Attachment 3- Finalized Camera Descriptions.pdf

PDF 194 KB Posted

Attached to
Furnish and Install, Security Cameras
Solicitation number
W911S826QA019
Issued by

About this file

This document is a Camera/Monitoring Station Location Details specification outlining the placement and technical requirements for 14 cameras and 2 viewing stations across a multi-building facility.

The specification details camera installations across four ground-level areas (A, B, C, and D) and two second-floor areas (C and D). Ground Level Area A requires four cameras: Camera #1 (outdoor, NE corner, 90-degree minimum view), Camera #2 (outdoor, N wall, 180-degree minimum view), Camera #3 (indoor, NE wall, 180-degree minimum view), and Camera #14 (indoor, weapons cleaning room, 90-degree minimum view), with Viewing Station #1 mounted in the Armory on the SE wall. Area B requires Camera #4 (outdoor, SE wall, 90-degree minimum view). Area C specifies Camera #5 (outdoor, SE wall, 90-degree minimum view) and Camera #6 (indoor, W wall, 180-degree minimum view), with Viewing Station #2 in the Computer Shop on the SE wall. Area D requires Camera #7 (outdoor, W wall, 90-degree minimum view), Camera #8 (outdoor, SE wall, 90-degree minimum view), Camera #9 (indoor, S wall, 180-degree minimum view), and Camera #10 (outdoor, SW wall, 90-degree minimum view). Second Floor Area C requires Camera #11 (indoor, W wall, 90-degree minimum view) and Camera #12 (indoor, E wall, 180-degree minimum view with restricted field of view past Operations Office threshold). Second Floor Area D requires Camera #13 (indoor, SW wall, 90-degree minimum view). Each camera specification includes mounting location, indoor/outdoor designation, coverage area, and minimum field of view angle requirements.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CAMERA/MONITORING STATION LOCATION DETAILS

GROUND LEVEL – AREA A

Camera #1

OUTDOOR; Camera on NE corner of building, viewing NE vehicle gate, E parking lot, and E AFE entrances and roll-ups; 90-degree view minimum.

Camera #2

OUTDOOR; Camera on N wall facing N entry door, viewing N entry door, N entrance corridor, N weapons cleaning room, N roll up and driveway; 180-degree view minimum.

Camera #3

INDOOR; Camera on NE wall above N entry door, viewing armory door and down entire corridor; 180-degree view minimum.

Camera #14

INDOOR; Camera on NE wall inside weapons cleaning room, viewing roll up counter and entire room; 90-degree view minimum.

Viewing Station #1

Inside Armory mounted on the SE wall.

GROUND LEVEL – AREA B

Camera #4

OUTDOOR; Camera on SE wall of building outside Dive Locker, viewing Watercraft/Vehicle Maintenance roll ups and entry doors; 90-degree view minimum.

GROUND LEVEL – AREA C

Camera #5

OUTDOOR; Camera on SE wall outside Supply Offices, viewing Supply roll ups/entry doors and gym entry doors across street; 90-degree view minimum.

Camera #6

INDOOR; Camera on W wall above Computer Shop door, viewing E entry doors, lobby, elevator, staircase and corridor; 180-degree view minimum.

Camera #7

OUTDOOR; Camera on W wall, viewing W entry doors and staircase; 90-degree view minimum.

Viewing Station #2

Inside Computer Shop mounted on the SE wall.

GROUND LEVEL – AREA D

Camera #8

OUTDOOR; Camera on SE wall, viewing SE building entry doors; 90-degree view minimum.

Camera #9

INDOOR; Camera on S wall above S entry door, viewing entry door traffic and 4 X S Equipment Storage Corridors; 180-degree view minimum.

Camera #10

OUTDOOR; Camera on SW wall of building, viewing SW patio and staircase; 90-degree view minimum.

SECOND FLOOR – AREA C

Camera #11

INDOOR; Camera on W wall between Med Logistics office and Bathroom, viewing second floor elevator, E staircase, and corridor; 90-degree view minimum.

Camera #12

INDOOR Camera on E Wall next to Operations Office, viewing N/S/W corridor outside of Operations Office; Camera view will NOT include anything E past the threshold of the Operations Office entry door; 180-degree view minimum.

SECOND FLOOR – AREA D

Camera #13

INDOOR Camera on SW wall next to JTAC Simulator office, viewing S entry door and S staircase; 90-degree view minimum.

File details come from the government source that posted it. Updated .