CONSTRUCTION NOTES
N O
R T
H
Q U A R T E R
M A S T E R
S T R E E T
E. SECOND STREET
NO SCALE
SERVICE LATERAL TRENCHING DETAIL
GRADE LEVEL
BELOW GRADE.
PLACE @ 12''
WARNING TAPE.
USE 6" OF 2" MINUS CRUSHED LIMESTONE.
CEREAL STRAW. IN AREAS WITH GRAVEL,
2 INCHES USING CLEAN AND MOLD FREE
MIXTURE. MULCH THE AREA TO A HEIGHT OF
PER 1000 SQUARE FEET USING A 13-13-13
SQUARE FEET. FERTILIZE AT A RATE OF 4 LBS
RYE AT A DENSITY OF 8 LBS PER 1000
OF 90% TURF TYPE TALL FESCUE AND 10%
SEED AFFECTED AREAS USING A MIXTURE
OF FILL SHALL CONSIST OF TOPSOIL.
ADJACENT SOIL. THE LAST 6 INCHES
AND COMPACT TO THE DENSITY OF
BACKFILL TRENCH IN 6 INCH LIFTS
2'-0"-SERVICE LATERAL
CHAIRS.
CONDUITS ARE PROVIDED, USE
OTHER DETAILS. WHERE MULTIPLE
AS INDICATED ON PLAN AND
CONDUIT AND CONDUCTORS
CONDUIT.
3000 PSI CONCRETE SURROUNDING
MINIMUM OF 3 INCHES OF
AND METER BASE
POLE WITH TRANSFORMERS
EXISTING LACLEDE ELECTRIC
EXTERIOR POWER NEW WORK
A P
P R
D M
A D
E
D I
R E
C T
O R
A T
E
O F
U
B L I
C
W
R K
S
F O
R
L
O N
A
D
O D
M I
S S
O U
R I
D E
S C
R I
P T I
O N
R E
V I
S I
O N
S
D A
T E
G A
Y
B E
R
S
E D
B
A P
P R
O V
E D
D A
T E
S U
B M I
T T
E D
C H
E C
K E
D
D R
A W
N
D E
S I
G N
E D
C O
O R
D I
N A
T I
O N
D A
T E
D A
T E
D A
T E
SCALE
DATE
PROJECT NO:
DRAWING NO:
OFSHEET
AS SHOWN
C.0004125
DPW 02643-5J
E2 6
F
N T
R A
L
I
S S
U E
A D
D I
T I
N
B
I
L D I
N G
N
R K
E X
T E
R I
W E
G G
A R
G G
A R
E L
L
C8030.22
22 OCT 15
S C A L E I N F E E T
402020 10
GROUND RING.
ADDITIONAL #4 COPPER CONDUCTOR FROM PANELBOARD 'MDP' GROUNDING BAR TO EXISTING
BAR AND SUPPLEMENT EXISTING #4 COPPER GROUNDING ELECTRODE CONDUCTOR WITH AN
MOVE EXISTING #4 GROUNDING ELECTRODE CONDUCTOR TO PANELBOARD 'MDP' GROUNDING
TO THE BUILDING IS APPROXIMATELY 55 FEET IN LENGTH.
OF EXISTING AND NEW SERVICE CONDUCTORS TO THE METER BASE. THE SERVICE LATERAL
USING A 50% OVERLAP. ELECTRIC UTILITY COMPANY WILL MAKE FINAL CONNECTION
ALL RGSC IN CONTACT WITH CONCRETE AND EARTH WITH A CORROSION RESISTANT TAPE
'MDP' AND TRANSITION TO CONCRETE ENCASED SCHEDULE 40 PVC BELOW GRADE. WRAP
TRENCHING DETAIL, THIS SHEET. USE RIGID GALVANIZED STEEL CONDUIT AT PANELBOARD
(PROVIDED BY EXTERIOR ELECTRICAL UTILITY) TO NEW PANELBOARD 'MDP'. SEE
CONDUIT, IN PARALLEL WITH EXISTING UNDERGROUND CONDUCTORS, FROM NEW METER BASE
PROVIDE ADDITIONAL (4)- 250 KCMIL, 600 VOLT, TYPE XLPE COPPER CONDUCTORS, IN 3"