OUST-AR RANGE PROJECTS FY19
SECTION 09 51 00
ACOUSTICAL CEILINGS
10/07
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM A 1008/A 1008M (2009a) Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy and High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardened
ASTM A 167 (1999; R 2009) Standard Specification for Stainless and Heat-Resisting Chromium-Nickel Steel Plate, Sheet, and Strip
ASTM A 489 (2004e1) Standard Specification for Carbon Steel Lifting Eyes
ASTM A 580/A 580M (2008) Standard Specification for Stainless Steel Wire
ASTM A 641/A 641M (2009a) Standard Specification for Zinc-Coated (Galvanized) Carbon Steel Wire
ASTM A 653/A 653M (2009a) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process
ASTM B 633 (2007) Standard Specification for Electrodeposited Coatings of Zinc on Iron and Steel
ASTM C 423 (2009a) Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method
ASTM C 635/C 635M (2007) Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-In Panel Ceilings
ASTM C 636/C 636M (2008) Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels
ASTM C 834 (2005) Latex Sealants
ASTM E 119 (2009c) Standard Test Methods for Fire Tests of Building Construction and Materials
ASTM E 1264 (2008) Acoustical Ceiling Products
ASTM E 1414 (2006) Airborne Sound Attenuation Between Rooms Sharing a Common Ceiling Plenum
ASTM E 1477 (1998a; R 2008) Luminous Reflectance Factor of Acoustical Materials by Use of Integrating-Sphere Reflectometers
ASTM E 580/E 580M (2009a) Application of Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels in Areas Requiring Moderate Seismic Restraint
ASTM E 795 (2005) Mounting Test Specimens During Sound Absorption Tests
ASTM E 84 (2009c) Standard Test Method for Surface Burning Characteristics of Building Materials
U.S. DEPARTMENT OF DEFENSE (DOD)
UFC 3-310-04 (2007) Seismic Design for Buildings
UNDERWRITERS LABORATORIES (UL)
UL Fire Resistance (2009) Fire Resistance Directory
1.2 SYSTEM DESCRIPTION
Provide sound controlling units mechanically mounted on a ceiling suspension system for acoustical treatment. The unit size, texture, finish, and color must be as specified. The location and extent of acoustical treatment shall be as shown on the approved detail drawings.
Coordinate with paragraph RECLAMATION PROCEDURES for reclamation of mineral fiber acoustical ceiling panels to be removed from the job site.
1.2.2 Ceiling Attenuation Class and Test
Provide a ceiling system with an attenuation class (CAC) of 35 for when determined in accordance with ASTM E 1414. Provide fixture attenuators over light fixtures and other ceiling penetrations, and provide acoustical blanket insulation adjacent to partitions, as required to achieve the specified CAC. Provide test ceiling continuous at the partition and assembled in the suspension system in the same manner that the ceiling will be installed on the project.
1.2.3 Ceiling Sound Absorption
Determine the Noise Reduction Coefficient (NRC) in accordance with ASTM C 423 Test Method.
1.2.4 Light Reflectance
Determine light reflectance factor in accordance with ASTM E 1477 Test Method.
1.3 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Approved Detail Drawings
Drawings showing suspension system, method of anchoring and fastening, details, and reflected ceiling plan.
SD-03 Product Data; G
Acoustical Ceiling Systems
a. Manufacturer's data indicating percentage of recycle material in acoustic ceiling tiles to verify affirmative procurement compliance.
b. Total weight and volume quantities of acoustic ceiling tiles with recycle material.
c. Manufacturer's catalog showing UL classification of fire-rated ceilings giving materials, construction details, types of floor and roof constructions to be protected, and UL design number and fire protection time rating for each required floor or roof construction and acoustic ceiling assembly.
SD-04 Samples
Acoustical Units Acoustic Ceiling Tiles
Two samples of each type of acoustical unit and each type of suspension grid tee section showing texture, finish, and color.
SD-06 Test Reports
Fire Resistive Ceilings Ceiling Attenuation Class and Test
Reports by an independent testing laboratory attesting that acoustical ceiling systems meet specified requirements. Data attesting to conformance of the proposed system to Underwriters Laboratories requirements for the fire endurance rating listed in UL Fire Resistance may be submitted in lieu of test reports.
SD-07 Certificates
Acoustical Units Acoustic Ceiling Tiles
Certificate attesting that the mineral based acoustical units furnished for the project contain recycled material and showing an estimated percent of such material.
1.4 DELIVERY, STORAGE. AND HANDLING
Deliver materials to the site in the manufacturer's original unopened containers with brand name and type clearly marked. Carefully handle and store materials in dry, watertight enclosures. Immediately before installation, store acoustical units for not less than 24 hours at the same temperature and relative humidity as the space where they will be installed in order to assure proper temperature and moisture acclimation.
1.5 ENVIRONMENTAL REQUIREMENTS
Maintain a uniform temperature of not less than 60 degrees F nor more than 85 degrees F and a relative humidity of not more than 70 percent for 24 hours before, during, and 24 hours after installation of acoustical units.
1.6 SCHEDULING
Complete and dry interior finish work such as plastering, concrete and terrazzo work before ceiling installation. Complete mechanical, electrical, and other work above the ceiling line; install and start operating heating, ventilating, and air conditioning systems in order to maintain temperature and humidity requirements.
1.7 WARRANTY
Provide manufacturer's standard performance guarantees or warranties that extend beyond a one year period. Include an agreement to repair or replace acoustical panels that fail within the warranty period in the standard performance guarantee or warranty. Failures include, but are not limited to, sagging and warping of panels; rusting and manufacturers defects of grid system.
1.8 EXTRA MATERIALS
Furnish spare tiles, from the same lot as those installed, of each color at the rate of 5 tiles for each 1000 tiles installed.
PART 2 PRODUCTS
2.1 ACOUSTICAL UNITS
Comply with EPA requirements in accordance with Section 01 62 35 RECYCLED / RECOVERED MATERIALS. Conform acoustical units to ASTM E 1264, Class A, and the following requirements:
2.1.1 Affirmative Procurement
Mineral Wool, Cellulose, and Laminated Paperboard used in acoustic ceiling tiles are materials listed in the EPA's Comprehensive Procurement Guidelines (CPG) (http://www.epa.gov/cpg/). EPA's recommended Recovered Materials Content Levels for Mineral Wool, Cellulose, Structural Fiberboard and Laminated Paperboard are:
Product Material Percent of Post Percent of Total Consumer Materials Recovered Materials
Laminate Post Consumer Paper 100 100 Paperboard
Rock Wool Slag 75
Cellulose Post Consumer Paper 75 75
a. The recommended recovered materials content levels are based on the weight (not volume) of materials in the insulating core only.
b. For informational purposes, a list of known sources for acoustical ceiling tiles using recycled material is provided in the EPA/CPG Supplier database at http://www.ergweb2.com/cpg4review/user/cpg_search.cfm.
c. Note that the Contractor is not limited to these sources. A product meeting CPG recycle requirements from other sources may be submitted for the Government's approval.
d. Submit recycled material content data for acoustic ceiling tiles indicating compliance with affirmative procurement.
e. Submit total weight and volume quantities of acoustic ceiling tiles with recycle material.
2.1.2 ACT Type "B" Units for Exposed-Grid System
a. Type: III (non-asbestos mineral fiber with painted finish).
b. Flame Spread: Class A, 25 or less
c. Minimum NRC: 0.55.
e. Minimum Light Reflectance Coefficient: 0.85.
f. Nominal size: 24 by 24 inch.
g. Edge detail: square.
h. Finish: Factory-applied standard finish.
i. Minimum CAC: 35.
Metal Pans [A] [_____]
Type
[V, steel] [VI, ASTM A167 stainless steel] [VII, aluminum] perforated pans with acoustical, non-asbestos, insulation backing
Flame Spread
Class: A, 25 or less
Pattern
[A] [C] [I] [_____]
Minimum NRC
[0.75] [_____] in open office areas; [0.60] [_____] in conference rooms, executive offices, teleconferencing rooms, and other rooms as designated;
[0.50] [_____] in all other rooms and areas when tested on mounting Type E-400 of ASTM E795.
Minimum Light Reflectance Coefficient
[LR-1, 0.75 or greater] [_____]
Nominal Size
[24 by 24] [_____] inch
Edge Detail
Manufacturer's standard.
Joint Detail
[Beveled] [_____]
Finish
Factory-applied standard finish
Pads
[Completely enclosed, of material and thickness required for acoustical and fire test ratings] [_____].
2.1.3 ACT Type "A" Impact/Abrasion Resistant Units
a. Type: Non-asbestos mineral composition with a hardened mineral surface and factory applied white paint finish. Provide a surface resistant to impact and abrasion.
b. Flame Spread Class A, 25 or less
c. Pattern textured fine fissured
d. Minimum NRC 0.50 when tested on Mounting Type E-400 of ASTM E795.
e. Minimum Light Reflectance Coefficient LR-1, 0.75 or greater
f. Nominal Size 24 by 24 inch
g. Edge Detail; Square
h. Joint Detail Trimmed and butted
2.1.4 ACT Type "C" Humidity Resistant Composition Units
a. Type: Non-asbestos mineral or glass fibers bonded with ceramic, moisture resistant thermo-setting resin, or other moisture resistant material and having a factory applied white paint finish.
Provide panels that do not sag or warp under conditions of heat, high humidity or chemical fumes.
b. Flame Spread Class: A, 25 or less
c. Pattern: smooth
d. Minimum NRC Minimum 0.50 when tested on Mounting Type E-400 of
ASTM E795.
e. Minimum Light Reflectance Coefficient LR-1, 0.75 or greater
f. Nominal Size: 24 x 24 inch
g. Edge Detail: Square
2.2 SUSPENSION SYSTEM
Provide standard exposed-grid suspension system conforming to ASTM C 635/C 635M for intermediate-duty systems. Provide surfaces exposed to view of aluminum or steel with a factory-applied white. Provide wall molding having a flange of not less than 15/16 inch. Provide corners.
Suspended ceiling framing system must have the capability to support the finished ceiling, light fixtures, air diffusers, and accessories, as shown. Provide a suspension system with a maximum deflection of 1/360 of the span length. Conform seismic details to the guidance in UFC 3-310-04 and ASTM E 580/E 580M.
2.3 HANGERS
Provide hangers and attachment capable of supporting a minimum 300 pound ultimate vertical load without failure of supporting material or attachment.
2.3.1 Wires
Conform wires to ASTM A 641/A 641M, Class 1, 0.11 inch in diameter.
2.3.2 Straps
Provide straps of 1 by 3/16 inch galvanized steel conforming to ASTM A 653/A 653M, with a light commercial zinc coating or
ASTM A 1008/A 1008Mwith an electrodeposited zinc coating conforming to ASTM B 633, Type RS.
2.3.3 Rods
Provide 3/16 inch diameter threaded steel rods, zinc or cadmium coated.
2.6 FINISHES
Use manufacturer's standard textures, patterns and finishes as specified for acoustical units and suspension system members. Treat ceiling suspension system components to inhibit corrosion.
2.7 COLORS AND PATTERNS
Use colors and patterns for acoustical units and suspension system components as indicated on Color and Finish Schedule as selected and/or approved by the Government.
2.8 ACOUSTICAL SEALANT
Conform acoustical sealant to ASTM C834, nonstaining.
PART 3 EXECUTION
3.1 INSTALLATION
Examine surfaces to receive directly attached acoustical units for unevenness, irregularities, and dampness that would affect quality and execution of the work. Rid areas, where acoustical units will be cemented, of oils, form residue, or other materials that reduce bonding capabilities of the adhesive. Complete and dry interior finish work such as plastering, concrete, and terrazzo work before installation. Complete and approve mechanical, electrical, and other work above the ceiling line prior to the start of acoustical ceiling installation. Provide acoustical work complete with necessary fastenings, clips, and other accessories required for a complete installation. Do not expose mechanical fastenings in the finished work. Lay out hangers for each individual room or space. Provide hangers to support framing around beams, ducts, columns, grilles, and other penetrations through ceilings. Keep main runners and carrying channels clear of abutting walls and partitions. Provide at least two main runners for each ceiling span. Wherever required to bypass an object with the hanger wires, install a subsuspension system so that all hanger wires will be plumb.
3.1.1 Suspension System
Install suspension system in accordance with ASTM C 636/C 636M and as specified herein. Do not suspend hanger wires or other loads from underside of steel decking.
3.1.1.1 Plumb Hangers
Install hangers plumb and not pressing against insulation covering ducts and pipes. Where lighting fixtures are supported from the suspended ceiling system, provide hangers at a minimum of four hangers per fixture and located not more than 6 inch from each corner of each fixture.
3.1.1.2 Splayed Hangers
Where hangers must be splayed (sloped or slanted) around obstructions, offset the resulting horizontal force by bracing, countersplaying, or other acceptable means.
3.1.2 Wall Molding
Provide wall molding where ceilings abut vertical surfaces. Miter corners where wall moldings intersect or install corner caps. Secure wall molding not more than 3 inch from ends of each length and not more than 16 inch on centers between end fastenings. Provide wall molding springs at each acoustical unit in exposed systems.
3.1.3 Acoustical Units
Install acoustical units in accordance with the approved installation instructions of the manufacturer. Ensure that edges of acoustical units are in close contact with metal supports, with each other, and in true alignment. Arrange acoustical units so that units less than one-half width are minimized. Hold units in exposed-grid system in place with manufacturer's standard hold-down clips, if units weigh less than 1 psf or if required for fire resistance rating.
3.3 CLEANING
Following installation, clean dirty or discolored surfaces of acoustical units and leave them free from defects. Remove units that are damaged or improperly installed and provide new units as directed.
3.4 RECLAMATION PROCEDURES
Neatly stack ceiling tile, designated for recycling by the Contracting Officer, on 4 by 4 foot pallets not higher than 4 foot. Panels must be completely dry. Shrink wrap and symmetrically stack pallets on top of each other without falling over.
-- End of Section --