This document provides details on a federal contract opportunity to construct stream crossings on Fort McCoy in Wisconsin. The Mission and Installation Contracting Command at Fort McCoy is seeking a contractor to perform work including repairing an existing bridge, removing timber piers, installing new precast concrete piers and steel guardrails, performing earthwork and erosion control, re-aligning the structure on new piers, and conducting landscaping. Additional work includes constructing four new stream crossings involving concrete culverts, earthwork, roadway construction, concrete cable mats, erosion control, and landscaping. The work falls under NAICS code 237310 with a small business size standard of $39.5 million. The solicitation will be issued as an IFB and awarded as a single fixed-price contract with a period of performance ending 30 June 2022. The opportunity is set aside for small business concerns under the HubZone program. The total project value is estimated between $2-3 million.
View the file
Other files for this federal contract opportunity
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G0.1
Fort McCoy, Wisconsin
CONSTRUCT
TRAIL
STREAM CROSSING C12-1
NOTES
A. ANY UTILITIES AND STRUCTURES SHOWN ON PLAN
DRAWINGS ARE APPROXIMATE IN LOCATION AND
DESCRIPTION AND ARE BASED ON RECORDS AVAILABLE
TO THE GOVERNMENT OR ON SURFACE FEATURES
INDICATING THEIR EXISTENCE. THERE MAY BE OTHER
UTILITIES WITHIN THE PROJECT AREA WHICH ARE NOT
SHOWN. THE LACK OF UTILITIES ON PLAN DRAWINGS IS
NOT AN INDICATION OF A UTILITY-FREE PROJECT SITE.
B. NOTIFY ALL AFFECTED UTILITY COMPANIES OF
CONSTRUCTION OPERATIONS AT LEAST THREE
WORKING DAYS BEFORE BEGINNING WORK NEAR THEIR
FACILITIES. DO NOT BEGIN EXCAVATION WORK UNTIL
UNDERGROUND UTILITY LOCATIONS HAVE BEEN
MARKED OR THE UTILITY COMPANY HAS SENT NOTICE
THAT THE AREA IS CLEAR.
C. SCALES SHOWN ONLY APPLY WHEN THESE
DRAWINGS ARE PRINTED ON 22" x 34" PAPER. SCALES
ARE HALF SIZED WHEN PRINTED ON 11" x 17" PAPER.
PHONE: 608.782.3161
329 JAY ST, SUITE 301
LA CROSSE, WI 54601
www.sehinc.com
G0.2
LOCATION MAP
GENERAL NOTES
DIGGERS HOTLINE
Dial or (800)242-8511 www.DiggersHotline.com
C0.1
Scale: NTS
TYPICAL FINISHED SECTION
Scale: NTS
TYPICAL MARSH EXCAVATION
Scale: NTS
TYPICAL SECTION - WORKING/STAGING AREA
C0.2
Scale: 1/2" = 1'
CABLE CONCRETE SYSTEM DETAIL
Scale: 1/2" = 1'
TYPICAL FINISHED SECTION - CABLE CONCRETE
C0.3
OBJECT MARKER
C0.4
80 80
80 80
HIGH WATER
TURN AROUND
DON'T DROWN
DURING
IMPASSABLE
CHECK VEHICLE
CROSSING LIMITS
FEET
HIGH WATER
TURN AROUND
DON'T DROWN
DURING
IMPASSABLE
CHECK VEHICLE
CROSSING LIMITS
C1.1
Horz Scale: 1:20 Vert Scale 1" = 5'
PLAN AND PROFILE - C12-1
C1.2
Horz Scale: 1:10
PLAN DETAIL - C12-1
C3.1
S0.1
SUBSURFACE EXPLORATION
1"=40' HORIZONTAL, 1"=10' VERTICAL
GENERAL STRUCTURE PLAN
1"=5' HORIZONTAL
S5.0
S5.1