

TH

C

AR

O

LI

N A

R

EC

EP

TI

O N

C O

M

PL

EX

P

H

AS

E

FY

8, P

N

VO

LU

M E

-C

LO

TH

IN

G

IN

IT

IA

L

IS

SU

E

PO

IN

T

(C

IIP

T.

F

U N

K

ISSUE FOR CONSTRUCTION

FIRE ALARM AND MNS PLAN - COMPOSITE1

TRUE NORTHPLAN NORTH

KEY PLAN

PART C PART D

PART

A

PART B

PART E

SCALE: 3/64"=1'-0"

1632 32

FA101 FA102

FA103 FA104

FA105

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

S S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

SS

S S S S

S S

S S

S

S

S S ELECT 2

TER 2

RFID

CORRIDOR

CORRIDOR

OFFICE

PH 1 ISSUE

WAREHOUSE

CORRIDOR

F

F

F

F

WP

WP

WP

110 110 110

110110110

WAREHOUSE

FIRE PUMP

SECURE STORAGE

15 15 15

CIIP DX

WAREHOUSE

WAREHOUSE

F

15 15

WP

WAREHOUSE

LOC

WP

SPRINKLER SYSTEM WATER FLOW SWITCHES

AND VALVE TAMPER SWITCHES. SEE SHEETS

FX102, FX501, FX502 FOR SPECIFIC

QUANTITIES AND LOCATIONS.

FIRE

PUMP

H

PENDANT

MOUNTED

MH=25'-0"

AFF

H

PENDANT

MOUNTED

MH=25'-0"

AFF

H

H

PENDANT

MOUNTED

MH=25'-0"

AFF

PENDANT

MOUNTED

MH=25'-0"

AFF

15 15

EXIT CORR.

167A

1. SEE SHEET FA001 FOR LEGEND, NOTES, AND OPERATION MATRIX.

2. SEE SHEET FA501 FOR FIRE ALARM AND MNS DIAGRAMS.

3. SEE E001 FOR MOUNTING HEIGHT DETAIL AND ADDITIONAL NOTES.

4. CORDINATE LOCATION OF TEXTURAL EMERGENCY MESSAGE DISPLAY SIGNS

WITH EXIT SIGNS. WHERE MOUNTED SIDE-BY-SIDE (PREFERRED) , ALIGN TOPS AND

SPACE SIGNS NO LESS THAN 6-INCHES FROM EDGE TO EDGE. WHERE MOUNTED

ONE ABOVE ANOTHER, ALIGN CENTERLINES OF SIGNS WITH CENTERLINE OF DOOR

AND MOUNT TEXTURAL EMERGENCY MESSAGE DISPLAY SIGNS NO LESS THAN 6-

INCHES ABOVE EXIT SIGNS.

FIRE ALARM NOTES:

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXDGV\Documents\FY18JA76149_RECEPTION COMPLEX_MEP_R21_K6ENXDGV.rvt

5/3/2024 1:51:48 PM

JU

N

E

W

2H P1

9R

M . B

R

EN

N

AN

P.

S

U

LL

IV

AN

2-

-0

FA101

FI

R

E

AL

AR

M

A N

D M

N S

PL

AN

PA

R T

A

H

AG

O

O D

A

VE

N U

E C

H

AR

LE

ST

O N

D

IS

TR

IC

T C

H

AR

LE

ST

O N

, S O

U

TH

C

AR

O

LI

N A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

SA

VA

N

N

AH

D

IS

TR

IC

T

W

. O G

LE

TH

O R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T

JA

C

KS

O N

, S O

U

TH

C

AR

O

LI

N A

R

EC

EP

TI

O N

C O

M

PL

EX

P

H

AS

E

FY

8, P

N

VO

LU

M E

-C

LO

TH

IN

G

IN

IT

IA

L

IS

SU

E

PO

IN

T

(C

IIP

T.

F

U N

K

ISSUE FOR CONSTRUCTION

TRUE NORTHPLAN NORTH

KEY PLAN

PART C PART D

PART

A

PART B

PART E

SCALE: 3/32"=1'-0"

816 16FIRE ALARM AND MNS PLAN - PART A1

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

B C

D -0

AP

R

2 3

R

EV

IS

ED

IN

A

C C

O R

D

AN

C E

W

IT

H B

C D

-0

AU

G

2 3

S S

S

S

S

S

S S S S S

S

S

S

S

S

S

S

S

S

S SS

S S

S S S

S

S

S

S

S S

SS

S

S

SS

S

SS

S

S S S

S S S

S S S

TOILET

JAN. CL

MECH 2

RFID

CORRIDOR

CORRIDOR

CORRIDOR

F

F

F

LOC

WP

WP

110 110 110

110110

WAREHOUSE OFFICES

BREAKROOM

TER.

MECH.

ELECT.

STORAGE

OFFICE

F F

TAILORING

EXIT CORR.

WAREHOUSE

WAREHOUSE

F

WAREHOUSE

WAREHOUSE

H

H

H

PENDANT

MOUNTED

MH=25'-0"

AFF

PENDANT

MOUNTED

MH=25'-0"

AFF

PENDANT

MOUNTED

MH=25'-0"

AFF

PH 2 ISSUE

TAILORING

EXIT CORR.

1. SEE SHEET FA001 FOR LEGEND, NOTES, AND OPERATION MATRIX.

2. SEE SHEET FA501 FOR FIRE ALARM AND MNS DIAGRAMS.

3. SEE E001 FOR MOUNTING HEIGHT DETAIL AND ADDITIONAL NOTES.

4. CORDINATE LOCATION OF TEXTURAL EMERGENCY MESSAGE DISPLAY SIGNS

WITH EXIT SIGNS. WHERE MOUNTED SIDE-BY-SIDE (PREFERRED) , ALIGN TOPS AND

SPACE SIGNS NO LESS THAN 6-INCHES FROM EDGE TO EDGE. WHERE MOUNTED

ONE ABOVE ANOTHER, ALIGN CENTERLINES OF SIGNS WITH CENTERLINE OF DOOR

AND MOUNT TEXTURAL EMERGENCY MESSAGE DISPLAY SIGNS NO LESS THAN 6-

INCHES ABOVE EXIT SIGNS.

FIRE ALARM NOTES:

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXDGV\Documents\FY18JA76149_RECEPTION COMPLEX_MEP_R21_K6ENXDGV.rvt

5/3/2024 1:51:53 PM

JU

N

E

W

2H P1

9R

M . B

R

EN

N

AN

P.

S

U

LL

IV

AN

2-

-0

FA102

FI

R

E

AL

AR

M

A N

D M

N S

PL

AN

PA

R T

B

H

AG

O

O D

A

VE

N U

E C

H

AR

LE

ST

O N

D

IS

TR

IC

T C

H

AR

LE

ST

O N

, S O

U

TH

C

AR

O

LI

N A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

SA

VA

N

N

AH

D

IS

TR

IC

T

W

. O G

LE

TH

O R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T

JA

C

KS

O N

, S O

U

TH

C

AR

O

LI

N A

R

EC

EP

TI

O N

C O

M

PL

EX

P

H

AS

E

FY

8, P

N

VO

LU

M E

-C

LO

TH

IN

G

IN

IT

IA

L

IS

SU

E

PO

IN

T

(C

IIP

T.

F

U N

K

ISSUE FOR CONSTRUCTION

TRUE NORTHPLAN NORTH

KEY PLAN

PART C PART D

PART

A

PART B

PART E

SCALE: 3/32"=1'-0"

816 16FIRE ALARM AND MNS PLAN - PART B1

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

B C

D -0

AP

R

2 3

R

EV

IS

ED

IN

A

C C

O R

D

AN

C E

W

IT

H B

C D

-0

AU

G

2 3

S

S

S

S

S S S

S S S S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S S

S S S S

S S

S S S

S S

S S S

S

S S

S S

S S

S

S

S

S

S

S S

S S S

S S S

S

S

S S S S

S S S S

S S

S S

S S

S S

S

RFID

CORRIDOR

OPEN OFFICE

CONF

CORRIDOR

CORRIDOR

CONT

SCAN 1

SCAN 2

CORRIDOR

CORRIDOR

UNISEX TOILET

MOTHERS RM

JAN

CLASSROOM

CIIP DX

CORRIDOR

CORRIDOR

PH 1 ISSUE

NIGHT ISSUE

F

F

F

F

F F

FA-MN-PA

WP

WP WP

BREAK ROOM

CIF RETAINED ISSUE

WOMEN

MEN

OFFICE

D.

BRIEFING RM

VEST B

CIF RETAINED ISSUE

MECH 1

TER 1

ELECT 1

VEST A

LO

C

LO

C

NIGHT ISSUE

SPRINKLER SYSTEM WATER FLOW

SWITCHES AND VALVE TAMPER SWITCHES.

SEE SHEETS FX103, FX501, FX502 FOR

SPECIFIC QUANTITIES AND LOCATIONS.

WP

WP

F

1. SEE SHEET FA001 FOR LEGEND, NOTES, AND OPERATION MATRIX.

2. SEE SHEET FA501 FOR FIRE ALARM AND MNS DIAGRAMS.

3. SEE E001 FOR MOUNTING HEIGHT DETAIL AND ADDITIONAL NOTES.

4. CORDINATE LOCATION OF TEXTURAL EMERGENCY MESSAGE DISPLAY SIGNS

WITH EXIT SIGNS. WHERE MOUNTED SIDE-BY-SIDE (PREFERRED) , ALIGN TOPS AND

SPACE SIGNS NO LESS THAN 6-INCHES FROM EDGE TO EDGE. WHERE MOUNTED

ONE ABOVE ANOTHER, ALIGN CENTERLINES OF SIGNS WITH CENTERLINE OF DOOR

AND MOUNT TEXTURAL EMERGENCY MESSAGE DISPLAY SIGNS NO LESS THAN 6-

INCHES ABOVE EXIT SIGNS.

FIRE ALARM NOTES:

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXDGV\Documents\FY18JA76149_RECEPTION COMPLEX_MEP_R21_K6ENXDGV.rvt

5/3/2024 1:51:59 PM

JU

N

E

W

2H P1

9R

M . B

R

EN

N

AN

P.

S

U

LL

IV

AN

2-

-0

FA103

FI

R

E

AL

AR

M

A N

D M

N S

PL

AN

PA

R T

C

H

AG

O

O D

A

VE

N U

E C

H

AR

LE

ST

O N

D

IS

TR

IC

T C

H

AR

LE

ST

O N

, S O

U

TH

C

AR

O

LI

N A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

SA

VA

N

N

AH

D

IS

TR

IC

T

W

. O G

LE

TH

O R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T

JA

C

KS

O N

, S O

U

TH

C

AR

O

LI

N A

R

EC

EP

TI

O N

C O

M

PL

EX

P

H

AS

E

FY

8, P

N

VO

LU

M E

-C

LO

TH

IN

G

IN

IT

IA

L

IS

SU

E

PO

IN

T

(C

IIP

T.

F

U N

K

ISSUE FOR CONSTRUCTION

TRUE NORTHPLAN NORTH

KEY PLAN

PART C PART D

PART

A

PART B

PART E

SCALE: 3/32"=1'-0"

816 16FIRE ALARM AND MNS PLAN - PART C1

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

B C

D -0

AP

R

2 3

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S S S

S S S

S

S

S

S

S

S

S

S

S S

S

S

S

S

S

S

SSS

S

S

S

S

S

S S

S S

S S

S S

S

S

S

S

S

S

S

S

S S S

S S

S S

S S

S S

S

SS

SSS

SSS

S

S

S

S

S S

S

SSS

SS

S

SS

S

S S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S S S

S S S

S S S

RFID

CORRIDOR

O

PE

N O

FF

IC

E

OFF

OFF

OFF

OFF

CORRIDOR

DRESSING (MEN)

DRESSING (WOMEN)

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

OFF

MECH 3

CADRE

MOTHER RM

F F

F

F

F

F

F

FA

A

WP

WP

CONF

D.

WOMEN

MEN

JAN

BREAK

VEST D

AFEES

STEAM PRESS

TER 3

ELECT 3

STOR

TAILORING

BRIEFING RM

VEST C

WP

LO

C

LO

C

K

PH 2 ISSUE

BRIEFING RM

TAILORING

1. SEE SHEET FA001 FOR LEGEND, NOTES, AND OPERATION MATRIX.

2. SEE SHEET FA501 FOR FIRE ALARM AND MNS DIAGRAMS.

3. SEE E001 FOR MOUNTING HEIGHT DETAIL AND ADDITIONAL NOTES.

4. CORDINATE LOCATION OF TEXTURAL EMERGENCY MESSAGE DISPLAY SIGNS

WITH EXIT SIGNS. WHERE MOUNTED SIDE-BY-SIDE (PREFERRED) , ALIGN TOPS AND

SPACE SIGNS NO LESS THAN 6-INCHES FROM EDGE TO EDGE. WHERE MOUNTED

ONE ABOVE ANOTHER, ALIGN CENTERLINES OF SIGNS WITH CENTERLINE OF DOOR

AND MOUNT TEXTURAL EMERGENCY MESSAGE DISPLAY SIGNS NO LESS THAN 6-

INCHES ABOVE EXIT SIGNS.

FIRE ALARM NOTES:

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXDGV\Documents\FY18JA76149_RECEPTION COMPLEX_MEP_R21_K6ENXDGV.rvt

5/3/2024 1:52:04 PM

JU

N

E

W

2H P1

9R

M . B

R

EN

N

AN

P.

S

U

LL

IV

AN

2-

-0

FA104

FI

R

E

AL

AR

M

A N

D M

N S

PL

AN

PA

R T

D

H

AG

O

O D

A

VE

N U

E C

H

AR

LE

ST

O N

D

IS

TR

IC

T C

H

AR

LE

ST

O N

, S O

U

TH

C

AR

O

LI

N A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

SA

VA

N

N

AH

D

IS

TR

IC

T

W

. O G

LE

TH

O R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T

JA

C

KS

O N

, S O

U

TH

C

AR

O

LI

N A

R

EC

EP

TI

O N

C O

M

PL

EX

P

H

AS

E

FY

8, P

N

VO

LU

M E

-C

LO

TH

IN

G

IN

IT

IA

L

IS

SU

E

PO

IN

T

(C

IIP

T.

F

U N

K

ISSUE FOR CONSTRUCTION

TRUE NORTHPLAN NORTH

KEY PLAN

PART C PART D

PART

A

PART B

PART E

SCALE: 3/32"=1'-0"

816 16FIRE ALARM AND MNS PLAN - PART D1

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

B C

D -0

AP

R

2 3

JAN

119 WP

WOMEN

WOMEN

JAN

BREAK

BRIEFING RM

BRIEFING RM

VEST B

VEST C

103WP

WP

MH=16'

H H H H

WP

MH=16'

WP

MH=16'

WP

MH=16'

K

1. SEE SHEET FA001 FOR LEGEND, NOTES, AND OPERATION MATRIX.

2. SEE SHEET FA501 FOR FIRE ALARM AND MNS DIAGRAMS.

3. SEE E001 FOR MOUNTING HEIGHT DETAIL AND ADDITIONAL NOTES.

4. CORDINATE LOCATION OF TEXTURAL EMERGENCY MESSAGE DISPLAY SIGNS

WITH EXIT SIGNS. WHERE MOUNTED SIDE-BY-SIDE (PREFERRED) , ALIGN TOPS AND

SPACE SIGNS NO LESS THAN 6-INCHES FROM EDGE TO EDGE. WHERE MOUNTED

ONE ABOVE ANOTHER, ALIGN CENTERLINES OF SIGNS WITH CENTERLINE OF DOOR

AND MOUNT TEXTURAL EMERGENCY MESSAGE DISPLAY SIGNS NO LESS THAN 6-

INCHES ABOVE EXIT SIGNS.

FIRE ALARM NOTES:

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXDGV\Documents\FY18JA76149_RECEPTION COMPLEX_MEP_R21_K6ENXDGV.rvt

5/3/2024 1:52:06 PM

JU

N

E

W

2H P1

9R

M . B

R

EN

N

AN

P.

S

U

LL

IV

AN

2-

-0

FA105

FI

R

E

AL

AR

M

A N

D M

N S

PL

AN

PA

R T

E

H

AG

O

O D

A

VE

N U

E C

H

AR

LE

ST

O N

D

IS

TR

IC

T C

H

AR

LE

ST

O N

, S O

U

TH

C

AR

O

LI

N A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

SA

VA

N

N

AH

D

IS

TR

IC

T

W

. O G

LE

TH

O R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T

JA

C

KS

O N

, S O

U

TH

C

AR

O

LI

N A

R

EC

EP

TI

O N

C O

M

PL

EX

P

H

AS

E

FY

8, P

N

VO

LU

M E

-C

LO

TH

IN

G

IN

IT

IA

L

IS

SU

E

PO

IN

T

(C

IIP

T.

F

U N

K

ISSUE FOR CONSTRUCTION

TRUE NORTHPLAN NORTH

KEY PLAN

PART C PART D

PART

A

PART B

PART E

SCALE: 3/32"=1'-0"

816 16FIRE ALARM AND MNS PLAN - PART E1

M

AR

K D

ES

C

R

IP

TI

O

N D

ROOF

LIGHTINING ARRESTER

RAIN PROOF

ENCLOSURE

COAXIAL CABLE PER

MANUFACTURERS

RECOMMENDATIONS

IN 3/4" " CONDUIT

TO FIRE ALARM

TRANSMITTER.

DRIP

PROOF

SERVICE

LOOP

ANTENNA OMNIDIRECTIONAL

MAST SIZE AS REQUIRED

FOR ANTENNA TO BE 6" MIN.

ABOVE ROOF/PARAPET

WALL

MOUNTED

GROUND CLAMP

RG6 COAXIAL CABLE

STANDOFF SUPPORT

CONTRACTOR TO

PROVIDE SILICONE

CAULKING AT THE

CONDUIT PENETRATION

RG6 COAXIAL CABLE

BUILDING WALL

WEATHER-

HEAD

#6 AWG GROUND WIRE.

SUPPORT THE WIRE

EVERY 4' TO 5'.

#6 AWG TO

BUILDING GROUND.

NOTE:

CONTRACTOR SHALL COORDINATE LOCATION

OF ANTENNA WITH FIRE DEPT THROUGH COR

2 3 4 5 6 7 8 and speak into microphone.

OPERATING INSTRUCTIONS:

Press microphone button

HVAC EMERGENCY SHUT OFF

MASS NOTIFICATION SYSTEM

MASS NOTIFICATION

SYSTEM

AND

HVAC EMERGENCY

SHUTOFF

***WARNING***

FOR EMERGENCY USE ONLY

ACTIVATION WILL RESULT IN

FIRST RESPONDER NOTIFICATION

GENERAL NOTES:

PANEL WITH DOOR CLOSED

DOOR SHALL BE HINGED AND

MECHANICALLY

OR MAGNETICALLY HELD CLOSED

BUTTON (TYPICAL) SHALL BE

1/2 " MIN IN DIAMETER AND

SHALL BE PUSH ON - PUSH

OFF TYPE.

MICROPHONE CABLE

SHALL BE COIL

TYPE.

PANEL WITH DOOR OPENED

MUSHROOM TYPE

PUSH BUTTON

SWITCH (RED)

PULL HANDLE

HINGES

1. SEE MECHANICAL DRAWINGS FOR CONNECTION OF "HVAC

EMERGENCY SHUTOFF" SWITCH AND ADDITIONAL

REQUIREMENTS.

2. PANEL SHALL BE SEMI FLUSH TYPE MOUNTING.

3. MOUNT LOC PANEL AT 44" AFF (MEASURED TO CONTROL

BUTTONS).

4. PANEL SHALL BE PAINTED WHITE WITH RED LETTERING.

DOOR SHALL HAVE A TAMPER WIRE, TAMPER ALARM OR

EQUIVALENT PROTECTION.

5. MOUNT A LAMINATED DIRECTORY OF BUTTON FUNCTIONS

TO THE INSIDE OF THE DOOR. WHERE THERE ARE NO

MESSAGES ASSIGNED TO THE BUTTON, " NOT USED" SHALL BE

STATED FOR THAT BUTTON FUNCTION.

6. LABEL LOC DOOR AS INDICATED.

7. MASS NOTIFICATION BUTTONS AND THE HVAC SHUT-OFF

BUTTON COLORS SHALL BE DISTINCT FROM BACKGROUND TO

RENDER THEM READILY VISIBLE. THE MASS NOTIFICATION

BUTTON COLORS SHALL BE DIFFERENT FROM THE HVAC SHUT-

OFF BUTTON COLORS.

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXDGV\Documents\FY18JA76149_RECEPTION COMPLEX_MEP_R21_K6ENXDGV.rvt

5/3/2024 1:52:08 PM

JU

N

E

W

2H P1

9R

M . B

R

EN

N

AN

P.

S

U

LL

IV

AN FY

PN

7H Q

_F A5

.D

G N

2-

-0

FA501

FI

R

E

AL

AR

M

M

AS

S

N O

TI

FI

C

AT

IO

N

D

ET

AI

LS

H

AG

O

O D

A

VE

N U

E C

H

AR

LE

ST

O N

D

IS

TR

IC

T C

H

AR

LE

ST

O N

, S O

U

TH

C

AR

O

LI

N A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

SA

VA

N

N

AH

D

IS

TR

IC

T

W

. O G

LE

TH

O R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T

JA

C

KS

O N

, S O

U

TH

C

AR

O

LI

N A

R

EC

EP

TI

O N

C O

M

PL

EX

P

H

AS

E

FY

8, P

N

VO

LU

M E

-C

LO

TH

IN

G

IN

IT

IA

L

IS

SU

E

PO

IN

T

(C

IIP

T.

F

U N

K

ISSUE FOR CONSTRUCTION

FIRE ALARM/MASS NOTIFICATION ANTENNA1

LOCAL OPERATOR CONSOLE2

M

AR

K D

ES

C

R

IP

TI

O

N D

HVAC SHUTOFF

SIGNAL

FIRE ALARM

AND MASS

NOTIFICATION AND

PUBLIC ADDRESS

(PAGING)

SYSTEM

CONTROL PANEL

(FA-MN-PA)

(NOTES 4, 5, 9)

F

SPD

REMOTE LOCAL

OPERATOR CONSOLES

(LOC) (TYPICAL)

(NOTE 7)

MNS LOC

FIRE ALARM ANNUACTOR

(FAA) PANEL (NOTE 7)

NOTE 6

CKT P1A-1

PIV BFP

EMERGENCY LIGHTING

CONTROL BY-PASS SIGNAL

NOTE 20

CKT P1A-3

BATTERY

BACK-UP

A LA

SPD

NOTES 2,6

TRANSMITTER

TO MAIN

TELECOMMUNICATIONS ROOM

FOR TELEPHONE PAGING

ACTIVATION (NOTE 19)

BATTERY

BACK-UP

INTEGRAL

TELEPHONE

PAGING

INTERFACE

MODULE

NOTE 19

DUCT MOUNTED

SMOKE DETECTORS

NOTES 1, 10

SPRINKLER WATERFLOW

AND TAMPER SWITCHES

NOTES 1, 11

BACK FLOW PREVENTOR AND

PIV TAMPER SWITCHES

NOTES 1, 12

FIRE ALARM INITIATION

DEVICES

NOTES 1, 7

co CARBON MONIXIDE INITIATION

DEVICES

NOTES 1, 3

co co

FA/MNS NOTIFICATION DEVICES

VOICE EVACUATION AND ALARM

NOTES 1, 7, 8, 17, 18

S H

SPRINKLER BELL

MANUAL STATION AT CONTROL

PANEL (DEDICATED CIRCUIT)

NOTE 13

F

FIRE ALARM AND MASS NOTIFICATION

STROBES, CLEAR LENS MARKED 'ALERT'

NOTES 1, 7, 14, 15, 17

NOTE 16

KNOX BOX KNOX BOX

NOTE 21

NT

FA/MNS NOTIFICATION DEVICES

EMERGENCY MESSAGE DISPLAY

NOTES 1, 7, 16

FIRE PUMP CONTROL

PANEL

SOUND REINFORCEMENT SYSTEM

SILENCE SIGNAL (SEE EY SHEETS)

NOTE 22

G1. THE FIRE ALARM AND MASS NOTIFICATION SYSTEM SHALL BE A COMPLETELY SUPERVISED CLASS “B” SYSTEM EMPLOYING ADDRESSABLE INITIATING DEVICES AND MULTIPLEX COMMUNICATION TECHNIQUES. EACH DETECTION, MONITOR AND CONTROL DEVICE SHALL BE INDIVIDUALLY ADDRESSABLE.

DEVICES WHICH ARE NOT INHERENTLY ADDRESSABLE (I.E. TAMPER SWITCHES, FLOW SWITCHES, FIRE PUMP, DOOR HOLDERS, ETC.) SHALL BE EQUIPPED

WITH ADDRESSABLE MONITOR AND CONTROL MODULES.

G2. THE FIRE ALARM AND MASS NOTIFICATION SYSTEM AUDITORY NOTIFICATION SHALL CONSIST OF A SUPERVISED AUDIO DISTRIBUTION NETWORK TO INCLUDE AMPLIFIERS, AUDIO BOOSTERS, AMPLIFIER SPLITTERS, MESSAGE KITS, OUTPUT CHANNEL KITS, MICROPHONES, BATTERIES, BATTERY CHARGERS, SPEAKERS, CABLING, AND ANY ANCILLARY COMPONENTS REQUIRED TO MEET THE REQUIRED SYSTEM CONFIGURATION AND OPERATION.

G3. THE CONTRACTOR SHALL INSTALL CONDUIT AND WIRING IN ACCORDANCE WITH FIRE ALARM AND MASS NOTIFICATION SYSTEM MANUFACTURER'S SHOP DRAWINGS AND REQUIREMENTS AND NFPA STANDARDS. CONDUCTOR INTEGRITY MONITORING IS REQUIRED. CONDUIT, COUPLINGS, JUNCTION BOXES, PULL BOXES AND COVERS SHALL BE FACTORY FINISHED RED.

G4. COORDINATE WITH THE FIRE DEPARTMENT FOR THE FIRE ALARM MESSAGES TO BE BROADCAST IN AN EVENT OF AN EMERGENCY.

G5. THE FIRE ALARM AND MASS NOTIFICATION SYSTEM SHALL GIVE MASS NOTIFICATION MESSAGES PRIORITY OVER FIRE ALARM MESSAGES. THE MASS NOTIFICATION SYSTEM SHALL SILENCE THE FIRE ALARM SIGNALS AND MESSAGES WHILE MASS NOTIFICATION MESSAGES ARE BEING BROADCAST.

G6. THE FIRE ALARM AND MASS NOTIFICATION SYSTEM SHALL GIVE MASS NOTIFICATION MESSAGES AND FIRE ALARM MESSAGES PRIORITY OVER PUBLIC ADDRESS (PAGING) MESSAGES. THE MASS NOTIFICATION SYSTEM SHALL SILENCE THE PUBLIC ADDRESS MESSAGES WHILE FIRE ALARM OR MASS

NOTIFICATION MESSAGES ARE BEING BROADCAST.

G7. THE FIRE ALARM AND MASS NOTIFICATION SYSTEM SHALL SILENCE ALL LOCAL AUDIO/VISUAL SOUND SYSTEMS IN THE BUILDING WHEN BROADCASTING

ANY FIRE ALARM OR MASS NOTIFICATION ALERT MESSAGES.

G8. THE MNS SHALL BE FULLY COMPATIBLE WITH THE BASE WIDE MNS. THE MNS SHALL BE CAPABLE OF ACCEPTING PRE-RECORDED AND LIVE MESSAGES FROM A REMOTE SITE BY WAY OF DRY CONTACTS AND 600 AUDIO INPUTS. THE MANUFACTURER SHALL PROVIDE AND INSTALL THE RADIO RECEIVER INTERFACE TO THE BASE WIDE WHELEN GIANT VOICE MNS. COORDINATE WITH THE MANUFACTURER TO DETERMINE THE INTERFACE REQUIREMENTS

BETWEEN THE BUILDING MNS SYSTEM AND THE BASE WIDE MNS.

G9. FIRE ALARM AND MASS NOTIFICATION MESSAGES SHALL BE PROGRAMMED PER SPECIFICATIONS.

1. THE MAXIMUM NUMBER OF INITIATION AND NOTIFICATION APPLIANCES PER CIRCUIT SHALL BE IN ACCORDANCE

WITH THE FIRE ALARM AND MASS NOTIFICATION SYSTEM CONTROL PANEL’S LIMITATIONS.

2. PROVIDE RADIO TRANSCEIVER FOR FIRE ALARM AND MASS NOTIFICATION DATA COMMUNICATION WITH THE FT.

JACKSON CENTRAL OFFICE. THE FIRE ALARM TRANSMITTER SHALL BE MONACO BT-XM RADIO TRANSMITTER OR APPROVED EQUAL AND SHALL BE 100% FULLY COMPATIBLE WITH EXISTING FT. JACKSON MONACO D21 FIRE MAMANGEMENT SYSTEM LOCATED IN BLDG 15301 - LAW ENFORCEMENT CENTER. PROVIDE LIGHTNING ARRESTER

AND ANTENNA AS RECOMMENDED BY THE MANUFACTURER.

3. CONNECT AND INTEGRATE CARBON MONOXIDE (CO) SENSORS TO FA/MNS PANEL. SENSOR ACTIVATION SHALL INITIATE CO MESSAGE PROGRAMMED INTO PANEL OVER NOTIFICATION DEVICES AS SPECIFIED. SEE THE MECHANICAL PLANS, CONTROL DIAGRAMS AND SPECIFICATIONS FOR THE EXACT NUMBER AND LOCATION OF CARBON MONOXIDE

(CO) SENSORS.

4. FIRE ALARM AND MASS NOTIFICATION SYSTEM AND PUBLIC ADDRESS (FA-MN-PA) CONTROL PANEL SHALL BE A COMBINED MASTER CONTROL PANEL HAVING THE INTEGRATED FEATURES OF A FIRE ALARM CONTROL PANEL, A MASS NOTIFICATION AUTONOMOUS CONTROL UNIT, AND A PUBLIC ADDRESS (PAGING) SYSTEM. THE CONTROL PANEL SHALL MEET THE FUNCTIONAL REQUIREMENTS INDICATED ON THE DRAWINGS AND SPECIFIED IN THE

SPECIFICATIONS.

5. PROVIDE ALL NECESSARY EQUIPMENT, COMPUTER APPLICATIONS OR PROGRAMS INCLUDING PROGRAMMING

SERVICES NEEDED TO PROGRAM AND CONFIGURE ALL PANELS AND EQUIPMENT.

6. PROVIDE A CABINET MOUNTED METAL OXIDE VARISTOR (MOV) BASED SURGE PROTECTION DEVICE (SPD) AT EACH POWER INPUT AS SHOWN. THE DEVICE SHALL SUPPLEMENT THE SPD INTEGRAL TO THE EACH PANEL. THE DEVICE SHALL BE UL 1449 LISTED (3RD EDITION) AND SHALL SATISFY THE REQUIREMENTS OF IEEE C62.41.

7. SEE THE FIRE ALARM AND MASS NOTIFICATION SYSTEM FLOOR PLANS AND SPECIFICATIONS FOR THE QUANTITY AND LOCATION OF INITIATING DEVICES, NOTIFICATION APPLIANCES, REMOTE ANNUNCIATOR AND REMOTE LOCAL

OPERATING CONSOLES.

8. LOCATIONS OF MASS NOTIFICATION SPEAKERS SHOWN ON THE DRAWINGS ARE APPROXIMATE AND QUANTITIES ARE MINIMUM. ACTUAL LOCATIONS AND QUANTITIES SHALL BE DETERMINED BY THE FIRE ALARM AND MASS NOTIFICATION SYSTEM MANUFACTURER FOR COMPLETE ROOM/BUILDING COVERAGE. FIELD TESTING AND ADJUSTMENTS OF THE SPEAKER SYSTEM SHALL BE PROVIDED IN ACCORDANCE WITH SPECIFICATION SECTION 28 31 76.

9. THE MASS NOTIFICATION SYSTEM SHALL SUPPORT BOTH MICROPHONE INPUT AND THE DELIVERY OF LOCALLY

PRE-RECORDED MESSAGES.

10. SEE THE MECHANICAL PLANS, CONTROL DIAGRAMS AND SPECIFICATIONS FOR THE EXACT NUMBER AND

LOCATION OF DUCT MOUNTED SMOKE DETECTORS.

11. SEE THE FIRE PROTECTION PLANS AND SPECIFICATIONS FOR THE EXACT NUMBER AND LOCATIONS OF SPRINKLER

FLOW AND TAMPER SWITCHES.

12. POST INDICATOR VALVE (PIV) AND BACKFLOW PREVENTER (BFP) TAMPER SWITCHES SHALL BE WITHIN 100 FEET

OF THE BUILDING. COORDINATE WITH INSTALLATION WATER UTILITY FOR EXACT LOCATION.

13. A MANUAL PULL STATION SHALL BE LOCATED AT THE MAIN CONTROL PANEL AND SHALL BE CONNECTED TO A DEDICATED INITIATING CIRCUIT THAT IS NOT INCLUDED IN ANY PANEL TEST MODE TO MEET THE REQUIREMENTS OF

NFPA 72, PARAGRAPH 23.8.5.1.2.

14. THE STROBE CANDELA INTENSITIES SHALL BE ADJUSTED AS REQUIRED.

15. PROVIDE SYNCHRONIZED STROBE OPERATION IN AREAS WHERE THE STROBING ACTION FROM TWO OR MORE

STROBE APPLIANCES ARE VISIBLE (WHICH MAY INCLUDE MORE THAN ONE ROOM).

16. SEE SHEET FA501 FOR FIRE ALARM AND MASS NOTIFICATION TRANSCEIVER MOUNTING DETAL AND LOCAL

OPERATING CONSOLE (LOC) DETAIL.

17. NOTIFICATION DEVICES SHALL BE ADDRESSABLE OR SHALL BE CIRCUITED AS REQUIRED FOR THE ACTIVATION OF THE FUNCTIONS INDICATED ON THE FIRE ALARM PLANS, THE FIRE ALARM/MASS NOTIFICATION SYSTEMS OPERATION MATRIX, AND SPECIFICATION SECTION 28 31 76: INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM.

18. SPEAKER BACKBOXES SHALL BE PROVIDED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.

19. THE PAGING SYSTEM SHALL SUPPORT TELEPHONE CALL-IN INPUT VIA AN INTEGRAL ZONED TELEPHONE PAGING INTERFACE MODULE. ACTIVATION OF THE TELEPHONE PAGING MODULE SHALL TRANSMIT THE VOICE INPUT THROUGH THE MASS NOTIFICATION SPEAKERS. PAGING WILL NOT ACTIVATE ANY ADDITIONAL FAMNSCP FUNCTIONS.

20. THE FIRE ALARM AND MASS NOTIFICATION SYSTEM SHALL SEND A SIGNAL TO BYPASS LIGHTING CONTROL DEVICES IN THE MEANS OF EGRESS, TURNING CONTROLLED LUMINAIRES TO FULL OUTPUT. SEE NFPA 101 PARA 7.8.1.2.2.

21. SEE ARCHITECTURAL PLANS FOR LOCATION OF KNOX BOX. THE KNOX BOX TAMPER SIGNAL SHALL BE SENT TO THE FIRE DEPARTMENT VIA THE FIRE ALARM TRANSMISSION MEDIA ON A ZONE SEPARATE FROM ANY OTHER ALARMS

OR SUPERVISORY INDICATION.

22. PROVIDE END-OF-LINE RESISTERS PER CLASS "B" REQUIREMENTS.

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXDGV\Documents\FY18JA76149_RECEPTION COMPLEX_MEP_R21_K6ENXDGV.rvt

5/3/2024 1:52:11 PM

JU

N

E

W

2H P1

9R

M . B

R

EN

N

AN

P.

S

U

LL

IV

AN

2-

-0

FA601

FI

R

E

AL

AR

M

, M

AS

S N

O

TI

FI

C

AT

IO

N A

N D

P

AG

IN

G

SY

ST

EM

D

IA

G

R

AM

A N

D N

O

TE

S

H

AG

O

O D

A

VE

N U

E C

H

AR

LE

ST

O N

D

IS

TR

IC

T C

H

AR

LE

ST

O N

, S O

U

TH

C

AR

O

LI

N A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

SA

VA

N

N

AH

D

IS

TR

IC

T

W

. O G

LE

TH

O R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T

JA

C

KS

O N

, S O

U

TH

C

AR

O

LI

N A

R

EC

EP

TI

O N

C O

M

PL

EX

P

H

AS

E

FY

8, P

N

VO

LU

M E

-C

LO

TH

IN

G

IN

IT

IA

L

IS

SU

E

PO

IN

T

(C

IIP

T.

F

U N

K

ISSUE FOR CONSTRUCTION

SINGLE LINE DIAGRAM: FA-MN-PA SYSTEM1

GENERAL NOTES: FA-MN-PA SYSTEM2 REFERENCED NOTES: FA-MN-PA DIAGRAM3

M

AR

K D

ES

C

R

IP

TI

O

N D

File details come from the government source that posted it. Updated .