FY 11 General Instruction Building (GIB) Presidio of Monterey 1624

Repair or reject defective or inaccurate work.

2.3.3 Counter and Vanity Top Splashes

Backsplashes and end splashes shall be fabricated from 1/2 inch thick solid surfacing material and shall be provided to dimensions and shapes as indicated on the drawings. Backsplashes and end splashes shall be provided for all counter tops and vanity tops. Backsplashes shall be shop fabricated and be permanently attached.

2.3.3.1 Permanently Attached Backsplash

Permanently attached backsplashes shall be attached with seam adhesive and to form a radiused coved transition from countertop to backsplash.

2.3.3.2 End Splashes

End splashes shall be provided loose for installation at the jobsite after horizontal surfaces to which they are to be attached have been installed.

2.3.4 Counter and Vanity Tops

All solid surfacing, solid polymer counter top and vanity top components shall be fabricated from 1/2 inch thick material. Edge details, dimensions, locations, and quantities shall be as indicated on the Drawings. Counter tops shall be complete with 4 inch high permanently attached with coved transition backsplash and loose endsplashes at all locations. Attach 2 inch wide reinforcing strip of polymer material under each horizontal counter top seam.

2.3.4.1 Counter Top With Sink

A. Stainless Steel or Vitreous China Sink.

Countertops with sinks shall include cutouts to template as furnished by the sink manufacturer. Manufacturer's standard sink mounting hardware for rimless installation shall be provided. Seam between sink and counter top shall be sealed with silicone sealant. Sink, faucet, and plumbing requirements shall be in accordance with Section 22 00 00 PLUMBING,GENERAL

PURPOSE.

2.3.4.2 Vanity Tops With Bowls

A. Vitreous China Bowl

Countertops with vitreous china bowls shall include cutouts to template as furnished by the sink manufacturer. Manufacturer's standard sink mounting hardware for vitreous china rimless installation shall be provided. Seam between sink and counter top shall be sealed with silicone sealant. Sink, faucet, and plumbing requirements shall be in accordance with Section 22

00 00 PLUMBING,GENERAL PURPOSE.

2.3.5 Shower Benches

Shower benches shall be fabricated from 1-3/8 inch thick solid surfacing, solid polymer material. Dimensions, edge shape, and other details shall conform to manufacturer's standard product and as indicated on the drawings.

PART 3 EXECUTION

3.1 COORDINATION

In most instances, installation of solid polymer fabricated components and assemblies will require strong, correctly located structural support provided by other trades. To provide a stable, sound, secure installation, 06 61 16- 9 AM-06 to overall width of door frame. Align bottom with door frame rabbet.

2.3.19 Special Tools

Provide special tools, such as spanner and socket wrenches and dogging keys, required to service and adjust hardware items.

2.4 FASTENERS

Provide fasteners of proper type, quality, size, quantity, and finish with hardware. Provide stainless steel or nonferrous metal fasteners that are exposed to weather. Provide fasteners of type necessary to accomplish a permanent installation.

2.5 FINISHES

BHMA A156.18. Provide hardware in BHMA 630 finish (satin stainless steel), unless specified otherwise. Provide items not manufactured in stainless steel in BHMA 626 finish (satin chromium plated) over brass or bronze, except aluminum paint finish for surface door closers, and except BHMA 652 finish (satin chromium plated) for steel hinges. Provide hinges for exterior doors in stainless steel with BHMA 630 finish or chromium plated brass or bronze with BHMA 626 finish. Furnish exit devices in BHMA 626 finish in lieu of BHMA 630 finish . Match exposed parts of concealed closers to lock and door trim. Match hardware finish for aluminum doors to the doors.

2.6 KEY CABINET AND CONTROL SYSTEM

BHMA A156.5, Type required to yield a capacity (number of hooks) 50 percent greater than the number of key changes used for door locks.

2.7 Entry Control Devices

Contractor shall coordinate door hardware installation with electrical drawing T-604, detail A, and also with the Entry Control System specified in specification section 28 20 01.00 10 ENTRY CONTROL SYSTEM, for the following doors: Entry Door 101, 102, 104,105 110, 112 and Stairwell Door 103, and Stairwell Door 113 111. Contractor shall submit shop drawings to obtain approval from Contracting Officer for a complete and useable system that complies with all life safety codes.

2.7.1 Electromagnetic Locks

Electromagnetic locks shall be as specified in specification section 28 20

01.00 10 ENTRY CONTROL SYSTEM. Electromagnetic locks shall be fail safe (unlocked when power is off) and shall conform to BHMA ANSI/BHMA A156.23.

Electromagnetic locks shall comply with life safety requirements of NFPA 101.

2.7.2 Electric Request-To-Exit (REX) Devices

Electric Request-To-Exit (REX) Devices shall be as specified in specification section 28 20 01.00 10 ENTRY CONTROL SYSTEM. An Electric exit device shall be provided at the following door location:

Entry Door 101, 102, 104, 105 110, 112 and 113 Stairwell Door 103, and Stairwell Door

111. Electric exit device shall conform to BHMA ANSI/BHMA A156.3. Exit devices shall comply with life safety requirements of NFPA 101.

08 71 00- 9 AM-06

L2EDMGH9

Cross-Out

L2EDMGH9

Cross-Out

L2EDMGH9

Cross-Out

L2EDMGH9

Cross-Out

L2EDMGH9

Cross-Out

FINISH FINISH DESCRIPTION BASE METAL

600 PRIMED FOR PAINTING STEEL

619 SATIN NICKEL BRASS/BRONZE

630 STAINLESS STEEL

646 SATIN NICKEL STEEL

715 PRIMED FOR PAINTING ALUMINUM

719 MILL FINISH UNCOATED ALUMINUM

HW-1

ALL EXTERIOR STOREFRONT AND EXIT METAL DOOR HARDWARE SHALL BE PROVIDED BY

DOOR MANUFACTURER. (SHALL INCLUDE AS MINIMUM: PIVOTS, HINGES, CLOSERS,

EXIT DEVICES, LOCKSETS, CYLINDERS,ETC.)ALL HARDWARE SHALL COMPLY WITH UFC

(UNITED FACILITIES CRITERIA)DoD MINIMUM ANTITERRORISM STANDARDS FOR

BUILDINGS, BLAST PROTECTION (LOW LEVEL OF PROTECTION).

1 EA. METAL THRESHOLD 719

1 EA. DOOR STOP,L02161(DOME TYPE) 646

1 EA. RAIN DRIP; R0Y973 (TOP), (APPLIES TO METAL DOORS ONLY)

1 EA. ADJUSTABLE ASTRAGAL; R0Y835 (APPLIES TO METAL DOORS ONLY)

1 SET WEATHERSTRIPPING (APPLIES TO METAL DOORS ONLY)

1 EA DOOR SWEEP; ROY536 (APPIES TO METAL DOORS ONLY)

NOTE: DOORS SHALL HAVE THE FOLLOWING INSTALLED TO COMPLY WITH ALL LIFE

SAFETY CODES: ELECTROMAGNETIC LOCKS AND ELECTRIC REQUEST-TO-EXIT (REX)

DEVICES AND ALL REQUIRED ASSOCIATED ENTRY CONTROL SYSTEM EQUIPMENT FOR A

COMPLETE AND USEABLE SYSTEM - SEE ELECTRICAL PLAN T-604, DETAIL A, AND

SPECIFICATION SECTION 28 20 01.00 10 ENTRY CONTROL SYSTEM. VERIFY WITH

CONTRACTING OFFICER.

HW-2

6 EA. HINGES, A5111 (4-1/2" X 4-1/2") 630

2 EA. CLOSER, C02021

(PARALLEL ARM)(PAINT TO 600

MATCH ADJACENT DOOR FRAME)

2 EA. LEVER EXTENSION FLUSH BOLTS, L04081 646

(ONE AT TOP AND ONE AT BOTTOM OF

INACTIVE LEAF)

1 EA. LOCKSET, F04 646

4 EA. SILENCERS, RUBBER

1 EA. SWEEP SEAL

1 EA. METAL THRESHOLD 719

1 EA. METAL ASTRAGAL 600

(PAINT TO MATCH ADJACENT DOOR FRAME)

HW-3

SECTION 08 71 00 Page 13 AM-06

HW-16

6 EA. HINGES,A5111 (4-1/2" X 4-1/2") 630

2 EA. CLOSER, C02021

(PARALLEL ARM) (PAINT TO

MATCH ADJACENT DOOR FRAME) 600

2 EA. EXIT DEVICE, TYPE 08, FUNCTION 08 646

(LOCKSETS PROVIDED BY EXIT DEVICE MFR.)

2 EA. LOCKSET, F04 646

3 EA. SILENCERS, RUBBER

1 EA. METAL THRESHOLD (FIRE RATED)

2 EA. MAGNETIC HOLD OPENS

NOTE: DOORS SHALL HAVE THE FOLLOWING INSTALLED TO COMPLY WITH ALL LIFE

SAFETY CODES: ELECTROMAGNETIC LOCKS AND ELECTRIC REQUEST-TO-EXIT (REX)

DEVICES AND ALL REQUIRED ASSOCIATED ENTRY CONTROL SYSTEM EQUIPMENT FOR A

COMPLETE AND USEABLE SYSTEM - SEE ELECTRICAL PLAN E-604, DETAIL A, AND

SPECIFICATION SECTION 28 20 01.00 10 ENTRY CONTROL SYSTEM. VERIFY WITH

CONTRACTING OFFICER.

HW-17

6 EA. HINGES, A5111 630

2 EA. CLOSER, C02011

(PARALLEL ARM)(PAINT TO 600

MATCH ADJACENT DOOR FRAME)

2 EA. EXIT DEVICE, TYPE 08, FUNCTION 08 646

(LOCKSET PROVIDED BY EXIT DEVICE MFR.)

4 EA. SILENCERS, RUBBER

1 EA. METAL THRESHOLD 719

2 EA. DUSTPROOF STRIKE, L04021 646

1 EA. METAL THRESHOLD (FIRE RATED)

1 EA. DOOR STOP,L02161(DOME TYPE) 646

HW-18

3 EA. HINGES, A5111 630

1 EA. CLOSER, C02011

(HINGE SIDE MOUNT)(PAINT TO 600

MATCH ADJACENT DOOR FRAME)

1 EA. EXIT DEVICE, TYPE 08, FUNCTION 08 646

(LOCKSET PROVIDED BY EXIT DEVICE MFR.)

3 EA. SILENCERS, RUBBER

1 EA. METAL THRESHOLD (FIRE RATED)

1 EA. DUSTPROOF STRIKE, L04021 646

HW-19

3 EA. HINGES,A5111 (4-1/2" X 4-1/2") 630

08 71 00- 17 AM-06

1.3.2 Floor Panels

Floor panel testing shall be conducted in accordance with CISCA Access Floors. When tested as specified, all deflection and deformation measurements shall be made at the point of load application on the top surface of the panel. Floor panels shall be capable of supporting the following loads:

a. Concentrated load of 1000 pounds on one square inch, at any point on panel, without deflecting more than 0.08 inch, with a safety factor of 2 based on static design load, without permanent deformation in excess of 0.01 inch in any of the specified tests.

b. Uniform live load of 250 psf, without deflecting more than 0.04 inch.

c. An impact load of 800 pounds on one square inch from a height of 12 inches with permanent set not to exceed 0.060 inch.

1.3.3 Grounding

The access flooring system shall be grounded for safety hazard and static suppression. Provide positive contact between components for safe, continuous electrical grounding of entire floor system. Total system resistance from wearing surface of floor to building grounding electrode shall be within range of 0.5 to 20,000 megohms.

1.4 DELIVERY, STORAGE, AND HANDLING

1.4.1 Delivery

Deliver materials to site in undamaged condition, in original containers or packages, complete with accessories and instructions. Label packages with manufacturer's name and brand designations. Where materials are covered by referenced specification, containers or packages shall also bear specification number, type, and class as applicable.

1.4.2 Storage

Materials shall be stored in original protective packaging in a safe, dry, and clean location. Panels shall be stored at temperatures between 40 and 90 degrees F, and between 20 and 70 percent humidity. Replace defective or damaged materials.

1.4.3 Handling

Materials shall be handled and protected in a manner to prevent damage during the entire construction period.

1.5 EXTRA MATERIALS

a. ARMY: Spare floor panels, and spare complete pedestal assemblies shall be furnished at the rate of one space for each 100 or fraction thereof required.

1.6 DETAIL DRAWINGS

The Contractor shall take measurements from finished areas at site and

09 69 00- 6 AM-06

The size shall be as shown in the drawings.

2.5.2 Vinyl Covered

Tackboard shall have a vinyl wall covering laminated to a minimum 1/4 inch thick cork laminated to a minimum 1/4 inch thick hardboard or particleboard, and shall have an aluminum frame. The size shall be as shown in the drawings.

2.5.3 Fabric Covered

Tackboard shall have a woven fabric covering laminated to a minimum 1/4 inch thick cork laminated to a minimum 1/4 inch thick hardboard or particleboard, and shall have an aluminum frame. The size shall be as shown on the drawings.

2.6 DISPLAY TRACK SYSTEM

This method of display shall be a flexible and interchangeable system that consists of lightweight presentation components suspended from a wall mounted, linear, horizontal track. Track shall have one levels to attach components.

Track shall allow attached components to slide horizontally. Presentation components shall be capable of being lifted from the track and being relocated to allow for reconfiguration. Components shall be capable of being installed on the track without the use of tools for installation, removal, and reconfiguration. The presentation components shall consist of a reversible panel with dry-erase markerboard on one side and woven fabric covered tacksurface on the other. Components shall be installed and located on track in accordance with manufacturer recommendations. Marker boards shall be provided with a marker tray. Marker board surface shall accept magnets. Dry erase markings on the marker board shall be removable with a felt eraser or dry cloth without ghosting. Each unit shall come complete with an eraser and four different color compatible dry erase markers. The sizes shall be as shown in the drawings.

Track and trim materials shall be standard products of the manufacturer. (DT1) or equal to.

2.7 HORIZONTAL SLIDING UNITS

The horizontal sliding unit shall be composed of a fixed back panel, sliding panels, an aluminum track assembly, and shall have a map rail and chalktray.

The unit shall have 2 tracks. The fixed back panel shall be markerboard. The unit shall have 2 marker board sliding panel and 1 tackboard sliding panel. The track assembly and exposed members, including panel edging and chalktray, shall be extruded aluminum. Frame assembly shall be reinforced at corners. Sliding panels shall be suspended from the top and shall slide over the aluminum track using molded nylon ball bearing rollers at the top of the track and nylon guide rollers at the bottom of the track to eliminate vibration and to provide quiet and smooth operation of the panels. Sliding panels shall have finger pulls at each end. The map rail shall have a tackable insert and extend the length of the horizontal sliding unit. The map rail shall have map hooks with clips for holding sheets of paper. Two map hooks shall be provided for each 4 foot of map rail. Chalktray shall extend the full length of the horizontal sliding unit.

Dry erase markings on the marker board shall be removable with a felt eraser or dry cloth without ghosting. Each unit shall come complete with an eraser and four different color compatible dry erase markers. The size shall be as shown in the drawings.

10 10 00- 6 AM-06

installed. Six copies of maintenance instructions listing routine procedures, repairs, and guides shall be provided. The instructions shall include the manufacturer's name, model number, service manual, parts list, and brief description of all equipment and their basic operating features. Each set shall be permanently bound and shall have a hard cover. The following identification shall be inscribed on the covers: the words "OPERATING AND MAINTENANCE INSTRUCTIONS", name and location of the facility, name of the Contractor, and contract number.

1.3 GENERAL

Interior signage shall be of the design, detail, sizes, types, and message content shown on the drawings/attachments/signage placement schedule (as applicable), shall conform to the requirements specified, and shall be provided at the locations indicated. Signs shall be complete with lettering, framing as detailed, and related components for a complete installation. Signage shall be obtained from a single manufacturer with edges and corners of finished letterforms and graphics true and clean.

Recyclable materials shall conform to EPA requirements in accordance with Section 01 62 35 RECYCLED / RECOVERED MATERIALS.

1.4 QUALIFICATIONS

Signs, plaques, and dimensional letters shall be the standard product of a manufacturer regularly engaged in the manufacture of such products and shall essentially duplicate signs that have been in satisfactory use at least 2 years prior to bid opening.

1.5 DELIVERY AND STORAGE

Materials shall be packaged to prevent damage and deterioration during shipment, handling, storage and installation. Product shall be delivered to the jobsite in manufacturer's original packaging and stored in a clean, dry area in accordance with manufacturer's instructions.

1.6 EXTRA STOCK

The Contractor shall provide 10 extra frames and extra stock of the following: 10 blank plates of each color and size for sign types 4 and 5.

3 extra letters in each color and size for sign type 2 and 3. 100 changeable message strips for sign type 8 and 9.

PART 2 PRODUCTS

2.1 ROOM IDENTIFICATION/DIRECTIONAL SIGNAGE SYSTEM

2.1.1 Standard Room Signs

Signs shall consist of laminated thermosetting Type MP plastic (three-ply melamine plastic laminate with phenolic core) and shall conform to the following:

Window Plaque frames shall be metal. Frames shall be manufacturer's standard width.

Typical room sign units shall be frameless. Corners of signs shall be squared.

10 14 02- 5 AM-06

2.2.5.2 Update Terminal

Update terminal unit shall consist of a 19 inch color monitor with 101 key keypad. Unit shall have a 132 column report printer. Unit shall include a Pentium 75 or better PC processor with floppy disk from update terminal to each directory. System shall include network from update to each directory.

Communications shall be over a telephone network or a LAN.

2.3 METAL PLAQUES

2.3.1 Chemically Etched Metal Plaques

2.3.1.1 Fabrication

Plaque shall be chemically double- etched one-piece zinc 0.125 inch thick.

2.3.1.2 Finish

Double-etched raised areas shall be silver-tone and recessed textured areas shall be gold-tone colorfilled.

2.4 DIMENSIONAL BUILDING LETTERS

2.4.1 Fabrication

Letters shall be fabricated from cast aluminum. Letters shall be cleaned by chemical etching or cleaned ultrasonically in a special degreasing bath. Letters shall be packaged for protection until installation.

2.4.2 Typeface

Typeface shall be helvetica medium.

2.4.3 Size

Letter size shall be16 inches high.

2.4.4 Finish

Baked enamel or two-component acrylic polyurethane finish shall be provided.

2.4.5 Mounting

Steel U-bracket, cap screws, and expansion bolts of number and size recommended by manufacturer, shall be supplied for concealed anchorage.

Letters which project from the mounting surface shall have stud spacer sleeves. Letters, studs, and sleeves shall be of the same material.

Templates for mounting shall be supplied.

2.5 ALUMINUM ALLOY PRODUCTS

Aluminum extrusions shall be at least 1/8 inch thick, and aluminum plate or sheet shall be at least 0.0508 inch thick. Extrusions shall conform to ASTM B 221; plate and sheet shall conform to ASTM B 209. Where anodic coatings are specified, alloy shall conform to AA PK-1 alloy designation

514.0. Exposed anodized aluminum finishes shall be as shown. Welding for aluminum products shall conform to AWS D1.2/D1.2M.

10 14 02- 8 AM-06

Provide bright polish finish.

2.2.11 Toilet Seat Cover/Tissue Dispenser/Waste Receptacle (TSCTDWR) Provide stainless steel and partition mounted toilet seat cover, tissue dispenser, and waste receptacle combination. Provide a minimum of 500 seat covers per side and 4 (2 per side) standard tissue rolls for each dispenser.

Provide a waste receptacle with removable leak-proof receptacle for disposable liners. Provide fifty disposable liners of the type standard with the manufacturer. Retain receptacle in cabinet by tumbler lock. Provide disposer with a door for inserting disposed napkins. Furnish tumbler key lock locking mechanism.

2.2.12 Hand Sanitizer Dispenser (HSD)

Provide hand sanitizer dispensers where indicated on the drawings. Hand sanitizer dispenser shall be a wall mounted, battery operated, top fill, automatic, touchless type that dispenses sanitizer when a hand is placed in proximity of a sensor. Dispenser shall have a view window to monitor quantity of hand sanitizer product remaining. Dispenser shall have a small tray below the dispensing portal to catch wasted sanitizer. Batteries shall be of a standard size such as AA cells. Dispenser shall be similar to products manufactured by Purell, Sloan or approved equal. Contractor shall supply and install sanitizer dispensers complete with mounting brackets, batteries as recommended by manufacturer, sanitizer solution, and one bottle of refill sanitizer solution

2.2.113 Mop and Broom Holder (MBH)

Mop and broom holder shall be 18 gauge, type 304 stainless steel, satin finish;

located as indicated on the drawings, to clear ceramic tile wainscots, be 16 inches long. Mop and broom holders consist of a minimum three spring activated rubber cams on plated steel retainers.for each dispenser installed.

PART 3 EXECUTION

3.1 INSTALLATION

Provide the same finish for the surfaces of fastening devices exposed after installation as the attached accessory. Provide oval exposed screw heads.

Install accessories at the location and height indicated. Protect exposed surfaces of accessories with strippable plastic or by other means until the installation is accepted. After acceptance of accessories, remove and dispose of strippable plastic protection. Coordinate accessory manufacturer's mounting details with other trades as their work progresses. Use sealants for brackets, plates, anchoring devices and similar items in showers (a silicone or polysulphide sealant) as they are set to provide a watertight installation.

After installation, thoroughly clean exposed surfaces and restore damaged work to its original condition or replace with new work.

3.1.1 Recessed Accessories

Set anchors in mortar in masonry construction. Fasten to metal studs or framing with sheet metal screws in metal construction.

3.1.2 Surface Mounted Accessories

Mount on concealed backplates, unless specified otherwise. Conceal fasteners on accessories without backplates. Install accessories with sheet metal screws or wood screws in lead-lined braided jute, teflon or neoprene sleeves, or lead expansion shields, or with toggle bolts or other approved fasteners as required by the construction. Install backplates in the same manner, or provide with lugs or anchors set in mortar, as required by the construction. Fasten accessories mounted on gypsum board and plaster walls without solid backing into the metal studs, or to metal

10 28 13- 5 AM-06

Amendment No. 6 - Technical Specification Changes
06 61 16 - 9
08 71 00 - 9
08 71 00 - 13
08 71 00 - 17
09 69 00 - 6
10 10 00 - 6
10 14 02 - 5
10 14 02 - 8
10 28 13 - 5

File details come from the government source that posted it. Updated .