EW
WH
EW
WH
D
WH
EW
S C A L E I N F E E T
241212 6
PANEL 'A'
PA
FENCE
VSAT
FOR VSAT EQUIPMENT
EXISTING CABLE ENTRY
N O
R T
H
COMMUNICATION PLAN
PA
BACK BOARD AND RACK
EXISTING COMMUNICATION
KEYED NOTES
N O
R T
H
S C A L E I N F E E T
241212 6
LIGHTING PLAN
A
AA
AA
LIGHTING CONTACTOR
NO SCALE
e e e e e e e e e e f f f f f f f f f
GENERAL NOTES
2 3
2 3
(2)- DATA (EXISTING)
EXISTING COMM.,
TO REMAIN
SWITCHES
3 WAY TOGGLE
EXISTING
NEW
S
EXISTING LIGHTING,
TO REMAIN
B B B B B
B B B B B
C C C
CCC
EXISTING
EXISTING LIGHTING,
TO REMAIN
a a aa a a a b b b bb bb b c c c c c cc d d d dd d d d
S3S3 c,da,b c,d
FROM MIDDLE WALL
TO REPLACE SWITCHES DEMO'D
NEW SWITCHES AND WIRING
TO PANEL 'A' NEW 30 AMP BREAKER)
208 VOLT (UTILIZE AWG 8
TO PANEL 'A' NEW 30 AMP BREAKER)
208 VOLT (UTILZE AWG 8
AWG 10 TO FIXTURES
FIXTURES e
AWG 10 TO FIXTURES
FIXTURES f
B B
B B
S e,f e,f
S3
S3
S a,b
D
D
E E
E
EE
E
P
P R
D M
A D
E
D I
R E
C T
O R
A T
O F
P U
B L I
C
W
R K
S
F O
R
L
O N
A
W
O
M I
S S
O U
R I
D E
S C
R I
P T I
O N
R E
V I
S I
O N
S
D A
T E
G A
Y
B E
R
E D
B
A P
P R
O V
E D
D A
T E
S U
B M I
T T
E D
C H
E C
K E
D
D R
A W
N
D E
S I
G N
E D
C O
O R
D I
N A
T I
O N
D A
T E
D A
T E
D A
T E
SCALE
DATE
PROJECT NO:
DRAWING NO:
OFSHEET
AS SHOWN
C.0004125
DPW 02643-5J
E5
F
N T
R A
L
I
S S
U E
A D
D I
T I
N
B
I
L D I
N G
C O
M M
U N I
C A
T I
P L
A N
L I
G H
T I
G
G G
A R
G G
A R
E L
L
C8030.22
22 OCT 15
TRAY TO REMAIN
EXISTING CABLE
CIRCUIT A-6
CIRCUIT A-6
120 VOLT
WIRING AND TEST.
ORIENTATION AS WHEN THEY WERE REMOVED FROM WALL. CONNECT TO SPEAKER
SIDES OF DOUBLE BEAM ARRANGEMENT IN APPROXIMATELY SAME LOCATION AND
INSTALL PA SPEAKERS WHICH WERE STORED FROM DEMOLITION. ATTACH TO OPPOSITE
MACHINE-PRINTED LABELS.
PURPOSES AND IN STRICT COMPLIANCE WITH ANSI/TIA/EIA-606-A. PROVIDE
RJ-45 JACK, AT THE PATCH PANEL AND ALL OTHER POINTS FOR IDENTIFICATION
OF THE RACK MOUNTED VOICE PATCH PANEL. LABEL THE FACEPLATE AT THE
PULL BOX. PUNCH DOWN THE CABLE ON THE RJ-45 VOICE JACK AND THE REAR
THERE SHALL BE NO MORE THAN 180 DEGREES OF BEND WITHOUT USE OF A
THE JACKS TO THE RACK UTILIZING CONDUIT (1" MIN.) AND CABLE TRAY.
EXISTING RACK MOUNTED, RJ45 VOICE PATCH PANEL. ROUTE THE CABLE FROM
(WITH WHITE JACKET) FROM EACH RJ-45 VOICE (WHITE) JACK TO THE
PROVIDE (1)-4 PAIR, 24 AWG, COPPER, PLENUM RATED, CAT 6 CABLE
PRINTED LABELS.
AND IN STRICT COMPLIANCE WITH ANSI/TIA/EIA-606-A. PROVIDE MACHINE-
AT THE PATCH PANEL AND ALL OTHER POINTS FOR IDENTIFICATION PURPOSES
RACK MOUNTED DATA PATCH PANEL. LABEL THE FACEPLATE AT THE RJ-45 JACK,
PUNCH DOWN THE CABLE ON THE RJ-45 DATA JACK AND THE REAR OF THE
BE NO MORE THAN 180 DEGREES OF BEND WITHOUT USE OF A PULL BOX.
TO THE RACK UTILIZING CONDUIT (1" MIN.) AND CABLE TRAY. THERE SHALL
RACK MOUNTED, RJ45 DATA PATCH PANEL. ROUTE THE CABLE FROM THE JACKS
(WITH BLUE JACKET) FROM EACH RJ-45 DATA (BLUE) JACK TO THE EXISTING
PROVIDE (1)-4 PAIR, 24 AWG, COPPER, PLENUM RATED, CAT 6 CABLE
30 AMP, 240 VOLT, 4 POLE LIGHTING
CONTACTOR WITH ELECTRICALLY HELD
CONTACTS IN NEMA 1 ENCLOSURE.
IN NEW WORK.
EXISTING TO REMAIN. CLEAN, RE-LAMP AND REPAIR ALL FIXTURES WHICH ARE RE-USED
7. LIGHT FIXTURES IN MECHANICAL ROOM, ALL EXISTING OFFICES AND LATRINES ARE
CLEAN, RELAMP AND REPAIR AS NEEDED.
HEAD EMERGENCY FIXTURES SHALL REMAIN AND SHALL BE USED IN NEW WORK. TEST,
6. ALL EXISTING LIGHTED EXIT SIGNS (EXCEPT DIRECTIONAL ON END WALL) AND DUAL
5. (5)- EXTERIOR LIGHTING FIXTURES ARE EXISTING TO REMAIN. (2)- ARE NEW.
AND SHALL BE RE-CONFIGURED TO ADD / REMOVE FIXTURES AS INDICATED.
IN BUILDING
WHICH CONTROL THE FIXTURES. SWITCH LEGS 'a', 'b', 'c' AND 'd' ARE EXISTING
4. LOWER-CASE LETTER ON BAY AND HALLWAY LIGHTING FIXTURES INDICATES SWITCHES
3. REFER TO PANELBOARD SCHEDULE FOR LIGHTING CIRCUIT ASSIGNMENTS.
OF HVAC SUPPLY AND RETURN VENTS.
2. PLACEMENT / POSITION OF LIGHTING FIXTURES TAKES PRECEDENCE OVER PLACEMENT
FIXTURE SCHEDULE, SHEET E1.
1. LIGHTING FIXTURES ARE TYPE 'A' UNLESS NOTED OTHERWISE. REFER TO LIGHTING
S3 S3