A-1
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
AND GENERAL NOTES
EXISTING/REMOVAL FLOOR PLAN
MANUFACTURES INDICATED.
PURPOSES ONLY. AND NOT INTENDED TO LIMIT SELECTIONS TO PRODUCTS OF THE
COLORS AND PATTERNS LISTED BY MANUFACTURES ARE FOR BIDDING IDENTIFICATION 1.
ADJACENT AREAS AS DIRECTED BY THE CONTRACTING OFFICER REPRESENTATIVE (COR).
CAUSED BY THIS PROJECT AND SHALL REPAIR THE DAMAGES TO MATCH UP TO
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES MADE TO EXISTING AREAS
FOR APPROVAL.
CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITION AND SUBMITED TO COR
CONDITION. IN THAT CASE, SHOP DRAWINGS SHALL BE PREPARED AT THE SITE BY THE
SOME DETAILS SHOWN ON CONTRACT DRAWINGS MAY NOT COINCIDE WITH THE FIELD
8.
FOR APPROVAL.
CONTRACTOR SHALL SUBMIT MANUFACTURER'S INSTALLATION SHOP DRAWINGS TO COR
2.
3.
4.
5.
6.
7.
CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER.
IF THERE ARE ANY CONFLICTS WITHIN THE CONTRACT DOCUMENT, THE GENERAL
AND DIMENSIONS PRIOR TO COMMENCING ANY CONSTRUCTION OR RENOVATION.
THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFYING ALL EXISTING CONDITION
OF THE LOAD BEARING WALLS TO PREVENT COLLAPSE OF THE STRUCTURE.
APPROPRIATE TEMPORARY SUPPORTS SHOULD BE CONSTRUCTED PRIOR TO DEMOLITION
9.
10.
11.
12.
13.
14.
DETAILS AND GET APPROVAL FROM COR. BEFORE FABRICATION AND INSTALLATION.
CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL DOOR/WINDOW
ADDITIONAL COST TO THE GOVERNMENT.
EQUIPMENT, ETC), ELECTRICAL, TELEPHONE AND FIRE ALARM SYSTEM WITHOUT
THE INSTALLATION AND/OR REPLACEMENT OF MECHANICAL (PLUMBING, HEATING,
ITEMS, CUT, PATCH AND RESTORE WALLS, FLOORS AND CEILING WHERE REQUIRED FOR
THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVE/REINSTALL ANY OBSTRUCTED
GENERAL NOTES
SPECIFICATION 15181.
ITEMS REQUIRING MAINTENANCE/OPERATION IAW THE SECTION 3.1.14, OMA STD
PROVIDE ACCESS DOORS FOR ALL CONCEALED VALVES, VENTS, CONTROLS AND OTHER
COMMENCEMENT OF FLOOR TILE WORK AND AS PER FLOOR FINISH SCHEDULE.
ALL CONCRETE FLOOR SURFACES SHALL BE LEVELED AND SMOOTHED PRIOR TO
OFFICE, DPW. PER DIRECTION FROM THE INSPECTOR IN CHARGE OR COR.
SALVAGE OR SERVICEABLE MATERIALS SHALL BE RETURNED TO SUPPLY OR STORAGE
SHALL BE AS A PART OF THE CONTRACT DOCUMENT OF THIS PROJECT.
STANDARD DETAIL DRAWINGS FOR O&MA PROJECT, KOREA, DATED OCTOBER 1, 2003
1.67 K. SM/W
3.34 K. SM/W
AS FOLLOWS :
WALL
ROOF
"R" VALUE FOR INSULATION SHALL BE
& COATING.
REMOVE & CLEAN EXISTING PAINT BY SAND PAPER/ GRINDING FOR NEW PAINTING
FROM THE MANUFACTURE SHOWING THE PRODUCT IS LEAD FREE.
A CERTIFICATE OR MATERIAL SAFETY DATA SHEET (MSDS), WRITTEN IN ENGLISH,
SOLIDS) DURING THE EXECUTION OF THIS PROJECT. THE CONTRACTOR WILL PROVIDE
COATINGS WITH LESS THAN 0.05 PERCENT LEAD BY WEIGHT OF THE NON-VOLATILE
THE CONTRACTOR IS REQUIRED TO USE "LEAD FREE" COATINGS (LIQUID PAINTS OR
15.
16.
17.
DOCUMENTATION TO 8 CES/CEAN.
THE CONTRACTOR SHALL PROVIDE THE NEW SURVEY REPORT AND ASBESTOS REMOVAL
ACCORDANCE WITH THE KOREA ENVIRONMENTAL GOVERNING STANDARD (KEGS).
PRIOR TO ANY WORK TO ASSURE THAT APPROPRIATE ASBESTOS CONTROL IS IN
AREA WILL NEED TO BE RESURVEYED AND ASBESTOS MATERIALS SHOULD BE REMOVED
WORK IN THE AFFECTED AREA AND NOTIFY THE CONTRACTING OFFICER. THE WORK
ASBESTOS CONTAINING MATERIAL ARE DISCOVERED, THE CONTRACTOR SHALL CEASE
IS NOT PRESENT IN THE AREAS AFFECTED BY THIS WORK: HOWEVER, IF SUSPECTED
VERIFYING THE PRODUCT IS ASBESTOS FREE. TESTS HAVE INDICATED THAT ASBESTOS
WILL PROVIDE A CERTIFICATE OR MSDS, WRITTEN IN ENGLISH, FROM THE MANUFACTURER
PERCENT BY WEIGHT) DURING THE EXECUTION OF THIS PROJECT. THE CONTRACTOR
THE CONTRACTOR IS REQUIRED TO USE "ASBESTOS FREE" MATERIALS (LESS THAN 0.1
SCALE: 1/100
EXISTING/REMOVAL FLOOR PLAN
S
S
4,67423,9774,267
32,918
,4
,8
,8
,0
,0
,2
,6
,3
,6
,4
,9
,2
,6
LEGEND
REMOVE DOOR & WINDOW
REMOVE GWB WITH METAL STUD
REMOVE CONC SLAB
(BLDG S-2399)
ARCHITECTURAL
1.
2.
ASBESTOS CONTAINING MATERIAL REMOVED FROM THE WORK SITE.
THE CONTRACTOR SHALL SUBMIT A CERTIFICATION OF DISPOSAL TO COR FOR EVERY LOAD
3.
TO COMPLETE REMOVAL ACM AT THE WORK SITE.
THE CONTRACTOR SHALL CONTACT AND VERIFY TO ENVIRONMENTAL OFFICE THRU COR
AGENCY, KOREA REGION OFFICE.
DATED 14 JANUARY 2014, ISSUED BY THE DEPARTMENT OF THE ARMY, INSTALLATION MANAGEMENT
CONTROL ACTIVITIES, STANDARD TECHNICAL SPECFICATIONS FOR OMA PROJECTS, KOREA",
THE ASBESTOS REMOVAL WORKS SHALL CONFIRM TO "SECTION 02 82 14/ASBESTOS HAZARD
ACM NOTES
CAMP CASEY
REPAIR BUILDING S-2399,
YI, SC
160851
A-2
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
SLAB IF NEEDED.
CORRECTED FOR NEW FLOORING. PROVIDE LEVELING CONCRETE FOR EXISTING CONCRETE
CONCRETE, LOW SPOTS, HIGH SPOTS, PAINTING, AND UNEVEN SURFACE SHALL HAVE BEEN
SHALL BE SMOOTH, TRUE, LEVEL PLANE WITH ALL DEFECTS SUCH AS ROUGH OR SCALING
ON FLOOR PLAN & INTERIOR FINISH SCHEDULE. THE EXISTING CONCRETE FLOORING
REPLACE DETERIORATED EXISTING FLOOR TILE WITH NEW PVCT INCLUDING VCB AS SHOWN
FINISH AS SHWON ON FLOOR PLAN, SECTIONS AND FINISH SCHEDULE.
APPLY EPOXY COATING ON EXISTING CONCRETE SLAB INCLUDING NON SLIP ABRASIVE GRAIN
SHOWN ON FLOOR PLAN, ROOF PLAN AND SECTIONS.
VAPOR/AIR BARRIER, PROTECTED METAL FLASHING, AND METAL ROOF DECK, PURLIN AS
REPLACE DETERIORATED EXISTING ROOF WITH NEW BUILT UP ROOFING INCLUDING INSULATION, SCALE: 1/100
NEW GROUND FLOOR PLAN
AND SCOPE OF WORK
NEW GROUND FLOOR PLAN
AND ELEVATIONS
REPLACE DETERIORATED EXISTING CONCRETE STOOP WITH NEW AS SHWON ON FLOOR PLAN
SHOP AREA
MECH ROOM
A-4
A-4
D6D6D6D5
D5 D6 D6 D6
FEC
FEC
S
S
EWC
4,67423,9774,267
32,918
,4
,8
,8
,0
,0
,2
,6
,3
,6
,4
,9
,2
,6
LATRINE
WOMEN'S
LATRINE
MEN'S
VEST
J/C
TOOL ROOM
W1
W2
W1
W1
W1
W1
D1
D8 D1
D7
D2
D4
D3
D2
D10
D11
D11
A-4
A-4
ROOM
LAUNDRY
OFFICE
INSPECTOR
OFFICE
FOREMAN
OFFICE
SHOP CONTROL
L/SW WD
WILL BE REMAINED (TYP)
EXST VEHICLE LIFT
A-5
A-5
BB
STORAGE
EQUIPMENT
D
W1
W1
FEC
FEC
(TYP)
CONC STOOP
(TYP)
CONC STOOP
(TYP)
ON INSULATION W/VR
WALL LINER PANEL
PROTECTED MTL
D8
D8
D9
1. FLOOR WORK
REPAIR / MAINTENANCE (K) WORK
SCOPE OF WORK (ARCHITECTURAL WORK)
SECTION AND INTERIOR FINISH SCHEDULE.
REPLACE EXISTING CONCRETE SLAB AS SHOWN ON FLOOR PLAN, EXISTING/REMOVAL PLAN,
1.1
1.2
1.3
1.4
1.5
INSULATION AS SHOWN ON FLOOR PLANS, SECTIONS AND DETAIL DRAWINGS.
REPLACE DETERIORATED EXISTING ALL GWB WALLS WITH NEW INCLUDING METAL STUDS AND
2. INTERIOR & EXTERIOR WALL WORK
2.1
2.2
2.3
2.4
2.5
AND DETAIL DRAWINGS.
OF GWB FOR NEW MECHANICAL PIPING SYSTEM AND DUCT AS PER FLOOR PLANS, SECTIONS
REPLACE EXISTING PIPE CHASES / PIPE COVER WITH NEW CMU, WATERPROOF OR X TYPE
SHOWN ON FLOOR PLANS AND SECTIONS.
COATS, WATER PROOF MEMBRANE, PLASTERING W/METAL LATH AND WATERPROOF GWB AS
REPLACE DETERIORATED EXISTING GCWT(FULL HEIGHT) WITH NEW INCLUDING CEMENT BOND
SHOWN ON INTERIOR FINISH SCHEDULE AND SECTION.
PAINT ON ALL INTERIOR/EXTERIOR WALL SURFACES INCLUDING OTHER COMPONENTS AS
3.4
3.2
3.3
3.1
3. INTERIOR & EXTERIOR CEILING/ROOF WORK
3.5
SECTION.
PAINT ON ALL INTERIOR CEILING SURFACES AS SHOWN ON INTERIOR FINISH SCHEDULE AND
FLOOR PLAN AND ELEVATIONS.
PAINT ALL EXISTING EXTERIOR EXPOSED METAL, WOODS, FASCIA AND SOFFIT AS SHOWN ON
FLOOR PLAN AND SECTIONS.
APPLY ACRYLIC FLUID-APPLIED WATERPROOFING COATING ON EXISTING ROOF AS SHOWN ON
4.1
4.3
4.4
4.5
4.2
4. MISC. WORK
REPLACE DETERIORATED EXISTING WINDOW HORIZONTAL MINI BLINDS WITH NEW, FIREPROOF TYPE.
SETS AS SHOWN ON NEW FLOOR PLAN AND DOOR SCHEDULE.
REPLACE DETERIORATED EXISTING DOORS AND DOOR FRAMES WITH NEW INCLUDING HARDWARE
AND WINDOW SCHEDULE.
THERMAL BREAKER TYPE WINDOWS INCLUDING GLASS AS SHOWN ON FLOOR PLANS, ELEVATIONS
REPLACE DETERIORATED EXISTING WINDOWS INCLUDING INSECT SCREEN WITH NEW ALUMINUM
PLANS AND DETAIL DRAWING.
REPLACE DETERIORATED EXISTING METAL SHELF WITH MOP RACK WITH NEW AS SHOWN ON FLOOR
ON FLOOR PLANS AND DETAIL DRAWING.
REPLACE DETERIORATED EXISTING FIRE EXTINGUISHERS CABINETS(FEC) WITH NEW AS SHOWN
PLANS AND DETAIL DRAWINGS.
REPLACE DETERIORATED EXISTING ALL TOILET ACCESSORIES WITH NEW AS SHOWN ON FLOOR
PLAN AND DETAIL.
REPLACE DETERIORATED EXISTING SST LAUNDRY SHELVES WITH NEW AS SHOWN ON FLOOR
4.6
4.7
PROOF MEMBRANE, MORTAR BED AS SHOWN ON FLOOR PLANS AND DETAIL DRAWINGS.
REPLACE DETERIORATED EXISTING FCT WITH NEW INCLUDING CEMENT BOND COAT, WATER
SECTIONS AND DETAIL DRAWINGS.
REPLACE DETERIORATED EXISTING CANOPY WITH NEW AS SHOWN ON FLOOR PLANS, ELEVATIONS, 3.6
PLAN AND SECTIONS.
REPLACE DETERIORATED EXISTING PROTECTED ROOF LINER PANEL WITH NEW AS SHOWN ON FLOOR
2.6
BLANK INSULATION AND VAPOR RETARD AS SHOWN ON FLOOR PLAN AND SECTIONS.
REPLACE DETERIORATED EXISTING PROTECTED WALL LINER PANEL WITH NEW INCLUDING WALL
AS SHOWN ON FLOOR PLANS AND ELEVATIONS.
BLOCK UP EXISTING DOOR, WINDOW, DUCT AND LOUVER OPENING WITH CMU, RE-BAR AND EIFS
LEGEND
BLOCK UP OPENING W/200THK CMU
200 THK MET STUD WALL
150 THK MET STUD WALL
(BLDG S-2399)
ARCHITECTURAL
CAMP CASEY
REPAIR BUILDING S-2399,
A-3
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
SCOPE OF WORKS (ARCHITECTURAL WORKS)
REPAIR / MAINTENANCE (K) WORKS
DS DS
R O
O F
S L
O P
E
P
R
DS DS
R O
S
O P
P
R
ROOF SLOPE
1 PER 12
ROOF SLOPE
1 PER 12
GEJ
DS
DS
DS
GEJ
GEJ
DS
DS
GEJ
DS
LEGEND
(TYP)
METAL GUTTER
PROTECTED
PROTECTED METAL GUTTER
(TYP)
NATURAL DAYLIGHT
CLEAN EXISTING
ROOF
EXISTING METAL
BUILT-UP ROOFING
PROTECTED METAL ROOF (TYP)
WATERPROOFING ON EXISTING
APPLY ACRYLIC FLUID-APPLIED
NEW ROOF PLAN
SCALE: 1/100
DS
DS
AND LOUVER SCHEDULE.
REPLACE DETERIORATED EXISTING ALUMINUM LOUVER WITH NEW AS SHOWN ON FLOOR PLANS
PAINT EXISTING GUARD POSTS AS SHOWN ON FLOOR PLAN AND ELEVATIONS.
4.8
4.9
4. MISC. WORK
4.10
SCHEDULE.
REPLACE INTERIOR & EXTERIOR SIGNAGES WITH NEW FOR ALL ROOMS AS SHOWN ON SIGNAGE
4.11
4.12
4.13
(TYP)
METAL CANOPY
PROTECTED
(TYP)
METAL CANOPY
PROTECTED
DRAWINGS.
CONCRETE SPLASH BLOCKS AS SHOWN ON FLOOR PLANS, ELEVATIONS, SECTIONS AND DETAIL
REPLACE DETERIORATED EXISTING RAIN GUTTERS AND DOWNSPOUTS WITH NEW INCLUDING
4.14
WITH NEW AS SHOWN ON FLOOR PLANS AND SECTION.
REPLACE DETERIORATED EXISTING STEEL POST AND SAFETY CHAIN AROUND INSPECTION PIT
REPLACE BULLETIN BOARDS WITH NEW AS SHOWN ON FLOOR PLANS AND DETAIL DRAWINGS.4.15
DETAIL DRAWING.
CASING HOOD AND ACCESSORIES AS SHOWN ON FLOOR PLAN, PICTURE, DOOR SCHEDULE AND
STEEL ROLL UP DOORS INCLUDING MOTORS, EMERGENCY MANUAL CHAINS, STEEL GUIDE RAILS, REPLACE DETERIORATED EXISTING ROLL UP DOORS WITH NEW THERMAL INSULATED GALVANIZED
ELEVATIONS.
CLEAN EXISTING NATURAL DAYLIGHTS AND CLERESTORY AS SHOWN ON ROOF PLAN AND
4.16
ELEVATION AND DETAIL DRAWINGS.
REPLACE DETERIORATED WINDOW GUARD AT TOOL ROOM WITH NEW AS SHOWN ON FLOOR PLAN,
4.17
PLAN, SECTION AND DETAIL DRAWINGS.
REPLACE DETERIORATED STEEL GRATING COVER AT INSPECTION PIT WITH NEW AS SHOWN ON FLOOR
4.18 REPLACE DETERIORATED CHAIN LINK FENCE WITH NEW ON SUB-BUILDINGS AS SHOWN ON PICTURES.
(TYP)
& METAL FLASHING
INSULATION ON AIR BARRIER
BUILT-UP ROOFING ON RIGID
(SEE MECH DWG)
GOOSENECK
FAN (SEE MECH DWG)
EXISTING EXHAUST
(BLDG S-2399)
ARCHITECTURAL
NEW ROOF PLAN AND SCOPE OF WORK
4.19 REMOVE EXISTING ACM AS BELOW IN BUILDING S-2399, CP CASEY.
- DUCT INSULATION: 120SF IN MECHANICAL ROOM
- CAULK AROUND CMU: 4LF IN MALE LATRINE
- WHITE PIPE FITTING INSULATION: 1EA IN MECHANICAL ROOM
CAMP CASEY
REPAIR BUILDING S-2399,
A-4
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
SCALE:
SOUTH ELEVATION
1/100 SCALE:
NORTH ELEVATION
1/100
SCALE:
WEST ELEVATION
1/100 SCALE:
EAST ELEVATION
1/100
1 2
3 4
(TYP)
GUTTER
METAL
PROTECTED
WALL (TYP)
EXISTING CMU
PAINT
(TYP)
NATURAL DAYLIGHT
CLEAN EXISTING
WALL (TYP)
EXISTING CMU
PAINT
PROTECTED METAL ROOF (TYP)
WATERPROOFING ON EXISTING
APPLY ACRYLIC FLUID-APPLIED
PROTECTED METAL ROOF (TYP)
WATERPROOFING ON EXISTING
APPLY ACRYLIC FLUID-APPLIED
(TYP)
& METAL FLASHING
INSULATION ON AIR BARRIER
BUILT-UP ROOFING ON RIGID
(TYP)
GUTTER
METAL
PROTECTED
(TYP)
BLAST METAL DOOR
THERMAL INSULATED
(TYP)
SLIDING WINDOW
INSULATED AL BLAST
(TYP)
SLIDING WINDOW
INSULATED AL BLAST
(TYP)
NATURAL DAYLIGHT
CLEAN EXISTING
PAINT EXISTING
GUARD POST (TYP)
(TYP)
CONC STOOP
(TYP)
CONC STOOP
(TYP)
CONC STOOP
WALL (TYP)
EXISTING CMU
PAINT
(TYP)
BLAST METAL DOOR
THERMAL INSULATED
(TYP)
& METAL FLASHING
INSULATION ON AIR BARRIER
BUILT-UP ROOFING ON RIGID
GUTTER(TYP.)
METAL
PROTECTED
METAL SIDING (TYP)
PAINT EXISTING PROTECTED
CLERESTORY
CLEAN EXISTING
DOWNSPOUT
METAL
PROTECTED
(TYP)
GUARD POST
PAINT EXISTING
DOOR (TYP)
OVERHEAD COILING
(TYP)
BLAST METAL DOOR
THERMAL INSULATED
PAINT EXISTING
GUARD POST (TYP) (TYP)
DOWNSPOUT
METAL
PROTECTED
& SPLASH BLOCK (TYP)
PROTECTED METAL DOWNSPOUT
W/REBAR
WINDOW OPENING
BLOCK UP
GUAD POST (TYP)
PAINT ON EXISTING
(TYP)
BLAST METAL DOOR
THERMAL INSULATED
GUARD
WINDOW
SCALE:
PICTURES
N/A
ELEVATIONS AND PICTURES
(TYP)
ALL EXTERIOR WALL
PAINT EAVES, FASCIA &
PROTECTED METAL ROOF (TYP)
WATERPROOFING ON EXISTING
APPLY ACRYLIC FLUID-APPLIED
PROTECTED METAL ROOF (TYP)
WATERPROOFING ON EXISTING
APPLY ACRYLIC FLUID-APPLIED
(TYP)
ALL EXTERIOR WALL
PAINT EAVES, FASCIA &
W/DOOR
CHAIN LINK FENCE
,6
,6
7,300 7, 3, W/DOOR
CHAIN LINK FENCE
7,300L X 7,200W X 2,600H
BUILDING DEMENSION:
5,900L X 3,000W X 2,600H
BUILDING DEMENSION:
5,900
CANOPY (TYP)
PROTECTED METAL
CANOPY (TYP)
PROTECTED METAL
(TYP)
DOWNSPOUT
PROTECTED METAL
CANOPY (TYP)
PROTECTED METAL
CANOPY (TYP)
PROTECTED METAL
(TYP)
PROTECTED METAL SIDING
CLEAN & PAINT EXISTING
W/REBAR
WINDOW OPENING
BLOCK UP
(BLDG S-2399)
ARCHITECTURAL
CAMP CASEY
REPAIR BUILDING S-2399,
A-5
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECH ROOM
SHOP AREA
POINT
WORKING 1
SHOP AREA
1/100
LONGITUDINAL SECTION
SCALE:
1/100
CROSS SECTION
SCALE:
POINT
WORKING 4
12(TYP)
PROTECTED METAL SIDING
CLEAN & PAINT EXISTING
WALL (TYP)
EXISTING CMU
PAINT DOOR (TYP)
OVERHEAD COILING
ON EXISTING CONC SLAB
EPOXY COATING
ON EXISTING CONC SLAB
EPOXY COATING
,8
,3
0(TYP)
& METAL FLASHING
INSULATION ON AIR BARRIER
BUILT-UP ROOFING ON RIGID
PROTECTED METAL ROOF (TYP)
WATERPROOFING ON EXISTING
APPLY ACRYLIC FLUID-APPLIED
PROTECTED METAL ROOF (TYP)
WATERPROOFING ON EXISTING
APPLY ACRYLIC FLUID-APPLIED
(TYP)
COLUMNS & BEAMS
ON EXISTING STL
PAINT
(TYP)
COLUMNS & BEAMS
ON EXISTING STL
PAINT
PAINT EXISTING
GUARD POST (TYP)
CLERESTORY WINDOW
CLEAN EXISTING
SECTIONS
ON EXISTING CRANE
PAINT
OFFICE
SHOP CONTROL
AIR PIPE
COVER OF EXHAUST
REMAIN & CLEAN
PAINT ALL EXIST WALL
GRATING COVER
REPL. STEEL
PAINT ON EXIST STL LADDER
DIA SAFETY CHAIN
REPL EXIST 5 mm
SCALE: 1 : 25
INSPECTION PIT SECTION
SCALE: 1 : 25
STEEL LADDER
PAINT ON EXIST
TRACK AND CURB
INTEGRAL STEEL
PAINT ON EXIST
PIPE POST (TYP)
REMOVABLE STEEL
EPOXY FINISH
EPOXY FINISH
PIT CROSS SECTION
PAINT ALL EXIST WALL
A-9
A-9
(TYP)
ON EXST INSULATION
ROOF LINER PANEL
PROTECTED MTL
(TYP)
W/INSULATION & VR
WALL LINER PANEL
PROTECTED MTL
(TYP)
W/INSULATION & VR
WALL LINER PANEL
PROTECTED MTL
(TYP)
ON EXST INSULATION
ROOF LINER PANEL
PROTECTED MTL
PIPE POST (TYP)
REMOVABLE STEEL
NON-SLIP NOSING
EXIST METAL
CLEAN
(BLDG S-2399)
ARCHITECTURAL
CAMP CASEY
REPAIR BUILDING S-2399,
KWON, CH
A-6
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECH ROOM
POINT
WORKING
POINT
WORKING
SCALE:
WALL (TYP)
EXISTING CMU
PAINT
TO REMAIN (TYP)
EXISTING CONC SLAB
(TYP)
& METAL FLASHING
INSULATION ON AIR BARRIER
BUILT-UP ROOFING ON RIGID
ON CONC
EPOXY COATING
1A
COILING DOOR
OVERHEAD
INSULATED
1B
ON CONC
EPOXY COATINGCONC APRON
EXISTING
1A
1B
4,978
,8
,3
A-8
A-8
(TYP)
PROTECTED METAL SIDING
PAINT ON EXISTING
PROTECTED METAL ROOF (TYP)
WATERPROOFING ON EXISTING
APPLY ACRYLIC FLUID-APPLIED
PROTECTED METAL ROOF (TYP)
WATERPROOFING ON EXISTING
APPLY ACRYLIC FLUID-APPLIED
S
S
W WD
EXST BOLLARD
PAINT ON
SCALE:
EXTERIOR WALL SECTION
1/50
AS SHOWN
SCALE:
EXTERIOR WALL SECTION
1/50
SCALE: 1/20
104 107
FT ON CEMENT BOND COAT
SCHEDULE
FINISH PER
ON CEMENT MORTAR BED
ON WATER-PROOFING
1C
INTERIOR WALL SECTION
FL
LATRINE
MEN'S
OFFICE
SHOP CONTROL
CMU BLOCK
PAINT ON
(TYP)
INSULATION ON AIR BARRIER
BUILT-UP ROOFING ON RIGID
SCHEDULE
FINISH PER
ON 200T MTL STUD
ON 15T WATERPROOF GWB
ON METAL LATH WITH PLASTERING
ON WATERPROOFING MEMBRANE
GCWT ON CEMENT BOND COAT
1C
A-8
KEY PLAN
SCALE: 1/20
1D
EXTERIOR WALL SECTION
,1
(TYP)
INSULATION ON AIR BARRIER
BUILT-UP ROOFING ON RIGID
1D
A-8
(TYP)
EXTERIOR WALL ONLY
90T MTL STUD @
W/INSULATION ON
PAINT ON 15T GWB
CEILING (TYP)
PAINT ON EXST CONC
PVCT
(TYP)
CONC STOOP
WALL (TYP)
PAINT ON CONC OR CMU
1E
A-8
,1
,3
SCALE: 1/20
1E
EXTERIOR WALL SECTION
INTERIOR/EXTERIOR WALL SECTIONS
(TYP)
INSULATION ON AIR BARRIER
BUILT-UP ROOFING ON RIGID
(TYP)
EXTERIOR WALL ONLY
90T MTL STUD @
W/INSULATION ON
PAINT ON 15T GWB
CEILING (TYP)
PAINT ON EXST CONC
(TYP)
INSULATED BLAST WINDOW
(TYP)
INSULATED BLAST DOOR
WALL (TYP)
PAINT ON CMU
(TYP)
ON INSULATION W/VR
WALL LINER PANEL
PROTECTED MTL
(TYP)
ON EXST INSULATION
ROOF LINER PANEL
PROTECTED MTL
(TYP)
ON INSULATION W/VR
WALL LINER PANEL
PROTECTED MTL
ON EXST INSULATION (TYP)
ROOF LINER PANEL
PROTECTED MTL
(BLDG S-2399)
ARCHITECTURAL
EXTERIOR / INTERIOR WALL SECTIONS
CAMP CASEY
REPAIR BUILDING S-2399,
A-7
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
INTERIOR ELEVATIONS (LATRINE 104 )
SCALE: 1/50
LAV
TOILET ACCESSORYABBREV.
ACCESSORY MOUNTING HEIGHT SCHEDULE
WALL MTD LAVATORY
QUANTITY
SEE ELEVS & PLANS
SEE ELEVS & PLANS
SEE ELEVS & PLANS
SEE ELEVS & PLANS
REMARKS
SEE ELEVS & PLANS
STANDING
MG MIRROR GLASS 1100
SD SOAP DISPENSER
PTDWR PAPER TOWEL DISPENSER W/ RECEPTACLE
EWC ELECTRIC WATER COOLER
WC WATER CLOSET
381~432
TTD TOILET TISSUE DISPENSER 800
UR URINAL 430 SEE ELEVS & PLANS
SEE ELEVS & PLANS
* PAPER HOLE
PERSON
* 1015
(TO RIM)
(BTM)
(BTM)
(TO RIM)
(INDIVIDUAL
LAV-BTM)
(TOP SEAT)
1/2
MIRROR DETAILS
SCALE :
3B
NOT TO SCALE
DETAIL "A"
1/10 "A"
SCALE:
3A
FRONT ELEVATION
RUBBER BACKING
RUBBER LINER
2 - EACH SIDE
FASTENER
FACE OF WALL
W/ PIN KNOT SCREWS
1.2 THK 12x12 SST FRAME
BOLTS 2 - EACH SIDE
FRAME FASTENED W/ 6 DIA
PLATE GLASS MIRROR
1.2 THK 12x25 GALV STL
4B
4A
SCALE AS NOTED
ELEVATION
435X1420X190
WALL OVERALL SIZE
GCWT FINISH
VERIFY DIMENSION
NOTE
W/MFR PER SPEC
1/5
(2-PER SIDE)
6 DIA MET SCREW
4B
SCALE:
WOOD SHIM
(ALL AROUND)
TO REMAIN
EXISTING CMU WALL
W/ METAL LATH
CONC FILL
SCALE: 1/50
ENLAGED PARTIAL FLOOR PLAN
SCALE : AS SHOWN
PAPER TOWEL DISPENSER W/RECEPTACLE
S
S
4,877
2,9631,914
,2
,8
,4
,2
,1
,4
,1
,5
4,877
2,9631,914
A
D
C
B
A
SMLD
URINAL
SCREEN
MIRROR (TYP)
LAV
B
TP
TTD
PTDWR
,9
,7
,7
C
WC
GCWT-1 (TYP)
TTD TTD
D
DOOR TO
SHOP AREA
,7
,9
,9
SD UR
SCREEN
URINAL
SCALE:
SST BRACKET
OR EXP BOLTS TO
MATCH BRACKET
1/5
5C
SST SHELF
"A"
"A
SECTION "A"-"A"
1/2
W/ 2 - 6 DIA TOGGLE BOLTS
SCALE:
SCALE:
5B
5A 1/5
P L A N
ELEVATION
SMLD DETAILS
SCALE: AS SHOWN
SECTION
(BLDG S-2399)
ARCHITECTURAL
INTERIOR ELEVATIONS AND DETAILS
ENLARGED PARTIAL PLAN,
CAMP CASEY
REPAIR BUILDING S-2399,
A-8
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
METHODS
ELEVATION
2A
SECTION
2B
2B
@ 300 OC FOR TOP SHELF
FASTENING
OF WALL
18 GA SST SHELF
SST MOP HOLDER
NEEDED CENTER BRACKET
BRACKET W/2-6 DIA
2-16 GA SST SHELF
TOGGLE BOLTS & 1600
@ 300 OC FOR TOP SHELF
SST HOOK
HOOK
MOP HOLDER
SST SHELF BRACKET DRYING ROD
MOP RACK DETAILS
1/5
SCALE :
SCALE :
1/10
SPLASH BLOCK DETAIL
DOWNSPOT HANGER DETAILS
SCALE: 1/5
FRONT 12 LOWER
THAN BACK (MIN)
GUTTER LAP
ENDS
GUTTER
MET
SLOPE
A
A
SLOPE
1/16 PER FT
SECTION A-A
1/16 PER FT
SLOPE
CONTINUOUS
EXISTING
GUTTER
RIVET &
SOLDER
METAL ROOFING
EXISTING PROTECTED
*NOTE
1. DISTANCE BETWEEN GUTTER EXPANSION JOINTS
SHOULD NOT BE EXCEEDED MAX 12,000mm.
CLEAT
DOWNSPOUT
CENTER OF
DOWNSPOUT
PROTECTED METAL
BASE FLASHING
PROTECTED MET
PROTECTED
METAL
"Z" CLOSURE
100 THK TREATED
WD NAILER
80x80x7.0THK STEEL
ANGLE FRAME
@ 850 OC
METAL STRAP HANGER
@ 900 OC (MAX)
(RIVER TO GUTTER EDGE)
PROTECTED MET GUTTER
(SEE INTO BRACKET
HANGER)
25 W x 3 THK
BRACKET HANGER @
900 OC(MAX)
(STAGGERED W/
STRAP HANGERS)
PROTECTED MET
SOFFIT
C-100x50x20x2.3
W.P
STANDING SEAM
METAL ROOFING
CANOPY
EAVE FL
ASHING
T
15THK STL PLATE
1/10
SCALE:
OR METAL
EXST CMU
METAL DOOR PULL
(OUTSIDE TRIM DIM)
O
U T S
ID
R
IM
D
IM
METAL TRIM
GLASS
METAL FIRE
(ALL AROUND)
FLOOR FINISH
LINE
FINISH AS
SCHEDULED
WOOD SHIM
METAL DOOR
PULL
114@ 6" CMU WALL
@ 8" CMU WALL
CONC FILL
8" CMU WALL
(INSIDE BOX DIM)
(OUTSIDE TRIM DIM)
METAL DOOR
PULL
(ALL AROUND)
WOOD SHIM
CONC FILL
A
A
CEMENT MORTARSCREW (3-PER
SIDE)
W/METAL LATH
CONC FILL
@ 200 CMU WALL
89@ 150 CMU WALL
SCALE: N/A
5B
SECTION "A-A"
5C
ELEVATION
5A
PLAN
FIRE EXTINGUISHER CABINET DETAILS - 2
CANOPY DETAIL
*NOTE
1.
CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR APPROVAL.
SLOPE OF CANOPY SHALL BE MET FIELD CONDITION AND
50X12 MM HORIZONTAL
BARS @300 O.C. MAX.
WINDOW
WALL
@100 O.C.
OR OTHER TYPE OF
SCREWS OR BOLTS
& EXPANSION SHIELDS
FASTENINGS
75 ROUND BARS
@100 O.C.
(TYP.)
BARS @300 O.C. MAX.
50X12 MM HORIZONTAL
WINDOW OPENING
(TYP.)
(TYP.)
(TYP.)
N/A
SCALE :
WINDOW GUARD
ELEVATION
1A
SECTION
1B
(BLDG S-2399)
ARCHITECTURAL
DETAILS-1
CAMP CASEY
REPAIR BUILDING S-2399,
5 2
(10 % MIN)
GROOVE CUT VENT
GUTTER
PROTECTED MET
PROTECTED MET
DOWNSPOUT
EDGE NAILERS
TREATED WD
2-Tx250
STRIP FLASHING
BITUMEN STOP
ORGANIC MEMBRANE
ON 3-PLY BUIL-UP ROOFING
MINERAL SURFACE CAP SHEET
ON INSUL ON VR
EXISTING CONC
SLAB TO REMAIN
SIDING TO REMAIN
EXISTING METAL
BASE FLASHING
PROTECTED MET
(M
IN
M
IN
TREATED
WOOD CANT
EXISTING CONC
WALL TO REMAIN
TREATED WOOD
NAILER W/ GROOVE
CUT VENT (20% MIN)
W/ 9 DIA EXP
1A 1B
BOLTS @ 900 OC (MAX)
12 DIA EXP
CONC EAVE DETAIL WALL FLASHING DETAIL
M
IN
0(M
IN
1C VENT THRU ROOF DETAIL
EXISTING CONC
SLAB TO REMAIN
ON 3-PLY BUIL-UP ROOFING
MINERAL SURFACE CAP SHEET
ON INSUL ON VR
TREATED
WOOD CANT
NAILER W/ 12 DIA
TREATED WD
Tx150
@ 1200 OC (MAX)
12 DIA EXP BOLT
1/5
SCALE :
BUILT UP ROOF DETAILS
SCHEDULE
AS PER FINISH
N.T.SSCALE:
,0
TRACK AND CURB
INTEGRAL STEEL
PAINT ON EXIST
SCALE: N.T.S
STEEL GRATING COVER
BARS @ 150 mm O.C.
20 mm x 3 mm STL CROSS
EXIST STEEL ANGLE
REMAIN AND CLEAN
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A-9
SCALE:
10MM THK PEJ
150MM CWB
D13
CONCRETE STOOP
N.T.S
1% SLOPE
150200
NFSM
EXISTING CONC SLABW/BROOM FINISH
W.W.F & 150MM CWB
ON GRADE W/150X150-#8
150MM THK. CONC STOOP
2.0 THK SST SHELF
SUPPORT FRAME @ 800 O.C
@ EACH SUPPORT FRAME
FACE OF WALL
SCALE: 1/5
SST SHELF DETAIL @ LAUNDRY
O O
R
250 200
SCALE: N/A
4B SECTION
ELEVATION4A
BULLETIN BOARD DETAIL
BULLETIN BOARD
FL
25x50 OAK FRAME
1,200
,1
PIPE POST (TYP)
REMOVABLE STEEL
38MM DIA
(TYP)
SAFETY CHAIN
5MM DIA STEEL
PAINT ON
REMOVABLE STEEL PIPE POST
SAFETY CHAIN AND
W/ 6 DIA EXP BOLTS
BULLETIN BOARD
(SEE MATERIAL SCHEDULE
(HEAD & SILL)
3 THK METAL CLIP
@ 450 OC
O O
R
CMU WALL
25x50 OAK FRAME
BB-1 , A-10)
(BLDG S-2399)
ARCHITECTURAL
CAMP CASEY
REPAIR BUILDING S-2399,
KWON, CH
DETAILS-2
A-10
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
I N T E R I O R F I N I S H S C H E D U L E
COATING
GYPSUM WALL BOARD
GLAZED CERAMIC WALL TILE
AL ALUMINUM
BUILDING
CEILING
COLOR
BLDG
CLG
CLR
DR DOOR
FNSH FINISH
CONC CONCRETE HGT
GWB
GCWT
MECH MECHANICAL
HEIGHT
PAINTP
CONCRETE MASONRY UNITCMU
CERAMIC MOSAIC TILECMT
FLOORSFLS
REPLACEREPL
INSULATION
EXTERIOREXT
ACST ACOUSTICAL TILE SSM SOLID SURFACE MATERIAL
PLASTIC LAMINATEDPL
EXISTINGEXST
MATERIALMATL
EXPOSED CONCEC
SF STEEL FRAME
STL STEEL
NUMBERNO
ELECTRICALELEC M MAN
REPAIR BY REPLACINGRBR
VINYL COMPOSITION TILE
VINYL COVE BASE
VCT
VARIOUSVAR
VCB
W/O WITHOUT
WITHW/
VAPOR RETARDERVR
WOMENW
CEILING MATERIAL / COLOR
M A T E R I A L C O L O R S C H E D U L E
FLOOR MATERIAL / COLOR
BASE MATERIAL / COLOR
VCB-1
BB-1
MISC MATERIAL / COLOR
* GROUT COLOR FOR GCWT
P-3 P-4
P-1
WALL MATERIAL / COLOR
P-2ECS-1
MB-1
TP-1
EXST RBR NEW
MATL
FNSH CLR
FLOOR BASE
EXST NEW
FNSH CLR
WAINSCOT
MATL
EXST NEW
FNSH CLR HGT
INSIDE OF EXT WALL
MATL
EXST NEW
FNSH CLR
INTERIOR WALL
MATL
EXST NEW
FNSH CLR
CEILING
MATL
EXST NEW
FNSH CLR HGT
REMARKS
ECS COATING
CONC
ECS
VCT
ECS ECS
ECS
ECS
ECS
PVCT
PVCT
ECS-1
PVCT-1
100 HGT
PAINT
100 HGT
PAINT
CONC
ECS
GWB
GWB
GWB PAINT
PAINT
PAINT
PAINT
E X T E R I O R F I N I S H S C H E D U L E
A B B R E V I A T I O N S
ROOF
WALL
DOOR/ DOOR FRAME
DOWNSPOUT
GUTTER/ FLASHING
PROTECTED METAL ROOF COATING -
CMU - -
PAINT
RC-1
1) BACKGROUND COLOR
1) BACK GROUND COLOR
BY DPW
EXST RBR NEW
MATERIAL
FNSH COLOR REMARKSSURFACES
METAL - -
PROTECTED METAL
PROTECTED METAL
PROTECTED METAL
PROTECTED METAL
PAINT 1) TRIM COLOR
VCT PVCT GWB GWB PAINT
SHOP AREA
MECH ROOM
RM
NOS
ROOM NAMES
RBR RBR RBR RBR RBR
CMT
PVCT
ECS
MATL
100 HGT
PAINT
ECS-1
ECS-1
ECS-1
ECS-1
CONC ECS112 ECS-1
CMU
/GWB
VCB
VCB
VCB VCB
VCB
VCB
VCB-1
CMU
/GWB
CMU
/GWB
P-3
P-3
P-3
100 HGT
PAINT
P-3
VCB-1
VCB-1
- 2240
GWB PAINT
PAINTGWB
P-1
P-1
P-1
P-1
P-1
P-1
P-1
CMU
CMU
CMU PAINT
PAINT
PAINT
PAINT
PAINT
PAINT
PAINT
PAINT
P-1
P-1
P-1
P-1
P-1
P-1
P-1
P-1
1)P-4
CMU
CMU
CMU
CMU
CONC
CONC
PAINT
1)PAINT
CONC
P-2
1)P-4
CONC VAR
VAR
CONC
PAINT P-2 VAR
PAINT P-2 VAR
PAINT
PAINT
BUILT-UP ROOFING BUILT-UP ROOFING - - - -
PROTECTED METAL - - PAINT 1) BACKGROUND COLOR
1) BACK GROUND COLOR
BY DPW
1) TRIM COLOR BY DPW
1) TRIM COLOR 1) TRIM COLOR BY DPW
1) TRIM COLOR 1) TRIM COLOR BY DPW
: VINYL COVE BASE
DARK BROWN
100 HGT x 3 THK
OR APPROVED EQUAL
: BULLETIN BOARD
THE MOON CO,
TAN NUCORK TACKBOARD
W/ 50 WIDE NATURAL OAK TRIM
SIZE - 1200(W) x 900(H) OR
APPROVED EQUAL: MOLD & MILDEW RESISTANT,
STAIN PROOF WHITE
OR APPROVED EQUAL
: MOLD & MILDEW RESISTANT,
STAIN PROOF, WHITE
OR APPROVED EQUAL
: PAINT
LATEX / SEMI-GLOSS
NOROO, #NR9059
OR APPROVED EQUAL
: PAINT
ALKYD, SEMI-GLOSS
FOR EXISTING STL COLUMN,
BEAM, PURLIN, GIRTS, CRANE FRAME
NOROO, #NK7073
OR APPROVED EQUAL
: PAINT
LATEX / SEMI-GROSS
NOROO, #NR7073
OR APPROVED EQUAL
: PAINT
NOROO, #NR7066
OR APPROVED EQUAL
: EPOXY COATING SYSTEM
LIGHT GREY (APPROVED BY USER)
OR APPROVED EQUAL
: MINI BLIND @ WINDOW
HANKOOK BLIND,
25mm WIDE ALUMINUM, 1V-22500
OR APPROVED EQUAL
: TOILET PARTITION & URINAL SCREEN
SST, SATIN FINISH
W/ETCHING PATTERN BY MFR
OR APPROVED EQUAL
F.F
F.F
F.F
F.F
COATING
COATING
F.F
F.F
F.F
* GROUT COLOR FOR FCT
GWB
GCWT
-CMU
GWB
GWB
GWB
GWB
AND MATERIAL & COLOR SCHEDULE
INTERIOR, EXTERIOR FINISH SCHEDULE
/CMU
MTL
INSUL
/INSUL
MTL
/INSUL
CMU P-1
INSPECTOR OFFICE -
-CONC
LATEX/GROSS
PAINT P-2
PAINT P-2
PAINT P-2
P-2
P-2
P-4 : PAINT
ALKYD, SEMI-GLOSS
FOR EXISTING STL COLUMN,
BEAM, PURLIN, GIRTS, CRANE FRAME
NOROO, #NK7073
OR APPROVED EQUAL
WOMEN'S LATRINE - - - - /GWB
GCWT
F.F GCWT-1
/CMU
GCWT
GCWT F.F GCWT-1 PAINT P-2 VAR
PAINT P-2 VAR
- - - - - -- - - -104 CMT -F.F GCWT -CONC- - - - /GWB
GCWT
F.F GCWT-1
/CMU
GCWT
GCWT F.F GCWT-1 PAINT P-2 VARMEN'S LATRINE
VEST COATING CMU
PAINT
100 HGT
- - - - - PAINT P-1 CONC -
JANITOR CLOSET
P-3
/GWB
CMU
CONC -
-CONC
CONC -
/GWB*
GWB* : WATER RESISTANT TYPE
OFFICE
SHOP CONTROL
PVCT-1
VAR
VAR
VAR
VAR
VAR
FOREMAN OFFICE PVCT-1
TOOL ROOM COATING
CMU
/GWB
PAINT
100 HGT
P-3
EQUIPMENT STORAGE
LAUNDRY ROOM -
CMU
/GWB
- GWB* : WATER RESISTANT TYPE
PRL
PURLIN, GIRTS, CRANE FRAME
1)FOR EXISTING STEEL COL, BEAM,
FS 595B 23617
SAND-STONE,
ROOF LINER PANEL
PROTECTED METAL
PWL
PAINT
F.F/
/P-1
PWL-1
PWL
F.F PWL-1
PWL
/F.F
PAINT
PWL-1 -
F.F PRL-1
FS 595B 23617
SAND-STONE,
WALL LINER PANEL
PROTECTED METAL PWL-1 :
PRL-1 :
OR APPROVED EQUAL
457.2MMx457.2MM, 3MM THK
KCC SENSE TILE, CERAMIC, TN2412C
PVC TILEPVCT-1 :
FCT
FCT
FCT-1
FCT-1
OR APPROVED EQUAL
NON-SLIP, 300 x 300 x 8 THK
FG 7L67-1, MARON
DONGSEO, INUS
NON-SLIP CERAMIC FLOOR TILEFCT-1 :
OR APPROVED EQUAL
300 x 600 x 10 THK
LQR 1N92-1, GLOSS
DONGSEO, INUS
GLAZED CERAMIC WALL TILEGCWT-1 :
2.
1.
FOR SUBMITTAL REQUIREMENTS AND SPECIFIC ITEMS TO BE PAINTED.
SCHEDULE. SEE SPECIFICATION SECTION 09915 : EXTERIOR AND INTERIOR COLOR SCHEDULE
COLOR DESIGNATION SHALL BE AS INDICATED IN THE EXTERIOR AND INTERIOR FINISH COLOR
WITH THE CAMP CASEY EXTERIOR COLOR SCHEME AS APPROVED BY THE COR.
SELECTION OF EXTERIOR PAINT AND FACTORY APPLIED COLORS SHALL BE IN ACCORDANCE
MANUFACTURERS STANDARD MUST APPROACH.
COLOR IS NOT REQUIRED. THE SELECTIONS SERVE ONLY TO INDICATE THE COLOR WHICH THE
INTENDED TO LIMIT SELECTIONS OF PRODUCTS. AN EXACT MATCH OF THE MANUFACTURERS
MANUFACTURERS' COLORS LISTED ARE FOR IDENTIFICATION PURPOSES ONLY AND ARE NOT 3.
4.
USER AGENCY.
SELECTION OF INTERIOR PAINT AND FACTORY APPLIED COLORS SHALL BE APPROVED BY
SHALL BE WATERPROOF TYPE GWB.GWB FOR TOILETS, AND OTHER WET AREAS 5.
FINISH SCHEDULE NOTES
VCB F.F VCB-1
/GWB
CMU
/GWB*
PRIMER, DHDC-6500P, 0.157KG/M2
TOP COAT, DHDC-6500T, 0.175KG/M2
& SLICA-10.6KG/M2
MID COAT, DHDC-6500M, 1.758KG/M2
NOROO PAINT
(BLDG S-2399)
ARCHITECTURAL
CAMP CASEY
REPAIR BUILDING S-2399,
A-11
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
DOOR HOOD
E
OVERHEAD COILING
THERMAL INSULATED
METAL OVERHEAD COILING
DOOR/WINDOW/LOUVER SCHEDULE
MATERIAL
FRAME
ROUGH OPENING
HEIGHTWIDTH WIDTH HEIGHT THICK
DOOR DIMENSION
SET
HDW
NO
UNDER
CUT
LOUVER
(HR)
FIRE
RATED
REMARKS
DOOR
NO
DOOR
TYPE
DOOR
LIGHT
VISION
UL LISTED
D4
D3
D2
D7
D5
D6
D1 21831015 2133914A - - -
MET DOOR
THERMAL INSULATEDB
METAL HOLLOW
CORE DOOR
A
E
E
C
MET 44.5MET
MET
MET
21831625 2133 44.51525
MET
MET
METMET
A METMET
2133 ----
B METMET ---
HINGES A5111 114x114, NRP
FLUSH BOLTS L04081
HINGES A5111 114X114, NRP
CLOSER CO2021
KICK PLATE J102, SST
EXIT DEVICE TYPE-1,
HINGES A5111 114X114, NRP
1 KICK PLATE J102, SST
1 ASTRAGAL
1 DOOR STOP L02161
HINGES A5111 114x114
CLOSER C02011
PULL PLATE J401
KICK PLATE J102, SST
PUSH PLATE J3011
DOOR STOPS L021611
HINGES A5111 114x114
CLOSERS CO20111
KICK PLATES J102, SST1
THRESHOLD J321001
HDW-1
HDW-2
HDW-3
HDW-5
HDW-9
W/ METAL FRAME
THRESHOLD J321001
METMET 44.5
W/ METAL FRAME
W1 ALGLASS -11171220 -- - - - --
1 CLOSER CO2021
2 KICK PLATES J102, SST
H A R D W A R E S C H E D U L E
LOCKSET 1000-1, F071
HDW-8
DOOR/WINDOW/LOUVER TYPES
SCALE: 1/5
S E C T I O N
HOOK &
EYEBOLT
DOOR
STEEL PLATE
WELDED TO
STEEL TUBE
CONCRETE
FOUNDATION
175x175x6THK
STOOP
CONCRETE
DOOR
50x50x6THK.
STEEL TUBE
WELDED TO
STEEL PLATE
250 SQ
DARK BROWN
80MMx80MMx3.2MM
THK. GALV. STEEL
TUBE (FILLED W/
WHITE STRIPS
CONC.)
P L A N
80MMx80MMx3.2MM THK
BUMPER L02101
WALL TYPE BUMPER L02101
HOOK & EYEBOLT
STEEL TUBE
(FILLED W/ CONC)
50x50x6 THK STEEL
GALV STEEL TUBE
PLATE WELDED TO
BACKGROUND
WALL TYPE
C ---
5486 5486 1) 1) 1)
1) 1) 1)
METMET
METMETD
4267 4876
1) BY DOOR MFR
1) BY DOOR MFR
A
C
D8
D9
44.5 5
F
DOOR W/ METAL FRAME
METAL BLAST RESISTANT
THERMAL INSULATED
: 40.6 KPA
- PEAK IMPULSE
: 210 KPA-MS
PRESSURE
- PEAK REFLECTED
(ANODIZED DARK BRONZE)
AL BLAST WINDOW
(THERMAL BREAK TYPE)
SLIDING
W/ INSECT SCREEN
- PEAK REFLECTED PRESSURE
: 40.6 KPA
- PEAK IMPULSE
: 210 KPA-MS
F
DOOR STOPS L021611
CLOSERS CO20111
KICK PLATES J102, SST1
THRESHOLD J321001
HDW-4
& ACCESSARIES.
DOOR MFR INCLUDING LOCKING DEVICE
ALL HARDWARE SHALL BE PROVIDED BY
KEY BOX : WALL MOUNTED KEY BOX E83512.
COORDINATING WITH THE USER FOR APPROVAL BY COR.
THE CONTRACTOR SHALL SUBMIT MASTER KEYING CHART, 3.
4.
5.
7.
6.
HEAT GAIN AND FIRERATED.
WHITE OR LIGHT BEIGE TO MAXIMIZE REFLECTANCE AND MINIMIZE
BE EQUIPPED WITH HORIZONTAL MINI BLINDS. COLOR SHALL BE
WINDOWS IN ALL AREAS WHERE FUNCTIONALLY WARRANTED SHALL
1.
INSECT SCREEN SHOULD BE EQUIPPED TO ALL EXTERIOR WINDOWS.
FABRICATION AND INSTALLATION
SHALL BE APPROVED BY THE CONTRACTING OFFICER BEFORE
DOORS AND ALUMINUM WINDOWS AS ACTUAL SIZE, AND DRAWINGS
THE CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL
DOOR & WINDOW NOTES
HIGH QUALITY AND GRADE PRODUCTS WITH APPROVAL TO COR.
& QUALITY ARE NOT REQUIRED. BUT CONTRACTOR SHOULD INSTALL
AN EXACT MATCH OF THE MANUFACTURERS FUNCTION, GRADE, COLOR,
AND ARE NOT INTENDED TO LIMIT SELECTIONS OF PRODUCTS.
MANUFACTURERS LISTED ARE FOR IDENTIFICATION PURPOSES ONLY
( SHGC : MAX 0.4 )
+ 6 THK TINTED LOW-E TEMPERED GLASS
+ 12 THK AIR SPACE
: 8.75 THK CLEAR LAMINATED GLASS
TYPICAL INSULATED/LAMINATED GLASS FOR WINDOWS
THREE-BUTTON CONTROL STATION "OPEN-CLOSE-STOP"
ELECTRIC SENSING EDGE (SAFETY/WEATHER)
1.
2.
3.
OPERATION & EMERGENCY
MANUAL CHAIN)
ROLL UP DOOR NOTES
HARDWARE SCHEDULE & NOTES
DOOR / WINDOW SCHEDULE, ELEVATIONS,
C METMET 2230810 2133 44.5712 ----9D11
C METMET 2230810 2133 44.5712 ---8D10
PANEL AS
GLASS VISION
SCHEDULE
600x600
100x600
8.75 T + 5 + 4
1) INSULATED GLASS,
21831015 914
100X60
8.75 T + 5 + 4
1) INSULATED GLASS, 44.5213321831015 914
213391421831015 1HRS
D
TO DOOR (300 LG)
W/2 THK SST PLATE WELDED
300(UPPER LEAF)
METAL DOOR
FIRE RATED
FLAT ASTRAGAL
(LOWER LEAF)
METAL DOOR
FIRE RATED
TO DOOR
PLATE WELDED
2 THK SST
HDW-7
CLOSER CO20111
LOCKSET 1000-1 F042
HINGES 5112 114X1144
(LEVER TYPE HANDLE)
1 THRESHOLD J32100
FLAT ASTRAGAL @ UPPER LEAF
KICK PLATE J102 SST
TO RELEASE THE DOOR HOLDER)
TO SMOKE DETECTOR OR FIRE ALARM SYS
(DOOR HOLDER SHALL BE CONNECTED
@UPPER LEAF (ELECTRIC POWER REQD)
TYPE C00011 (WALL MTD)
ELECTRO MAGNETIC DOOR HOLDER,
1 DOOR STOP L02161 @ LOWER LEAF
44.5213391421831015 1HRS-
44.5213391421831015 1HRS-
1HRS
THRESHOLD J321001
DOOR STOPS L021611
LOCKSET 1000-1 F04
HINGES A5111 114x114
CLOSERS CO20111
KICK PLATES J102, SST1
THRESHOLD J321001
HDW-6
EXIT DEVICE TYPE-1,
HINGES A5111 114x114
W2 ALGLASS -6091016 -- - - - --F FIX
THRESHOLD J321001
WEATHERSTRIP & SEAL
THRESHOLD J321001
HEAD/JAMB:R0Y154, PEMKO-S88
SILL:R3B435, PEMKO-315N
WEATHERSTRIP & SEAL
HEAD/JAMB:R0Y154, PEMKO-S88
SILL:R3B435, PEMKO-315N
WEATHERSTRIP & SEAL
HEAD/JAMB:R0Y154, PEMKO-S88
SILL:R3B435, PEMKO-315N
DOOR STOP & HOLDER
DOOR STOP & HOLDER
DOOR STOP & HOLDER
MOTOR OPERATION, EMERGENCY HAND CHAIN WITH WEATHERSTRIPPING.
THERMAL INSULATED GALVANIZED STEEL ROLL UP DOOR WITH ELECTRIC
DOOR STOP & HOLDER DETAIL
DOOR & TRACK (ELECT. POWER
METAL HOLLOW CORE DOOR
FUNCTION 08, LEVER TYPE
FUNCTION 08, LEVER TYPE
(LEVER TYPE HANDLE)
(LEVER TYPE HANDLE)
(LEVER TYPE HANDLE)
(LEVER TYPE HANDLE)
LOCKSET 1000-1, F07
LOCKSET 1000-1 F01
(BLDG S-2399)
ARCHITECTURAL
CAMP CASEY
REPAIR BUILDING S-2399
A-12
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
SIGNAGE PLAN AND SCHEDULE
SIGN
TYPE
WALL DOOR
REMARKNO.
TYPE
MESSAGE
CLG
S I G N A G E S C H E D U L E
MOUNTING
A
SIGNAGE PLAN
SCALE:
BUILDING IDENTIFICATION
COORDINATED WITH THE CONTRACTING
BY THE CONTRACTOR
OFFICER AND USING AGENCY
2. SIGN MESSAGE COPY WILL BE
NOTES:
"HELVETICA MEDIUM"
1. LETTER TYPE SHALL BEEQ EQ
V E
R
IF
Y
H G
T 70
FIN FL
MISC IDENTIFICATION
IDENTIFICATION
MISC
NOTE : FOR ALTERNATE MESSAGE
SEE SIGNAGE SCHEDULE
CENTER OF
SIGNAGE
OFFICE IDENTIFICATION
SEE SIGNAGE
SCHEDULE
FOR LOCATION
EQ.EQ.
AS SHOWN SIGNAGE PLAN.
ROOM NUMBERS SHALL BE
NOTE
FIN FL
CENTER OF
SIGNAGE
3A
1. BUILDING IDENTIFICATION NUMBER
; CONTRACTOR SHALL VERIFY NUMBER, COLOR, SIZE1ST FL
IDENTIFICATION
BUILDING
NUMBER
AND HGT OF LOCATION WITH DPW
2. NOS. ARE TWO PLACES PER EACH BUILDING.
3. SEE ELEVATION FOR LOCATION.
NOTE
BY DPW
LETTER COLOR
BY DPW
COLOR
BACKGROUND
3B
BUILDING IDENTIFICATION
BACKGROUND
POLISH EDGES
BLUE
WHITE LETTERS
(SEE SPECS)
T
C A P
ALL AROUND
RAISED
POLISH EDGES
ALL AROUND
(12 CAP
BACKBOARD
ON WHITE
LETTER HGT)
BLACK LETTERS
INSERT PANEL
BACKGROUND
STANDARD BROWN
WHITE LETTERS
(SEE NOTE)
3A
POLISH EDGES
ALL AROUND
(12 CAP
BACKBOARD
ON WHITE
LETTER HGT)
BLACK LETTERS
INSERT PANEL
BACKGROUND
STANDARD BROWN
WHITE LETTERS
(SEE NOTE)
T
C A P
MASTIC COMPOUND
6 THK AL PL
8 PER SIGN
AL SLEEVE
6 DIA STAINLESS
STEEL BOLT
EXISTING BLDG TO REMAIN
N/A
SCALE:
SIZE & MOUNTING LOCATION OF SIGNAGE
N/A SCALE:
N/A
MOUNTING DETAILS
2A 2B
2C
3A 3B
OF HEADER SECTION AND
BACK SPLAYED WITH ENAMEL
ACRYLIC W/GRAPHIC
APPLIED TO REVERSE SIDE
2 THK CLEAR MATTE
FINISH WALL
POLISH EDGES ALL AROUND
ACRYLIC SPACER
1 THK CLEAR
(COLOR-SEE SIGNAGE
10 THK MATE ACRYLIC
TYPE & DETAILS)
(COLOR-SEE SIGNAGE
TYPE & DETAILS)
FOAM TAPE
DOUBLE EMULSION
225150 225
12 12
S-2399
SHOP AREA
MECH ROOM
S
S
104106
LATRINE
WOMEN'S
LATRINE
MEN'S
J/C
TOOL ROOM
ROOM
LAUNDRY
OFFICE
INSPECTOR
OFFICE
FOREMAN
OFFICE
SHOP CONTROL
STORAGE
EQUIPMENT
FEC
A
A
SHOP CONTROL OFFICE
TOILET & SYMBOL
JANITOR CLOSET
INSPECTOR OFFICE
FOREMAN OFFICE
TOOL ROOM
EQUIPMENT STORAGE
LAUNDRY
S-2399
STORAGE ROOM
EQUIPMENT
EXISTING CMU WALL
(BLDG S-2399)
ARCHITECTURAL
CAMP CASEY
REPAIR BUILDING S-2399,