8030_a1v8.pdf

PDF 224 KB Posted

Attached to
Metal Building Addition to Building 2327, Fort Leonard Wood, MO
Solicitation number
W911S7-16-B-0019
Issued by

About this file

Drawing 1 of 22

View the file

Other files

File Type Posted
W911S7-16-B-0019_Bid_Abstract.pdf PDF
W911S7-16-B-0019-0002_Addition_to_Building_2327.pdf PDF
Attachment_A _Statement_of_Work_Final_16-B-0019_Amendment_0002.pdf PDF
8030_c1v8rev.pdf PDF
Questions_and_Answers__W911S7-16-D-0019_Final.pdf PDF
8030_s1v8.pdf PDF
8030_e6v8.pdf PDF
8030_m2.pdf PDF
8030_mi4.pdf PDF
8030_e5v8.pdf PDF
8030_c1v8.pdf PDF
8030_a3v8.pdf PDF
8030_mi2.pdf PDF
Attachment_A _Statement_of_Work_Final_16-B-0019_Amendment_0001.pdf PDF
8030_e2v8.pdf PDF
DBA_Wage_Determination _19_August_2016.pdf PDF
8030_m3.pdf PDF
8030_m4.pdf PDF
8030_a2v8.pdf PDF
8030_mi3.pdf PDF
8030_s2v8.pdf PDF
8030_s3v8.pdf PDF
W911S7-16-B-0019-0001_Addition_to_Bldg_2327 _Amendment.pdf PDF
8030_mi5.pdf PDF
8030_m1.pdf PDF
8030_e1v8.pdf PDF
8030_mi1.pdf PDF
8030_e3v8.pdf PDF
8030_e4v8.pdf PDF
16-B-0019_Site_Visit_Roster.pdf PDF
Attachment_B _Drawings_16-B-0019.pdf PDF
DBA_Wage_Determination_MO160019_29_July_2016.pdf PDF
Attachment_A _Statement_of_Work_Final_16-B-0019.pdf PDF
W911S7-16-B-0019_Addition_to_Bldg_2327_Solicitation.pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WAREHOUSE

C

EXISTING WAREHOUSE

BUILDING DESIGN LOADS:

ROOF LIVE LOAD OF 30 POUNDS PER SQUARE FOOT, MINIMUM

COLLATERAL LOAD OF 3 POUNDS PER SQUARE FOOT, MINIMUM

WITH WIND EXPOSURE "C"

DESIGN WIND SPEED, INCLUDING GUSTS, OF 90 MILES PER HOUR

OFFICE

A

SCALE: ƒ" = 1'0"

WALL TYPES

NOTES:

MINIMUM LENGTH TO BE 24" - BEVEL INSIDE CORNERS

PROVIDE „" X 4" HIGH VINYL BASE AT ALL INTERIOR WALLS

WITH R-13 BATT INSULATION

WITH †" TYPE "X" GYPSUM BOARD EACH SIDE

3†" - 16 GAUGE METAL STUDS @ 16" O.C.

ALL INTERIOR WALLS ARE TYPE "A" UNLESS NOTED OTHERWISE

IN THE WAREHOUSE

LINER PANELS ON INTERIOR OF EXTERIOR WALLS

PROVIDE SMOOTH INTERIOR METAL

GENERAL NOTES

DIMENSIONS AT GYPSUM BOARD WALLS ARE NOMINAL

ADDITIONAL CONSTRUCTION

REFER TO STRUCTURAL, MECHANICAL AND ELECTRICAL SHEETS FOR

FROM MANUFACTURERS STANDARD COLORS

ALL FINISHES TO BE SELECTED BY CONTRACTING OFFICER

SEE ADDITIONAL NOTES ON THE BUILDING SECTION

ENAMEL - EXTERIOR SPECIFIC FOR ALL EXTERIOR DOORS

PAINT ALL DOOR FRAMES WITH THREE COAT SYSTEM - GLOSS

PAINT ALL EXTERIOR DOORS WITH THREE COAT SYSTEM - GLOSS ENAMEL

PROVIDE NONSLIP SURFACE

OR APPROVED EQUAL ON CONCRETE FLOOR

PROVIDE 2 COATS OF CRYSTAL SEAL OTC BY DAYTON SUPERIOR

PRIOR TO APPLICATION OF CONCRETE SEALERS

SLAB SHALL BE CLEAN AND CLEAR OF OILS AND OTHER DELETERIOUS MATERIALS

PROVIDE CLEAR MATTE FINISH ON INTERIOR DOORS

FINISH COATS OF SEMI-GLOSS LATEX ON THE INTERIOR WALLS AND EXTERIOR FURR OUT

TEXTURED WITH KNOCK DOWN FINISH AND PAINTED WITH ONE COAT PRIMER AND TWO

PROVIDE 3†" 20 GAUGE METAL STUDS WITH †" TYPE "X" GYPSUM BOARD

WITH GLASS DOORS AND 10# ABC FIRE EXTINGUISHER (FE) PER NFPA 10

PROVIDE SURFACE MOUNTED STAINLESS STEEL FIRE EXTINGUISHER CABINETS

AT 9'0" ABOVE FINISH FLOOR IN OFFICE

PROVIDE 2 X 2 SUSPENDED ACOUSTICAL CEILING TILE

TYPICAL SIGNS

INTERIOR SIGNAGE

N.I.C.

R.C.P.

O.C.

DIA.

NOT IN CONTRACT

REFLECTED CEILING PLAN

ON CENTER

DIAMETER

GYP. BD. GYPSUM BOARD

GA. GAUGE OF METAL

MAX. MAXIMIN

MIN. MINIMUM

ABBREVIATIONS

AFF ABOVE FINISH FLOOR

CENTERED AT 5'0" ABOVE FINISH FLOOR

WITH THE ROOM NUMBER OR TITLE OF ROOM

MOUNT SIGNS ON THE WALL NEXT TO THE DOOR

COORDINATE WITH DPW FOR PLACEMENT

PROVIDE SIGN FOR OFFICE TO MATCH EXISTING

OFFSET LIGHT TOWARD LATCH SIDE OF DOOR 6'0"

EXCEPT THE MECHANICAL ROOM DOORS

PROVIDE 4'0" X 7'6" METAL CANOPY OVER ALL ENTRY DOORS @ 9'0"

REFER TO SITE PLAN - C1 FOR CONCRETE FLATWORK

PROVIDE NEW AS SHOWN (ALSO REFER TO CIVIL DRAWINGS)

REMOVE EXISTING CONCRETE STOOP AND STAIRS COMPLETE

FE

IN OFFICE AREA FINISHED TO MATCH TYPICAL WALLS

WITH †" TYPE "X" GYPSUM BOARD RUN TO 6" PAST SUSPENDED CEILING SYSTEM

PROVIDE 2•" 20 GAUGE METAL STUD FURR OUT ON EXTERIOR WALLS

L v

O f

A P

P R

D M

A D

E

D I

R E

C T

O R

A T

E

O F

U

B L I

C

W

R K

S

F O

R

L

O N

A

D

W

O D

M I

S S

O U

R I

D E

S C

R I

P T I

O N

R E

V I

S I

O N

S

D A

T E

G A

Y

B E

R

S

E D

B

A P

P R

O V

E D

D A

T E

S U

B M I

T T

E D

C H

E C

K E

D

D R

A W

N

D E

S I

G N

E D

C O

O R

D I

N A

T I

O N

D A

T E

D A

T E

D A

T E

SCALE

DATE

PROJECT NO:

DRAWING NO:

OFSHEET

AS SHOWN

E L

L E

E L

L E

E L

L E

G

B E

R T

S

C8030.22

A1 3

NORTH

048 8 24 FT16

SCALE: ‘" = 1'0"

SCALE: ‘" = 1'0"

D E

T A I

L S

F L

O

L

A N

F

N T

R A

L

I

S S

U E

A D

D I

T I

N

B

I

L D I

N G

22 OCT 15

MECH RM.

OFFICE

FE

WAREHOUSE

A

B

C

D

B

MEN

WOMEN

WAREHOUSE

OFFICE OFFICE OFFICE

104 105 106 A

FEFE

REMOVE THIS WALL COMPLETE

REMOVE FIRE RATED OVERHEAD DOOR COMPLETE

REMOVE EXISTING CONCRETE STAIRS COMPLETE

NORTH

048 8 24 FT16

SCALE: ‘" = 1'0"

SCALE: ‘" = 1'0"

FLOOR PLAN

AND FINISHES

OR CONSTRUCTION - PATCH SHALL MATCH EXISTING CONSTRUCTION

PATCH WALLS, FLOOR, AND CEILING WHERE DAMAGED BY DEMOLITION

REFER TO CONSTRUCTION DRAWINGS FOR EXTENT OF DEMOLITION

FOR ADDITIONAL DEMOLITION NOTES

REFER TO OTHER ARCHITECTURAL, MECHANICAL AND ELECTRICAL SHEETS

DEMOLITION NOTES

REMOVE EXISTING SOUTH EXTERIOR WALL COMPLETE

REEMOVE DOORS AND FRAMES, AND WALL FURR OUT COMPLETE

REMOVE EXISTING FIRE WALL AND FIRE RATED OVERHEAD DOOR COMPLETE

REMOVE EXISTING CONCRETE STAIR, HANDRAILS, AND OTHER ACESSORIES COMPLETE

DEMOLITION PLAN

EXTERIOR IS A METAL PANEL, PROVIDE R-11 BATT INSULATION

WITH †" TYPE "X" GYPSUM BOARD INTERIOR

2•" - 20 GAUGE METAL STUDS @ 16" O.C. B

B

A

A

A

WINDOW TYPES

NOT TO SCALE

A

HEAD AT 7'0" AFF.

ALUMINUM SLIDER

6'0" X 3'0"

A

PROVIDE 12" WIDE COUNTER OF SOLID SURFSACE MATERIAL

NO SCREEN ON INTERIOR WINDOW

THE USE OF AN EQUAL PRODUCT

BUT IS IN NO WAY INTENDED TO LIMIT

WINDOWS ARE BASED ON QUAKER WINDOW CO PRODUCTS

NOTES:

PROVIDE DRYWALL RETURNS AT HEAD AND JAMBS

BY THE CONTRACTING OFFICER FROM MANUFACTURERS STANDARDS

MINIMAL IMPACT TO THE SURFACE. COLOR SHALL BE AS SELECTED

BURNS MUST BE ABLE TO BE REMOVED BY SANDING WITH

CLEANERS; CLASS 1 CHEMICAL RESISTANCE; SEVERE STAINS AND

MATERIAL; EASY TO CLEAN AND UNDAMAGED BY COMMON HOUSEHOLD

COLOR AND PATTERN WHICH GOES ALL THE WAY THROUGH THE

MATERIAL SHALL BE A SOLID, NON-POROUS POLYMER WITH

EQULIVANCY WILL BE BASED ON THE FOLLOWING CHARACTERISTICS:

AS "CORIAN" AS MANUFACTURED BY E.I. DU PONT OR EQUAL.

COUNTER SHALL BE CONSTRUCTED OF A SOLID SURFACING MATERIAL SUCH

COUNTER AT WINDOW:

TEMPERED AND INSULATED GLASS

OFFICE

STORE LIGHTS FOR REINSTALLATION IN NEW SYSTEM

REMOVE EXISTING SUSPENDED CEILING SYSTEM IN OFFICES AND RESTROOMS COMPLETE

C.0004125

DPW 02643-5J

18'0"

A3

18'0"18'0"1'0"

59'0"

A2

AND AT DISSIMULAR MATERIALS INSIDE AND OUT

CAULK AROUND PERIMETER OF DOORS AND FRAMES

1'0"

3'6"

A

CONSTRUCT WALL TO COVER 'X' BRACING

ALL WALLS TO EXTEND TO THE UNDERSIDE OF THE ROOF

TO OPEN EXISTING SPACE TO ADDITION

REMOVE EXISTING END WALL AND 'X' BRACING COMPLETE

REMOVE EXISTING FIRE EXTINGUISHER CABINET IN MECHANICAL ROOM SAVE FOR RELOCATION

CUT AND GRIND ALL BOLTS WHERE THE CAGES WERE INSTALLED

BY REMOVING ROOF PANELS AND PROVIDING NEW

WHERE RADIANT HEATERS ARE REMOVED INFILL INTAKE/EXHAUST HOLES (4 TOTAL)

EXPANSION BOLTS COMPLETE

REMOVE ALL CAGE

EXPANSION BOLTS COMPLETE

REMOVE ALL CAGE

A

SIM.

EXTEND TO 10'0" AND PROVIDE GYPSUM BOARD RETURN ON TOP

SIMILAR TO TYPE 'A' WALL EXCEPT GYPSUM BOARD ON ONE SIDE

REFER TO MECHANICAL DRAWINGS

2-48" X 30" RETURN GRILLS

2016-07-01T12:31:53-0500
ROBERTS.GARY.L.1231307644