OUST-AR RANGE PROJECTS FY19
SECTION 08 33 13.00 10
METAL ROLLING COUNTER DOORS
04/06
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM A 240/A 240M (2004ae1) Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels for General Applications
ASTM A 653/A 653M (2004a) Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process
ASTM B 209 (2004) Aluminum and Aluminum-Alloy Sheet and Plate
ASTM B 209M (2004) Aluminum and Aluminum-Alloy Sheet and Plate (Metric)
ASTM B 221 (2005) Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes
ASTM B 221M (2005) Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric)
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 80 (1999) Fire Doors and Fire Windows
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for Contractor Quality Control approval. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government.
The following shall be submitted in accordance with Section 01 33 00
SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Approved Detail Drawings; G, RO
Drawings showing elevations of each door type, details of anchorage, details of construction, location and description of hardware, shape and thickness of materials, details of joints and connections, and details of guides and fittings. A schedule showing the location of each counter door shall be included with the drawings.
SD-03 Product Data
Rolling Counter Doors
Manufacturer's descriptive data and catalog cuts.
Installation Cleaning
Manufacturer's preprinted installation and cleaning instructions.
SD-10 Operation and Maintenance Data
Operation
Six complete copies of maintenance instructions listing routine maintenance procedures, possible breakdowns and repairs, troubleshooting guides, and simplified diagrams for the equipment as installed. Spare parts data for each different item of material and equipment specified shall be supplied not later than 3 days prior to the date of beneficial occupancy. The data shall include a complete list of parts and supplies, with current unit prices and source of supply, and a list of the parts recommended by the manufacturer to be replaced after 1 year and 3 years of service.
1.3 GENERAL REQUIREMENTS
Rolling counter doors shall be of the type, size, and design indicated on the drawings, and shall be the standard product of a manufacturer regularly engaged in the production of rolling counter doors. Each door shall be provided with a permanent label showing the manufacturer's name and address and the model number of the door.
1.4 DELIVERY AND STORAGE
Rolling counter doors shall be delivered to the jobsite wrapped in a protective covering with the brands and names clearly marked thereon.
Rolling counter doors shall be stored in accordance with the manufacturer's instructions in a dry location that is adequately ventilated and free from dust, water, or other contaminants, and in a manner that permits easy access for inspecting and handling. Doors shall be handled carefully to prevent damage. Damaged items that cannot be restored to like-new condition shall be replaced.
1.5 WARRANTY
Manufacturer's standard performance guarantees or warranties that extend beyond a 1 year period shall be provided.
PART 2 PRODUCTS
2.1 BASIC COMPONENTS
2.1.1 Curtain
The curtain shall be fabricated of 22 gauge Type 304 stainless steel slats conforming to ASTM A 240/A 240M, Type 304 or Type 430. Thickness of slat material shall be as required by width of opening. Slats shall be approximately 1-1/4 to 1-1/2 inch wide with a depth of crown of 1/2 inch.
Alternate slats shall be fitted with end locks to maintain curtain alignment. Bottom of curtain shall be provided with angle or tubular bar reinforcement matching the curtain, and fitted with a resilient bottom seal.
2.1.2 Jamb Guides
Guides shall be of 13 gauge minimum thickness stainless steel conforming to ASTM A 240/A 240M, Type 304 or Type 430.
2.1.3 Counterbalance Shaft Assembly
The curtain shall be coiled around a steel tube of sufficient thickness and diameter to prevent deflection exceeding 0.03 inch per foot. The barrel shall contain oil tempered helical steel torsion springs capable of sufficient torque to counterbalance the weight of the curtain. Springs shall be calculated to provide a minimum of 7,500 operating cycles (one complete cycle of door operation will begin with the door in the closed position, move to the full open position and return to the closed position).
2.1.4 Brackets
Brackets shall be a minimum 12 gauge thickness steel if flat plate, or 16 gauge thickness if there are a minimum of 3 returns of 3/4 inch width.
2.1.5 Hood
The hood shall be of 24 gauge stainless steel conforming to ASTM A 240/A 240M, Type 304 or Type 430.
2.1.6 Locks
The curtain shall be locked at each side of the bottom bar by an integral slide bolt suitable for padlocks by others. Lock shall be on the room side of the counter door. Pad locks and keying shall conform to Section 08 71 00
DOOR HARDWARE.
2.2 OMITTED
2.4 INTEGRAL FRAME ROLLING COUNTER DOOR
Integral frame rolling counter door shall be stainless steel. Jambs shall be formed to create guides for the curtain. Head and jambs shall be 16 gauge thickness. Counter shall be 14 gauge thickness.
2.5 OPERATION
2.5.1 Manual Operation
The curtain shall be operated by means of manual push-up with lift handles or continuous full width lift bar. Manual crank with removable handle.
2.5.2 OMITTED
2.7 FINISH
Exposed parts of the counter door, including the curtain, bottom rail, guides, and hood shall be of uniform finish and appearance. Stainless steel shall have a No. 4 finish. All other steel parts shall be given a shop coat of primer paint standard with the manufacturer.
PART 3 EXECUTION
3.1 INSTALLATION
Doors shall be installed in accordance with approved detail drawings and manufacturer's instructions. Anchors and inserts for guides, brackets, hardware, and other accessories shall be accurately located. Upon completion, doors shall be free from warp, twist, or distortion. Doors shall be lubricated, properly adjusted, and demonstrated to operate freely.
3.2 OMITTED
3.3 CLEANING
Stainless steel doors shall be cleaned in accordance with manufacturer's approved instructions.
-- End of Section --