This presolicitation notice is for the construction of five stream crossings at Fort McCoy, Wisconsin. The Mission and Installation Contracting Command at Fort McCoy requires a contractor to repair Bridge NRP03, construct Stream Crossing B03, construct Stream Crossing C11-1, construct Stream Crossing C11-4, and construct Stream Crossing C12-1. The work includes earthwork, installation of precast concrete piers and steel guardrails, erosion control, culverts, roadway construction, and landscaping. The North American Industry Classification System code for this work is 237310. The solicitation will be issued as an Invitation for Bids using procedures outlined in the FAR and DFARS. The requirement will be awarded as a single-award, firm fixed-price contract under a small business HubZone set-aside. The project value is estimated between $2-3 million. The period of performance must be completed by June 30, 2022. The solicitation is expected to be issued within 45 days, and interested parties can add themselves to the interested vendors list.
View the file
Other files for this federal contract opportunity
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G0.1
Fort McCoy, Wisconsin
BRIDGE NRP03 GUARDRAILS
AND SUPPORTS
NOTES
A. ANY UTILITIES AND STRUCTURES SHOWN ON PLAN
DRAWINGS ARE APPROXIMATE IN LOCATION AND
DESCRIPTION AND ARE BASED ON RECORDS AVAILABLE
TO THE GOVERNMENT OR ON SURFACE FEATURES
INDICATING THEIR EXISTENCE. THERE MAY BE OTHER
UTILITIES WITHIN THE PROJECT AREA WHICH ARE NOT
SHOWN. THE LACK OF UTILITIES ON PLAN DRAWINGS IS
NOT AN INDICATION OF A UTILITY-FREE PROJECT SITE.
B. NOTIFY ALL AFFECTED UTILITY COMPANIES OF
CONSTRUCTION OPERATIONS AT LEAST THREE
WORKING DAYS BEFORE BEGINNING WORK NEAR THEIR
FACILITIES. DO NOT BEGIN EXCAVATION WORK UNTIL
UNDERGROUND UTILITY LOCATIONS HAVE BEEN
MARKED OR THE UTILITY COMPANY HAS SENT NOTICE
THAT THE AREA IS CLEAR.
C. SCALES SHOWN ONLY APPLY WHEN THESE
DRAWINGS ARE PRINTED ON 22" x 34" PAPER. SCALES
ARE HALF SIZED WHEN PRINTED ON 11" x 17" PAPER.
PHONE: 608.782.3161
329 JAY ST, SUITE 301
LA CROSSE, WI 54601
www.sehinc.com
G0.2
DIGGERS HOTLINE
Dial or (800)242-8511 www.DiggersHotline.com
LOCATION MAP
GENERAL NOTES
C1.1
Horz Scale: 1:10 Vert Scale 1" = 5'
PLAN AND PROFILE - NRP-03
2 2 2
3 3 3
S5.0
Scale: 3/8" = 1'-0"
PLAN VIEW
Scale: 3/8" = 1'-0"
ABUTMENT & PIER PANELS SECTION
Scale: 3/8" = 1'-0"
ABUTMENT & PIER PANELS ELEVATION
4 5
S5.1
Scale: 3" = 1'-0"
GUIDERAIL POST A
Scale: 3" = 1'-0"
GUIDERAIL POST A BASE
Scale: 3" = 1'-0"
GUARDRAIL POST B
Scale: 3" = 1'-0"
GUARDRAIL POST B BASE
Scale: 1" = 1'-0"
CONCRETE PANELS
Scale: 1/2" = 1'-0"
END MARKER SIGNS