The system comprises 14 cameras distributed across Ground Level Areas A, B, C, and D, plus Second Floor Areas C and D, along with two viewing stations. Ground Level Area A requires four cameras: Camera #1 positioned on the NE building corner with 90-degree minimum view of the NE vehicle gate and E parking lot; Camera #2 on the N wall with 180-degree view of the N entry door and corridor; Camera #3 indoors on the NE wall with 180-degree view of the armory and corridor; and Camera #14 indoors in the weapons cleaning room with 90-degree view. Viewing Station #1 is mounted inside the Armory on the SE wall. Ground Level Area B requires one outdoor camera (Camera #4) on the SE wall viewing the Dive Locker area with 90-degree minimum view. Ground Level Area C specifies Camera #5 outdoors on the SE wall with 90-degree view of supply roll-ups and gym entries, and Camera #6 indoors on the W wall with 180-degree view of entry doors, lobby, elevator, and corridor, with Viewing Station #2 mounted in the Computer Shop. Ground Level Area D requires three cameras: Camera #8 outdoor with 90-degree view of SE entry doors, Camera #9 indoor with 180-degree view of entry traffic and storage corridors, and Camera #10 outdoor with 90-degree view of the SW patio. Second Floor Area C specifies Camera #11 with 90-degree view of elevators and corridor, and Camera #12 with 180-degree view excluding the Operations Office interior. Second Floor Area D requires Camera #13 on the SW wall with 90-degree view of the S entry door and staircase. All cameras are designated as either INDOOR or OUTDOOR with specific wall mounting locations and minimum field-of-view requirements.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CAMERA/MONITORING STATION LOCATION DETAILS
GROUND LEVEL – AREA A
Camera #1
OUTDOOR; Camera on NE corner of building, viewing NE vehicle gate, E parking lot, and E AFE entrances and roll-ups; 90-degree view minimum.
Camera #2
OUTDOOR; Camera on N wall facing N entry door, viewing N entry door, N entrance corridor, N weapons cleaning room, N roll up and driveway; 180-degree view minimum.
Camera #3
INDOOR; Camera on NE wall above N entry door, viewing armory door and down entire corridor; 180-degree view minimum.
Camera #14
INDOOR; Camera on NE wall inside weapons cleaning room, viewing roll up counter and entire room; 90-degree view minimum.
Viewing Station #1
Inside Armory mounted on the SE wall.
GROUND LEVEL – AREA B
Camera #4
OUTDOOR; Camera on SE wall of building outside Dive Locker, viewing Watercraft/Vehicle Maintenance roll ups and entry doors; 90-degree view minimum.
GROUND LEVEL – AREA C
Camera #5
OUTDOOR; Camera on SE wall outside Supply Offices, viewing Supply roll ups/entry doors and gym entry doors across street; 90-degree view minimum.
Camera #6
INDOOR; Camera on W wall above Computer Shop door, viewing E entry doors, lobby, elevator, staircase and corridor; 180-degree view minimum.
Camera #7
OUTDOOR; Camera on W wall, viewing W entry doors and staircase; 90-degree view minimum.
Viewing Station #2
Inside Computer Shop mounted on the SE wall.
GROUND LEVEL – AREA D
Camera #8
OUTDOOR; Camera on SE wall, viewing SE building entry doors; 90-degree view minimum.
Camera #9
INDOOR; Camera on S wall above S entry door, viewing entry door traffic and 4 X S Equipment Storage Corridors; 180-degree view minimum.
Camera #10
OUTDOOR; Camera on SW wall of building, viewing SW patio and staircase; 90-degree view minimum.
SECOND FLOOR – AREA C
Camera #11
INDOOR; Camera on W wall between Med Logistics office and Bathroom, viewing second floor elevator, E staircase, and corridor; 90-degree view minimum.
Camera #12
INDOOR Camera on E Wall next to Operations Office, viewing N/S/W corridor outside of Operations Office; Camera view will NOT include anything E past the threshold of the Operations Office entry door; 180-degree view minimum.
SECOND FLOOR – AREA D
Camera #13
INDOOR Camera on SW wall next to JTAC Simulator office, viewing S entry door and S staircase; 90-degree view minimum.