Attachment_15,_Re-issued_Drawings.pdf

PDF 35 MB Posted

Attached to
VA Livermore Phase B, Construct Community Based Outpatient Clinic, and Central Utility Plant, Stockton, CA
Solicitation number
W91238-18-R-0056
Issued by

About this file

Attachment 15 - Reissued Drawings

View the file

Other files

File Type Posted
Attachment_20_-_Reissued_Specs_.pdf PDF
Amendment_0004.pdf PDF
Attachment__19_-__Re-issued_Drawings.pdf PDF
Attachment_17_Construction_Temporary_Utilities_Service_Point-of-Connection,_City_of_Stockton.pdf PDF
Attachment_18_-_Wage_Determination.pdf PDF
W91238-18-R-0056-_Amendment_0003.pdf PDF
W91238-18-R-0056_Conformed_Copy.pdf PDF
CBO-_CUP_-_Siemens_Brand_Name_J&A.pdf PDF
Attachment_16_-_Specifications_revised_and_new_issued.pdf PDF
Attachment_(13)_Re-Issued_Specifications_01_50_01,Revised_8Nov18(LT8Nov18).pdf PDF
W9123818R0056_Amendment_0002.pdf PDF
W9123818R0056_Conformed_Copy_Amendment.pdf PDF
Attachment_14__Re-issued_Drawings.pdf PDF
Attachment_(12)_Specifications-working.pdf PDF
Attachment_(11)_Office_Complex_and_Contractor_Laydown_(05NOV).pdf PDF
A03.10_Final_Stockton_Phased_B_Combined_JA_for_posting_Redacted.pdf PDF
Attachment_(10)_RMS_Submittal_Register(5Nov18).xlsx XLSX spreadsheet
Attachment_(09)_AE_Drawing_Revisions_.pdf PDF
W9123818R0056_Amendment_0001.pdf PDF
Phase_B_Site_Visit_Sign-In_Sheets.pdf PDF
W9123818R0056_Stockton_CBOC_and_CUP_Solicitation.pdf PDF
ATTACHMENT_7_-_APPENDIX_B_-_EQUIPMENT_CUT_SHEETS.pdf PDF
ATTACHMENT_5_-_DRAWINGS_VOLUME_B3.pdf PDF
ATTACHMENT_1_-_STATEMENT_OF_WORK.pdf PDF
ATTACHMENT_3_-_DRAWINGS_VOLUME_B1.pdf PDF
ATTACHMENT_6_-_APPENDIX_A_-_GEOTECHNICAL_ENGINEERING_REPORT.pdf PDF
ATTACHMENT_2_-_SPECIFICATIONS.pdf PDF
ATTACHMENT_8_-_WAGE_DETERMINATION.pdf PDF
ATTACHMENT_4_-_DRAWINGS_VOLUME_B2.pdf PDF
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CLARIFICATIONS

ARCHITECTURE/

INTERIOR DESIGN/

SECURITY/SIGNAGE/

COMMUNICATIONS/ MEDICAL

EQUIPMENT/ MASTER PLAN

LANDSCAPE/

ENVIRONMENTAL

ASSESSMENT:

HDR Architecture, Inc.

201 California Street, Suite 1500 San Francisco, CA 94111 o n e e i g h t h i n c o e f o t o n e q u a r t e r i n o t t h r e e e i g h t o t o n e h a l f i n o t t h r e e q u a r t e r s o t o n e i n o t o n e a d e h a l f i n o t t h r e e i n c h s o t

Drawing number

Drawn

Location

Project Title

Date Checked by

Drawing Title

1 2 3 4 5 6

A

B

C

D

E

F

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

CONSULTANTS: ARCHITECTS/ENGINEERS: Office of Construction and Facilities Management

7 8 9

MECHANICAL/ELECTRICAL/

PLUMBING:

Gayner Engineers 1133 Post Street San Francisco,CA 94109

STRUCTURAL:

Degenkolb Engineers 375 Beale Street Suite 500 San Francisco, CA 94105

CIVIL / SURVEYOR:

Sandis 636 9th Street Oakland, CA 94607

FULLY SPRINKLERED

FIRE PROTECTION:

Jensen Hughes Inc.

2950 Buskirk Avenue, Ste. 225 Walnut Creek, CA 94597

CONSULTANT:

GEOTECHNICAL:

Allegiance Group 4321 SW Corbett #200 Portland, OR 97239

COST ESTIMATING:

AECOM

300 California Street, Suite 400 San Francisco, CA 94104

Station Number Project Number

640 640-423

Building Number

U.S. Department of Veterans Affairs

VA Livermore Realignment and Closure - Part B - CBOC

Stockton (French Camp) San Joaquin County, CA

NO REVISIONS DATE

800 (CBOC), 803 (CUP)

0'-7

1'-9

3 4

7'-1

4'-3

FREESTANDING GLIDE

OPTIONAL UMBRELLA HOLE

Ø42 SOLID TABLE TOP,

POWDER COATED STEEL

PLAN VIEW

SIDE ELEVATION ISOMETRIC VIEW

MOUNTING DETAIL

OPTIONAL SURFACE MOUNT

TAB Ø7/16" HOLES FOR

ANCHORING HARDWARE NOT

INCLUDED

NOTES:

1. LANDSCAPE FORMS CAROUSEL - OR APPROVED EQUAL

2. ADA OPTION: 5-SEAT, GRID, DINING HEIGHT

3. NON-ADA OPTION: SIMILAR AS ABOVE, 6-SEAT, GRID, DINING HEIGHT

4. SEE HARDSCAPE PLANS FOR LAYOUT

1 1/2" = 1'-0"

TRASH RECEPTACLE - FOR REFERENCE ONLY

"x

" STEEL BAR

" SCHEDULE 40 STEEL PIPE (1

"Ø)

"Ø

HOLE

3 8

"x2

" SS FLAT

SOCKET HD

CAP SCREW

CAST

LEG

73"

"x1

" STEEL BAR

75"

END ELEVATION FRONT ELEVATION

ISOMETRIC VIEW

NOTES:

1. LANDSCAPE FORMS SCARBOROUGH BENCH: 72" BACKED,

WITH ARMS - OR APPROVED EQUAL

2. INSTALLATION PER MANUFACTURER'S SPECIFICATIONS

3. CONFIRM LOCATION AND FACING SIDE PRIOR TO SECURING

4. SEE HARDSCAPE PLANS FOR FINISH SURFACE & MATERIAL

2 1/4" = 1'-0"

SITE BENCH - FOR REFERENCE ONLY

3 8

1'-0

2'-0

3 4

VERTICAL

STRAP BASKET

INSERT

SURFACE

MOUNT

LIFT AND TURN

LID TO EMPTY

FRONT ELEVATION

PLAN

SIDE ELEVATION

NOTES:

1. LANDSCAPE FORMS SCARBOROUGH RECEPTACLE, SIDE

OPENING - OR APPROVED EQUAL

2. INSTALLATION PER MANUFACTURER'S SPECIFICATIONS

3. CONFIRM LOCATION AND FACING SIDE PRIOR TO SECURING

3 NTS

FLAG POLE

4 1/2" = 1'-0"

BICYCLE RACK - FOR REFERENCE ONLY

5 1/2" = 1'-0"

REMOVABLE BOLLARD

6 1/2" = 1'-0"

TABLE AND CHAIRS - FOR REFERENCE ONLY

8 1/2" = 1'-0"

PEDESTRIAN/SWING GATE - STEEL

1 3/4" RAIL

2 1/2" POST OR PER

MANUFACTURER'S

RECOMMENDATION

8' OC NOM

2"

NOM

S

T A

N D

A R

D

0'-1"

M

I N

3 3/4"

TYP

1"Ø 16 GA PICKET

FINISH GRADE

BRACKETS/ATTACHMENTS

PER MANUFACTURER'S

RECOMMENDATION

NOTES:

1. AMERISTAR MONTAGE INDUSTRIAL MAJESTIC -

OR APPROVED EQUAL

2. ALL DIMENSIONS NOMINAL

3. POST SIZING PER MANUFACTURER'S

RECOMMENDATION

4. ATTACHMENTS PER MANUFACTURER'S

RECOMMENDATIONS

5. SEE HARDSCAPE PLANS FOR LAYOUT

18"

3" LATCH

CLEARANCE

5'-0"

2" HINGE

CLEARANCE

0'-1"

M

I N

2"

NOM

1 3/4" RAIL

2 1/2" POST OR PER

MANUFACTURER'S

RECOMMENDATION

GATE POST

2"x11 GA OR PER

MANUFACTURER'S

RECOMMENDATIONS

NOTES:

1. AMERISTAR MONTAGE INDUSTRIAL MAJESTIC - OR APPROVED EQUAL

2. ALL DIMENSIONS NOMINAL

3. POST SIZING PER MANUFACTURER'S RECOMMENDATION

4. ATTACHMENTS PER MANUFACTURER'S RECOMMENDATIONS

5. SEE HARDSCAPE PLANS FOR LAYOUT

6. LATCHES, HINGES, AND MISCELLANEOUS HARDWARE PER MANUFACTURER

1"Ø 16 GA PICKET

3 3/4"

TYP

WELD ON BOX HINGE

FINISH GRADE

18"

1/4" = 1'-0"

CHAINLINK FENCE

11 1/2" = 1'-0"

FIXED K4 RATED BOLLARD

10 1/2" = 1'-0"

SCREEN FENCE

VARIES, SEE

HARDSCAPE PLANS

"1'-2"

GATE MOUNTING

POST, TYP

FENCE LINE

FENCE POST

POST, TYP

FENCE LINE

VARIES, SEE

HARDSCAPE PLANS

NOTES:

1. AMERISTAR TRANSPORT II MAJESTIC - OR APPROVED EQUAL

2. ALL DIMENSIONS NOMINAL

3. POST SIZING PER MANUFACTURER'S RECOMMENDATION

4. ATTACHMENTS PER MANUFACTURER'S RECOMMENDATIONS

5. SEE HARDSCAPE PLANS FOR LAYOUT

6. SEE SPECIFICATIONS FOR AUTOMATED GATE OPERATORS

7. LATCHES, HINGES, AND MISCELLANEOUS HARDWARE PER MANUFACTURER

FRONT ELEVATION

SIDE

ELEVATION

PLAN VIEW

FINISH GRADE

18"

24"

24"

48"

4" - 14 GUAGE SPUN

ALUMINUM BALL. GOLD

ANODIZED.

3" CAST ALUMINUM

STATIONARY TRUCK

1 SET OF HALYARD, #10

POLY

2 BRONZE SWIVAL SNAPS

WITH COVERS

1- 9" CAST ALUMINUM

CLEATS

ALUMINUM FLASH

COLLAR

3000 PSI CONCRETE

HARDWOOD WEDGES

DRY SAND TIGHTLY

TAMPED AFTER ALIGNING

POLE

FOUNDATION SLEEVE -

16 GUAGE HOT DIP

GALVANIZED STEEL

STEEL CENTERING

WEDGES

" STEEL BASE PLATE

" STEEL SUPPORT

PLATE WELDED TO

GROUNDING SPIKE

P O

L E

L

E N

G T

H

FOUNDATION

DESIGN AND

ANCHORAGE BY

MANUFCATURER'S

ENGINEER PER

SPEC 107500

STRETCHER BAR W/

BAR BANDS, TYP

9 GAUGE CHAINLINK FABRIC,

VINYL COATED, BLACK

END POST, TYP

10'-0" OC MAX

LINE POST, TYP

POST TOP, TYP

TOP RAIL, TYP

WIRE TIES, TYP

MAX 18" OC

L I N

E

P

O S

T

E N

D

P

O S

T

3"

9 GA BOTTOM

TENSION WIRE, TYP

LINE POST: 8"Ø

END POST: 12"Ø

FINISH GRADE

CONCRETE FOOTING,

REINFORCEMENT PER

STRUCTURAL

2" MAX

9 1/4" = 1'-0"

VEHICULAR SLIDING GATE - STEEL

2'-1

Ø1 1/2" TUBING

15°

1 4

R6

SIDE ELEVATION

PLAN

FRONT ELEVATION

NYLON GLIDES

ON BOTTOM OF

CURVED TUBE

FINISH GRADE

AXO VIEW: SURFACE-MOUNT TAB

2 SURFACE-MOUNT

TABS WITH 7/16" HOLES

FOR ANCHORING;

NON-CORROSIVE

ANCHORING HARDWARE

NOT INCLUDED; REFER

TO INSTALLATION GUIDE

FOR MORE DETAILS

NOTES:

1. LANDSCAPE FORMS FLO BIKE RACK OR APPROVED EQUAL

2. INSTALL PER MANUFACTURER'S RECOMMENDATIONS

3. 36" MIN CLEAR BETWEEN ADJACENT STRUCTURES OR RACKS; 48" MIN CLEAR

BETWEEN ROWS OF RACKS

SECTION

21"

#4 REBAR STIRRUPS

& HORIZONTAL

REINFORCEMENT

EMBEDMENT

SLEEVE &

HINGING

LID

PLAN - LID CLOSED

Ø10.25"

CAMLOCK

NOTES:

1. SSR05000 CALPIPE REMOVABLE INTERNAL LOCKING

BOLLARD - OR APPROVED EQUAL

2. INSTALLATION PER MANUFACTURER'S RECOMMENDATIONS

3. FOUNDATION SHOWN IS FOR NON-RATED BOLLARDS. AT

IMPACT, RATED BOLLARDS PROVIDE FOUNDATIONS PER

MANUFACTURER'S REQUIREMENTS BASED ON TESTING OR

PROVIDE AN ENGINEERED DESIGN. SUBMIT FOUNDATION

DESIGN FOR REVIEW AND APPROVAL.

LID

NOTES:

1. PDT08080F STAINLESS STEEL CALPIPE HIGH SECURITY FIXED

BOLLARD - OR APPROVED EQUAL

2. CLEAR SPACING BETWEEN BOLLARDS: 48" MIN

3. INSTALLATION PER MANUFACTURER'S RECOMMENDATIONS.

4. PROVIDE FOUNDATIONS PER MANUFACTURER'S REQUIREMENTS

BASED ON TESTING OR PROVIDE AN ENGINEERED DESIGN. SUBMIT

FOUNDATION DESIGN FOR REVIEW AND APPROVAL.

SECTION VIEW

8 5/8"

36"

DRAIN

FIXED BOLLARD

BOLLARD 8" SCH 80

CONCRETE FILLED

DIRECTION OF

IMPACT

#4 REBAR STIRRUPS

& HORIZONTAL

REINFORCEMENT

12 1/2" = 1'-0"

REMOVABLE K4 RATED BOLLARD

NOTES:

1. PDT08080R STAINLESS STEEL CALPIPE HIGH SECURITY REMOVABLE

BOLLARD WITH WING NUT AND LIFTING EYE - OR APPROVED EQUAL

2. CENTER ON CENTER SPACING: 48" MAX

3. INSTALLATION PER MANUFACTURER'S RECOMMENDATIONS.

4. PROVIDE FOUNDATIONS PER MANUFACTURER'S REQUIREMENTS

BASED ON TESTING OR PROVIDE AN ENGINEERED DESIGN. SUBMIT

FOUNDATION DESIGN FOR REVIEW AND APPROVAL.

SECTION VIEW

8 5/8"

36"

DRAIN

REMOVABLE

BOLLARD 8" SCH 80

CONCRETE FILLED

DIRECTION OF

IMPACT

#4 REBAR STIRRUPS

& HORIZONTAL

REINFORCEMENT

WING NUT AND

LIFTING EYE

ASSEMBLY

1 DESIGN 19 NOV 18

AM-0003

11-19-18

LEVEL 1

0' - 0"

LOADING DOCK

3'-

CL

EA

R

'-0

DOCK LEVELER, VERIFY

PIT SIZE WITH MFR.

TRENCH DRAIN

RE: CIVIL

DOCK BUMPERS

GUARDRAIL

BEYOND

1' - 0"

7' - 2"

1'- 7 5

/8"

ZY

STANDING SEAM METAL ROOF

- 1/4" PER FOOT MIN SLOPE

BUILDING PAPER ON

WATERPROOFING MEMBRANE ON

3/4" MOISTURE TREATED PLYWOODSIM.

A-822 E2

Sim

STEEL DECK RE: STRUCT GALVANIZED FINISH

6" x 6" RECTANGULAR GUTTER, TYP

DOWNSPOUT

METAL THROUGH WALL

FLASHING ON STANDING

SEAM METAL ROOF

STANDING SEAM END

CLOSURE CHANNEL PER

MANUF. STANDARD DETAIL

(fla sh ing

1'

- 0

GUARDRAIL, TYP

FOR EMBEDDED PIPE SLEEVE AT

RAILING REFER TO STRUCTURAL DETAIL

11 63/64" min5"

5" CLEAR BETWEEN CANOPY

AND FACE OF WALL

TYP PANEL WIDTH

3'-0"

GALVANIZED HSS 5X5X3/16 TUBE STEEL POST

TYP

12'-0"

E1

AS501

TYP

ES 3/16"

6" 6"

6'- 0"

6" 6"

3" DEEP (22GA) RIBBED, PRE-

FINISHED, METAL PANEL

REFER TO SPEC'S FOR

ANCHORAGE AND

ATTACHMENT REQ'S

GALVANIZED HSS 4X4X3/16

HORIZONTAL TUBE STEEL

SUB FRAME

GALVANIZED HSS 5X5X3/16

TUBE STEEL POST

8'- 0"

E2

AS501

GALVANIZED HSS 4X4X3/16

HORIZONTAL TUBE STEEL SUB

FRAME

3" CLR

4 - #4'S

2 TIGHT TURNS T&B

#3 SPIRAL w/ 6" PITCH

FINISHED GRADE

2' - 0"

6'

- 6

2'

- 0

" M

IN

LEVEL 1

0' - 0"

C22

A1

AS501

3'- 7"

DOCK LEVELER, TYPDOCK BUMPERS

GUARDRAIL, TYP

FOR EMBEDDED PIPE SLEEVE AT

RAILING REFER TO STRUCTURAL DETAIL

CHAIN RAIL

A7

AS501

Z3Z2Z1

DOWNSPOUT DOWNSPOUT

CONCRETE POST

RE: CIVIL

LEVEL 1

0' - 0"

(7 ) R

IS

ER

S 3'-

1/

2" (h an d ra il)

3'- 0"

2'-0"

(6) TREADS @ 11"

5'-6" 1'-4"

Y

(g ua rd ra

il) 3'

- 6

5/2

"1 1/2" DIA. PAINTED STEEL

PIPE RAIL AND COLUMN,

TYPICAL

LEVEL 1

0' - 0"

LEVEL 2

15' - 0"

W X

A-822 E2

Sim

STANDING SEAM METAL ROOF

- 1/4" PER FOOT MIN SLOPE

6" X 6" RECTANGULAR GUTTER

STEEL COLUMN AND BEAM

RE: STRUCTURE

GALVANIZED FINISH

A6 A-822

Sim

AT WALL

0"

BUILDING PAPER ON

WATERPROOFING MEMBRANE ON

3/4" MOISTURE TREATED PLYWOOD

ON METAL DECK W/ GALV. FINISH

LO

W S

ID

E

'-9

1/ 2"

T .O

. B

EA

M

ALUMINUM POST 3x3x3/16, TYP.

REINF NOT

SHOWN FOR

CLARITY

16" DIA.

5'

- 0

" F

OR

S

IG

N

EN

-0 1.0

4'

- 0 " T

YP

IC

AL

3"3" CLR

4 - #4'S

2 TIGHT TURNS T&B

#3 SPIRAL w/ 6" PITCH

FINISHED GRADE

" M

IN

3 1 /2"

2"

IN LANDSCAPED AREAS, FOOTING

SHALL BE BOXED SO AS TO EXTEND

3 1/2" ABOVE GRADE WITH 2" BEVEL.

REPLACE SURROUNDING

LANDSCAPE TO ORIGINAL

CONDITION.

APPLY PROTECTIVE COATING TO ALL

ALUMINUM POSTS IN CONCRETE TO

PREVENT CORROSION

3'

- 6

1'

- 2

1'

- 2

GALVANIZED 1-1/2"

STANDARD STEEL PIPE

RAILING TYPICAL

RETAINING WALL WITH

SLEEVES FOR POSTS. REFER

TO STRUCTURAL DRAWINGS

RAIL POST AT 5'-0" O.C. MAX.

EXPANSION SLEEVES AT

30'-0" MAX. PROVIDE 1/2"

EXPANSION AT EACH

LOCATION.

SECTION ELEVATION

on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot th re e-ei gh th in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot

6" on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot th re e in ch es o ne fo ot

6"

6"

6"

Drawing number

Drawn

Location

Project Title

Date Checked by

Drawing Title

1 2 3 4 5 6

A

B

C

D

E

F

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

CONSULTANTS: ARCHITECTS/ENGINEERS: Office of Construction and Facilities Management

7 8 9

MECHANICAL/ELECTRICAL/

PLUMBING:

Gayner Engineers 1133 Post Street San Francisco,CA 94109

STRUCTURAL:

Degenkolb Engineers 375 Beale Street Suite 500 San Francisco, CA 94105

CIVIL / SURVEYOR:

Sandis 636 9th Street Oakland, CA 94607

ARCHITECTURE/

INTERIOR DESIGN/

SECURITY/SIGNAGE/

COMMUNICATIONS/ MEDICAL

EQUIPMENT/ MASTER PLAN

LANDSCAPE/

ENVIRONMENTAL

ASSESSMENT:

HDR Architecture, Inc.

201 California Street, Suite 1500 San Francisco, CA 94111

FULLY SPRINKLERED

FIRE PROTECTION:

Jensen Hughes 2950 Buskirk Avenue | Suite 225 Walnut Creek, CA 94597

CONSULTANT:

GEOTECHNICAL:

Allegiance Group 4321 SW Corbett #200 Portland, OR 97239

COST ESTIMATING:

AECOM

300 California Street, Suite 400 San Francisco, CA 94104

Station Number Project Number

640 640-423

Building Number

U.S. Department of Veterans Affairs

RS

N:

//o ma c-i nr ev itp

/20

-V A/

_L ive rm or e_

Re ali gn me ntA nd

Cl os ur e/A

R/

_B -C

BO

C_

Ce ntr al.

rvt

/15

/20

2:

:02 P

M

AS501

SITE SECTIONS

Checker Author03 JULY 2018

VA Livermore Realignment and Closure - Part B - CBOC

Stockton (French Camp) San Joaquin County, CA

800 (CBOC), 803 (CUP)

1/4" = 1'-0"A1 SECTION LOADING DOCK

1/2" = 1'-0"E2 SITE SCREEN WALL - PLAN

1/2" = 1'-0"E1 SITE SCREEN WALL - SECTION

1/4" = 1'-0"C1 LOADING DOCK ELEVATION

1/4" = 1'-0"A7 SECTION LOADING DOCK1

1/4" = 1'-0"A9 SECTION CANOPY

1/2" = 1'-0"E3

SITE SIGNAGE & INTERCOM

STANCHION SECTION (TYP)

(SINGLE POLE SIM.)

NO REVISIONS DATE

1 DESIGN CLARIFICATIONS 19 NOV 18

3/4" = 1'-0"E8 SITE WALL RAIL

AM-0003

S:S:

UP

E F G H J K L M

A2 A-304

A6 A-308

A8 A-308

A4 A-304

A2 A-305 A6

A-304

A8 A-306

1A106H

SRS01

190 SF

STOR,

BULK

1A131

BX001

859 SF

COFFEE

SHOP

1A106B

LMCH3

1095 SF

HEMATOLOGY

LAB

1A106D

SRS04

76 SF

STOR

PHLEBOTOMY

1A106K

TLTU1

62 SF

TLT-URIN

1A112

ITNT1

434 SF

MDF RM

1A106

WRC01

321 SF

WAIT, LAB

1A106A

LBVP1

798 SF

BLOOD

SPECIMEN

COLLECTION

1A107E.1

TLTU1

72 SF

PAT TLT

1A107E

XDUS1

185 SF

ULTRASOUND

1A107M

UCCL1

115 SF

CLEAN

UTIL

1A107G

XDR01

324 SF

RADIOLOGY

1A107H

XDR01

325 SF

RADIOLOGY

1A110

USCL1

114 SF

SOILED

UTIL

1A107C

TLTU1

67 SF

PAT TLT

1A107G.1

DR001

64 SF

DRESSING

RM

1A107H.3

DR001

65 SF

DRESSING

RM

1A107H.1

OFDR1

129 SF

OFFICE

1A107B

SRHM1

47 SF

STRETCHER

HOLD

1A137

CRA03

363 SF

SHARED

MED APPT

1A138A

OFA03

360 SF

PATIENT

RESOURCES

1A105

WRC01

338 SF

PHARMACY

WAIT

1A106J

TLTU1

74 SF

ST TLT

1A106F

SRR02

34 SF

DI WATER

1A106C

LBVP1

101 SF

PRIVATE

DRAW

1A107A.1

MRS01

80 SF

DOCUMENT

CONTROL

C1111

289 SF

CORR

1A107

WRC01

140 SF

WAIT,

RADIOLOGY

1A107D

DR001

63 SF

DRESSING

RM

1A113

OFA03

330 SF

OFF,

SHARED

1A113E

ITWR1

183 SF

COMPUTER

REP/ STOR

1A113B

TEDR1

139 SF

SW RM

1A113D

SRE01

150 SF

SUPPLY

STOR

1A105R

PHOD1

141 SF

INTAKE

1A105S

PHOD1

141 SF

INTAKE

1A105H

TLTU1

68 SF

ST TOILET

1A105G

PHOD2

256 SF

RECEIVING

BREAKDWN

1A105F

SL001

362 SF

ST LKRS,

LOUNGE

1A105N

PHOD2

336 SF

VAULT,

CONTROLLED

SUBSTANCE

WORK

AREA

1A105K

OFD03

123 SF

OFFICE,

SUPV.

1A105L

PHIV2

149 SF

ASEPTIC

(CLEANROOM)

1A105M

PHIV2

185 SF

ANTE

1A105C

563 SF

CIRCULATION

1A105A

2446 SF

PHARMACY

WORK

AREA

1A106L

TLTU1

62 SF

TLT-URIN

1A106M

97 SF

VEST

C1102

847 SF

CORR

1A134

CRA03

344 SF

SHARED

MED APPT

1A107H.2

185 SF

VEST

1A107G.2

185 SF

VEST

1A102

TLTF2

271 SF

TLT

PUBLIC F

1A104

TLTM2

250 SF

TLT

PUBLIC M

1A100B

RECP3

200 SF

INFO/

RECEP

DESK

1A138

WRC01

340 SF

WAIT

1A101

252 SF

VEST

1A138E

EYFD1

288 SF

FITTING

AND

DISPENSING

1A136

CRA03

372 SF

SHARED

MED APPT

1A135

CRA03

351 SF

SHARED

MED APPT

1A134A

SRE01

160 SF

COMMAND

CENTER

STOR

1A132

129 SF

KITCHENETTE

1A122

LAC01

79 SF

LACTATION

1A107A

CMP01

118 SF

TECH

WORKRM

1A107G.4

CMP01

142 SF

CONTROL/

TECH

WORKRM

1A107J

XDM01

182 SF

MAMMOGRAPHY

1A107L

WRC01, WRF01

55 SF

MAMMO

WAIT

1A107K

DR001

51 SF

MAMMO

DRESSING

1A100D

SRLW1

87 SF

WHEELCHAIR

STOR

A-401 D3

A-404 C3

A-450 A7

A-440 A7

A-411 C8

1A100

485 SF

LOBBY

P-1

110 SF

ELEV P-1

P-2

104 SF

ELEV P-2

P-3

110 SF

ELEV P-3

1S001

277 SF

STAIR 1

C1103

1670 SF

CORR

C1110

1066 SF

CORR

1A138F

12 SF

ELEC

C1105

2722 SF

CORR

1A106N

9 SF

ELEC

C1100

2576 SF

CORR

A-220

A1

A7 B7

B1

1A

7E .1

1A

5C

C

1A107C

1A107J 1A107L

1A106L1A

6K

1A

5N

1A105K

1A105F 1A

5G

1A

5S .1

1A

5R .1

1A105S.21A105R.2

1A

5A T.

1A

7D A

C

A

1A107DB

1A

6C

1A106D

1A

6A C

1A

6A D

1A106J

1A106H 1E

1A

C1103

1A135

1A134

1A136

1A137

1A

4A

1A107A

1A107E

1A107G.1A1A107G.1B

1A107G

1A

7G .4

B

1A107H.3A1A107H.3B

1A107H

1A107H.1A

1A

7G .4

A

1A107M

1A

1A105H

1A106N

1A138F

1S001A

D1 A-301

A1 A-301

1A138G

WRC01

210 SF

WAIT

FEC-1

FEC-1/

A1

A-10 1-C /A1 A-101-B

A1

A- 1 0

1- C

MAIN

ENTRANCE

A-220 B8

7.2

N

6.8

1A106P

7 SF

F.A. CLO.

1A106P

A-202D

A-201

C1

1A147

WRC01

250 SF

WAIT

O.H.

PRPS-1

CWS-1

CWS-2

CWS-2

CWS-2

CWS-2

CWS-2

MPRS-1

CWS-1

MPRS-2

CWS-1 MPRS-2

MPRS-2

CWS-2 MPRS-1

05-01

05-01

1A101B

1A101A

A-220

E1

A-220

D1

C1 D6

1A

1A

1S

1B

1A

1A

1A

6M

C

FEC-1

FEC-1

FEC-1 FEC-1

FEC-1

FEC-1

1A100E

880 SF

CIRCULATION

1A146Y

200 SF

KIOSKS

C1103A

A-406 E3

A-406 D3

A-406 A3

1A134.1

1A136B

A-411 E3

A-406 B8

A-407 A1

A-407 C3

A-407

1A

FLOOR DRAIN

1A

5M

OFF CHIEF

1A149B

OFA03

A-830 C6

A-810 E8

Sim

A-830 E8

Sim

A-830 C8

Sim

A-222E4

H.2

C1102B

A-222

E2

IW02

IW

IW

IW01

IW05

IW06

IW

IW07

A-402

SIMD7

D5

D8

A-402

SIM D7

D5

D8

A-830 E8

Sim

IW04

1A105T.1

OFDC2

123 SF

PICK-UP

NOTE: COUNTER TO BE

INSTALLED AT 2' - 10" AFF.

(6) LOCKERS

A-402

SIMD5

D7

A-810 A5

OPP

OPP

D8

OPP

1A112

ITNT1

434 SF

MDF RM

1A112A

1A

3B

1A

1A

1A

6A A

1A

6A B

1A105L

1A130

MODULAR PARTITION

SYSTEMA-222 C6 A-222

B7

AIR PRESSURE

GAUGE

MONITOR

DOOR

ACTUATOR

1A131A

1A146Z

320 SF

URINALYSIS

C5

A-406

A6

A-222E5

E7

1A107K

C1112

51 SF

CORR

8.4

1A

1A

1A106E

LMBB1

154 SF

BLOOD

BANK

1A

1A145E

A-412 A1

A-410

D1

D2

1A106E

INTERMEDIATE

LANDING

NON RATED PARTITION

1 HOUR FIRE BARRIER WALL

2 HOUR FIRE BARRIER WALL

LEAD LINED PARTITION

PARTITION SYMBOLS

REFER PLANS FOR TYPES

AND TO SHEET A-601 FOR INFORMATION

NON RATED SMOKE PARTITION

MODULAR PARTITION (U.N.O.)

CMU + GWB PARTITION

GENERAL NOTES:

1. REFER TO A-100 SERIES DIMENSION SHEETS FOR

OVERALL DIMENSIONS AND PARTITION TYPES

2. REFER TO A-400 SERIES FOR ENLARGED PLANS

3. REFER TO A-03 FOR TYPICAL MOUNTING HEIGHTS AND

ABA REQUIREMENTS

4. REFER TO A-200 SERIES FOR INTERIOR ELEVATIONS

5. REFER TO A-401, A-402 AND A-404 FOR TYPICAL TOILET

ROOM LAYOUTS; REFER TO A-405 FOR TYPICAL AND

REPEATING ROOMS INCLUDING BUT NOT LIMITED TO

CONSULT/ EXAM AND PROCEDURE ROOMS, NOTE THAT

EYE TESTING ANTERIOR, EYE LASER TREATMENT,

PHOTOGRAPHY, SPEECH ANALYSIS, IMMITTANCE, AND

TREAT-OPHTHA ARE TO ALSO REFERENCE THESE

ROOMS FOR TYPICAL LAYOUTS.

6. REFER TO A-700 SERIES FOR RCPS

7. REFER TO A-502 FOR CEILING DETAILS

8. REFER TO A-520 FOR CASEWORK DETAILS

9. REFER TO AI SERIES FOR INTERIOR FINISHES

10. FURNITURE, ACCESSORIES, AND EQUIPMENT SHOWN

FOR REFERENCE ONLY; REFER TO EQ SERIES

DRAWINGS FOR SCHEDULE AND QUANTITIES NOT

SPECIFICALLY SHOWN ON A-100 SERIES PLANS. FOR

LOCATION OF THESE ITEMS REFER TO SHEET A-03 FOR

TYPICAL MOUNTING HEIGHTS AND ABA REQUIREMENTS.

FOR TYPICAL ACCESSORIES REFER TO DETAILS A7 &

C1, U.N.O.

11. REFER TO FJ SERIES, LIFE SAFETY PLANS, FOR

LOCATIONS OF REQUIRED RATED WALLS, SMOKE

PARTITIONS, AND SMOKE BARRIERS, IF CONFLICT

EXISTS USE MOST RESTRICTIVE

12. REFER TO A-603 FOR GENERAL BLOCKING NOTES FOR

TYPICAL METAL STUD BLOCKING AND METAL STUD

FRAMING REQUIRED.

13. REFER TO SHEET QH-A600 FOR SPECIFIC LOGISTICS

CATEGORY OF EQUIPMENT ITEMS, ALL ITEMS ARE TO

BE ASSUMED TO BE C/C UNLESS SPECIFICALLY LISTED

OTHERWISE ON SHEET QH-A600 REGARDLESS OF

GRAPHIC REPRESENTATION.

14. MODULAR PARTITIONS V/V - GOVERNMENT FURNISHED/

GOVERNMENT INSTALLED, REQUIRE COORDINATION

WITH ELECTRICAL, SECURITY, TELECOM, AND

HARDWARE FOR INCORPORATION OF CONDUIT AND TO

SUPPORT WIRING AND DEVICES - TYPICAL.

D

B

C A

0 4'-0" 8'-0" 16'-0"

PLAN

NORTH

on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot th re e-ei gh th in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot

6" on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot th re e in ch es o ne fo ot

6"

6"

6"

Drawing number

Drawn

Location

Project Title

Date Checked by

Drawing Title

1 2 3 4 5 6

A

B

C

D

E

F

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

CONSULTANTS: ARCHITECTS/ENGINEERS: Office of Construction and Facilities Management

7 8 9

MECHANICAL/ELECTRICAL/

PLUMBING:

Gayner Engineers 1133 Post Street San Francisco,CA 94109

STRUCTURAL:

Degenkolb Engineers 375 Beale Street Suite 500 San Francisco, CA 94105

CIVIL / SURVEYOR:

Sandis 636 9th Street Oakland, CA 94607

ARCHITECTURE/

INTERIOR DESIGN/

SECURITY/SIGNAGE/

COMMUNICATIONS/ MEDICAL

EQUIPMENT/ MASTER PLAN

LANDSCAPE/

ENVIRONMENTAL

ASSESSMENT:

HDR Architecture, Inc.

201 California Street, Suite 1500 San Francisco, CA 94111

FULLY SPRINKLERED

FIRE PROTECTION:

Jensen Hughes 2950 Buskirk Avenue | Suite 225 Walnut Creek, CA 94597

CONSULTANT:

GEOTECHNICAL:

Allegiance Group 4321 SW Corbett #200 Portland, OR 97239

COST ESTIMATING:

AECOM

300 California Street, Suite 400 San Francisco, CA 94104

KEY PLAN

Station Number Project Number

640 640-423

Building Number

U.S. Department of Veterans Affairs

RS

N:

//o ma c-i nr ev itp

/20

-V A/

_L ive rm or e_

Re ali gn me ntA nd

Cl os ur e/A

R/

_B -C

BO

C_

Ce ntr al.

rvt

/16

/20

:39

:37 A

M

A-101-A

LEVEL 1 AREA A- ARCHITECTURAL PLAN

GFD TN03 JULY 2018

VA Livermore Realignment and Closure - Part B - CBOC

Stockton (French Camp) San Joaquin County, CA

800 (CBOC), 803 (CUP)

1/8" = 1'-0"A1 LEVEL 1 AREA A

EXTERIOR KEYNOTES

05-01 STRUCTURAL BRACING VISIBLE THROUGH GLASS

EXTERIOR SYSTEMS LEGEND

CWS-1 MULTI-LEVEL CURTAIN WALL SYSTEM TYPE 1

CWS-2 ALUMINIUM STOREFRONT WALL SYSTEM TYPE 2

MPRS-1 METAL PANEL RAINSCREEN SYSTEM TYPE 1

MPRS-2 METAL PANEL RAINSCREEN SYSTEM TYPE 2

PRPS-1 PHENOLIC RESIN PANEL RAINSCREEN SYSTEM TYPE 1

NO REVISIONS DATE

1 DESIGN CLARIFICATIONS 19 NOV 18

RS:S:S:

UP

E F G H J K L M

7.2

N

6.8

STOR,

BULK

1A106H

SRS01

COFFEE

SHOP

1A131

BX001

HEMATOLOGY

LAB

1A106B

LMCH3

STOR

PHLEBOTOMY

1A106D

SRS04

TLT-URIN

1A106K

TLTU1

MDF RM

1A112

ITNT1

WAIT, LAB

1A106

WRC01

BLOOD

SPECIMEN

COLLECTION

1A106A

LBVP1

PAT TLT

1A107E.1

TLTU1

ULTRASOUND

1A107E

XDUS1

CLEAN

UTIL

1A107M

UCCL1

RADIOLOGY

1A107G

XDR01

RADIOLOGY

1A107H

XDR01

SOILED

UTIL

1A110

USCL1

PAT TLT

1A107C

TLTU1

DRESSING

RM

1A107G.1

DR001

DRESSING

RM

1A107H.3

DR001

OFFICE

1A107H.1

OFDR1

STRETCHER

HOLD

1A107B

SRHM1

SHARED

MED APPT

1A137

CRA03

PATIENT

RESOURCES

1A138A

OFA03

PHARMACY

WAIT

1A105

WRC01

ST TLT

1A106J

TLTU1

DI WATER

1A106F

SRR02

PRIVATE

DRAW

1A106C

LBVP1

DOCUMENT

CONTROL

1A107A.1

MRS01

CORR

C1111

WAIT,

RADIOLOGY

1A107

WRC01

DRESSING

RM

1A107D

DR001

OFF,

SHARED

1A113

OFA03

COMPUTER

REP/ STOR

1A113E

ITWR1

SW RM

1A113B

TEDR1

SUPPLY

STOR

1A113D

SRE01

INTAKE

1A105R

PHOD1

INTAKE

1A105S

PHOD1

ST TOILET

1A105H

TLTU1

RECEIVING

BREAKDWN

1A105G

PHOD2

ST LKRS,

LOUNGE

1A105F

SL001

VAULT,

CONTROLLED

SUBSTANCE

WORK

AREA

1A105N

PHOD2

OFFICE,

SUPV.

1A105K

OFD03

ASEPTIC

(CLEANROOM)

1A105L

PHIV2

ANTE

1A105M

PHIV2

CIRCULATION

1A105C

PHARMACY

WORK

AREA

1A105A

TLT-URIN

1A106L

TLTU1

VEST

1A106M

CORR

C1102

SHARED

MED APPT

1A134

CRA03

VEST

1A107H.2

VEST

1A107G.2

TLT

PUBLIC F

1A102

TLTF2

TLT

PUBLIC M

1A104

TLTM2

INFO/

RECEP

DESK

1A100B

RECP3

WAIT

1A138

WRC01

VEST

1A101

FITTING

AND

DISPENSING

1A138E

EYFD1

SHARED

MED APPT

1A136

CRA03

SHARED

MED APPT

1A135

CRA03

COMMAND

CENTER

STOR

1A134A

SRE01 KITCHENETTE

1A132

LACTATION

1A122

LAC01

TECH

WORKRM

1A107A

CMP01

CONTROL/

TECH

WORKRM

1A107G.4

CMP01

MAMMOGRAPHY

1A107J

XDM01

MAMMO

WAIT

1A107L

WRC01, WRF01

MAMMO

DRESSING

1A107K

DR001

WHEELCHAIR

STOR

1A100D

SRLW1

LOBBY

1A100

ELEV P-1

P-1

ELEV P-2

P-2

ELEV P-3

P-3

STAIR 1

1S001

CORR

C1103

CORR

C1110

ELEC

1A138F

CORR

C1105

ELEC

1A106N

CORR

C1100

L6

A4

A4

L6

M4

C4

M4

A4

A4A4

A4

A4

A4

A4

A4 (S

A4

A4 (S

A8

A4

A4

A4

A4

M4 Z1

A4

A4

A4

A4(S)

A4

R4

L6 L6

A4

A4

A4

A4

A4

A4

C4

A4 (S

C8

A4

A4

A4

A4

A4 (S

A4

B4

A4(S) M4

M4

A8

A4

A4

L4

L6

L6

LL

L6

L6

L4

L6

A8

L6

A4

A4

A4

A4

A4

A4

A4

A4

A4

L4

F6

WAIT

1A138G

WRC01 FEC-1

FEC-1

'-7

7'-

4" 4'-

3"

'-1 1"

A1

A- 1 0

1- A

A1

A-10 1-C

A1

A- 1 0

1- A

/A1 A-101-A /A1 A-101-B

A1

A- 1 0

1- C

MAIN ENTRANCE

A1

A-10 1-B

/A1 A-101-A

F6 F6

M4

M4

M4

M4 A4 (S

M4

A4

M4

A4

M4

A4

L4L4

L6

L4L4

L6

A4

M4

1' - 8" 9"

F.A. CLO.

1A106P

A4

A4 (P

A4

A4 A4

A4

A4

A4

A4

A4 (S

A4

A4

A4(S)

A4(S)

A4

A4

A4WAIT

1A147

WRC01

A4

27'-0" 31'-0" 31'-0" 7'-2" 22'-10" 31'-0" 31'-0" 27'-0" 23'-0"

A4

17'-8"

FEC-1

FEC-1

FEC-1

FEC-1

FEC-1 FEC-1

M4

M4

M4

Z1

C4

L6(S)

L4(S)

L4 (S

CIRCULATION

1A100E

KIOSKS

1A146Y

22'-3" 7"

4'- 5"

'-1

0" 8"

HO

LD

1'- 0"

'-1

'-3

1'- 0 1

/2"

1'- 0"

'-1

'-6

7'-

9'- 3"

'-2

11" 25'-1" 4'-0" 11'-8"

3'-9 1/2" 3'-0"

2'-0"

2'

- 0

2'-0"

2'- 0"

9'-8 1/2" 7'-5" 6'-1" 12'-3 1/2"

1'- 0"

'-5

1'- 0"

1'- 0"

7'

- 1

1" 7'

- 1 0"

7'

- 3

4" 4'-9 1/2"

1'- 0"

5'- 0"

1'-0" 1'-0" 9'-5"

1'- 0"

1'- 0 1

/2"

5'- 9 1

/2"

HOLD

7'-0"

1'- 5"

1'- 5"

1'- 5"

1'- 5"

1'- 5"

1'- 5"

2'-0"

2'- 0"

2'- 0"

1'-7"

2'-0"

2'- 0"

2'-0"

2'- 0"

2'-0"

2'- 0"

2'-0"

2'- 0"

1'-4 1/2" 1'-4 1/2" 1'-4 1/2" 1'-5"

14'-9 1/2"

2'- 0"

1'- 7" 1'-7"

2'-0"

8'-0" 30'-0" 6'-6 1/2" 9'-0"

12'-0 1/2" 8'-5" 8'-10 1/2" 5'-9"

1'- 6"

7'- 5"

8'- 8"

6'- 2 1

/2"

A-406 B8

TYP

A-406 D3

TYP

A-406 A3

TYP

A-401 D3

Sim

A-404 C3

Sim

'-5

7'-

1"

'-7

CL

CL

6'- 9"

1'- 6"6'-9 1/2"

CL

CL

'-6

8'-

8"

9'

- 7

4'

- 6

6'

- 3

CL

CL

5'-10"

4'-

" 7'-6 1/2"

7'-0"

1'-10" CL

1'

- 0

1"

5'-9" 20'-0"

A-407 A1

TYP

CL

CL

1' - 6"

1' - 6"

CL

CL

9'- 5 1

/2" 3'-

6 1 /2"

A-411 E3

Sim

ALIGN

G

A4(S)

A4 (S

A4 (S

H.2

A-406 E3

TYP

25'-4" 13'-9" 20'-1 1/2" 3 1/2" (R.O.)

8'-4" 32'-4"

(R.O.)

4'-1" 22'-9 1/2"

(R.O.)

79'-3 1/2" 26'-0"

1'- 4" 1'

- 3

1/ 2"

1'

- 7

1/ 4"

(R .O

8'

- 5 1/

2" 1'

- 6 1/

4" 1'

- 5 3/

4"

(R .O

4'-

9 3 /4"

R4

R4

R4

R4

1'- 8"

CL

EQ EQ

4'

- 6

1/ 2"

Z1

A4

M4

PICK-UP

1A105T.1

OFDC2

1'

- 6

/16

A4

M41(SS)

A4

A4

R1

R1

1' - 8"

1'

- 7

R4

R4

M4 1(

SS

M41(SS)

M4 1(

SS

A-440 A7

A-450 A7

R4 R4

R4

2'- 5 1

/2"

1'

- 0

9"

B4 R4

R4

R4R4

R4

R4 A4

R4

A4(S)

A4(S)

MI

N.

1'

- 0

MI

N.

1'

- 4

1'

- 0

1'

- 0

PT

2'

- 5

"8' - 10"

PT

9'

- 2

9' - 2"

PT

5'

- 5

3/ 4"

9' - 2 1/2"

PT

5' - 4"

8'

- 1

0"

PT

PT

PT

7'

- 6

5' - 4"

5' - 4"

5' - 4"

9'

- 2

7'

- 4

PT

2' - 2"

5'

- 2

A-407 C3

TYP

A-411 C8

Sim

F4

F4

F4

B4

B4D6

B6

B6

R1

R1

R4

A4

B4 B4B4

B4 B4

B4

B4 B4

6"

6"

4' - 4"

3' - 0"

(R .O

1 1

/4"

'-5

3'

- 0

'-3

1/ 2"

1'-

3/ 4"

A4 (S

A4(S)

C4

C4

A4(S)

1A1121A112

MDF RM

B4 A4

(S

6'

- 0

1'

- 6

MI

N

1'

- 6

AIR PRESSURE

GAUGE MONITOR

URINALYSIS

1A146Z

3'-0"

CLR WIDTH

3'-0"

CLR WIDTH

9'

- 5

7/ 8"

CORR

C1112

2'

- 8

BLOOD

BANK

1A106E

LMBB1

4'- 1"

9'

- 0

4' - 4"

2'- 1 1

/2" 12' - 4"

5'- 9"

9' - 2 7/8" 7' - 0 5/8"6'-0" 9'-6 1/2"6'-0 1/2"9'-9 1/2" 9'-9 1/2"1'-0" 12'-0"

'-1

1 1 /4"

2'

- 1

0" 7'

- 9

M4

M4

A4

PT

0"

8' - 6"

20'-7" 11 1/2"

1'

- 0

7 1/2"

AL

IG

N

3'

- 1

0"

HOLD

7' - 0"15'-0 1/2" 2'-5 1/2"12'-11"

1'-4 1/2" 6'-8 1/2" 3'-10 1/2"6'-5" 7"11'-6" 8'-6" 7" 7'-6"11'-11 1/2" 8'-6 1/2" 4'-2 1/2"4" 9'-2" 13'-0"

7"

A4

6' - 1" 1

NON RATED PARTITION

1 HOUR FIRE BARRIER WALL

2 HOUR FIRE BARRIER WALL

LEAD LINED PARTITION

PARTITION SYMBOLS

REFER PLANS FOR TYPES

AND TO SHEET A-601 FOR INFORMATION

NON RATED SMOKE PARTITION

MODULAR PARTITION (U.N.O.)

CMU + GWB PARTITION

GENERAL NOTES:

1. REFER TO A-100 SERIES DIMENSION SHEETS FOR

OVERALL DIMENSIONS AND PARTITION TYPES

2. REFER TO A-400 SERIES FOR ENLARGED PLANS

3. REFER TO A-03 FOR TYPICAL MOUNTING HEIGHTS AND

ABA REQUIREMENTS

4. REFER TO A-200 SERIES FOR INTERIOR ELEVATIONS

5. REFER TO A-401, A-402 AND A-404 FOR TYPICAL TOILET

ROOM LAYOUTS; REFER TO A-405 FOR TYPICAL AND

REPEATING ROOMS INCLUDING BUT NOT LIMITED TO

CONSULT/ EXAM AND PROCEDURE ROOMS, NOTE THAT

EYE TESTING ANTERIOR, EYE LASER TREATMENT,

PHOTOGRAPHY, SPEECH ANALYSIS, IMMITTANCE, AND

TREAT-OPHTHA ARE TO ALSO REFERENCE THESE

ROOMS FOR TYPICAL LAYOUTS.

6. REFER TO A-700 SERIES FOR RCPS

7. REFER TO A-502 FOR CEILING DETAILS

8. REFER TO A-520 FOR CASEWORK DETAILS

9. REFER TO AI SERIES FOR INTERIOR FINISHES

10. FURNITURE, ACCESSORIES, AND EQUIPMENT SHOWN

FOR REFERENCE ONLY; REFER TO EQ SERIES

DRAWINGS FOR SCHEDULE AND QUANTITIES NOT

SPECIFICALLY SHOWN ON A-100 SERIES PLANS. FOR

LOCATION OF THESE ITEMS REFER TO SHEET A-03 FOR

TYPICAL MOUNTING HEIGHTS AND ABA REQUIREMENTS.

FOR TYPICAL ACCESSORIES REFER TO DETAILS A7 &

C1, U.N.O.

11. REFER TO FJ SERIES, LIFE SAFETY PLANS, FOR

LOCATIONS OF REQUIRED RATED WALLS, SMOKE

PARTITIONS, AND SMOKE BARRIERS, IF CONFLICT

EXISTS USE MOST RESTRICTIVE

12. REFER TO A-603 FOR GENERAL BLOCKING NOTES FOR

TYPICAL METAL STUD BLOCKING AND METAL STUD

FRAMING REQUIRED.

13. REFER TO SHEET QH-A600 FOR SPECIFIC LOGISTICS

CATEGORY OF EQUIPMENT ITEMS, ALL ITEMS ARE TO

BE ASSUMED TO BE C/C UNLESS SPECIFICALLY LISTED

OTHERWISE ON SHEET QH-A600 REGARDLESS OF

GRAPHIC REPRESENTATION.

14. MODULAR PARTITIONS V/V - GOVERNMENT FURNISHED/

GOVERNMENT INSTALLED, REQUIRE COORDINATION

WITH ELECTRICAL, SECURITY, TELECOM, AND

HARDWARE FOR INCORPORATION OF CONDUIT AND TO

SUPPORT WIRING AND DEVICES - TYPICAL.

D

B

C A on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot th re e-ei gh th in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot

6" on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot th re e in ch es o ne fo ot

6"

6"

6"

Drawing number

Drawn

Location

Project Title

Date Checked by

Drawing Title

1 2 3 4 5 6

A

B

C

D

E

F

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

CONSULTANTS: ARCHITECTS/ENGINEERS: Office of Construction and Facilities Management

7 8 9

MECHANICAL/ELECTRICAL/

PLUMBING:

Gayner Engineers 1133 Post Street San Francisco,CA 94109

STRUCTURAL:

Degenkolb Engineers 375 Beale Street Suite 500 San Francisco, CA 94105

CIVIL / SURVEYOR:

Sandis 636 9th Street Oakland, CA 94607

ARCHITECTURE/

INTERIOR DESIGN/

SECURITY/SIGNAGE/

COMMUNICATIONS/ MEDICAL

EQUIPMENT/ MASTER PLAN

LANDSCAPE/

ENVIRONMENTAL

ASSESSMENT:

HDR Architecture, Inc.

201 California Street, Suite 1500 San Francisco, CA 94111

FULLY SPRINKLERED

FIRE PROTECTION:

Jensen Hughes 2950 Buskirk Avenue | Suite 225 Walnut Creek, CA 94597

CONSULTANT:

GEOTECHNICAL:

Allegiance Group 4321 SW Corbett #200 Portland, OR 97239

COST ESTIMATING:

AECOM

300 California Street, Suite 400 San Francisco, CA 94104

KEY PLAN

Station Number Project Number

640 640-423

Building Number

U.S. Department of Veterans Affairs

RS

N:

//o ma c-i nr ev itp

/20

-V A/

_L ive rm or e_

Re ali gn me ntA nd

Cl os ur e/A

R/

_B -C

BO

C_

Ce ntr al.

rvt

/16

/20

:40

:27 A

M

A-101-A-1

LEVEL 1 AREA A - DIMENSION PLAN

Checker HJ03 JULY 2018

VA Livermore Realignment and Closure - Part B - CBOC

Stockton (French Camp) San Joaquin County, CA

800 (CBOC), 803 (CUP)

1/8" = 1'-0"A1 LEVEL 1 AREA A

EXTERIOR KEYNOTES

05-01 STRUCTURAL BRACING VISIBLE THROUGH GLASS

EXTERIOR SYSTEMS LEGEND

CWS-1 MULTI-LEVEL CURTAIN WALL SYSTEM TYPE 1

CWS-2 ALUMINIUM STOREFRONT WALL SYSTEM TYPE 2

MPRS-1 METAL PANEL RAINSCREEN SYSTEM TYPE 1

MPRS-2 METAL PANEL RAINSCREEN SYSTEM TYPE 2

PRPS-1 PHENOLIC RESIN PANEL RAINSCREEN SYSTEM TYPE 1

NO REVISIONS DATE

1 DESIGN CLARIFICATIONS 19 NOV 18

FRAME SUB-TYPES

M MASONRY HEAD

(SEE ADJACENT FRAME SUB-TYPES ELEVATIONS)

R RADIATION RESISTANT

(SEE SPECIFICATIONS)

DOOR PANEL TYPES

NOTES

1. SEE DOOR SCHEDULE FOR DOOR WIDTH AND HEIGHT

2. FRAME TYPE 11M DEPTH/THROAT IS 6" UNLESS OTHERWISE NOTED

FRAME TYPE NOMENCLATURE

X x

DENOTES FRAME SUB-TYPE

DENOTES FRAME TYPE

(SEE ADJACENT FRAME TYPE ELEVATIONS)

1 11M 2 43

SEE SCHEDULE

DOOR WIDTH

SE

E

SC

HE

DU

L E

DO

OR

H

EI

GH

T

A

A

B

A

C1

C

D

A

16 GA. FLAT BACKING

DUAL EGRESS

D

D

SEE SCHEDULE

DOOR WIDTH 1' - 2" 2"

TEMPERED

SIDELITE U.N.O.A

A

1R

SEE SPECIFICATIONS

FOR RADIATION RESISTANT

E C7

A-608 2" 2"

2" EQ

EQ

5/8"1 3/8"

2 5/8"

A CB C1 D

EQ.2"EQ.

5/8

2"

SEE PLANS FOR TYPE

WALL WIDTH

2" 2"

SEE PLANS FOR TYPE

WALL WIDTH

SE

E

PL

AN

S

FO

R

TY

PE

W

AL

L W

ID

TH

SEE PLANS FOR TYPE

WALL WIDTH

SEE PLANS FOR TYPE

WALL WIDTH

2"

4"

E

2" 2"

2"

DOOR SIDE

WINDOW SIDE

1 1/2" 2 1/2"

B

ALUM GLASS

EXTERIOR

4" 2'-

0"

4"

4" 4"

C

ALUM GLASS

INTERIOR

4" 2'-

0"

4"

4" 4"

F

FLUSH DOOR

FG

FULL GLASS DOOR

5'

5"

6" 6"

K

LEAD LINED DOOR

KN

LEAD LINED DOOR

2'- 9"

3'- 6"

1'-0" 6"

N

NARROW LITE DOOR

2'- 9"

3'- 6"

1'-0" 6"

UF

UNBALANCED FLUSH

OG

OVERHEAD

ROLL-UP DOOR

OSG

OVERHEAD SECURITY GRILLE

VF

VERTICALLY FOLDING ROOM DIVIDER

MS4

4 PANEL DOUBLE SLIDE

FULL TRACK

AS4

4 PANEL BI-PARTING

HALF TRACK

BREAK OPEN ANY POSITION

X

X

RECESSED TRACK

MIRRORED GLASS LAMINATED GLASS

LEAD

GLASS

AS

S

CH

ED

UL

ED

AS SCHEDULED AS SCHEDULED

HALF TRACK

MS2

2 PANEL SINGLE SLIDE

HALF TRACK

LAMINATED GLASS

RECESSED DOOR PULL (TYP)

GENERAL NOTES:

1. DOOR AND FRAME ASSEMBLIES SHALL COMPLY WITH ALL GENERAL NOTES &

LEGENDS, DOOR AND FRAME DETAILS, COMPONENTS INDICATED BY THE "DOOR- FRAME

SCHEDULE", AND PROJECT REQUIREMENTS AS SPECIFIED.

2. DOOR TYPE SYMBOL REFERENCE "DOOR TYPE DIAGRAMS", INDICATING LAYOUT OF

THE DOOR ASSEMBLY, LOCATION AND SIZE OF GLASS AND LOUVER PANELS, AND

DIMENSIONS OF RAILS AND STILES.

3. DOOR SWING DIRECTIONS INDICATED ON THE DOOR TYPE DIAGRAMS ARE

DIAGRAMMATIC ONLY, FOR ACTUAL DIRECTION AND HANDEDNESS OF DOOR SWING,

REFER TO FLOOR PLANS.

4. REFER TO DOOR SCHEDULE FOR GLAZING TYPE.

5. GLASS LIGHT DIMENSIONS ARE TO EDGE OF EXPOSED GLASS.

LEVEL 1

0' - 0"

14'-10"

5'

- 4

3'

- 8

" IW01

LAMINATED

GLASS (TYP.)

Sim A5

A-609 Sim A5

A-609

Sim A6

A-609

Sim A5

A-609

3 EQUAL PANELS

LEVEL 1

0' - 0"

4'

- 0

3'

- 0

5' - 0"

IW02

C7 A-608

C7 A-608

LEVEL 1

0' - 0"

4'

- 0

3'

- 0

3' - 0"

IW03

C7 A-608

C7 A-608

LEVEL 1

0' - 0"

4'

- 0

3'

- 0

2' - 0"

IW06

LEAD LINED/

LAMINATED GLASS

Sim C8

A-608

D3 A-608

LEVEL 1

0' - 0"

2'

- 1

0" 4'

- 2

BO

TT

OM

O

F

SI

LL

2'

- 8 1/

4"

4" 4' - 0" 4" 4' - 8"

IW07

7'

- 0

LAMINATED

GLASS

E5 A-609

D5 A-609

E5 A-609

Sim

COILING COUNTER

DOOR ON ROOM

SIDE

LEVEL 1

0' - 0"

3' - 0"

2'

- 6

3'

- 7 1/

4"

IW05

LAMINATED

GLASS

MA

X.

T O

SI

LL

3'

- 8

E1 A-609

D1 A-609

E1 A-609

Sim

LEVEL 1

0' - 0"

4'

- 0

4'

- 4

3' - 0"

IW04

B5 A-609

B1 A-609

PACKAGE TRANSFER

WITH INTERLOCK

(BOTH SIDES)

Sim B6

A-609 B5

A-609

Sim

1'-4 1/4" 1'-1 1/2"

CEILING AS SCHEDULED

4" METAL STUDS, TYP.

FINISHED CEILING

9'-0"

BRACE TO

STRUCTURE

OVERHEAD SECURITY GRILLE

COIL ABOVE CEILING

GRID

WALL AS SCHEDULED,

WRAP GWB UP TO

OVERHEAD DOOR GUIDE

3X3 STL TUBE, ATTACH TO

FLOOR AND OVERHEAD

STRUCT.

OVERHEAD DOOR GUIDES,

CONNECTION PER MANUF.

LEVEL 1

0' - 0"

Sim A6

A-609

Sim A5

A-609

Sim A5

A-609

2'- 0"

7'- 0"

9'- 0"

16'-2"

EQEQ

(CLEAR)

3'-6"EQEQ

DOOR

OPENING

(AS

SCHED.)

IW08

LAMINATED

GLASS (TYP.)

LEVEL 1

0' - 0"

3' - 6" EQ

15' - 6 1/2"

2'

- 0

7'

- 0 "9'

- 0

DOOR

OPENING

(AS

SCHED.)

Sim A6

A-609

Sim A5

A-609

Sim A5

A-609

EQ EQ

(CLEAR)

3' - 6"

IW09

LAMINATED

GLASS (TYP.)

PARTITION AS SCHEDULED

SLIDING DOOR FRAME ASSEMBLY

SHIM AS REQUIRED

SLIDING DOORS

SLIDING DOOR TRACK ASSEMBLY

STUD HEADER AS REQUIRED

DO

OR

O

PE

NI

NG

H

EI

GH

T

P

ER

IM

ET

ER

4" T

YP

FLUSH MOUNTED

MIRRORED GLASS

DOOR OPENING WIDTH

@ PERIMETER

4" TYP

FLUSH MOUNTED MIRRORED GLASS

PARTITION AS SCHEDULED

SLIDING DOOR FRAME ASSEMBLY

SLIDING DOORS IN OPEN

POSITION

SHIM AS REQUIRED

RECESSED DOOR PULL (TYP)

on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot th re e-ei gh th in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot

6" on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot th re e in ch es o ne fo ot

6"

6"

6"

Drawing number

Drawn

Location

Project Title

Date Checked by

Drawing Title

1 2 3 4 5 6

A

B

C

D

E

F

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

CONSULTANTS: ARCHITECTS/ENGINEERS: Office of Construction and Facilities Management

7 8 9

MECHANICAL/ELECTRICAL/

PLUMBING:

Gayner Engineers 1133 Post Street San Francisco,CA 94109

STRUCTURAL:

Degenkolb Engineers 375 Beale Street Suite 500 San Francisco, CA 94105

CIVIL / SURVEYOR:

Sandis 636 9th Street Oakland, CA 94607

ARCHITECTURE/

INTERIOR DESIGN/

SECURITY/SIGNAGE/

COMMUNICATIONS/ MEDICAL

EQUIPMENT/ MASTER PLAN

LANDSCAPE/

ENVIRONMENTAL

ASSESSMENT:

HDR Architecture, Inc.

201 California Street, Suite 1500 San Francisco, CA 94111

FULLY SPRINKLERED

FIRE PROTECTION:

Jensen Hughes 2950 Buskirk Avenue | Suite 225 Walnut Creek, CA 94597

CONSULTANT:

GEOTECHNICAL:

Allegiance Group 4321 SW Corbett #200 Portland, OR 97239

COST ESTIMATING:

AECOM

300 California Street, Suite 400 San Francisco, CA 94104

Station Number Project Number

640 640-423

Building Number

U.S. Department of Veterans Affairs

RS

N:

//o ma c-i nr ev itp

/20

-V A/

_L ive rm or e_

Re ali gn me ntA nd

Cl os ur e/A

R/

_B -C

BO

C_

Ce ntr al.

rvt

/16

/20

:41

:26 A

M

A-607

DOOR AND FRAME TYPES AND DETAILS

Checker Author03 JULY 2018

VA Livermore Realignment and Closure - Part B - CBOC

Stockton (French Camp) San Joaquin County, CA

800 (CBOC), 803 (CUP)

1/4" = 1'-0"

DOOR FRAME TYPE ELEVATIONS

3" = 1'-0"

DOOR FRAME PROFILES

1/4" = 1'-0"

DOOR TYPE ELEVATIONS

1/4" = 1'-0"

IW01

1/4" = 1'-0"

IW02

1/4" = 1'-0"

IW03

1/4" = 1'-0"

IW06

1/4" = 1'-0"

IW07

1/4" = 1'-0"

IW05IW04/IW04A

1/2" = 1'-0"A1 OVERHEAD SECURITY GRILLE HEAD

3" = 1'-0"A3 OVERHEAD SECURITY GRILLE JAMB

1/4" = 1'-0"

IW08

1/4" = 1'-0"

IW09

3" = 1'-0"A5 SLIDING DOOR HEAD (4 PANEL)

3" = 1'-0"A7 SLIDING DOOR JAMB (4 PANEL)

NO REVISIONS DATE

1 DESIGN CLARIFICATIONS 19 NOV 18

3/8"

SEALANT & BACKING ON

BOTH SIDES

W

AL

L A S

SC

HE

DU

LE

D

DOUBLE OR TRIPLE JAMB

STUDS AS SCHEDULED

SHIM AS

REQUIRED

INTERIOR ALUM.

WINDOW SYSTEM

CORNER BEAD

(TYP)

EXTERIOR CURTAIN SYSTEM

SHOWN FOR REFERENCE

ONLY REFER TO EXTERIOR

DETAILS FOR ACTUAL

FRAMING AND ADDITIONAL

INFORMATION.

INTERIOR ALUM.

WINDOW SYSTEM

SHIM AS

REQUIRED

CLEAT

ALIGN

SEALANT & BACKER,

BOTH SIDES.

ANGLE STUD BRACE TO STRUCTURE

ABOVE. BRACE AT EVERY OTHER

SOFFIT STUD. ALTERNATE DIRECTIONS

GLASS AS SCHEDULED

5/8" GWB SOFFIT

SHIM AS REQUIRED

INTERIOR ALUM.

WINDOW SYSTEM

METAL STUD SOFFIT

FRAMING

CONTINUOUS BACKING

CLASS III BULLET

RESISTIVE GLASS

SEALANT, TYP.

METAL SHELF AND DEAL

TRAY

6"

4 1/2" 4 1/2"

3"

2' - 0"

METAL STUDS, SIZE PER SCHEDULE

5/8" GWB EACH SIDE

BALLISTIC MATERIAL -

FULL HEIGHT

4" WIDE BALLISTIC MATERIAL

BATTEN STRIP AT SEAMS OF

SHEETS - PER MANUF. PRINTED

INSTRUCTIONS

9 GA STEEL SECURITY MESH

HORIZ. JOINT REINF. @

16"O.C.

VERTICAL REINFORCING

GROUT SOLID

THREAT SIDESECURE SIDE

METAL STUDS, SIZE PER SCHEDULE

5/8" GWB EACH SIDE

BALLISTIC MATERIAL - FULL HEIGHT

4" WIDE BALLISTIC MATERIAL BATTEN

STRIP AT SEAMS OF SHEETS - PER

MANUF. PRINTED INSTRUCTIONS

9 GA STEEL SECURITY MESH

HORIZ. JOINT REINF. @

16"O.C.

VERTICAL REINFORCING

#__ @ __ IN O.C.

GROUT SOLID

THREAT SIDESECURE SIDE

CLASS III BULLET

RESISTIVE GLASS

OPENING SHOWN

BEYOND AT JAMB FOR

VOICE TRANSMISSION

8" CMU HEAD BOND BEAM

SEALANT

CORNER BEAD

METAL STUDS, SIZE PER SCHEDULE

5/8" GWB EACH SIDE

BALLISTIC MATERIAL - FULL HEIGHT

4" WIDE BALLISTIC MATERIAL BATTEN

STRIP AT SEAMS OF SHEETS - PER

MANUF. PRINTED INSTRUCTIONS

9 GA STEEL SECURITY MESH

HORIZ. JOINT REINF. @

16"O.C.

VERTICAL REINFORCING #__ @

__ IN O.C.

GROUT SOLID

THREAT SIDESECURE SIDE

MOUNTING HOLE

8" CMU HEAD BOND BEAM

SEALANT

DOOR RELEASE

DOOR2"

FIXED FLANGE

ADJUSTABLE

FLANGE

CEILING AS

SCHEDULED

PARTITION

SCHEDULED

6"-18 GA BOX BEAM

HEADER (16GA AT +10'-0"W

OPG'S)

MTL STUD KICKER,

AS REQ'D

CASING BEAD

SHIM AS REQUIRED

SEALANT

MTL STUD

FIN CLG HT

SEE RCP

FIN CLG HT

SEE RCP

OP

EN

IN

G

AS

S

CH

ED

UL

ED

VA

RI

ES

, S

EE

R

CP

CASING BEAD

SEALANT

ALUM SLIDING WINDOW UNIT

WOOD SHIM

3'- 8"

A

FF

, U

NO

CEILING AS SCHEDULED

SECTION AT HEAD

PARTITION

SCHEDULED

6"-18 GA BOX BEAM

HEADER (16GA AT +10'-0"W

OPG'S)

MTL STUD KICKER,

AS REQ'D COORDINATE

WITH COILING DOOR

CASING BEAD

SHIM AS REQUIRED

SEALANT

MTL STUD

OP

EN

IN

G

AS

S

CH

ED

UL

ED

WAITING SIDEROOM SIDE

FIN CLG HT

SEE RCP

COILING COUNTER DOOR

MECHANISM ABOVE

CEILING

COILING COUNTER DOOR

WAITING SIDEROOM SIDE

SOLID SURFACE

COUNTERTOP W/ MDF

SUBSTRATE

1 1 /2"

SEALANT

ALUM SLIDING WINDOW UNIT -

SEE WINDOW SCHEDULE

WOOD SHIM

2'-

" A

FF

, U

NO

8"

COILING COUNTER DOOR

FRAME AT JAMB BEYOND

CASING BEAD

SHIM AS REQUIRED

SEALANT

MTL STUD

ALUM SLIDING DOOR UNIT -

SEE DOOR SCHEDULE FOR

SIZE

AL

UM

S

LID

IN

G

DO

OR

U

NI

T

HE

IG

HT

- S

EE

D

OO

R

SC

HE

D

.1/ 2"

AL

IG

N

ROOM SIDECORRIDOR SIDE

COORD W/ MFR TRACKLESS

THRESHOLD

SCHEDULED FINISH FLOOR

ALUM SLIDING DOOR UNIT -

SEE DOOR SCHEDULE

FIN CLG HT

SEE RCP

FIN CLG HT

SEE RCP

CEILING AS SCHEDULED

SEALANT

AUTOMATED

SLIDING DOOR

ALIGN

FR

AM

E 4 1

/2"

SLIDING DOOR UNIT WIDTH- SEE DOOR SCHEDULE

CASING

BEAD

SHIM AS

REQUIRED

METAL STUD,

DOUBLE @ JAMBS

ROOM SIDE

CORRIDOR SIDE

RE

FE

R

TO

P

LA

N

VA

RI

ES

NOTE:

AT DOOR HEAD FRAMING TO BE

BOX HEADER IN LIEU OF DOUBLE

STUDS EACH SIDE AS SHOWN

ALUMINUM STOREFRONT

CURTAIN WALL SYSTEM

ALUMINUM DOOR

ALUMINUM HORIZONTAL MULLION

7 1/2"

5/8

2 1 /2"

B.O. MULLION

RE: WINDOW

SCHEDULE

ALUMINUM STOREFRONT

CURTAIN WALL SYSTEM

ALUMINUM DOOR

ALUMINUM VERTICAL

MULLION

7 1 /2"

2 1/2" 5/8"

ALUMINUM HORIZONTAL

MULLION BELOW

DOOR FRAME

BEYOND

CONTINUOUS RAIN

SCREEN INSULATION

8" CMU HEAD BOND BEAM

EXTERIOR WALL SYSTEM

MPRS-3

SEALANT - EACH

SIDE & ALL

AROUND, TYP.

DOOR AS SCHEDULED

STAINLESS STEEL DRIP

FLASHING

HOLLOW METAL FRAME

(4" HEAD & 2" JAMB)

AIR AND WEATHER BARRIER

ALUM CLOSURE AT JAMB

LOCATION

BACKER ROD AND SEALANT

FLEXIBLE MEMBRANE OVER

AIR AND WEATHER BARRIER

ON TOP OF METAL FLASHING

SOLID GROUT

1 1/64"

8" M

IN

4 x 8 x 16 CMU

STRUCTURAL SLAB

RE: STRUCT

GROUT SOLID

BRICK LEDGE

CONCRETE FOUNDATION

REINFORCING SEE STRUCT

5" 6 1

/2" 8"

2' - 5 1/2" 6 1/2"

FILL IN MATERIAL

2'

- 0

3' - 0"

DOOR AS SCHEDULED

PAVING SLOPE TO DRAIN,

RE: CIVIL

THRESHOLD AT DOOR SET IN

SEALANT

WATERPROOFING MEMBRANE

1"1" 1" MIN

WATERPROOFING

MEMBRANE

/12

8" M

AX

VAPOR BARRIER

UNDER SLAB, TYPICAL

CONTINUOUS RAIN

SCREEN INSULATION

8" CMU HEAD BOND BEAM

EXTERIOR WALL SYSTEM

MPRS-3

CONTINUOUS STEEL ANGLE

BETWEEN HSS COLUMNS

LOUVER SUPPORT PER STRUCT

STAINLESS STEEL DRIP

FLASHING

REMOVABLE BLAST LOUVER

AIR AND WEATHER BARRIER

ALUM CLOSURE AT JAMB

LOCATION

BACKER ROD AND SEALANT

FLEXIBLE MEMBRANE OVER

AIR AND WEATHER BARRIER

ON TOP OF METAL FLASHING

LOUVER FASTENERS PER

LOUVER MANUFACTURER, TYP.

EXPANSION

ANCHOR PER

STRUCT

8"

REMOVABLE MISC.

STEEL HSS COLUMNS

LOUVER SUPPORT

PER STRUCT

STEEL CLIP

ANGLES CONNECT

TO HSS COLUMNS

LOUVER SUPPORT

PER STRUCT

1"

7 5/8" 6 81/128"

6" 1" 6"

METAL SILL FLASHING WITH

BACK AND END DAMS ON

BED OF SEALANT OVER

WATERPROOFING MEMBRANE

REMOVABLE BLAST LOUVER

LOUVER FASTENERS PER

LOUVER MANUFACTURER, TYP.

STRUCTURAL SLAB

RE: STRUCT

FILL IN MATERIAL

PAVING, RE: CIVIL

1" 2"

CONTINUOUS STEEL ANGLE

BETWEEN HSS COLUMNS

LOUVER SUPPORT PER STRUCT

EXPANSION ANCHOR

PER STRUCT

REMOVABLE MISC.

STEEL HSS LOUVER

SUPPORT PER STRUCT

STEEL CLIP ANGLES WELD

TO ANGLE CONNECT TO

HSS COLUMNS LOUVER

SUPPORT PER STRUCT

4" CMU

GROUT SOLID

WATERPROOFING

MEMBRANE

6" 125/128" 6"

METAL FLASHING WITH

BACK AND END DAMS

ON BED OF SEALANT

REMOVABLE BLAST

LOUVER

LOUVER FASTENERS

PER LOUVER

MANUFACTURER, TYP.

CONTINUOUS STEEL

ANGLE BETWEEN HSS

COLUMNS WELD TO

HORIZONTAL HSS

REMOVABLE MISC.

STEEL HSS COLUMNS

LOUVER SUPPORT

PER STRUCT

STEEL CLIP ANGLES WELD

TO HORIZONTAL HSS

LO

U

VE

R

P

AN

EL

1"

LO

U

VE

R

P

AN

EL

STEEL CLIP ANGLE WELD

TO HORIZONTAL HSS (TOP

AND BOTTOM) CONNECT

TO HSS COLUMNS BEYOND

CONTINUOUS HORIZONTAL

STEEL HSS BETWEEN HSS

COLUMNS

7' - 11 1/2"

BOTTOM OF HSS

REMOVABLE BLAST

LOUVER

6" 125/128" 6"

LOUVER FASTENERS

PER LOUVER

MANUFACTURER, TYP.

127/128"

DRIP EDGE WITH

SEALANT

on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot th re e-ei gh th in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot

6" on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot th re e in ch es o ne fo ot

6"

6"

6"

Drawing number

Drawn

Location

Project Title

Date Checked by

Drawing Title

1 2 3 4 5 6

A

B

C

D

E

F

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

CONSULTANTS: ARCHITECTS/ENGINEERS: Office of Construction and Facilities Management

7 8 9

MECHANICAL/ELECTRICAL/

PLUMBING:

Gayner Engineers 1133 Post Street San Francisco,CA 94109

STRUCTURAL:

Degenkolb Engineers 375 Beale Street Suite 500 San Francisco, CA 94105

CIVIL / SURVEYOR:

Sandis 636 9th Street Oakland, CA 94607

ARCHITECTURE/

INTERIOR DESIGN/

SECURITY/SIGNAGE/

COMMUNICATIONS/ MEDICAL

EQUIPMENT/ MASTER PLAN

LANDSCAPE/

ENVIRONMENTAL

ASSESSMENT:

HDR Architecture, Inc.

201 California Street, Suite 1500 San Francisco, CA 94111

FULLY SPRINKLERED

FIRE PROTECTION:

Jensen Hughes 2950 Buskirk Avenue | Suite 225 Walnut Creek, CA 94597

CONSULTANT:

GEOTECHNICAL:

Allegiance Group 4321 SW Corbett #200 Portland, OR 97239

COST ESTIMATING:

AECOM

300 California Street, Suite 400 San Francisco, CA 94104

Station Number Project Number

640 640-423

Building Number

U.S. Department of Veterans Affairs

RS

N:

//o ma c-i nr ev itp

/20

-V A/

_L ive rm or e_

Re ali gn me ntA nd

Cl os ur e/A

R/

_B -C

BO

C_

Ce ntr al.

rvt

/16

/20

:42

:35 A

M

A-609

DOOR AND FRAME DETAILS

Checker Author03 JULY 2018

VA Livermore Realignment and Closure - Part B - CBOC

Stockton (French Camp) San Joaquin County, CA

800 (CBOC), 803 (CUP)

3" = 1'-0"A5 JAMB DTL @ INT ALUM STOREFRONT (SILL SIM.)

3" = 1'-0"A3 JAMB DTL @ INT ALUM STOREFRONT

3" = 1'-0"A6 HEAD DTL @ INT ALUM STOREFRONT

3" = 1'-0"B1 SILL DETAIL AT PHARMACY SERVER WINDOW

3" = 1'-0"B5 HEAD DETAIL AT PHARMACY SERVER WINDOW

3" = 1'-0"B6 HEAD DETAIL AT PHARMACY PASS THROUGH WINDOW

3" = 1'-0"E1 SLIDING TRANSACTION WINDOW HEAD

3" = 1'-0"D1 SLIDING TRANSACTION WINDOW SILL

3" = 1'-0"E5 HEAD DETAIL-SLIDING TRANSACTION WINDOW WITH COUNTER

3" = 1'-0"D5 SILL DETAIL- SLIDING TRANSACTION WINDOW WITH COUNTER

3" = 1'-0"D8 HEAD/SILL DETAIL AT MANUAL SLIDING DOOR

3" = 1'-0"B8 MANUAL SLIDING DOOR JAMB (HEAD SIM.)

3" = 1'-0"E7 HEAD DETAIL AT EXTERIOR STOREFRONT

3" = 1'-0"D7 JAMB DETAIL AT EXTERIOR STOREFRONT

3" = 1'-0"E3 DOOR HEAD / JAMB SIM - CUP

1" = 1'-0"D3 DOOR SILL - CUP

3" = 1'-0"C4 LOUVER HEAD / JAMB SIM - CUP

3" = 1'-0"A4 LOUVER SILL - CUP

3" = 1'-0"A8 LOUVER AT STEEL BEAM SUPPORT - CUP

NO REVISIONS DATE

1 DESIGN CLARIFICATIONS 19 NOV 18

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PBPBPBPBPBPBPB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PBPB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PBPB

PB

PB

PB

PB PB

PB

PB

PBPB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PBPBPBPB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

#10

PB

PB

S3AS3AS3AS3AS3AS3AS3A

S3A

S3AS3AS3A

S3

S3

S3

S3

S3

S3

S3

S3

S3 S3

S3 S3

S3

S1A S1A

S3

S1A

S1A

S1A S1A

S3

S3

S3

S3

S3

S3

S3

S3

S1

S1

S1

S1

S3

S3 S3

S3

S3

S1

S3

S3

S2A

S2A

S2A

S2A

S1

S3

S1

S1

S1

S4

S4

S4

S4

S4

S4

S4 S4

S4

S4

S4

S4

S4

S4S4S4S4

S1

S1

S1 S1

S1

S1A

S2A

S2A

S2A

S2A

S2A

S2A

S2A

S2A

S2A

S2A S3

S3 S2A

S2AS2A

S1A S1A

S1A

S2S2S1

S1AS1A

S1

S1

PB

S1

PB

PB

800-HS1WB - 1,3

803-HS1A - 1,3

803-HN1A - 4,6

800-HS1WA - 5,7 800-HS1WA - 1,3

800-HN1EA -

2,4,12

800-HN1EA - 6,8

800-HN1WB - 2,4

#10

#10

#10

#10 #10

#10

#10

#10

#10

#10

#10

#10 #10

PB

PB

PB

PB

PB

S3

S3

S5

S5

S5

S5

S5

S5

S5

S5

S5

#10

#10

2 2 4 4

3 1

7 5

7 5

7 4

31313

S1

800-HN1EA -

10,14

800-HS1WB - 7,9

#10

#10

#10

#10

S4

PB

PBS4

S4

S4

S4

FUTURE

NEIGHBERHOOD B

(PART A)

BLDG 801B

FUTURE

NEIGHBERHOOD A

(PART A)

BLDG 801A

CBOC

(PART B)

BLDG 800

CENTRAL

UTILITY

PLANT

(PART B)

BLDG 803

FUTURE

NEIGHBARHOOD C

(PART A)

BLDG 801C

FUTURE

CLC

(PART A)

BLDG 801

MANTHEY ROAD

MAIN

ENTRY

DRIVE

MANTHEY ROAD

M A

N T H

E Y

R O

A D

M A

N T H

E Y

R O

A D

FUTURE

EXPANSION

IN

T

E R

S T

A T

E R

O U

T E

DRY

DETENTION

BASIN

DRY

DETENTION

BASIN

E

AST-W

EST D

R

IVE

L O

O P

R O

A D

FUTURE

ELB

(PART D)

BLDG 802

PB

PB

S2A

S2A

S7

S7

S7

6 6

VIA 800-LCP1A -

4,5

VIA 800-LCP1A -

1,2

VIA 800-LCP1WA -

1,2

VIA 800-LCP1EA -

1,2,6

VIA 800-LCP1EA - 5,7

VIA 800-LCP1EA -

3,4

VIA 800-LCP1WA

- 3,4

VIA 800-LCP1WB -

1,2

VIA 800-LCP1WB -

3,4

VIA 800-LCP1WB -

5,6

S4

7777777

1133 POST STREET

SAN FRANCISCO, CA 94109

TELEPHONE (415) 474-9500

FAX (415) 474-1363

GAYNER

ENGINEERS

R

EG

IS

TE

RE

D

PROFESSIONAL

ENG

IN

EER

STATE OF CAL IFORNIA

EL EC T R ICA L

BE

NSON NGO

Exp.

E 16075 12-31-19

TRUE

NORTH

0 25'-0" 50'-0" 100'-0" o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

Drawing number

Drawn

Location

Project Title

Date Checked by

Drawing Title

1 2 3 4 5 6

A

B

C

D

E

F

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

CONSULTANTS: ARCHITECTS/ENGINEERS: Office of Construction and Facilities Management

7 8 9

MECHANICAL/ELECTRICAL/

PLUMBING:

Gayner Engineers 1133 Post Street San Francisco,CA 94109

STRUCTURAL:

Degenkolb Engineers 375 Beale Street Suite, Suite 500 San Francisco,CA 94105

CIVIL / SURVEYOR:

Sandis 636 9th Street Oakland, CA 94607

ARCHITECTURE/

INTERIOR DESIGN/

SECURITY/SIGNAGE/

COMMUNICATIONS/ MEDICAL

EQUIPMENT/ MASTER PLAN

LANDSCAPE/

ENVIRONMENTAL

ASSESSMENT:

HDR Architecture, Inc.

201 California Street, Suite 900 San Francisco, CA 94105

FULLY SPRINKLERED

FIRE PROTECTION:

Jensen Hughestion 2950 Buskirk Avenue | Suite 225 Walnut Creek, CA 94597

CONSULTANT:

GEOTECHNICAL:

Allegiance Group 4321 SW Corbett #200 Portland, OR 97239

COST ESTIMATING:

AECOM

300 California Street, Suite 400 San Francisco, CA 94104

Station Number Project Number

640 640-423

Building Number

U.S. Department of Veterans Affairs

11/15/2018 3:23:20 PM E:\Project\10002-01 VAPA Part B\195116-E-B_CBOC_v2015_HW.rvt

ES102

SITE PLAN - LIGHTING

HW CZ/JHE03 JULY 2018

VA Livermore Realignment and Closure - Part B - CBOC

Stockton (French Camp) San Joaquin County, CA

800 (CBOC), 803 (CUP)

SHEET NOTES:

CONNECT TO FLAG POLE LIGHTS

INTERNALLY ILLUMINATED SIGN

RUN #10 CONDUCTOR IN 1 1/4" CONDUIT

FROM PULLBOX TO PULLBOX.

RUN #10 CONDUCTOR IN 3/4" CONDUIT

FROM PULLBOX TO LIGHT FIXTURE.

RUN #10 CONDUCTOR IN 3/4" CONDUIT

FROM PULLBOX TO BOLLARD.

SECURITY CAMERA MOUNTED ON POLE.

SEE ES103 FOR BRANCH CIRCUIT

INFORMATION. PROVIDE POLE WITH

CAMERA MOUNTING PROVISIONS.

FIXTURE TYPE S3A TO BE MOUNTED

SOUTH OF RETAINING WALL.

1" = 50'-0"

SITE LIGHTING

3 TYP.

4TYP.

GENERAL NOTES:

SEE DRAWING E-501 LIGHT BASE AND

BOLLARD BASE DETAILS.

COORDINATE THE LOCATION OF ALL

UNDERGROUND ELECTRICAL WORK

WITH ALL UTILITIES. REFER TO CIVIL

DRAWING FOR GENERAL ROUTING AND

RELATIVE STACKING ARRANGEMENTS

OF ALL SITE UTILITIES.

POLES WITH SECURITY CAMERA

MOUNTING PROVISIONS: OBTAIN

CAMERA MOUNT TEMPLATE FROM

SECURITY CONTRACTOR AND FURNISH

THE MOUNTING TEMPLATE TO POLE

MANUFACTURER PRIOR TO POLE

FABRICATION.

1.

2.

3.

TYPICAL

AM-0003

NO REVISIONS DATE

1 DESIGN CLARIFICATIONS 19 NOV 18

POLE BASE DETAIL - PAVED AREAS

NTS

LIGHT POLE PER LIGHT

FIXTURE SCHEDULE

76x127mm (3"x5")

REINFORCED HAND HOLE WITH

TAMPER RESISTANT SCREWS.

PROVIDE IN-LINE SCREW-TYPE

FUSE HOLDER(S) WITH FUSE(S).

POLE GROUNDING STUD

2-PIECE BOLT COVER PLATE.

PVC CONDUIT ADAPTER

COUPLING

PVC CONDUIT

25mm (1") EMPTY

CONDUIT WITH CAP

(WHERE SHOWN ON

PLANS)

FINISHED PAVING

ANCHOR BOLTS PER POLE

MANUFACTURER'S

REQUIREMENTS WITH LEVELING

NUTS ABOVE & BELOW BASE

PLATE PER MANUFACTURER

m m

3"

0m m M

IN

(2 '-0

#4 BARE COPPER GROUND

6096mm (20'-0") COILED

BELOW BASE

CONCRETE BASE

& REINFORCING STEEL,

SEE NOTE BELOW.

GENERAL NOTES:

1. BACKFILL, CONCRETE, REINFORCING STEEL, AND ANCHOR BOLTS ARE

SHOWN FOR REFERENCE ONLY. STRUCTURAL DESIGN IS SHOWN ON

STRUCTURAL DRAWINGS.

2. REFER TO SPECIFICATION SECTION 26 56 00 FOR MOUNTING AND

LEVELING REQUIREMENTS.

3. REFER TO LANDSCAPE DETAILS FOR INSTALLATION OF PAVERS AND

INTERFACE BETWEEN PAVERS AND POLE BASE.

POLE BASE DETAIL - PLANTING AREAS

NTS

LIGHT POLE PER LIGHT

FIXTURE SCHEDULE

76x127mm (3"x5")

REINFORCED HAND HOLE WITH

TAMPER RESISTANT SCREWS.

PROVIDE IN-LINE SCREW-TYPE

FUSE HOLDER(S) WITH FUSE(S).

POLE GROUNDING STUD

2-PIECE BOLT COVER PLATE.

PVC CONDUIT ADAPTER

COUPLING

PVC CONDUIT25.4mm (1") EMPTY

CONDUIT WITH CAP

(WHERE SHOWN ON

PLANS)

FINISHED GRADE

ANCHOR BOLTS PER POLE

MANUFACTURER'S

REQUIREMENTS WITH LEVELING

NUTS ABOVE & BELOW BASE

PLATE PER MANUFACTURER

m m

(3

0m m M

IN

(2 '-0

#4 BARE COPPER

GROUND 6069mm (20'-0")

COILED BELOW BASE

CONCRETE BASE

& REINFORCING STEEL,

SEE NOTE BELOW

GENERAL NOTES:

1. BACKFILL, CONCRETE, REINFORCING STEEL, AND ANCHOR BOLTS ARE

SHOWN FOR REFERENCE ONLY. STRUCTURAL DESIGN IS SHOWN ON

STRUCTURAL DRAWINGS.

2. REFER TO SPECIFICATIONS SECTION 26 56 00 FOR MOUNTING AND

LEVELING REQUIREMENTS.

BOLLARD BASE DETAIL - PAVED AREAS

NTS

GENERAL NOTES:

1. BACKFILL, CONCRETE, REINFORCING STEEL, AND ANCHOR BOLTS ARE

SHOWN FOR REFERENCE ONLY. STRUCTURAL DESIGN IS SHOWN ON

STRUCTURAL DRAWINGS.

2. REFER TO SPECIFICATION SECTION 26 56 00 FOR MOUNTING AND

LEVELING REQUIREMENTS.

3. REFER TO LANDSCAPE DETAILS FOR INSTALLATION OF PAVERS AND

INTERFACE BETWEEN PAVERS AND POLE BASE.

18"Ø

5'-0"

18"Ø

5'-0"

5-#5 VERT BARS &

#3 SPIRAL WITH 8" PITCH

5-#5 VERT BARS &

#3 SPIRAL WITH 8" PITCH

BOND TO REBAR

RIGID STEEL CONDUIT

UNDISTURBED SOIL

OR SELECT BACKFILL

COMPACTED, SEE

NOTE BELOW.

RIGID STEEL CONDUIT

UNDISTURBED SOIL

OR SELECT BACKFILL

COMPACTED, SEE

NOTE BELOW.

BOND TO REBAR

VANDAL RESISTANT LIGHT

BOLLARD PER LIGHT FIXTURE

SCHEDULE.

PVC CONDUIT ADAPTER

COUPLING

PVC CONDUIT

RIGID STEEL CONDUIT

FINISHED PAVING

GALVANIZED ANCHOR BOLTS &

HEX NUTS. PROVIDE

LEVELING SHIMS OR HEX NUTS

PER MANUFACTURER

m m

(4

0m m M

IN

(2 '-0

UNDISTURBED SOIL

OR SELECT BACKFILL

COMPACTED, SEE

NOTE BELOW

CONCRETE BASE

& REINFORCING STEEL,

SEE NOTE BELOW

3'-0"

18"Ø

5-#5 VERT BARS &

#3 SPIRAL WITH 8" PITCH

GROUNDING STUD

#4 BARE COPPER

GROUND 6069mm (20'-0")

COILED BELOW BASE

BOND TO REBAR

BOLLARD BASE DETAIL - TURF AREAS

NTS

VANDAL RESISTANT LIGHT

BOLLARD PER LIGHT FIXTURE

SCHEDULE.

PVC CONDUIT ADAPTER

COUPLING

PVC CONDUIT

RIGID STEEL CONDUIT

FINISHED GRADE

GALVANIZED ANCHOR BOLTS &

HEX NUTS. PROVIDE

LEVELING SHIMS OR HEX NUTS

PER MANUFACTURER.

m m

(3

0m m M

IN

(2 '-0

UNDISTURBED SOIL

OR SELECT

BACKFILL

COMPACTED, SEE

NOTE BELOW.

CONCRETE BASE

& REINFORCING

STEEL, SEE NOTE BELOW.

GENERAL NOTES:

1. BACKFILL, CONCRETE, REINFORCING STEEL, AND ANCHOR BOLTS ARE

SHOWN FOR REFERENCE ONLY. STRUCTURAL DESIGN IS SHOWN ON

STRUCTURAL DRAWINGS.

2. REFER TO SPECIFICATION SECTION 26 56 00 FOR MOUNTING AND

LEVELING REQUIREMENTS.

18"Ø

3'-0"

5-#5 VERT BARS &

#3 SPIRAL WITH 8" PITCH

#4 BARE COPPER

GROUND 6069mm (20'-0")

COILED BELOW BASE

BOND TO REBAR

GROUNDING STUD

3. WHERE POLE FOUNDATION OVERLAPS WITH ADJACENT FOUNDATIONS

INTEGRATE REINFORCING OF BOTH FOUNDATIONS.

DOWNLIGHT MOUNTING - LAY-IN CEILING

NTS

CEILING HANGER

WIRE, TYP.

RECESSED

CAN LUMINAIRE

ARCHITECTURAL

CEILING GRID

WIRE TIE OR

SCREW BAR

HANGER TO

ARCHITECTURAL

CEILING GRID TYP.

LUMINAIRE

BAR HANGERS

LUMINAIRE SUSPENSION WIRE

REFER TO SPECIFICATION

SECTION 26 51 00.

ACOUSTICAL CEILING

TILE (TYP)

RECESSED CAN

LUMINAIRE

ARCHITECUTRAL CEILING GRID

FIXTURE WHIP FROM

JUNCTION BOX

(1829mm (6') LONG MAX)

GENERAL NOTE:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING

INSTRUCTIONS AND USING RECOMMENDED MOUNTING HARDWARE

EXIT SIGN MOUNTING - GYPBOARD CEILING

NTS

CEILING HANGER WIRE

DRYWALL

CEILING CROSS

TEE, TYP.

CEILING MAIN

BEAM.

DRYWALL CEILING

CROSS TEE, TYP.

GYPSUM

BOARD

WIRE TIE THROUGH

MOUNTING CHANNEL

& CROSS BEAM, TYP.

HANGER WIRE AND MOUNTING CHANNEL

ATTACHED TO STRUCTURE REFER TO

SPECIFICATION SECTION 26 51 00

INTEGRAL GALVANIZED LIPPED

STEEL MOUNTING CHANNEL

JUNCTION BOX

LOCKING SQUARE

WASHER & NUT

6.35mm (1/4") SCREW

FIXTURE WHIP FROM JUNCTION

BOX (1829mm (6') LONG MAX)

GENERAL NOTE:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING

INSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE.

EXIT SIGN MOUNTING - LAY-IN CEILING

NTS

CEILING HANGER WIRE

ARCHITECTURAL

CEILING GRID

ARCHITECTURAL

CEILING GRID

ACOUSTICAL

CEILING TILE (TYP)

HANGER WIRE AND MOUNTING CHANNEL

ATTACHED TO STRUCTURE REFER TO

SPECIFICATION SECTION 26 51 00

INTEGRAL GALVANIZED LIPPED

STEEL MOUNTING CHANNEL

JUNCTION BOX

LOCKING SQUARE

WASHER & NUT

6.35mm (1/4") SCREW

ARCHITECTURAL

CEILING GRID

WIRE TIE THROUGH

MOUNTING CHANNEL

& CROSS BEAM, TYP.

FIXTURE WHIP FROM JUNCTION

BOX (1829mm (6') LONG MAX)

GENERAL NOTE:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING

INSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE.

LUMINAIRE MOUNTING - GYPBOARD CEILING

NTS

LUMINAIRE

SUSPENSION WIRES

REFER TO

SPECIFICATION

SECTION 26 51 00

3 TWIST

MINIMUM (TYP)

FIXTURE WHIP FROM JUNCTION

BOX (1829mm (6') LONG MAX.)

CEILING MAIN BEAM

GYPSUM BOARD

(TYP)

LUMINAIRE.

REFER TO

SCHEDULE

LUMINAIRE MANUFACTURER'S

MOUNTING HARDWARE

REFER TO SPECIFICATION

SECTION…

This is the start of the file's text. The full file is on GovTribe.