8030_e1v8.pdf

PDF 241 KB Posted

Attached to
Metal Building Addition to Building 2327, Fort Leonard Wood, MO
Solicitation number
W911S7-16-B-0019
Issued by

About this file

Drawing 5 of 22

View the file

Other files

File Type Posted
W911S7-16-B-0019_Bid_Abstract.pdf PDF
W911S7-16-B-0019-0002_Addition_to_Building_2327.pdf PDF
Attachment_A _Statement_of_Work_Final_16-B-0019_Amendment_0002.pdf PDF
8030_c1v8rev.pdf PDF
Questions_and_Answers__W911S7-16-D-0019_Final.pdf PDF
8030_s1v8.pdf PDF
8030_e6v8.pdf PDF
8030_m2.pdf PDF
8030_mi4.pdf PDF
8030_e5v8.pdf PDF
8030_c1v8.pdf PDF
8030_a3v8.pdf PDF
8030_mi2.pdf PDF
Attachment_A _Statement_of_Work_Final_16-B-0019_Amendment_0001.pdf PDF
8030_e2v8.pdf PDF
DBA_Wage_Determination _19_August_2016.pdf PDF
8030_m3.pdf PDF
8030_m4.pdf PDF
8030_a2v8.pdf PDF
8030_mi3.pdf PDF
8030_a1v8.pdf PDF
8030_s2v8.pdf PDF
8030_s3v8.pdf PDF
W911S7-16-B-0019-0001_Addition_to_Bldg_2327 _Amendment.pdf PDF
8030_mi5.pdf PDF
8030_m1.pdf PDF
8030_mi1.pdf PDF
8030_e3v8.pdf PDF
8030_e4v8.pdf PDF
16-B-0019_Site_Visit_Roster.pdf PDF
Attachment_B _Drawings_16-B-0019.pdf PDF
DBA_Wage_Determination_MO160019_29_July_2016.pdf PDF
Attachment_A _Statement_of_Work_Final_16-B-0019.pdf PDF
W911S7-16-B-0019_Addition_to_Bldg_2327_Solicitation.pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WP

AFF

GFCI

RGSC

ABOVE FINISHED FLOOR

GROUND FAULT CIRCUIT INTERRUPTER

RIGID GALVANIZED STEEL CONDUIT

1.

2.

3.

4.

5.

FINISHED CEILINGS UNO.

CONCEAL ALL WIRING DEVICES AND BRANCH CIRCUITS INSIDE FINISHED WALLS AND ABOVE

6.

7.

10.

9.

8.

EMERGENCY BACKUP BATTERY.

PROVIDE AN ADDITIONAL UNSWITCHED PHASE CONDUCTOR TO ALL FIXTURES WITH AN

G

AT 24" AFF UNO. 'G' INDICATES GFCI RECEPTACLES.

RECEPTACLES SHALL BE IVORY IN COLOR AND HAVE AN IVORY COLORED FACEPLATE. INSTALL

120 VOLT, 20 AMP, SPECIFICATION GRADE, DOUBLE DUPLEX (QUAD) RECEPTACLE.

#12 AWG, 600 VOLT, THWN COPPER CONDUCTORS IN •" EMT UNO.

2' X 4' FLUORESCENT FIXTURE. SEE LIGHTING FIXTURE SCHEDULE FOR DETAILS.

FIXTURE SCHEDULE FOR DETAILS.

SINGLE FACE EXIT FIXTURE WITH RED LED LAMPS AND BATTERY BACKUP. SEE LIGHTING

THE WALL.

SEAL ALL PENETRATIONS OF WALLS WITH A FIREPROOF CAULK TO MATCH THE RATING OF

SM

LEGENDLEGEND

ABBREVIATIONS

GENERAL NOTES

MECHANICAL PLANS FOR ADDITIONAL REQUIREMENTS, IF ANY.

DISCONNECTING MEANS AND SHALL BE LOCATED WITHIN SIGHT OF EQUIPMENT. REFER TO

HORSEPOWER RATED 1 OR 2 POLE TOGGLE SWITCH WITH POSITIVE 'OFF'. SERVES AS RATED

NFPA 90A, NFPA 101 AND IEEE C2.

ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH NFPA 70, NFPA 72, NFPA 720, (CONTINUED)

S

S3

COLOR AND HAVE AN IVORY COLORED COVERPLATE. INSTALL @ 48" AFF UNO.

120/277 VOLT, 20 AMP, SPECIFICATION GRADE TOGGLE SWITCH. SWITCH SHALL BE IVORY IN

IVORY IN COLOR AND HAVE AN IVORY COLORED COVERPLATE. INSTALL @ 48" AFF UNO.

120/277 VOLT, 20 AMP, SPECIFICATION GRADE, 3 WAY TOGGLE SWITCH. SWITCH SHALL BE

INDICATES EXISTING TO REMAIN. BOLD LINE WEIGHT INDICATES NEW.

DASHED SYMBOLS INDICATE EQUIPMENT OR CIRCUITS TO BE REMOVED. SOLID, LIGHT LINE WEIGHT

WITH GROUND BUS. INSTALL AT 48" ABOVE FINISHED GRADE.

30 AMP, 240 VOLT, 2 POLE (SWITCHED) GENERAL DUTY, NEMA 3R, NON-FUSED DISCONNECT

11.

METAL HALIDE WALL MOUNTED EXTERIOR FIXTURE. SEE LIGHTING FIXTURE SCHEDULE FOR DETAILS.

PROVIDED IN DUAL GANG BOX WITH IVORY COLORED COVERPLATE. INSTALL AT 18" AFF UNO.

RJ-45 TYPE 568A DATA JACK (BLUE JACK WITH DATA LABELING). ONE OF EACH JACK SHALL BE (1)- RJ-45 TYPE 568A CATEGORY 6 VOICE JACK (WHITE JACK WITH VOICE LABELING) AND (1)-

3/4'' DIA. X 10' LONG COPPERCLAD STEEL GROUND ROD DRIVEN FULL DEPTH INTO THE EARTH.

VOLTAGE LAMP MOUNTING NOTESDESCRIPTIONTYPE

LIGHTING FIXTURE SCHEDULE

SINGLE FACE EXIT FIXTURE WITH LED LAMPS LED

DUAL HEAD EMERGENCY FIXTURE 120

2.

BEAM

SEALED

(2)-7.2 WATT

LIGHTING FIXTURE SCHEDULE NOTES:

1.

3.

A

4.

HID WALL MOUNT FIXTURE 120

T5 FLUORESCENT INDUSTRIAL HIGHBAY

B

DROP CEILING

INSTALL IN

13' AFF

SURFACE

120C

COOL WHITE

FLUORESCENT

(3)-T8

DROP CEILING

INSTALL IN

COOL WHITE

FLUORESCENT

(2)-T8

120 AT 9' AFF

CHAIN MOUNT

T8 FLUORESCENT CHAIN MOUNT

COOL WHITE

54 WATT

(6)-T5 HO

BOTTOM UNO

AFF TO FIXTURE

SURFACE 90''

COOL WHITE

FLUORESCENT

(2)-T8

@ 16' AFF

AIRCRAFT CABLE

STAINLESS STEEL

SUSPENDED BY

BATTERY BACKUP.

OR APPROVED EQUAL. FIXTURE WITH A SLASH SHALL BE PROVIDED WITH EMERGENCY

WIRE GUARD. THE FIXTURE SHALL BE A COLUMBIA LHR4-654-GWU-24EPU PLUS OPTIONS,

FIXTURE SHALL BE PROVIDED WITH A HIGH TEMPERATURE CLEAR ACRYLIC LENS AND FLAT

USE OF STAINLESS STEEL AIRCRAFT CABLES IN INVERTED 'Y' CONFIGURATION. THE

OF THE FIXTURE. THE FIXTURE SHALL BE MOUNTED TO THE CEILING THROUGH THE

FOR RIGIDITY. FINISH SHALL BE WHITE BAKED ENAMEL APPLIED AFTER FABRICATION

FIXTURE SHALL HAVE A HOUSING CONSTRUCTED OF COLD ROLLED STEEL, DIE-EMBOSSED

T8 FLUORESCENT PRISMATIC, AIR HANDLING TROFFER

COOL WHITE

FLUORESCENT

(2)-T8

D

1' X 4' FLUORESCENT WALL MOUNTED UPLIGHT/DOWNLIGHT

BASE OF FIXTURE

AT 7.5' AFF TO

WALL MOUNT

7.

8.

E

FLUORESCENT LAMPS

9" DIA. ARCHITECTURAL DOWNLIGHT WITH (2)- COMPACT 120

4100K

TRIPLE TUBE

(2)-32 WATT

IN CEILING

FLUSH MOUNT

HALIDE

START METAL

100 W PULSE

5.

6.

BUS. INSTALL @ 48" ABOVE FINISHED GRADE WITHIN SIGHT OF RTU-1 FOR SERVICE PURPOSES.

200 AMP, 240 VOLT, 3 POLE, HEAVY DUTY, NEMA 3R NON-FUSED DISCONNECT WITH GROUND

1' X 4' FLUORESCENT LIGHTING FIXTURE, EXISTING, TO REMAIN.

DUAL HEAD EMERGENCY FIXTURE WITH BATTERY BACKUP, EXISTING, TO REMAIN.

FOR THESE DROPS ARE GRAY.

EXISTING VSAT JACK TO REMAIN. SINGLE RJ-45 JACK IS BLACK. CAT 6 CABLES

EXISTING FIXTURE, TO REMAIN.

EXISTING FIXTURE, TO REMAIN.

EXISTING FIXTURE, TO REMAIN.

FIXTURE SHALL BE SINGLE FACE UNLESS OTHERWISE NOTED.

PREWIRED AND SHALL BE EQUIPPED WITH A SEALED LEAD CALCIUM BATTERY PACK.

HARDWARE SHALL BE FURNISHED WITH FINISH TO MATCH THE HOUSING. FIXTURE SHALL BE

AN INTEGRAL CLEAR POLYCARBONATE VANDAL RESISTANT FACE SHIELD. ALL MOUNTING

WITH A 3/4 INCH STROKE. STENCIL FACE SHALL HAVE BRUSHED ALUMINUM FINISH AND

IVORY LACQUER OR VINYL. ALUMINUM STENCIL FACE SHALL HAVE 6-INCH RED LETTERS

FIXTURE HOUSING SHALL BE OF EXTRUDED ALUMINUM. FINISH OF HOUSING SHALL BE

APPROVED EQUAL. WHERE INDICATED, FIXTURE SHALL BE OFFSET FROM DOORWAY.

BE RATED FOR WET LOCATIONS. MCGRAW-EDISON IST-100-MP-120-2S-BZ-L-P OR

TO 1. THE FIXTURE SHALL COME EQUIPPED WITH AN INTEGRAL PHOTOCELL AND SHALL

HALIDE LAMP. FIXTURE SHALL HAVE A SPACING TO MOUNTING HEIGHT RATIO OF 6

SHALL HAVE A MEDIUM BASE DESIGNED FOR AND EQUIPPED WITH A 100 WATT METAL

SHALL BE CAPABLE OF OPERATING FROM -20 DEGREES F TO 120 DEGREES F. FIXTURE

SHALL BE OF THE HIGH POWER FACTOR TYPE, RATED FOR 120 VOLT OPERATION, AND

RESISTANT TEMPERED FLAT GLASS HAVING A MINIMUM THICKNESS OF 1/8''. BALLAST

DARK BRONZE POLYESTER POWDER COAT. LENS SHALL BE CLEAR, HEAT AND IMPACT

CAPTIVE STAINLESS STEEL FASTENERS. HOUSING AND DOOR FRAME FINISH SHALL BE

CAST ALUMINUM HOUSING AND A REMOVABLE HINGED DOOR FRAME SECURED WITH TWO

FIXTURE SHALL BE DESIGNED FOR WALL MOUNTING. FIXTURE SHALL HAVE A ONE PIECE

A P

P R

D M

A D

E

D I

R E

C T

O R

A T

E

O F

P U

B L I

C

W

R K

S

F O

R

L

O N

A

D

W

O

M I

S S

O U

R I

D E

S C

R I

P T I

O N

R E

V I

S I

O N

S

D A

T E

G A

Y

B E

R

E D

B

A P

P R

O V

E D

D A

T E

S U

B M I

T T

E D

C H

E C

K E

D

D R

A W

N

D E

S I

G N

E D

C O

O R

D I

N A

T I

O N

D A

T E

D A

T E

D A

T E

SCALE

DATE

PROJECT NO:

DRAWING NO:

OFSHEET

AS SHOWN

C.0004125

DPW 02643-5J

E1

F

N T

R A

L

I

S S

U E

A D

D I

T I

N

B

I

L D I

N G

D E

T A I

N

H E

D U

L E

S

E L

E C

T R I

C

G E

N

G

G G

A R

G

G G

A R

E L

L

C8030.22

22 OCT 15

ENCLOSURE.

SERVICE EQUIPMENT. PROVIDE IN LOCATION SHOWN AND INSTALL AT 72 " TO TOP OF

NEW MDP, 600 AMPERE, 3 PHASE, 4 WIRE 208Y/120 WITH COPPER BUSSES AND RATED AS

DATA JACK IS BLUE IN COLOR. DUAL DATA JACKS IN DDC CABINET ARE BLUE.

EXISTING, DUAL CATEGORY 6 RJ-45 DATA JACKS (TYPE 568A). VOICE JACK IS WHITE AND

INSTALL NEW STATIONS AT 48" AFF.

ARCHITECTURAL PLANS FOR ADDITIONAL REQUIREMENTS. EXISTING SWITCH STATIONS REMAIN.

THREE-PUSHBUTTON SWITCH STATION FOR UP/DOWN/STOP CONTROL OF GARAGE DOORS. REFER TO

EXISTING DISCONNECT, TO REMAIN.

LESS THAN 3 FEET TO MOTORS AND OTHER HVAC EQUIPMENT.

CONDUITS SHALL BE RGSC OR SCHEDULE 40 PVC AS NOTED. SEALTITE MAY BE USED IN LENGTHS

SOME CONDUCTORS SIZES HAVE BEEN INCREASED FOR VOLTAGE DROP MITIGATION. EXTERIOR

CONDUCTORS SHALL BE AWG 12 600 VOLT TYPE THWN COPPER IN EMT UNLESS OTHERWISE NOTED.

REFER TO SHEET E6 FOR FIRE ALARM / MASS NOTIFICATION SYMBOLS LEGEND

THE NUMERALS, WHICH SHALL BE MARKED WITH PERMANENT BLACK INK.

AND ARC FLASH BOUNDARY: INCHES. LABEL SHALL BE COMMERCIALLY PRINTED EXCEPT FOR

INCLUDING SYSTEM VOLTAGE: 208, ARC FLASH BOUNDARY: ARC FLASH PPE CATEGORY:

OUTSIDE OF PANELBOARD 'MDP' SHALL BE LABELED FOR ARC FLASH AND SHOCK HAZARD WARNING, CONTRACTOR'S EXPENSE.

ASSOCIATED WITH LACK OF COORDINATION SHALL BE REMEDIED AT THE ELECTRICAL

COMPANY A MINIMUM OF SIX WEEKS PRIOR TO REQUIRING THEIR SERVICES. ANY PROBLEMS

ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE EXTERIOR ELECTRICAL UTILITY

SHALL BE BONDED TO THE BUILDING GROUNDING ELECTRODE CONDUCTOR.

ALL METALLIC CONDUITS, BOXES, WIRING DEVICES, ENCLOSURES, RACKS AND CABLE TRAY

TAPE USING A 50% OVERLAP.

RGSC IN CONTACT WITH THE EARTH SHALL BE WRAPPED WITH A CORROSION RESISTANT

GFCI AND INSTALLED AT 24" AFF.

SHALL BE INSTALLED AT 24" ABOVE FINISHED GRADE. ALL RECEPTACLES IN BAY SHALL BE

RATING WHETHER OR NOT A PLUG IS INSERTED. EXTERIOR WEATHERPROOF RECEPTACLES

GFCI AND 'WP' DENOTES CAST METAL WEATHERPROOF COVER WHICH MAINTAINS WET LOCATION

NUMERAL INDICATES CIRCUIT IN PANEL 'A' (TYPICAL, ALL RECEPTACLES). 'G' DENOTES

IVORY IN COLOR AND HAVE AN IVORY COLORED COVERPLATE. INSTALL @ 18" AFF UNO.

120 VOLT, 20 AMP, SPECIFICATION GRADE DUPLEX RECEPTACLE. RECEPTACLE SHALL BE

MOTOR OR EQUIPMENT UTILIZING MOTOR(S).

AND PROVIDE (4)- 250 KCMIL AND A # 2 GROUND FROM PANEL 'MDP' TO PANEL 'A'.

BRANCH BREAKER IN NEW PANEL 'MDP'. REMOVE THE BONDING JUMPER IN THIS PANEL

DISCONNECTED FROM THIS PANEL. THIS PANEL SHALL BE FED FROM A 250 AMPERE

EXISTING TWO SECTION POWER PANELBOARD. EXISTING SERVICE CONDUCTORS HALL BE

UNO UNLESS NOTED OTHERWISE

T8 FLUORESCENT, PRISMATIC TROFFER

EXISTING

MATCH

EXISTING FIXTURE TO REMAIN.

3 LAMP TYPE B AND C AIR HANDLING FIXTURES ARE TO REMAIN.

THROUGH THEM SHALL HAVE EMERGENCY BATTERY BACKUP. EXISTING 2 LAMP AND

ACRYLIC LENS. BALLASTS SHALL BE ELECTRONIC. FIXTURES WITH A SLASH

AFTER FABRICATION. THE FIXTURE SHALL BE EQUIPPED WITH A PRISMATIC

FABRICATED OF SHEET STEEL AND FINISHED IN WHITE BAKED ON ENAMEL APPLIED

WITH BLACK REVEAL, DESIGNED FOR MOUNTING IN A TEE GRID CEILING SYSTEM,

FIXTURE SHALL BE A RECESSED 2' X 4' STATIC (NON AIR HANDLING) TROFFER

2016-07-01T12:52:51-0500
ROBERTS.GARY.L.1231307644

File details come from the government source that posted it. Updated .