OSUT_1_12_48_13_13_Entrance_Floor_Mats.pdf

PDF 54 KB Posted

Attached to
Armor OSUT 1
Solicitation number
W911SF-19-R-0018
Issued by

About this file

Floor Mats

View the file

Other files

File Type Posted
ARMOR_OSUT_1_-_5_Pre_Award_Addendum_1.pdf PDF
W911SF19R00180004.pdf PDF
Lafayette_Pool_Oscar_15_Nad_83_Grading_Plan_Sheet_1_Amended_12_July_2019.._.pdf PDF
Attachment_4_Performance_Assessment_Questionnaire.pdf PDF
44026_Stevon_Booker_Oscar_14_Nad_83_Grading_Plan_.pdf PDF
Blank_Bid_Breakdown_Form.xlsx XLSX spreadsheet
ARMOR_OSUT_Site_Visit_Attendees.pdf PDF
ARMOR_OSUT_1_-_5_General_Questions.pdf PDF
W911SF19R00180003.pdf PDF
44026_Stevon_Booker_Oscar_14_Nad_83_Site_Plan_Mod.pdf PDF
Armor_OSUT_1__Questions.pdf PDF
OSUT_1_32_01_19_Field_Molded_Sealants_for_Sealing_Jts_In_Rigid_Pavg.pdf PDF
OSUT_1_08_33_13.00_10_Metal_Rolling_Counter_Doors.pdf PDF
OSUT_1_23_00_00_Air_Supply_Venti_and_Exhaust_Sys.pdf PDF
OSUT_1_01_35_29_Safety_and_Occupational_Health_Requirements.pdf PDF
OSUT_1_06_41_16_00_Laminate_Clad_Architectural_Casework.pdf PDF
OSUT_1_26_41_01_Lightning_Protection_System.pdf PDF
OSUT_1_05_30_00_Steel_Decks.pdf PDF
OSUT_1_09_51_00_Acoustical_Ceilings.pdf PDF
OSUT_1_05_51_00_Metal_Stairs.pdf PDF
OSUT_1_01_78_02_00_10_Closeout_Submittals.pdf PDF
OSUT_1_Latrine_Combined.pdf PDF
OSUT_1_01_74_19_Construction_and_Demolition_Waste_Management.pdf PDF
OSUT_1_11_42_01_Food_Serving_Tables.pdf PDF
OSUT_1_01_45_01_Quality_Control.pdf PDF
OSUT_1_01_78_23_Operation_an_Maintenace_Data.pdf PDF
OSUT_1_10_14_02_Interior_Signage.pdf PDF
OSUT_1_23_37_13_Diffusers,_Registers,_and_Grills.pdf PDF
OSUT_1_Control_Tower_CMU_Combined.pdf PDF
OSUT_1_07_84_00_Firestopping.pdf PDF
OSUT_1_06_10_00_Rough_Carpentry.pdf PDF
OSUT_1_09_65_00_Resilient_Flooring.pdf PDF
OSUT_1_01_11_0_Summary_of_Work.pdf PDF
OSUT_1_02_84_16_PCB_Trans_Hazard_Waste_Lamp_Removal.pdf PDF
OSUT_1_23_23_00_Refrigerant_Piping.pdf PDF
OSUT_1_07_25_00_Building_Air_Barrier_System.pdf PDF
OSUT_1_C2_Facility_Combined.pdf PDF
OSUT_1_44026_Stevon_Booker_Oscar_14_Nad_83_Site_Plan_Mod.pdf PDF
OSUT_1_09_90_00_Paints_and_Coatings.pdf PDF
OSUT_1_01_42_00_Sources_for_Referencece_Publications.pdf PDF
OSUT_1_12_24_13_Roller_Window_Shades.pdf PDF
OSUT_1_08_91_00_Metal_Wall_Louvers.pdf PDF
OSUT_1_28_31_76_Interior_Fire_Alarm_and_Mass_Notification_Sys.pdf PDF
OSUT_1_23_05_93_Testing,_Adjusting,_and_Balancing_for_HVAC.pdf PDF
OSUT_1_05_50_13_Miscellaneous_Metal_Fabrication.pdf PDF
OSUT_1_01_50_00_Temporary_Construction_Faclities_and_Controls.pdf PDF
OSUT_1_08_11_13_Steel_Doors_and_Frames.pdf PDF
W911SF-19-R-0018-0001,_ARMOR_OSUT_1,_Amend_0001.pdf PDF
OSUT_1_26_28_01_Coordinated_Power_System_Protection.pdf PDF
OSUT_1_32_31_13_High-Security_Chain_Link_Fences.pdf PDF
Show 40 more

Latest 50 of 126 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OUST-AR RANGE PROJECTS FY19

SECTION 12 48 13.13

ENTRANCE FLOOR MATS

05/09

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM C 501 (1984; R 2002) Relative Resistance to Wear of Unglazed Ceramic Tile by the Taber Abraser

ASTM D 2047 (2004) Static Coefficient of Friction of Polish-Coated Floor Surfaces as Measured by the James Machine

ASTM D 2240 (2005) Standard Test Method for Rubber Property - Durometer Hardness

ASTM E 648 (2009a) Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

ASTM F 150 (2006) Electrical Resistance of Conductive and Static Dissipative Resilient Flooring

ASTM F 1869 (2004) Measuring Moisture Vapor Emission Rate of Concrete Subfloor Using Anhydrous Calcium Chloride

CARPET AND RUG INSTITUTE (CRI)

CRI 104 (2002) Standard for Installation Specification of Commercial Carpet

U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)

40 CFR 247 Comprehensive Procurement Guideline for Products Containing Recovered Materials

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-03 Product Data

Submit Manufacturer's Data and indicate percentage of recycled material content in protective flooring materials Entrance and Floor Mats to verify affirmative procurement compliance.

Submit total weight and volume quantities of protective flooring materialswith recycle materials content.

SD-04 Samples

Submit manufacturer's standard color charts for Entrance and Floor Mats showing the manufacturer's recommended color and finish selections.

Submit one sample 12 inch square, assembled sections of floor mat to show corners, intersections, and other details of construction. Provide any graphics in drawing for approval.

1.3 QUALITY ASSURANCE

Comply with Section 4.5 in the U.S. Architectural & Transportation Barriers Compliance Board's "Americans with Disabilities Act (ADA), Accessibility Guidelines for Buildings and Facilities (ADAAG) for installed entrance and floor mats.

Submit documentation of testing and compliance with the following standards:

a. Rubber based products: ASTM C 501, ASTM D 2047, ASTM D 2240.

b. Carpet based products: ASTM E 648, ASTM F 150, CRI 104.

c. Other materials: ASTM C 501, ASTM D 2047, ASTM D 2240, ASTM E 648, ASTM F 150, ASTM F 1869.

PART 2 PRODUCTS

2.1 AFFIRMATIVE PROCUREMENT

The Environmental Protection Agency (EPA) has designated certain items which must contain a specified percent range of recovered or recycled materials. EPA designated products specified in this contract comply with the stated policy and with the EPA guidelines. Make all reasonable efforts to use recycled and recovered materials in providing the EPA designated products and in otherwise utilizing recycled and recovered materials in the execution of the work. These items, when incorporated into the work under this contract, are to contain at least the specified percentage of recycled or recovered materials unless adequate justification (non-availability) for non-use is provided, per 40 CFR 247.

Mats are listed in the EPA's Comprehensive Procurement Guidelines (CPG ) at http://www.epa.gov/epaoswer/non-hw/procure/products/mats.htm.

EPA's recommended Recovered Materials Content Levels for Mats.

Product Material Percent Of Post Percent Of Total Consumer Materials Recovered Product Material Percent Of Post Percent Of Total Consumer Materials Recovered Materials

Mats Rubber 75 - 100 85 - 100

Plastic 10 - 100 100

Rubber/ 100 100 Plastic composite

The recommended recovered materials content levels are based on the dry weight of the raw materials, exclusive of any additives such as adhesives, binders, or coloring agents. EPA's recommendation does not preclude procuring agencies from purchasing mats manufactured from another material.

It simply recommends that procuring agencies, when purchasing mats made from rubber or plastic, purchase these items made from recovered materials.

For informational purposes, a list of known sources for mats using recycled material is provided in the EPA/CPG Supplier database at http://www.ergweb2.com/cpg4review/user/cpg_search.cfm.

Note that the Contractor is not limited to these sources. A product meeting CPG recycle requirements from other sources may be submitted for the Government's approval.

Submit recycled material content data for protective flooring materials indicating compliance with affirmative procurement.

Submit total weight and volume quantities of protective flooring materials with recycle material.

2.2 TYPE OF MATS

2.2.1 Entrance and Floor Mats

Furnish the following type of entrance mat:

Walk-off floor mats shall be flush with adjacent flooring; size and locations shall be as indicated on the drawings. Mats shall be extruded aluminum single tread design joined structurally by aluminum key lock bars. Each tread shall have manufacturer's carpet. Treads shall be maximum 1 1/2 inches wide by 1/2 inch high. Maximum tread spacing shall be 1 1/2 inches on center. Each aluminum tread shall have two continuous cushion strips interlocked on the underside of the tread.

Each mat shall be bordered by a recessed aluminum angle frame. Exposed aluminum on treads shall be anodized finish. Color of aluminum and abrasive strip shall be as indicated in Finish Schedule on drawings.

PART 3 EXECUTION

3.1 DELIVERY OF MATERIALS

Deliver materials to the project site in their original packages or containers bearing labels clearly identifying the manufacturer, brand name, and quality or grade.

Store materials in their original unbroken packages or containers in the area in which they will be installed. Unwrap, inspect, and place mats at indicated location.

Remove and dispose all excess packing materials.

3.2 EXAMINATION

Comply with manufacture's requirements of substrates and floor conditions for location, sizes, and other conditions affecting installation of floor mats and frames.

3.3 INSTALLATION

Install only in satisfactory conditions. Comply with manufacturer's written printed instructions for recessed mat frames. Set mat tops at height recommended by manufacturer for most effective cleaning action.

Coordinate top of mat surfaces with bottom of doors that swing across mats to provide clearance between doors and mat.

Install grout and fill around frames and, if required to set mat tops at proper elevations, in recesses under mats. Finish grout and fill smooth and level. Install surface-type units to comply with manufacturer's written printed instructions at locations indicated. Coordinate with other trades, entrance locations and traffic patterns.

-- End of Section --

File details come from the government source that posted it.